HomeMy WebLinkAboutPermit M14-0195 - SUMMIT SURGICAL - ROOFTOP GAS PACK UNITSUMMIT SURGICAL 613 INDUSTRY DR M14-0195 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 2523049008 Permit Number: M14-0195 Address: 613 INDUSTRY DR Issue Date: 10/24/2014 Permit Expires On: 4/22/2015 Project Name: SUMMIT SURGICAL Owner: Name: BLUE DOG PROPERTIES TRUST Address: PO BOX 847 C/O THOMSON REUTERS PTS, CARLSBAD, WA, 92018 Contact Person: Name: INNA BUCKWALTER Phone: (206) 512-9647 Address: 1916 220 ST SE STE M101, BOTHELL, WA, 98021 Contractor: Name: PACIFIC AIR CONTROL INC Phone: Address: 1916 220TH ST SE SUITE M101, BOTHELL, WA, 98021 License No: PACIFAC230P8 Expiration Date: 10/1/2015 Lender: Name: Address: , , , DESCRIPTION OF WORK: REPLACE EXISTING 4-TON ROOFTOP GAS PACK UNIT WITH NEW GAS PACK 4-TON UNIT, LIKE FOR LIKE WITH APPLICABLE CURB ADAPTER, ECONOMIZER AND BAROMETRIC RELIEF. Valuation of Work: $6,680.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $285.10 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2014 2012 Permit Center Authorized Signature: Date: IO(2-141Li, I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name Date: (0/21//d Z/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0705 0701 MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKW. _.4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: oil$ 1 D/l3 // (/ y 1(3 1/5 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 2523 C;)/ —9oo Site Address: ;; /3 /1/ ` 7"4s DR I ve— 7U JkLL1/LC% //f Suite Number: Floor: Tenant Name: � 4-4 7)7/7)/ T 3 1(2. New Tenant: ❑ Yes ® .. No PROPERTY OWNER Name:4/CWP ANDOVeR pXearl 1/ePi} J i99t Address: S ID NW MARSNALLS ST 4/3DD City: POKFLAND State: OR Zip:g720 CONTACT PERSON - person receiving all project communication Name: INNA BuckwA L/1 e Address: 191b 22 1 S+ SE /VI of City: 13 - He LL State: k A Zip: 98621 Phone: 2_06 .-5/2-96 07 Fax: 206 3 LD" 2 2 7D Email: / NAM 8 @ P/ cfFICA// con tROL. Ca r, MECHANICAL CONTRACTOR INFORMATION Company Name: PAC [FI C A I R C0/v' RDL, l'C Address: ( 8 I (, Z 20m si-s E S' /lam/ /Q/ City: EcyibeLL State: 1,r,,,A. Zip: 9s'02) Phone: 206 682`63as Fax: 206 -3 z/0 22 70 Contr Reg No.: P/ C 1 FFC23O P8Exp Datc: I Ohf 1S Tukwila Business License .: 13LI S ---Deg STh9 031.601i_9 o7 Valuation of project (contractor's bid price): $ 6 R© Describe the scope of work in detail: RePt_ACE. EXIST/VG Zi-rlN POOF7Z P GAS PACk LON/T //77-/ NeW CAS PACK /i/V/7-; L/kE FOR LIKe WITH APPL/CAP Le. CURB AbApleR, ECnNd4/Zede A4vt 81\2OM eTk i c R-e -PF, Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement [] Fuel Type: Electric ❑ Gas NI Other: IL. Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-1 1 .docic Revised August 2011 hh Page 1 of 2 • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > I ook btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment (RCOP- OF Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 . ► E : ! R AU - ORIZED AGENT: Signature: Print Name: /NNA 81,16k�i� Lfe Mailing Address: 1816 220/-1) J / SE S/e M/O/ Date: /0//0//y Day Telephone: 2o 17 8oeLL City WA- 98102/ State Zip H:Applications'.Forms-Applications On Line,201 I Applications,Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS P„erinitTR Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 5? 14=019 dress: 613=INDUSTRY Df pn 252304900E 85.. MECHANICAL $274.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $54.83 TECHNOLOGY FEE $10.97; TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3292 R000.322.900.04.00 0.00 $10.97 $285.10 Date Paid: Monday, October 13, 2014 Paid By: PACIFIC AIR CONTROL INC Pay Method: CHECK 22050 Printed: Monday, October 13, 2014 1:43 PM 1 of 1 SYSTEMS 1,21 I SP CTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 41100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prpject: / A t-Vr Type of Inspe5tion: c ,t,ter ft vvet, ( A dress; 1-5 r Pr Date Called: , Special Instructions: X A-A4 Date Wanted: -,-( 2-- (5- a.m. p.m. Requsster: G°tratoct( tfe.‘1( e'r , Phone No: ) Approved per applicable codes. DCorrections required prior to approval. coMMENTS: A)/ /df AA eltitp 4421- tr -r-€‹5 -r Inspector: D REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 5rdatttroU rit.kry( (A. f Type of Insoection' , /111-944V •FdACt I Address: Date Called: Sp °al Instructions; y Am Date Wuited: a.rn. Request&) rct,, ot tiett.0 Phone No: i 2iDG— ilZ/3- 80031f Approved per applicable codes. Corrections required prior to approval. COMMENTS: r e ctme-,5s- Ccrf F31/- c (....C., Inspector: -Date3 _it _is. REINSPECTION FEE REQUIRED. Prior to next inspedion, tee must be 1---1 paid at 6300 Southcenter Blvd., Suite 100. Can to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ,i mil 144 vv.% A (Gt,/ r % 0 oel ` Type of Inspection: V.di\Ct VI — 1,N„, Address: _ !i-i3 _ ' Date Called:` ". I J Special Instructions: lII � i--r4 �� v 1i Date Wanted: ,�j1 `7 / t (l i f p.„ m m. Requester: Phone No: Approved per applicable codes. jCorrections required prior to approval. COMMENTS: (-1 ) i V l,J l Rc- A 11 — Yeti, ue 1. / `c` o } lAJtL 111bc✓ tL,'hF,v ( (f1 (l- cP n Inspecto�r: 1L�1 Date: /1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be' \jdid at 6300 Southcenter B vd.. Suite 100. Call to schedule reinspection. CIT PER EXISTING GAS PACK UNIT BEING REPLACED WITH NEW, LIKE FOR LIKE • • 698 INDUSTRY DRIVE PERMIT CENTER' 2012 Washin ton State Ener Code Com Iiance Forms for Commercial Grou. R1 and > 3 sto R2 and R3 • Mechanical Summary . MECH-SUM 2012 Washington*Late Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3 Revised June 2013 .7 Project Info PILE COPY No. Project Address / / Z M/L 5 /7 ` ) k i t/ f Date: 10113 j / 4 `Tu K i(li� k v /A1.wI9S/) R LA W J For Building Deept. Use Applicant Name: ]/UVA E, IAC/ VA LT€ RePit Applicant Address:'9i�22,5$SFS1e M I Di Q _ ihk1L Applicant Phone: 2 0b ^ / g� /s- nj �) Wn[ 9,02../ Project Briefly system Description describe mechanical type and features. NIncludes Plans ZtpLc ce -eX'j Sfin9 -)-`orb Roo FTDP GAS PAc f LC n i) I OM A/e/ �GAS p, CK [ j_ -o/V n f Lixe roi Like W/7 7-/ A PPLICA $ Le GLi t3 'bA-Pre, '=CDnompZe{. CNb gAi2orme miC Pe.LieF. Include documentation requiring compliance with commissioning provisions per Section C408. Compliance Option '( imple System Oomplex System Dystems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type pr.( .rc'i Brand Name' t'd Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception6 Heat Recovery Y/N GP-! izru CA RI e rZ tig.TCDAOSA2A3 L47, kmr.ii eor) o /3 41 Heating Equipment Schedule Equip. ID Equip Type PaI Qf Brand Name' CI Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency' Heat Recovery Y/N gP I Mr cAReie 'i TCDAD5A216 5 ,,m0 £cvno `7Z'»BN 5 )8)1 79,. / N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP F. , ., . 5 . , ., . -. - REVEEWED FOR t;OuE CUMPuANCE APPROVED QCI 2 a 2014 Service Water Heating Equipment Schedule . Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category Er Cityttirlileudilea BUILDING DIVISION ocnctucn 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, CombustioCfIrtBIEreFberMW ILA applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception numbe''r``per Simple Systems C403.3.1 or Complex Systems C403.4.1. 7 Efficiency Factor per Table C404.2. MiLk0 4151. OCT 13 2014 PERMIT CENTER Mechanipal Permit Plans Checklist - Page 1 of 3 MECH-CHK R3] Revised June 2013 2012 Washington Statc•Energy Code Compliance/iFormspforfoCommercial, Group R1, and > 3 storry7R22 &&kw," ,,) /� Projec Address t /3 /A/U `/ s / Y' _DR) Ve l H k w / /� 1 .: 188 [Date / 0/13 %/ 9 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHKpages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance /j /j9 C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 YiJ� 1 C403.2.2 Equipment and system sizing heating cooling calculatedOutput loadscapacityof, note exceptionsand takenequipment and systems do not exceed M.-1 �1 ' A v C403.2.5 Minimum ventilation _ Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC t , y e (� (� ' C403.2.3 & C403.2.3.2 & C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment (V kQ C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. /'').!-/� ( yC.s C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) / / % /� / 1r/ C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. `/ [�C Y 1 )/%%— C403.2.3 Maximum air cooled chiller capacitydoes Indicate air-cooled chiller capacity notexceedair-cooledchiller limit NDC403.2.1chillers Non-standard water-cooled Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non- standard operational conditions n 4�(/ C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers 416 I C403.2.3 Forcedheaters air furnace and unit Indicate intermittent ignition or IID, flue/draft damper & jacket loss ,/ % C403.2.3.3 Packaged electric heating/cooling equipment List equipment required to be heat pumps on schedule n %� v C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria AA C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems /� / V C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp iAA-. C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling ��/� C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override / V l C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions f TJ C402.4.5.2 & C403.2.4.4 Dampers p Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions taken) �/�r" 9v MN �1�1 C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls /- C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions n % / ,] C403.2.4.6 Combustionequipment heating Indicate modulating or staged control AI.A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum 1 {� A v C403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken A Af /,� 1 C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV �r I vl ` C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partiallyoccupied �( %t (p� C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method A ,� Tl V t C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method (� ! VV C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or altemative method taken (VAV, semi -conditioned makeup, or GERM calculation) l E5 C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions n , Q1�1 �r C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery P k) 0 C403.2.6.3 Energy recovery - condenser systems Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK 2012 WSShington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3 June 2013 Project Address ')T� / Nr\ Cf TfR Y b k 1 ve T r j 7 , t,// ! L . W/ �) / � �—Rey/vised Date _ _ _ / Lf f ! The following information is necessary to check a mechanical permit application for commercialt�/'provision'complianceWwith the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued AlC403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) , C403.2.12.1 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method ) ✓ ' C J C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken Ayf C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh ' ilA C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and demand response setpoint adiustment Ducting Systems WSC403.2.7.1 & C403.2.7.3 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements / �%%J/ 4/ C403.2.7.3.1-3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans //A, 1%y� `` // C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed ') / ,+'' V,e5 C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork / PipingiSystems Ailet C403.2.8 Piping insulation Indicate R-value of insulation on piping C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems \,(,.