PLUMBING/GAS PIPING PERMIT
Permit Number: PG14-0007
Issue Date: 2/7/2014
Permit Expires On: 8/6/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
COSTCO WHOLESALE CORPORATIO
999 LAKE DR PROPERTY TAX DEPT
006, ISSAQUAH, WA, 98027
ALLEN TURNER
19430 68 AVE S , KENT, WA, 98032
KEY MECH CO OF WASHINGTON
Address: 19430 68 AV S, SUITE B , KENT, WA,
98032
License No: KEYMEW*240NZ
Lender:
Name:
Address:
Phone: (253) 872-7392
Phone: (253) 872-7392
Expiration Date: 4/1/2015
DESCRIPTION OF WORK:
TIE INTO EXISTING 1 1/2" CAPPED GAS LINE
Valuation of Work: $1,826.00
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Fees Collected: $126.76
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Permit Center Authorized Signature:
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: Date: 2 /1/ ( 4
Print Name: L\c.1.- .V4 11 Lt►2r.►�t�,
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving
notification that the work is ready for inspection.
7: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
8: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be
protected in accordance with the requirements of the building code.
9: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any
other ordinance of the jurisdiction.
10: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this
permit.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
9002 ROUGH -IN GAS PIPING
CITY OF TUKt "A
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
littp://www.TukwilaWA.gov
Plumbing/Gas Permit No. ` DO M
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 4 Ga s'TGa b ‘2 I \/
King Co Assessor's Tax No.: 9'2"*.=)4"toc.,. 3a5
Tenant Name: G44TGa \\/Neie)IZ 9
PROPERTY OWNER
Name: b S_'Ga \V i4 o t-.EQI._.F-
Address: gelq L.Av_e_ t7lz lye.
City: LAAIA State: \VQ Zip
002,
CONTACT PERSON — person receiving all project
communication
Name: A 1...IeU.S `C't.t 1210.1E12
Address:
IA430 -66AJ,
City: t-V-T State: \va 4003Z
Phon 5, _viz -i3g2 F 53-g-12. 73�8
Emaila±tA li, n re ICIc`(WIEG4.4t41 LAL . GoM
Suite Number:
Floor: 1
New Tenant: ❑ Yes No
PLUMBING CONTRACTOR INFORMATION
Company Name: te_ta....( *.,‘ %�04 43.4t.d1....
Address: (q 4 30 - Co� 'L Avm • S •
City:1L..el.4`j' State: \vim Zi.so32
Phones Fax
Q-p�,Tr2-'13G8
gg,67z...73ct2
Ic rvl a \ 24OIrl7 Expo/ `:124.15
Tukwila Business License N
-LA-1
G�t...1.- �� • 3�t �- 301
Valuation of Project (contractor's bid price): $ I( e...) Z.& ./
�
l
Scope of Work (please provide detailed information): 1' I � 1 h1T0 I - t ST 1 (Z 4..a1P 9tE rD 44.S
k_ 1 c t \s.J Ta P a
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
ktIr)-) OVA
Page 1 of 2
Indicate type of plumbing fixtures and/or piping outlets being installed and the quantit} ow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
I
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value •of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING MTIOR ED AGENT:
Signature:
Print Name: A •
Mailing Address: Ia '4 3 6 - Lg.) 4.1E. 4,
Date: I f% f (A -
Day Telephone: 2 5'3 - 53/ x - -j 5et
ke.v4T \\/4. 3 7
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
I PAID
$126.76
PG14-0007 Address: 400 COSTCO DR
Apn: 2523049063
$126.76
GAS
$121.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
$24.38
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R968
R000.322.900.04.00
$4.88
$126.76
Date Paid: Tuesday, January 28, 2014
Paid By: KEY MECHANICAL CO. OF WASHINGT
Pay Method: CHECK 2552
Printed: Tuesday, January 28, 2014 12:47 PM 1 of 1
CRWSYSTEMS
INSPECTION RECORD
Retain a copy with permit 1'497
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project;,
t'rSTa
Type of Inspection:
FtN4C 6AsetPL.
Date Called:
Address:
Special Instructions:,
Date Wanted:
.
Requester:
Phone No:
®Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
REI1 SPECTION FEE REQUIR . Prior ton xt inspection, fee/must be
aid at 6300 Southcenter Blvd. Suite 100. C ll to schedule reinspection.
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0007
PROJECT NAME: COSTCO
DATE: 01/28/2014
SITE ADDRESS: 400 COSTCO DR
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Pf1N( O 2-0
S 9
Building Division
Public Works
n
Fire Prevention
Structural
n
Planning Division n
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 01/30/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
DUE DATE: 02/27/14
Approved with Conditions l'Rk
Denied
(ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire D Ping ❑ PW ❑ Staff Initials:
12/18/2013
KEY MECH CO OF WASHINGTO1' "
Page 1 of 3
Washington State Department of
Labor & Industries
KEY MECH CO OF WASHINGTON
Owner or tradesperson
HEISLER, ROBERT L
Principals
HEISLER, ROBERT L
FRANK LEONARD
LEE SANDAHL
Doing business as
KEY MECH CO OF WASHINGTON
WA UBI No.
