Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG14-0022 - BOEING #9-94 - CAFETERIA - KITCHEN UPGRADE
BOEING #9-94 - CAFETERIA 9725 EAST MARGINAL WY S PG1 4-0022 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 0003400018 Permit Number: 9725 E MARGINAL WAY S BLDG 9- 094 BOEING #9-94 - CAFETERIA Issue Date: Permit Expires On: PG 14-0022 2/28/2014 8/27/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 MARGIE DELEON Phone: (253) 838-9780 PO BOX 249, AUBURN, WA, 98071 AUBURN MECHANICAL INC PO BOX 249 , AUBURN, WA, 98071 AUBURMI163BA Phone: (253) 838-9780 Expiration Date: 9/12/2014 DESCRIPTION OF WORK: RENOVATION/UPGRADE OF EXISTING KITCHEN. NEW FLOOR SINKS AND HOT WATER SYSTEM. INCLUDES INSTALLTION OF (2)TWO 1" REDUCED PRESSURE PRINCIPLE ASSEMBLIES WILKINS MODEL 975XL ON INDUSTRIAL COLD WATER and FILTERED WATER LINES, PLUS REPLACEMENT OF OUTSIDE GREASE INTERCEPTOR EMOVAL OF EXISTING AND INSTALLATION OF NEW ZURN Z1172 GREASE INTERCEPTOR OUTSIDE THE BUILDING. Valuation of Work: $350,000.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Fees Collected: $722.28 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: L2,L �^i_ Date: )--V ` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agr e to the conditions attached to this permit. Signature: Print Name: Date: Z^Z.l / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 14: ***PUBLIC WORKS PERMIT CONDITIONS*** 15: Call to schedule mandatory pre -construction meeting with Dave Stuckle, Public Works Inspector, (206) 433-0179. 16: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 17: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 18: Reduced Pressure Principle Assemblies (RPPAs) shall be installed per manufacturers specifications. Upon installation backflow assemblies are to be tested by a certified tester and passing test reports forwarded to the Public Works Inspector. Thereafter RPPAs annual tests shall be performed at owners expense, and copies of the test results forwarded to the Tukwila Water Department, 600 Minkler Blvd, Tukwila, WA 98188, fax: 206-575-3404. 19: ZURN Z1172 grease interceptor shall be installed and maintained per manufacturer's specifications. Every three month the Owner shall completely pump out the interceptor. At any time, the City may inspect the interceptor and require service that is more frequent. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 1600 PUBLIC WORKS FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUK V 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. k'G Project No. Date Application Accepted: �'- ` 3 Date Application Expires: a —' l 3 -1 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 5624201032 Site Address: 9725 East Marginal Way S Suite Number:Bldg 9-94 Floor: 1 Tenant Name: The Boeing Company PROPERTY OWNER _ Name: Boeing Development Center Address: 9725 East Marginal Way S City:t Tukwila State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Margie De Leon Address: P.O. Box 249 City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 833-1384 Email: margiedeleon@auburnmechanical.com New Tenant: ❑ Yes ❑✓ ..No PLUMBING CONTRACTOR INFORMATION Company Name: Auburn Mechanical Address: P.O. Box 249 City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 833-1384 Contr Reg No.: AUBURMI163BA Exp Date: 09/12/2014 Tukwila Business License No.: BUS-0100148 Valuation of Project (contractor's bid price): $ 350,000 Scope of Work (please provide detailed information): Renovation / Upgrade of existing Kitchen. New floor sinks and hot water system. Building Use (per Int'l Building Code) Commercial Kitchen Occupancy (per Int'l Building Code): Group A-2 Utility Purveyor: Water Sewer H:\Applications\Forms-Applications On Line\2011 Applications \Plumbing Permit Application Revised 8-9-I l.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gab piping outlets being installed and the quantity —iow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 Shower, single head trap Sinks 10 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) 1 Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory 2 Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment 4 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 2 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 1 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 11 Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AUTHO ; ZED%AGENT: Signature: i (i Print Name: Margie De Leon Mailing Address: P.O. Box 249 Date: a/A/25' Day Telephone: (253) 838-9780 Auburn WA 98071 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $722.28 PG14-0022 Address: 9725 E MARGINAL WAY S BLDG 9-094 Apn: 0003400018 $722.28 GAS $186.25 PERMIT FEE R000.322.100.00.00 $149.00 PLAN CHECK FEE R000.322.103.00.00 $37.25 PLUMBING $508.25 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $374.10 PLAN CHECK FEE R000.322.103.00.00 $101.65 TECHNOLOGY FEE $27.78 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1251 R000.322.900.04.00 $27.78 $722.28 Date Paid: Thursday, February 13, 2014 Paid By: AUBURN MECHANICAL Pay Method: CHECK 0011850 Printed: Thursday, February 13, 2014 2:16 PM 1 of 1 CRWSYSTEMS • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 '(206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: '_C '\ - ci 3 Type of Inspection: i= i „\ L, Addresss: r ! /�c-, z 01,1,7'(cfr•-,°-1L. Date Called: Special Instructions:. Date Wanted: t.,.- -, - '-. 1 ;a;mr . p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: • . % 24 7 /" 1/ 1 Inspector / J(iA-4 J✓J� ,//�I` r INSPECTION NO. INSPECTION RECORD Retain a copy with permit Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 'Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 on. Project:r 1��7 �� Type•of Inspectionn:: �UMh f ;rJ L. �Gi Address: 0)9ts ( F .'''"(dn/ , Date Called: .,�---- Special Instructions: 0 6, / Date Wanted:.. � //j Haan. � f yC- p.m. 0 //� Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: I REI SNPEC'1ON FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date; 0,.)*Th INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 264rov2Z Project: , G; f; ji�j 7 t(�1 . , !t. (� 1 "1 Type of Inspection: A S f, Ai A Address: ti-12-` ' E .Jt� wit. 1 AL� Date Called: . Special Instructions: r') .3 a Date Wanted: `_? - Z 5 . 1 /a.m.. p.m. Requester: Phone N Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,F_ n n t refit, V .A el A k ok _s A` / A I o (AA (_ D Alla; i P--� l e E r 0 ,tit ,) o P n - (A- n `T 1 Es-1 S1,4 5-1e0 M j'_ il,OJT, I Inspector: Date:7 1I UI REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i 0 ('G iL4 -oon INSPECTION NO, PERMIT NO. Ai INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: r 34Type o elnspect n: t Address: 1915 , fti Ar�.0 Date Calle L— fe..O uG if --/ii Special Instructions: Z. Date Want eta5 /2,3 - t zi P• Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: A 7 . (21) U 6 Inspector: (kA ) \ / REINSPECTION FEE REQUIRED. Prior to paid at 6300 Southcenter Blvd.. Suite 100. Dater 5 --- 14 next inspection, fee must be Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 o r,, Proj t: a q 6/4 Typ f Inspection:,.. a l.) (O _L Ai pp 1P Ad r :2 5 {" - j� j } Date Called: (� S Special Instructions: ."/ 214 I /// Date Wanted: r -41.03,,. Requester: t7 Phone No: proved per applicable codes. El Corrections required prior to approval. • CC iMENTS: itk A r(7 3 a irs Win: REINSPECTION FEE REQUIRED. Prior to 1 ext inspection, fee must be paId at 6300 Southcenter Blvd., Suite 100. Call : to schedule reinspection. 9 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 7c4- Dal PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670'. Permit Inspection Request Line (206) 431-2451 Project: c ( .)A!'-y -j �� Type of Inspection: (.2rJLJet\lo ki,ior k 6 Add ess: I Date Called: Special Instructions: / Date Wanted: 5 �� a.m G{- P.m. Requester: Phone No: 12 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ItOr- i C cmf) A^ 14 -r-1> 9 -61 6 /___. t ( -' J t !,-) ` i e P ,A : , .,f' Inspiector:IV.k.- Date: 2 4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ct: cj ( TYytos o(�i*Inspection: .LN.1 GA C Address: o�2� E F;Q(o1�1 - Date Called: Special Instructions: 0Are-IFZ-f Date Wanted: G-js-(L (a�'`rr1. p.m. RequesteYr: Phone No: - Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: p j� �`. , -, c (a,-." ,L - 9 b , d . 