Loading...
HomeMy WebLinkAboutPermit PG14-0007 - COSTCO - GAS LINE TO ROOFTOP UNITCOSTCO 400 COSTCO DR PG1 4-0007 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2523049063 400 COSTCO DR Project Name: COSTCO PLUMBING/GAS PIPING PERMIT Permit Number: PG14-0007 Issue Date: 2/7/2014 Permit Expires On: 8/6/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: COSTCO WHOLESALE CORPORATIO 999 LAKE DR PROPERTY TAX DEPT 006, ISSAQUAH, WA, 98027 ALLEN TURNER 19430 68 AVE S , KENT, WA, 98032 KEY MECH CO OF WASHINGTON Address: 19430 68 AV S, SUITE B , KENT, WA, 98032 License No: KEYMEW*240NZ Lender: Name: Address: Phone: (253) 872-7392 Phone: (253) 872-7392 Expiration Date: 4/1/2015 DESCRIPTION OF WORK: TIE INTO EXISTING 1 1/2" CAPPED GAS LINE Valuation of Work: $1,826.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $126.76 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 2 /1/ ( 4 Print Name: L\c.1.- .V4 11 Lt►2r.►�t�, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 8: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 9: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 10: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING CITY OF TUKt "A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Plumbing/Gas Permit No. ` DO M Project No. Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4 Ga s'TGa b ‘2 I \/ King Co Assessor's Tax No.: 9'2"*.=)4"toc.,. 3a5 Tenant Name: G44TGa \\/Neie)IZ 9 PROPERTY OWNER Name: b S_'Ga \V i4 o t-.EQI._.F- Address: gelq L.Av_e_ t7lz lye. City: LAAIA State: \VQ Zip 002, CONTACT PERSON — person receiving all project communication Name: A 1...IeU.S `C't.t 1210.1E12 Address: IA430 -66AJ, City: t-V-T State: \va 4003Z Phon 5, _viz -i3g2 F 53-g-12. 73�8 Emaila±tA li, n re ICIc`(WIEG4.4t41 LAL . GoM Suite Number: Floor: 1 New Tenant: ❑ Yes No PLUMBING CONTRACTOR INFORMATION Company Name: te_ta....( *.,‘ %�04 43.4t.d1.... Address: (q 4 30 - Co� 'L Avm • S • City:1L..el.4`j' State: \vim Zi.so32 Phones Fax Q-p�,Tr2-'13G8 gg,67z...73ct2 Ic rvl a \ 24OIrl7 Expo/ `:124.15 Tukwila Business License N -LA-1 G�t...1.- �� • 3�t �- 301 Valuation of Project (contractor's bid price): $ I( e...) Z.& ./ � l Scope of Work (please provide detailed information): 1' I � 1 h1T0 I - t ST 1 (Z 4..a1P 9tE rD 44.S k_ 1 c t \s.J Ta P a Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh ktIr)-) OVA Page 1 of 2 Indicate type of plumbing fixtures and/or piping outlets being installed and the quantit} ow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets I Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value •of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING MTIOR ED AGENT: Signature: Print Name: A • Mailing Address: Ia '4 3 6 - Lg.) 4.1E. 4, Date: I f% f (A - Day Telephone: 2 5'3 - 53/ x - -j 5et ke.v4T \\/4. 