$ C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling /// °r/ 111 C403.3 Qualifying 2-pipe heating systems Verify 2-pipe heating -only system does not exceed capacity limits Ai 0 C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 I Simple System Economizers yr t C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. /' /„/ ves C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception / '/ -"- All C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) A, 0 C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh WA' C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) COMPLEX SYSTEMS Complex System Economizers AO C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. NOC403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation /11i� `/ C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems ^ l� Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb /I [) / v •G� C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit - N() C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) Mechanical Permit Plans Checklist - Page 3 of 3 MECH-CHK 2012'Washington ;,!ate Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3 Revised June 2013 '7 Projebt Address /e T 0R I t/, / t1 L�/A Date 3 /jf /) 1 / �2 '7-D Pam' j1 give The following information is necessary to check a mechanical permit appaiLcaattioforlcommercial provisionpr`compliancecoplialwith the 2012 WSEC. NOTE: Define print area In Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements I O C403.4.2 & C403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method AID C403.4.2.1sensors VAV fan static pressure Indicate sensor locations on plans; include at least one sensor per major duct branch AI��% vv C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure /� up C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken AlC403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads / V C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons 1 "/O� /N� C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method { I C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh iti C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use /� '}11/ �/ C403.4.3.6 C403.4.2 & Variable flow control - pumps Indicate pumps requiring variable flow control & method jj I /� L l� C403.2.12.1 & C403.4.4 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method Al C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by ? 50% for systems > 300,000 btuh A / 61rj C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range 1 r l C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes Av f v� C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 R 1 v C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp �' D C403.4.6 Condenser water heat recovery Indicate system provided to pre -heat service water and efficiency y C403.5 Cooler /freezer -anti-sweat heaters Indicate w/sf &control method for walk-in cooler/freezer door anti -sweat heaters C403.5 / 6 Cooler / freezer - evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems /� D 1 j�r C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) A jO C404.3 Temperature controls Indicate temperature controls have required setpoint capability I C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge i�f C404.5 Insulation under water heater Indicate R-10 insulation under tank OC404.6 0 Serviceinsulation water piping Indicate R-value of insulation on piping; note exceptions taken F y� C404.7 / 8 Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas Ki 3C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters z 4 Cop C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or exception taken C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use FILE COPY Permit No. United Technologies SUBMITTAL Project Summit Surgical Date Thursday, October 09, 2014 Contractor Pacific Air Control t1P-I°1qS REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 3 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 1 3 2014 PERMIT CENTER 4t Unit Project: Summit Surgical Prepared By: 10/09/2014 04:09PN 4t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.391 Page 3 of 12 Unit Report For 4t Unit Project: Summit Surgical Prepared By: 10/09/2014 04:09PN Unit Parameters Unit Model. 48TCDA05A2A3-0A0A0 Unit Size. 05 (4 Tons) Volts -Phase -Hertz: 208-1-60 Heating Type- Gas Duct Cfg: Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size- 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity. 2 Return Air Filter Size: 16 x 25 x 2 Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) *** Unit Length- 6' 2.375" Unit Width- 3' 8" Unit Height: 2' 9.375" *** Total Operating Weight: 597 Ib *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 1 48TCDA05A2A3-0A0A0 Rooftop Unit Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 1 Packaged Rooftop Builder 1.391 Page 4 of 12 Project: Summit Surgical Prepared By: Certified Drawing for 4t Unit 10/09/2014 04:09Pt NOTES: 1. 511(NS304PEA N (°L1 181EGs D14EN510N5 2. NWiE CENTER OF GRAVITY 3. y DIRECTION OF AIR FLOW OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET LEFT UNIT 48TC-A04 33 3/8 18471 18 5/8 14121 40TC-A05 33 3E8 1841] 14 7/8 13111 48TC-A06 33 3/8 18413 14 7/8 13111 481E-A01 41 318 110511 14 7/8 13111 44 111111 13.148 I I t 14581 16-1/8 11-3/4 121114 14111 Il6J] 17121 l j 31 1/ 18181 4 SEE THO1XE1 U 8A0E.CHAR1 25 16361 Li 0D7 33 3/8 18481 0 0Nhl00 •0 NoyuA TEGHNULOGIES nuau. • CARRIER I n1 4w1D1n1a X HISS` ie of Fi nlsm uml. ECONOMIZER HOOD 10PIZ0XAL1 25.5/8 165t1 RETURN AIR Ali -- CONDENSATE DRAIN OPENING IN BASEPAN 6-lu I157 FLUE 11000 TOP 11-3/4 14511 SUPPLY 111 12-1/8 13071 18-14t 11101 9 3 OPTIONED0 FACTORY INSTALLED FAC DISCONNECT • CONTROL 801 ACCESS PANEL =_ ,—F IIWJ1]_ fa NI' INDOOR BLOWER ACCESS �NAXDLF NOME 8 3/e 30 Pa12131 11641 ar 130F 2 11-24-08 118881 FRONT 111111111111 09-29-08 Packaged Rooftop Builder 1.391 164061 01R/8 1.1 RETURN AIR -318 1110 411 SUPPE/ R 3-3/8 1851 CONNECTION SIZES 1 3/8' 135] DIA FIELD POWER SUPPLY HOLE 2' 1501 DIA POWER SUPPLY ANOCx0U1 1 3/4. 151] DIA GAUGE ACCESS PLUG 1/8. PPE DIA f1ELD CONTROL WIRING XOLE 3/4'-14 NPT CONDENSATE DRAIN 1/2..14 8PT 6AS CONNECTION 2 1/2 ' 1641 DIA PRYER SUPPLY KNOCK -OUT IORU'TNE-BA E CNAP THESE HOLES REQUIRED FOR USE CRBT4PWA001A01, 003A01 1PREADED 0IRE REO-D NOTE CONDUIT SIZE USE SIZES IAAY.1 I/O' ACC. 1/8' 122 21 A 1/2' 11,1 1/8' Itt.il • 3/1' 1001,0031 POWER 1 I/O' 128.41 t•• 10031 I/O' 1P1 GAS 1 3/16' 130.01 1Oe '1NRD-TNE-BASE AN' EA i0RY OPTION, I00118G3 008 ONLY ,Y, 6 Z ARE PROVIDED • SELECT EITHER 3/4. 0R 1/7' fOR POWER, DEPENDING ON WIRE 517E •• 10011 PROVIDES 3/4' F11 1H0U CURB FLANGE 6 FITTING 48TC 04-01 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT BAROMETRIC RELIEF FOIE 48TM500993 5.0 Page 5 of 12 Certified Drawing for 4t Unit Project: Summit Surgical Prepared. By: 10/09/2014 04:09PWV UNI1 S7D UNIT WEIGHT CORNER WE16111 117 CORNER NE]DN1 IBI CORNER WEILNT ICI CORNER WEIGHT ID/ C G. 011GNI LBS. CO. LBS. AG, IBS. NO. LBS. NG. LBS. 80, I 7 7 61510-104 183 219 111 50 125 51 731 59 116 53 39 (911] 23 [5811 16 3/0 11161 4670.105 531 211 124 56 139 63 115 66 129 59 39 19917 23 15841 1) 11321 6810.606 561 258 131 59 111 61 151 10 137 62 39 19917 23 15811 11 116 14381 681C.101 652 296 ISO 68 169 16 176 80 157 11 39 1991) 23 1501] 20 I/B 15111 CORNER A CORNER D TOP jiijI 6:1�wOo UNITED061[S a11u0. <Ns[01 98 CARRIDpIRV . o,R IONWEASIEFL CORNER 8 CORNER C FRONT oor 1 6nm 2 Of2 01,1 11-24-08 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48114500993 570 Packaged Rooftop Builder 1.391 Page 6 of 12 Certified Drawing for 4t Unit Project: Summit Surgical 10/09/2014 Prepared By: 04:09PN Service Clearance I C0R3) LOCATION DIMENSION CONDITION A 48-in (1219 min) • Unit disconnect is mounted on panel 3134n (457 min) • No disconnect, convenience outlet option • Recommended 5mi. dears nce 12-In (305 min) • Minimum clearance R 42-n (1067 min) •Srface behind serviceris grounded (e.g., metal, masonry wall) 36. n (914 min) •Srface behind servicer h electrkaIly non-conductive (e.g., wood, fiberglass) Special •Check for sources offlue products eaten 10- ft. of unit freshalr Intake hood C 36an (914 min) • Sde condensate drain Isused 18-in (457 min) • Minimum clearance D 46-In (1219 mm) • No flue discharge actessorylmtalled, surfaceIs combustible material 42-in (1067 min) • Surface behind seMcerIs grounded (e.g., metal, masonry wall, another unit) 364n (914 min) • Surface behind servicerh electrkelly nonrnMuctNe (e.g.,wood, fiberglass) Special • Check for adjacent units or building fresh air Intakes wltNn 10- ft. of this uNt's flue outlet NOTE: Unit not designed to have overhead obstruction. ComactApplication Engineering for guidance on any application planning overhead obstruction or vertical clearances. Packaged Rooftop Builder 1.391 Page 7 of 12 OPTIONS: MATERIAL: 18ga. GAL STEEL INSULATED PANELS (WHERE REQUIRED) 1" 1-1/2LB DUCT INSULATION (R VALUE 3.85) GASKET PROVIDED WITH CURB 1 1/2" ADDED TO EXISTING CURB O.D. 115 3/4" 22 1/8' 1F.6,- 40 9/16' �— 38 3/4' —� INIMISIOMED APPS POSERERCED PEP ANSI PIP SWIMS Attn: Tag: Approval: EXISTING CURB CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. No.�NEv. REVISIONS DESCRIPTION DATE APPRV 18 5/8' 70 7/8' 12. 97/16' 74 1/2' CURB KvcxTNU APPROVALS DATE A. LUTTINEN 721/06 'VERIFY EXISTING LURE OD VERIFY SUPPLY AND RETURN OPENINGS NOTE ANY GRANGES 'CALL WITH ANY QUESTIONS 'FAX BACK IF DRAWING IS OK AS 15 17560 TYLER 5T NW CDIELK RIVER, MN (7763)391.7790 55330 tux.. 1-5005-4000 1-5005-4000 1-5005-4000 O2 wu, 1,25 I een. 2 or 2 Performance Summary For 4t Unit Project: Summit Surgical Prepared By: 10/09/2014 04:09PN Part Number:48TCDA05A2A3-0A0AO ARI SEER• 13.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width: 44.0 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 537 Ib Medium Static Option. 10 Ib Accessories Standard Leak Vertical EconoMi$er IV with solid-state controller: 50 Ib Total Operating Weight: } 597 Ib Unit wG Unit Voltage -Phase -Hertz: 208-1-60 Air Discharge- Vertical Fan Drive Type. Belt Actual Airflow: 1600 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/Ib Evaporator Leaving Air DB• 60.2 F Evaporator Leaving Air WB: 57.7 F Evaporator Leaving Air Enthalpy 24.83 BTU/Ib Gross Cooling Capacity: 47.60 MBH Gross Sensible Capacity 34.22 MBH Compressor Power Input: 3.31 kW Coil Bypass Factor: 0.246 Heating Performance Heating Airflow: 1600 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 102.4 F Gas Input Capacity 72.0 MBH Gas Heating Capacity: 56.00 MBH Temperature Rise: 32.4 F Supply Fan External Static Pressure. 0.75 in wg Options / Accessories Static Pressure Economizer 0.07 in wg Total External Static: 0.82 in wg Fan RPM: 1079 Fan Power. 0.95 BHP NOTE: Selected IFM RPM Range: 770 - 1175 Electrical Data Voltage Range: 187 - 253 Compressor #1 RLA• 21.8 Compressor #1 LRA• 117 Indoor Fan Motor Type- MED Indoor Fan Motor FLA: 4.9 Combustion Fan Motor FLA (ea). 0.48 Packaged Rooftop Builder 1.391 Page 8 of 12 Performance Summary For 4t Unit Project: Summit Surgical Prepared By: 10/09/2014 04:09PN Power Supply MCA: 34 Power Supply MOCP (Fuse or HACR)- 50 Min. Unit Disconnect FLA- 32 Min. Unit Disconnect LRA: 133 Electrical Convenience Outlet: None Outdoor Fan [Qty / FLA (ea)]: Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 87.1 87.3 90.9 125 Hz 81.4 78.5 84.6 250 Hz 73.2 64.9 79.5 500 Hz 69.1 62.9 77.9 1000 Hz 65.7 62.1 76.5 2000 Hz 60.1 56.1 71.1 4000 Hz 61.7 51.6 66.9 8000 Hz 56.9 44.2 62.5 A -Weighted 72.7 68.3 81.