HomeMy WebLinkAboutPermit M14-0204 - TOP POT DOUGHNUTS - SPACE HEATERSTOP POT DOUGHNUTS 401 BAKER BLVD M14-0204 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0223100085 Permit Number: M14-0204 Address: 401 BAKER BLVD Issue Date: 11/19/2014 Permit Expires On: 5/18/2015 Project Name: TOP POT DOUGHNUTS Owner: Name: PEARL ALVIN S+CAROLE R Address: 405 BAKER BLVD , SEATTLE, WA, 98188 Contact Person: Name: RICK PHILLIPS Phone: (206) 849-7453 Address: 234 FIFTH AVE S , EDMONDS, WA, 98020 Contractor: Name: WCI PLUMBING LLC Phone: (425) 774-4185 Address: 234 FIFTH AVE S , EDMONDS, WA, 98020 License No: WCIPLPL891R3 Expiration Date: 12/23/2015 Lender: Name: Address: DESCRIPTION OF WORK: SUPPLY AND INSTALL (3) REZNOR SPACE HEATERS SUSPENDED FROM ROOF STRUCTURE. SEPARATE EXHAUST VENTING FOR EACH ONE. Valuation of Work: $7,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $285.10 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2014 2012 Permit Center Authorized Signature: Date: R1NH I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: / /-79%" /y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 4: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2013 edition). 2: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 3: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 5: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***MECHANICAL PERMIT CONDITIONS*** 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 15: Manufacturers installation instructions shall be available on the job site at the time of inspection. 16: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUIC ;A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Mechanical rermit No. N't l "I-- 004"01.1 Project No. Date Application Accepted: Date Application Expires: 1t-tD-(1f 5--e (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: I-101 f3)114-R BLvD Tenant Name: Toe POt- ) OU N U-{-' PROPERTY OWNER Name: Pearl o�r'r-{wTzS i Address: 1 2 vYc. 1,,,rc v,„+v,j Ave.... 5 . City: __s,,c`t._rz State: ,,, .- Zip: Gj 6168 CONTACT PERSON — person receiving all project communication Name: R, c 9 i,' I J' iP5 Address: ;3N 51-' 1uQ 5ov4 h City: ro rN & Jd 5 State: g Zip: 1�20 Phone: a o (p J \ 149, 7 y 53 Fax: Email: . rtcKwc,ictchol-> -/,00/" King Co Assessor's Tax No.: Suite Number: New Tenant: Floor: g.] Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: . vt) c p) uyvib,,M, Ll_ c Address: 3 y Sit, A U e. so c: City: E. r �0Nds State: W4 Zip: EC) Phone: y12 S} %7Li - y/96— Fax: y 2.5) 77y- y/87 Contr Reg No.: Exp Date: WCipLPL91 R3 12- 2 3- tS Tukwila Business License No.: @9065321 Valuation of project (contractor's bid price): $ 7, COO - GO Describe the scope of work in detail: 5 vo,7/y 3 g-r 2n,c, k ..0.er'S. VeN-hs•0q r� ecick s,A„,t . ! i t9 S pP,v01 C00-C 544'vc.Pdie Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric El Gas Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment 7$004Dg}t ReZNrr vNt±keo4 i5 3 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O` Z7UTHORI AGENT: Signature: Print Name: ? r C I,C Ph - / l,p$ Mailing Address: ;. 3 L/ 644' A u P 041, //' Day Telephone: a°(ojge/9 71/63 Ed>,vd5 wA City State %$o.ZO Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAI Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 85!' 14-0209 dress:!; • 1 BAKER BLVD n: 02231000 MECHANICAL $274.