3 7 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $126.76 PG14-0007 Address: 400 COSTCO DR Apn: 2523049063 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R968 R000.322.900.04.00 $4.88 $126.76 Date Paid: Tuesday, January 28, 2014 Paid By: KEY MECHANICAL CO. OF WASHINGT Pay Method: CHECK 2552 Printed: Tuesday, January 28, 2014 12:47 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit 1'497 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project;, t'rSTa Type of Inspection: FtN4C 6AsetPL. Date Called: Address: Special Instructions:, Date Wanted: . Requester: Phone No: ®Approved per applicable codes. El Corrections required prior to approval. COMMENTS: REI1 SPECTION FEE REQUIR . Prior ton xt inspection, fee/must be aid at 6300 Southcenter Blvd. Suite 100. C ll to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0007 PROJECT NAME: COSTCO DATE: 01/28/2014 SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Pf1N( O 2-0 S 9 Building Division Public Works n Fire Prevention Structural n Planning Division n Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 01/30/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 02/27/14 Approved with Conditions l'Rk Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire D Ping ❑ PW ❑ Staff Initials: 12/18/2013 KEY MECH CO OF WASHINGTO1' " Page 1 of 3 Washington State Department of Labor & Industries KEY MECH CO OF WASHINGTON Owner or tradesperson HEISLER, ROBERT L Principals HEISLER, ROBERT L FRANK LEONARD LEE SANDAHL Doing business as KEY MECH CO OF WASHINGTON WA UBI No. 600 196 154 19430 68TH AVE S STE B KENT, WA98032 253-872-7392 KING, County Business type Corporation Governing persons License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. KEYMEW*240NZ Effective — expiration 08/09/1976 — 04/01/2015 Bond LIBERTY MUTUAL INS CO Bond account no. 023011682 Received by L&I 03/23/2009 Active. Meets current requirements. $12,000.00 Effective date 04/01/2009 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600196154&LIC=KEYMEW*240NZ&SAW= 02/07/2014 G\Users\mariag\appdata\locat\temp\AcPublish_3024\COS-TUKVILA-S1-HVAC ROOF FRAMING PLAN-192-87022029,dwg, 11-26-13, 1t59pm, Mariag, 192 REVISIONS ""1 No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fe F FRAMING PLAN NOTES: 1.) ALL ITEMS ARE EXISTING (E) UNLESS NOTED AS NEW(N). 2.) FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. NOTIFY ENW IF EXISTING DIMENSIONS AND EXISTING CONDITIONS ARE NOT AS SHOWN ON PLANS AND SECTIONS. 1/16" = 1'-0" 500'-0" EPA ATE FERMI REQ IRED FOR htmbinq ❑ as Pipng Ci of Tukwila BUILD 11G DIVISIO STING ' LB GI' PERS, E ISTING ONCR•TE WLLS B OW, P. REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION FI! Cop, Permit No. _ �W I �-`DOD' Plan review Approval of the v olation of approved ey approval is subject to errors and omission% construction documents doe of any adopted code or ordinan .. Field Copy end conditions is.acknowlel g Data 2 /1 / 4 Oty Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN282014 PERMIT CENTER co 0 rn co 7 0001 U 0 w 0 DRAWING REVISIONS DRAWING SUBMITTALS SUBMIT F'OR PERMIT SUBMIT FOR BID SUBMIT FOR CONSTRUCTION w 0 DRAWING