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7 68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C 58.5 52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 Lp D 32.3 36.1 38.5 42.3 44.1 39.9 35.5 29.0 48.4 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw 1 / 1.5 Packaged Rooftop Builder 1.391 Page 9 of 12 Project: Summit Surgical Prepared By: Performance Summary For 4t Unit 10/09/2014 04:09PN B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 2.0 1.8 1.6 1.4 0.6 0.4 0.2 0.0 900 RPM - 700 RPM 00 500 RPM Fan Curve 100 RPM 3M 0.3 06 09 1.2 1 5 Airflow (CFM - thousands) RPM = 1079 BHP = 0.95 Maximum RPM = 1175 Maximum BHP = 2.40 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point PM 18 21 3 0 BHP 2.00 B 50 BHW 24 Packaged Rooftop Builder 1.391 Page 10 of 12 Unit Feature Sheet for 4t Unit Project: Summit Surgical Prepared By: 10/09/201 4 04:09PN WeatherMaker` — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5,10,12.5,15 TONS Optional Louvered Hail Guard ShoRn J4 ui. n- WEATHERMAKER SERIES WeatherMaker (48TC) units are one-piece gas heating; electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factory tested in both heating and cooling modes, and rated in accordance with AHRI Standards 210/240(04-06 sizes) and 340/360 (07-16 sizes). WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approvedand certified by: US Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Puron (R-410A) HFC refrigerant • ASHRAE90.1 energy compliant • Scrollcompressorswith internal brie break and overload protection • Single stage cooling capacity control on 04-12 models • Two --stage poling capacity control on 08-16 models • SEER'aupto 13.0,EER'supto11.1 and 1EER'aupto11.8 • Acutror• refrigerant metering system • Exclusive non-carrosive composite condensate pan in accordance with ASHRAE Standard 62. sloping design, side or center drain • Standard cooling operation up to 1 15'F (46'C)and down to 40'F - down to 25' F (-4' C) with winter start kit. • Pre -painted exteriorpanels and prirnercoated interior panels tested to 500 hours salt spray protection • Fully insulated cabinet • Exclusive IGC solid-state control for on -board diagnostics with LED error code designation bumercontrol logic and energy saving indoor fan motor delay • Low Wax models that meet California Air Quality Management • Induced draft gas heat combustion design • Redundant gas valves with tip to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: • Acoess panels 'Nth easy grip handles • Innovative easy starting, no -strip screws on unit access panels • Two-inch disposable return air fitters and Tool -less filter access door • Sett drive evaporator -fan motor end pulley combinations • Hew terminal board facilitating simple safety circuit troubleshooting end simplified control box arrangement • Exclusive !GC solid-state control for on -board diagnostics with LED enor code designation. burner control logic and energysaving indoor fan motor detsy. INSTALLATION FEATURES: • Thru-the-bottom power entry cepsbrlity • Single point gss endelecuic connections • Fullperimeter base rat with but -in rigging adapters and fork slots • Field convertibtofrom vertical to horirontsl airflow for stsb mounting. (16 size models require field instssed supplyductoover). STANDARD WARRANTY: • 10-year heat exchanger— 15-yearstainless steel option • 5-year compressor • 1-yesrpsrts • 3-yeerparts on Novation Condensercoits —where available • Msnyoptionatupgrsdesalso avalsbt_ OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • PremierLink"r and RTU Open Multi Protocol DDC Controls • Supply and Return Air Smoke Detector, high ststic motor • Louvered condenserooiiguerds • Economizer, disconnect and convenianoe outlet options • Stainless Steel heat exchanger option • Corrosion resistant cot coating. • Humid± -Miter= adaptive dehumidification system available on es models with RTPF condensercois — Motor Msster I controller included • Hinged access panels For a complete lost of options and accessories refer to the Product Date Catalog for this unit. Packaged Rooftop Builder 1.391 Page 11 of 12 Spec Sheet for 4t Unit Project: Summit Surgical Prepared By: 10/09/2014 04:09PN Packaged Rooftop Builder 1.391 Page 12 of 12 FILE COPY XI SINGLE PACKAGE AIR-COOLED CONVERTIBLE SERIES AIR CONDITIONERS DDHB 036 048 060 & DBHB 072 DHUC 036, 060 & DBUC 072 3, 44AND 5 48;NAL TONS (10 SEER) 6 WOMINAL TONS (9 EER) REVIEWS CODE COMPLIANCE APPROVED OCT 2 3 2014 City of Tukwila BUILDIN RECEIVED CITY OF TUKWILA OCT 13 2014 PERMIT CENTER MODEL DHB MODEL DUC 11-1%. 0 igt� 530.18-TG 1 L (397) DESCRIPTION The DHB and DUC units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for residential, light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self-contained and assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide for a quick and easy field installation. The units are available in cooling only, and cooling with gas heat. Electric heaters are available as field -installed accessories. The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 750 hour salt spray tests per ASTM-B117 standards. All models include a 5-year limited warranty on scroll compressors and electric heating elements, a 10-year limited warranty on gas -fired heat exchangers and a 1-year limited warranty on all replacement parts. FEATURES COMMON FOOTPRINT/COMMON CABINET - All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal Toad has been determined. He can even decide between gas or electric heat after the curb has been set.h HIGH EFFICIENCY - All units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 80%. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom return is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. Economizers may be used on either bottom and side duct applications with no modifications required. FACTORY -INSTALLED OPTION - Adjustable belt -drive blower is available on all models from the factory to provide maximum air flow flexibility. FIELD -INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the internal partitions to connect the elements to the control box single point kit. Cont'd. 530.18-TG1 FEATURES - CONT'D. The 14" high roof curb is shipped knocked down. An insulated deck is not required because the bottom of the unit is insulated. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0°F. Propane, high altitude and low NOx kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5-ton models operate over a wide range of design conditions with a 3-speed direct -drive fan motor. The 6-ton unit has a single speed direct -drive fan motor. Belt -drive blowers are also available on all models. FULL PERIMETER BASE RAILS - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. SYSTEM PROTECTION - Internal overload protection are standard on all scroll compressors. Every unit has a liquid line filter -drier, high and low pressure/loss at charge switches and a suction line freezestat to protect all system components. All units will provide cooling at ambient temperatures down to 45°F. UTILITY CONNECTIONS MADE EASY - Gas and electric utility knockouts are provided in the unit base as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit board contains a scroll compressor lockout indicator light and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Mate-n-lock plug connectors are used where line and low voltage wires pass thru internal bulkheads. This allows for easier troubleshooting and component replacement. The electrical control box is not located in the scroll compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. AIR FILTERS - Units are shipped with 1" disposable filters. The unit filter racks can accommodate 1" or 2" filters without any modifications. HIGH -EFFICIENCY CONVERTIBLE ROOFTOP LOW VOLTAGE RELAY BOARD 20 GAUGE ALUMINIZED STEEL AND TERMINAL STRIP TUBULAR HEAT EXCHANGER ELECTRICAL DISCONNECT MOUNTING LOCATION (Field Installed) ECONOMIZER HOOD OUTDOOR AIR OPENING FOR SLIDE-IN/PLUG IN INTERNAL ECONOMIZER (ACCESSORY) SIDE RETURN AIR DUCT OPENING (Return Air & Supply Air Side by Side) BOTTOM RETURN AIR DUCT OPENING (Retum Air & Supply Air Side by Side) 3/4" PVC FEMALE CONDENSATE DRAIN KNOCKOUTS FOR SIDE POWER AND CONTROL ENTRY DIRECT -DRIVE BLOWER MOTOR (Belt -Drive Option also available on some models) TERMINAL BLOCK (For Single Point Power Supply on Elec/Elec Units) ELECTRIC HEAT ACCESSORY LOCATION (Elec/Elec Units) POWER VENTER MOTOR KNOCKOUT FOR BOTTOM GAS SUPPLY ENTRY KNOCKOUT FOR BOTTOM POWER ENTRY COPPER TUBE/ ALUMINUM FIN CONDENSER COIL HIGH EFFICIENCY SCROLL COMPRESSORS BASE RAILS WITH FORKLIFT SLOTS AND LIFTING HOLES KNOCKOUT FOR SIDE GAS SUPPLY ENTRY TABLE OF CONTENTS Description 1 Features 1 & 2 Ratings 3 Physical Data 3 Component Weights 3 Cooling Capacities - 3 Ton 4 Cooling Capacities - 4 Ton 5 Cooling Capacities - 5 Ton 6 Cooling Capacities - 6 Ton 7 Blower Performance - 3 & 4 Ton w/Belt-Drive 8 Blower Performance - 5 & 6 Ton w/Belt-Drive 9 Blower Performance - 3 - 6 Ton w/Direct-Drive 10 Option and Accessories 10 MODEL DUC (Gas Heating) Static Resistances 11 Motor and Drive Data 11 Electrical Data - Basic Units w/Direct-Drive 11 Electrical Data - Basic Units w/Belt-Drive 11 Elec. Data-CIg./Elec. Htg. 3 & 4 w/Direct-Drive 12 Elec. Data-Clg./Elec. Htg. 5 & 6 w/Direct-Drive 13 Elec. Data-Clg./Elec. Htg. 3 & 4 w/Belt-Drive 14 Elec. Data-Clg./Elec. Htg. 5 & 6 w/Belt-Drive 15 Field Wiring 16 Unit Dimensions 17 & 18 Roof Curb Dimensions 19 Typical Applications 20 Guide Specifications 21 2 Unitary Products Group 530.18-TG1 RATINGS CAPACITY RATINGS - Cooling/ Electric Heatin MODEL ARI RATINGS' NOMINAL ELECTRIC HEAT CAPACITY3 (KW) STANDARD CFM COOLING CAPACITY 80 / 67-95°F SOUND RATING2 (dbels) MBH SEER EER 240V 480V 600V DHB036 36.0 10.00 9.10 82 5 7, 10, 15&20 7, 10, 15&20 10, 15&20 1.300 DHB048 47.4 10.00 9.00 82 5 7, 10, 15&20 7, 10, 15&20 10, 15&20 1.700 DHB060 59.0 10.00 ,9.10 82 5, 7, 10, 15, 20 & 30 7, 10, 15 20.& 30 10, 15, 20 & 30 2.100 DHB072 72.0 - 9.00 84 5, 7, 10, 15 20 & 30 7, 10, 15, 20 & 30 10, 15, 20 & 30 2.400 CAPACITY RATINGS - Cooling / Gas Heatin MODEL ARI RATINGS1 GAS HEAT CAPACITY STANDARD CFM COOL NG CAPACITY 80 / 67-95°F SOUND RATING2 (dbels) INPUT OUTPUT (MBH) AFUE (%) S.S.E. (/o) TEMP. RISE (°F) GAS LINE SIZE (in. OD) MBH SEER EER DUC036N040 DUC036N079 36.0 36.0 10.00 10.00 9.10 9.10 82 82 50 100 40 79 80.9 80.5 81.6 80.8 15-45 40-70 1/2 1/2 1.300 DUC048N060 DUC048N099 47.4 47.4 10.00 10.00 9.00 9.00 82 82 75 125 59 99 80.9 80.3 81.6 80.6 25-55 45-75 1/2 1/2 1.700 DUC060N079 DUC060N099 59.0 59.0 10.00 10.00 9.10 9.10 82 82 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 1/2 1/2 2.100 DUC072N079 DUC072N099 72.0 72.0 - - _ 9.00 9.00 84 84 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 1/2 1/2 2.400 Ratings are in accordance with ARI Standard 210. 2Sound ratings are in accordance with ARI Standard 270. 