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $54.83 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3490 R000.322.900.04.00 0.00 $10.97 $285.10 Date Paid: Thursday, November 06, 2014 Paid By: RICK PHILLIPS WCI PLUMBING LLC Pay Method: CREDIT CARD 016052 Printed: Thursday, November 06, 2014 8:26 AM 1 of 1 cRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit M I4-old PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 3670 Permit Inspection Request Line (206) 431-2451 Project: ,1� Type of Inspection: Address: Lib1 i; k-t ca Date Called: Special Instructions: Date Wanted: ) l Z 72 J ((L/ (a-. in..... p:m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: i�CL-1 \,A--, 1 t t (. C - . / REINSPECTION FEE R QUIRED. Prior to next inspection, fee must be paidat 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: % i Z / 7 Z I L% INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukvvila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 TV\ Project- - \ ` ry-)6N1-1 Type of inspecto,nn: - . A-d -t)..AL Address: 1-1Dt rosC4R—' Date Called: ---,• Special Instructiong A Date Wanted: q ‘ -5 - i t - P.m. Requester. N i_ l' (Q (<_ r rl '' P S Ptione N9: a, ic t , IDApproved per applicable codes. LJCorrections required prior to approval, COMMENTS: _ L'ofvt. `-` -JAbteri -1 6 Inspe br: INSPECTION FEE REQUIRED. Prior t/next inspection, fee must be p id at4300 Southcenter thvd.. Suite 100, Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA`FIRE DEPARTMENT 206-575-4407 Project: =Type-of`Ins ecti& : M -e / 5P P P ��s C4#N v--k Address: ti (30. er._ ie ( Suite #: Contact Person. Special Instructions: Phone No.: -Approved per applicable codes. Corrections required prior to approval. COMMENTS: SP Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Jl„ t 5 ,,, �c-j - Date: / / /API (/ Hrs.: 1 $1 0.00 REINSPECTION FEE REQUIRED.. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn : Company Name: Address: City: State: Zip: Word/Inspection Record. Form. Doc 3/ 14/ 14s T.F.D. Form F.P. 113 i 1 itCOS), r `� ANSI Z83.8b DESCRIPTION Reznor° V 3 Series Model UDAP gas -fired unit heat- ers are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for rdsidential application. All sizes are approved for commercial/industrial installations. Model UDAP heat- ers are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). ReznorV 3. Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily sus- pended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exte- rior of the cabinet for easy gas service connection. The preeminent new internal feature is the TCORE2 heat exchanger and single burner combustion system. Other standard features include a single -stage gas valve, multi -try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, re- siliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic in- dicator lights to identify abnormalities in control func- tions. The new V 3 Series unit heaters are designed to pro- vide all the features you expect in a Reznor heater plus improved efficiency, easier installation, and a new look - both inside and out. Form RZ-NA-C-UH Page 6 Page °ZtE CC Model UDAP Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 U.S. STANDARD FEATURES O Sizes 30-125 certified for residential heating application • Sizes 30-400 certified for commerciaUndustrial heating application • 82-83% Thermal efficient - TOP in its class! • 50-60°F Rise range • NEWTcoee2a titanium stabilized aluminized steel heat exchanger • NEW patented" TCCRE23 single burner combustion piece burner assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload prot • Transformer for 24-volt controls O Integrated circuit board with diagnostic indicator I • Multi -try direct spark ignition with 100% lockout • Fan relay (included on the circuit board) • Single -stage natural gas valve (field adjustable for elevation) O Vibration/noise isolated fan and venter motors - designed for low noise operation O 2-pt and 4-pt Suspension - standard on all sizes O Extemal terminal strip for 24-volt wiring • External gas connection • Full fan guard - engineered for safety O Improved cabinet design with less visible hardware and a NEW Reznor appearance 0 Eyste E FOR COIODCEV �COMMP�JLIANCE tion APPROVED its NOV 13 2014 peratiog i fi9,of Tukwila BUILDING DIVISION OPTIONAL FEATURES - FACTORY INSTALLED O Single -stage, propane gas valve (field adjustable for operation to 9,000 ft elevation) O Two -stage natural gas or propane gas valve - Sizes 60-400 • 409 or 316 Stainless steel heat exchangers O 208 or 230 Single phase voltage • Totally enclosed fan motor (Sizes 30-250. 