600 196 154
19430 68TH AVE S STE B
KENT, WA98032
253-872-7392
KING, County
Business type
Corporation
Governing persons
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
KEYMEW*240NZ
Effective — expiration
08/09/1976 — 04/01/2015
Bond
LIBERTY MUTUAL INS CO
Bond account no.
023011682
Received by L&I
03/23/2009
Active.
Meets current requirements.
$12,000.00
Effective date
04/01/2009
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600196154&LIC=KEYMEW*240NZ&SAW= 02/07/2014
G\Users\mariag\appdata\locat\temp\AcPublish_3024\COS-TUKVILA-S1-HVAC ROOF FRAMING PLAN-192-87022029,dwg, 11-26-13, 1t59pm, Mariag, 192
REVISIONS ""1
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fe
F FRAMING PLAN
NOTES:
1.) ALL ITEMS ARE EXISTING (E) UNLESS NOTED AS NEW(N).
2.) FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
NOTIFY ENW IF EXISTING DIMENSIONS AND EXISTING CONDITIONS ARE NOT AS SHOWN
ON PLANS AND SECTIONS.
1/16" = 1'-0"
500'-0"
EPA ATE FERMI
REQ IRED FOR
htmbinq
❑ as Pipng
Ci of Tukwila
BUILD 11G DIVISIO
STING ' LB GI' PERS,
E ISTING ONCR•TE
WLLS B OW, P.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
City of Tukwila
BUILDING DIVISION
FI! Cop,
Permit No. _ �W I �-`DOD'
Plan review
Approval of
the v olation
of approved
ey
approval is subject to errors and omission%
construction documents doe
of any adopted code or ordinan ..
Field Copy end conditions is.acknowlel g
Data
2 /1 / 4
Oty Of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JAN282014
PERMIT CENTER
co
0
rn
co
7
0001
U
0
w
0
DRAWING REVISIONS
DRAWING SUBMITTALS
SUBMIT F'OR PERMIT
SUBMIT FOR BID
SUBMIT FOR CONSTRUCTION
w
0
DRAWING REVISIONS
ci
z
ROOF FRAMING PLAN
z
w
2 0
CO U
JOB NO:
87022029
ENGINEER:
W. CHEN
DRAWN:
M. GARCINI
DATE:
11-25-13
SHEET NO:
S 1
U\_pre88\87022\87022029\COS-TUKWILA-S2-HVAC FRAMING PLAN-GNOTLS-SECTIONS-48-87022029,dwg, 11-26-13, 1159pm, mariag, 48
4x6 D.F. #2 P.T.
1/2"0 LAG SCREW @ EA.
CORNER INTO EXISTING
FRAMING BELOW (4" EMBED)
NEW D.F. #2 4x6 EA. END
LAG SCREW PER SECT. @
EA. 4X CROSS MEMBER
INTO EXIST. GLB.
NEW LAG SCREW
PER SECT. @ EA.
CORNER INTO 4X &
EXIST. PURLIN
EQ.
EXISTING GLB.
PURLINS @ 8'-0" oc
\\
��
�
"
�.
NEW MECH. UNIT.
WEIGHT & LOCATION
PER MAIN ROOF PLAN
EXTEND 6PAST
EXISTING PURLIN, TYP.
NEW D.F. #2 4x6 EA. SIDE
EXISTING GLB GIRDER
EQ.
MECH. UNIT FRAMING PLAN Er-0
NOTE:
1. LOCATE C.G. OF UNIT OVER GLB. GIRDER
2. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS & DIMENSIONS
3. THIS SECTION APPLIES TO ALL NEW UNITS SHOWN ON ROOF FRAMING PLAN.
11
SECTION
C.G. OF
MECH. UNIT
1 /2" Q LAG SCREW @ EA 4x
INTO GLB. (EMBED 4")
SIMPSON "HU46"
HGRS. TYP.
EXIST. GLB GRIDER
EXIST. PIPE COL.
EXIST. GLB PURLIN
3/4" = 1-0"
1/4" = 1'-0
MECH. UNIT & MAX. WT. PER PLAN.
LOCATE C.G. OVER GLB CNETER LINE.
NOTE: ATTACHEMENT OF MECH. UNIT
TO CURB BY OTHERS
METAL CURB BY OTHERS ATTACH TO 4X
W/10d COMM. @ 6" oc & 1/2" 0x4" LAG
SCREW @ EA. CORNER
EXIST. PLYWOOD ROOF SHEATHING
GENERAL NOTE
THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE
ASTM'S NOTED ARE TO BE LATEST EDITION
1. DESCRIPTION
Building Name & Site Location - Costco Wholesale - Trkwila, WA
2. DESIGN CODE AND STANDARDS
Applicable Code (Edition/Name) - 2009 International Building Code (IBC)
Other documents referenced by these notes shall be the specific edition referenced by the
building code specified above, or if not specified, shall be the latest edition.