3Heaters are available as accessories - all with single point power supply. SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. EER = Energy Efficiency Ratio - the cooling capacity in Btu's per hour (Btuh) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure. S.S.E. = Steady State Efficiency. (Percent Output). Not ARI Listed. PHYSICAL DATA - BASIC UNITS COMPONENT WEIGHTS MODELS DHB/DUC EVAPORATOR BLOWER EVAPORATOR COIL COMPRESSOR TYPE CENTRIFUGAL (Dia. x Wd. in.) 036 12 x 10 048 12 x 10 060 12 x 10 072 12 x 11 FAN MOTOR HP (DIRECT -DRIVE) FAN MOTOR HP (BELT -DRIVE) ROWS DEEP 1/2 1 1/2 3 3/4 11/2 3 1 11/2 3 1 11/2 4 FINS PER INCH 13 13 13 13 FACE AREA (Sq. Ft.) HERMETICALLY SEALED 3.6 4.3 5.1 BRISTOL SCROLL 5.1 CONDENSER FAN CONDENSER COIL AIR FILTERS (SEE NOTE) CHARGE PROPELLER DIA. (in.) FAN MOTOR HP 24 1/4 24 1/4 24 24 1/4 1/4 NOM. CFM TOTAL ROWS DEEP FINS PER INCH 3,400 1 16 3,400 1 16 3,400 1 22 3 300 2 16 FACE AREA (Sq. Ft.) QUANTITY PER UNIT (15"X20"X1") QUANTITY PER UNIT (14"X25"X1") TOTAL FACE AREA (sq. ft.) 17.1 2 1 6.3 REFRIGERANT I 5/8 R-22 (Ibs./oz.) 17.1 2 1 6.3 6/8 17.1 16.7 2 2 6.3 6.3 6/8 10/0 Basic Unit COMPONENT DHB Coolin. on DUC (Gas /Electric) 79 Mbh 99 Mbh DHB 048 565 036 515 585 & DU 0.0 90 650 072 670 725 635 660 735 Options and Accessories Economizer 50 Motorized Outdoor Air Damper Electric Heat (Nominal KW) (DHB only) 5 7 KW 48 18 10- 15 KW 23 20 - 30 KW 28 Roof Mounting Curb Relief / Fixed Air Damper Belt -Drive Blower NOTE: Weights are given in pounds. • +a,L uJ I,tm4`1- G 727 L4 92 10 NOTE: Filter racks are adapted for 1" or 2" thick filters. Unitary Products Group 3 530.18-TG1 COOLING CAPACITIES - 3 TON (DHB / DUC036) Air On Evaporator Coil Temperature of Air on Condenser Coil Total Power Input2 85°F Sensible Capacity, MBH l Total Power Input2 ,k •,e Sensible Capacity/, MBH CFM WB Cap./ Entering Dry Bulb, °F Cap./ Enterinq Dry Bulb, °F 86 83 80 77 74 71 68 86 83 POI 77 74 71 68 °F MBH KW MBH KW 72 45 3.1 35 30 26 21 17 - - 43 3.3 35 30 26 21 17 - - 1750 67 43 3.0 43 38 34 29 25 20 16 41 3.3 41 38 34 29 25 21 16 62 39 3.0 39 39 39 34 30 25 21 36 3.3 36 36 36 32 27 23 18 57 40 2.9 40 40 40 35 31 26 22 38 3.2 38 38 38 33 29 24 20 72 44 3.1 31 28 24 20 16 - - 42 3.3 31 27 23 20 16 - - 1475 67 41 3.0 39 35 31 27 23 19 16 39 3.3 37 35 31 27 23 19 15 62 38 3.0 38 38 37 33 29 25 21 36 3.3 36 36 35 31 27 23 19 57 39 2.9 39 39 39 35 31 27 23 37 3.2 37 37 36 32 28 25 21 72 42 3.1 28 25 22 18 15 - - 41 3.3 28 24 21 18 14 - - Ea!) 62 40 36 3.0 3.0 35 36 32 36 28 35 25 31 22 28 18 25 15 21 3.3 34 35 31 35 ell 34 25 30 21 27 18 24 15 20 35 57 37 2.9 37 37 37 34 31 27 24 36 3.2 36 36 35 32 28 25 22 72 41 3.1 26 23 20 17 14 - - 39 3.2 26 23 20 17 14 - - 1050 67 38 3.0 32 30 27 24 21 18 15 37 3.2 32 29 26 23 20 17 14 62 35 3.0 35 35 33 30 27 24 21 33 3.2 33 33 31 28 25 22 20 57 36 2.9 36 36 35 32 29 26 23 34 3.2 34 34 32 30 27 24 21 72 39 3.1 24 21 19 16 14 - - i 38 3.2 23 21 18 16 13 - - 900 67 37 3.0 30 27 25 22 20 17 15 36 3.2 29 26 24 21 19 16 14 62 34 3.0 34 33 30 28 25 23 20 32 3.2 32 31 29 26 24 21 19 57 34 2.9 34 34 33 30 27 25 22 33 3.1 33 33 30 27 25 22 20 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Cap./ Power Input2 Sensible Capacity/, MBH Total Cap./ Power Input2 Sensible Capacity/ MBH CFM WB Enterin D Bulb °F Enterin D Bulb °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F MBH KW MBH KW 72 41 3.7 34 29 25 20 16 - - 39 4.1 33 28 24 19 15 - - 1750 67 38 3.7 38 37 33 28 24 19 15 36 4.0 36 36 32 27 23 18 14 62 34 3.7 34 34 34 30 25 21 16 32 4.0 32 32 32 27 23 18 14 57 35 3.6 35 35 35 31 26 22 17 33 4.0 33 33 33 28 24 19 15 72 40 3.7 30 26 23 19 15 - - 38 4.1 30 26 22 18 14 - - 1475 67 37 3.6 36 34 30 26 22 18 14 35 4.0 34 33 29 25 21 17 13 62 33 3.7 33 33 33 29 25 21 17 31 4.0 31 31 31 27 23 19 15 57 34 3.6 34 34 34 30 26 22 18 32 4.0 32 32 32 28 24 20 16 72 39 3.7 27 24 20 17 14 - - 37 4.1 26 23 20 16 13 - - 1200 67 36 3.6 34 30 27 24 20 17 14 34 4.0 33 30 26 23 20 16 13 62 32 3.6 32 32 32 29 25 22 19 30 4.0 30 30 30 27 24 20 17 57 33 3.6 33 33 33 29 26 23 19 31 3.9 31 31 31 27 24 21 17 72 37 3.6 25 22 19 16 13 - - 36 4.1 24 21 18 15 12 - - 1050 67 35 3.6 31 28 25 22 19 16 13 32 4.0 30 27 24 21 18 15 12 62 31 3.6 31 31 29 27 24 21 18 29 4.0 29 29 28 25 22 19 16 57 32 3.5 32 32 30 27 24 21 18 30 3.9 30 29 28 25 22 19 16 72 36 3.6 22 20 17 15 12 - - 34 4.0 21 19 16 14 11 - - 900 67 33 3.6 28 25 23 20 18 15 13 31 4.0 27 24 22 19 17 14 11 62 30 3.6 30 29 27 24 22 19 17 28 4.0 28 28 25 22 20 17 15 57 31 3.5 31 30 28 25 22 20 17 28 3.9 28 28 25 23 20 17 15 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. 11115 NOMINAL RATING ALL SENSIBLE CAPACITY 4 Unitary Products Group 530.18-TG1 COOLING CAPACITIES - 4 TON (DHB / DUC048) Air On Evapo ator Coil Temperature of Air on Condenser Coil Total Cap.1 Power Input2 85°F Sensible Capacityl, MBH Total Power Input2 ..� Sensible Capacityl, MBH CFM WB Entering Dry Bulb, °F Cap.1 Entering Dry Bulb, °F 86 83 80 77 74 71 68 MBH 86 77 74 71 68 °F MBH KW KW 72 60 4.1 44 39 33 28 23 - - 60 4.5 44 _DAM 39 33 28 23 - - 2000 67 55 4.1 53 48 42 37 32 26 21 52 4.5 52 47 42 36 31 25 20 62 51 4.0 51 51 51 45 40 34 29 48 4.4 48 48 48 42 37 32 26 57 49 3.9 49 49 49 44 39 33 28 47 4.3 47 47 47 42 36 31 26 72 58 4.1 41 36 31 26 21 - - 57 4.5 41 36 31 26 21 - - 1800 67 53 4.1 49 45 40 35 30 25 20 50 4.5 49 44 39 34 29 24 19 62 49 4.0 49 49 48 43 38 33 28 46 4.4 46 46 46 41 36 31 26 57 47 3.9 47 47 47 43 38 33 28 45 4.3 45 45 45 40 36 31 26 72 56 4.1 38 34 29 25 20 - - 55 4.6 38 33 29 24 20 - - F r CI 51 4.1 46 41 37 32 28 24 19 9 WI 45 40 Ira 31 27 23 18 62 47 4.0 47 47 45 41 36 32 27 44 4.4 44 44 44 40 35 31 26 57 46 3.9 46 46 46 41 37 32 28 44 4.4 44 44 44 39 35 30 26 72 54 4.1 35 31 27 23 19 - - 53 4.5 35 31 27 23 19 - - 1400 67 49 4.1 42 38 34 30 26 22 19 47 4.5 41 38 34 30 26 22 18 62 45 4.0 45 45 42 38 34 30 26 43 4.4 43 43 41 37 33 29 25 57 44 3.9 44 44 43 39 35 31 27 42 4.3 42 42 41 37 33 29 25 72 52 4.1 32 29 25 22 18 - - 51 4.5 32 28 25 21 18 - - 1200 67 47 4.1 39 35 32 28 25 21 18 45 4.4 38 35 31 28 24 21 17 62 43 4.0 43 43 39 36 32 29 25 41 4.3 41 41 38 35 31 28 24 57 42 3.9 42 42 39 36 32 29 25 41 4.3 _ 41 41 38 34 31 27 24 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Cap.1 MBH Power Input2 KW Sensible Capacityl, MBH Total Cap.1 MBH Power Input2 KW Sensible Capacityl, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 2000 72 67 62 57 56 49 45 44 5.1 5.0 4.9 4.9 42 49 45 44 37 46 45 44 31 40 45 44 26 35 39 39 21 29 34 33 - 24 28 28 - 19 23 22 53 46 41 41 5.6 5.5 5.4 5.4 40 46 41 41 35 44 41 41 29 39 41 41 24 33 36 35 19 28 30 30 - 23 25 25 - 17 20 19 1800 72 67 62 57 55 48 43 43 5.0 5.0 4.9 4.9 39 47 43 43 34 43 43 43 29 38 43 43 24 33 38 38 20 28 33 33 - 23 28 28 - 18 23 23 52 45 40 40 5.5 5.4 5.4 5.4 38 45 40 40 33 42 40 40 28 37 40 40 23 32 35 35 18 27 30 30 - 22 26 25 - 17 21 20 1600 72 67 62 57 53 46 42 41 5.0 4.9 4.9 4.8 36 44 42 41 32 40 42 41 28 35 42 41 23 31 37 37 19 26 33 32 - 22 28 28 - 17 24 23 51 44 39 39 5.5 5.4 5.3 5.3 35 44 39 39 31 39 39 39 26 35 39 39 22 30 35 34 17 26 30 30 - 21 26 25 - 17 21 21 1400 72 67 62 57 51 44 40 40 5.0 4.9 4.8 4.8 33 41 40 40 29 37 40 40 26 33 39 38 22 29 35 34 18 25 31 30 - 21 27 26 - 17 23 22 48 42 37 37 5.5 5.3 5.3 5.3 32 40 37 37 28 36 37 37 24 32 36 36 20 28 32 32 16 24 28 28 - 20 24 24 - 16 20 20 1200 72 67 62 57 49 42 38 38 4.9 4.9 4.8 4.8 30 37 38 38 27 34 38 38 23 30 36 35 20 27 32 32 16 23 29 28 - 20 25 25 - 16 22 21 46 39 35 35 5.4 5.3 5.3 5.3 29 36 35 35 26 33 35 35 22 29 33 33 19 26 29 29 15 22 26 26 - 19 22 22 - 15 19 19 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. Mr NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 5 530.18-TG1 COOLING CAPACITIES - 5 TON (DHB / DUC060 Air On Evaporator Coil Temperature of Air on Condenser Coil 85°F ff `' era Total Power Input` Sensible Capacityl, MBH Total Power Input2 Sensible Capacityl, MBH CFM WB Cap.1 Entering Dr Bulb °F Cap.1 Enterin. Dr Bulb °F 86 83 80 77 74 71 68 MBH 86 83 77 74 71 68_ °F MBH KW KW 72 68 4.9 50 44 38 32 25 - - 65 5.6 50 43 37 31 24 - - 2500 67 62 4.8 62 56 50 43 37 31 24 60 5.3 60 54 48 42 35 29 23 62 57 4.7 57 57 57 51 44 38 32 53 5.3 53 53 53 47 41 34 28 57 55 4.7 55 55 55 48 42 36 29 51 5.4 51 51 51 44 38 32 25 72 67 4.9 48 42 36 30 24 - - 65 5.4 47 41 35 29 23 - - 2250 67 62 4.8 59 53 47 41 35 30 24 59 5.2 57 51 45 40 34 28 22 62 56 4.7 56 56 56 50 45 39 33 53 5.2 53 53 53 47 41 35 29 57 54 4.7 54 54 54 48 42 36 31 50 5.3 50 50 50 44 39 33 27 72 66 4.9 45 39 34 29 23 - - 64 5.3 44 39 33 28 22 - - 61 4.8 55 50 44 39 34 28 23 58 5.1 54 48 4 38 32 27 22 62 55 4.7 55 55 55 50 45 39 34 52 5.1 52 52 52 47 42 36 31 57 53 4.6 53 53 53 48 42 37 32 50 5.2 50 50 50 44 39 34 28 72 63 4.8 41 36 31 27 22 - - 61 5.4 40 35 31 26 21 - - 1750 67 58 4.7 51 46 41 36 32 27 22 56 5.1 49 44 39 35 30 25 21 62 53 4.6 53 53 51 47 42 37 32 50 5.2 50 50 48 43 39 34 29 57 51 4.6 51 51 49 44 40 35 30 47 5.2 47 47 46 41 36 32 27 72 60 4.8 37 33 29 25 21 - - 58 5.4 36 32 28 24 20 - - 1500 67 56 4.7 46 42 38 34 30 26 21 53 5.2 44 40 36 32 28 24 20 62 51 4.6 51 51 47 43 39 35 31 47 5.2 47 47 44 40 36 32 27 57 49 4.6 49 49 45 41 37 33 29 45 5.3 45 45 42 38 34 29 2 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Power Input` Sensible Capacityl, MBH Total Power Input2 Sensible Capacityl, MBH CFM WB Cap.1 Enterin Dry Bulb, °F Cap.1 Enterin Dry Bulb, °F 86 83 ,_ 80 J 77 74 71 68 86 83 80 [ 77 74 71 68 °F MBH KW MBH KW 72 61 6.1 48 41 35 29 22 - - . 57 6.7 46 39 33 27 20 - - 2500 67 55 5.9 55 52 46 39 33 27 20 50 6.6 50 50 43 37 31 24 18 62 49 5.9 49 49 49 42 36 30 23 44 6.5 44 44 44 38 31 25 19 57 47 5.9 47 _ 47 47 40 34 28 21 42 6.5 42 42 42 36 30 23 17 72 61 6.0 45 39 33 28 22 - - 57 6.6 43 38 32 26 20 - - 2250 67 54 5.9 53 49 44 38 32 26 20 50 6.5 50 47 42 36 30 24 18 62 48 5.8 48 48 48 42 37 31 25 44 6.4 44 44 44 38 32 26 20 57 46 5.8 46 46 46 40 35 29 23 42 6.4 42 42 42 36 31 25 19 72 60 6.0 42 37 32 26 21 - - 57 6.6 41 36 _ 30 25 20 - - 2000 67 54 5.8 52 47 41 36 31 25 20 50 6.5 50 45 40 34 29 24 18 62 48 5.7 48 48 48 43 37 32 27 44 6.4 44 44 44 38 33 28 22 57 46 5.8 46 46 46 41 35 30 25 42 6.3 42 42 42 37 32 26 21 72 57 6.0 38 34 29 24 19 - - 53 6.5 37 32 27 23 18 - - 1750 67 51 5.8 47 42 38 33 28 24 19 46 6.4 45 41 36 31 26 22 17 62 45 5.7 45 45 44 39 34 30 25 41 6.3 41 41 39 35 30 25 21 57 43 5.8 43 43 42 37 32 28 23 39 6.3 39 _ 39 38 33 29 24 19 72 54 6.0 34 30 26 22 18 - - 49 6.5 33 28 24 20 16 - - 1500 67 48 5.8 42 38 34 30 26 22 18 43 6.4 40 36 32 28 24 20 16 62 43 5.7 43 43 39 35 31 27 23 38 6.3 38 38 35 31 27 23 19 57 41 5.8 41 41 38 34 30 26 21 37 _ 6.2 37 37 34 30 26 22 18 1 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY 6 Unitary Products Group 530.18-TG1 COOLING CAPACITIES - 6 TON (DHB / DUC072 Air On Evaporator Coil Temperature of Air on Condenser Coif 85°F ` � „v, i �r.. Total Power Input2 Sensible Capacityl, MBH Total Power Input2 Sensible Capacityl, MBH CFM WB Cap.1 Entering Dry Bulb, °F Cap.1 Entering Dry Bulb, °F 86 , 83 80 77 74 71 68 MBH 86 83 ; a 77 74 71 68 °F MBH KW KW 72 80 5.7 63 55 1 47 40 32 - - 77 6.3 63 55 47 40 32 - - 2700 67 80 5.7 76 68 60 53 45 37 30 77 6.3 75 68 60 53 45 37 30 62 70 5.5 70 70 70 62 55 47 39 71 6.3 71 71 71 63 56 48 40 57 68 5.6 68 68 68 60 52 45 37 71 6.3 71 71 71 63 56 48 40 72 82 5.7 60 53 46 38 31 - - 76 6.3 60 53 46 39 31 - - 2550 67 82 5.7 73 65 58 51 43 36 29 76 6.3 73 66 58 51 44 36 29 62 71 5.5 71 71 70 62 55 48 41 70 6.3 70 70 69 62 55 48 40 57 69 5.6 69 69 69 62 55 47 _ 40 70 6.3 70 70 70 62 55 48 40 a 72 1 T 83 5.7 58 51 44 37 30 - - 75 _ 6.3 58 51 44 37 30 - - 16", '.' 