Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M14-0210 - GRILL CITY - KITCHEN HOOD, FAN, AIR BALANCE AND DUCTWORK
GRILL CITY 1368 SOUTHCENTER MAIL 140 M14-0210 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470090 Permit Number: 1368 SOUTHCENTER MALL 140 Project Name: GRILL CITY Issue Date: Permit Expires On: M14-0210 10/30/2015 4/27/2016 Owner: Name: Address: Contact Person: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 WILLIAM MILLHOLLIN 1026 SW 151 ST, BURIEN, WA, 98166 Contractor: Name: LAKE WASHINGTON CONST SVCS INC Address: 5511 NE 70TH ST, SEATTLE, WA, 98115 License No: LAKEWWC866LZ Lender: Name: Address: Phone: (206) 601-7043 Phone: (206) 523-4869 Expiration Date: 6/9/2016 DESCRIPTION OF WORK: KITCHEN HOOD, EXHAUST FAN, AIR BALANCE AND ASSOCIATED DUCTING FOR NEW FOOD COURT TYPE RESTAURANT AREA WITHIN SEAFOOD CITY Valuation of Work: $10,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $324.28 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: OA& ft/ ihisitil Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: //� — Date: Print Name r R✓h GC�� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 5: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 4: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 7: Local U.L. central station supervision is required. (City Ordinance #2437) 8: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 6: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 15: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 16: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 17: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 18: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 19: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 20: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 21: ***MECHANICAL PERMIT CONDITIONS*** 22: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 23: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0609 PIPE/DUCT INSULATION 0 1800 MECHANICAL FINAL 0 0701 ROUGH -IN MECHANICAL CITY OF TUKI A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M,1 H t%_2[ Project No. Date Application Accepted: 1( )-S— ( 4 Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Describe the scope o w k in detail: WIA if/ea: t Q (� '� J 610 Site Address: t�� (Jt /J� Q./TnC e Matt ( Suite Number: I 0 Floor: Tenant Name: rgtn V \ `i PROPERTY OWNER Name: � p 7 4l 'zt � l' p i, �r Address:1.3 / I'�lti6 City: ra f j f-(0,... State: / (/1_. Zip:4/6/6ff CONTACT PERSON — person receiving all project communication Name: !r 1 / / �i{ l f 1 o t �� ��ll� Address: IQZ4 ;iv) ( l g f - City: arl eA State: ' Zip: �f (UO x: Phone: j,r60 f y'2 Fax: ' l jof/ �,��7/ �—' Email: l j Vii. ,t/ v/ il11 f erM fe King Co Assessor's Tax No.: New Tenant: 14 Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ c :eh GJ • eet -type fes at4/ G Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement Other: H:' pplications\Porms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent I Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm l Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct I Incinerator — domestic Incinerator — comm/industrial Unit Type I Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NE OR AUTHORIZED AGENT: Signature: Print Name: A. 1 {OLM Mailing Address: /0Z6 7 //7- Day Telephone: Rtuiel City Date: `7Z0/1( 96 60/ 461(S fibf- State Zip H:'Applications\Forms-Applications On Line\2011 ApplicationsWlechanical Permit Application Revised 8.9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,235.70 D14-0365 Address: 1368 SOUTHCENTER MALL 140 Apn: 9202470090 $715.25 DEVELOPMENT $681.40 PERMIT FEE R000.322.100.00.00 0.00 $676.90 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $33.85 TECHNOLOGY FEE R000.322.900.04.00 0.00 $33.85 M14-0210 Address: 1368 SOUTHCENTER MALL 140 Apn: 9202470090 $261.92 MECHANICAL $249.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $216.95 TECHNOLOGY FEE $12.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $12.47 PG14-0179 Address: 1368 SOUTHCENTER MALL 140 Apn: 9202470090 $258.53 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 PLUMBING $125.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $93.00 TECHNOLOGY FEE $11.15 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6544 R000.322.900.04.00 0.00 $11.15 $1,235.70 Date Paid: Friday, October 30, 2015 Paid By: KERI YANG Pay Method: CREDIT CARD 01151C Printed: Friday, October 30, 2015 11:52 AM 1 of 1 SYSTEMS DESCRIPTIONS PermitTRAK . Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID ,134.06 D14-0365 Address: 1368 SOUTHCENTER MALL 140 Apn9202470090 �439.99 DEVELOPMENT $439.99 PLAN CHECK FEE R000.345.830.00.00 0.00 $439.99 D14-0366 Address: 1368 SOUTHCENTER MALL 110 Apn:9202470090 439.99 DEVELOPMENT $439.99 PLAN CHECK FEE R000.345.830.00.00 0.00 $439.99 EL14-1149 Address: 1368 SOUTHCENTER MALL 110 pn: 9202470090 35. ELECTRICAL $35.05 PLAN CHECK FEE R000.345.832.00.00 0.00 $35.05 EL14-1150 Address: ''1368 SOUTHCENTER MALL" n:9202470090. 35.05 ELECTRICAL $35.05 PLAN CHECK FEE R000.345.832.00.00 0.00 $35.05 M14-0209 Address: 1368 SOUTHCENTER MALL 110 n: 9202470090 62.36 MECHANICAL $62.36 PLAN CHECK FEE R000.322.102.00.00 0.00 $62.36 M14-0210 Address: 1368 SOUTHCENTER MALL 140 na9202470090 62.36 MECHANICAL $62.36 PLAN CHECK FEE R000.322.102.00.00 0.00 $62.36 PG14-0178 Address: 1368 SOUTHCENTER MALL 110 Apn: 9202470090 27.88 PLUMBING $27.88 PLAN CHECK FEE R000.322.103.00.00 0.00 $27.88 PG14-0179 Address: 1368 SOUTHCENTER MALL 140 Apn: 9202470090 $31.38 PLUMBING $31.38 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R3643 R000.322.103.00.00 0.00 $31.38 $1,134.06 Date Paid: Tuesday, November 25, 2014 Paid By: GARY WANG & ASSOCIATES INC Pay Method: CHECK 1150 Printed: Tuesday, November 25, 2014 12:46 PM 1 of 1 CRWYSTEMS re INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:, &r-t (( c( .1- f Type of Inspection: e jtec FF Ks Ad ress: f 3 6 50 v.�f(LC' -. MJt f l ate Called: l if 4 Special Instructions: 14A Date Wanted: Z "10•--1,4 a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. M M ENTS: Inspector: Date:2 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProjectGrit/ ri , ( ()L LC Type ofspecti Tir 4 ,..4 4telAddrreess: 7 6� OL.[ii/ detrd C.4 % / O Special Instructions: / i3„ �C/ Date Wanted: �/� a. m^ p.m. Requestery. O Phone No: C1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: G e diet 1 c/ .¢ //ek Lr� Inspector: Dater e / ' REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. T c. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd... #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:�^ (-MO t L L v �T : Type of Ins•ectionl { ilk, _ 1 G /l / e Address: /f� Dat . .a 9 Date Wanted: //7)ifea.m Special Instructions: rx Requester: Phone No: nApproved per applicable codes. Corrections required prior to approval. COMMENTS: 9r " 0 / it I7o wr•�- r) LATi- fluy 5 Li) /C/ / -�`est-/cm, AU'AI arse e. Ad 7-5e4e4A• is c'to c/- well j,4 pct,,/,i(L) i 6,71) 1--. rfl-, -C . eft., F7fle wrIO - Inspector: ✓CA-fr;a9-- Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD MN (Vf0 Retain a copy with permit 9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: G 3/ Oily Type oszpecon e/dAddress. e /3L .9ciI�Cejti% ol a tan /lL, Special Instructions: / .7Gv00/ Date Wanted: S / a m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 15"/ 7er rrezteir,y0 (Z:fre_A-sc__Die nspector: Cwr4e/Ar Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD 1170 l0 Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project r/, Z �+ C (d/ Vr* Type of 1SX roc ,—� 4 /C0 Address: 1'3f S' Siff' ce r /V Da -Called: Special Instructions: Date Wanted: // . a.m: Requester. C er Phon 77i G*47.(3 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: C,/fx2ce=3. /14/ Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION MN / 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro ect: J `tea r►' a, Cf/y Type of Inspection: C01 Gre.* �Clcic_ , rsi ids Addd s:� q .&tii/ lie ld� //`Date I,3ac� led: Spec! Instructions: Instructions:/ Wanted: ,a.m ig/36// 1. Requeste 14, Phone No: 9 V—•33qi— C69S t Approved per applicable codes. Corrections required prior to approval. COMMENTS: Per// iL4I,,&)d?-/ Ageg Inspector: '7.7.-/A4_6-4,71dt Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calf to schedule reinspectian. INSPECTION RECORD CJ Retain a copy with permit INSPECTION NO. PERMIT NO. frl I -02/) CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 9818 (20W 4.131-36791 Permit Inspection Request Line (206) 438-9350 ou Project , // Type of Ins/peCt on•' Address: ,,�� „--,7 Dat alle Special Instructions: cezt, Date Wanted: C. J''' / p.m. Rel he�s7ter: p�gQ �d�` 5"6 ' 6 U 7 P2.h//o/n e No: ��/// f `J�//r (/�/"� { M- 37-33 4 7, ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: C-711e-C (.5.A114. Inspector: C;/%4.41- Date: �7 5 REINSPECT1ON FEE REQUIRED. Prior to next insper_ti n, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 C- 0/9 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /ti - /4 _ ;1045 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �— ' ' ) 1 ca Type of Inspection: �4'c- J 5/2/-c,,,AL.- Address: i 7 t L Suite #: ; el r'V Contact Person: Special Instructions: { Phone No.: _Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 .-C, ki to i c)k- ro. , ', .� r S ,,J C -0 �! Pam--tr�r-�2 , G' " '• l 7) - 0e f i r - ii, S 1 VI-rC k - o IL E% !, A.- t Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: // ,, -<-; i Date: ? 1,�, fA Hrs.: /' t $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila Department of Community Development October 5, 2015 WILLIAM MILLHOLLIN 1026 SW 151ST ST BURIEN, WA 98166 RE: Application No. M14-0210 GRILL CITY 1368 SOUTHCENTER MALL 140 Dear WILLIAM MILLHOLLIN: Jim Haggerton, Mayor Jack Pace, Director Permit application M14-0210 for the work proposed at GRILL CITY (1368 SOUTHCENTER MALL 140) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 11/25/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: M14-0210 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director May 18, 2015 William Millhollin 1026 SW 151' St Burien, WA 98166 RE: Request for Application Extension Grill City —1368 Southcenter Mall Suite 140 Dear Mr. Millhollin, This letter is in response to your written request for an extension to Application Number M14-0210. The Building Official has reviewed your letter and considered your request to extend the above referenced application. It has been determined that the City of Tukwila Building Division will be extending your permit application an additional 180 days, through November 25, 2015. If you should have any questions, please contact our office at (206) 431-3670 extension 1. Sincerely, Bill Rambo Permit Technician File: Permit M14-0210 W:V'ermit Center\Extension Letters\Applications\2014\M14-0210 App Extension Letter #1.docx !, znn At tnn . T,.7 ,.:; . 