1 --1 D l f 1 Inspector: tjAA n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must (:le paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: Cam"/ - f ti iINSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION L' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 CV 2_. Project: Type of Inspection: ' - / . Address: , — 4 /L c, f I ,t&,n!.11., Date Called: - Special Instructions: ' Date Wanted: .I) it / a.m, p.m. Requester: ' Phone No: Approved per applicable codes. O Corrections required prior to approval. COMMENTS: ,l- / \ 1 o x , t 0 _ As ,„ (Y X) i i 0n ,fir / Inspector: I\U \\. Date:. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit pc) 14 - 40r122_ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 150e...Az, (1-el4. TyRe of Inspection: Ki)J6I4 rN 6A.S Address: r °). 95 F. MA/6:tuit L Date Called: ti zd ura(_i--, Special instructions: Date Wanted: -4 - 2 3" 144 a,.m:, P.m. Requester: Phonei No Co 1 3 ( ` 2 Approved per applicable codes. ICJ Corrections required prior to approval. COMMENTS: ()V- J4,r fSLD o(f„ 3,.a� ,I --UJ -r s 1 0 PS (0V-- & t S CT1 S i 00 (sl, Date, 23 + 4 REINSPECTION FEE REQUiftED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. J INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Project: C C) t1 j Type of inspection: PdaRC4b —aki Address: _ Date Called: Special Instructions: e. rot Fc-ccR(A q-(51 Date Wanted: LI— i 8 r- 144 a.m. p:m. q Re ues er: _1 Phone 6 (4=n t 1-12 t 1 Approved per applicable codes. COMMENTS: PA Corrections required prior to approval. A,rll2r v 7 1r.� .4,YU>../ .e4 4 i AP�i. A/ isr / h.f..� 1 Inspector: /( 414 ►/ REINSPECTION FEE REQUIRED. Prior to paid at 6300 Southcenter Blvd., Suite 100. Date:F/ next inspection, fee must be Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ?6(4.61o7,2.1 Project: t L oe---AG of ' 1' ( Type of inspection: 67vvn) wc2rk_ Ad4e%2S Date Called: Special Instructions: ,r, Date Wanted: Qat, 1 -10 -1 p.m. Requester: Phone 73 a kt Approved per applicable codes. Corrections required prior to approval. COMMENTS: fie (vr6JA'3r / Inspector: Date _ I O REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd.,#100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: + woe. cl Type of Inspection: ©J A-) tlt/� / Address' 1175 E, M1f(o:,)4 Date Called: ..�: Special Instructions: C� �ti Date Wanted ^4 / a -.-in: Requester Phone O- .73 L.2 -42— ElApproved per applicable codes. t__..7 Corrections required prior to approval: COMMENTS: l 1* i<. c 1 / d t (-fit T f Dater 4 REINSPECTI071 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 PG 4 -0022. Project: ' 63e..., AG CI -014 Type of Inspection: Coroun worl , Add" - 25 Date Called: Special Instructions: Date Wanted: .3 � ( ..a.m- p.m: Requester: Phone No: U 3 42Si Approved per applicable codes. COMMENTS: Corrections required prior to approval. 1 v K ! S r, I ttAlf ( / 5 d// S& eel` )G/`+ /10 Irfspector: kA Date 5 REINSPECTION PEL RE IIIREb. Prior to next ins ection. fee must be paid at 6300 Southcenter Blvd.. Suite 1.00. Call to schedule reinspection. Auburn echanical BACKFLOW PREVENTION ASSEMBLY TEST REPORT RECEIVED CITY OF TUKWILA :-rr11 i1i' .SB rstsb # P(r1K-c90�L PERMIT CENTER NAME OF PREMISE Q a �) �+ CO- Commeraal 2 Res dential ❑ SERVICE ADDRESS 41 R S E. M o-rr; xi q/ Loy_ s CITY t o is ti;l i u ZIP 4 81 o 8 CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OFASSEMBLY '�'� C G�� E I $T ioJ( ark Ere Roo 11,7 DOWNSTREAM PROCESS Pop Cli Tbk,e DCVA CI RPBA gi/BA CIOTHER 9 NEW INSTALL EXISTING 0 REPLACEMENT 0 OLD SER. # PROPER EtINSTALLATION? YES MAKE OF ASSEMBLY GAS OR t MODEL 37 cP( L— SERIAL NO. I4 35 7 11 L j sZE Yz " AUG 0 4 2014 INITIAL TEST • PASSED V FAILED ■ DCVA / RPBA DCVA / RPBA RPBA PJBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT y Z PSI D AIR INLET OPENED AT PS D LEAKED • LEAKED ■ CI— PSID #1 CHECK 7 e PSID 7- g PSID AIR GAP OK? i DID NOT OPEN ■ NEW PARTS AND REPAIRS CLEAN REPLACE PART ■ ■ CLEAN REPLACE PART ■ ■ CLEAN REPLACE PART ■ ■ CHECK VALVE HELD AT PSID LEAKED ■ ■ i• • • • • is ■ ■ ■ ■ • CLEANED ■ • • • • ■ ■ REPAIRED ■ TEST AFTER REPAIRS OPENED AT PSID AIR INLET PSID LEAKED • LEAKED • PSID PSID #1 CHECK PSID CHK VALVE PSID PASSED. • FAILED • AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No ❑ Detector Meter Rearing REMARKS LINE PRESSURE (! O PSI CONFINED SPACE? BCD TESTERS SIGNATURE: CERT. NO. A6:3-3© DATE 7 -.Za TESTERS NAME PRINTED: eh � he,rM f}iQ 2 TESTERS PHONE #( 2 5 3) 8 3 8- 9 7 8 0 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE ALIBRATION DATE S' /�5'//j GAUGE #o5 /3/Zeii MODEL > q5 - SERVICE RESTORED? YES !NO 0 /oa'tifythat Misreport Isaar" aai/Awe wad WAC246-290-4i,90a-oveitestmethoaEsaadtestagtipngt BACKFLOW PREVENTION ASSEMBLY TEST REPORT c�ri 71t # Pray-t ,zZ NAME OF PREMISE a e i C® Commerdel m der>tial 0 SERVICE ADDRESS 725- E m �,�.r, ( u,�, s CITY rt,t<ZIP 98106 CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OF ASSEMBLY 9 -9 y ccLf i & c/c Ce,og C uft, a e-A4Tror0 aea DOWNSTREAM PROCESS-ci I1-r Luart-- St-ec,m ter- DCVA 0 RPBA L K BA 0 OTHER NEW INSTALL lEiDICISTING ❑ REPLACEMENT 0 OLD SER. # PROPER INSTALLATION? YES LINO ❑ MAKE OF ASSEM BLY Cc, it xis MODEL 137 S`D(L SERIAL NO. 4 33 ! 7 5V SZE S`t y INITIAL TEST PASSED EV FAILED • DCVA / RPBA DCVA / RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT ,7. (o PSI D AIR INLET OPENED AT PSID LEAKED • LEAKED • C.1 PSID #1 CHECK 6-3 PSID k3-3 PSID AIR GAP OK? Y DID NOT OPEN • NEW PARTS AND REPAIRS CLEAN REPLACE PART ■ • CLEAN REPLACE PART ■ ■ CLEAN REPLACE PART ■ • CHECK VALVE HELD AT PSD LEAKED ■ IN ■ • • • • • • ■ ■ • ■ CLEANED ■ • • • • • • REPAIRED ■ TEST AFTER REPAIRS OPENED AT PSID AIR INLET PSID LEAKED • LEAKED • PSID PSID #1 CHECK PSID CHK VALVE PSID PASSED • FAILED ■ AIR GAP INSPECTION: Required minimum air gap separation provided? Yes 0 No 0 Detector Meter Reeving LINE PRESSURE/ / C PSI CONFINED SPACE? 11-9e7 REMARK& TESTERS SI GNATU RE: eei i®,a�°a,,� J�� CERT. NO. (j 5'.5 3 0 DATE 7 2 3 - ! y TESTERS NAME PRINTED: air is toe e4- nig t2 TESTERS PHONE # ( 2 5 3) 8 3 8- 9 7 8 0 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE AL I BRATI ON DATE S / I(j GAUGE # 05V3/2g1 MODEL Sqs- SERVICE RESTORED? YES Ig-<4O ❑ oa'e& tta' #is report is scanle4 old I have used WAC246-2.5i0-490 wp'ovaifast methods ay' test eqripna'at BACKFLOW PREVENTION ASSEMBLY TEST REPORT echanical .8SEtotStY# ptrtl-co2z., NAME OF PREMISE ®oe-tCO Commerdal C/Resdentiai 0 SERVICE ADDRESS ? 7 25 E , ►rka rsi►;t.,-a f LA.9y , _ CITY 'i( K►.c.r s (cc_ ZIP 98/O9 CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OF ASSEMBLY q—qc/ C4 J B4 ck 6,0K Lrr�e 13y. ice. mackiwt DOWNSTREAMPROCESSgi /f-r_r water -C-or ice_ m4of de� DCVA 0 RPBA 1VBA 0 OTHER NEW INSTALL I�IXISTING 0 REPLACEMENT 0 OLD SER. # PROPER INSTALLATION?YES iO 0 MAKE OF ASSEMBLYLL, si ,..J5 L MODEL ,773'X SERIAL NO. 143 7 3 2 © SIZE '/Z `� K�' INITIAL TEST PASSED FAILED • DCVA / RPBA DCVA / RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED ATK_ I%PSID AIR INLET OPENED AT PSI D KED • LEAKED • Gt— PSD #1 CHECK / PSID -1 PSID AIR GAP OK? Y DID NOT OPEN • NEW PARTS AND REPAIRS CLEAN REPLACE PART • ■ CLEAN REPLACE PART ■ ■ CLEAN REPLACE PART ■ ■ CHECK VALVE HELD AT PSID LEAKED ■ ■ N • • • • • • • • • ■ • CLEANED ■ • • • • • • REPAIRED ■ TEST AFTER REPAIRS OPENED AT MD AIR INLET PSID LEAKED ■ LEAKED • PSID PSD #1 CHECK PSI CHK VALVE PSI PASSED ■ FAILED • AIR GAP INSPECTION: Required minimum air gap separation provided? Yes 0 No 0 Detector Meter Reeding LINE PRESSURE / U) PSI CONFINED SPACE? MJ® REMARKS TESTERS SIGNATURE: TESTERS NAME PRINTED: C1riS1jptom. fi ' TESTERS PHONE#( 253) 838-9780 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE -AL IBRATION DATE S. I/ /LI GAUGE #05'/3/24ii MODEL eq — SERVICE RESTORED? YES g3NO ❑ /oertfy /saxatQ aad/hove rsatWAC246- 9043p-over/ test methods eaIlaste ripmant. CERT. NO. 853-30 DATE 7- 73- / L) BACKFLOW PREVENTION ASSEMBLY TEST REPORT erriI ft _£SEMBEYY# Ph 1%'-bO2Z NAME OF PREMISE 6 d -i,'l C 1- Commercial EitVkegdantid 0 SERVICE ADDRESS t725— E n-ICrrI tc,y,. c5 CITY +UKw /CL ZIP ?810 8 :CONTACT PERSON PHONE ( ) FAX ( LOCATION OF ASSEMBLY 