83 5.7 70 63 56 49 42 35 28 Y1; y ..a , 70 64 `0 , : 50 43 36 29 •' 62 73 5.5 73 73 70 63 56 49 42 69 6.3 69 69 68 61 54 47 40 57 71 5.6 71 71 71 64 57 , 50 43 69 6.3 69 69 68 61 54 47 40 72 79 5.7 54 48 41 35 29 - - 73 6.3 53 47 41 35 29 - - 2100 67 79 5.7 65 59 53 47 40 34 28 73 6.3 65 59 52 46 40 34 28 62 69 5.5 69 69 66 60 54 47 41 67 6.3 67 66 63 57 51 45 38 57 67 5.6 67 67 67 61 54 48 42 67 6.3 67 66 63 57 51 45 39 72 74 5.6 50 44 39 34 28 - - 71 6.3 49 43 38 33 27 - - 1800 67 74 5.6 60 55 50 44 39 34 28 71 6.3 59 54 48 43 38 32 27 62 65 5.4 65 65 62 57 51 46 41 65 6.2 65 63 58 53 47 42 37 57 63 5.5 63 63 63 _ 58 52 47 42 65 6.3 65 63 58 53 47 42 37 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Cap: Power Input2 Sensible Capacityl, MBH Total Cap.1 Power Input2 Sensible Capactyl, MBH CFM WB Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F MBH KW MBH KW 72 76 7.1 61 53 45 38 30 - - 75 7.9 59 51 43 36 28 - - 2700 67 71 7.1 70 66 58 50 43 35 27 65 7.8 65 64 56 48 41 33 25 62 64 7.0 64 64 64 56 49 41 34 57 7.8 57 57 57 50 42 34 27 57 64 7.0 64 64 64 56 49 41 34 57 7.7 57 57 57 50 42 34 27 72 76 7.1 59 51 44 37 29 - - 76 7.9 57 49 42 35 27 - - 2550 67 71 7.1 69 64 56 49 42 34 27 66 7.9 66 61 54 47 40 32 25 62 64 7.0 64 64 64 56 49 42 35 58 7.8 58 58 58 51 43 36 29 57 64 7.0 64 64 64 56 49 42 34 58 7.7 58 58 58 50 43 36 29 72 75 7.1 56 49 43 36 29 - - 76 8.0 55 48 41 34 27 - - 2400 67 70 7.1 68 61 54 48 41 34 27 66 7.9 66 59 52 45 38 32 25 62 64 7.0 64 64 63 56 49 42 35 59 7.8 59 59 59 52 45 38 31 57 64 7.0 64 64 63 56 49 42 35 59 7.7 59 59 58 51 44 37 30 72 73 , 7.1 52 45 39 33 27 - - 73 7.9 50 44 37 31 25 - - 2100 67 68 7.1 63 56 50 44 38 32 26 63 7.8 61 54 48 42 36 30 24 62 61 7.0 61 61 58 52 46 40 34 56 7.7 56 56 54 48 42 35 29 57 61 7.0 61 61 58 52 46 40 34 56 7.7 56 56 53 47 41 35 29 72 70 7.1 47 41 36 31 25 - - 69 7.8 45 40 34 29 23 - - 1800 67 65 7.0 57 51 46 41 35 30 25 60 7.8 55 49 44 39 33 28 23 62 59 7.0 59 58 54 48 43 38 32 53 7.7 53 53 49 44 39 33 28 57 59 6.9 59 58 53 48 43 37 32 53 7.6 53 53 49 44 38 33 27 1 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser tan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 7 530.18-TG1 SUPPLY AIR BLOWER PERFORMANCE - DUC036 & 048 with Belt -Drive DUC036 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts - RPM - Watts - • 036 1700 835 705 880 745 923 795 969 860 1013 970 - 1600 811 655 854 695 898 740 942 790 986 840 1029 900 - - 1500 782 610 827 650 871 685 917 730 960 775 1003 825 1046 905 1400 - - 798 595 844 640 889 680 932 720 975 765 1018 790 1300 - - - - 816 590 862 635 907 675 951 715 995 750 1200 - - - - - - 834 585 881 630 927 665 970 705 1100 - - - - - - 809 550 855 590 900 625 942 665 1000 - - - - - - 782 510 829 545 872 858 919 625 900 - - - - - - - - 797 500 843 540 890 580 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM _ Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM - Watts - 036 1700 - - - - - - - - - - - - 1600 - - - - - - - - - - - - - - 1500 - - - - - - - - - - - - - - 1400 1055 875 - - - - - - - - - - _ 1300 1036 780 1066 850 - - - - - - - - - - 1200 1011 735 1047 765 1075 800 - - - - - _ - - 1100 987 690 1028 720 1060 750 1084 775 - - - - - - 1000 963 655 1005 680 1040 695 1068 715 1089 735 - - - - 900 936 615 _ 980 645 1020 660 1050 670 1053 680 1090 690 - - NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DUC048 - SIDE DUCT APPLICATIONS (230/460/575 VOLT MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 1235 048 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts - 048 2000 1103 1270 - - - - - - - - - - _ 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - _ - 1500 1003 945 1044 995 1086 1035 - - - - - - - - 1400 982 880 1024 920 • 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - - NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. 8 Unitary Products Group 530.18-TG1 SUPPLY AIR BLOWER PERFORMANCE - DUC060 & 072 with Belt -Drive DUC060 - SIDE DUCT APPLICATIONS (230/460/575 VOLT MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 060 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - - - - 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500 - - - - - - - - 882 740 926 780 965 830 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 060 2500 - - - - - - - - - - - - - - 2400 1193 1665 - - - - - - - - - - - - 2300 1170 1580 1202 1620 - - - - - - - - - - 2200 1148 1480 1180 1530 - - - - - - - - - - 2100 1121 1385 1155 1425 1190 1475 - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 1205 1445 - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 1222 1375 - - - - 1800 1058 1060 1090 1135 1122 1190 1158 1240 1196 1295 - - - - 1700 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 1197 1205 - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 1198 1150 1500 1004 860 1038 880 1070 925 1101 980 1130 1045 1158 1075 1184 1110 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DUC072 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 072 3200 1150 2325 1182 2425 1212 2525 - - - - - - - - 3000 1100 2010 1129 2090 1157 2150 1185 2225 1215 2290 1242 2360 - - 2800 1045 1700 1074 1780 1102 1850 1131 1940 1160 2025 1190 2075 1217 2130 2600 985 1425 1015 1475 1045 1540 1075 1630 1103 1715 1135 1760 1163 1825 2400 930 1240 958 1300 990 1350 1020 1400 1051 1430 1081 1490 1111 1600 2200 - - 905 1070 933 1160 965 1210 997 1250 1028 1285 1060 1325 2000 - - - - - - 919 1025 950 1100 982 1130 1014 1160 1800 - - - .- - - - - 909 925 939 1005 968 1030 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts - 072 3200 - - - - - - - - - - - - - 3000 - - - - - - - - - - - - - - 2800 1245 2190 - - - - - - - - - - - - 2600 1193 1920 1222 1990 1250 2060 - - - - - - - - 2400 1142 1675 1173 1730. 1205 1800 1234 1885 - - - - - - 2200 1090 1380 1124 1450 1155 1550 1186 1640 1217 1710 1249 1775 - - 2000 1045 1175 1077 1200 1109 1275 1140 1360 1170 1460 1205 1545 1235 1600 1800 998 1050 1028 1060 1058 1060 1087 1075 1118 1150 1148 1250 1176 1360 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. Unitary Products Group 9 530.18-TG1 SUPPLY AIR BLOWER PERFORMANCE - DUC036, 048, 060, 072 with Direct -Drive GAS HEAT& 230/460/575 VOLTS - Side Duct Applications MODEL DUC MOTOR SPEED Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 CFM Watts CFM ,Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts 655 590 545 036 HI MED LOW - 1684 1487 - 800 710 - 1631 1464 - 780 690 1699 1582 1421 825 750 670 1650 1524 1367 785 720 650 1570 1410 1315 755 690 620 1430 1324 1246 725 650 605 1360 1260 1185 700 630 590 1280 1185 1110 680 610 570 1180 1100 1020 048 HI MED LOW 1996 1804 1681 960 838 760 1933 1765 1640 936 810 738 1868 1714 1604 910 785 715 1795 1650 1541 880 765 695 1722 1589 1490 845 735 670 1635 1508 1416 820 705 645 1544 1407 1337 790 675 620 1419 1306 1230 765 645 595 1300 1195 1120 740 625 575 060 HI MED LOW 2400 2290 2150 1155 1105 1020 2338 2214 2100 1125 1065 990 2274 2145 2029 1095 1030 950 2167 2071 1965 1045 990 910 2096 1990 1905 1010 950 880 1990 1911 1816 980 920 838 1887 1828 1724 945 885 800 1771 1724 1644 905 835 770 1629 1604 1531 855 798 710 072 HI 2461 1480 2402 1440 2361 1395 2260 1350 2178 1305 2101 1260 2000 1205 1914 1155 1830 1110 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. FACTORY -INSTALLED OPTION BELT DRIVE BLOWER: Adjustable belt -drive blower, providing maximum flexibility to handle many airflow requirements, is available on 5 ton, single and 3-phase models, and 6 ton, 3-phase models. FIELD -INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide -in / plug-in damper assembly with fully modulating spring return motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be field -assembled before installation. Economizer dampers are 2% low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes slide -in / plug-in damper assembly with 2-position spring -return motor actuator and a rain hood with permanent -type filters. The outdoor air dampers open when the indoor fan motor is energized. The rain hood is shipped knocked down and must be field assembled. BAROMETRIC RELIEF / FIXED OUTDOOR AIR INTAKE AIR DAMPER - A dual function device that consists of a rain hood with a bird screen and a flexible damper. It provides either of the following: 1) a fixed outdoor air intake on units less economizer or 2) barometric relief or units with economizer. The rain hood is fully assembled, painted to match the basic unit and ready for installation. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 30 KW heating are available. FUSE BLOCK KITS - These kits have a fuse box with a fuse block and fuses. They're available for all 460-3-60 volt heaters and 208/230-3-60 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT- A 24-volt thermostat providing two stages of control for units equipped with electric heat accessories. ROOF CURB - This 14" high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be shifted for the desired unit duct arrangement. No insulated deck is required because the unit underside is insulated. START ASSIST KIT - Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a 12.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT - A low ambient controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between 45 and 0°F. ANTI -RECYCLE TIMER - A timer to prevent the units scroll compressor from short cycling. It assures a 5-minute off -time between compressor cycles. PROPANE CONVERSION KIT - Converts a gas -fired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) - Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING - This kit contains 1/2" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut-off. OUTDOOR COIL GUARD - Consists of grille -type sections for installation over the outdoor coil to protect it from damage. WALL THERMOSTAT- The units are designed to operate with 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. 10 Unitary Products Group STATIC RESISTANCES EXTERNAL STATIC P 530.18-TG1 DESCRIPTION RESISTANCE, IWG CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Economizer/Motorized Dampers' 3 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 Electric Heaters.' 5 - 15 KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20 - 30 KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 Bottom Duct Connections.' 0.06 0.07 0.08 0.09 0.10 0.1 1 0.12 0.14 0.16 0.19 0.22 Cooling Onlv2 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.23 0.26 0.29 0.32 Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 2Add these resistance values to the available static resistance in the respective Blower Performance Table. 3The pressure thru the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. MOTOR AND DRIVE DATA - Belt -Drive Blower MODEL BLOWER RANGE (RPM) MOTOR* ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT HP RPM FRAME SIZE SERVICE FACTOR PITCH DIA. (in) BORE (in.) PITCH DIA. (in.) BORE (in.) PITCH LENGTH (in.) DESIG- NATION DHB / DUC 036 790 - 1120 11/2 1725 56 1.15 2.4 - 3.4 7/8 - 5.7 1 37.3 A36 DHB / DUC 048 790 - 1120 11/2 1725 56 1.15 2.4 - 3.4 7/8 5.7 1 37.3 A36 DHB / DUC 060 850 - 1220 11/2 1725 56 1.15 2.4 - 3.4 7/8 5.2 1 37.3 A36 DHB / DUC 072 900 - 1250 11/2 1725 56 1.15 2.8 - 3.8 7/8 _ 5.2 1 37.3 A36 *AII motors have solid bases and are inherently protected. These motors can be selected o operate into their service factor because they are located in the moving air, upstream of any heating device. ELECTRICAL DATA - Basic Units with Direct -Drive MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA 036 208/230-1-60 208/230-3-60 460-3-60 575-3-60 187 187 414 518 253 253 504 630 18.0 11.4 6.2 5.0 105.0 90.0 45.0 36.0 1.3 1.3 0.8 0.8 4.4 4.4 2.2 2.2 28.2 20.0 10.8 9.3 45 30 15 15 45 30 15 - 048 208/230-1-60 208/230-3-60 460-3-60 575-3-60 187 187 414 518 253 253 504 630 24.4 14.1 7.1 5.6 140.0 105.0 55.0 44.0 1.3 1.3 0.8 0.8 5.0 5.0 2.2 2.2 36.8 23.9 11.9 10.1 60 35 15 15 60 35 15 - 060 208/230-1-60 208/230-3-60 460-3-60 575-3-60 187 187 414 518 253 253 504 630 28.9 16.0 8.0 6.4 165.0 125.0 67.0 50.0 1.3 1.3 0.8 0.8 6.6 6.6 3.3 3.3 44.0 27.9 14.1 12.1 70 40 20 15 70 40 20 - 072 208/230-3-60 460-3-60 575-3-60 187 414 518 253 504 630 _ 20.3 10.2 8.2 146.0 73.0 58.4 1.3 0.8 0.8 6.8 3.6 3.6 33.5 17.2 14.7 50 25 20 50 25 - NOTES: 1. Utilization Range "A" in accordance with ARI Standard 1 0. 