115V only) O Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) ACCESSORIES - FIELD INSTALLED • Vent cap • Thermostat O Thermostat guard with locking cover O Vertical louvers - new design • Downturn nozzle kits - new design O Gas conversion kits (natural and propane) • Master/Slave controls for zoning up to six units • Ceiling suspension kit - Sizes 30-125 • Hanger kits for 1" pipe • Stepdown transformer (for 230/3 and 460/3 supply voltage) • Manual shutoff valves RECEIVED CITY OF TUKWILA NOV 0 6 2014 PERMIT CENTER I'*020H U.S. Patent No. 6.889,686 Page of Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS P and Q - Hanger Dimensions for 4-pt Suspension NI 3/8"-1 o Female Thread - all suspension points R - Hanger Dimension for 2-pt Suspension IR Thermostat Connection (30-125 Vertical; 150-400 Horizontal) Line Voltage Inlet (connects at circuit board) y Vent Connection (see Technical Data for size) Combustion Air Inlet K External 4 -- H ---' Gas Connection 0 RIGHT SIDE VIEW (Access Panel) Form RZ-NA-C-UH Page 8 Page of Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS (cont'd) MODEL UDAP DIMENSIONS (± 1/16" Size A B C D E F G H J K M N P Q R 30,45 12-1/8 26-5/8 10 13-13/16 26 21-9/16 5-3/16 6-1/2 2-11/16 3-7/8 17-3/8 11/16 4-5/16 13 9-9/16 6 15-1/8 26-5/8 13 13-13/16 27 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 75 15-1/8 26-5/8 13 13-13/16 27-5/8 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 100 23-1/8 26-5/8 21 13-13/16 28-5/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 125 23-1/8 26-5/8 21 13-13/16 29-3/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 150, 175, 200 20-1/8 38-3/16 16 23 42 35-3/8 8-1/2 8-1/4 5-7/16 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 16-3/8 225, 250 26-1/8 38-3/16 22 23 42 35-3/8 13-1/16 8-13/16 9 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 15-5/8 300, 350, 400 34-1/8 41 30 23 42 35-3/8 17-1/16 9 11-13/16 7-5/16 27-11/16 1-3/8 8-3/16 22-3/16 16-3/16 MODEL UDAP DIMENSIONS (±2mm Size A B C D E F G H J K M N P Q R 30,45 308 676 254 351 660 548 132 165 68 98 441 17 110 330 243 60 384 676 330 351 686 548 200 165 140 98 441 17 110 330 267 75 384 676 330 351 702 548 200 165 140 98 441 17 110 330 267 100 587 676 533 351 727 548 368 165 222 98 441 17 110 330 267 125 587 676 533 351 746 548 368 165 222 98 441 17 110 330 267 150, 175, 200 511 970 406 584 1067 899 216 210 138 165 652 35 208 564 416 225' 250 664 970 559 584 1067 899 332 224 229 165 652 35 208 564 397 300, 350, 400 867 1041 762 584 1067 899 433 229 300 186 703 35 208 564 411 CLEARANCES Size Top Flue Connector Access Panel Non -Access Side Bottom* Rear inches mrn inches nrn inches rim inches mm inches m n inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 uspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. Form RZ-NA-C-UH Page 9 Page of MODEL UDAP TECHNICAL DATA- Sizes 30 - 125 Size 30 45 60 75 100 125 Input Heating Capacity BTUH 30,000 45,000 60,000 7 105,000 120,000 kw/h 8.8 13.2 17.6 22.0 30.8 35.2 Thermal Efficiency(%) 82 83 83 83 83 83 Output Heating CapacityA BTUH 24,600 37,350 49,800 62,250 87,150 99,600 kw/h 7.2 11.0 14.6 18.3 25.6 29.2 Gas Connection (inches) a Natural 1/2 1/2 1/2 1/2 1/2 1/2 Propane 1/2 1/2 1/2 1/2 1/2 1/2 Vent Connection Size c (inches diameter) 4 4 4 4 4 4 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 Maximum Over Current Protection (115V)° 15 15 15 15 15 15 Normal Power Consumption (watts) 109 155 155 217 276 354 Discharge Air Temperature Rise (°F) 50 55 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 M3/minute 12.9 