117 L. . ._ no t o o n> _._ _ ,1n4 A 9 1 7L^7n - ')1 Bill Rambo From: Sent: To: Cc: Subject: Bill Juli Brower <juli@lwcsinc.com> Tuesday, May 12, 2015 1:15 PM Bill Rambo Elmer Saunders; Jereme Brower; John Anggala Re: Permit Extension for Grill City and Crispy Town Per our conversation yesterday morning, GRILL CITY- D14-0365 - $715.25 EL14-1150 - $147.21 (electrician has to pick M14-0210 - $285.53 PG14-0179 - $285.53 CRISPY TOWN — D14-0366 - $715.25 EL14-1149 - $147.21 (electrician has to pick M14-0209 - $285.53 PG14-0178 - $285.53 up) up) I am requesting to extend the following pedinits for 6 months: Request for Extension # Current Expiration Date: 5"-'(6--- Extension Request: IApproved for days 0 Denied (provide explanation) According to Marti, there was an over the counter electrical for Grill City $104.37. Please extend this permit 6 months as well. I am also requesting for my contact information to be added to the contact list. Thanks Again! Juli Brower Office Manager Lake Washington Construction Services, Inc. 5511 NE 70th St Seattle, WA 98115 206.455.5458 On Mon, May 11, 2015 at 9:13 AM, Juli Brower <juli@lwcsinc.com> wrote: Bill Signature/Initials ( hat was issued and it was E•„-1' i re> 001— i3c""1- (rf--- ke,44,6 RECEIVED CITY OF TUKWILA MAY 1 2 2015 PERMIT CENTER Per our conversation this morning, I am requesting to extend the following permits for 6 months: GRILL CITY- D14-0365 - $715.25 EL14-1150 - $147.21 (electrician has to pick up) M14-0210 - $285.53 PG14-0179 - $285.53 1 City of Tukwila Department of Community Development April 8, 2015 WILLIAM MILLHOLLIN 1026 SW 151 ST BURIEN, WA 98166 RE: Application No. M14-0210 GRILL CITY 1368 SOUTHCENTER MALL 140 Dear WILLIAM MILLHOLLIN: Jim Haggerton, Mayor Jack Pace, Director Permit application M14-0210 for the work proposed at GRILL CITY (1368 SOUTHCENTER MALL 140) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 05/25/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0210 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1 PLUMPGROUP ARCHITECTURE & ENGINEERING December 26, 2014 City of Tukwila Department of Community Development 6300 Southcenter Blvd. Suite #100 Tukwila, WA 98188 Re: Correction Letter #1 Mechanical Permit Application No. M14-0210 Grill City 1368 Southcenter Mall Ste 140 Mr. Rambo, The following are the responses to the Mechanical plan check review comments: Mechanical Plan Review Comments 1. Provide engineered details for roof and ceiling penetrations.... Response: Refer to added drawing No. M-3.1 Details 1 and 2. RECEIVED CITY OF TUKWILA JAN 0 6 2015 PERMIT CENTER 2. Provide horizontal length with total length dimensions... Response: Revised drawing No. M-1.0 to include lengths of Type I ductwork. Refer to Floor Plan and Keynote No. 10. Duct sizes are shown on the floor plan. Refer to drawing M-1.0 Keynote No. 10 and added drawing No. M-3.1 Detail 1 Note No. 2 for slope of grease ducts. Refer to revised Drawing No. M-1.0 note No. 10 and drawing No. M-3.1 Detail 1 Note 4 for grease duct cleanouts. 3. Where duct access panels are located... Response: Refer to new drawing No. M-3.1 Detail 1 Note 4 for "ACCESS PANEL. DO NOT OBSTRUCT." sign. 4. There is other mechanical equipment indicted on the roof... Response: Revised drawing No. M-2.0 Grill City Roof Plan to identify other existing mechanical equipment (not in contract). Provided dimensions at exhaust fan that indicates a minimum distance of 10'-0" between fan and outside air intakes and 5'-0" between fan and edge of building in compliance with 2012 IMC Section 506.3.13.3. Please do not hesitate to contact our office if you have additional questions or concerns. Regards, David L. Grijalva Designer PLUMPGROUP / Architecture & Engineering 914 E Katella Ave Anaheim, California 92805 P:714.385.1835 www.plumpgroup.com City of Tukwila Department of Community Development December 11, 2014 WILLIAM MILLHOLLIN 1026 SW 151 ST BURIEN, WA 98166 RE: Correction Letter # 1 MECHANICAL Permit Application Number M14-0210 GRILL CITY - 1368 SOUTHCENTER MALL STE 140 Dear WILLIAM MILLHOLLIN, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. Provide engineered details for roof and ceiling penetrations for new mechanical ducts. Specify duct clearances for new Type I ducts and specify type of approved duct wrap insulation. 2. Provide horizontal length with total length dimensions for new Type I ducts. Show ducts sized for the distance and include the specifications for minimum slope of duct relative to the horizontal length of grease ducts installed. Provide an analysis of that area to indicate the duct installation shall not be affected by or affect other building wall penetrations, ceiling elements or equipment in the ceilings to provide proper travel and slope of the new Type I ducts. Include specifications with details for the cleanout ports and show spaced a minimum of 20 feet apart. (IMC 506.3.6, 506.3.7, 506.3.8 & 506.3.9) 3. Where duct access panels are located, specify an approved sign shall be placed on access opening panels with wording as follows: "ACCESS PANEL. DO NOT OBSTRUCT." (IMC 506.3.12) 4. There is other mechanical equipment indicated on the roof shown in gray lines and the exhaust outlet appears to be located less than 10 feet of the parapets. Identify on the plan what the other mechanical equipment is. Show exhaust outlets shall be located not less than 10 feet horizontally from parts of the same or contiguous buildings...Exhaust outlets shall be located not less than 10 feet horizontally from or not less than 3 feet above air intake openings into any building. Exhaust outlets shall terminate not less than 5 feet horizontally from parts of the same or contiguous building, an adjacent building, adjacent property line and air intake openings into a building where air from the "exhaust outlet discharges away" from such locations. (IMC 506.3.13.3) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. Kann c,,,,*ti,.nwei*n,- u,,,,Jn,,,,,-,4 Inn . T„/,,,,;i u� ��: t O.Q 122 . lnA._4 1_ a/7n 1 aKA-c In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M14-0210 f ?fl l Cn,,thr'orltor Pnulounrri ,Quito }p1nn • Trllrwiln Wnchinotm" QR1RR • Phnwo -2f7n • Pnv 7nx_A 1-2FI PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0210 PROJECT NAME: GRILL CITY DATE: 01/06/15 SITE ADDRESS: 1368 SOUTHCENTER MALL, STE 140 Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C Building Division ir Public Works Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/08/15 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved DUE DATE: 02/05/15 Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I2/18/2013 PLAN -1RIMINTING SLIP PERMIT NUMBER: M14-0210 PROJECT NAME: GRILL CITY DATE: 11/25/14 SITE ADDRESS: 1368 SOUTHCENTER MALL - SUITE 140 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,4-� Coy V Building Division II Public Works Aux, 041'1 Fire Prevention Structural Planning Division Permit Coordinator /11 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 12/02/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/30/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: t) k 1 1 Departments issued corrections: Bldg-- Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-367i Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 01/06/2014 Plan ChecWPermit Number: M14-0210 Response to .Incomplete Letter # Response to Correction Letter # 1 Revision # after Permit is Isstied Revision reqtiested by a City Building Inspector or Plans Examiner Project Name: Grill City Project Address: 1368 Southcenter Mall , Suite #140 Contact Person: William Millhollin Phone Number: (206) 601-7043 Summary of Revision: Please see revised M pages for: 1) Engineered details for roof and ceiling perietrations 2) Notes and dimensions for Type I ducts 3) Notes and location of duct access panels 4) Updated location of exhaust outlets Sheet Number(s): MO.1 /M0.2/M 1 /M 1.1 /M2/M3/M3.1 /M4 "Cloud" or highlight all areas of revision including date of revision -r Receive) LA JAN 06 2015 PERMIT CENTER Received at the City of Tukwila Permit Center by: Ilk Entered in Permits Plus on H:\Applications\Forms-Applications 0n Line\2010 Applications\7-2010 - Revision Submittal.doc Revised: May 2011 LAKE WASHINGTON CONST S"''S INC Search L&I Page 1 of 2 SEARCH Hoare Inicio en Espanol Contact A-Z Index Help My Secure I 1. Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of k,% Labor & Industries LAKE WASHINGTON CONST SVCS INC Owner or tradesperson Principals SAUNDERS, ELMER CLAUDE, PRESIDENT Doing business as LAKE WASHINGTON CONST SVCS INC WA UBI No. 603 396 286 5511 NE 70TH ST SEATTLE, WA98115 206-523-4869 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. LAKEWWC866LZ Effective — expiration 06/09/2014— 06/09/2016 Bond ................. American Contractors Indem CO Bond account no. 100214368 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 06/09/2014 01/24/2013 Expiration date Until Canceled Insurance ......... .................. Western World Ins Co Policy no. NPP8267823 $1,000,000.00 Received by L&I Effective date 08/26/2015 08/26/2015 Expiration date 08/26/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations .................... _......... _........... No license violations during the previous 6 year period. 