4 ez4)c Cook PU e r n) H0001 LA3 G Co b i tt DOWNSTREAMPROCESSf-fooc,J wuhSSy-�,rri DCVA 0 RPBA �PVBA 0 OTHER NEW INSTALL I9 D(ISTING 0 REPLACEMENT 0 OLD SER. # PROPER INSTALLATION? YES IU4 O 0 MAKE OF ASSEMBLY Ce14 ttS MODEL 6109 rn.Z QT— SERIAL NO. 5-2 b 4 1/ SZE / A/ INITIAL TEST PASSED L�1' FAILED • DCVA / RPBA DCVA / RPBA RPBA PSI D PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT3-8 AIR INLET OPENED AT PSI ).EAKED • PSI D LEAKED • CC— PSID #1 CHECK �7-,(a PSID ? — AIR GAP OK? r DID NOT OPEN ■ NEW PARTS AND REPAIRS CLEAN REPLACE • ■ ■ • • • • • PART CLEAN REPLACE ■ ■ • • ■ • • • PART CLEAN REPLACE ■ ■ • • PART CHECK VALVE HELD AT PSID LEAKED ■ • ■ ■ • CLEANED ■ REPAIRED ■ TEST AFTER REPAIRS PSID PSID OPENED AT PSID AIR INLET PSID LEAKED ■ LEAKED • #1 CHECK PSID CH VALVE PSID PASSED • FAILED • AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No 0 Detector Meter Reacing REMARKS LINE PRESSURE 1/0 Ps CONFINED SPACE? A/ O TESTERS SIGNATURE: (v�J� /h44'J CERT. NO. PI 5.5-?0 DATE 7- 23 - l '� TESTERS PHONE#( 253) 838-9780 TESTERS NAME PRINTED: Chris toe J t,r 1Q 2 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE _ALIBRATION DATE $ /�5'//j GAUGE #o5 /3/2// MODEL gqS' SERVICE RESTORED? YES V2410 ❑ / crfi1y that Ws report /s war" acid / have used WAC 246-290490 approved test methock az( test s7[ipm . BACKFLOW PREVENTION ASSEMBLY TEST REPORT Auburn echanical .,SSSEn LY # P6,1 y , va 22, NAME OF PREMISE D P. P rur CO. Commercial Eeii denti a 0 SERVICE ADDRESS 17 2 5— i A/c,1 Ivy 5 cITY fiU K LAJ 11 L ZIP 16108 CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OF ASSEMBLY C ge. /��� ! R�tCliu ctrT L L' L.eaa/I Qv sc•e__ h7&Glit ve DOWNSTREAM PROCESS P i ! ficr wce f q- for Ice machi,uQcVA 0 RPBA L!Y PVBA 0 OTHER NEW INSTALL EXISTING ❑ REPLACEMENT ❑ OLD SER. # PROPER INSTALLATION? YES L-NO C] MAKE OF ASSEMBLY kJ ►' I k eev S MODEL 3 75AL. SERIAL NO. 351 303 SZE yz INITIAL TEST PASSED FAILED • DCVA / RPBA DCVA / RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT Y- G PSI D AIR INLET OPENED AT PSID EAKED ■ LEAKED • Gff PSD #1 CHECK si-y PSID S-q PSID AIR GAP OK? y DID NOT OPEN ■ NEW PARTS AND REPAIRS CLEAN REPLACE PART • ■ CLEAN REPLACE PART ■ • CLEAN REPLACE PART • • CHECK VALVE HELD AT PSID LEAKED ■ ■ a • • • • • • • ■ ■ • CLEANED ■ • • • • • • REPAIRED ■ TEST AFTER REPAIRS OPENED AT PSID AIR INLET PSID LEAKED • PSD LEAKED • PSD #1 CHECK PSID CHK VALVE PSID PASSED ■ FAILED • AIR GAP I NSPECTION: Required minimum air gap separation provided? Yes ❑ No 0 Detector Meter Reeving LINE PRESSURE 1/0 PSI CONFINED SPACE? Joe) TESTERS SIGNATURE: CERT. NO. 1? �S'3a DATE 7— 2 ,7— 12/ TESTERS NAM E PRI NTED: Chr is toeJ1t,,,- R?II 2 TESTERS PHONE # ( 253) 838-9780 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE -ALIBRATION DATE $ /j /LI GAUGE PVC -Caen MODEL OW" SERVICE RESTORED? YES IIl" NO ❑ / a * / that t/rs report Is scar" and have used WAC?.4lr29 90 Approved test mdivas end last equirinert REMARKS BACKFLOW PREVENTION ASSEMBLY TEST REPORT sEtvrer# a� /y a- m©zz NAME OF PREMISE 0 © %, I 9i Co- CanmercResde tial ❑ SERVICE ADDRESS 97 Z 5 E. pia r Ng ( cud. £'_`" CITY fuxt,,j f& ZIP 9 )0 8 CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OF ASSEMBLY R- /I q Cc,.c_ J i A.) Accc,k . R oo M N. E cc, r 1u e4- cs- F S ra^ v ery. DOWNSTREAM PROCESS FiI4r water -for rce me/chi-are DCVA 0 RPBA Et4VBA 0 OTHER NEW INSTALL E -' ISTING ❑ REPLACEMENT ❑ OLD SER. # PROPER INSTALLATION? YES 1fl4 o ❑ MAKE OF ASSEMBLY ku! 11< cu 5 MODEL 3 76i(L SERIAL NO. 3513 )8 SZE /C2 INITIAL TEST PASSED EK FAILED • DCVA / RPBA DCVA / RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT 3-2 PSI D AIR INLET OPENED AT PSID LEAKED • LEAKED • C,T PSID #1 CHECK 7- 7 PSID 7- 7 PSI AIR GAP OK? Y DID NOT OPEN • NEW PARTS AND REPAIRS CLEAN REPLACE PART ■ ■ CLEAN REPLACE PART • • CLEAN REPLACE PART ■ ■ CHECK VALVE HELD AT PSID LEAKED ■ ■ • • • • • • ■ • • • • • CLEANED ■ m • • • • • ; REPAIRED ■ TEST AFTER REPAIRS OPENED AT PSI AIR INLET PSI LEAKED • LEAKED • PSI D PS #1 CHECK PSI CHK VALVE PSI PASSED ■ FAILED ■ AIR GAP INSPECTION: Required minimum air gapseparation provided? Yes ❑ No 0 Detector Meter Resting LINE PRESSURE 110 PS CONFINED SPACE? 029 f'kp-1 CERT. NO. 13 53-.70 DATE 7- 2 3 -- / Lf REMARK& TESTERS SIGNATURE: TESTERS NAME PRINTED: Chris j p).,tid. 2 TESTERS PHONE#( 253) 838-9780 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE �LIBRATION DATE $ /OE //j GAUGE #O5 /3/2g1 MODEL q-' SERVICE RESTORED? YES 0 NO ❑ / asrtify that Eli; report isaaxrafa a-,il have used WAC246-291-49O q3p-ovaitest methods eV test egripment: BACKFLOW PREVENTION ASSEMBLY TEST REPORT ltA- P (,1 Y-bt zc' NAME OF PREMISE SERVICE ADDRESS ® ei 11/4.2' Cp . Canmerc LW Resdentid 0 7.25— - mct-r9/',va/ wty 5- CITY 'Fctj ,,/ et ZIP Q8/4� CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OF ASSEMBLY 5- C4 ff..) ��. jjeiy 161040r) tl, n,.19E,r. /S i Ait v Cs (fee tvleciit S - DOWNSTREAM PROCESS Cl 1 hc-r wgfcr �r Co e »KcrDCVA 0 RFBA IQ PVBA 0 OTHER NEW INSTALL It7- (STING 0 REPLACEMENT 0 OLD SER. # PROPER INSTALLATION? YES 91 O MAKE OFASSEMBLYt.t.,j 1 ►xss MODEL 3 7.5�XL SERIAL NO. AA 351309 SZE yZ N INITIAL TEST PASSED IIVDID FAILED • DCVA / RPBA DCVA / RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT 3- 7 PSI D AIR INLET OPENED AT PSI D EAKED • LEAKED • C-- PSID #1 CHECK 7- 9PSD 7- `Z1 PSD AIR GAP OK? r NOT OPEN • NEW PARTS AND REPAIRS CLEAN REPLACE PART • ■ CLEAN REPLACE PART ■ ■ CLEAN REPLACE PART is • CHECK VALVE HELD AT PSID LEAKED ■ • ■ • • • • • • • • • • CLEANED ■ • • • • • • REPAIRED ■ TEST AFTER REPAIRS OPENED AT PSD AIR INLET PSI LEAKED • PSI LEAKED • PSD #1 CHECK PSD CHK VALVE PSD PASSED ■ FAILED • AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No 0 Detector Meter Rearing REMARKS LINE PRESSURE /,LQ PS CONFINED PACE? iua- TESTERS SIGNATURE: �'� �. efi,t4 CERT. NO. 5.3-3e.) DATE 7 -23- ! �% TESTERS NAME PRINTED: Chris toeJ1cr- /S W2 TESTERS PHONE # ( 253) 838-9780 REPAIRED BY: DATE FINAL TEST BY: CERT. NO. DATE -- // CALIBRATION DATE S' /Ls /LI GAUGE #05'/ /Ze — MODEL eq SERVICE RESTORED? YES ENO 0 / oat'fy that ills report /s eoar" aid/ have used WAC246-290-9t9r1 rova:118st mel/roa(sex/test sftipmeaf. ZURN® Z1172 LARGE CAPACITY GREASE INTERCEPTOR SPECIFICATION SHEET TAG GI-1 Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION INLET 'F' G=WIDTH OF BODY OUTLET HEX HEAD SET SCREW - REMOVE SCREWS TO USE LIFT HANDLES, REPLACE SCREWS ONCE COVER IS IN PLACE AND HAND ARE REMOVED. FEB 20 2014 TV KVV I LI-, PUBLIC NORKS Size Inlet/ Outlet Size Flow Rate G.P.M. [L] Capacity N S > z° c) Approx. Wt. Lbs. [kg] Dimensions in Inches Water Gal. [L] Grease Lbs. [kg] C D/E F G 900 3 [76] 75 [284] 65 [246] 150 [68] 1 316 [143] 22-3/4 [578] 18-1/2 [470] 36 [914] 28-5/8 [727] 1000 100 [378] 110 [416] 200 [91] 408 [185] 27 [686] 23 [584] 42-3/4 [1086] 33-5/8 [854] 1200 1 150 [567] 195 [737] 300 [136] 856 [389] 30-3/4 [781] 25-1/4 [641] 56 • [1422] 41-5/8 [1057] 2 1400 5 [127] 250 [945] 465 [1758] 500 [227] 1384 [628] 41 [1041] 36 [914] 71 [1803] 51-5/8 [1311] 1500 300 [1134] 665 [2514] 600 [272] 1770 [804] 46-1/4 [1175] 39-5/8 [1006] 80 [2032] 58-5/8 [1489] 1600 6 [152] 350 [1323] 865 [3278] 700 [318] 2096 [951] 50-1/2 [1283] 43-7/8 [1114] 87 [2210] 63-5/8 [1616] 1700 400 [1512] 1095 [4139] 800 [363] 3 2440 [1108] 54-1/4 [1378] 47-5/8 [1210] 94 [2388] 67 [1702] 1800 450 [1701] 1280 [4838] 900 [409] 2710 [1230] 55-1/4 [1403] 48-5/8 [1235] 100 [2540] 72 [1829] 1900 500 [1890] 1440 [5443] 1000 [454] 2857 [1297] 57-1/4 [1454] 51-5/8 [1311] 104 [2642] 74 [1880] ENGINEERING SPECIFICATION: ZURN Z1 72 Large capacity Acid Resistant Coated interior and exterior fabricated steel grease interceptor, rated at GPM and _ Lbs. grease capacity, with internal air relief by-pass, bronze cleanout plug (which can be used as a sampling port) and visible double wall trap seal with removable pressure equalizing/flow diffusing baffle. Gasketed non-skid secured cover with removable lift handles, complete with flow control fitting. Regularly furnished with inlet and outlet in high position. RECEIVED OPTIONS (Check/specify appropriate options) PREFIXES d Z Acid Resistant Coated Fabricated Steel* ZS All Type 304 Fabricated Stainless Steel SUFFIXES _ -AL