3. DESIGN LOADS"
a. Roof Live Load
b. Seismic
c. Wind Load
d. Dead loads
e. Special Loads
f. Load Combinations
25 "psf
Ss = 1.429, S1 = 0.489, I = 1.0, Site Class "D", SDS
= 0.953, SDI = 0.493, Seismic Design Category = "D".
Basic wind speed 85 (mph).
Exposure C.
Importance factor 1.0.
Collateral bads were not included in uplift design
Weight of structure.
The following special Toads are to be considered:
Mechanical equipment on roof.
Sprinkler lines, canopy & other reactions as noted on structural drawings.
All Code required load combinations are to be used in the building design,
Column reactions from these load combinations are to be given to the foundation engineer.
SPECIAL CONDITIONS
CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL PROVIDE ADEQUATE SHORING
AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CONTRACTOR SHALL NOTIFY
ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION.
ABBREVIATIONS
ARCH.
B. OR BOT.
BTWN.
BLDG
C.I.P.
CLR.
CNTR.
CON.
CONT.
CONTR.
DIA.
EA.
EL. OR ELEV.
E.N.W. OR ENW
E.F.
E.W.
F.O.C.
F.O.P.
F.O.S.
F.O.W
FTG.
H. OR HORIZ.
H.S.S.
I.F.
INC.
ARCHITECT
BOTTOM
BETWEEN
BUILDING
CAST IN PLACE
CLEAR
CENTER
CONCRETE
CONTINUOUS
CONTRACTOR
DIAMETER
EACH
ELEVATION
ENGINEERS NORTHWEST
EACH FACE
EACH WAY
FACE OF CONCRETE
FACE OF PLYWOOD
FACE OF STUD
FACE OF WALL
FOOTING
HORIZONTAL
HOLLOW STRUCTURAL SECTION
INSIDE FACE
INCLUDING
KB
L.L.H.
L.L.V.
M.A.S.
M.B.S.
N.F.
N.T.S.
oc
O.F.
OPNG.
O.T.O.
PNL.
REINF.
R.O.
SW
SIM.
SYMM.
T.
T.O.F.
T.S.
TYP.
U.N.O.
V. OR VERT.
V.I.F.
V.O.F.
w/
KWIK BOLT
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MASONRY (CLAY OR CMU)
METAL BLDG SUPPLIER
NEAR FACE
NOT TO SCALE
ON CENTER
OUTSIDE FACE
OPENING
OUT TO OUT
PANEL
REINFORCING
ROUGH OPENING
SHEARWALL
SIMILAR
SYMMETRICAL
TOP
TOP OF FOOTING
TUBE STEEL
TYPICAL AT ALL SIMILAR PLACES
UNLESS NOTED OTHERWISE
VERTICAL
VERTICAL INSIDE FACE
VERTICAL OUTSIDE FACE
WITH
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 0 6 2014
City of Tukwila
SUILDING DIVISION
0007
RECEIVED
CITY OF TUKWILA
JAN 2 8 2014
PERMIT CENTER
W
1-
0
DRAWING REVISIONS ,
DRAWING SUBMITTALS
SUBMIT FOR PERMIT
SUBMIT FOR BID
SUBMIT FOR CONSTRUCTION
Z
I
W
0
DRAWING REVISIONS
Ci
z
0
C
We
ZO�
WV
iii
1—
z-
1— w
= 0
CD U
JOB NO:
87022029
ENGINEER:
W. CHEN
DRAWN:
M.T.G.
DATE:
11-25-13
SHEET NO:
S2
MS\1 71 M-
70-179\12-
■
I
/ FIELD -V_RIFY 0
OF EXITING B
PERATION
ACKDRAFT
,.... ...ACE AS
NECESSARY.
■
SEE DETA
M-2
FIELD VERIFY OPER4
OF EXISTING BACKD
DAMPERS. REPLACE
NECESSARY
TION
AFT
AS
DIFFUSER TO
BE MOUNTED
AS CLOSE TO
COLUMN AS
POSSIBLE.
19
M-2
29
M-2
UNIT CENTER
OF GRAVITY OF
TO BE ABOVE
COLUMN.
1-1/2" GAS
(1650 MBH)
CONNECT NEW 1-1/2"
GAS TO EXISTING
1-1/2" GAS APPROX.
HERE.
■
FIELD VERIFY OPERATION
OF EXISTING BACKDRAFT
DAMPERS. REPLACE AS
NECESSARY.