1 i https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603396286&LIC=LAKEWWC866LZ&SAW= 10/30/2015 ABBREVIATIONS LEGEND GENERAL NOTES ABBREV DESCRIPTION ABBREV DESCRIPTION SYMBOL ABBREV DESCRIPTION A ABV AC ACDR ACFM ACPL AFF AFG AFU AFUE AH ALT APPROX ARCH AUTO AUX B BEL BHP BKGND BLDG BOT C C/C CA CAP CC CD CENT CER CFM CHR CHS CKT CLG CONC COND CONN CONT COP CR CS D DB DIA DIFF DISCH DL DN DTR DWG DX E EA EAT EER EER EFF ELEC ELEV EMS ENT EQUIP ER ESP_ EWT EXH EXIST OR (X) EF F °F F&B FCV FC FDP FIN FD FLA FLEX FLR FS FP FPM FT FR G GAL GALV GND GPM H HB HD ORIZ HP HR HS HVAC HZ IN INSUL INV IPLV ABOVE AIR CONDITIONING ACCESS DOOR ACTUAL CUBIC FEET PER MINUTE ACCESS PLATE/PANEL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR FILTER UNIT ANNUAL FUEL UTILIZATION EFFICIENCY AIR HANDLING UNIT ALTERNATE APPROXIMATE, APPROXIMATELY ARCHITECT(URAL) AUTOMATIC AUXILIARY BELOW BRAKE HORSEPOWER BACKGROUND BUILDING BOTTOM CENTER TO CENTER COMBUSTION AIR CAPACITY COOLING COIL CEILING DIFFUSER CENTRIFUGAL CEILING EXHAUST REGISTER CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CIRCUIT CEILING CONCRETE CONDENSATE; CONDENSING CONNECT; CONNECTION• CONTINUE; CONTINUOUS; CONTINUATION COEFFICIENT OF PERFORMANCE CONDENSER WATER RETURN CONDENSER WATER SUPPLY DRY BULB; TEMPERATURE DIAMETER DIFFUSE; DIFFUSER DISCHARGE DOOR LOUVER DOWN DOWN THRU ROOF DRAWING DIRECT EXPANSION EACH; EXHAUST AIR ENTERING AIR TEMPERATURE ELECTRONIC EQUIPMENT ROOM ENERGY EFFICIENCY RATIO EFFICIENCY ELECTRIC; ELECTRICAL ELEVATION ENERGY MANAGEMENT SYSTEM ENTERING; ENTRANCE EQUIPMENT EXHAUST REGISTER EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXISTING EXHAUST FAN DEGREE FAHRENHEIT FACE AND BYPASS FLOW CONTROL VALVE FAN COIL UNIT FIRE DAMPER FINISH(ED) FLOOR DRAIN FULL LOAD AMPS FLEXIBLE FLOOR SUPPLY FAN FIRE PROTECTION FEET PER MINUTE FEET FROM GALLON GALVANIZE; GALVANIZED GROUND GALLONS PER MINUTE HOSE BIBB HEATING COIL HEADER HORIZONTAL HORSEPOWER HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY HEATING, VENTILATING AND AIR CONDITIONING HERTZ INCH INSULATION INVERT ELEVATION INTEGRATED PART LOAD VALUE K L M N 0 P KW LAT LBS LD LIN LR LRA LVR LWT MAU MAX MCA MCC MFR MH MIN MISC MPG MTD MVD N/A NC NEG NO NPSH NTS OBD OD OF CI OF OI OSA PD PH PL PNEU POC PPM PRESS PRF PRV PSIG PVC Q QTY R S T U R RA RED RHF RLA RPBP RPM RR SA SCFM SEER SOV SP SQ FT SR SS STD SW TA TBD TEMP TG TYP UC UCP UG UTR v V VB VEL VTR W W/ W/O WB WC WT KILOWATT LEAVING AIR TEMP POUNDS LINEAR DIFFUSER LINEAR LINEAR REGISTER LOCKED ROTOR AMPS LOUVER LEAVING WATER TEMP MAKE-UP AIR UNIT MAXIMUM MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MANUFACTUR(ED) (ER) MANHOLE MINIMUM MISCELLANEOUS MEDIUM PRESSURE GAS MOUNTED OR MOUNTING MANUAL VOLUME DAMPER NOT APPLICABLE NORMALLY CLOSED NEGATIVE NORMALLY OPEN NET POSITIVE SUCTION HEAD NOT TO SCALE OPPOSED BLADE DAMPER OUTSIDE DIAMETER OUTSIDE AIR OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED PRESSURE DROP PHASE PLATE PNEUMATIC POINT OF CONNECTION PARTS PER MILLION PRESSURE PREFILTER PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH GAGE POLY -VINYL CHLORIDE QUANTITY RELOCATE RETURN AIR REDUCER REFERENCE RELATIVE HUMIDITY (PERCENT) RATED LOAD AMPS REDUCED PRESSURE BACKFLOW PREVENTOR REVOLUTIONS PER MINUTE RETURN REGISTER SUPPLY AIR STANDARD CUBIC FEET PER MINUTE SHUT OFF VALVE STATIC PRESSURE SQUARE FOOT/FEET SUPPLY REGISTER STAINLESS STEEL SMISIOMIDENERGY EFFICIENCY RATIO SWITCH TRANSFER AIR TO BE DETERMINED TEMPERATURE TRANSFER GRILLE TYPICAL DOOR UNDERCUT UNIT CONTROL PANEL UNDERGROUND UP THRU ROOF VOLTS; VOLTAGE VACUUM BREAKER VELOCITY VENT THROUGH ROOF WITH WITHOUT WET BULB TEMPERATURE WATER COLUMN WEIGHT PLAN CHECK NOTES APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION & SERVICE WITHOUT REMOVING PERMANENT CONSTRUCTION. ALL MECHANICAL EQUIPMENT SHALL BE LISTED AND LABELED BY AN APPROVED TESTING AGENCY. IF NOT PROVIDE COMPLETE INFORMATION ON THE EQUIPMENT. TESTING BY AN APPROVED TESTING LABORATORY MAY BE REQUIRED BEFORE FINAL APPROVAL IS GRANTED. X 1 1 R-- DL 0 0 M EFE13 -EP -19-A -Eak C CcJi REVISIONS• No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE; Revisions will require a new plan submittltl and may include additional plan review fees. ACD FD SFD BDD FILE COPY Permit No. 1 ono Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field y conditions is acknowledged: By: Date: /0//o /20cr City of Tukwila BUILDING DIVISION SUPPLY AIR DUCT (UP/TOWARD) RETURN AIR DUCT (UP/TOWARD) EXHAUST AIR DUCT (UP/TOWARD) OUTSIDE AIR DUCT (UP/TOWARD) SUPPLY AIR DUCT (DOWN/AWAY) RETURN AIR DUCT (DOWN/AWAY) EXHAUST AIR DUCT (DOWN/AWAY) OUTSIDE AIR DUCT (DOWN/AWAY) ELBOW WITH TURNING VANES (AIRFOIL TYPE) DUCT WITH INTERIOR LINING (SIZE INDICATED IS INSIDE CLEAR) DUCT RISE WITH RESPECT TO AIR FLOW DUCT DRO' WITH RESPECT TO AIR FLOW FLEXIBLE CONNECTION ACCESS DOOR (AD) DOOR UNDERCUT DOOR, LOWER SUPPLY AIR CEILING DIFFUSER WITH DIRECTION OF THROWS AS INDICATED ON PLANS RETURN REGISTER OR GRILLE EXHAUST REGISTER OR GRILLE FLEXIBLE DUCT (SINGLE LINE) FLEXIBLE DUCT (DOUBLE LINE) AUTOMATIC CONTROL DAMPER MANUAL VOLUME DAMPER W/ REMOTE OPERATOR FIRE DAMPER SMOKE FIRE DAMPER BACK DRAFT DAMPER C/C=COOLING COIL H/C=HOT WATER HEATING COIL E/H=ELECTRIC DUCT HEATER FAN OR BLOWER PNEUMATIC PIPING ELECTRICALWIRING CONTROL AIR MAIN MANUAL SWITCH ROOM THERMOSTAT TEMPERATURE SENSOR SMOKE DETECTOR ITEM FURNISHED AND INSTALLED UNDER DIVISION 16 POINT OF CONNECTION DIAMETER CENTERLINE SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical grEtectricat Numbing Giseas Piping C_�y of Tukwila DIVISION 1. MECHANICAL CONTRACTOR SHALL EXAMINE ALL OTHER SPECIFICATIONS, DRAWINGS AND ALL FEATURES OF BUILDING CONSTRUCTION WHICH MAY AFFECT HIS WORK AND SHALL BE GOVERNED BY THESE AND OTHER SPECIFICATIONS, INCLUDING THE GENERAL CONDITIONS AND PARTICULAR INSTRUCTIONS TO ALL BIDDERS AND SUPPLIERS. 2. ALL WORK SHALL BE EXECUTED AND INSPECTED IN STRICT ACCORDANCE WITH ALL LOCAL CODES AND/OR STATE CODES, LAWS, ORDINANCES, RULES AND REGULATIONS APPLICABLE TO THIS PARTICULAR CLASS OF WORK, AND EACH MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL APPLICABLE SERVICE CHARGES, FEES, PERMITS, TAXES, AND OTHER SIMILAR COSTS IN CONNECTION THEREWITH. 3. PRIOR TO FABRICATION OF DUCTWORK, MECHANICAL CONTRACTOR SHALL EXAMINE AND VERIFY ALL CONDITIONS ABOVE AND BELOW THE CEILING WHICH MAY INTERFERE WITH THE DUCT SYSTEM AND NOTIFY THE ARCHITECT OF ANY CONFLICT ENCOUNTERED. MECHANICAL CONTRACTOR SHALL PROVIDE ALL OFFSETS, ETC. WHICH MAY BE REQUIRED, WITHOUT ADDITIONAL COST TO THE OWNER. 4, ALL SHEET METAL DUCT CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH "SMACNA" LOW PRESSURE DUCT CONSTRUCTION STANDARD. 5. TURNING VANES SHALL BE INSTALLED IN ALL BENDS IN RECTANGULAR DUCT EXCEEDING 30" 6. ALL DUCTS SHALL BE SUPPORTED WITH 1"WIDE, 16 GAUGE, GALVANIZED STEEL BANDS OR AS SHOWNED ON PLANS. 7. ALL RECTANGULAR DUCT SHALL BE INSULATED WITH A MIN. OF 2"INTERNAL LINER, 2 LBS. DENSITY R-8.0 ALL ROUND DUCTS AND DIFFUSER TOPS SHALL HAVE A MIN. 2" THICK OF FOIL BACKED BLANKET TYPE INSULATION R=8, WITH ALL JOINTS BUTTED AND TAPED. 8. ALL DUCT DIMENSIONS SHOWN ON PLANS ARE INTERNAL 9. MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF SUPPLY AND RETURN AIR REGISTERS, DUCTS, GRILLES AND DIFFUSERS WITH LIGHTING AND CEILING PATTERNS. 10. PROVIDE LATERAL BRACING OF ALL DUCTS AND PIPES AS REQUIRED BY CODE. 11. AIR HANDLING DUCT SYSTEM SHALL BE CONSTRUCTED, INSTALL, INSULATED AND SEALED AS REQUIRED BY 2012 UMC. AND LATEST SMACNA GUIDELINES. 12. MOUNT ALL THERMOSTATS BETWEEN 36"-48" ABOVE FINISHED FLOOR. 13. ALL BRACING OF DUCTS AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES. 14. WHERE BRACING DETAILS ARE NOT SHOWN ON THE DRAWINGS OR IN THE GUIDELINES, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT OR MECHANICAL ENGINEER. 15. A COPY OF THE GUIDELINES PUBLISHED BY "SMACNA" SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR AND KEPT ON THE JOB AT ALL TIMES. 16. ALL DUCTWORK ABOVE ROOF SHALL BE INTERNALLY LINED. 17. INSULATION APPLIED TO THE EXTERIOR SURFACE OF DUCTS LOCATED IN BUILDINGS SHALL HAVE A FLAME SPREAD OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED AS A COMPOSITE INSTALLATION INCLUDING INSULATION, FACING MATERIALS, TAPES AND ADHESIVES AS NORMALLY APPLIED. 18. OUTSIDE AIR DUCTS SHALL HAVE 1 /4"MESH SCREEN, BACKDRAFT AND VOLUME DAMPERS. 19. FURNISH AND INSTALL MANUAL VOLUME DAMPERS ON ALL BRANCH DUCTS SERVING A SUPPLY OR RETURN AIR REGISTER. NO EXCEPTIONS. INSTALL VOLUME DAMPERS DIRECTLY ABOVE T-BAR CEILING FOR ACCESSIBILITY. IF ACCESS IS NOT FEASIBLE, NOTIFY THE ARCHITECT AND ENGINEER FOR A POSSIBLE RELOCATION. 20. MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF SUPPLY AND RETURN AIR REGISTERS, DUCTS, GRILLES AND DIFFUSERS WITH LIGHTING AND CEILING PATTERNS. 21. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GF•nAL LOCATION, TYPE, LAYOUT AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. REFER TO ARCHITECTURAL AND MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTAL LATION REQUIREMENTS, AS REQUIRED. FURNISH AND INSTALL DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT MANUFACTURE. 22. CODE COMPLIANCE: ALL WORK COVERED BY THE SECTION SHALL CONFORM TO THE UNIFORM MECHANICAL CODE 2012 EDITION AND OTHER AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICT BETWEEN REQUIREMENT, THE MOST RESTRICTIVE ONE SHALL APPLY. 23. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURN': HED BY OTHERS, AND REQUIREMENTS OF THE OWNER. PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. WORK SHALL BE PERFORMED BY EXPERIENCED TRADESMEN AND THEIR WORK SHALL BE OF HIGH STANDARD ACCEPTABLE TO THE ARCHITECT. 24. DUCTWORK: DUCT SYSTEMS SHALL BE RIGID AND SHALL BE CONSTRUCTED, INSTALLED, SEALED AND INSULATED AS PROVIDED IN THE CALIFORNIA MECHANICAL CODE. SHEET METAL SHALL BE IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS. SHEET METAL SHALL BE GALVANIZED SHEET METAL OF LOCK -FORMING QUALITY, ASTM A-525. UNLESS OTHERWISE NOTED, DUCT DIMENSIONS ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS ON LINED DUCTS, OR SHEET METAL DIMENSIONS ON UNLINED DUCTS. ALL ANGLE IRON ANGLE USED FOR SUPPORT SHALL BE GALVANIZED. ROUND RIGID DUCTWORK SHALL CONFORM TO SMACNA TABLE 3-2. 25. SEAL ALL DUCT SEAMS, TRANSVERSE AND LONGITUDINAL, AIR- TIGHT. PROVIDE TURNING VANES AT ALL ELBOWS OR OFFSETS EXCEEDING 30 DEGREES. PER 2012 UMC. 26. ACCESS DOOR: PROVIDE HINGED ACCESS PANELS IN DUCTWORK WHERE SHOWN AND AS REQUIRED FOR ACCESS TO DAMPERS OR EQUIPMENT. PROVIDE INSULATED ACCESS DOORS IN INSULATED DUCTWORK. 