Aluminum Cover -E Acid Resistant Coated Interior and exterior fabricated steel extension section. (Specify 'C' Dim. required) for recessed installation. _ 4-ID Heavy duty traffic cover rated at 10,000 lbs. [4536 kg] maximum safe live load. An increase 'C' dim. is required when -HD option is specified. (See -HD option specification sheet) _ -K Anchor flange 1-3/4 [44] down from top and 2 [51] wide. (A 3 [76] minimum Extension Height is required when Anchor Flange (-K) Option is specified.) -KC Anchor flange 1-3/4 [44] down from top and 2 [51] wide with clamp collar. (A 3 [76] minimum Extension Height is required when Anchor 1 Flange (-KC) Option is specified.) _ -L Angle type (Z1108-L) flow control device. -PW Plug Wrench _ -RE Recessing receiver enclosed type for recessed installation. Fumished with gasketed non-skid cover with removable lift handles. (Sizes 900 & 1000 Only) CITY OF TUKWILA *REGULARLY FURNISHED UNLESS OTHERWISE SPECIFIED 411111 ZURN INDUSTRIES, LLC • SPECIFICATION DRAINAGE OPERATION • 1801 Pittsburgh Ave. • Erie, PA 16514m Phone: 8141455-0921 • Fax: 8141454.7929 • World Wide Web: www.zum.co In Canada: ZURN INDUSTRIES LIMITED ♦ 3544 Nashua Drive ♦ Mississauga, Ontario L4V1L2 • Phone: 9051405.8272 Fax: 9054405-1292 r)74qo REV. F DATE: 04/29/11 C.N. NO. 121194 DWG. NO. 67227 PRODUCT NO. Z1172 FEB 1:9 2014 PERMIT CENTER ZURN® Model 975XL Reduced Pressure Principle Assembly WILKINS Backflow Prevention Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 975XL provides protec- tion where a potential health hazard exists. Standards Compliance • ASSE® Listed 1013 • IAPMO® Listed • CSA® B64.4 • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Materials Main valve body Access covers Internals Elastomers Polymers Springs Features Sizes: 1/4", 3/8", 1/2" Cast bronze ASTM B 584 Cast bronze ASTM B 584 Stainless steel, 300 Series Silicone (FDA approved) Buna nitrite (FDA approved) NorylTM, NSF Listed Stainless steel, 300 series Maximum working water pressure Maximum working water temperature Threaded connections (FNPT) Hydrostatic test pressure REVIEWED FOR CODE COMPLIANCE APPROVED FEB 25 2014 City of Tukwila BUILDING DIVISION; 175 psi 180° F ANSI B1.20.1 350 PSI Dimensions & Weights (do not include pkg.) Options (Suffixes can be combined) --El - with full port QT ball valves (standard) ❑ L - less ball valves, male pipe thread --E S - with bronze "Y" type strainer (1/2" only) ❑ TCU - with test cocks up ❑ FT - with integral male 45° flare SAE test fitting Accessories ❑ Air gap (Model AG) ❑ Repair kits (rubber only) ❑ Thermal expansion tank (Mdl. XT) ❑ Soft seated check valve (Model 40XL) ❑ Shock arrester (Model 1250XL) ❑ QT-SET Quick Test Fitting Set Relief Valve discharge port: 1/4" - 1/2"- 0.38 sq. in. G A RECEIVE' FEB 25.2014 TUKvvlL.ti PUBLIC WORKS Ow - MODEL SIZE in. mm DIMENSIONS (approximate) WEIGHT A in. mm B in. mm C in. mm D in. mm in. E mm in. F mm G in. mm WITH VALVES Ibs BALL kg LESS BALL VALVES lbs. kg 1/4 8 9 1/2 241 5 3/4 146 1 1/2 38 2 3/4 70 2 51 4 102 N/A N/A 7 3.2 6 2.7 3/8 10 9 1/2 241 5 3/4 146 1 1/2 38 2 3/4 70 2 51 4 102 N/A N/A 7 3.2 6 2.7 1/2 15 10 254 5 3/4 146 1 1/2 38 2 3/4 70 2 51 4 102 13 1/2 343 7 3.2 6 2.7 Zurn Industries, LLC 1 Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zum Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. B Date: 12/13 Document No. BF-975XL(SM) Product No. Model 975XL(SM) www.zurn.com Page 1 of 2 PC,14co2Z Flow Characteristics • O Rated Flow (established by approval agencies) a 20 t/) N 0 15 w re y 10 N w a 50 MODEL 975XL 1/4", 3/8" & 1/2" (STANDARD & METRIC) FLOW RATES (Vs) 0.38 0.57 0.76 0.19 0.95 137 V) V) 103 69 cn 1/4" (6mm) 3/8" (9mm) 1/2" (15mm) 3 6 9 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged or where relief valve discharge could cause damage. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 25 2014 City of Tukwila BUILDING DIVISION DRAIN 12 w 35 c 15 Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4" 8 12 17 25 1" 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 78 105 167 12" MIN. 30" MAX. DIRECTION OF FLOW INDOOR INSTALLATION RECEIVED FEB252014. TUKwiLJA PUBLIC WORKS Specifications The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180° F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NoryiTM and the seat discelastomers shall be silicone. The checks shall be oriented at a 45° angle up- ward and accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap and "Y" type strainer. The Reduced Pressure Principle Backflow Preventer shall be a ZURN WILKINS Model 975XL. Zurn Industries, LLC 1 Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zum Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0022 DATE: 02/13/14 PROJECT NAME: BOEING #9-94 - CAFETERIA SITE ADDRESS: 9725 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: kwc --- Building Division II JSAV/c' 41)S-N—t � Public Works Fire Prevention Structural n Planning Division Permit Coordinator a PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 02/18/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 03/18/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 AUBURN MECHANICAL INC Page 1 of 3 Washington State Department of Labor & Industries AUBURN MECHANICAL INC Owner or tradesperson THODAY, DAVID V Principals THODAY, DAVID V JOHNSON, STACY ANNE JOHNSON, KIM PAUL Doing business as AUBURN MECHANICAL INC WA UBI No. 600 074 968 PO BOX 249 AUBURN, WA98071 253-838-9780 KING County Business type Corporation Governing persons KIMJOHNSON License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. AUBURMI163BA Effective — expiration 01 /01 /1984 — 09/12/2014 Bond Active. Meets current requirements. FIDELITY & DEPOSIT CO OF MD $12,000.00 Bond account no. LPM8047218 Received by L&I Effective date 09/12/2001 09/01/2001 Insurance Liberty Mutual Fire Insurance $1,000,000.00 Policy no. YV7Z91461553033 Received by L&I Effective date 09/30/2013 10/01/2013 Expiration date 10/01/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600074968&LIC=AUBURMI 163BA&SAW= 02/28/2014 V EC HA\ I CAL VAC' LEG \D GENERAL NOTES I•; GENERAL SYMBOL DESCRIPTION RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN MM. f 24/12 f 24/12ti DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST I/��II 11 2" 9 ROUND DUCT, NUMBER INDICATES DIAMETER 240 f f OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER 1) 24/120 4 24/120 f f SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY 11. EXHAUSUNDT,ERLBETOUW FRNACOR ING SUPPLY DSAIR DUCT RO, .. NI Er EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY IIIIII SQUARER RRRECTANGURN LARAIELBOWT, FACING TOWARDS 11m AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY ;,�EXHAUST TRANSLTION RECTANGULAR TO RECTANGULAR TRANSITION AT TAKE OFF ip IL TRANSIT ON SQUARE OR RECTANGULAR TO ROUND OR OVAL g-0,. UP DUCT OFFSET UP OR DOWN DOWN OPPOSED BLADE DAMPER i-L—P-4 PARALLEL BLADE DAMPER �i ' ^ I VOLUME DAMPER f \ f DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) 2 I BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) TM y BDD AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) FIRE DAMPER (1 HOUR) tiM f IFD -f FIRE DAMPER (2 HOUR) i! F ;FD2 f .11 REVISIONS No changes of work shall be made to th without prior approv T D --. no j - E-- .:.JJ.JJ Ykwiia cultding Division A.;..., Ts will require a new pia i.:n i r•.1 y .::. ude additional plan revi e al n GENERAL SYMBOL DESCRIPTION 1� RECTANGULAR DUCT, SQUARE ELBOW WITH TURNING VANES IL \�1� % RECTANGULAR DUCT, RADIUS VANED ELBOW EXTRACTION GRID '--j. 144---14,1 FLEXIBLE DUCT FLEXIBLE DUCT CONNECTION 00' j. —� 10o cFM SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER AND CFM AIR FLOW — ._ 100 CFM SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AND AIR FLOW 1 CFM SCREENED OPENING AND CFM AIR FLOW SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (SEE NOTE 3) i \ 4- ® . - SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 3) LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 3) RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW lie a __,� /-"-'‘._ RETURN/REUEF GRILLE, CEILING TYPE, NON -DUCTED C — \ UNIT HEATER, HORIZONTAL \I r ti UNIT HEATER, VERTICAL PROJECTION LINED DUCT ATTENUATOR fElSOUND LINED DUCT WITH ACCESS DOOR AND SMOKE DAMPER it 0 i AD SD LINED DUCT WITH AXIAL FLOW FAN Crl CENTRIFUGAL FAN Perm eJ CENTRIFUGAL FAN, PLV c1J16 fI Y a EXHAUST FAN UPPLY AIR FLOW n4E �provea r' _._ O of ! RETURN, OUTSIDE OR EXHAUSTBY FLOW DIRECTION submittal Date: i fees. r� GENERAL SYMBOL DESCRIPTION E THERMOSTAT, REMOTE, CEILING Q HUMIDISTAT, WALL E HUMIDISTAT CEILING 4D DUCT TYPE SMOKE DETECTOR PO DUCT TYPE HEAT DETECTOR SRSTATIC PRESSURE REGULATOR TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED 0 THERMOSTAT, WALL ON NIGHT THERMOSTAT E THERMOSTAT, CEILING n❑ TEMPERATURE TRANSMITTER VAV BOX LEGEND 1ST CHARACTER: V= VARIABLE AIR TERMINAL UNIT VOLUME 2ND CHARACTER: F= FAN POWERED UNIT C= SHUTOFF UNIT 3RD CHARACTER: E= ELECTRIC HEAT W= HOT WATER HEAT C= NO HEAT COIL MARK NUMBER XX X .:lao.ammo )oval is subject to errors and or t i! any adopted code or ordinance. )Id IcLititions is acknoi 1 (A1 7._--G7". 