17.8 21.8 27.5 36.7 45.9 Discharge Air Opening Area ft2 0.96 0.96 1.25 1.25 2.01 2.01 tv12 0.09 0.09 0.12 0.12 0.19 0.19 Output VelocityFPM 475 656 616 770 668 763 M/minute 145 200 188 238 196 245 Fan Motor HP e Open 0.02 0.03 0.03 0.06 1/30 1/20 Endosed N.A. N.A NA N.A 1/4 1/4 Fan Motor RPM 1550 1550 1550 1550 1050 1050 Fan Diameter(inches) 10 10 12 12 16 16 Sound Level dba @ 15 ft 40 40 40 49 54 55 Approximate Net Weight Ibs 54 59 67 72 96 101 kg 24 27 30 33 44 46 Approximate Ship Weight Ibs 61 66 74 79 118 123 kg 27 30 33 36 54 56 MODEL UDAP TECHNICAL DATA Sizes 150 - 400 A CSA rating for altitudes to 2000 ft. °Size shown is for gas connection to a single stage gas valve, not supply line size. °Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I-V-PV. If vent diameter is dif- ferent from vent con- nection, reducer/en- largers will be field -re- quired. °MODP = 2.25 x (larg- est motor FLA) + smallest motor FLA. Answer is rounded to the nearest commer- cially available circuit breaker. E All other in- formation in this table is based on a heater equipped with a stan- dard 115 volt open fan motor. Size 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency(%) 83 83 83 83 83 83 83 83 Output Heating CapacityA BTUH 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 kw/h 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection (inches) s Natural 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size c (inches diameter) 5 5 5 5 5 6 6 6 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection (115V) ° 15 15 15 15 15 20 20 20 Normal Power Consumption (watts) 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise (°F) 60 60 60 60 60 60 60 60 Air Volume CFM 1921 2242 2562 2882 3202 3843 4483 5123 Iot3/minute 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening Area ft2 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 tvtz 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 752 877 1003 820 911 802 936 1069 M/minute 229 267 306 250 278 244 285 326 Fan Motor HP e Open 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Endosed 1/4 1/4 1/4 1 1/4 1/4 1/2 1/2 1/2 Fan MotorRPtv1 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter(inches) 18 18 18 20 20 24 24 24 Sound Level dba @ 15 ft 51 52 53 56 56 59 61 62 Approximate Net Weight Ibs 172 187 187 203 215 269 294 306 kg 78 85 85 92 98 122 133 139 Approximate Ship Weight Ibs 204 219 219 245 257 321 346 358 kg 93 100 100 111 117 146 157 163 Form RZ-NA-C-UH Page 7 PLAN REVIEWSUTING SLIP PERMIT NUMBER: M14-0204 PROJECT NAME: TOP POT DOUGHNUTS SITE ADDRESS: 401 BAKER BLVD X Original Plan Submittal Response to Correction Letter # DATE: 11/06/14 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C `III Building Division Public Works ire Prevention Structural n Planning Division Permit Coordinator et PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/04/14 Approved Approved with Conditions Corrections Required ❑ Denied (ie: Zoning Issues) (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WCI PLUMBING LLC Page 1 of 2 0 Washington State Department of Labor & Industries WCI PLUMBING LLC Owner or tradesperson LESSARD, MATTHEW JAMES Principals LESSARD, MATTHEW JAMES, PARTNER/MEMBER HOLOBAUGH, TRENT LEE, PARTNER/MEMBER CARTER, PAUL FLYNN, PARTNER/MEMBER LESSARD, MATTHEW JAMES, AGENT Doing business as WCI PLUMBING LLC WA UBI No. 603 166 416 234 5TH AVE SOUTH EDMONDS, WA98020 425-774-4185 SNOHOMISH County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. WCIPLPL891 R3 Effective — expiration 12/23/2011-12/23/2015 Bond Travelers Cas and Surety Co of America Bond account no. 105693076 Received by L&I 12/23/2011 Insurance Phoenix Insurance Company, The Policy no. DTC0526D7304PHX14 $6, 000.00 Effective date 12/20/2011 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603166416&LIC=WCIPLPL891R3&SAW= 11/19/2014