27. TEST AND ADJUST EACH PIECE OF EQUIPMENT AND EACH SYSTEM AS REQUIRED TO ASSURE PROPER BALANCE AND OPERATION. PROVIDE A CERTIFIED AIR BALANCE REPORT TO THE OWNER SHOWING DESIGN AND MEASURED AIR VOLUMES, STATIC PRESSURES, FAN RPMS, ETC. ELIMINATE NOISE AND VIBRATION, AND ASSURE PROPER FUNCTION OF CONTROLS, MAINTENANCE OF TEMPERATURE, COMPLIANCE AND OPERATION. OBTAIN INSPECTIONS REQUIRED BY LOCAL CODE. GUARANTEE THE WORK AND THE INSTALLATION FOR ONE YEAR AFTER ACCEPTANCE BY THE OWNER. FURNISH THE OWNER WITH TWO COMPLETE SETS OF AS -BUILT DRAWINGS INDICATING ALL INSTALLED WORK INCLUDING ALL CONTROL WIRING DIAGRAMS AND INTERLOCK FOR SYSTEM OPERATIONS. CERTIFIED AIR BAL "NCE P.- IEVVED FOR REPORT AND OUTSIDE AIR CERTIFICAITON ARE REQUIRED PRIOR TO OCCUPANCY. CODE 28. FIRE DAMPERS SHALL BE FIRE MARSHALL APPROVED AND STRICTLY PER MANUFACTURER'S PRINTED PPROVED MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE TO THE INSPECTING AUTHORITIES. ADDITIONAL PLANS NOTES /1-) City of Tukwila BUILDING DIVISION JAN 0 8 2015 1. FOR EXACT LOCATION OF SUPPLY, RETURN DIFFUSERS AND REGISTERS REFER TO ARCHITECTURAL REFLECTED CEILING PLAN. 2. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS. BY THE ACT OF SUBMITTING A BID, THIS CONTRACTOR ACCEPTS THE CONDITIONS UNDER WHICH HE WILL BE REQUIRED TO WORK. 3, THIS CONTRACTOR SHALL COMPLY WITH ALL CONTRACT DOCUMENTS IN LAYING OUT HIS WORK AND EQUIPMENT. HE SHALL COORDINATE THE WORK OF THE SECTION WITH THE WORK OF OTHER TRADES AND ALL JOB CONDITIONS. 4. ANY APPARATUS, APPLIANCE, DEVICE, MATERIAL, OR WORK NOT SHOWN ON DRAWING BUT MENTIONED IN THE SPECIFICATIONS, OR VICE VERSA, OR ANY INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE WORK COMPLETE AND PERFECT IN ALL RESPECTS AND READY FOR OPERATION, EVEN IF NOT PARTICULARLY SPECIFIED, SHALL BE FURNISHED, DELIVERED, AND INSTALLED BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO THE OWNER. 5. ACCESS AND WORKING SPACE MUST BE PROVIDED AND MAINTAINED ABOUT ALL MECHANICAL, ELECTRICAL, AND CONTROL EQUIPMENT TO PERMIT READY AND SAFE OPERATION, EXAMINATION AND MAINTENANCE AS REQUIRED BY GOVERNING CODES. 6. FLASHING, COUNTER -FLASHING AND ROOF MEMBRANE PATCHES OF ALL MECHANICAL OPENINGS IN ACCORDANCE WITH THE REQUIREMENTS OF THE EXISTING ROOFING SYSTEM. 7. JOINTS AND OFFSETS FOR PIPE MOVEMENT SHALL USE NORMALLY ACCEPTED METHODS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND RELATED SECTIONS OF 2012 UMC. 8. DRAWINGS AND SCHEMATIC PLANS MAY NOT INDICATE ALL CODE REQUIRED PIPING SUPPORTS AND SEISMIC SUPPORTS. CONTRACTOR SHALL FIELD VERIFY, MEASURE, COUNT AND INCLUDE IN HIS BID/PRICE THE SUPPORTS AND SEISMIC BRACINGS. 9. WHEN THERE IS A CONFLICT BETWEEN SPECIFICATION AND DRAWINGS THE MOST STRINGENT DOCUMENT SHALL GOVERN. 2.1 Town PLU PG FAO U PI ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup.com STAMP EXPIRES 03-19-16 7 PROJECT NAME/ADDRESS: GRILL CITY CRISPY T SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: 11>11>R(1>11>j> RECEIVED CITY .OF.-TUKWILA JAN 0 6 2015 PERMtT...CENTER.... . ISSUE DATE: 1ST 2ND .......................... 3RD 4TH 5TH 6TH C..OR LTR# JOB NUMBER PROJECT #: 141112 DRAWN BY SHEET CONTENT MECHANICAL LEGEND AND GENERAL NOTES SHEET NO -0.1 HOOD INFOR HOOD NO TAG MODEL LENGTH MAX, C❑❑KING TEMP, EXHAUST PLENUM TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD C❑NFIG, TOTAL EXH, CFM RISER(S) END TO END ROW WIDTH LENG. DIA, CFM S.P. © Grill City 4824 NDI 6' 10,00" 600 Deg, 3000 14" 20" 3000 —0,475" 0 430 SS Where Exposed ALONE ALONE v © Grill City 146 MISC—PSP 7' 0.00" 300 Deg 0 1200 Where Exposed ALONE ALONE © Crispy Town 4824 NDI 5' 2,00" 400 Deg' 1800 13" 13" 1800 —0.359" 0 430 SS Where Exposed ALONE ALONE © © Crispy Town 146 5' 4,00" 300 Deg, 0 800 430 SS Where Exposed ALONE ALONE VIP'MISC—PSP HOOD INFORM HOOD NO, TAG FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIP[NG HOOD HANGING WGHT TYPE QTY. HEIGHT LENGTH EFFICIENCY @ 9 MICRONS QTY. TYPE WIRE GUARD LOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY AM Grill City SS Baffle with Handles 10 16 16 307. 4 L55 Series E26 NO NJ 334 LBS 0 © Grill City 0 NO 71 LBS firk Crispy Town SS Baffle with Handles 6 16 16 307.4 L55 Series E26 NO NO 307 LBS (H4) Crispy Town 0 NO 60 LBS HOOD OPTIONS HOOD NO, TAG ❑PTI❑N © Grill City LEFT END STAND❑FF(FIN/INS— ISLAND) 1" Wide 48" Long Insulated B RIGHT END STAND❑FF(FIN/INS— ISLAND) 1" Wide 48" Long Insulated © Crispy Town LEFT END STAND❑FF(FIN/INS— ISLAND) 1" Wide 48" Long Insulated © RIGHT END STAND❑FF(FIN/INS— ISLAND) 1" Wide 48" Long Insulated PERFORATED SUPPLY PLENU. HOOD N❑ TAG P❑S, LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG, DIA, CFM S.P. H Grill City Front 84" 14" 6" MUA 12" 24" 600 0,162" 2 H Crispy Town Front 64" 14" 6" MUA 12" 28" 798 0,205" 4 EXHA UST FAN INFORMA FAN UNIT NO, TAG FAN UNIT MODEL # CFM ESP, RPM H.P. 0 VOLT FLA DISCHARGE VEL❑CITY WEIGHT (LBS.) S❑NES Grill City NCA24HPFA 3000 1,750 972 2.000 3 208 6,2 238 21 (EF\) Crlspy Town CASRE18BDHP 1800 2,250 1491 2,000 3 208 6,2 1043 FPM 297 22 MUA FAN INFORMATION FAN"�. UNIT NO. TAG FAN UNIT MODEL # BLOWER H❑USING CFM ESP, RPM H.P. 0 VOLT FLA WEIGHT (LB ..u. ONES U Grill City Al—G10 G10 Al 2700 0,750 995 1,500 3 208 4,7 238 23 1 Crispy Town Al—G10 G10 Al 1620 0.750 859 0,750 3 208 2,7 231 pi 16,8 2 k,. FAN OPTIONS FAN UNIT NO. TAG OPTION (Qty. — Descr.) EF-1 Grill City 1 — Grease Box EF-2 Crispy Town 1 — Utility Set Grease Cup FAN ACCESSORIES FAN UNIT NO, TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT EF-1 Grill City YES RF-2 Crispy Town YES MUA-1 Grill City MUA-2 Crlspy Town URB ASSEMBLIES' N❑, FAN WEIGHT ITEM SIZE EF-1 # 1 48 LBS Curb 31.500"W x 31,500"L x 20,000"H Vented Hinged EF-2 # 2 30 LBS Curb 26,500"W x 26.500"L x 24.000"H Vented MUA-1 # 3 29 LBS Curb 21,000"W x 21,000"L x 15.000"H MUA-2 # 4 29 LBS Curb 21,000"W x 21,000"L x 15,000"H GRILL CITY AIR BALANCE SCHEDULE UNIT TYPE MAKE/MODEL SUPPLY O.S.A. % O.S.A. RETURN EXHAUST MAKE-UP PRESSURE EXISTING FAN COIL UNIT YORK 1600 160 10.0 1440 - - 160 KITCH. HOOD EXH. FAN CAPTIVEAIRE NCA24HPFA - - - - -3000 - -3000 KITCH. HOOD MUA FAN CAPTIVEAIRE Al-G10 - 2700 100 - - 2700 2700 TOTAL - 1600 2860 - 1440 -3000 2700 -140 -5% Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2012 IMC 107.2.4 & IMC 506.3.2.5) GREASE DUCT TEST (2012 IMC 506.3.2.5) Prior to the use or concealment of any portion of a grease duct system, a leakage test shall be performed. Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. A light test shall be performed to determine that all welded and brazed joints are liquid tight. A light test shall be performed by passing a lamp having a power rating of not less than 100 watts through the entire section of ductwork to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular to the duct walls. A test shall be performed for the entire duct system, including the hood -to -duct connection. The duct work shall be permitted to be tested in sections, provided that every joint is tested. For listed factory -built grease ducts, this test shall be limited to duct joints assembled in the field and shall exclude factory welds. 2012 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided whenever the exhaust system is in operation. Makeup air intake opening locations shall comply with Section 401.4. N0 "''SUBMITTAL OF A CERTIFIED AIR BALANCE REPORT AND OUTSIDE AIR CERTIFICATION ARE REQUIRED PRIOR TO OCCUPANCY. CRISPY TOWN AIR BALANCE SCHEDULE UNIT TYPE MAKE/MODEL SUPPLY O.S.A. % O.S.A. RETURN EXHAUST MAKE-UP PRESSURE EXISTING FAN COIL UNIT YORK 600 50 8.3 550 - - 50 KITCH. HOOD EXH. FAN CAPTIVEAIRE CASRE1880HP - - - - -1800 - -1800 KITCH. HOOD MUA FAN CAPTIVEAIRE Al-G10 - 1620 100 - - 1620 1620 TOTAL - 600 1670 - 550 -1800 1620 -130 -7% OJ\- LOW .D I- SS,R- 3 3„CTWORK SINGLE LINE DIAGRAM DOUBLE LINE CONFIGURATION SINGLE LINE DIAGRAM CONFIGURATION DOUBLE LINE RECTANGULAR DUCT ID" D"0 X xY' X"xY" X"xY' D"0 ROUND CONICAL DUCT FITTING D" RECTANGULAR D„� TO ROUND TRANSITION D20 D10 D20 Di' — D — — 10 1 ° D„0 1 & REDUCING D30 FITTING D'30 D"10 D'20 Dug 45°LATERAL D'i0 ROUNDTO D20 FITTING TRANSIDTION 45' LAT. -I D THIS PORTION FOR CONTINUING D20 D'30 FITTING yJ 2 DUCT RUN D"10 45° LATERAL D„ 0 .. 6" D"10 D„ O 2 & REDUCING j �V EMU FITTING al o D 0 6„ ' Irat 1 D'30 .. D'20 MIN. ma g 45' FITTING LATERAL D30 �► 90° ELBOW D'30 ECTA\CULA LOW 3ESS.E DJCTWO< SINGLE LINE DIAGRAM DOUBLE LINE CONFIGURATION SINGLE LINE DIAGRAM DOUBLE CONFIGURATION LINE 5 W 1/2 / / > / \ 5 1/2 Rf' R=W � / / 1 1 ow_ mill EN III T / T II a i �T� a T ■ • ili { 45° D/2 ;, W/2 C.D. W / C.D. f \ DIFFUSE/EGISTE� SCHEDULE NECK SIZE TYPE ICFM MAX. 6" 0, 6 x 6 S-1=CEILING DIFFUSER * 100 8"0, 8 x 8 R-1=RETURN AIR REG. I* 180 10"0, 10 x 101 E-1=EXHAUST AIR REG.; *300 12" 0 12 x 12 T-1=TRANSFER GRILLE *400 14"0 14 x 14 *500 16" 0 16 x 16 *600 1 * FOR SUPPLY ONLY X/' TAG TYPE /� CFM "SIZE" REFERS TO "NECK". DIFFUSER FACE TO BE 24x24 FOR T—BAR CEILINGS. T—BAR CEILINGS, PROVIDE QUAD DMPRS IN DUCTS GYP CEILINGS, PROVIDE OBD AT GRILLES LCW DUCT SIZ 3 �ESS„R E i\c SC-EDJLE CFM UP TO 100 101 TO 140 ROUND DUCT DIAMETER OR EQUIVALENT RECTAGULAR DUCT * 4" x 8" OR 6"0 7" x 6" OR 7"0 141 TO 220 8" x 7" OR 8"0 221 TO 260 8" x 8" OR 9"0 261 TO 400 10" x 8" OR 10"0 401 TO 700 14" x 8" OR 12"0 701 TO 1000 1001 TO 1200 1201 TO 1800 1401 TO 2400 2401 TO 3000 20" x 8" OR 14"0 24" x 8" OR 16"0 24" x 12" OR 18"0 30" x 12" OR 20"0 ....................... 24" x 16" OR 22"0 * CLEAR INSIDE DIMENSION OF DUCT UNLESS OTHERWISE NOTED. FF. sr Rs/Rh G STFRS SC HDLP TAG S-1 S-2 S-3 S-4 S-5 R-1 R-2 R-3 MANUFACTUR TITUS TITUS TITUS TITUS TITUS MODEL 250—AA TMS—AA FL-15-10 PAS —AA TMRA—AA TITUS 4FL—NT TITUS TITUS 350FL 50E—NT TYPE ARCH LAY —IN ARCH SURFACE CEILING MOUNTED LINEAR DIFFUSER SERVICE SUPPLY SUPPLY SUPPLY ARCH PERF, LAY —IN SUPPLY ROUND SUPPLY ARCH LAY —IN ARCH SURFACE ARCH LAY —IN RETURN RETURN RETURN MATERIAL MAX, NC ALUMINUM 25 ALUMINUM 25 ALUMINUM 25 ALUMINUM 25 ALUMINUM 25 ALUMINUM ALUMINUM ALUMINUM 25 25 25 NOTES 1, 2. 4. 5 & 6 1. 3, 4, 5 & 7 1, 3. 5 & 6 1. 2. 4. 5 & 6 1, 3, 4. 5 & 8 1, 2, 5 & 6 1. 