2c)( City _W •.••. am. Of Tukwila MM.Ift A!. waft MI A Ilk SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION A AAV AD ADD AF AFF AP APPROX ARCH AUD AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTUH BW C Cv 'C CAP CC CCW CFM CI COND CONN CONT CPLG CPVC CW DA DB DBD DIA 0 DIS DIR DN DS DWG dB EA EAT EFF ELL ELEC ELEV, EL ESP EVAP EWT EXH EXIST EXT 'F FC FD FLR FCO FOB FOF FOIC FOT FPM FRP FS Dry .G4t Fi ledge HORIZ HP HPC HR HVAC HPU HTG ID IE IGV INSUL IN ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CONDENSATE CONNECTION CONTINUED/CONTINUATION COUPLING CHLORINATED POLYVINYL CHLORIDE CLOCKWISE ROTATION DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DIAMETER DEIONIZED WATER SUPPLY DEIONIZED WATER RETURN DOWN DOWNSPOUT DRAWING DECIBELS EXHAUST AIR / EACH ENTER AIR TEMPERATURE ('F) EFFICIENCY ELBOW ELECTRICAL ELEVATION EXTERNAL STATIC PRESSURE EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FORWARD CURVE WHEEL FIRE DAMPER FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE GLASS FIBER REINFORCED PLASTIC FLOW SWITCH FEET FACE VELOCITY FPM GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING INSIDE DIAMETER INVERT ELEVATION INLET GUIDE VANE INSULATION INCHES SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION KW KVA LAT LBS, # LWT MA MAX MBH MCC MECH MIN MOV MTD, MTG NC NIC NO NTS NPSH OA OBD OF OS&Y OD OVHD PBD PD/oP PDI POC POS PRESS PRV PS PSIG PSV PVC QD RA RECT REF REV RH RM ROT RPM RQD RTN RV SA SCFH SCFM SHC SHF SHT SO SOV SP SQ SS STL STRUC SW SUCT TD TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP UBD VAV VD VP VERT VFA VTR W8 WCO WG WHA W/ KILOWATT KILOVOLT -AMPERE LEAVING AIR TEMPERATURE ('F) POUNDS LEAVING WATER TEMPERATURE CO MIXED AIR MAXIMUM HEAT CAPACITY BTU PER HOUR X 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE REUEF (SAFETY) VALVE POLYVINYL CHLORIDE QUICK DISCONNECT REVERSE ACTING (CON RECTANGULAR REFERENCE REVISED RELATIVE HUMIDIFY ROOM ROTATION REVOLUTIONS PER M REQUIRED RETURN ROOF VENT SUPPLY AIR STANDARD CUBIC FE STANDARD CUBIC FE SENSIBLE HEAT CAPA SENSIBLE HEAT FACT( SHEET SCREENED OPENING SOLENOID OPERATED STATIC PRESSURE SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD SUCTION TRENCH DRAIN TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL TROLLER) / RETURN AIR SEPARATE PER REQUIRED F MUTE / HR r/MIN 'ITY R C'Mechanical [electrical ❑ Plumbing ❑ Gas Piping Cityof Tukwil "'.� < LDINO DIVA UP BLAST DISCHARGE VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WALL CLEAN OUT WATER GAUGE (INCHES OF WATER) WATER HAMMER ARRESTOR WITH MIT GAR: .a BION 1. SEE DRAWINGS M1b AND FOR ADDITIONAL MECHANICAL LEGENDS AND ABBREVIATIONS. 2. SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL SYSTEMS. 3. DIFFUSER SYMBOLS WITHOUT AIR FLOW DIRECTION ARROWS INDICATE AIR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR LINEAR DIFFUSERS). AIR FLOW ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. 4. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EQUIPMENT SCHEDULES. 6. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CLOUD(S) MARKED WITH THE REVISION (REV) LETTER WHICH MATCHES THE ONE INDICATED IN THE LOWER RIGHT CORNER OF THE SHEET OR THE LATEST REV LETTER IN THE REVISION SECTION OF THE TITLE BLOCK. IF THERE IS NO CLOUD ON THE SHEET, THE ENTIRE SHEET IS IN THE SCOPE OF WORK, UNLESS IT'S A DETAIL SHEET. A DETAIL REFERENCED WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK EVEN WHEN THE ACTUAL DETAIL DRAWING IS NOT CLOUDED ON THE DETAIL SHEET. LEGEND AND GENERAL NOTES ALWAYS APPLY WHETHER CLOUDED OR NOT. CONSTRUCTION NOTES PERTAINING TO THIS JOB WILL BE CLOUDED AND MARKED WITH THE MATCHING REV LETTER UNLESS ON A SHEET WHERE THERE ARE NO CLOUDS AT ALL, THEN ALL NOTES APPLY. FLAG NOTES POINT TO SPECIFIC INSTANCES OF THE CONSTRUCTION; NUMBERED NOTES APPLY TO THE ENTIRE CONSTRUCTION AREA. 7 PROVIDE MEANS PURCHASE AND INSTALL TO COMPLETE WORKING ORDER, INTEGRATED WITH ADJACENT BUILDING ELEMENTS AND FINISH RENTS, IN FULL COMPLIANCE WITH DESIGN INTENT. INSTALL MEANS, OBTAIN ITEM(S) TO BE INSTALLED FROM OWNER AT LOCATION AS DIRECTED BY CONSTRUCTION MANAGER, AND INSTALL IN SAME MANNER AND COMPLIANCE AS IF PURCHASED. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 • Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYM REVISION CAFETERIA UPGRADE 12419164 BY SAZAN/ON APPROVED DATE SYM BY APPROVED DATE 11.26.13 elLATOE,AW ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ON SAZAN DAZE 11.20.13 APPROVED BY DEPT. DATE SUBTITLE HVAC LEGEND & ABBREVIATIONS CURRENT REVISION 12419164 SYMBOL DATE 11.26.13 LNGINELH -CHLLKEU TRU CAFETERIA UPGRADE urruANIPAI EJACTED BUILDING 09-94.1 SHEET M 1 a JOB N0. 12419164 COMP N0. Al I nn/ rrAITro WA DWG N0. no_noA_u1,, ECHA\ICAL HI\G LEGE\D GENERAL SYMBOL DESCRIPTION -1 1- BREAK IN PIPE CROSSING LINES, NO CONNECTION I DIRECTION OF FLOW -�- SLOPE DIRECTION OF SLOPE, DOWN uj EQUIPMENT MARK NUMBER "-EXIST EXISTING WORK EXISTING TO BE REMOVED f- - - HIDDEN OR BELOW GRADE -.D0- IN -LINE RECIRCULATING PUMP --6 ii- INSULATED PIPE -6 4- INSULATED PIPE WITH ELECTRIC HEAT TRACING ,NEW NEW WORK *POC POINT OF CONNECTION - PUMP FIXTURES SYMBOL DESCRIPTION 0 CIRCULAR WASHFOUNTAIN C7 SEMI -CIRCULAR WASHFOUNTAIN ELECTRIC WATER COOLER Q LAVATORY, ROUND COUNTER MOUNT ® LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT ORD (0FD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) I SAFETY EYE WASH FOUNTAIN ) SAFETY SHOWER AND EYE WASH D SERVICE SINK, FLOOR MOUNT SERVICE SINK, WALL HUNG NM SHOWER STALL AND FIXTURE D' URINAL, WALL HUNG fD WATER CLOSET, WALL HUNG Q WATER CLOSET, FLOOR MOUNT WASTE FITTINGS SYMBOL DESCRIPTION 1/4 BEND CLEAN OUT, EXPOSED -11 CO FCO CLEAN OUT, FLOOR O CLEAN OUT, WALL --1 WCO O FFD FUNNEL FLOOR DRAIN O FUD FUNNEL DRAIN 0 FD FLOOR DRAIN O FS FLOOR SINK LATERAL ICI TRENCH DRAIN 1170TM O wR WASTE RECEPTOR, ROOF 14YE AND 1/8 BEND, SHOWN WITH CLEAN OUT 1ill C0 PIPE IDENTIFICATION SYMBOL DESCRIPTION -A- COMPRESSED AIR, PLANT -AS- AQUEOUS SOLUTION -A(250)- COMPRESSED AIR, 250 PSI - C- CONDENSATE RETURN (GRAVITY) -CD- CHEMICAL DRAIN -CF- CHEMICAL FEED -CHWR- CHILLED WATER RETURN -CHWS- CHILLED WATER SUPPLY -CLD- CLEAR WATER DRAIN -CLWR- COOLING WATER RETURN -CLWS- COOLING WATER SUPPLY - CRV- CORROSION RESISTANT VENT -CRW- CORROSION RESISTANT WASTE - CTFR- COOLING TOWER FILTER RETURN - CTFS- COOLING TOWER FILTER SUPPLY -CTWR- COOLING TOWER WATER RETURN -CTWS- COOLING TOWER WATER SUPPLY -CW- DOMESTIC COLD WATER - DI - DEIONIZED WATER -DW- DISTILLED WATER - F- FIRE LINE, AHEAD OF ALARM VALVE -FH- FIRE HOSE CABINET PIPING - FOR- FUEL OIL RETURN - FOS- FUEL OIL SUPPLY - FOV- FUEL OIL VENT - G- NATURAL GAS - LOW PRESSURE -MPG- NATURAL GAS - MEDIUM PRESSURE - GN2- GASEOUS NITROGEN - HGD - REFRIGERANT HOT GAS DISCHARGE - HPC - CONDENSATE, STEAM (HIGH PRESSURE) - HPR - CONDENSATE RETURN (HIGH PRESSURE) - HPS - STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) -HPW - HOT PROCESS WATER - HPWC- HOT PROCESS WATER CIRCULATING - HW- DOMESTIC HOT WATER SUPPLY - HWC- DOMESTIC HOT WATER CIRCULATING -HWR- HEATING WATER RETURN -HWS- HEATING WATER SUPPLY -IA- INSTRUMENT AIR - ID - INDIRECT DRAIN - IW - INDUSTRIAL WASTE - PIW- INDUSTRIAL WASTE (PUMPED) -LN2- LIQUID NITROGEN - LPC - CONDENSATE, STEAM (LOW PRESSURE) - LPG - LIQUID PETROLEUM GAS -LPS- STEAM SUPPLY (LOW PRESS, 0-15 PSIG) - MPC - CONDENSATE, STEAM (MEDIUM PRESSURE) - MPS - STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) - OFD- OVERFLOW DRAIN - PA - PAINT BOOTH SERVICE AIR -PCWS- PROCESS COOLING WATER SUPPLY -PCWR- PROCESS COOLING WATER RETURN - PC- CONDENSATE RETURN (PUMPED) PIPE IDENTIFICATION SYMBOL DESCRIPTION -PCW- PROCESS COLD WATER -PHW- PROCESS HOT WATER - PTW - PROCESS TEMPERED WATER -PHWC - PROCESS HOT WATER CIRCULATING RL- REFRIGERANT LIQUID - - RS- REFRIGERANT SUCTION (GAS) - RWL- RAIN WATER LEADER -S- SPRINKLER LINE - SAN- SANITARY WASTE ABOVE GRADE OR FLOOR -- SAN-- SANITARY WASTE BELOW GRADE OR FLOOR - SPD- SUMP PUMP DISCHARGE - STM - STEAM SUPPLY -- STS-- STORM DRAIN BELOW GRADE --- TP --- TRAP PRIMER - VAC- VACUUM - VPD- VACUUM PUMP DISCHARGE PIPE FITTINGS SYMBOL DESCRIPTION BELL & SPIGOT )3 BLIND FLANGE �I BUSHING l.