2. Dual element, time delay type. ELECTRICAL DATA - Basic Units with Belt -Drive MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, (SEENOTE2) AMPS MAX. HACR BREAKER SIZE, AMPS 45 30 15 - MIN. MAX. RLA LRA 036 208/230-1-60 208/230-3-60 460-3-60 575-3-60 187 187 414 518 253 253 504 630 18.0 11.4 6.2 5.0 105.0 90.0 45.0 36.0 1.3 1.3 0.8 0.8 5.3 5.3 3.1 3.1 29.1 20.9 11.7 10.2 45 30 15 15 048 208/230-1-60 208/230-3-60 460-3-60 575-3-60 187 187 414 518 253 253 504 630 24.4 14.1 7.1 5.6 140.0 105.0 55.0 44.0 1.3 1.3 0.8 0.8 8.6 5.2 2.6 2.0 40.4 24.1 12.3 9.9 60 35 15 15 60 35 15 - 060 208/230-1-60 208/230-3-60 460-3-60 575-3-60 187 187 414 518 253 253 504 630 28.9 16.0 8.0 6.4 165.0 125.0 67.0 50.0 1.3 1.3 0.8 0.8 8.6 6.0 3.0 2.4 46.0 27.3 13.8 11.2 70 40 20 15 70 40 20 - 072 208/230-3-60 460-3-60 575-3-60 187 414 518 253 504 630 20.3 10.2 8.2 146.0 73.0 58.4 1.3 0.8 0.8 7.3 3.7 2.8 _ 34.0 17.3 13.9 50 25 20 50 25 - NOTES: 1. Utilization Range "A" in acco dance with ARI Standard 110. Unitary Products Group 2. Dual element, time delay type. 11 530.18-TG 1 ELECTRICAL DATA - Cooling / Electric Heating (DHB036 & 048) with Direct -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MAX FUSE SIZE1 AMPS MAX. SIZE HACK 2 BREAKER AMPS KW STAGES TOTAL AMPS MINIMUM CIRCUIT AMPACITY 2CE04500506 4.0 1 19.1 29.4 45 45 2CE04500706 5.6 1 27.1 39.4 45 45 208-1-60 2CE04501006 4.4 8.0 1 38.3 53.3 60 60 2CE04501506 11.9 2 57.4 77.3 80 80 2CE04502006 15.9 2 76.6 101.2 110 110 2CE04500506 5.3 1 22.1 33.1 45 45 2CE04500706 7.5 1 31.3 44.6 45 45 230-1-60 2CE04501006 4.4 10.6 1 44.2 60.7 70 70 2CE04501506 15.9 2 66.3 88.3 90 90 2CE04502006 21.2 2 88.3 115.9 125 125 2CE04500525* 4.0 1 11.0 20.0 30 30 2CE04500725* 5.6 1 15.6 25.0 30 30 036 208-3-60 2CE04501025 2CE04501525 4.4 8.0 11.9 1 2 22.1 33.1 33.1 46.9 35 50 35 50 2CE04502025 15.9 2 44.2 60.7 70 70 2CE04500525* 5.3 1 12.7 21.4 30 30 2CE04500725* 7.5 1 18.0 28.1 30 30 230-3-60 2CE04501025 4.4 10.6 1 25.5 37.4 40 40 2CE04501525 15.9 2 38.2 53.3 60 60 2CE04502025 21.2 2 51.0 69.2 70 70 2CE04500746* 6.8 1 8.2 13.0 15 15 460-3-60 2CE04501046" 2CE04501546* 2'2 10.1 13.6 1 1 12.1 16.4 17.9 23.2 20 25 20 25 2CE04502046* 19.5 2 23.5 32.1 35 35 2CE04501058 10.6 1 10.2 15.5 20 - 575-3-60 2CE04501558 2.2 15.9 1 15.3 21.9 25 - 2CE04502058 21.2 2 20.4 28.2 30 - 2CE04500506 4.0 1 19.1 36.8 60 60 2CE04500706 5.6 1 27.1 40.1 60 60 208-1-60 2CE04501006 5.0 8.0 1 38.3 54.1 60 60 2CE04501506 11.9 2 57.4 78.0 80 80 2CE04502006 15.9 2 76.6 101.9 110 110 2CE04500506 5.3 1 22.1 36.8 60 60 2CE04500706 7.5 1 31.3 45.3 60 60 230-1-60 2CE04501006 5.0 10.6 1 44.2 61.5 70 70 2CE04501506 15.9 2 66.3 89.1 90 90 2CE04502006 21.2 2 88.3 116.7 125 125 2CE04500525* 4.0 1 11.0 23.9 35 35 2CE04500725* 5.6 1 15.6 25.8 35 35 048 208-3-60 2CE04501025 2CE04501525 5.0 8.0 11.9 1 2 22.1 33.1 33.9 47.7 35 50 35 50 2CE04502025 15.9 2 44.2 61.5 70 70 2CE04500525* 5.3 1 12.7 23.9 35 35 2CE04500725* 7.5 1 18.0 28.8 35 35 230-3-60 2CE04501025 5.0 10.6 1 25.5 38.1 40 40 2CE04501525 15.9 2 38.2 54.1 60 60 2CE04502025 21.2 2 51.0 70.0 70 70 2CE04500746* 6.8 1 8.2 13.0 15 15 2CE04501046* 10.1 1 12.1 17.9 20 20 460-3-60 2CE04501546* 2'2 13.6 1 16.4 23.2 25 25 2CE04502046* 19.5 2 23.5 32.1 35 35 2CE04501058 10.6 1 10.2 15.5 20 - 575-3-60 2CE04501558 2.2 15.9 1 15.3 21.9 25 -- 2CE04502058 21.2 2 20.4 28.2 30 - Dual element, time delay type 2 Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. * These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Electric Heat Correction Factors Nominal Voltage 208 240 Voltage 208 230 KW Cap Multipier 1.00 0.92 0.92 .92 480 460 600 575 0 Fuse Block is 2FB04700425 208/240 Volts 2FB04700546 460 Vol 12 Unitary Products Group 530.18-TG1 ELECTRICAL DATA - Cooling / Electric Heating (DHB060 & 072) with Direct -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA , ELECTRIC HEATERS MAX. FUSE AMPS MAX. SIZE HACR2 BREAKER AMPS KW STAGES TOTAL AMPS MINIMUM CIRCUIT AMPACITY 2CE04500506 4.0 1 19.1 44.0 70 70 2CE04500706 5.6 1 27.1 44.0 70 70 2081-60 2CE04501006 2CE04501506 66 ' 8.0 11.9 1 2 38.3 57.4 56.1 80.0 70 90 70 90 2CE04502006 15.9 2 76.6 103.9 110 110 2CE04503006 22.2 2 106.9 141.9 150 150 2CE04500506 5.3 1 22.1 44.0 70 70 2CE04500706 7.5 1 31.3 47.3 70 70 230-1-60 2CE04501006 6 6 10.6 1 44.2 63.5 70 70 2CE04501506 15.9 2 66.3 91.1 100 100 2CE04502006 21.2 2 88.3 118.7 125 125 2CE04503006 29.6 2 123.3 162.4 175 175 2CE04500525* 4.0 1 11.0 27.9 40 40 2CE04500725* 5.6 1 15.6 27.9 40 40 208-3-60 2CE04501025 6 6 8.0 1 22.1 35.9 40 40 060 2CE04501525 2CE04502025 11.9 15.9 2 2 33.1 44.2 49.7 63.5 50 70 50 70 2CE04503025 22.2 2 61.7 85.4 90 90 2CE04500525* 5.3 1 12.7 27.9 40 40 2CE04500725* 7.5 1 18.0 30.8 40 40 230-3-60 2CE04501025 2CE04501525 66 ' 10.6 15.9 1 2 25.5 38.2 40.1 56.1 45 60 45 60 2CE04502025 21.2 2 51.0 72.0 80 80 2CE04503025 29.6 2 71.2 97.3 100 100 2CE04500746* 6.8 1 8.2 14.3 20 20 2CE04501046* 10.1 1 12.1 19.3 20 20 460-3-60 2CE04501546* 3.3 13.6 1 16.4 24.6 25 25 2CE04502046* 19.5 2 23.5 33.4 35 35 2CE04503046* 28.8 2 34.6 47.4 50 50 2CE04501058 10.6 1 10.2 16.9 20 - 575 3 60 2CE04501558 3'3 15.9 1 15.3 23.2 25 2CE04502058 21.2 2 20.4 29.6 30 - 2CE04503058 30.4 2 29.3 40.7 45 - 2CE04500525* 4.0 1 11.0 33.5 50 50 2CE04500725* 5.6 1 15.6 33.5 50 50 208-3-60 2CE04501025 2CE04501525 6'8 8.0 11.9 1 2 22.1 33.1 36.1 49.9 50 50 50 50 2CE04502025 15.9 2 44.2 63.7 70 70 2CE04503025 22.2 2 61.7 85.6 90 90 2CE04500525* 5.3 1 12.7 33.5 50 50 2CE04500725* 7.5 1 18.0 33.5 50 50 230-3-60 2CE04501025 6'8 10.6 1 25.5 40.4 50 50 2CE04501525 15.9 2 38.2 56.3 60 60 072 2CE04502025 21.2 2 51.0 72.2 80 80 2CE04503025 29.6 2 71.2 97.5 100 100 2CE04500746* 6.8 1 8.2 17.2 25 25 2CE04501046* 10.1 1 12.1 19.7 25 25 460-3-60 2CE04501546* 3.6 13.6 1 16.4 24.9 25 25 2CE04502046* 19.5 2 23.5 33.8 35 35 2CE04503046* 28.8 2 34.6 47.8 50 50 2CE04501058 10.6 1 10.2 17.2 20 - 575 3 60 2CE04501558 3 6 15.9 1 15.3 23.6 25 - 2CE04502058 21.2 2 20.4 30.0 30 - 2CE04503058 30.4 2 29.3 41.1 45 - 1 Dual element, time delay type 2 Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. " These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Electric Heat Correction Factors Nominal Voltage 208 240 480 Voltage 208 230 460 KW Cap Multipier 1.00 0.92 0.92 a2 600 575 n Fuse Block 208/240 Volts 460 V Unitary Products Group 13 53018-TG 1 ELECTRICAL DATA - Cooling / Electric Heating (DHB036 & 048) with Belt -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE1 AMPS MAX. SIZE HACK 2 BREAKER AMPS KW STAGES TOTAL AMPS 2CE04500506 4.0 1 19.1 30.5 45 45 2CE04500706 5.6 1 27.1 40.5 45 45 208-1-60 2CE04501006 5.3 8.0 1 38.3 54.5 60 60 2CE04501506 11.9 2 57.4 78.4 80 80 2CE04502006 15.9 2 76.6 102.3 110 110 2CE04500506 5.3 1 22.1 34.2 45 45 2CE04500706 7.5 1 31.2 45.7 50 50 230-1-60 2CE04501006 5.3 10.6 1 44.2 61.8 70 70 2CE04501506 15.9 2 66.3 89.4 90 90 2CE04502006 21.2 2 88.3 117.0 125 125 2CE04500525* 4.0 1 11.0 20.9 30 30 2CE04500725* 5.6 1 15.6 26.2 30 30 036 208-3-60 2CE04501025 2CE04501525 5.3 8.0 11.9 1 2 22.1 33.1 34.2 48.1 35 50 35 50 2CE04502025 15.9 2 44.2 61.9 70 70 2CE04500525* 5.3 1 12.7 22.6 30 30 2CE04500725* 7.5 1 18.0 29.2 30 30 230-3-60 2CE04501025 5.3 10.6 1 25.5 38.5 40 40 2CE04501525 15.9 2 38.2 54.4 60 60 2CE04502025 21.2 2 51.0 70.4 80 80 2C E04500746* 6.8 1 8.2 14.1 15 15 460-3-60 2CE04501046* 2CE04501546* 3'1 10.1 13.6 1 1 12.1 16.4 19.1 24.3 20 25 20 25 2CE04502046* 19.5 2 23.5 33.2 35 35 2CE04501058 10.6 1 10.2 16.6 20 -- 575-3-60 2CE04501558 3.1 15.9 1 15.3 23.0 25 - 2CE04502058 21.2 2 20.4 29.4 30 - 2CE04500506 4.0 1 19.1 40.4 60 60 2CE04500706 5.6 1 27.1 44.6 60 60 208-1-60 2CE04501006 8.6 8.0 1 38.3 58.6 60 60 2CE04501506 11.9 2 57.4 82.5 90 90 2CE04502006 15.9 2 76.6 106.4 110 110 2CE04500506 5.3 1 22.1 40.4 60 60 2CE04500706 7.5 1 31.3 49.8 60 60 230-1-60 2CE04501006 8.6 10.6 1 44.2 66.0 70 70 2CE04501506 15.9 2 66.3 93.6 100 100 2CE04502006 21.2 2 88.3 121.2 125 125 2CE04500525* 4.0 1 11.0 24.1 35 35 2CE04500725' 5.6 1 15.6 26.0 35 35 208-3-60 2CE04501025 5.2 8.0 1 22.1 34.1 35 35 048 2CE04501525 11.9 2 33.1 47.9 50 50 2CE04502025 15.9 2 44.2 61.7 70 70 2CE04500525' 5.3 1 12.7 24.1 35 35 2CE04500725* 7.5 1 ' 18.0 29.1 35 35 230-3-60 2CE04501025 5.2 10.6 1 25.5 38.4 40 40 2CE04501525 15.9 2 38.2 54.3 60 60 2CE04502025 21.2 2 51.0 70.2 80 80 2CE04500746' 6.8 1 8.2 13.5 15 15 460-3-60 2CE04501046` 10.1 1 12.1 18.4 20 20 2CE04501546* 2'6 13.6 1 16.4 23.7 25 25 2CE04502046* 19.5 2 23.5 32.6 35 35 2CE04501058 10.6 1 10.2 15.2 20 - 575-3-60 2CE04501558 2.0 15.9 1 15.3 21.6 25 - 2CE04502058 21.2 2 20.4 28.0 30 - 1 Dual element, time delay type 2 Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Electric Heat Correction Factors Nominal Voltage Voltage 208 240 480 600 208 230 460 575 KW Cap Multipier 1.00 0.92 0.92 1..2 2FB04700425 2FB04700546 208/240 Volts aFn voir� 14 Unitary Products Group 530.18-TG1 ELECTRICAL DATA - Cooling / Electric Heating (DHB060 & 072) with Belt -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MAX. SIZES AMPS MAX. SIZE HACR2 BREAKER AMPS KW STAGES TOTAL AMPS MINIMUM CIRCUIT AMPACITY 2CE04500506 4.0 1 19.1 46.0 70 70 2CE04500706 5.6 1 27.1 46.0 70 70 2081-60 2CE04501006 8'6 8.0 1 38.3 58.6 70 70 2CE04501506 11.9 2 57.4 82.5 90 90 2CE04502006 15.9 2 76.6 106.4 110 110 2CE04503006 22.2 2 106.9 144.4 150 150 2CE04500506 5.3 1 22.1 46.0 70 70 2CE04500706 7.5 1 31.3 49.8 70 70 230160 2CE04501006 2CE04501506 86 ' 10.6 15.9 1 2 44.2 66.3 66.0 93.6 70 100 70 100 2CE04502006 21.2 2 88.3 121.2 125 125 2CE04503006 29.6 2 123.3 164.9 175 175 2CE04500525* 4.0 1 11.0 27.3 40 40 2CE04500725* 5.6 1 15.6 27.3 40 40 208-3-60 2CE04501025 2CE04501525 60 ' 8.0 11.9 1 2 22.1 33.1 35.1 48.9 40 50 40 50 060 2CE04502025 15.9 2 44.2 62.7 70 70 2CE04503025 22.2 2 61.7 84.6 90 90 2CE04500525* 5.3 1 12.7 27.3 40 40 2CE04500725* 7.5 1 18.0 30.1 40 40 230-3-60 2CE04501025 6 0 10.6 1 25.5 39.4 40 40 2CE04501525 15.9 2 38.2 55.3 60 60 2CE04502025 21.2 2 51.0 71.2 80 80 2CE04503025 29.6 2 71.2 96.5 100 100 2CE04500746* 6.8 1 8.2 14.0 20 20 2CE04501046* 10.1 1 12.1 18.9 20 20 460-3-60 2CE04501546* 3.0 13.6 1 16.4 24.2 25 25 2CE04502046* 19.5 2 23.5 33.1 35 35 2CE04503046* 28.8 2 34.6 47.1 50 50 2CE04501058 10.6 1 10.2 15.7 20 -- 575-3-60 2CE04501558 2 4 15.9 1 15.3 22.1 25 - 2CE04502058 21.2 2 20.4 28.5 30 - 2CE04503058 , 30.4 2 29.3 39.6 40 - 2CE04500525* 4.0 1 11.0 34.0 50 50 2CE04500725* 5.6 1 15.6 34.0 50 50 208-3-60 2CE04501025 7'3 8.0 1 22.1 36.7 50 50 2CE04501525 11.9 2 33.1 50.6 60 60 2CE04502025 15.9 2 44.2 64.4 70 70 2CE04503025 22.2 2 61.7 86.3 90 90 2CE04500525* 5.3 1 12.7 34.0 50 50 2CE04500725* 7.5 1 18.0 34.0 50 50 230-3-60 2CE04501025 7 3 10.6 1 25.5 41.0 50 50 2CE04501525 15.9 2 38.2 56.9 60 60 072 2CE04502025 21.2 2 51.0 72.9 80 80 2CE04503025 29.6 2 71.2 98.1 100 100 2CE04500746* 6.8 1 8.2 17.3 25 25 2CE04501046* 10.1 1 12.1 19.8 25 25 460-3-60 2CE04501546* 3.7 13.6 1 16.4 25.1 30 30 2CE04502046* 19.5 2 23.5 33.9 35 35 2CE04503046* 28.8 2 34.6 47.9 50 50 2CE04501058 10.6 1 10.2 16.2 20 - 575-3-60 2CE04501558 2'8 15.9 1 15.3 22.6 25 2CE04502058 21.2 2 20.4 29.0 30 - 2CE04503058 30.4 2 29.3 40.1 45 - 1 Dual element, time delay type 2 Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. * These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Electric Heat Correction Factors Nominal Voltage 208 240 480 600 Voltage 208 230 460 575 KW Cap Multi.ier 1.00 0.92 0.92 1•2 Fuse Block 2FB04700425 :r 208/240 Volts 460 Volts Unitary Products Group 15 530.18-TG1r FIELD WIRING T GROUND LUG CONTACTOR TYPICAL POWER WIRING FIELD -SUPPLIED DISCONNECT r "I SINGLE -1--0' LQ--r-> PHASE -0-0--> POWER L J SUPPLY REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTEC- TION AND WIRING. CONTACTOR T I I GROUND L LUG I I L FIELD -SUPPLIED DISCONNECT 2 F PHASE o- - L. > POWER L SUPPLY TYPICAL CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT1 UN TTERMINAL TERMINALS STRIP TB1 o- 24 VOLT TRANSFORMER 24 VOLT THERMOSTAT 6TH08701024. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER J1 FROM TERMINALS 8 AND 10 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE SCROLL COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT 6TH04702124. COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT1 TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER 24 VOLT THERMOSTAT 6TH07700124. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER J1 FROM TERMINALS 8 AND 10 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE SCROLL COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING OR HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 6TH04702024. 16 Unitary Products Group UNIT DIMENSIONS (DHB AND DUC - 3, 4, 5 & 6 TON) CONTROL BLOWER FIELD -SUPPLIED BOX ACCESS DISCONNECT SWITCH ACCESS LOCATION (Direct -Drive units) DHB UNITS 3-6TON 3f4" PVC FEMALE COND. DRAIN (See Detail "A") BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B - POWER WIRING ENTRY A - CONTROL WIRING ENTRY 8-3(8 SCROLL COMPRESSOR ACCESS UNIT BASE WITH RAILS Shown separately to Illustrate bottom duct openings and power connection locations. NOTE For curb -mounted unite, refer to the duct hanger dimensions of the curb tor the proper size of the supply and return air duct oonnecticne. FIELD -SUPPLIED DISCONNECT SWITCH LOCATION (Direct -Drive units) T FILTER ACCESS---- 32-5/8 DUC UNITS 3-6TON 314" PVC FEMALE COND. DRAIN (See Detail "A") 538 44-7/8, A, 8 WIRING ENTRY (See Detail "B") BOTTOM SUPPLY 8 RETURN AIR OPENINGS (SEE NOTE) 8 - POWER WIRING ENTRY A - CONTROL WIRING ENTRY CONTROL BOX ACCESS BLOWER ACCESS FRONT VIEW 0 VENT AIR OUTLET HOOD CONDENSER 1 SCROLL COMPR. ACCESS 43r8 -..- 7 -,.___.t- GAS HEAT C ACCESS GAS SUPPLY ENTRY -1l4 (1/2" NPTI AT GAS VALVE) 32-1/4 82 // 1 D GAS SUPPLY ENTRY (1/p" NPTI AT GAS VALVE) 32-114 UNIT BASE WITH RAIL Shown separately to Illustrate bottom duct openings. power and gee piping connection bcadons. NOTE: For curb -mounted unite. refer to the duct hanger dimensions of the curb for the proper size of the supply and return air duct connections. 530.18-TG1 All dimensions are in inches. They are subject to change without notice. Certified dimensions wil be provided upon request. RLTER AMECS BLOWER MOTOR ACCESS FIELD -SUPPLED DISCONNECT SWITCH LOCATION BRACKET FOR DISCONNECT SWATCH (Shipped attached to the blower hawing Faye the blows, cmnpa"ment) WIRING ENTRY (See Detect •B•) 1, t r• .IIiS111•tY-laed11:1 W ya•13rT ll UTILITIES ENTRY DATA CONTROL BOX ACCESS HOLE KNOCKOUT SIZE (DIA.) USED FOR A 7/8" * Control Wiring (Side or Bottom)** Power Wiring (Side or Bottom) B 2„ , C 1-5/8" Gas Piping (Front) D 1-1/2" Gas Piping (Bottom) "Knockouts in the bottom of the unit can be located by the slice in the insulation. *"Do 501 remove the 2" knockout ring. CLEARANCES Front DHB Units 24" DUC Units 32" Back 12" (Less Economizer) 36" (With Economizer) 24" (Less Economizer) 36" (With Economizer) Left Side (Filter Access) Right Side (Cond. Coil) 24 Below Unit.' 0" Above Unit2 72" (For Condenser Air Discharge) 1 Units may be installed on combustible floors made from COMBUSTION AIR wood or class A, B or C roof covering material. INLET HOOD 2 Units must be installed oudoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. NOTES: DHB Models: Units and ductwork are approved for zero clear- ance to combustible materials when equipped with electric heaters. DUC Mode,(',: A 1" clearance must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. r 2.112 Locate unit so that the vent air outlet hood is at least: • Three (3) feet above any forced air inlet located within 10 horizontal feet (excluding those integral to the unit). • Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity air inlet into the building. • Four (4) feet from electric meters, gas meters, regualtors and relief equipment. RETURN AIR SUPPLY AIR CONDENSER AIR OUTDOOR AIR (Economizer) Unitary Products Group 17 530.18-TG1 UNIT DIMENSIONS - CONT'D. (DHB and DUC - 3, 4, 5 & 6 TON) SIDE SUPPLY AND RETURN AIR DUCT OPENINGS a5/8 77/8 DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remove the side supply air duct cover to gain access to the bottom supply air knockout panel. 2. Remove and discard the bottom knockout panel. 3. Replace the side duct cover. 4. With filter section access panel removed from the unit, remove and discard the bottom return air knockout panel. 5. Replace the filter access panel. REAR VIEW 15/8 271/2 191/2 DETAIL "A" UNIT WITH ECONOMIZER RAINHOOD 447/8 L.H. END VIEW 3/4" CONDENSAT DRAIN CONN. Must be trapped) REAR VIEW 447/8 L.H. END VIEW DETAIL "B" UNIT WITH FIXED OUTDOOR AIR / BAROMETRIC RELIEF RAINHOOD B APPROXIMATE CENTER OF GRAVITY BACK FRONT 821/4 A DIM. A B 3-5TON 19-3/4" 40-3/4" CONDENSER COIL END OF UNIT 6 TON 22" 44" CENTER OF GRAVITY 18 Unitary Products Group BACK OF UNIT SUPPLY* AIR RETURN' AIR 19-1/2" 37-1/4" DUCT SIZES: Supply Air .19" x 19" Return Air = 19" x 19" UNIT AND CURB APPLICATION 530.18-TG1 ROOF CURB DIMENSIONS - (DHB and DUC - 3, 4, 5 & 6 TON) SCROLL COMPRESSOR DUCT 2" TYP. AND CONDENSER END SUPPORT RAILS � OF UNIT 73" FRONT OF UNIT 'Supply and Return Air (including duct support rails) shown are typical for bottom duct applications. For location of biXizontai duct applications (on back of unit), refer to Unit Dimension details. 3/4" X 1-1/4" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE- ; 7 WOOD NAILER— UNIT BASE RAILS 14„ —._W.. 8" MIN. ABOVE FINISHED ROOF — ' COUNTERFLASHING CURB FRAME— CANT STRIP INSULATION AND ROOFING MATERIAL INSULATION ROOF DECK AND SUPPORT STRUCTURE Unitary Products Group 19 TYPICAL APPLICATIONS 1 I I L J ROOF JACK INSTALLATION ROOF CURB / INSTALLATION 1 1 1 1 1 1 1 1 1 1 I I 1 1 1 I I 1 I I I I I 1 1 1 1 f 1 I . 1 1 1 1 1 1 1 1 1 I f SLAB ON GROUND INSTALLATION 1 L-... 0O TYPICAL ROOF -TOP INSTALLATION (MODEL DUC SHOWN) FIELD -SUPPLIED DISCONNECT SWITCH J. T CONDENSATE �AP TO CONTROL WIRING POWER TO INDOOR SUPPLY THERMOSTAT EFFICIENCY RATING CERTIFIED ama 208/230-1-60 VOLT MODELS ONLY LLGGO/!lE SUPPLY AIR DUCT RETURN AIR DUCT MANUAL GAS SHUT.OFF VALVE ROOF CURB TO GAS SUPPLY LINE eNN 208/230, 460 VOLT MODELS ONLY 208/230, 575 VOLT MODELS ONLY ISO 9001 CERTIFIED 530.18-TG 1 F Healing. Al, Canumanfng Supersedes: 530.18-TG1L (295) and Supl. 1 (696) Subject to change without notice. Printed in U.S.A. Unitary Products Group 745 Industrial Parkway Elyria, OH, 44035 BTL FILE COPY ENC;INEERINCG 19011 Woodinville — Snohomish Road NE, Suite 100 Woodinville, WA 98072-4436 Phone: (425) 814-8448 Fax: (425) 821-2120 Structural Calculations for Summit Surgical Andover Executive Park Building 10 GP-1 Replacement 633 Industry Drive Tukwila, WA 98188 October 13th, 2014 t411-1- 0(415 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 3 2014 City of Tukwila BUILDING DIVISION 10.13.14 RECEIVED CITY OF TUKWILA OCT 1 3 2014 PERMIT CENTER BOB Wao3& hood kik HD ThatSivale,Wit 910124w Phoorigl MOM Fit (425)1121 120 Calculations 19011 +Smtoed NE,Saioe100 Voxforwale.WA 1073443i Apes ( S) t14{441 Fam N25) $21.1ZD Gravity Support 16`X4'W CLULAM BEAM, 101-0' OC; lYP (E) ROOF CURB wow mom, 474" IRON 1876'W GLULAM BEAM. 20' @' OC; lYP GLULAM BEAM (N) CURB ADAPTER NCWP ANDOVER EXECUTIVE PARK BLDG 10 PARTIAL ROOF SCALE: 1 /8" = 1' - 0" • ENGINEERING 19011 Wood-Sno Road NE, Suite 100 Woodinville, WA 98072-4436 Phone:425-814-8448 Fax: 425-821-2120 FULIow PLiL ) Project: Project Number: Client: Designed By: Date: _2 Scale: Page. DOUGLAS FIR 24F - V4 Fb = F„ = E_ Fcs = 2400 psi 265 psi 1800 ksi 650 psi b x d (in) (in) Manow (ft-k) = Fti *S Vance, (k) = 2/3 * Fv' * b * d El I (in") S (in'') Cva Co =1.0 I =1.15I =1.33 Co =1.0 I =1.15I =1.33 (Ib-in` x 10u) 31 /8 x 6 3.75 4.31 5.00 3.31 3.81 4.42 101.25 56.25 18.75 1.00 31/8 x 71/2 5.86 6.74 7.81 4.14 4.76 5.52 197.75 109.86 29.30 1.00 31/8 x 9 8.44 9.70 11.25 4.97 5.71 6.63 341.72 189.84 42.19 1.00 31 /8 x 101 /2 11.48 13.21 15.31 5.80 6.67 7.73 542.64 301.46 57.42 1.00 31 /8 x 12 15.00 17.25 20.00 6.63 7.62 8.83 810.00 450.00 75.00 1.00 31 /8 x 131 /2 18.98 21.83 25.31 7.45 8.57 9.94 1,153.30 640.72 94.92 1.00 31/8 x 15 23.44 26.95 31.25 8.28 9.52 11.04 1,582.03 878.91 117.19 1.00 31/8 x 161/2 27.85 32.03 37.14 9.11 10.48 12.15 2,105.68 1169.82 141.80 0.98 31/8 x 18 32.86 37.79 43.81 9.94 11.43 13.25 2,733.75 1518.75 168.75 0.97 31 /8 x 191 /2 38.26 44.00 51.01 10.77 12.38 14.35 3,475.72 1930.96 198.05 0.97 31 /8 x 21 44.04 50.65 58.72 11.59 13.33 15.46 4,341.09 2411.72 229.69 0.96 31 /8 x 221 /2 50.21 57.74 66.95 12.42 14.29 16.56 5,339.36 2966.31 263.67 0.95 31/8 x 24 56.76 65.27 75.68 13.25 15.24 17.67 6,480.00 3600.00 300.00 0.95 31 /8 x 251 /2 61.88 71.17 82.51 14.08 16.19 18.77 7,772.52 4318.07 338.67 0.91 31/8 x 27 68.98 79.33 91.98 14.91 17.14 19.88 9,226.41 5125.78 379.69 0.91 31 /8 x 281 /2 76.45 87.91 101.93 15.73 18.09 20.98 10,851.15 6028.42 423.05 0.90 31/8 x 30 84.27 96.91 112.36 16.56 19.05 22.08 12,656.25 7031.25 468.75 0.90 31 /8 x 31 1 /2 92.46 106.32 123.28 17.39 20.00 23.19 14,651.19 8139.55 516.80 0.89 31/8 x 33 98.77 113.59 131.70 18.22 20.95 24.29 16,845.47 9358.59, 567.19 0.87 31/8 x 341/2 107.48 123.60 143.30 19.05 21.90 25.40 19,248.57 10693.65 619.92 0.87 31/8 x 36 H 116.531 134.011 155.37 19.881 22.861 26.501 21,870.00 12150.00 675.001 0.86 aThe preceding table assumes the following values. Refer to 2001 NDS 5.3.2 to determine actual Cv. Cv = (21/L)" (12/d)' (5.125/b)"" 51.0 x= 10 L <_ 20' for depths up to 15" 20' 5 L 5 30' for depths up to 24" 30' <_ L 5 40' for depths up to 31 %i' 40' <_ L _< 50' for depths up to 36" �-3 9011 Wood -Soo lad LIE„Etiic 100 Ifte widi;AA NO7Z4i36 PbaC(c5) S1WN6 (42411121,2129 Seismic Support Print - Maps Page 1 of 1 b bing Maps 633 Industry Dr, Tukwila, WA 98188 My Notes On the go? Use m.bing.com to fmd maps, directions, businesses, and more Bryn Mawr Boulevard Parr Skyway ;'• 'Renton Riverton . Tukwila SeaTac httn•//urxnry hinn rnm/mane Ir►riri$ oorw7mtr+=exr._„eX,.7=1 7 52,e=1,p.....