1
FIELD VERIFY OPERATION
OF EXISTING BACKDRAFT
DAMPERS. REPLACE AS
NECESSARY.
r
N
■
1
-IELD VERIFY OPERATI
OF EXISTING BACKDRA
DAMPERS. REPLACE AS
ARY.
o�
FIELD VERIFY OPERATION
OF EXISTING BACKDRAFT
DAMPERS. REPLACE AS
NECESSARY.
■
�ry
FIELD VERIFY OPERATION
OF EXISTING BACKDRAFT
DAMPERS. REPLACE AS
NECESSARY.
1
(E)1 G 1/2'' 0 5 PSI
0
PRIOR TO INSTALLATION
. VERIFY EXISTING DUCT DROPS ARE FREE AND CLEAR OF SPRINKLER
PIPING, STRUCTURAL MEMBERS, ETC.
2. PROVIDE DIMENSIONAL DATA TO . COIL TECH FOR EACH DUCT DROP. FOR
FABRICATION ALLOW 4 WEEK LEAD TIME FOR FABRICATION AND SHIPPING.
3. DIFFUSER REPLACEMENT OPTION.
IF INTERFERENCE OR OTHER CIRCUMSTANCES PROHIBIT EASY REPLACEMENT
OF THE ENTIRE DUCT PACKAGE PROVIDE EXISTING DUCT SIZE INFO FOR
ATTACHMENT OF NEW DIFFUSER TO EXISTING SUPPLY DUCT.
4. VERIFY EXISTING UNIT NUMBER AND MODEL IN SCHEDULE.
5. VERIFY ANY STRUCTURAL PLANS MATCH MECHANICAL PLANS PLANS.
G G
o -o
MAIN MECH & ELEC PLAN
SCALE: 1/16" = 1'-0"
FIELD VERI EXISTING INDE ENDENT 1-1/2"
GAS LINE 0.5 PSI PREVIOL SLY SERVING
COFFEE RO STER HAS BEEN CAPPED AND
HAS NO OTHER CONNECTION 3.
"
FIELD VERIFY OPERATION
OF EXISTING BACKDRAFT
DAMPERS. REPLACE AS
NECESSARY.
0
INMIIIIIIM11111II1111111111II1-I
•
rl
■
GENERAL MECHANICAL NOTES
THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPUCABLE.
1. M.C. SHALL ASSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH
CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES TRANE
UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR
AND LOCATED WHERE EASILY VISIBLE FROM THE. ROOF HATCH.
2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE.
3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO
DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION
EQUIPMENT OR PANELS.
4. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE
FIELD INSPECTOR AT TIME OF INSPECTION.
5. DIMENSIONS ARE TO COLUMN LINES.
6. APPLICABLE BUILDING CODE IBC 2012
APPLICABLE MECHANICAL CODE: IMC 2012
APPLICABLE ENERGY CODE: 2012 WSEC.
7. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER.
8. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS AND FLUES BETWEEN THE ROOF AND
CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT
ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE.
9. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED.
MECHANICAL PLAN NOTES
SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE.
INSTALL NEW HEATING UNIT. MC TO LOCATE ROOF PENETRATIONS AND
ROOF CURB FOR M.B.S. AND/OR G.C. PENETRATIONS SHALL BE SUCH
THAT SUPPLY, RETURN AND/OR EXHAUST DUCT DROPS CAN EXTEND
STRAIGHT DOWN TO CEILING SPACE OR DIFFUSER PACKAGE.
RELOCATION OF ANY UNIT FROM WHERE SHOWN ON PLAN SHALL BE
APPROVED . BY ARCHITECT PRIOR TO UNIT INSTALLATION.
COORDINATE EQUIPMENT LOCATION WITH LIGHTS, BLDG. STRUCTURE,
PIPING, SWAY BRACING AND SKYLIGHTS. SEE ARCHITECTURAL,
STRUCTURAL AND ELECTRICAL PLANS. LOCATE SALES FLOOR AC UNITS
BETWEEN RACKS. CENTER SUPPLY DUCT DROP OPENING BETWEEN
JOISTS. REQUIRED CLEARANCE FOR ROOFTOP UNIT IS SHOWN.
0
•
X--
X
FIELD VERIFY OPERATION
OF EXISTING BACKDRAFT
DAMPERS. REPLACE AS
NECESSARY.
0
GAS SIZE
CHART
PRESSURE
PSI
5
PRESSURE
DROP PSI
TO 1.5
MAX -DEVELOPED
LENGTH (FEET)
300
PIPE SIZE( UPC)
MAX LOAD (MBH)
1/2" -
499
3/4"
1,044
1" .