3, 5 & 7 1, 2, 5 & 8 REVIEWED R r- ©R CODE COMPL€ANCE APPROVED JAA 5 City of Tukw la ............................... BUILDING DIVISION N❑TES+ 1, OFF—WHITE BAKED ENAMEL FINISH 2, LAY —IN FRAME 3, SURFACE MOUNT FLANGED FRAMED W/SCREW FASTENING 4. OPPOSED BLADE DAMPER 5, SQUARE T❑ ROUND ADAMPER WHERE REQUIRED 6, 24x24 FACE 7, 12x12 FACE 8, VOLUME DAMPER AND AIR EXTRACTOR 9, 1/2"X1/2"X1/2"ALUMINUM GRID FACE TYPE: RD — ROUND PR — PERFORATED SW — SIDEWALL DISCHARGE MOUNTING: FL — FLUSH S — SURFACE PATTERN: DAMPERS: ADJ — ADJUSTABLE VD — VOLUME DAMPER 4W — FOUR WAY FIX — FIXED FINISHES: W— WHITE MATERIAL: ST - STEEL AL — ALUMINUM ris.y Town PL.UMPGROUP! ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup.com STAMP EXPIRES 03-19-16 7 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: ®®®®®©`D ISSUE DATE: 1ST...... 2ND.... 3RD 4TH..... 5TH 6TH RECEIVED• CITY ....OF....TUKWILA ................... JAN..O 6...2015.... PERMIT CENTER JOB NUMBER PROJECT*: 141112 DRAWN BY SHEET CONTENT MECHANICAL EQUIP. SCHEDULES SHEET NO M-O.2 \ /. \ \ \\ j'/ / \ `\' / /: 24x12 DN TO HOOD (TYP. 2) / / , / 7 ,' .; / // 20x14 DN TO HOOD (E) / // , J // l , .�'N /, / /' / ,'\) /r> / /' / / / / // / / / / ' /� . . ' 1 / 11 1 / A- GRILL CITY FLOOR PLAN SCALE: 1 /4"=1 '-0" 20x144 KEYNOTES: INSTALL NEW KITCHEN EXHAUST HOOD WITH CONNECTING DUCTWORK AS SHOWN. REFER TO DRAWING M-3.0 DETAILS 6 & 9. PROVIDE AN ANSUL FIRE PROTECTION SYSTEM AT THE HOOD WITH A PUSH BUTTON SWITCH. INSTALL NEW KITCHEN MAKE-UP AIR HOOD WITH CONNECTING DUCTWORK AS SHOWN. REFER TO DRAWING M-3.0 DETAILS 5 & 8. ROUTE EXHAUST DUCT RISER UP THRU ROOF IN DUCT SHAFT. COORDINATE WITH ARCHITECT FOR EXACT LOCATION. HORIZONTAL GREASE DUCT SHALL SLOPE AND DRAIN IN COMPLIANCE WITH CODE. ALL GREASE HOOD EXHAUST DUCTWORK SHALL BE WRAPPED WITH APPROVED 2 LAYER FIRE RATED GREASE DUCT INSULATION. ROUTE NEW MAKE-UP AIR DUCT RISER UP THRU ROOF IN EXISTING DUCT SHAFT. EXISTING FAN COIL UNIT TO REMAIN AND BE REUSED. EXISTING CEILING DIFFUSER TO REMAIN AND BE REUSED. EXISTING RETURN AIR REGISTER TO REMAIN AND BE REUSED. TYP. ii rt I1i •Iifi i ili + 111� II iT Ili .2 Ill lli li iillll I Ill Dili. INSTALL NEW WALL MOUNTED KITCHEN HOOD SWITCH TO ENERGIZE NEW EXHAUST FAN EF-1 AND NEW MAKE-UP AIR FAN MAU-1. PROVIDE AND INSTALL NEW PULL STATION TO START KITCHEN HOOD FIRE SUPPRESSION SYSTEM. LOCATE PULL STATION IN COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS. DUCT SYSTEMS SERVING TYPE I HOOD SHALL BE CONSTRUCTED AND INSTALLED IN COORDINATION WITH ALL OTHER TRADES SO THAT GREASE CAN NOT COLLECT IN ANY PORTION THEREOF, AND THE SYSTEM SHALL SLOPE NOT LESS THAN 1 /4 PER LINEAR FOOT TOWARD THE HOOD OR TOWARD A GREASE RESERVOIR IN COMPLIANCE WITH 2012 IMC SEC. 506.3.7. INSTALL GREASE DUCT CLEANOUTS AND OPENINGS NOT MORE THAN 20 FEET APART IN COMPLIANCE WITH 2012 IMC SECTIONS 506.3.8 AND 506.3.9. GREASE DUCT HORIZONTAL LENGTH: 54'-1 1 ". GREASE DUCT TOTAL LENGTH: 65-0". REVIEWED FOR CODE COMPLIANCE APPROVED JAN 08 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 6 2015 PERMIT CENTER ��1101 rispy Town PLUMPGROUPI ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup.com STAMP EXPIRES 03-19-16 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CI1Y SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 .......... 1ST 2ND 3RD._. 4TH 5TH 6TH REVISIONS: — CITY CORRECTIONS 12/29/14 ISSUE DATE: JOB NUMBER PROJECT #: 141112 DRAWN BY . SHEET CONTENT MECHANICAL FLOOR PLAN SHEET NO M-1.O < '" \ /// efr (1 (TYP.2) 12x12 UTR TO EF-2 0 L I.� l I. 16x10 EAD 16x10 EAD 11'-9" LONG) 22x12 SAD 22x12 SAD 28x12 DN TO HOOD 13x13 DN TO HOOD CRISPY TOWN FLOOR PLAN 16x16 UTR4 TO MUA-2 /; c_> 7 _,/ ( '1 i i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ity of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 6 2015 Town PLU IPGROUP ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup•com STAMP EXPIRES 03-19-16 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: ®®®�®©'D — CITY CORRECTIONS 12/29/14 ISSUE DATE: 1ST...... 2ND 3RD 4TH 5TH 6TH JOB NUMBER PROJECT*: 141112 DRAWN BY SHEET CONTENT MECHANICAL FLOOR PLAN SHEET NO M-1.1 SCALE: 1/4"=1'-0" R - CST NN \ ♦ \ I� OSA IMO J ti CRISPY TOWN ROOF PLAN SCALE: 1/4"=1'-0" MUNN I • I L_J WNW 14111111111 0 / T i /ff/ / KEYNOTES: 0 MOUNT NEW KITCHEN HOOD EXHAUST FAN ON ROOF VENTED CURB DIRECTLY ABOVE DUCT SHAFT. FIELD VERIFY AND COORDINATE WITH ARCHITECT FOR EXACT LOCATION. REFER TO DRAWING M-3.0 DETAILS 4 & 7. IF EXHAUST FAN IS LOCATED WITHIN 10 FEET OF OUTSIDE AIR INTAKE(S), RAISE THE EXHAUST FAN A MINIMUM OF 3'-0". CD 0 MOUNT NEW MAKE-UP AIR FAN ON ROOF CURB. OUTSIDE AIR EXTENSION INTAKE SHALL BE A MINIMUM OF 10'-0" AWAY FROM ALL EXHAUST FANS AND VENT PIPES. REFER TO DRAWING M-3.0 DETAIL 10. RELOCATE EXISTING ROOF MOUNTED MAKE-UP AIR FAN SERVING EXISTING KITCHEN HOOD. COORDINATE WITH ARCHITECT FOR EXACT LOCATION. PROVIDE DUCTWORK FROM FAN TO REMAINING DUCTWORK. O4 MOUNT NEW ROOF MOUNTED MAKE-UP AIR FAN SERVING KITCHEN HOOD NO. H-4. ON ROOF CURB. COORDINATE WITH ARCHITECT FOR EXACT LOCATION. REFER TO DRAWING M-3.0 DETAIL 10. 0 RELOCATE EXISTING ROOF MOUNTED EXHAUST FAN SERVING THE TRASH COMPACTOR. COORDINATE WITH ARCHITECT FOR EXACT LOCATION. GRILL CITY ROOF PLAN SCALE: 1 /4"=1 '-0" MINN WNW.. ROAM PPM. MIN. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 8 2015 City of Tukwila BUILDING DIVISION ■ Town PLU PG ROU P ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup.com STAMP EXPIRES 03-19-16 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: — CITY CORRECTIONS 12/29/14 ISSUE DATE: 1ST 2ND 3RD 4TH 5TH 6TH..... RECEIVED CITY OF T.U_KWILA JAN .. 0.6.. 2015... ................................. PERMIT CENTER .............. JOB NUMBER PROJECT #: 141112 DRAWN BY SHEET CONTENT MECHANICAL ROOF PLANS SHEET NO -2.0 1' LAYER OF INSULATION FACTORY INSTALLED IN 1.00' END STANDOFF MEETS 0' REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES, 48' 1' -- U.L. List q§, Serf s E26 Canopy Light FI ture - HIghhHHHH1I Temp Assembly 31' 5' 2.00'Nom,/5' 2.00'0D 5'-4,00' Overall Length 31' -- 1' 1' LAYER OF INSULATION FACTORY INSTALLED IN 1.00' END STANDOFF MEETS 0' REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. KITCHEN HOOD (H-3) PLAN SCALE: 1' LAYER OF INSULATION FACTORY INSTALLED IN 1.00' END STANDOFF MEETS 0' REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 5 ) 48' 1' LAYER OF INSULATION FACTORY INSTALLED IN 1.00' END STANDOFF MEETS 0' REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 0 14' 11 0 24' U,L, Listedl L55 Safpes E26 Canopy Light Flx Lire Ht$-1 Temp AAssembly 0 0 41' 6' 10,00'Nom./6' 10.00'OD 7'-0,00' Overall Length 41' 1' BALANCE DAMPERS HANGING ANGLE 16' SS BAFFLE WITH HANDLES AND HOOK 3' INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP TEMP SENSOR 4' 60' SCREW IN COMPACT FLUORESCENT BULB, INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE FIELD WRAPPER 16,00' HIGH _(SEE HOOD OPTIONS TABLE) DROP CELING @ 9'10' ABOVE FINISHED FLOOR 48.0' MAX EQUIPMENT BY OTHERS l 24' NOM, 84' AFF TYP. FOR C❑NNECTI❑N TO STRUCTI❑N SEE DET. DUCT. G,I, STRAP DUCT HANGER 6'-0" O.C. SEE SCHEDULE FOR SIZE, w10 S.M.S. TYPICAL SUPP❑RTING STRUCTURAL MEMBER, DIAG. BRACING MAY BE ❑MMITTED, TYP, TYPICAL ROUND 1-1/2"xl-1/2"x16 GA, GI, DIAG❑NAL BRACE 16'-0" ❑,C. MAX. SPACING ALTERNATE SIDES EVERY BRACE TYPICAL, MAX. RECTANGULAR DUCT DIMENSI❑N ROUND OR OVAL DUCT MAX. SPACING EACH HANGER HANGER SIZE UP TO 16" TO 9" DIA. 72" 1-1/2"x18" GA. 16" TO 30" 9" TO 26 DIA. 160" 1-1/2"x16" GA. NONE 12 KITCHEN HOOD (H-1) PLAN SCALE: NONE 9 KITCHEN HOOD (H-1 & H-3) SECTION SCALE: NONE 6 DUCT SUPPORT DETAIL SCALE: 1 1' - 7' 12' 32' 2 5' 4,00'Nom,/5' 4.00'OD KITCHEN HOOD (H-4) PLAN SCALE: 14' 1 - 7 '12' 21' 2 42' 2 7' 0,00'Nom./7' 0.00'0D EXHAUST RISER HANGING ANGLE 16' CAPTRATE SOLO FILTER WITH HOOK 3' INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP -4' 16' 48.0' BAC(SPLASH 80.80' HIGH X 87.00' LONG EQUIPMENT BY OTHERS MAX SCREW IN COMPACT FLUORESCENT BULB, INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE FIELD WRAPPER 16.00' HIGH (SEE HOOD OPTIONS TABLE) ATTACHING PLATES SUPPLY RISER WITH ,VOLUME DAMPER 23.5X OPEN STAINLESS �- STEEL PERFORATED PANEL -6 24' NOM. 80' AFF TYP, au 3/8"ALL THREAD ROD HANGER ANGLE CLIP WITH L❑CKING NUTS TOP AND BOTTOM SPIRAL MAIN DUCT - HANGING RING C❑NICAL FITTING (TYP) NOTE SWAY BRACING NOT REQUIRED IF DUCTS HANG LESS THAN 12° FROM BOTTOM OF SUPPORTING STRUCTURE. NONE AIRCRAFT CABLE 7-19 CEILING LEVEL 3 3/8"ALL THREAD ROD WITH LOOP AT BOTTOM TO SUPPORT THE DUCT, DOUBLE DEFLECTI❑N SIDE DISCHARGE GRILLE VOLUME DAMPER. NONE 11 KITCHEN HOOD (H-2) PLAN SCALE: NONE 8 KITCHEN HOOD (H-2 & H-4) SECTION SCALE: NONE 5 SPIRAL DUCT DETAIL SCALE: 32 1/8" AIRFL❑W SERVICE DISC❑NNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24" SERVICE "CLEARANCE REQ. " 21" MAKE= -UP AIR FAN DETAIL SCALE: NONE 10 24' 15 3/8 33 1/2 LOCK & SPRING PIN 23 3/4 t � V 2' DRAIN 28 40 57 1/2 m m mm MS OM MS Eft MM MS MS Mft 6 1/4' m m OM OM OM MS OS MS MS OS MM MS 12 3/16 29 1/2 i 16 1/2 EXHAUST FAN EF-2 DETAIL 24 26 1/2 DUCTWORK BETWEEN EXHAUST RISER ON H❑O AND FAN (BY OTHERS) SCALE: NONE 7 D 43 3/8 37 1/2 L7 -D n 1 1� 30 5/8 REASE DRAIN 2 23 7/8 28 33 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) EXHAUST FAN EF-1 DETAIL SCALE:. NONE 4 WALL SWITCH WITH PILOT LIGHT MOUNTED ON WALL IN KITCHEN NEXT TO HOOD BY E.C, 208V-30 C.B. D.S. rEF L MAGNETIC MOTOR STARTER WITH 120V OUTPUT XFMR AND AUX, CONTACT BY E.C., TYP 2 MICRO —SWITCH IN FIRE SUPPRESSION CONTROL SYSTEM PANEL, TYPICAL FOR GAS SOLENOID SHUTOFF VALVE 0 0 0 208V-30 NONE 2 CCT BREAKER(TYP) REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 8 2015 (c-f IV UA city Of Tukwila Ua BUILDING DIVISION KITCHEN HOOD CONTROL DIA ■ s Town P'LU P G ROU Pg ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1.834 www.plumpgroup.com STAMP EXPIRES 03-19-16 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: 11›1>ID>p>i>1.> ISSUE DATE: 1ST ................ 