REVISIONS ci z ROOF FRAMING PLAN z w 2 0 CO U JOB NO: 87022029 ENGINEER: W. CHEN DRAWN: M. GARCINI DATE: 11-25-13 SHEET NO: S 1 U\_pre88\87022\87022029\COS-TUKWILA-S2-HVAC FRAMING PLAN-GNOTLS-SECTIONS-48-87022029,dwg, 11-26-13, 1159pm, mariag, 48 4x6 D.F. #2 P.T. 1/2"0 LAG SCREW @ EA. CORNER INTO EXISTING FRAMING BELOW (4" EMBED) NEW D.F. #2 4x6 EA. END LAG SCREW PER SECT. @ EA. 4X CROSS MEMBER INTO EXIST. GLB. NEW LAG SCREW PER SECT. @ EA. CORNER INTO 4X & EXIST. PURLIN EQ. EXISTING GLB. PURLINS @ 8'-0" oc \\ �� � " �. NEW MECH. UNIT. WEIGHT & LOCATION PER MAIN ROOF PLAN EXTEND 6PAST EXISTING PURLIN, TYP. NEW D.F. #2 4x6 EA. SIDE EXISTING GLB GIRDER EQ. MECH. UNIT FRAMING PLAN Er-0 NOTE: 1. LOCATE C.G. OF UNIT OVER GLB. GIRDER 2. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS & DIMENSIONS 3. THIS SECTION APPLIES TO ALL NEW UNITS SHOWN ON ROOF FRAMING PLAN. 11 SECTION C.G. OF MECH. UNIT 1 /2" Q LAG SCREW @ EA 4x INTO GLB. (EMBED 4") SIMPSON "HU46" HGRS. TYP. EXIST. GLB GRIDER EXIST. PIPE COL. EXIST. GLB PURLIN 3/4" = 1-0" 1/4" = 1'-0 MECH. UNIT & MAX. WT. PER PLAN. LOCATE C.G. OVER GLB CNETER LINE. NOTE: ATTACHEMENT OF MECH. UNIT TO CURB BY OTHERS METAL CURB BY OTHERS ATTACH TO 4X W/10d COMM. @ 6" oc & 1/2" 0x4" LAG SCREW @ EA. CORNER EXIST. PLYWOOD ROOF SHEATHING GENERAL NOTE THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE ASTM'S NOTED ARE TO BE LATEST EDITION 1. DESCRIPTION Building Name & Site Location - Costco Wholesale - Trkwila, WA 2. DESIGN CODE AND STANDARDS Applicable Code (Edition/Name) - 2009 International Building Code (IBC) Other documents referenced by these notes shall be the specific edition referenced by the building code specified above, or if not specified, shall be the latest edition. 3. DESIGN LOADS" a. Roof Live Load b. Seismic c. Wind Load d. Dead loads e. Special Loads f. Load Combinations 25 "psf Ss = 1.429, S1 = 0.489, I = 1.0, Site Class "D", SDS = 0.953, SDI = 0.493, Seismic Design Category = "D". Basic wind speed 85 (mph). Exposure C. Importance factor 1.0. Collateral bads were not included in uplift design Weight of structure. The following special Toads are to be considered: Mechanical equipment on roof. Sprinkler lines, canopy & other reactions as noted on structural drawings. All Code required load combinations are to be used in the building design, Column reactions from these load combinations are to be given to the foundation engineer. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. ABBREVIATIONS ARCH. B. OR BOT. BTWN. BLDG C.I.P. CLR. CNTR. CON. CONT. CONTR. DIA. EA. EL. OR ELEV. E.N.W. OR ENW E.F. E.W. F.O.C. F.O.P. F.O.S. F.O.W FTG. H. OR HORIZ. H.S.S. I.F. INC. ARCHITECT BOTTOM BETWEEN BUILDING CAST IN PLACE CLEAR CENTER CONCRETE CONTINUOUS CONTRACTOR DIAMETER EACH ELEVATION ENGINEERS NORTHWEST EACH FACE EACH WAY FACE OF CONCRETE FACE OF PLYWOOD FACE OF STUD FACE OF WALL FOOTING HORIZONTAL HOLLOW STRUCTURAL SECTION INSIDE FACE INCLUDING KB