. 1,966
1-1/4"
4,036
1-1/2"
6,048
2" -
11,647
2-1/2"
18,564
3"
- 32,818
4"
66,939
6"
-196,092
. 8" - -
- 402,893
PROVIDEONEOF FOLLOWING
REGULATORS AT EACH PIECE OF
EQUIPMENT UP TO 400 MBH
SENSUS MODEL - 496
PIPE SIZE - 3/4" OR 1"
ORIFICE . - 3/8"
SPRING - GREEN
MAXITROL MODEL - 325-5AL.600
PIPE SIZE - 3/4" OR 1"
GAS SIZE
-CHART
PRESSURE
IN WC
7 .
PRESSURE
DROP
0.5
MAXDEVELOPED
LENGTH (FEET)
100
PIPE SIZE ( UPC)
MAX LOAD (MBH)
1/2" .
- 47
3/4"
98
1"
185 -
1-1 /4"
380
1-1/2''
570
2"
1,098
2-1/2"
1,750
3"
3,093
4"
6,309
6"
18,483
8"
37,976
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 06 2014
City of Tukwila
BUILDING DIVISION
1%I110007
a
HVAC
LEGEND
1
1
C
0
0
CONT.
TYP.
CFM
DB
DG -
WB
MBH
ESP
RA
SA
CO
VD
MBS
M.0
G.0 .
SUPPLY DUCT UP
RETURN DUCT UP
SUPPLY DUCT DOWN
RETURN DUCT DOWN
CONDENSATE DRAIN
AIR CONDITIONER #1
THERMOSTAT -
THERMOSTAT (W/LOCKING COVER)
SENSOR
CONTINUATION
TYPICAL
CUBIC FEET PER MINUTE
DRY BULB TEMPERATURE
DOOR GRILLE
WET BULB TEMPERATURE
1,000 BRITISH THERMAL UNITS/HR.
EXTERNAL STATIC PRESSURE
RETURN AIR
SUPPLY AIR -
CLEAN OUT
VOLUME DAMPER
METAL BUILDING SUPPLIER RECEIVE
CITY OF TUK
MECHANICAL CONTRACTOR
GENERAL CONTRACTOR JAN 2 8 2t
AND HVAC
E_4
0
z
w
c.)
z
D�
14
cn
z
ce
REVISION DATE: NOVEMBER
M
r
0
N
0
ISSUE DATE: SEPTEMBER
ARCHITECT REFERENCE NO:
w
J
0
z
zw
1
w
w0
a_
OH
Uz
w
00
�w
0
za
M_
U
0-1-
0
11-
0�
p_
az
Z O
0
z
w
0
CL
ISSUED FOR PERMIT
HEAT PUMPS REMOVED FROM SCOPE
AC-10 THROUGH AC-12 REMOVED FROM SCOPE
re)
O
O
M
It) •
N
O
I 11
cr
PERMIT CENTER
7:34:52 AM
0
71 V1-2.dwg,
0
0
0
1
ECONOMIZER HOOD
4
ROOF CURB—�
ROOF
SUPPLY DUCT DIFFUSER
PACKAGE INSTALLED BY
M.C.
NOTE: -
(1) SEE SCHEDULE FOR ITEMS PROVIDED BY OWNER.
(2) CENTER SUPPLY DUCT FOR UNIT BETWEEN JOISTS.
PROVIDE SEISMIC
[BRACING
PER
LOCAL CODE
L
CURB. AND COUNTER
FLASHING PER ARCH.
PROVIDE HOLD DOWN
CABLE
PER DETAIL
6
My
SEE FIRE PROTECTION
DRAWINGS FOR SMOKE
DETECTOR REQUIREMENTS.
PROVIDED BY FIRE ALARM
CONTRACTOR INSTALLED BY
M.C.
(SEE SPEC FOR FIRE ALARM
CONTRACTOR RESPONSIBILITY)
ROOF MOUNTED AC UNIT DETAIL
SCALE NONE
NOTE:
M.0 TO COORDINATE DROP SIZES PRIOR TO
ORDERING. M.C. RESPONSIBLE .FOR ALL FIELD
MODIFICATION FROM INCORRECT DIMENSIONS
DURING ORDERING.
FOR INSTALLATION INSTRUCTIONS, CONTACT
COIL TECH.
(509)891-2751
NOTE: FOR 3-WAY PACKAGE, ROTATE VANES
TO CLOSE OFF BACK SIDE OF DRUM
LOUVERS TO MATCH H AIR FLOW DIRECTIONS
PER PLAN.
GHU UNITS
3-WAY
17,000 CFM UNIT
ROOF TOP MECHANICAL UNIT HOLD DOWNS
(WIND SPEED EXPOSURE PER STRUCTURAL)
OPERATING
WEIGHT(LBS)
WIND SPEED
EXPOSURE
85
M.P.H.
90
M.P.H:
100
M.P.H.
110
M.P.H.
120
M.P.H.
130
M.P.H.
140
M.P.H.
150
M.P.H.
1.5-2 TON
425-500#
LONG SIDE
2
2
2
2
2
2
2
3
SHORT SIDE
2
2
2
2
2
2
2
2
3,-5 TON
625-1200#
LONG SIDE
2
2
2
2
3
4
5
6.