2ND 3RD 4TH 5TH 6TH .R-aCE,V ......................... CITY ....O.F....TUKWIL ',,....... JAN...0 6 2 C 15 PERMIT CENTER JOB NUMBER PROJECT #: 141112 DRAWN BY SHEET CONTENT MECHANICAL DETAILS SHEET NO -3.0 SCALE: GASKET GASKET REGULATOR L❑CKNUT BLADE SHALL BE 16 GAGE GALVANIZED STEEL 3/8" ROD 1" WIDE x 16 GAGE GALVANIZED STRAP (2 REQ'D) INDICATING HANDLE AND LOCKING QUADRANT 3/8" SQ. ROD W/SET SCREWS (2 REQ'D) 1.5" ULTRALITE 3 LB DENSITY NING CLIP DUCT AX E 12" TYP. NOTE: 1. INSIDE DUCT SURFACE TO BE SPRAYED WITH BONDWELL C-1005 PRIOR TO APPLYING LINER NONE 11 SCALE: NONE 8 ROUND VOLUME DAMPER DETAIL SCALE: NONE 5 DUCT PLENUM LINING DETAIL SCALE: 3/8" SQ. RO END BEARING DUCT BRANCH 45 DEG. ANGLE HAND DAMPER WITH LOCKING TYPE INDICATOR QUADRANT 1/3 W. 5" MINIMUM CINCH COLLAR NOTES: FURNISH THIS TYPE OF CONNECTION WHEN SINGLE —LINE DUCTWORK IS INDICATED AS THIS FOR ERANCHES WITH LESS THAN 25% OF THE TOTAL AIR FLOW. RECTANGULAR DUCT CONN. FLEXIBLE DUCT TO PLENUM OR DIFFUSER MAX. LENGTH 7 —0' VOLUME DAMPER ASEREQUIRE L \ MAIN DUCT -45 DURESS NOTES: FURNISH THIS TYPE OF CONNECTION WHEN SINGLE —LINE DUCTWORK IS INDICATED AS THIS FOR BRANCHES WITH LESS THAN 25% OF THE TOTAL AIR FLOW. ROUND DUCT BRANCH CONN. ROUND OR RECTANGULAR VOLUME DAMPER NOTES: FURNISH THIS TYPE OF CONNECTION WHEN SINGLE —LINE DUCTWORK IS INDICATED AS -'THIS FOR BRANCHES WITH LESS THAN 25% OF THE TOTAL AIR FLOW. ROUND DUCT BRANCH CONN. VOLUME DAMPER MAIN DUCT FLEXIBLE DUCT TO TROFFER OR DIFFUSER MAX. HEIGHT 7'-0 SHEET METAL AS REQUIRED NOTES: FURNISH THIS TYPE OF CONNECTION WHEN SINGLE —LINE DUCTWORK IS INDICATED AS THIS FOR BRANCHES WITH LESS THAN 25% OF THE TOTAL AIR FLOW. ROUND DUCT BRANCH CONN. SECURE UNIT TO CURB W/ #10 X 3/4 SELF TAPPING TEK SCREWS. LOCATE 6" FROM EACH END AND 12" ON CENTER 16 GA. WELDED EXHAUST DUCT RISER SEE PLAN FOR SIZE. SCALE: NONE 2 LAYER THICK FIRE RATED DUCT WRAP UNIFRAX (FYREWRAP ELITE 1.5) - / / / / / / / 0 0 / GREASE TROUGH NONE 3 FACTORY FURNISHED PRE—FAB ROOF CURB VENTED W/HINGED BASE (MIN. 24" HIGH) ROOF 11 //////// / / //////////////// CEILING 10 SCALE: NONE 7 DUCT BRANCH TAKE -OFF SCALE: NONE 4 GREASE EXHAUST FAN MOUNT. DETAIL ANGLE CLIP AND ANCHOR W/ 3/4" EMBEDMENT (MAX) #12 WIRE (TYP.2 FOR DIFFUSER AND TWO FOR DUCTS WITHIN 5' OF DIFFUSER, DIFFUSER TO BE SUPPORTED FROM STRUCTURE ,r— LJ SECURE TO STRUCTURE ABOVE 1" WIDE METAL STRAPS AC❑USTICAL FLEXIBLE DUCT. 6'-0" LONG VOLUME DAMPER EXHAUST DUCT CONNECT FLEXIBLE DUCT TO COLLAR WITH 22 GAUGE CLAMP AND FOUR SHEET METAL SCREWS AND SEAL WATER BASED SEALANT CEILING CEILING DIFFUSER 1fr a RED 18" STREAMER ALL DAMPERS IN CEILING SUPPLY AIR DUCT MIN, RADIUS EQUAL TO 1.5 X DIAMETER NOTE: INSTALLATION OF RETURN AIR REGISTER IS SIMILAR, EXCEPT PROVIDE FILTER AT REGISTER. DUCT SUPPORT HANGER (TYPICAL) MAKE—UP AIR DUCT 20'-0"(MAX.) SCALE: NONE 2 VENTED ROOF CURB DUCT CLEAN OUT (TYPICAL) RANGE HOOD (H ) 1 4'-0" MAX C 18"(MIN.) UN- CLEAR CEILING CEILING DIFFUSER NON—COMBUSTIBLE CEILING FLOOR SCALE: NONE 9 AIR DISTRIBUTION WITH FLEX DUCT SCALE: NONE 6 INN EXHAUST DUCT MAKE—UP AIR DUCT DUCT SUPPORT HANGERT (TYPICAL) 10'-0"(CLEARANCE MIN.) r OUTSIDE AIR DUCT SUPPORT ROOF REVrEvvzo FOR CODE COMPLIANCE APPROVED ' JAN 0 8 2015 City of Tukwila BUILDING DIVISION NOTES: 0 WRAP KITCHEN EXHAUST DUCTWORK WITH TWO —LAYER FLEXIBLE ENCLOSURE MANUFACTURED BY UNIFRAX (FYREWRAP ELITE 1.5) IN COMPLIANCE WITH 2012 INTERNATIONAL MECHANICAL CODE (IMC) AND UNIFORM MECHANICAL CODE . (UMC). 0 EXHAUST DUCTS SERVING TYPE I KITCHEN HOODS SHALL SLOPE NOT LESS THAN 1/4" PER LINEAR FOOT TOWARD THE HOOD OR TOWARD AN APPROVED GREASE RESERVOIR. WHERE HORIZONTAL DUCTS EXCEED 75' IN LENGTH, THE SLOPE SHALL BE NOT LESS THAN 1" PER LINEAR FOOT IN COMPLIANCE WITH 2012 IMC SEC. 506.3.7 0 WRAP KITCHEN MAKE—UP AIR DUCTWORK WITH INSULATION IN COMPLIANCE WITH 2012 INTERNATIONAL MECHANICAL CODE AND STANDARDS. ® INSTALL GREASE DUCT CLEANOUTS AND OPENINGS IN COMPLIANCE WITH 2012 IMC SECTIONS 506.3.8 AND 506.3.9. PROVIDE AN APPROVED SIGN ON ACCESS OPENING PANELS WORDED "ACCESS PANEL. DO NOT OBSTRUCT." IN COMPLIANCE WITH 2010 IMC SEC. 506.3.12. Q5 PROVIDE A MINIMUM OF 18" CLEARANCE TO COMBUSTIBLE CONSTRUCTION IN COMPLIANCE WITH 2012 IMC SEC. 506.3.6. KITCHEN TYPE 1 HOOD EXHAUST & MAKE-UP AIR SYSTEM' ■ Town PLIJ PCBRJUP ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup.com STAMP EXPIRES 03-19-16 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: — CITY CORRECTIONS 12/29/14 AL ISSUE DATE: 1ST...... 2ND 3RD 4TH 5TH 6TH BECEI'VED........ CITY OF TUKWILA _ JAN....0..6.2015... PERMIT.. CENTER JOB NUMBER PROJECT #: 141112. DRAWN BY SHEET CONTENT MECHANICAL DETAILS SHEET NO PART I - GENERAL A. CONDITIONS 1. GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, SPECIAL CONDITIONS, AND OTHER RELATED PORTIONS OF DIVISION 1, APPLY TO THIS SECTION. B. SUMMARY OF WORK 1. THE WORK INCLUDED CONSISTS OF FURNISHING LABOR, MATERIALS AND EQUIPMENT FOR THE INSTALLATION. IT ALSO INCLUDES PLACING INTO OPERATION A COMPLETE AND OPERABLE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM AS SPECIFIED AND SHOWN. THIS INCLUDES, BUT IS NOT LIMITED TO: HVAC UNITS, EXHAUST FANS, DUCTLESS SPLIT -SYSTEMS, DUCTWORK, AIR DISTRIBUTION, CONTROLS AND ACCESSORIES, EXCEPT AS OTHERWISE NOTED. C. REGULATIONS, CODES, PERMITS AND INSPECTIONS 1. COMPLY WITH NATIONAL, STATE, COUNTY, AND CITY CODES, ORDINANCES, ETC., HAVING JURISDICTION. THIS INCLUDES RULES AND REQUIREMENTS OF UTILITY SERVING AGENCIES. INCORPORATE CODES, ORDINANCES, ETC., INTO THE BASE BID AND INSTALLATION OF WORK. NO ADDITIONAL FUNDS WILL BE ALLOCATED FOR WORK REQUIRED TO CONFORM TO REGULATIONS AND REQUIREMENTS OR TO OBTAIN APPROVAL OF WORK. 3. OBTAIN AND PAY FOR REQUIRED PERMITS AND LICENSES. WHEN REQUIRED BY CODE, WORK MUST BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TO FINAL APPROVAL, FURNISH ARCHITECT WITH CERTIFICATES OF INSPECTION AND APPROVALS BY LOCAL AUTHORITIES. 4. IN ADDITION, THE LATEST ADOPTED EDITION OF THE FOLLOWING CODES AND PUBLISHED STANDARDS SHALL BE ADHERED TO: A. B. C. D. E. F. G. H. J. 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 UNIFORM MECHANICAL CODE (UMC) NFPA STANDARDS ASHRAE HANDBOOKS SMACNA DUCT CONSTRUCTION STANDARDS 2012 UNIFROM PLUMBING CODE (UPC) 2014 NATIONAL ELECTRICAL CODE (NEC) 2012 IBC CITY OF MORENO VALLEY AMENDMENTS 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2012 INTERNATIONAL FIRE CODE (IFC) 5. IEEE COMPLIANCE: A. VOLTAGE, CURRENT AND TOTAL DEMAND DISTORTION LIMITS OF THE ELECTRICAL SYSTEM, WITH VFD'S IN OPERATION SHALL BE IN COMPLIANCE WITH TABLES 10.2 AND 10.3 OF IEEE 519-1992 "IEEE RECOMMENDED PRACTICES AND REQUIREMENTS FOR HARMONIC CONTROL IN ELECTRICAL POWER SYSTEMS", AND AS SPECIFIED IN THIS SECTION. VFD SHALL BE BUILT TO IEEE 587 STANDARD. B. COMPLIANCE OF IEEE 519-1992 SHALL BE AT THE LINE SIDE OF EACH INDIVIDUAL VFD SYSTEM. A VFD SYSTEM SHALL CONSIST OF THE INDIVIDUAL VFD WITH ITS RELATED ISOLATION TRANSFORMER, LINE REACTOR AND/OR FILTERS. D. DESIGN DRAWINGS 1. DESIGN DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED ONLY TO DEFINE THE BASIC FUNCTIONS REQUIRED. PROVIDE LABOR, MATERIAL, ETC., NECESSARY TO ACCOMPLISH THESE REQUIREMENTS. MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SHALL BE CONSIDERED A PART OF THE WORK INCLUDED. NO CHANGES THAT ALTER THE CHARACTER OF THE WORK WILL BE PERMITTED. DO NOT SCALE THE DESIGN DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. 2. IF A CONFLICT OCCURS BETWEEN THE DESIGN DRAWINGS AND SPECIFICATIONS, PROMPTLY NOTIFY THE ARCHITECT AND/OR ENGINEER. AT THAT POINT, AN INTERPRETATION WILL BE MADE BY THE ARCHITECT AND/OR ENGINEER AND SAID DECISION SHALL BE CONSIDERED PART OF THE CONTRACT DOCUMENTS. E. QUALIFICATIONS OF CONTRACTOR AND WORKMEN 1. CONTRACTOR SHALL BE PROPERLY LICENSED TO PERFORM THE WORK. F. BASE BID 1. BASE BID SHALL INCLUDE MATERIALS AND EQUIPMENT SPECIFIED OR SCHEDULED ON THE DRAWINGS. REQUESTS FOR SUBSTITUTION OF MATERIALS AND EQUIPMENT SHALL BE BY ADDITIVE OR DEDUCTIVE ALTERNATE BID ONLY. THE FOLLOWING DATA MUST BE CLEARLY WRITTEN AT THE BEGINNING OF THE ALTERNATE PROPOSAL: A. ADDITIVE OR DEDUCTIVE AMOUNT CLEARLY WRITTEN IN WORDS AND NUMERALS. B. INCREASED OR REDUCED CONSTRUCTION TIME IN DAYS. C. OTHER DEMONSTRABLE BENEFIT, FOR WHICH THE SUBSTITUTION OF SUCH ITEM WILL BE IN THE OWNER'S INTEREST. 2. ONLY THOSE MATERIALS AND EQUIPMENT WHICH ARE SUBMITTED AS AN ALTERNATE BID, WHICH ARE ACCOMPANIED BY THE SUPPORTING DATA INDICATED BELOW WILL BE REVIEWED AND CONSIDERED. G. SUBSTITUTIONS 1. MATERIALS AND EQUIPMENT THAT ARE A SUBSTITUTE FROM THE LISTED MANUFACTURER MAY BE CONSIDERED. PRIOR TO PROPOSING ANY SUBSTITUTE ITEM, CONTRACTOR SHALL SATISFY HIMSELF THAT THE ITEM PROPOSED IS, IN FACT, EQUAL TO THAT SPECIFIED, THAT SUCH ITEM WILL FIT INTO THE SPACE ALLOCATED, THAT SUCH ITEM AFFORDS COMPARABLE EASE FOR OPERATION, MAINTENANCE AND SERVICE, THAT THE APPEARANCE, LONGEVITY, CAPACITY, SUITABILITY, AND ELECTRICAL CHARACTERISTICS ARE COMPARABLE, THAT BY REASON OF COST SAVINGS, REDUCED CONSTRUCTION TIME, OR SIMILAR DEMONSTRABLE BENEFIT, THE SUBSTITUTION OF SUCH ITEM WILL BE IN THE OWNER'S INTEREST. 2. THE BURDEN OF PROOF OF EQUALITY OF A PROPOSED SUBSTITUTION FOR A SPECIFIED ITEM SHALL BE UPON THE CONTRACTOR. CONTRACTOR SHALL SUPPORT HIS REQUEST WITH SUFFICIENT TEST DATA AND OTHER MEANS TO PERMIT THE ENGINEER TO MAKE A FAIR AND EQUITABLE DECISION ON THE MERITS OF THE PROPOSED SUBSTITUTION. INSUFFICIENT SUBMITTAL DATA WILL RESULT IN REJECTION OF THE PROPOSED SUBSTITUTION. ANY ITEM BY A MANUFACTURER OTHER THAN THOSE SPECIFIED, OR OF BRAND NAME, MODEL NUMBER, OR OF GENERIC SPECIES OTHER THAN THOSE SPECIFIED, WILL BE CONSIDERED A SUBSTITUTION. ENGINEER WILL BE THE SOLE JUDGE OF WHETHER OR NOT THE SUBSTITUTION IS EQUAL IN QUALITY, UTILITY AND ECONOMY TO THAT SPECIFIED. 3. APPROVAL OF A SUBSTITUTION SHALL NOT RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR COMPLIANCE WITH ALL REQUIREMENTS OF THE CONTRACT. CONTRACTOR SHALL BEAR THE EXPENSE FOR ANY CHANGES IN OTHER PARTS OF THIS WORK OR OTHER WORK CAUSED BY THE PROPOSED SUBSTITUTION, INCLUDING BUT NOT LIMITED TO STRUCTURAL, ELECTRICAL, PLUMBING, AND ACCESS REQUIREMENTS. 4. IF ENGINEER REJECTS CONTRACTOR'S SUBSTITUTE ITEM ON THE FIRST SUBMITTAL, CONTRACTOR MAY MAKE ONLY ONE ADDITIONAL REQUEST FOR SUBSTITUTION IN THE SAME CATEGORY. 