L.L.H. L.L.V. M.A.S. M.B.S. N.F. N.T.S. oc O.F. OPNG. O.T.O. PNL. REINF. R.O. SW SIM. SYMM. T. T.O.F. T.S. TYP. U.N.O. V. OR VERT. V.I.F. V.O.F. w/ KWIK BOLT LONG LEG HORIZONTAL LONG LEG VERTICAL MASONRY (CLAY OR CMU) METAL BLDG SUPPLIER NEAR FACE NOT TO SCALE ON CENTER OUTSIDE FACE OPENING OUT TO OUT PANEL REINFORCING ROUGH OPENING SHEARWALL SIMILAR SYMMETRICAL TOP TOP OF FOOTING TUBE STEEL TYPICAL AT ALL SIMILAR PLACES UNLESS NOTED OTHERWISE VERTICAL VERTICAL INSIDE FACE VERTICAL OUTSIDE FACE WITH REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 6 2014 City of Tukwila SUILDING DIVISION 0007 RECEIVED CITY OF TUKWILA JAN 2 8 2014 PERMIT CENTER W 1- 0 DRAWING REVISIONS , DRAWING SUBMITTALS SUBMIT FOR PERMIT SUBMIT FOR BID SUBMIT FOR CONSTRUCTION Z I W 0 DRAWING REVISIONS Ci z 0 C We ZO� WV iii 1— z- 1— w = 0 CD U JOB NO: 87022029 ENGINEER: W. CHEN DRAWN: M.T.G. DATE: 11-25-13 SHEET NO: S2 MS\1 71 M- 70-179\12- ■ I / FIELD -V_RIFY 0 OF EXITING B PERATION ACKDRAFT ,.... ...ACE AS NECESSARY. ■ SEE DETA M-2 FIELD VERIFY OPER4 OF EXISTING BACKD DAMPERS. REPLACE NECESSARY TION AFT AS DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE. 19 M-2 29 M-2 UNIT CENTER OF GRAVITY OF TO BE ABOVE COLUMN. 1-1/2" GAS (1650 MBH) CONNECT NEW 1-1/2" GAS TO EXISTING 1-1/2" GAS APPROX. HERE. ■ FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 1 FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. r N ■ 1 -IELD VERIFY OPERATI OF EXISTING BACKDRA DAMPERS. REPLACE AS ARY. o� FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. ■ �ry FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 1 (E)1 G 1/2'' 0 5 PSI 0 PRIOR TO INSTALLATION . VERIFY EXISTING DUCT DROPS ARE FREE AND CLEAR OF SPRINKLER PIPING, STRUCTURAL MEMBERS, ETC. 2. PROVIDE DIMENSIONAL DATA TO . COIL TECH FOR EACH DUCT DROP. FOR FABRICATION ALLOW 4 WEEK LEAD TIME FOR FABRICATION AND SHIPPING. 3. DIFFUSER REPLACEMENT OPTION. IF INTERFERENCE OR OTHER CIRCUMSTANCES PROHIBIT EASY REPLACEMENT OF THE ENTIRE DUCT PACKAGE PROVIDE EXISTING DUCT SIZE INFO FOR ATTACHMENT OF NEW DIFFUSER TO EXISTING SUPPLY DUCT. 4. VERIFY EXISTING UNIT NUMBER AND MODEL IN SCHEDULE. 5. VERIFY ANY STRUCTURAL PLANS MATCH MECHANICAL PLANS PLANS. G G o -o MAIN MECH & ELEC PLAN SCALE: 1/16" = 1'-0" FIELD VERI EXISTING INDE ENDENT 1-1/2" GAS LINE 0.5 PSI PREVIOL SLY SERVING COFFEE RO STER HAS BEEN CAPPED AND HAS NO OTHER CONNECTION 3. " FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 0 INMIIIIIIM11111II1111111111II1-I • rl ■ GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPUCABLE. 1. M.C. SHALL ASSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES TRANE UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE. ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. 5. DIMENSIONS ARE TO COLUMN LINES. 6. APPLICABLE BUILDING CODE IBC 2012 APPLICABLE MECHANICAL CODE: IMC 2012 APPLICABLE ENERGY CODE: 2012 WSEC. 7. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. 8. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS AND FLUES BETWEEN THE ROOF AND CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE. 9. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. MECHANICAL PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. INSTALL NEW HEATING UNIT. MC TO LOCATE ROOF PENETRATIONS AND ROOF CURB FOR M.B.S. AND/OR G.C. PENETRATIONS SHALL BE SUCH THAT SUPPLY, RETURN AND/OR EXHAUST DUCT DROPS CAN EXTEND STRAIGHT DOWN TO CEILING SPACE OR DIFFUSER PACKAGE. RELOCATION OF ANY UNIT FROM WHERE SHOWN ON PLAN SHALL BE APPROVED . BY ARCHITECT PRIOR TO UNIT INSTALLATION. COORDINATE EQUIPMENT LOCATION WITH LIGHTS, BLDG. STRUCTURE, PIPING, SWAY BRACING AND SKYLIGHTS. SEE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS. LOCATE SALES FLOOR AC UNITS BETWEEN RACKS. CENTER SUPPLY DUCT DROP OPENING BETWEEN JOISTS. REQUIRED CLEARANCE FOR ROOFTOP UNIT IS SHOWN. 0 • X-- X FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 0 GAS SIZE CHART PRESSURE PSI 5 PRESSURE DROP PSI TO 1.5 MAX -DEVELOPED LENGTH (FEET) 300 PIPE SIZE( UPC) MAX LOAD (MBH) 1/2" - 499 3/4" 1,044 1" . . 1,966 1-1/4" 4,036 1-1/2" 6,048 2" - 11,647 2-1/2" 18,564 3" - 32,818 4" 66,939 6" -196,092 . 8" - - - 402,893 PROVIDEONEOF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT UP TO 400 MBH SENSUS MODEL - 496 PIPE SIZE - 3/4" OR 1" ORIFICE . - 3/8" SPRING - GREEN MAXITROL MODEL - 325-5AL.600 PIPE SIZE - 3/4" OR 1" GAS SIZE -CHART PRESSURE IN WC 7 . PRESSURE DROP 0.5 MAXDEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC) MAX LOAD (MBH) 1/2" . - 47 3/4" 98 1" 185 - 1-1 /4" 380 1-1/2'' 570 2" 1,098 2-1/2" 1,750 3" 3,093 4" 6,309 6" 18,483 8" 37,976 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 06 2014 City of Tukwila BUILDING DIVISION 1%I110007 a HVAC LEGEND 1 1 C 0 0 CONT. TYP. CFM DB DG - WB MBH ESP RA SA CO VD MBS M.0 G.0 . SUPPLY DUCT UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT - THERMOSTAT (W/LOCKING COVER) SENSOR CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS/HR. EXTERNAL STATIC PRESSURE RETURN AIR SUPPLY AIR - CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER RECEIVE CITY OF TUK MECHANICAL CONTRACTOR GENERAL CONTRACTOR JAN 2 8 2t AND HVAC E_4 0 z w c.) z D� 14 cn z ce REVISION DATE: NOVEMBER M r 0 N 0 ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: w J 0 z zw 1 w w0 a_ OH Uz w 00 �w 0 za M_ U 0-1- 0 11- 0� p_ az Z O 0 z w 0 CL ISSUED FOR PERMIT HEAT PUMPS REMOVED FROM SCOPE AC-10 THROUGH AC-12 REMOVED FROM SCOPE re) O O M It) • N O I 11 cr PERMIT CENTER 7:34:52 AM 0 71 V1-2.dwg, 0 0 0 1 ECONOMIZER HOOD 4 ROOF CURB—� ROOF SUPPLY DUCT DIFFUSER PACKAGE INSTALLED BY M.C. NOTE: - (1) SEE SCHEDULE FOR ITEMS PROVIDED BY OWNER. (2) CENTER SUPPLY DUCT FOR UNIT BETWEEN JOISTS. PROVIDE SEISMIC [BRACING PER LOCAL CODE L CURB. AND COUNTER FLASHING PER ARCH. PROVIDE HOLD DOWN CABLE PER DETAIL 6 My SEE FIRE PROTECTION DRAWINGS FOR SMOKE DETECTOR REQUIREMENTS. PROVIDED BY FIRE ALARM CONTRACTOR INSTALLED BY M.C. (SEE SPEC FOR