SHORT SIDE
2
2
2
2
2
2
2
2
6N10 TON
915-1480#
LONG SIDE
2
2
2
3
4
5
6
7
SHORT SIDE
2
2
2
2
2
2
2
2
12.5 TON
1550-1875#
LONG SIDE
3
3
3
3
4
5
6
7
SHORT SIDE
2
2
2
2
2
2
2
2
15N25 TON
2220-3500#
LONG SIDE
3
3
3
4
5
6
8
10
SHORT SIDE
2
2
2
2
2
2
2
2
ROOF TOP AC UNIT
DO NOT BLOCK
ACCESS PANELS
NEOPRENE GASKET
BY M.C.
RIGID INSULATION
ROOF DECK
340P500
CLEVIS
3/16" SS
AIRCRAFT CABLE
SS
7"
NO. 12 SELF DRILLING
SCREW (TYP. OF 2)
HOLD DOWN CABLE SUPPLIED BY
OWNER, INSTALLED BY M.C.
14 GA. ROOF CURB. SEE
SCHEDULE FOR PROVIDER
TRANE AC UNIT HOLD DOWN CABLE
SCALE: NONE
AC DIFFUSER CONFIGURATION & DIFFUSER PACKAGE
SCALE: NONE
TE
10
FROM
TITUS 30/15
DRUM LOUVER
(TYP. OF 8)
PORT
ALL MINIMUM.
E DIAMETERS
M OUTLET.
PRV
TEST PORT
AC
GAS SHUT OFF PROVIDED BY MC
GAS PIPING ASSEMBLY
GAS SUPPLY FROM BLDG.
GAS PIPING DIAGRAM
SCALE: NONE
HVAC EQUIPMENT SCHEDULE-S.O.I.C.
SYMBOL
ITEM
SERVES
MFR/#
DESCRIPTION
ELECT.
WEIGHT
REFERENCE
REMARKS
NOTES
GHU-14
GAS HEATING
MAIN
TRANE
DIRECT FIRED GAS HEATING UNIT
460V/30
1300#:UNIT
PLAN M-1
100% 0/A
(1)
(2) (3)
UNIT
SALES
DFOA218FN
HE1AGKO3A
1650 MBH INPUT, 1518 MBH OUTPUT, 100% AFUE
25' EDB, 80' TEMP RISE 0 17,000 CFM & 1.0" ESP
15 HP
200#CURB
800#DIFF
6/M-2
UNIT TO BE U.L. LISTED
(4)
(5)
2300#:TOTAL _
29/M-2
GENERAL NOTES:
- ALL EQUIPMENT FURNISHED BY COSTCO-, INSTALLED BY M.C. CONTACT COSTCO PURCHASING DEPT. TO COORDINATE DELIVERY TIME 0 FAX (425)313-6770
- AC UNITS PROVIDED WITH COMM INTERFACE CONTROLLED BY MANUFACTURER PROVIDED T'STAT.
AC UNITS TO BE SUPPLIED WITH ECONOMIZER, BAROMETRIC RELIEF, THROW -AWAY FILTERS, AND HINGED ACCESS DOORS.
- AC UNITS TO BE SUPPLIED WITH THROUGH THE BASE ELECTRICAL WITH CIRCUIT BREAKER, 120V/15AMP CONVENIENCE OUTLET, AND THROUGH THE BASE GAS PIPING CONNECTION
UNLESS OTHERWISE NOTED.
- CONTRACTOR TO INSTALL ALL ITEMS LISTED IN EQUIPMENT SUBMITTAL AS FIELD INSTALLED. INSTALL PER MANUFACTURERS INSTALLATION AND OPERATION MANUAL.
(1) ROOF CURBS BY G.C.
(2)HVAC SUPPLY/RETURN DUCT DROP S.O.I.C.
3OUTSIDE AIR CONTROLLED BY CO2 SENSOR TO MAINTAIN MAXIMUM 1000 PPM CO2 AND MAINTAIN THE BUILDING AT A POSITIVE STATIC PRESSURE
(4) UNITS TO BE SUPPLIED WITH VARIABLE FREQUENCY DRIVE.
(5 CENTER OF GRAVITY OF UNIT TO BE DIRECTLY ABOVE COLUMN.
(6 NOT USED
(7 NOT USED
(8)NOT USED
(9NOT USED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 06 2014
City of Tukwila
BUILDING DIVISION
P&NOOO7
RECEIVED
CITY .OF TUKWILA
JAN 2 8 2014
HVAC SCHEDULE AND
a
z
0
0
N
ce
w
m
O
z
REVISION DATE:
M
0
N
0
ISSUE DATE: SEPTEMBER
ARCHITECT REFERENCE NO:
PROJECT NO:
ISSUED FOR PERMIT
HEAT PUMPS REMOVED FROM SCOPE
AC-10 THROUGH AC-12 REMOVED FROM SCOPE
M
0
r
N)
N
L)
PERMIT CENTER
7:34:56 AM
Costco -
2\170-179\12-
ELECTRICAL DEMOLITION & REMODEL GENERAL NOTES
FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID.
REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING.
BACK TO THE NEXT ACTIVE. OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED.
REMOVE OR ABANDON ALL UNUSED UNDERGROUND, UNDER FLOOR RACEWAYS. REMOVE WIRES.
REMOVE ALL UNUSED SURFACE RACEWAYS..
RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW
LOCATION, PROVIDE NEW CONNECTION AS REQUIRED.
PROVIDE CUTTING, PATCHING FOR ALL RELATED ELECTRICAL WORK AS REQUIRED.
INFORMATION ON THE EXISTING INSTALLATION HAS BEEN OBTAINED FROM THE BEST SOURCE AVAILABLE BUT CANNOT
BE GUARANTEED ACCURATE IN ALL RESPECTS. PRIOR TO BID, IT IS THE CONTRACTORS'S RESPONSIBILITY TO VISIT
THE SITE. VERIFY ALL SUCH INFORMATION AND THOROUGHLY FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS.
ALL WORKS SHALL BE PERFORMED TO CHANGE THE EXISTING ELECTRICAL INSTALLATION .AS SHOWN. INCLUDE AS PART
OF THE CONTRACT ALL RELATED WORKS REQUIRED TO OBTAIN THE INDICATED RESULTS.
ALL EXISTING WIRING, CONDUITS, JUNCTION BOXES AND ALL OTHER ELECTRICAL EQUIPMENT AND DEVICES IN THE
AREAS AFFECTED BY .THE REMODEL SHALL BE REMOVED AND RELOCATED AS REQUIRED. EXTEND ALL CONDUITS AND
WIRING.
ALL WORKS ARE TO BE DONE SO AS NOT TO INTERFERE WITH THE WAREHOUSE'S NORMAL OPERATION. ALL WORKS
ARE TO BE COORDINATED AND SCHEDULED AS APPROVED BY THE WAREHOUSE MANAGER FOR ELECTRICAL SHUTDOWN,
CONTINUITY OF SERVICE, ETC.
COORDINATE AND SCHEDULE WITH OWNER FOR ANY EXISTING ELECTRICAL SERVICE SHUTDOWN, PROVIDE TEMPORARY
POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR WAREHOUSE'S NORMAL OPERATION AS REQUIRED. TEMPORARY
POWER SOURCES INCLUDE GENERATOR SET, POWER COMPANY'S TEMPORARY SERVICE HOOKUP, ETC.
E.C. TO PROVIDE NEW TYPED INDEX FOR EXISTING PANELS AFFECTED BY THIS REMODEL. TURN 'OFF' ALL SPARE
BREAKERS AND PROVIDE 'SPARE' LABEL
ELECTRICAL LEGEND
lime BRANCH PANEL
Nos EXISTING PANEL
---- CONDUIT IN CEILING OR WALL, 1 /2" MIN.
Pal HOME RUN TO PANEL WITH CIRCUIT NUMBER, SLASHES
INDICATE NUMBER OF CONDUCTORS
#Q INDICATES WIRES AND CONDUIT OTHER THAN #12,1/2"C
C METALLIC CONDUIT
® DUPLEX RECEPTACLE
GFI GROUND FAULT CIRCUIT INTERRUPTER
WP WATERPROOF
s' FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER
Cr NON —FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER
TYP. TYPICAL
Ll L2 L3
OPTIONAL POWERED GFCI
401ACBL)
400A(RD)
401A
(BL)
UNIT
DISCONNECT
W1
(RD)
(BL)
(B3
K)
COMPRESSOR
CONTACTOR
0 0 0
of
SERVICE
RECEPTACLE
\DISCONNECT
402A(RD) 403A03L)
FU12 O O FU13
404C<RD) 405C(BL)
CGR)I
(RD) 0 o (BR)
NWT .wv
120 V
0 o OK)
410A(WH)
SERVICE PPF25.1
RECEPTACLE PLUG PPM25.1
SERVICE
RECEPTACLE
TRANSFORMER
411ACBK)
APPF25.2.
PM25,2
412ACWH) _ 413A(BK)
(GR)
SERVICE
15 AMP RECEPTACLE
120V - GFCI
UNIT DISCONNECT SWITCH AND CONVENIENCE OUTLET
UL — YCD ROOFTOP A/C UNITS
AC FACTORY INSTALLED DISCONNECT
AND CONVENIENCE OUTLET WIRING DIAGRAM
NO SCALE
EXISTING MDP
EXISTING 2500 A CU BUS, 480 VOLT, 3 0, 4W
1 T
1 EXISTING 1 EXISTING
400A/3P — 400A/3P,
400AF (LPJ) = 400AF (LPJ)
EXISTING
PANEL
H3
EXISTING
FEEDER
EXISTING
PANEL
PP1
EXISTING
• FEEDER
PARTIAL ONE LINE DIAGRAM
NO SCALE
E-2
PANEL: H3 ' 480 /. 277 VOLTS 13 PHASE 4 WIRE
400 A CU BUS M.L.O. A.I.C. MIN.
EXISTING FEED tSURFACE MOUNT.