5. ANY EQUIPMENT SUBSTITUTED WITHOUT THE ENGINEER'S WRITTEN APPROVAL WILL BE REMOVED AND REPLACED WITH THE SPECIFIED EQUIPMENT AT THE CONTRACTOR'S EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER. H. SUBMITTALS 1. EQUIPMENT AND MATERIALS: A. CONTRACTOR SHALL HAVE APPROVED SUBMITTALS PRIOR TO FABRICATION OR DELIVERY OF ANY MATERIAL AND/OR EQUIPMENT TO THE JOB SITE. SUBMIT A MINIMUM OF 8 (EIGHT) COPIES, COMPREHENSIVELY INDEXED SUBMITTALS IN A 3-RING BINDER, COMPLETELY DESCRIBING EACH MAJOR SYSTEM, MATERIAL AND EQUIPMENT PROPOSED TO BE USED. ANY PIECE OF EQUIPMENT PLACED ON THE JOB WITHOUT PRIOR APPROVAL WILL BE SUBJECT TO REMOVAL AT THE SOLE EXPENSE OF THE CONTRACTOR. B. SUBMITTALS ARE FOR INFORMATION AND COORDINATION ONLY. REVIEW OF MATERIAL AND/OR EQUIPMENT SUBMITTALS SHALL IN NO WAY RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO COMPLY WITH PLANS AND SPECIFICATIONS REQUIREMENTS. POINTS OF NON-COMPLIANCE WHICH ARE NOT NOTED SHALL NOT BE CONSTRUED TO BE AN APPROVAL OF THE NON-COMPLIANCE. SUBMITTALS SHALL CLEARLY STATE WHERE EQUIPMENT DOES NOT AGREE WITH THE CONTRACT DOCUMENTS. C. SUBMITTALS SHALL INCLUDE MANUFACTURER'S SPECIFICATIONS, PHYSICAL DIMENSIONS, WEIGHTS AND RATINGS OF EQUIPMENT SUBMITTED. INDICATE EQUIPMENT LAYOUTS, ELECTRICAL CHARACTERISTICS, WIRING AND CONTROL DIAGRAMS, SIZES AND LOCATIONS OF PIPING, DUCT, CONDUITS, AND OTHER CONNECTION SIZES AND LOCATIONS. 2. SHOP DRAWINGS: CONTRACTOR SHALL PREPARE AND SUBMIT DETAILED 1/4"=1'-0" SCALE DRAWINGS THAT HAVE BEEN PROPERLY COORDINATED WITH OTHER TRADES. INDICATE LOCATION AND SIZES OF ACCESS PANELS IN HARD CEILINGS FOR EQUIPMENT AND DAMPER ACCESS. 3. AS BUILT DRAWINGS: MAINTAIN ACCURATE RECORDS OF ANY CHANGES FROM THE CONTRACT DOCUMENTS AND SHOP DRAWINGS. UPON COMPLETION OF THE PROJECT, DELIVER TO THE ENGINEER ONE (1) SET OF LEGIBLE REPRODUCIBLES AND (3) BLUELINE SETS OF THESE RECORD DRAWINGS. 4. WARRANTY: UNLESS SPECIFIED OTHERWISE BY ARCHITECT, ENGINEER, OWNER OR OWNER'S REPRESENTATIVE, UPON COMPLETION OF THE PROJECT, DELIVER TO THE OWNER A WRITTEN ONE (1) YEAR WARRANTY ON THE SYSTEMS, MATERIALS AND ALL WORK PERFORMED. THIS INCLUDES THE ENTIRE COST, INCLUDING MATERIALS AND/OR LABOR, OF CORRECTIVE WORK REQUIRED AND NECESSITATED BY DEFECTS IN MATERIALS AND/OR WORKMANSHIP. CONTRACTOR SHALL ALSO PRESENT THE OWNER WITH A COPY OF ALL MANUFACTURER'S WARRANTIES THAT EXCEED THE WARRANTY PERIOD, SUCH AS AC UNIT COMPRESSORS. 5. OPERATION AND MAINTENANCE INSTRUCTIONS: UPON THE COMPLETION OF THE PROJECT, DELIVER TO THE OWNER THE REQUIRED NUMBER OF COPIES OF HARD BOUND 0 & M MANUALS. INCLUDE IN THE MANUAL INSTRUCTIONS PREPARED SPECIFICALLY FOR THE SYSTEMS PROVIDED, ALONG WITH DESCRIPTIONS, PARTS LIST, INSTRUCTIONS, AND WARRANTIES. START-UP REPORTS FOR ALL EQUIPMENT WILL BE DELIVERED WITH THE MATERIALS AND EQUIPMENT UTILIZED IN THE PROJECT. IDENTIFY EACH ITEM BY THE DESIGNATION APPEARING ON THE DRAWINGS. 6. OWNER TRAINING: AT A TIME DESIGNATED BY THE OWNER, PROVIDE A SUITABLE TECHNICIAN, MECHANIC OR ENGINEER TO REVIEW THE SYSTEMS WITH OWNER'S REPRESENTATIVE TO THOROUGHLY FAMILIARIZE HIM WITH THE OPERATIONS AND MAINTENANCE OF THE SYSTEMS. UP TO (8) EIGHT HOURS TOTAL TRAINING TIME SHALL BE REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. PRIOR TO TRAINING THE OWNER SHALL HAVE TAKEN POSSESSION OF THE 0 & M MANUALS, AND SHALL HAVE HAD A REASONABLE AMOUNT OF TIME FOR THE PERSONNEL TO FAMILIARIZE THEMSELVES WITH THE CONTENTS OF THE MANUALS. PART II - PRODUCTS A. GENERAL PRODUCTS 1. SEISMIC RESTRAINTS: A. WHERE REQUIRED BY THE BUILDING OFFICIALS/BUILDING CODES, FURNISH AND INSTALL SEISMIC RESTRAINTS FOR DUCTWORK, PIPING, AND EQUIPMENT. SEISMIC RESTRAINTS SHALL BE DESIGNED TO RESIST SEISMIC FORCES PRESCRIBED IN THE BUILDING CODES FOR THE PROJECT LOCATION. B. WHERE REQUIRED BY THE BUILDING OFFICIAL, PROVIDE STRUCTURAL CALCULATIONS SEALED AND SIGNED BY A LICENSED STRUCTURAL ENGINEER. C. REFERENCE THE LATEST EDITION OF THE SMACNA SEISMIC RESTRAINT MANUAL FOR GUIDELINES. 2. FURNISH AND INSTALL NEW PRODUCTS OF ESTABLISHED AND REPUTABLE MANUFACTURERS. SEE LIST OF ACCEPTABLE MANUFACTURERS ELSEWHERE IN THESE SPECIFICATIONS. MAKE NO EQUIPMENT SUBSTITUTIONS THAT WOULD LEAVE INADEQUATE OPERATING OR SERVICING SPACE. REFER TO 'SUBSTITUTIONS' SECTION OF THE SPECIFICATION. 3. ACCESSORIES REQUIRED FOR PROPER OPERATION OF THE SYSTEMS, EVEN THOUGH NOT SPECIFICALLY INDICATED, SHALL BE INCLUDED AND INSTALLED. SUCH ACCESSORIES MAY INCLUDE, BUT ARE NOT LIMITED TO, FILTERS, CONDENSATE DRAINS, RELIEF VALVES, SERVICE VALVES, THERMOSTATS, VIBRATION ISOLATORS, ETC. MOTOR STARTERS FOR PREWIRED EQUIPMENT AND OTHER PROTECTION AND CONTROL DEVICES ARE TO BE FURNISHED UNDER THE MECHANICAL CONTRACTOR'S SCOPE OF WORK. STARTERS FOR NON-PREWIRED EQUIPMENT, I.E., FANS, PUMPS ETC., ARE UNDER THE ELECTRICAL CONTRACTOR'S SCOPE OF WORK, UNLESS NOTED OTHERWISE. 4. SPECIFIC REFERENCE TO A MANUFACTURER'S PRODUCT IS ONLY TO ESTABLISH TYPE, QUALITY, AND PERFORMANCE REQUIRED. THESE QUALIFICATIONS ARE IN ADDITION TO THE REQUIREMENTS SHOWN ON THE PLANS AND ELSEWHERE IN THESE SPECIFICATIONS. LISTING OF ALTERNATE EQUIPMENT MANUFACTURERS SHALL NOT BE CONSTRUED AS AN UNCONDITIONAL APPROVAL OF THE PRODUCTS OF THOSE MANUFACTURERS. B. AIR CONDITIONING UNITS 1. FURNISH AND INSTALL HEATING/COOLING UNITS WITH CAPACITIES AS SCHEDULED. UNITS SHALL BE COMPLETE WITH HERMETICALLY SEALED COMPRESSOR WITH HIGH AND LOW PRESSURE CUT-OFFS, COILS, HEATING SECTION, BLOWERS, NECESSARY REFRIGERANT PIPING, INSULATED COMPRESSOR COMPARTMENT, AIR COOLED CONDENSER, CONDENSER BLOWER OR FAN, AUTOMATIC CONTROLS, CONTROL PANEL WITH STARTERS, RELAYS, ETC. FOR SINGLE POINT POWER CONNECTION, WITHIN A WEATHERPROOF, INSULATED DECORATIVE CASING. UNITS SHALL BE FURNISHED WITH (1) ONE CONSTRUCTION SET OF FILTERS, INSTALLED PRIOR TO START-UP. REPLACE FILTERS AT SUBSTANTIAL COMPLETION BEFORE TEST AND BALANCE ACTIVITIES COMMENCE. FURNISH ONE COMPLETE SET OF SPARE FILTERS TO OWNER. FURNISH ONE COMPLETE SET OF BELTS. 2. UNITS SHALL BE COMPLETELY FACTORY WIRED FOR TERMINAL CONNECTIONS OF THERMOSTAT WITH A FAN-AUTO/MANUAL SWITCH AND A SYSTEM HEAT/OFF/COOL/AUTO SWITCH. UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS, COMPLETE WITH ALL SCHEDULED AND NECESSARY ACCESSORIES FOR EFFICIENT AND PROPER OPERATION. C. EXHAUST FAN AND VENT UNITS 1. FURNISH AND INSTALL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUST FANS WITH CAPACITIES AS SCHEDULED. UNITS SHALL BE COMPLETE WITH ALUMINUM HOUSING, BACKWARD INCLINED WHEEL, ALUMINUM CURB CAP WITH PREPUNCHED MOUNTING HOLES, BIRDSCREEN, BALL BEARING MOTORS, SLEEVE BEARING MOTORS, MOTOR ISOLATED ON SHOCK MOUNTS, CORROSION RESISTANT FASTENERS, ETC. C. EXHAUST FAN AND VENT UNITS (CONT'D.) 2. FURNISH AND INSTALL BELT DRIVE UPBLAST CENTRIFUGAL ROOF EXHAUST FANS WITH CAPACITIES AS SCHEDULED. UNITS SHALL BE COMPLETE WITH ALUMINUM HOUSING, BACKWARD NCLINED ALUMINUM WHEEL, MOTOR AND DRIVES ISOLATED ON SHOCK MOUNTS, DRAIN TROUGH, ADJUSTABLE MOTOR PULLEY, ADJUSTABLE MOTOR PLATE, FAN SHAFT MOUNTED IN BALL BEARING PILLOW BLOCKS, BEARINGS THAT MEET OR EXCEED TEMPERATURE RATING OF FAN, STATIC RESISTANT BELTS, CURB CAP WITH PREPUNCHED MOUNTING HOLES, BALL BEARINGMOTORS, CORROSION RESISTANT FASTENERS, ETC. 3. UNITS SHALL BE COMPLETELY FACTORY WIRED AND INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS, COMPLETE WITH ALL SCHEDULED AND NESESSARY ACCESSORIES FOR EFFICIENT AND PROPER OPERATION. D. DUCTWORK 1. PROVIDE A COMPLETE SYSTEM OF DUCTWORK FABRICATED AND INSTALLED IN STRCT ACCORDANCE WITH LATEST VERSIONS OF THE ASHRAE FUNDAMENTALS HANDBOOK AND SMACNA DUCT CONSTRUCTION STANDARDS. DUCT SYSTEM SHALL BE CONSTRUCTED AS REPRESENTED ON THESE DRAWINGS AND AS COORDINATED IN DETAIL ON THE APPROVED DUCTWORK SHOP DRAWINGS. IF ADDITIONAL CHANGES IN DUCT ARRANGEMENT OR IN DUCT SIZES ARE REQUIRED, THEY SHALL BE MADE ONLY AFTER WRITTEN APPROVAL IS OBTAINED FROM THE ENGINEER. 2. MAIN AND BRANCH DUCTS SHALL BE RECTANGULAR, ROUND, OR FLAT -OVAL, AND SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL UNLESS NOTED OTHERWISE. DUCT SEES SHOWN ON THE DRAWINGS ARE NET OPENINGS AND SHALL BE INCREASED TO ACCOMMODATE DUCT LINING WHERE APPLICABLE. 3. FLEXIBLE DUCT SHOWN AT CONNECTION TO AIR DISTRIBUTION DEVICES SHALL BE A FABRICATED ASSEMBLY WITH AN ACOUSTICALLY -RATED CORE CONSISTING OF AN INNER SLEEVE, 2-INCH THICK FIBERGLASS INSULATION, WITH AN R-6.0 MINIMUM AND AN OUTER VAPOR BARRIER COVERING EQUAL TO THERMAFLEX M-KE. 4. WHETHER SHOWN ON PLANS OR NOT, PROVIDE MANUAL VOLUME DAMPERS IN EACH RUNOUT TO EACH SUPPLY DIFFUSER OR REGISTER, RETURN AND EXHAUST GRILLE AND ALSO AS REQUIRED FOR A PROPERLY BALANCED SYSTEM. PROVIDE ACCESS PANELS TO DAMPERS LOCATED ABOVE HARD CEILINGS. 5. VOLUME DAMPERS FOR RECTANGULAR DUCTS SHALL BE CONSTRUCTED OF 16 GAUGE GALVANIZED STEEL, BE OF THE OPPOSED BLADE TYPE AND BE FURNISHED WITH LOCKING AND INDICATING QUADRANTS. DAMPERS FOR ROUND DUCTS SHALL BE SINGLE -BLADE TYPE UP TO 30"0. USE CONTINUOUS ROD ON 2" W.G. CLASS DAMPERS FROM 12"0-28"0, AND RECTANGULAR DUCTS FROM 18"-48" WIDE. 6. ROUND TAPS FOR FACTORY -MADE AIR DUCTS IN SECTIONS OF ROUND SHEET METAL DUCTS SHALL BE MADE WITH ANY OF THE FITTINGS LISTED BELOW: A. CONICAL TEE. B. CONICAL SADDLE TAP. C. ELBOW (IF LAST FITTING). D. 45° TEE OR SADDLE TAP. ROUND TAPS FOR FACTORY -MADE AIR DUCTS IN SECTIONS OF RECTANGULAR SHEET METAL DUCTS SHALL BE MADE WITH ANY OF THE FITTINGS LISTED BELOW: A. COLLAR (CONICAL). B. COLLAR (STRAIGHT, ONLY WHEN SHOWN ON DRAWINGS). 8. DOVETAILED CUTOFFS ARE NOT ACCEPTABLE. DUCT TAPE OR OTHER PRESSURE SENSITIVE TAPES ARE NOT ACCEPTABLE. 