FIRE ALARM CONTRACTOR RESPONSIBILITY) ROOF MOUNTED AC UNIT DETAIL SCALE NONE NOTE: M.0 TO COORDINATE DROP SIZES PRIOR TO ORDERING. M.C. RESPONSIBLE .FOR ALL FIELD MODIFICATION FROM INCORRECT DIMENSIONS DURING ORDERING. FOR INSTALLATION INSTRUCTIONS, CONTACT COIL TECH. (509)891-2751 NOTE: FOR 3-WAY PACKAGE, ROTATE VANES TO CLOSE OFF BACK SIDE OF DRUM LOUVERS TO MATCH H AIR FLOW DIRECTIONS PER PLAN. GHU UNITS 3-WAY 17,000 CFM UNIT ROOF TOP MECHANICAL UNIT HOLD DOWNS (WIND SPEED EXPOSURE PER STRUCTURAL) OPERATING WEIGHT(LBS) WIND SPEED EXPOSURE 85 M.P.H. 90 M.P.H: 100 M.P.H. 110 M.P.H. 120 M.P.H. 130 M.P.H. 140 M.P.H. 150 M.P.H. 1.5-2 TON 425-500# LONG SIDE 2 2 2 2 2 2 2 3 SHORT SIDE 2 2 2 2 2 2 2 2 3,-5 TON 625-1200# LONG SIDE 2 2 2 2 3 4 5 6. SHORT SIDE 2 2 2 2 2 2 2 2 6N10 TON 915-1480# LONG SIDE 2 2 2 3 4 5 6 7 SHORT SIDE 2 2 2 2 2 2 2 2 12.5 TON 1550-1875# LONG SIDE 3 3 3 3 4 5 6 7 SHORT SIDE 2 2 2 2 2 2 2 2 15N25 TON 2220-3500# LONG SIDE 3 3 3 4 5 6 8 10 SHORT SIDE 2 2 2 2 2 2 2 2 ROOF TOP AC UNIT DO NOT BLOCK ACCESS PANELS NEOPRENE GASKET BY M.C. RIGID INSULATION ROOF DECK 340P500 CLEVIS 3/16" SS AIRCRAFT CABLE SS 7" NO. 12 SELF DRILLING SCREW (TYP. OF 2) HOLD DOWN CABLE SUPPLIED BY OWNER, INSTALLED BY M.C. 14 GA. ROOF CURB. SEE SCHEDULE FOR PROVIDER TRANE AC UNIT HOLD DOWN CABLE SCALE: NONE AC DIFFUSER CONFIGURATION & DIFFUSER PACKAGE SCALE: NONE TE 10 FROM TITUS 30/15 DRUM LOUVER (TYP. OF 8) PORT ALL MINIMUM. E DIAMETERS M OUTLET. PRV TEST PORT AC GAS SHUT OFF PROVIDED BY MC GAS PIPING ASSEMBLY GAS SUPPLY FROM BLDG. GAS PIPING DIAGRAM SCALE: NONE HVAC EQUIPMENT SCHEDULE-S.O.I.C. SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES GHU-14 GAS HEATING MAIN TRANE DIRECT FIRED GAS HEATING UNIT 460V/30 1300#:UNIT PLAN M-1 100% 0/A (1) (2) (3) UNIT SALES DFOA218FN HE1AGKO3A 1650 MBH INPUT, 1518 MBH OUTPUT, 100% AFUE 25' EDB, 80' TEMP RISE 0 17,000 CFM & 1.0" ESP 15 HP 200#CURB 800#DIFF 6/M-2 UNIT TO BE U.L. LISTED (4) (5) 2300#:TOTAL _ 29/M-2 GENERAL NOTES: - ALL EQUIPMENT FURNISHED BY COSTCO-, INSTALLED BY M.C. CONTACT COSTCO PURCHASING DEPT. TO COORDINATE DELIVERY TIME 0 FAX (425)313-6770 - AC UNITS PROVIDED WITH COMM INTERFACE CONTROLLED BY MANUFACTURER PROVIDED T'STAT. AC UNITS TO BE SUPPLIED WITH ECONOMIZER, BAROMETRIC RELIEF, THROW -AWAY FILTERS, AND HINGED ACCESS DOORS. - AC UNITS TO BE SUPPLIED WITH THROUGH THE BASE ELECTRICAL WITH CIRCUIT BREAKER, 120V/15AMP CONVENIENCE OUTLET, AND THROUGH THE BASE GAS PIPING CONNECTION UNLESS OTHERWISE NOTED. - CONTRACTOR TO INSTALL ALL ITEMS LISTED IN EQUIPMENT SUBMITTAL AS FIELD INSTALLED. INSTALL PER MANUFACTURERS INSTALLATION AND OPERATION MANUAL. (1) ROOF CURBS BY G.C. (2)HVAC SUPPLY/RETURN DUCT DROP S.O.I.C. 3OUTSIDE AIR CONTROLLED BY CO2 SENSOR TO MAINTAIN MAXIMUM 1000 PPM CO2 AND MAINTAIN THE BUILDING AT A POSITIVE STATIC PRESSURE (4) UNITS TO BE SUPPLIED WITH VARIABLE FREQUENCY DRIVE. (5 CENTER OF GRAVITY OF UNIT TO BE DIRECTLY ABOVE COLUMN. (6 NOT USED (7 NOT USED (8)NOT USED (9NOT USED REVIEWED FOR CODE COMPLIANCE APPROVED FEB 06 2014 City of Tukwila BUILDING DIVISION P&NOOO7 RECEIVED CITY .OF TUKWILA JAN 2 8 2014 HVAC SCHEDULE AND a z 0 0 N ce w m O z REVISION DATE: M 0 N 0 ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: PROJECT NO: ISSUED FOR PERMIT HEAT PUMPS REMOVED FROM SCOPE AC-10 THROUGH AC-12 REMOVED FROM SCOPE M 0 r N) N L) PERMIT CENTER 7:34:56 AM Costco - 2\170-179\12- ELECTRICAL DEMOLITION & REMODEL GENERAL NOTES FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING. BACK TO THE NEXT ACTIVE. OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED. REMOVE OR ABANDON ALL UNUSED UNDERGROUND, UNDER FLOOR RACEWAYS. REMOVE WIRES. REMOVE ALL UNUSED SURFACE RACEWAYS.. RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW LOCATION, PROVIDE NEW CONNECTION AS REQUIRED. PROVIDE CUTTING, PATCHING FOR ALL RELATED ELECTRICAL WORK AS REQUIRED. INFORMATION ON THE EXISTING INSTALLATION HAS BEEN OBTAINED FROM THE BEST SOURCE AVAILABLE BUT CANNOT BE GUARANTEED ACCURATE IN ALL RESPECTS. PRIOR TO BID, IT IS THE CONTRACTORS'S RESPONSIBILITY TO VISIT THE SITE. VERIFY ALL SUCH INFORMATION AND THOROUGHLY FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. ALL WORKS SHALL BE PERFORMED TO CHANGE THE EXISTING ELECTRICAL INSTALLATION .AS SHOWN. INCLUDE AS PART OF THE CONTRACT ALL RELATED WORKS REQUIRED TO OBTAIN THE INDICATED RESULTS. ALL EXISTING WIRING, CONDUITS, JUNCTION BOXES AND ALL OTHER ELECTRICAL EQUIPMENT AND DEVICES IN THE AREAS AFFECTED BY .THE REMODEL SHALL BE REMOVED AND RELOCATED AS REQUIRED. EXTEND ALL CONDUITS AND WIRING. ALL WORKS ARE TO BE DONE SO AS NOT TO INTERFERE WITH THE WAREHOUSE'S NORMAL OPERATION. ALL WORKS ARE TO BE COORDINATED AND SCHEDULED AS APPROVED BY THE WAREHOUSE MANAGER FOR ELECTRICAL SHUTDOWN, CONTINUITY OF SERVICE, ETC. COORDINATE AND SCHEDULE WITH OWNER FOR ANY EXISTING ELECTRICAL SERVICE SHUTDOWN, PROVIDE TEMPORARY POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR WAREHOUSE'S NORMAL OPERATION AS REQUIRED. TEMPORARY POWER SOURCES INCLUDE GENERATOR SET, POWER COMPANY'S TEMPORARY SERVICE HOOKUP, ETC. E.C. TO PROVIDE NEW TYPED INDEX FOR EXISTING PANELS AFFECTED BY THIS REMODEL. TURN 'OFF' ALL SPARE BREAKERS AND PROVIDE 'SPARE' LABEL ELECTRICAL LEGEND lime BRANCH PANEL Nos EXISTING PANEL ---- CONDUIT IN CEILING OR WALL, 1 /2" MIN. Pal HOME RUN TO PANEL WITH CIRCUIT NUMBER, SLASHES INDICATE NUMBER OF CONDUCTORS #Q INDICATES WIRES AND CONDUIT OTHER THAN #12,1/2"C C METALLIC CONDUIT ® DUPLEX RECEPTACLE GFI GROUND FAULT CIRCUIT INTERRUPTER WP WATERPROOF s' FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER Cr NON —FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER TYP. TYPICAL Ll L2 L3 OPTIONAL POWERED GFCI 401ACBL) 400A(RD) 401A (BL) UNIT DISCONNECT W1 (RD) (BL) (B3 K) COMPRESSOR CONTACTOR 0 0 0 of SERVICE RECEPTACLE \DISCONNECT 402A(RD) 403A03L) FU12 O O FU13 404C<RD) 405C(BL) CGR)I (RD) 0 o (BR) NWT .wv 120 V 0 o OK) 410A(WH) SERVICE