—d"7 AS')O1C 1 77 ' A1'7 1 A/1 1 /')/11 A Design Maps Summary Report Page 1 of 2 MUM Design Maps Summary Report User -Specified Input Report Title Summit Surgical - Andover Executive Park Sat October 11, 2014 17:41:38 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.45293°N, 122.2477°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.443 g Si = 0.537 g SMs = 1.443 g SM1 = 0.806 g S. = 0.962 g Sol = 0.537 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.13 1.50 1.35 1.20 1.05 a O� 0.30 e.. 0.75 to 0.60 0.45 0.20 0.15 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.00 1.00 1.20 1.40 1.60 1.00 Period, T (sec) 2.00 1.10 1.00 0.50 0.00 0.70 cI 0.00 a 0.50 0.40 0.30 0.20 0.10 0.00 Design Response Spectrum 0.00 0.20 0.40 0.00 0.00 1.00 1.20 1.40 1.60 1.00 2.00 Period T (sec) hffrt•/Jahn'2_Part nil alra trrr rre rre rrAtriA.oi h... J..,,rr,rrrorar 1 AJ1 1 /'1A1 A Summit Surgical 14-341-07 Revision Date: 10/11/2014 Occupancy Category: Seismic Use Group: I IE = 1.00 /s = 1.00 I„, = 1.00 II - Other Structures Ss = 1.443 Si=0.537 (Seismic Factor) (Snow Factor) (Wind Factor) IBC Table 1604.5 Site Class: v ASCE Table 20.3-1 Fe = 1.00 F„ = 1.50 ASCE Table 11.4-1 ASCE Table 11.4-2 Design Spectral Response Acceleration: SMs = FaSs = 1.44 SDS=2'3SMS = 0.96 SMI=FvS1 = 0.81 SDI = % SM1 = 0.54 Summit Surgical 14-341-07 Revision Date: 10/11/2014 UNtTO /OAPTe. Seismic Forces Component Operating Weight: 597 Ibs Fp = 0.4 ap SDS WP [1+2 (zlh)] Rp/ Ip Fp = 287 Ibs Fp need not exceed: Fp = 1.6 Sus IP Wp Fp = 919 ibs Fp shall not be Less than: Fp = 0.3 SOS Ip Wp Fp = 172 lbs Dimensions: x = 44 in y= 74.4 in z = 33.4 in Curb Height = 0 in Check Uplift: Mar = 4796 lb -in MRESIST = 11821 lb -in x FP r' k Curb Height, Ip = zlh= ASCE Eq. 13.3-1 ASCE Eq. 13.3-2 ASCE Eq. 13.3-3 y F.S. = 2.5 1.5 O.K. J 5- 4 Summit Surgical 14-341-07 Revision Date: 10/11/2014 Seismic Forces /QAP'ri2 ¶o 1-1 S'f(,t (s Gut24 Component Operating Weight: 597 ' Ibs Fp = 0.4 ap Sin Wp Rp/ Ip Fp = 287 Ibs F p need not exceed: Fp = 1.6 Sos Ip Wp Fp = 919 Ibs F p shall not be less than: Fp = 0.3 Sin Ip Wp Fp = 172 Ibs Dimensions: ap=; 2• 5; Rp Ip = z/h= [1+2 (z/h)] ASCE Eq. 13.3-1 ASCE Eq. 13.3-2 ASCE Eq. 13.3-3 x f—� x = 44 in FP y 74.4 in z z= 33.4 in w� Curb Height = 22 in Curb Height Check Uplift: MOT = 11113 lb -in MRESIST = 11821 lb -in UPLIFT = 253 lb F.S. = 1.1 NOT O.K. 1.5 J Will Be Resolved By Attachment. See Page 5 -5 Summit Surgical 14-341-07 Revision Date: 10/11/2014 Seismic Forces i �([ 51 wk.( Cu*et. o oU ap = 2.5 Rp= 6 Ip = 1 z/h = 1 Component Operating Weight: 597 Ibs Fp = 0.4 ap SDS Wp [1+2 (om)] Rp l Ip Fp = 287 Ibs F p need not exceed: Fp = 1.6 Sin Ip Wp Fp = 919 Ibs F p shall not be less than: Fp = 0.3 Sos Ip Wp Fp = 172 Ibs Dimensions: x 44 in y =' 74.4 in z= 33.4_ in Curb Height 36, in Check Uplift: Mor = 15133 lb -in MRESIST = 11821 lb -in UPLIFT = 344 lb x FP Curb Height ASCE Eq. 13.3-1 ASCE Eq. 13.3-2 ASCE Eq. 13.3-3 I y I J F.S. = 0.8 <_ 1.5 NOT O.K. Will Be Resolved By Attachment. See Page Certified Drawing for 4t Unit E: ba • fib 0 CONNECTION SIZES 8 8 131N' ZSS1 NIA FIELD PONE 8 8 re re 8 see ete PT CONDENSATE DRAIN 111'-11 NPT NIS CONNECTION 2 Ill ' ISq DIA PORN SUPPLY KNOCK -OUT • eF 8 8 z RO'D NOTE 311ES IRA1.I N Nao M r r C 'ea C V tee •TIIE-IA1EPAN' FACTOR 111 ORLP N.T, A Z AN .8- � 8S WO g. ....< h. ~. 'V ^ w 8 § ■..` . 10 1.22 2r2 ME 1.•I II II!I Il}f ;l !:I1 III H C CC 0 i • 48TM500993 6 /3 S r1 Packaged Rooftop Builder Performance Summary For 4t Unit Project: Summit Surgical Prepared By: 10/09/2014 04:09PN Part Number:48TCDA05A2A3-0A0A0 ARI SEER• 13.00 Base Unit Dimensions Unit Length* 74.4 in Unit Width: 44.0 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 537 Ib Medium Static Option. 10 Ib Accessories Standard Leak Vertical EconoMi$er IV with solid-state controller. 50 Ib Total Operating Weight: . 597 Ib Unit Unit Voltage -Phase -Hertz: 208-1-60 Air Discharge' Vertical Fan Drive Type' Belt Actual Airflow: 1600 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/Ib Evaporator Leaving Air DB• 60.2 F Evaporator Leaving Air WB: 57.7 F Evaporator Leaving Air Enthalpy 24.83 BTU/Ib Gross Cooling Capacity: 47.60 MBH Gross Sensible Capacity. 34.22 MBH Compressor Power Input: 3.31 kW Coil Bypass Factor: 0.246 Heating Performance Heating Airflow: 1600 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 102.4 F Gas Input Capacity. 72.0 MBH Gas Heating Capacity: 56.00 MBH Temperature Rise: 32.4 F Supply Fan External Static Pressure- 0.75 in wg Options / Accessories Static Pressure Economizer 0.07 in wg Total External Static: 0.82 in wg Fan RPM- 1079 Fan Power 0.95 BHP NOTE: Selected IFM RPM Range: 770 -1175 Electrical Data Voltage Range: 187 - 253 Compressor #1 RLA. 21.8 Compressor #1 LRA• 117 Indoor Fan Motor Type• MED Indoor Fan Motor FLA: 4.9 Combustion Fan Motor FLA (ea)- 0.48 Packaged Rooftop Builder 1.391 !!. 4 •••,.. BTL ENGINEERING. CootJecpuil 6,Jug5ir Ga5e. VS, 1.7 TI: C.uI213 • • ? 8 .9,3e sirup 1-,1 412 zwe 5.11tafl eh CP (afesirit se-i {1,5 ePe is(pt 11 4\ lb 190)1 WataMp: Rod NE, Suite 100 Waarrywille, WA 90072=4135 Phone: :125.13111i14411 Put 12571121720,0 5-02e-is 1L P 114 tT7a6 6UfZr7 Tb C200F (4)•tart- Us5e) /(2‘..t Pr . _ 1 1 I r tz, ;5(RELd • 3L‘A 17A 1,.g 5 - 6 ) A iSurNt u r u (t- 51Yr _PA '.:1-r)d 34 et:Vs •T• Gc( 5uratti sviELLJ aT) r • • 01.• • \v5e. fs 1/21_1 0 -S t4 AIL 5 e:IflL Project: Designed By. Proicct Number. r • 5-61 Dale: Pam arcs 25 20 16 16 14 En. Edge DaI And 0.0 Spacing EU6LE,HEAD — SELF D .tNG rcr dlynDll oltochmunl to Tula uldds and lads. Nso clad tar oiiarhingg cobintln Waugh gypsum tiogrd and linulillan hoard. fact 1hlpineu — 20. t 16 and '14 gouge: HUI E HEAD For d al! itehmenl In metal elude and Joab. Nsa wed Ioi alioe cabinets Waugh' ` - - hoard ant! lnwlernin tiriaid: Natal t en- '25 find gongi. WAFER HEAD - SIBPDRILLihEG For metal. la Metal Iranitrig.raMee!Jnn wben.d ' od and other ebidibr tio»`rrgladds.ori:rised am.metal 'istids and Helot thlikness - 20,' 15. 15 iind 14 gouge. WAFER fEAD• roe maa1 to palol lmming comedians On dd411ll„ good od and other, Wade tan' WieilO' tapesd, on .meta Audi andJJpl ts; Metal thickness 'I.! '25' obi ".20 gage: NEXIEA1) - SBF DRUM Farending tieel.deeh; do : Aden; door Munn, tolhern: oeuevit to metal framing Ind' ilnietrir eonneellons; Nitc12111 lwde — .20. 16,' 16 and 11 gnat. PAN HEAD - EELF Df U1JC Fir clliehkg sled dtchi, 6odirip plain, Out ,Thames. loftier. shone! 10 liirmlil Trianing and filmetarol'eonreetlos. Metol 1blclddif 16, 16. and. 14 gouge, " No..12 (do0.205') Shear .lidlout 74 3117 151 l: J 190 11/I H No. 10 (dn0.16S) ' Shin Fu11aid 69 14 173 61 256 105 363 132 513 166 9/16' No. IL (d0D.1611; •Shair Maul 65 39 . 71 93 341 116 N/A H/A 1/2' tlo..6 (du0.139 Sheer Moil. 69 32 149 50 222 76 H/A WA N/A N/A 1/t Haler. 1. All ndueo nosid on cannecled pods hosing olminMium yleld'.iiresr,'Fy--33 Ist and a minimum Whali ilea», Fu»45 "tail. 2. When :eonnicllny riioladols al .ddferant gouge Neiman. use la di ;Noun for .1ht Miler gouge. . 3. Applied' :hear loads Toy be mutliplied by 0.75 for wind or eorlhgnlie lab par AIS1 Alai: 4. For ucrein its tension, the hood of the saran. or molar 11 piasldad, shoe" lima o mtnimoni dtamaler of 5/16 Inch. 11.R.2 Wood Screws 11.2.2..1 The reference withdrawal design value, in lb/in. of 'penetration, for a single wood screw (cu( thread or rolled thread) inserted in side grain, with the wood screw axis perpendicular to the wood fibers, shall be determined from Table 11.2B or Equation 11.2-2, within the range of specific gravities and screw diame- ters given in Table 1 1.2B. Reference withdrawal design values, W, shall be multiplied by all applicable adjust- ment factors (see Table 10,3,1) to obtain adjusted with- drawal design values, W. W a 285D G$ (11.2-2) 11.2.2,2 Wood screws shall not be loaded in with- drawal from end grain of wood, 11.2.2.3 When wood screws are loaded in with- drawal, the adjusted tensile strength of the wood screw at net (root) section shall not be exceeded (see 10.2.3). 11.2.3 Nails and Spikes 11.2.3.1 The reference withdrawal design value, in lb/in. of penetration, for a single nail or spike driven in the side grain of the main member, with the nail or spike axis perpendicular to the wood fibers, shall be determined from Table 11.2C or Equation I1.2-3, within the range of specific gravities and nail or spike diameters given in Table 11.2C. Reference withdrawal design values, W, shall be multiplied by all applicable adjustment factors (see Table 10.3.1) to obtain adjusted withdrawal design Values, W'. Wa1380Gs" D (I1.2-31 11.2,32 Nails and spikes shall not be landed in withdrawal from end grain ofwood. 11.2.4 Drift Bolts and Drift Pins Drift bolt and drifl pin connections loaded in with- drawal .shall be designed in accordance with principles of engineering mechanics. Table 11.28 Cut Thread or Rolled Thread Wood Screw Reference Withdrawal Design Values (W)1 Tabulated withdrawal design values (W) are in pounds per inch of thread penetration Into side, grain of main member. Thread length is approximately 2/3 the, total wood screw length (see.Appendix L). Specific Woad Screw Number Gravity; G 0.73 0.71 0.68 0.67 0.58 0.55 0.51 D50 0:49 0.47 0.46 0.44 0.43 0.42 D.41 0.40 0.39 038 0.37 036 0.35 0.31 6 209 198 let 176 132 119 102 98 94 87 83 76 73 69 66 63 60 57 54 51 48 38 7 229 216 199 193 144 130 112 107 103 95 91 83 79 76 72 69 65 62 59 56 53 41 .8 249 235 216 209 157 141 121 117 112 103 99 90 75 71 67 64 60 57 45 20 327 367 406 446 485 •310 347 384 421 459 284 310 '352 387 421 276 309 342 375 409 207 232 256 281 306 186 208 2231 253 275 160 179 1.98 2i7' 237 154 172 191. 209 228 147 165 183 201 219 136 152 '168 185 201 130 146 161 177 193 119 133 148 162 176 114 127 141 155 168 108 121 134 147 161 'VT 103 116 128 141 153 86 98 110 122 134 146 82 .93 105 116 127 138 78 89 99 1I0 121 131 74 84 94 1.04 114 125 70 BO 89 99 108 118 66 75 84 93 102 I 1 I O 87 1. Tabulated withdtowol design values (W) rat wvodsetew connect an shell be mut,lpl ed by e11 applicable adjustment r000r366 73 B(see Table 10.3.1). 9 268 254 233 226 169 152 131 126 121 111 107 97 93 89 85 81 77 7.3 69 65 62 48 .10• 288 272 250 243 182 163 141 135 130 119 114 105 100 12 I4 16 18 24 564 533 489 475 356 320 275 264 254 234 224 205 196 '187 178 169 161 153 145 137 130 102 8 N3.LSV J 3dA.L-13Moa AMERICO/ FOREST & PAPER ASSOCIATION 10011 Wood o *ad NEA ie 100 Woodierift WA 211012-4/36 Amos (425) 11444411 Fir (4n)mow. Detail MSTOIRTUM1100FaIN WANK RESSIMP �6�Of/Ra7lOI�PTf� OF Se) prAtl oft ' '8 Iowa "Mori lives lb GIN imps. Hoeg . (9) CAcs (16 mum) maw" D 1EW NWT • AzwQrsAainsP in MUM and' "F"'"reio," ATTACHMENT DETAIL: NONNI - • City of Tukwila Department of Community Development 3/2/2015 INNA BUCKWALTER 1916 220 ST SE STE M101 BOTHELL, WA 98021 RE: Permit No. M14-0195 SUMMIT SURGICAL 613 INDUSTRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/22/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/22/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0195 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0195 DATE: 10/13/14 PROJECT NAME: SUMMIT SURGICAL SITE ADDRESS: 613 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: c Building Division Public Works ❑ f� N/A- Ip-aa iiA Fire Prevention Structural n Planning Division Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 11/11/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 PACIFIC AIR CONTROL INC Page 1 of 2 Washington State Department of Labor & Industries PACIFIC AIR CONTROL INC Owner or tradesperson RUTTAN, GARY JAMES Principals RUTTAN, GARY JAMES, PRESIDENT CRAWFORD, LARRY C, SECRETARY (End: 10/05/2011) Doing business as PACIFIC AIR CONTROL INC WA UBI No. 601 298 907 1916 220TH ST SE STE 101 BOTHELL, WA98021-8427 206-682-6393 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PACIFAC230P8 Effective — expiration 10/28/1977— 10/01/2015 Bond TRAVELERS CAS & SURETY Bond account no. 104920215 Received by L&I 05/09/2007 Insurance PHOENIX INSURANCE COMPANY THE Policy no. 4TC07314N491 PHX09 Received by L&I 06/17/2014 $6,000.00 Effective date 05/26/2007 Expiration date Until Canceled $1,000,000.00 Effective date 07/01/2010 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601298907&LIC=PACIFAC230P8&SAW= 10/24/2014