9. TAPS IN SECTIONS OF ROUND FACTORY -MADE FLEXIBLE AIR DUCTS (WHEN ALLOWED) SHALL BE MADE BY INSERTING, IN THE FLEXIBLE DUCT SECTION, ANY OF THE SHEET METAL FITTINGS LISTED BELOW: A. 90 DEGREE CONICAL STRAIGHT TEE. B. 45 DEGREE STRAIGHT LATERAL. C. 45 DEGREE STRAIGHT LATERAL WITH 45 DEGREE ELBOW. D. 45 DEGREE STRAIGHT LATERAL CROSS. E. Y BRANCH WITH 45 DEGREE ELBOW. E. DUCT INSULATION 1. THERMAL INSULATION: A. CONCEALED SUPPLY DUCTS AND RETURN DUCTS ABOVE CEILING OR IN FURRED SPACES SHALL BE THERMALLY INSULATED. B. THERMAL INSULATION SHALL BE FLEXIBLE BLANKET GLASS FIBER INSULATION WI1H FACTORY APPLIED FLAME RETARDANT, FOIL-SCRIM-KRAFT VAPOR BARRIER (FSK), MAXIMUM K OF 0.30 AT 75 DEGREES F MEAN TEMPERATURE MINIMUM .75 POUND DENSITY. INSULATION SHALL BE 2" THICK. C. INSULATION SHALL BE APPLIED OVER SURFACES WHICH HAVE BEEN WIPED CLEAN AND DRY AND SHALL HAVE 3-INCH MINIMUM OVERLAP ON BOTH LONGITUDINAL AND TRANSVERSE SEAMS. D. SUPPLY AND RETURN DUCTS LOCATED OUTSIDE SHALL BE LINED WITH 2" ACOUSTICAL LINER AND SEALED WATER TIGHT, OR INSULATED EXTERNALLY WITH 2" RIGID BOARD AND ALUMINUM LAGGING SEALED WATER TIGHT. F. AIR FILTERS 1. REPLACEABLE (THROWAWAY) PANEL FILTERS: A. PROVIDE FACTORY -FABRICATED, VISCOUS -COATED, FLAT PANEL TYPE REPLACEABLE AIR FILTERS WITH HOLDING FRAMES AS INDICATED, IN SIZES I INDICATED, WITH 2" THCK UL CLASS 2 THROWAWAY MEDIA MATERIAL, CONSTRUCT MEDIA OF INTERLACED GLASS FIBERS, SPRAY WITH NON-FLAMMABLE ADHESIVE, FRAME IN THROWAWAY FIBERBOARD CASINGS, AND SANDWICH BETWEEN PERFORATED METAL GRILLES. B. CONSTRUCT DUCTWORK -HOLDING FRAMES OF 20-GA. GALVANIZED STEEL, CAPABLE OF HOLDING MEDIA AND MEDIA FRAME IN PLACE, AND GASKETED TO PREVENT UNFILTERED AIR BY-PASSING BETWEEN MEDIA FRAMES AND HOLDING MEMBERS. C. PROVIDE FILTERS WITH RATED FACE VELOCITY OF 500 FPM, INITIAL RESISTANCE OF OT GREATER THAN 0.30" W.G., FINAL RATED RESISTANCE OF 0.50" W.G., AND AVERAGE ARRESTANCE OF 80%. G. VARIABLE FREQUENCY DRIVES 1. PROVIDE SOLID STATE FREQUENCY DRIVES (VFD) TO CONVERT 460 VOLT, 3 PHASE, 60 Hz POWER TO ADJUSTABLE VOLTAGE AND FREQUENCY, 3 PHASE , AC POWER FOR STEPLESS MOTOR CONTROL FROM 10% TO 110% OF BASE SPEED. 2. THE VFD SHALL BE OF VARIABLE TORQUE DESIGN AND SHALL MATCH MOTOR CHARACTERISTICS. 3. THE VFD SHALL UTILIZE DIGITAL 6 (MIN.) PULSE WIDTH MODULATION USING INTEGRATED GATE BIPOLAR TRANSISTORS (IGBT) FOR SPEED CONTROL. THE HORSE POWER OF MOTORS ARE AS INDICATED ON DRAWINGS. THE VFD MIN. EFFICIENCY AT FULL LOAD SHALL BE NO LESS THAN 95 PERCENT. POWER FACTOR SHALL BE 0.95 LAGGING (MIN.), OVER THE ENTIRE OPERATING RANGE MEASURED AT THE INPUT TO THE VFD. 4. THE VFD SHALL NOT INDUCE EXCESSIVE LOSSES INTO THE MOTOR. WORST CASE MOTOR LINE CURRENT SHALL NOT EXCEED 1.05 TIMES THE RATED RMS MOTOR CURRENT FOR A SINE WAVE OPERATION AT RATED SPEED, TORQUE AND VOLTAGE. G. VARIABLE FREQUENCY DRIVES (CONT'D.) 5. PROTECTIVE CIRCUITS AND FEATURES: PROVIDE INSTANTANEOUS ELECTRONIC TRIP (IET) FOR FOLLOWING FAULT CONDITIONS: A. B. C. D. E. F. G. H. J. K. L. M. 110% OF DRIVE'S MAXIMUM SINE WAVE CURRENT RATING IS EXCEEDED. OUTPUT PHASE TO GROUND SHORT CIRCUIT CONDITIONS. OUTPUT PHASE TO PHASE SHORT CIRCUIT CONDITION. HIGH OR LOW INPUT LINE VOLTAGE. EXTERNAL FAULT. THIS PROTECTIVE CIRCUIT SHALL PERMIT WIRING OF REMOTE NC SAFETY CONTACTS SUCH AS HIGH STATIC, FIRESTAT, ETC. TO SHUT DOWN THE DRIVE. INVERTER OVER TEMPERATURE PROTECTION. MOTOR OVERLOAD PROTECTION. VFD SHALL BE SENSITIVE TO INCOMING POWER PHASE SEQUENCE. VFD SHALL HAVE DC BUS DISCHARGE CIRCUIT WITH INDICATING LAMP. VFD SHALL HAVE LOSS OF PHASE PROTECTION. VFD SHALL HAVE INPUT TRANSIENT PROTECTION BY MEANS OF SURGE SUPPRESSION. INVERTER OVERCURRENT TRIP. INVERTER OVERLOAD TRIP. 6. EQUIP VFD WITH METERS OR DIGITAL READOUT DEVICES/SELECTOR SWITCH, FLUSH MOUNTED IN THE CONTROLLER DOOR AND CONNECTED TO INDICATE THE FOLLOWING CONTROL PARAMETERS: A. B. C. D. E. F. OUTPUT FREQUENCY (Hz). MOTOR SPEED (RPM). MOTOR STATUS (RUN, STOP, FAULT). MOTOR CURRENT (AMPERES). SET -POINT FREQUENCY (HZ). MOTOR OUTPUT VOLTAGE. 7. ADDITIONAL FEATURES: A. INPUT DISCONNECT: PROVIDE LOAD -BREAK FUSED SWITCH OR THERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKER, AND MOUNT INSIDE THE VFD ENCLOSURE. B. MOTOR OVERLOAD: PROVIDE THERMAL OVERLOAD RELAY TO PROTECT MOTOR. C. SPEED CONTROL: THE SPEED CONTROL SIGNAL TO VFD SHALL BE 3-15 PSI. D. CONTROL TRANSFORMER: PROVIDE A 480-120 VOLT CONTROL TRANSFORMER IN EACH INDIVIDUAL VFD UNIT. E. MANUAL BYPASS WITH MAGNETIC CONTACTORS: MANUAL BYPASS SHALL PROVIDE ALL THE CIRCUITRY NECESSARY TO SAFELY TRANSFER THE MOTOR FROM THE VFD TO THE POWER LINE, OR FROM THE LINE TO THE DRIVE WHILE THE MOTOR IS AT ZERO SPEED. F. OUTPUT SIGNAL INTERFACE: PROVIDE AT LEAST ONE ANALOG OUTPUT SIGNAL (4-20 MA), WHICH CAN BE PROGRAMMED FOR: OUTPUT FREQUENCY (Hz). OUTPUT CURRENT. MOTOR TORQUE (PERCENT). MOTOR SPEED (RPM). SET -POINT FREQUENCY (HZ). DC -LINK VOLTAGE. G. COMMUNICATIONS: PROVIDE AN RS-485 INTERFACE, TO PERMIT THE VFD TO BE USED WITH AN EXTERNAL COMMUNICATION SYSTEM. THE INTERFACE SHALL ALLOW ALL PARAMETER SETTINGS TO BE PROGRAMMED VIA THE BUILDING MANAGEMENT SYSTEM. PROVIDE CAPABILITY FOR THE VFD TO RETAIN PROGRAMMED SETTINGS IN NONVOLATILE MEMORY. H. PLUG-IN TESTER CARD: PROVIDE PLUG-IN TESTER CARD FOR MONITORING DIFFERENT SIGNALS WITHIN VFD FOR START-UP AND TROUBLESHOOTING. ONE TESTER SHALL FIT ALL VFD UNITS. F. LIST OF ACCEPTABLE MANUFACTURERS 1. FOLLOWING IS A LIST OF MANUFACTURES WHOSE EQUIPMENT IS ACCEPTABLE AS TO MANUFACTURE, SUBJECT TO CONFORMANCE WITH THE DRAWINGS AND SPECIFICATIONS. CAREFUL CHECKING MUST BE MADE TO VERIFY THAT EQUIPMENT WILL MEET CAPACITIES, REQUIREMENTS, SPACE AND WEIGHT ALLOCATIONS. A. B. C. D. E. F. G. H. J. HVAC PACKAGED EQUIPMENT: CARRIER OR APPROVED EQUAL BY ARCHITECT/ENGINEER FANS: GREENHECK, COOK, ACME, PENN, PRICE AIR DEVICES: TITUS, KREUGER, METAL-AIRE, PRICE INSULATION: CERTAINTEED, OWENS-CORNING, MANVILLE, KNAUF UNIT HEATERS: CHROMOLOX, REZNOR, Q-MARK, MARKEL DUCT SEALANT: DESIGN POLYMERICS, MCGILL AIRFLOW, CANVAS TAPE AND ARABOL VARIABLE FREQUENCY DRIVE: ALLEN-BRADLEY, ASEA BROWN BOVERI (ABB), CUTLER -HAMMER, SQUARE D, TOSHIBA. SPRING ISOLATION RAILS: MICRO -METAL. SPLIT SYSTEM HEAT PUMP UNITS: CARRIER, TRANE, SANYO AIR FILTERS: AFF, FARR OR FLANDERS. 2. APPROVAL FOR SUBSTITUTIONS MUST BE MADE IN ACCORDANCE WITH PART 1, SECTION G "SUBSTITUTIONS" OF THESE SPECIFICATIONS. PART III - EXECUTION A. GENERAL 1. INSTALL MATERIALS AND EQUIPMENT IN AN ARRANGEMENT THAT WILL GIVE THE GREATEST PRACTICAL EASE OF OPERATION AND SERVICE TO THE OWNER. 2. INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES. 3. PERFORM WORK IN ACCORDANCE WITH THE BEST TRADE PRACTICES. INSTALL MATERIALS AND EQUIPMENT SQUARELY WITH THE BUILDING LINES. PROVIDE RIGID PERMANENT BASES AND SUPPORTS FOR WORK. 4. CONSTRUCT AND BRACE EQUIPMENT, PIPING, ETC., SO THAT THERE WILL BE NO VIBRATION AND/OR RATTLING WHEN THE SYSTEM IS IN OPERATION. 5. COVER AND PROTECT EQUIPMENT AND MATERIALS FROM WEATHER, THEFT, ETC., UNTIL DATE OF COMPLETION. PLUG AND/OR CAP OPEN ENDS OF INSTALLED PIPING AND/OR DUCTWORK PENDING EXTENSION OR FINAL CONNECTION. B. DUCTWORK 1. CONSTRUCT DUCTWORK WITH MATERIAL, GAUGES, JOINTS, BRACING AND SUPPORTS IN ACCORDANCE WITH LATEST SMACNA STANDARDS. 2. DUCTWORK SHALL BE RIGIDLY CONSTRUCTED AND SUBSTANTIALLY AIR -TIGHT. SEAL ALL DUCTWORK WITH A WATER BASED DUCT SEALANT (DESIGN POLYMERICS DP-1010 OR EQUAL) OR ARABOL AND CANVAS TAPE. DO NOT UTILIZE PRESSURE SENSITIVE TAPES. SEAL DUCTWORK IN ACCORDANCE WITH TABLE 4-1 "APPLICABLE LEAKAGE CLASSES" OF THE LATEST SMACNA HVAC LEAKAGE TEST MANUAL. 3. MAKE CONNECTIONS BETWEEN FLEXIBLE DUCTS AND RIGID TRUNK DUCTS WITH FACTORY FABRICATED FITTINGS WITH DAMPER. SECURE FLEX DUCT TO FITTING WITH CLAMPS OR PANDUIT STRAPS INSTALLED TO FACTORY RECOMMENDED TENSION. INSTALL CLAMPS ON LINER AND SECOND CLAMP OVER JACKET. JOB INSPECTION MAY REQUIRE REMOVAL AND REPLACEMENT OF A RANDOM SAMPLING OF CONNECTIONS. 4. ELBOWS - O S SHALL HAVE A THROAT RADIUS EQUAL TO 1 1 /2 TIMES THE DUCT WIDTH. SQUARE ELBOWS SHALL HAVE TURNING VANES OR SPLITTER. TRANSITIONS SHALL NOT EXCEED 4 TO 1 ASPECT RATIO. C. AUTOMATIC TEMPERATURE CONTROLS & AUTOMATIC SHUT-OFF ROOFTOP AC UNITS SHALL BE TURNED ON/OFF WITH PROGRAMMABLE 7-DAY THERMOSTATS. THERMOSTATS SHALL BE SET FOR CONTINUOUS FAN OPERATION. 2. EXHAUST FANS ARE CONTROLLED AS SPECIFIED IN THE EXHAUST FAN SCHEDULE. 3. AIR CONDITIONING UNITS SHALL BE EQUIPPED WITH IONIZATION TYPE DUCT DETECTOR, UNLESS INDICATED OTHERWISE. 4. DUCT SMOKE DETECTOR SHALL BE LOCATED IN THE MAIN SUPPLY AND RETURN - AIR DUCT AHEAD OF ANY BRANCH TAKE -OFFS, AND INSTALLED PER MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. 5. WHERE REQUIRED BY BUILDING OFFICIALS, ACTIVATION OF ANY SMOKE DETECTOR SHALL CAUSE THE AIR -MOVING EQUIPMENT TO AUTOMATICALLY SHUT DOWN. WHERE A SYSTEM CONSISTS OF MORE THAN ONE AIR CONDITIONER, ACTIVATION OF ANY OF THE SMOKE DETECTORS IN ANY OF THE AIR CONDITIONERS SERVING THE COMMON AREA SHALL CAUSE ALL AIR -MOVING EQUIPMENT SERVING THAT COMMON AREA TO SHUT DOWN. 6. WIRING OF THE SMOKE DETECTORS SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR AND SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE NEC AND ELECTRICAL SECTIONS OF THE SPECIFICATION. 7. FIRE ALARM CONTRACTOR SHALL CONNECT ALL FIRE/SMOKE DAMPERS TO THE FIRE CONTROL SYSTEM, AS REQUIRED BY LOCAL BUILDING AUTHORITY. THE FIRE ALARM CONTRACTOR SHALL PROVIDE AND INSTALL THE CEILING MOUNTED SMOKE DETECTOR STATUS LIGHTS. D. TESTING AND BALANCING OF AIR AND WATER 1. OBTAIN THE SERVICES OF AN INDEPENDENT TEST AND BALANCE AGENCY THAT SPECIALIZES IN AND WHOSE BUSINESS IS LIMITED TO THE TESTING AND BALANCING OF AIR CONDITION SUSTEMS. 2. THE AGENCY SELECTED SHALL BE A FULLY CERTIFIED MEMBER OF THE AABC. AT LEAST ONE MEMBER OF THE AGENCY SHALL BE QUALIFIED AS A CERTIFIED TEST AND BALANCE ENGINEER BY THE NATIONAL EXAMINING BOARD. ALL FINAL REPORTS SHALL BE SIGNED BY THIS CERTIFIED TEST AND BALANCE ENGINEER AND SHALL INCLUDE HIS OFFICIAL STAMP. 3. TESTING AND BALANCING SHALL BE PERFORMED IN COMPLETE ACCORDANCE WITH AABC STANDARDS FOR FIELD MEASUREMENT AND INSTRUMENTATION. TESTING AND BALANCING SHALL BE PERFORMED ON ALL SYSTEMS. 4. INSTRUMENTS USED FOR TESTING AND BALANCING OF SYSTEMS MUST HAVE BEEN CALIBRATED WITHIN PERIOD OF SIX MONTHS AND BEEN CHECKED FOR ACCURACY PRIOR TPO START OF WORK. 5. MEASURE AND BALANCE MAXIMUM WATER FLOW QUANTITY AT CLOSED LOOP SYSTEM. SET BALANCING VALVES AND LOCK INTO PLACE. 5. MEASURE AND BALANCE THE SUPPLY FAN AIR FLOW TO THE REQUIRED AIR QUANTITY, INCLUDING MOTOR DRIVE INCLUDING RETURN, EXHAUST AND MAKE-UP AIR FLOWS. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 08 2015 City of Tukwila BUILDING' DIVISION RECEIVED CITY OF TUKWILA JAN 0 6 2015 M!CF: ■ Town PLIJ PG ROU P ARCHITECTURE & ENGINEERING a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.plumpgroup.com STAMP EXPIRES 03-19-16 PROJECT NAME/ADDRESS: GRILL CITY & CRISPY TOWN SUITE 140 & SUITE 110 SEAFOOD CITY SUPER MARKET 1368 SOUTHCENTER MALL, TUKWILA, WA 98188 REVISIONS: 11)>1[›11›11.1e>li›.r> ISSUE DATE: 1ST ................ 2ND 3RD 4TH 5TH 6TH JOB NUMBER PROJECT*: 141112 DRAWN BY SHEET CONTENT MECHANICAL SPECIFICATIONS SHEET NO -4.0