- IM EXPANSION JOINT -I I- FLANGED FITTING -- FLEXIBLE PIPE CONNECTION -U GROOVED COUPLING ITS HOSE BIBB NFHB HOSE BIBB - NON FREEZE PIPE ANCHOR ----( PIPE CAP SCREWED OR SOLDER JOINT PIPE CAP, WELDED OR GROOVED D PIPE CROSS 1$1 PIPE ELBOW, 90' SHORT RADIUS }SR PIPE ELBOW, 90' LONG RADIUS '} PIPE ELBOW, REDUCING PIPE ELBOW, 45' -Ik PIPE ELBOW, TURNED UP OR TOWARD -'O PIPE ELBOW, TURNED DOWN OR AWAY -'3 PIPE GUIDE = PIPE HANGER -/-- x l r PIPING MATERIAL CHANGE, X TO Y PIPE PLUG I4 PIPE REDUCER CONCENTRIC -D-- PIPE REDUCER ECCENTRIC o PIPE SUPPORT -!-- PIPE TEE, STRAIGHT -+F~ PIPE TEE, UP OR TOWARD 101 REDUCING PIPE FLANGE -ID PIPE TEE, DOWN OR AWAY -- 0' -I- SCREWED FITTING OR AS SPECIFIED I- SEISMIC HANGER f PIPE FITTINGS SYMBOL DESCRIPTION - SOLVENT CEMENT 9 SPRING HANGER UNION, FLANGED -i 1- - -I1- UNION, SCREWED WELDED FITTING 1.-- .• SOLDERED FITTING -a---e- PIPING SPECIALTIES SYMBOL DESCRIPTION I 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR SI 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR A /0 AIR DROP - HOSE, SIMPLEX / DUPLEX e / ® AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX 1, 40 ANGLE GLOBE VALVE, ELEVATION / PLAN 400 AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) - AAV AUTOMATIC AIR VENT (WITH DRAIN) e r BACKFLOW PREVENTER BALANCE VALVE WITH METERING PORTS BALANCE VALVE W/0 METERING PORTS DI4 -141-/-141- BALL VALVE, OPEN / CLOSED -lp(1 BUTTERFLY VALVE -{11- COOLING COIL CHILLED WATER FLOAT VALVE FLOWMETER, VENTURI TYPE G�1 -11H- FLOWMETER ORIFICE / GATE VALVE, OPEN / CLOSE A GATE VALVE, OUTSIDE SCREW AND YOKE GATE VALVE, WITH HOSE CONNECTION - H04-/-0 } GLOBE VALVE, OPEN / CLOSED -ri- HEATING COIL -NJ- / 4 LIFT CHECK VALVE - MAV MANUAL AIR VENT (WITH DRAIN) :: MOTOR OPERATED VALVE NEEDLE VALVE © NITROGEN DROP Q NITROGEN OUTLET PETCOCK -NI- $+141E PETE'S PLUG, WITH BALL VALVE PLUG VALVE/STOP COCK -161- ,FI PRESSURE GAUGE WITH VALVE IC., PRESSURE REGULATING VALVE W/EXT PRESS TAP PRESSURE REGULATING VALVE (SELF CONTAINED) 81 PRESSURE RELIEF VALVE / SAFETY VALVE I><1 QUICK OPENING VALVE LA QUICK CLOSING VALVE, FUSIBLE LINK A SOLENOID OPERATED VALVE -111 S STEAM TRAP - i- SWING CHECK VALVE WITH FLOW PIPING SPECIALTIES SYMBOL��yy DESCRIPTION 1 ' TEST PLUG 1*I THERMOMETER, LINE MOUNT _g_ THERMOMETER, SEPARABLE WELL MOUNT T TRAP, FLOAT 0 TRAP SEAL PRIMER VALVE -ISEI- UNCLASSIFIED VALVE A VACUUM BREAKER Q VACUUM DROP (LAB VAC) O VACUUM OUTLET (LAB VAC) HARD PIPED v VACUUM CLEANING OUTLET Q VALVE BOX VALVE IN RISER (TYPE SPECIFIED) i<C-1-- T WATER HAMMER ARRESTOR I\ WYE STRAINER (WITH DRAIN VALVE) FIRE PROTECTION SYMBOL DESCRIPTION I 2 WAY EARTHQUAKE BRACING X 4 WAY EARTHQUAKE BRACING uv ALARM VALVE, WET ® ASR AUTOMATIC SPRINKLER RISER 101 DRY PIPE VALVE ELECTRIC BELL EXISTING SPRINKLER HEADS (TO REMAIN) -0 EXISTING SPRINKLER HEADS (REMOVE) l°( X F-I FIRE HOSE CABINET •- FIRE DEPARTMENT CONNECTION, WALL TYPE .6.9DC0. FIRE DEPARTMENT CONNECTION, YARD TYPE FDC FIRE DEPARTMENT CONNECTION, FLUSH 4-1 FH FIRE HYDRANT - 2 HOSE OUTLET FIRE HYDRANT - 2 HOSE OUTLET AND PUMPER CONNECTION DO FLOW SWITCH O HALON SYSTEM AUTOMATIC DISCHARGE STATION n HALON SYSTEM, MANUAL DISCHARGE STATION -1:1Y4 GROOVED COUPLING, GROOVED CAP MONITOR SWITCH }M❑ rV POST INDICATOR VALVE, YARD T f SPRINKLER HEAD, DRY PENDENT C4b SPRINKLER HEAD, OVER AND UNDER SPRINKLER HEAD, PENDENT, IN LINE, NEW --0- 1 SPRINKLER HEAD, PENDENT, OFFSET, NEW SPRINKLER HEAD, SIDEWALL, PENDENT, NEW _Cl_ SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW -0- SPRINKLER HEAD, UPRIGHT, NEW THRUST BLOCK }ION ''''X 0 WALL INDICATOR VALVE, PLAN / ELEVATION T WMG WATER MOTOR GONG 1 TAMPER SWITCH WELDING SYMBOL DESCRIPTION ROOT DEPTH FOR SLOT EFFECTIVE THROAT SIZE STRENGTH CERTAIN OPENING OF PLUG WELDS FILLING AND FOR WELDS ` T�S \ DEIAJ DETAIL TAIL CONTOUR SYMBOL FINISH SYMBOL \/1 F A R f (E)l�h}L—P GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH (CENTER TO CENTER ACING) FIELD WELD SYMBOL ARROW CONNECTING REFERENCE LINE TO ARROW SIDE OR ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE UNE NUMBER OF SPOT OR PROIECRON WELDS r { ga} 111 (N) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED WELD SYMBOL REFERENCE OR (MAY BE OMMITTED WHEN REFS ENCE IS NOT USED SPECIFICATIONS, PROCESS OR OTHER REFERENCE p BACK WELD L. FILLET WELD p PLUG OR SLOT WELD 11 SQUARE WELD O SPOT OR PROJECTION WELD GENERAL NOTES 1. SOME ABBREVIATIONS LEGEND MAY NOT BE ARE INCLUDED HERE AND MAY BE UTILIZED DAD I F FOR )UNDSY®NLtlA � y'Wl N T '+T LIANC APPROVED FEB 2 5 2014 E City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER ISSUED FOR CONSTRUCTION 11.26.13 SAZAN GROUP 600 Stewart St, Ste 1400 Seattle, Washington 98101 (i) Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYM 81 APPROVED DATE SYM REVISION RA APPROVED DATE CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 celLA PI P,AW ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED E DEPT. DATE DRAWN ON SAZAN DATE 11.20.13 cD SUBIRIE PIPING LEGEND & ABBREVIATIONS CURRENT REVISION 12419164 SYMBOL DATE 11.26.13 GI CHECKED APPROVED APPROVED IMF CAFETERIA UPGRADE UCrI4AMIrAI I/ACTCD BUILDING 09-94.1 Al I nLIl rTAITCD WA SHEET M 1 b JOB NO. 12419164 COMP NO. DWG NO. no_ACM _I/ 1 H KITCHEN EQUIPMENT CONNECTION SCHEDULE EQUIP. N0. DESCRIPTION ROUGH —IN CONNECTION (IN REMARKS W V IW CW HW G ( 008 ) DRIP TROUGH FS — 1 1/2 — — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. HOT WATER DISPENSER FS — 1 1/2 1/2 — — PROVIDE SOV, FILTERED WATER AND APPROVED TYPE RP BFP, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FLOOR SINK. ( 009) DROP —IN SINK FS — 1 1/2 1/2 1/2 — PROVIDE SUPPLY STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ( 010 ) ICE MAKER FS 3/4 1/2 CONNECT SOV, FILTERED WATER (018) AND APPROVED TYPE RP BFP, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FS. ( 015) ( 016 ) ICE BIN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. ( 017 ) FLOOR TROUGH 3 2 — — — — FURNISH & INSTALL DRAIN AND "P" TRAP. ( 018 ) WATER FILTER — — — 1/2 — — USE WITH 015 HAND SINK W/ ELECTRONIC FAUCET 1 1/2 1 1/4 — 1/2 1/2 — FURNISH & INSTALL SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ( 019 ) COUNTER WITH SINK FS — 1 1/2 1/2 1/2 — FURNISH & INSTALL SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ( 022 ) ( 025 ) SODA DISPENSER FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 027 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 030 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 033 ) HOT FOOD WELL FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 035 ) SOUP WELLS FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 036 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. HAND SINK W/ ELECTRONIC FAUCET 1 1/2 1 1/4 — 1/2 1/2 — PROVIDE SUPPLY STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ( 039 ) COUNTER WITH SINK FS — 1 1/2 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ( 040 ) ( 045 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. EXHAUST HOOD W/ MAKE—UP AIR FS — 2 _ 1 — CONNECT 1" 140'F WATER FROM HOOD WASH SYSTEM PANEL TO WASH SOLENOID ASSEMBLY AND 2" CHROME PLATED DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. SEE 1/FS1A500 ( 046 ) ( 049 ) (6) OPEN BURNER — — — _ — 3/4 PROVIDE P.C., DIRT LEG, & FLEX CONNECTION, 150 CFH ICE MAKER FS 1 1/2 CONNECT WITH SOV, FILTERED WATER (018) AND APPROVED TYPE RP BFP, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FS. ( 052 ( 054 WATER