CIRCUIT USE
PHASE
A
(KVA)
B.
C
BKR.
CKT.CKT.
NO.
NO.
BKR.
PHASE
A
(KVA)
B
C .
CIRCUIT USE
1
2
SPARE
15/3
3
4
15/3
SPARE
5
6
7
8
SPARE
30/3
9
10
15/3
SPARE
11
12
13
14
SPARE
20/3
15
16
50/3
SPARE
17
18
19
20
SPARE
50/3
21
22
15/3
SPARE
23
24
25
26
SPARE
15/3
27
28
20/3
SPARE
29
30
31
32
SPARE
50/3
33
34
40/3
SPARE
35
36
37
38
SPARE
50/3
39
40
110/3
SPARE
41
42
SECTION 2 OF 2
2.16
43
44
AC-3 '
' 2.16
15/3
45
46
110/3
SPARE
2.16
47
48
13.54
49.
50
5.57
AC-8
13.54
70/3
51
52
40/3
5.57
GHU-14 *
13.54
53
54
5.57
11.45
55
56
AC-9
11.45
60/3
57
58
30/3
SPARE
11.45
59
60
61
62
SPARE
20/3
63
64
30/3
SPARE
65
66
67
68
SPARE
20/3
69
70
20/3
SPARE
71-72
'73
74
SPARE
20/3
75
76
15/3
SPARE
77
78
SPACE
. .
79
80
SPACE
SPACE
81
82
SPACE
SPACE
83
84
SPACE
TOTAL PHASE A (KVA)
TOTAL PHASE B (KVA)
TOTAL PHASE C (KVA)
27.15
27.15
27.15
32.72 KVA
32.72 KVA
32.72 KVA
5.57
5.57
5.57
TOTAL CONNECTED LOAD
98.16 KVA
118 A
* NEW. LOAD. E.C. TO PROVIDE NEW BREAKER AS REQUIRED. E.C. TO FIELD VERIFY AVAILABLE SPACE/ SPARE PRIOR TO BID
4'G 1'4- 0007
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
CITY OF TUKWILA
JAN 2 8 2014
LINE DIAGRAM,
W
z
O
0
w
C.)
w
U
REVISION DATE: NOVEMBER
ISSUE DATE: SEPTEMBER
ARCHITECT REFERENCE NO:
J
z
Z
0
0
O 1-
0 z
W
O OZ
W U
(n Z
W
CO EE
>-
p
ZCL
gw
U I -
Or
Ci
O
s 1-
O cr
H0_
0_ Z
OCY
Z
O
PROJECT NO: 1
♦
1
®ge
01O H
ISSUED FOR PERMIT
HEAT PUMPS REMOVED FROM SCOPE
AC-10 THROUGH AC-12 REMOVED FROM SCOPE
M
v
10/25/13,
11/12/1.3
C.
r
T.E., Inc.
830 N. RIVERSIDE DRIVE
SUITE #200
RENTON, WA 98057
PHONE: 425-970-3753
1
uu
HVAC — MS
1
PERMIT CENTER
HVAC _MS\_171 E-2.dwg,
CD
ELECTRICAL POWER PLAN
SCALE: 1/16" = 1'-O"
EXISTING PANEL H3 ON
MEZZANINE
EXISTING
PANEL P13
PLAN NOTES:
01 NOT USED.
O AC UNITS ARE LOCATED ON ROOF. VERIFY
EXACT LOCATION WITH- M.C. BEFORE ROUGH -IN
INSTALLATION. HVAC POWER SHALL BE
OVERHEAD. DO NOT RUN CONDUIT ON ROOF.
DISCONNECT AND RECEPTACLE ARE PART OF
UNIT (SEE DETAIL 1 /E-.1-)
03 EXISTING UNIT TO REMAIN
0007
SEPARATE
PERMITAND
APPROVAL
REQUIRED
RECEIVED
CITY OF TUKWILA
JAN 2 8 2014
PERMIT CENTER
ELECTRICAL PLAN
REVISION DATE: NOVEMBER
ISSUE DATE: SEPTEMBER
ARCHITECT REFERENCE NO:
ISSUED FOR PERMIT
HEAT PUMPS REMOVED FROM SCOPE
AC-10 THROUGH AC-12 REMOVED FROM SCOPE
09/10/13
830 N. RIVERSIDE DRIVE
SUITE #200
RENTON, WA 98057
PHONE:. 425-970-3753