PPF25.1 RECEPTACLE PLUG PPM25.1 SERVICE RECEPTACLE TRANSFORMER 411ACBK) APPF25.2. PM25,2 412ACWH) _ 413A(BK) (GR) SERVICE 15 AMP RECEPTACLE 120V - GFCI UNIT DISCONNECT SWITCH AND CONVENIENCE OUTLET UL — YCD ROOFTOP A/C UNITS AC FACTORY INSTALLED DISCONNECT AND CONVENIENCE OUTLET WIRING DIAGRAM NO SCALE EXISTING MDP EXISTING 2500 A CU BUS, 480 VOLT, 3 0, 4W 1 T 1 EXISTING 1 EXISTING 400A/3P — 400A/3P, 400AF (LPJ) = 400AF (LPJ) EXISTING PANEL H3 EXISTING FEEDER EXISTING PANEL PP1 EXISTING • FEEDER PARTIAL ONE LINE DIAGRAM NO SCALE E-2 PANEL: H3 ' 480 /. 277 VOLTS 13 PHASE 4 WIRE 400 A CU BUS M.L.O. A.I.C. MIN. EXISTING FEED tSURFACE MOUNT. CIRCUIT USE PHASE A (KVA) B. C BKR. CKT.CKT. NO. NO. BKR. PHASE A (KVA) B C . CIRCUIT USE 1 2 SPARE 15/3 3 4 15/3 SPARE 5 6 7 8 SPARE 30/3 9 10 15/3 SPARE 11 12 13 14 SPARE 20/3 15 16 50/3 SPARE 17 18 19 20 SPARE 50/3 21 22 15/3 SPARE 23 24 25 26 SPARE 15/3 27 28 20/3 SPARE 29 30 31 32 SPARE 50/3 33 34 40/3 SPARE 35 36 37 38 SPARE 50/3 39 40 110/3 SPARE 41 42 SECTION 2 OF 2 2.16 43 44 AC-3 ' ' 2.16 15/3 45 46 110/3 SPARE 2.16 47 48 13.54 49. 50 5.57 AC-8 13.54 70/3 51 52 40/3 5.57 GHU-14 * 13.54 53 54 5.57 11.45 55 56 AC-9 11.45 60/3 57 58 30/3 SPARE 11.45 59 60 61 62 SPARE 20/3 63 64 30/3 SPARE 65 66 67 68 SPARE 20/3 69 70 20/3 SPARE 71-72 '73 74 SPARE 20/3 75 76 15/3 SPARE 77 78 SPACE . . 79 80 SPACE SPACE 81 82 SPACE SPACE 83 84 SPACE TOTAL PHASE A (KVA) TOTAL PHASE B (KVA) TOTAL PHASE C (KVA) 27.15 27.15 27.15 32.72 KVA 32.72 KVA 32.72 KVA 5.57 5.57 5.57 TOTAL CONNECTED LOAD 98.16 KVA 118 A * NEW. LOAD. E.C. TO PROVIDE NEW BREAKER AS REQUIRED. E.C. TO FIELD VERIFY AVAILABLE SPACE/ SPARE PRIOR TO BID 4'G 1'4- 0007 SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA JAN 2 8 2014 LINE DIAGRAM, W z O 0 w C.) w U REVISION DATE: NOVEMBER ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: J z Z 0 0 O 1- 0 z W O OZ W U (n Z W CO EE >- p ZCL gw U I - Or Ci O s 1- O cr H0_ 0_ Z OCY Z O PROJECT NO: 1 ♦ 1 ®ge 01O H ISSUED FOR PERMIT HEAT PUMPS REMOVED FROM SCOPE AC-10 THROUGH AC-12 REMOVED FROM SCOPE M v 10/25/13, 11/12/1.3 C. r T.E., Inc. 830 N. RIVERSIDE DRIVE SUITE #200 RENTON, WA 98057 PHONE: 425-970-3753 1 uu HVAC — MS 1 PERMIT CENTER HVAC _MS\_171 E-2.dwg, CD ELECTRICAL POWER PLAN SCALE: 1/16" = 1'-O" EXISTING PANEL H3 ON MEZZANINE EXISTING PANEL P13 PLAN NOTES: 01 NOT USED. O AC UNITS ARE LOCATED ON ROOF. VERIFY EXACT LOCATION WITH- M.C. BEFORE ROUGH -IN INSTALLATION. HVAC POWER SHALL BE OVERHEAD. DO NOT RUN CONDUIT ON ROOF. DISCONNECT AND RECEPTACLE ARE PART OF UNIT (SEE DETAIL 1 /E-.1-) 03 EXISTING UNIT TO REMAIN 0007 SEPARATE PERMITAND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA JAN 2 8 2014 PERMIT CENTER ELECTRICAL PLAN REVISION DATE: NOVEMBER ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: ISSUED FOR PERMIT HEAT PUMPS REMOVED FROM SCOPE AC-10 THROUGH AC-12 REMOVED FROM SCOPE 09/10/13 830 N. RIVERSIDE DRIVE SUITE #200 RENTON, WA 98057 PHONE:. 425-970-3753