FILTER 1/2 — — USE WITH 052 ( 060 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 064 ) PIZZA OVEN — — — _ — 3/4 PROVIDE P.C., DIRT LEG, QD & FLEX CONNECTION, 188 CFH HAND SINK W/ ELECTRONIC FAUCET 1 1/2 1 1/4 — 1/2 1/2 — PROVIDE SUPPLY STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ( 071 ) COUNTER WITH SINK FS — 1 1/2 1/2 1/2 — PROVIDE SUPPLY STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ( 076 ) EXHAUST HOOD W/ MAKE—UP AIR FS — 2 _ — — CONNECT 1" 140'F WATER FROM HOOD WASH SYSTEM PANEL TO WASH SOLENOID ASSEMBLY AND 2" CHROME PLATED DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. SEE 1/FS1A500 ( 077 ) ( 092 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 080 ) BROILER (48") — — — _ — 3/4 PROVIDE P.C., DIRT LEG AND FLEX CONNECTION, 120 CFH ( 082 ) GRIDDLE (48") — — — _ — 3/4 PROVIDE P.C., DIRT LEG AND FLEX CONNECTION, 96 CFH ( 083 ) FRYER W/ FILTER AND DUMP STATIO1 — — — _ — 1 PROVIDE P.C., DIRT LEG AND FLEX CONNECTION, 244 CFH ( 092 ) REFRIGERATED COLD PAN FS — 1 — — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 095 ) REFRIGERATED COLD PAN FS — 1 _ — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH MIN. 1" AIR GAP. ( 105 ) UNIT COOLER FS — 1 _ — — PROVIDE SLEEVE AT WALL FOR COIL DRAIN. SEE FS1A458 ICE St WATER DISPENCER FS 1 1/2 CONNECT WITH SOV, FILTERED WATER (018) AND APPROVED TYPE RP BFP, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FS. ( 107 UNIT COOLER (FREEZER) FS — 1 _ — — PROVIDE SLEEVE AT WALL FOR COIL DRAIN. SEE FS1A459 SODA SYSTEM 1/2 CONNECT WITH SOV, AND APPROVED TYPE RP BFP, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FS. ® ( 116 ) UNIT COOLER (COOLER) FS — 1 _ — — PROVIDE SLEEVE AT WALL FOR COIL DRAIN. SEE FS1A459 KITCHEN EQUIPMENT CONNECTION SCHEDULE EQUIP. NO. DESCRIPTION ROUGH —IN CONNECTION (IN REMARKS W V IW CW HW G ( 120 ) WATER FILTER — — — 1/2 — — USE WITH ITEM 121 ICE MAKER FS — 3/4 1/2 — — CONNECT WITH SOV, FILTERED WATER (120) AND RP BFP, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FS. ® ® ICE BIN FS — 1 — — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. ® FLOOR TROUGH Sc GRATE 3 2 — — — — PROVIDE DRAIN AND "P" TRAP. EXHAUST HOOD WATER WASH CABINET FS — 1 _ 2 — CONNECT 2" HW SUPPLY WITH SOV & OUTLET HEADER. PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. ( 130 ) COMBI—OVEN (DOUBLE) FS (2)3/4" CONNECT WITH SOV, FILTERED WATER (137) AND RP BFP, QUICK DISCONNECTS, INDIRECT DRAIN WITH 1" MIN. AIR GAP TO FS. ® HAND SINK W/ ELECTRONIC FAUCET 1 1/2 1 1/4 — 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ® ® WATER FILTER — — — 3/4 — USE WITH TEM 133 EXHAUST HOOD W/ MAKE UP FS — 2 — 1 — CONNECT 1" 140'F WATER FROM HOOD WASH SYSTEM PANEL TO WASH SOLENOID ASSEMBLY AND 2" CHROME PLATED DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. SEE 1/FS1A500 ( 146 ) CONVECTION OVEN (DOUBLE) — — — — — (2)3/4 PROVIDE P.C., DIRT LEG, QD & FLEX CONNECTION, 60 CFH EA. ( 150 ) (2) BURNER RANGE — 3/4 PROVIDE P.C., DIRT LEG, QD & FLEX CONNECTION, 60 CFH ® FILL FAUCET — — — 1/2 1/2 — ROUGH —IN AND FINAL CONNECTION ® KETTLE (40 GAL) — — — — — 3/4 PROVIDE P.C., DIRT LEG, QD & FLEX CONNECTION, 140 CFH ® FLOOR TROUGH & GRATE 3 2 — — — — FURNISH Sc INSTALL DRAIN AND "P" TRAP. HAND SINK W/ ELECTRONIC FAUCET 1 1/2 1 1/4 — 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ( 169 ) WORKTABLE W/ SINKS FS — 1 1/2 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ( 170 ) WORKTABLE W/ SINKS FS — 1 1/2 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ® HAND SINK W/ ELECTRONIC FAUCET 1 1/2 1 1/4 — 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, AND "P" TRAP. INSTALL FAUCET PROVIDED BY KEC. ROUGH —IN WITH TMV-1, SET AT 120'F ( 183 ) ( 184 ) SOILED DISHTABLE FS — 1 1/2 — — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. ( 186 ) PRE RINSE — — — 1/2 1/2 — ROUGH —IN AND CONNECTION CONVEYOR WARE WASHER W/ BOOSTER FS — 1 1/2 1/2 3/4 — PROVIDE 140 DEG. HW. CA DRAIN WITH TEMPERING KIT. PROVIDE VACUUM BREAKER AND LINE SIZE PRV AND SET TO 25 PSIG. ( 190 ) POT WASHING SYSTEM FS — (3) 2 (2)3/4 (2)3/4 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCETS PROVIDED BY KEC. MID WORKTABLE W/ SINK FS — 1 1/2 — — — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ( 198 ) ( 201 ) DRIP TROUGH FS — 1 1/2 — — — PROVIDE INDIRECT DRAIN TO FLOOR SINK WITH 1" MIN. AIR GAP. WORKTABLE W/ SINKS FS — 1 1/2 1/2 1/2 — PROVIDE SUPPLIES STOPS, DRAIN FITTING. CHROME PLATED TAILPIECE, ESCUTCHEON, P—TRAP & INDIRECT DRAIN TO FS WITH MIN. 1" AIR GAP. INSTALL FAUCET PROVIDED BY KEC. ( 210 ) NOTE: PLUMBING CONTRACTOR TO PROVIDE ROUGH —IN AND FINAL CONNECTION TO FOOD SERVICE EQUIPMENT SCHEDULED. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER 0 ISSUED FOR CONSTRUCTION 11.26.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYM REVISION BY APPROVED DATE SYM REVSION BY APPROVED DATE CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 e;LAMIE,AW. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN ON SAZAN DATE 11.20.13 SUAWI.E PLUMBING SCHEDULES CURRENT REVSION 12419164 SYMBOL 0.11E 11.26.13 INGINFEH CHECKED APPROVED APPROVED THE urrMAnurAl I/ACTCO BUILDING 09-94.1 All SHEET M2b JOB NO. 12419164 COMP NO. on/ CEIITCD WA DWG ND' no_non_En I, PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DESCRIPTION CONNECTIONS (INCHES) TYPE REMARKS SAN VENT HW CW P-1A WATER CLOSET 4 2 tYq WALL -HUNG, SIPHON JET, FIXTURE: AMERICAN STANDARD MODEL 2257.001, AFWALL, VITREOUS CHINA, 1.1-1.6 GPF, WALL MOUNTED, ELONGATED BOWL, FULLY GLAZED TRAPWAY, CONDENSATION CHANNEL, DIRECT FED SIPHON JET ACTION, 1 1/2° INLET SPUD, 2-1/8" TRAPWAY, 10"X12" WATER SURFACE AREA. ADA COMPLIANT. SUPPORT: ZURN 1203-N, ADJUSTABLE, HORIZONTAL SIPHON JET WATER CLOSET °RIGID SYSTEM" WITH 4-INCH NO -HUB CONNECTIONS. COMPLETE WITH DURA-COATED CAST IRON RIGHT HAND, LEFT HAND, OR DOUBLE MAIN FITTING, WITH 2-INCH VENT, ADJUSTABLE GASKETED FACEPLATE, UNIVERSAL FLOOR MOUNTED FOOT SUPPORTS, CORROSION RESISTANT ADJUSTABLE ABS COUPLING WITH INTEGRAL TEST CAP, FIXTURE BOLTS, TRIM, AND STUD PROTECTORS. REAR ANCHOR TIE DOWN AND BONDED "NEO-SEAL" GASKET. FLUSH VALVE: SLOAN UPPERCUT #WES-115, DUAL FLUSH - 1.6 GPF/1.1 GPF. DIAPHRAGM REPAIR KIT: WES 213, CODE #3372004. SEAT: CHURCH MODEL 9500C, OPEN FRONT, WHITE. REFER TO ARCHITECTURAL FOR MOUNTING HEIGHTS. P-3A LAVATORY 2 IX X Y UNDERCOUNTER AMERICAN STANDARD MODEL 9482.000. OVALYN UNIVERSAL ACCESS, VITREOUS CHINA, REAR OVERFLOW, 4" CENTERS, MOUNTING KIT, GRID STRAINER DRAIN FITTING. PROVIDE PREFORMED INSULATION ON SUPPLIES AND P-TRAP. FAUCET: DELTA COMMERCIAL 523LF-HDF, SINGLE HANDLE, 3-HOLE DECK MOUNT, CHROME PLATE FINISH, FLEXIBLE STAINLESS STEEL HOSES, METAL GRID STRAINER, VANDAL RESISTANT AERATOR, 0.5 GPM AT 60 PSI. P-5 MOP SINK 3 2 ) ,1 SERVICE SINK AMERICAN STANDARD FLORWELL SERVICE SINK 7741.000 FLAT GRID DRAIN 7721.038, RIM GUARD 7745.811 AND 8344.111 FAUCET WITH VACUUM BREAKER AND HOSE FD-2 FLOOR DRAIN 2 2 Y2 WORK AREAS FLOOR DRAIN JR SMITH 2120Y-B, 8" DIA. STRAINER, CAST IRON BODY, POLISHED NICKEL -BRONZE TOP, SEDIMENT BUCKET, W/ TRAP PRIMER CONNECTION. FD-3 FLOOR DRAIN 2 2 Y RESTROOM FLOOR DRAIN JR SMITH 2005HP NICKEL BRONZE 6" DIA. STRAINER, HEEL PROOF GRID W/ FLASHING COLLAR, W/ TRAP PRIMER CONNECTION FD-4 FLOOR DRAIN 2 2 - , HEAW DUTY JR SMITH 2121-Y GALVANIZED C.I., 8" DIAMETER EXTRA HEAW GRATE AND SEDIMENT BUCKET W/ TRAP PRIMER CONNECTION. SEE PLAN FOR SIZE. TPV-2 TRAP PRIMER VALVE Y MULTIPLE PRECISION PLUMBING PRODUCTS MODEL PR-500 WITH DU-3 DISTRIBUTION UNIT. RUN 1/2" SLOPED UNE TO EACH DRAIN TRAP. PROVIDE SS ACCESS PANEL. TPV-3 TRAP PRIMER VALVE Y SINGLE PRECISION PLUMBING PRODUCTS MODEL P2-500. RUN 1/2" SLOPED LINE TO DRAIN TRAP. PROVIDE STAINLESS STEEL (SS) ACCESS PANEL. FS-1 FLOOR SINK 2 2 - - FLUSH TO FLOOR. INSTALL HALF EXPOSED AT REFRIGERATION TOE KICKS. CECO 906-1-C, 12x12x6, WITH SEEPAGE FLANGE, 902 ALUMINUM DOME STRAINER, AND 912-2 HALF GRATE FS-2 FLOOR SINK 2 3 4 2 2 2 - - FLUSH TO FLOOR. INSTALL IN WORK AREAS. CECO 906-1-C, 12x12x6, WITH SEEPAGE FLANGE, 902 ALUMINUM DOME STRAINER, AND 912 HALF TOP GRATE WHA-1 WATER HAMMER ARRESTOR - J.R. SMITH MODEL 5005 INSTALL PER PDI RECOMMEDATION AT END OF BRANCH LINE SERVING BATTERY OF FIXTURES WITH QUICK ACTING VALVES AS PER UPC SECTION 609.10 NOTE: 1. TRAP SIZES SHALL BE DRAIN LINE SIZE. 2. PROVIDE TMV-2 FOR EACH P-3A. GREASE INTERCEPTOR SCHEDULE EQUIP. NO. SYSTEM OR AREA SERVED DWG, NO. LOCATION INLET SIZE (INCHES) OUTLET SIZE (INCHES) RATED FLOW (GPM) HOLDING CAPACITY (GALLONS) BASIS OF DESIGN REMARKS GI-1 KITCHEN UGM110 EXTERIOR 4 4 100 - ZURN Z1172-1000-41P 1, 2 NOTES: 1. ACID RESISTANT COATED FABRICATED STEEL. 2. ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL EXTENSION. C DIMENSION = 34" (FIELD VERIFY) DOMESTIC HOT WATER HEATER SCHEDULE MARK NUMBER INPUT RATING AGA-MBH TANK STORAGE GALLONS DELIVERY RATE FLUE SIZE INCHES MOTOR DATA BASIS OF DESIGN REMARKS CODE STAMP FIRST HR GAL 100' RISE RECOVERY GPM SERVICE HP KW 100'F RISE 80'F RISE HWG-1 399.9 130 ASME 557 466 - 4 - - - AO SMITH BTH-400A 1, 2 ST-1 - 80 ASME - - - - AO SMITH TJ-80A - NOTES: 1. PROVIDE WITH BTH-400-500 VENT KIT. P/N: 9006144005 2. ELECTRICAL 120V/1/60 GAS METER & REGULATOR SCHEDULE MARK NUMBER CAPACITY MBH INLET PRESSURE PSIG OUTLET PRESSURE IN. W.C. PRESSURE LOSS BASIS OF DESIGN REMARKS GM-1 2,800 8 8 - AMERICAN METER RPM-2M GR-1 2,800 5 8 - FISHER S202 VALVE SCHEDULE EQUIPMENT NUMBER LOCATION SERVICE SIZE MANUFACTURER MODEL FLOW (GPM)(PSI) ENTERING PRESSURE LEAVING PRESSURE (PSI) PRESS DROP (PSI) REMARKS PRV-1 - DOMESTIC WATER 1/2" WILKINS 500YSBR 5 60 55 5 WITH STRAINER AND ISOLATION VALVES RP-1 - DOMESTIC WATER 1/2" WILKINS 575XL 5 60 50 10 WITH STRAINER AND ISOLATION VALVES TMV-1 - DOMESTIC WATER 1/2" SYMMONS 5-120B 5 60 35 5 PROVI EECHECK VALVESCET ONNINLETS PUMP SCHEDULE MARK NO. SERVICE GPM HEAD FT H2O MOTOR BASIS OF DESIGN REMARKS HP RPM VOLTS PHASE HERTZ CP-1 DOMESTIC HOT WATER 3 13 1/25 1800 115 1 60 GRUNFOS UPS 15-42F BRONZE QUAING CONTRUCTION AQUA STAT & TIME CLOCK CP-2 DOMESTIC HOT WATER 5 20 1/12 3250 115 1 60 GRUNDFOS UP 26-64F PRONZE TEMPING CONTRUCTION TEMPERATURE CONTROLN EXPANSION TANK SCHEDULE EQUIPMENT NUMBER LOCATION TANK DESCRIPTION TYPE MANUFACTURER MODEL VOLUME (GAL) ACCEPTANCE VOL (GAL) PRESSURE DIA (IN) LENGTH (IN) REMARKS RATING (PSI) ET-1 MECH. PLATFORM EXPANSION AMTROL ST-12-C 6.4 3.2 125 12 20 INSTALL ON WHG-1 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER CONSTRUCTION NOTES NEW HWG-1 AND ST-1 TO REPLACE WITH EXISTING DOMESTIC HOT WATER GENERATOR. 0 ISSUED FOR CONSTRUCTION 11.26.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 • Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 Bf APPROVED DATE REVSION BY APPROVED DATE CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 ceLAYArEzAw. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN ON/S42AN DATE 11.20.13 SUBTITLE PLUMBING SCHEDULES CURRENT REVISION 12419164 SYMBOL DATE 11.26.13 cuE06ED APPROVED TIRE CAFETERIA UPGRADE BUILDING 09-94.1 SHEET M2c JOB NO. 12419164 COMP NO. APPROVED urrunnllrAM IIACTCD All nnl rrnlTrP WA °NG N0' n0_nOA-119. 2012 WASHINGTON STATE ENERGY CODE NOTES 1. LOAD CALCULATIONS SHALL BE PERFORMED PER ASHRAE STANDARD 183 OR CHAPTER 3 OF THE WASHINGTON STATE ENERGY CODE (WSEC) AS NOTED IN SECTION C403.2.1 OF THE WSEC. 2. THE OUTPUT CAPACITY OF HEATING AND COOLING EQUIPMENT AND STSIEMS DO NOT EXCEED EXCEED CALCULATED LOADS PER SECTION C403.2.2 OF THE WSEC. 3. MECHANICAL VENTILATION SHALL BE PROVIDED PER SECTION 401.2 OF THE INTERNATIONAL MECHANICAL CODE WITH FLOW REDUCTION CAPABILfIY TO THE CODE MINIMUM. 4. EACH HVAC SYSTEM WITH TOTAL FAN MOTOR NAMEPLATE HORSEPOWER EXCEEDING 5 HORSEPOWER SHALL MEET THE PROVISIONS OF SECTION C4032.10 OF THE WSEC. 5. NEW MECHANICAL SYSTEMS SHALL COMPLY WITH THE SYSTEM COMMISSIONING AND COMPLETION REQUIREMENTS PER SECTION C403.2.9 OF THE WSEC. 6. ZONE TEMPERATURE CONTROL SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5'F PER C403.2.4.2 OF THE WSEC. 7. THERMOSTATS SHALL BE 7 DAY PROGRAMMABLE WITH MANUAL OVERRIDE FOR TEMPORARY OPERATION UP TO 1W0 HOURS PER C4.3.2.4.3 OF THE WSEC. 8. ALL DUCT AND PIPING STSILMS SHALL BE INSULATED PER SECTION C403.2.7.2 k TABLE C403.2.8 OF THE WSEC. PROTECTION OF PIPE INSULATION EXPOSED TO WEATHER SHALL COMPLY WITH SECTION C403.2.8.1 OF THE WSEC. 9. AIR HANDLING STSIEMS SHALL HAVE OPTIMUM START CONTROLS PER SECTION C4.32.2.4.3.3 OF WSEC. 10. ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED PER SECTION C403.2.7.3, C402 LEAKAGE REQUIREMENTS AND INTERNATIONL BUILDING CODE VAPOR RETARDER REQUIREMENTS. 11. ALL LOW PRESSURE DUCT IEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6% OF THE FAN FLOW. 12. OUTSIDE AIR INTAKES AND EXHAUST DUCTS SERVING CONDITIONED SPACE SHALL BE EQUIPPED WITH MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN STSILM IS OFF OR UPON POWER FAILURE. DAMPER LEAKAGE RATE SHALL COMPLY WITH SECTION C402.4.5.2 OF THE WSEC. 13. ECONOMIZER HEATING STSILM IMPACT SHALL COMPLY WITH SECTION C403.1.4 OF THE WSEC. 14. INTEGRATED ECONOMIZER CONTROL SHALL COMPLY WITH SECTION C403.1.3 OF THE WSEC. PRESSURE CLASSIFICATION FOR DUCTWORK SCHEDULE TYPE DUCT PRESSURE CLASS REMARKS (IN. WG) (Pa) RETURN +1.0 250 SUPPLY (UPSTREAM OF VAV TERMINAL UNIT) +2.0 500 SUPPLY (DOWNSTREAM OF VAV TERMINAL UNIT) +1.0 250 EXHAUST +1.0/-1.0 250 REVIEWED FOR -CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION 0 RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER ISSUED FOR CONSTRUCTION 11.26.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 PENSION BY APPROVED COE SYM REV610N BY APPROVED DATE CAFETERIA UPGRADE 124191E4 SAZAN/ON 11.26.13 g)LAFL7EZAW® ACCEPTABILITY NIS DESIGN AND/OR SPEEDICATION IS APPROVED DRAWN ON SAZAN CHECKED DATE 11.20.13 SUBTIRE GENERAL NOTES CURRENT REVISON 12419164 SYMBOL DATE 11.26.13 APPROVED BY DEPT. DATE N4INEER CHECKED APPROVED APPROVED 117LE CAFETERIA UPGRADE BUILDING 09-94.1 urrunnurnl WACTCD AI SHEET M2d JOB N0. 12419164 COMP NO. nfl rcMTrD WA DWG BD. no_noA-LnA 1" VALVE & PRV SET 25 PSIG ON 140T RISER 1"0 140'F HW CW UP TO MEC SEE DWG. M450 FOR DIAGRAM AND PIPING ABOVEGROUND CAP 4" SOIL FINISH FLOOR 4"C.I REDUCE 3" C.I. TO 2Y" GALV. STL AT FLOOR 4"HWR c& 4" HWS-FRO BLDG. 9-96 SEE DWG. Y-201 NOTE: PIPING RUNS UNDER GRADE BEAM 3" CW (C.I.) SEE DWG. Y-103 FOR CON'T 2"R.D. BY 1"0 . ROOM II 4"F.S. I I NV. EL 12.45' INV. EL 12.3' APPROVED DATE r-INV. EL 12.4' 4" PLUGGED 4"F.S. \4"F.S. ./3 Y i'- -PLUGGED GED 11I C.O. 2"F.D. ]I " FROM D.F. UCE AT FLOOR L TO 3" 2" FROM SINK 4" SOIL FROM TOILET RMS O C.O. 10.-4 INV. EL 12.18' INV. EL 12.08' INV. EL 12.03' SAN INV. 11.81' BACKFLOW VALVE INV. EL 11.85' SYM REVS/ON GI-1 GREASE INTERCEPTOR IN VAULT INV. 11.85' $POCQ BY 0 APPROVED DINING AREA FFE = 16.00' 2" V UP 3" TO FS 3" TO FS 2" V UP 4" TO FS 2" V UP 2° V UP 2' UP TO FS 2FS,-1 3" UP WC (2) 2" V UP 2" TO HST 4 _14 FC9i 4" TO FCO 2" TO FD 4" TO FCO 2" TO INV. EL 12.74' DATE A DISHWASHER ROOM J#534170-00 M.WONG RWS 08.02.04 DISHWASHER ROOM. Rn #5 J1534170-00 M.WONG LAW FOR RWS 04.19.05 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 SERVERY AREA 2" TO FS -2" TO FD �I 2" TO 2"k_, 2" V UP 2" TO FD 4` —1.5% SLOPE 2"UPTOFp INV. EL .39' INV. EL 13.44' 4" UP TO FCO INV. 15.00' 2" TO FS i 2" TO FD-"' J' 3" UP rTO FCO t 2" TO FS 2" V UP 2" TO FS 2" TO FD 3" TO FS 3" TO FS O. (2"V (-YP.) 4" F.C.O. CAPPED 4" PARTIAL PLAN VIEW SCALE: 1/8" = 1'-0" O el_AirAFEAIAW ACCEPTABILITY THIS DESCH AND/OR SPECIOCATION IS APPROVED APPROVED BY DEPT. DATE INV. EL 10.98' DRAWN M.WONG CHECKED ANI.INW1 CHECKED DATE 05.24.04 INV. EL 10.9' INV. EL 13.29' 2" TO FS 1 1/2" V UP 2" V UP 3"TOT 2 V UP 2" V UP 2"WU 3" TO F 2"VUP 3" TO FS 2" TO FS 2"VUP 1 1/2" V UP 2"VUP 2" TO FD SUBTHIE INV. EL 10.66' SEE I CIVIL PLANSCKIN RMIT C N ER LOADING DOCK PIPING. T INV. E 10.4T INV. EL 9.5' REVIEWED FOR D�IANC APP12 D FEB 2 5 214 BUILD NG D64 I IS U 1\-IN✓- 10.2' LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. GENERAL NOTES 1. - REFERENCE DRAWINGS 109-094-4002-MC-102 PLUMBING PLANS AND ISOMETRIC WASTE & VENT 109-094-M507 ISOMETRIC DETAILS 109-094-1M454 KITCHEN AREA ENLARGED PLUMBING PLAN 109-094-1M455 KITCHEN AREA ENLARGED PLUMBING PLAN 109-094-1M456 SERVING AREA ENLARGED PLUMBING PLAN CONSTRUCTION NOTES PROVIDE NEW SEWER AND ASSOCIATED RISERS AS SHOWN. CONNECT NEW 4" SEWER LINE TO EXISTING 4" SEWER LINE. VERIFY INVERT ELEVATION PRIOR TO THE START OF ANY WORK. PROVIDE NEW 4" GREASE WASTE UNE. ® CONNECT NEW 3" ROOF DRAIN LINE TO EXISTING BELOW FLOOR. NEW GREASE INTECEPTOR. SEE GREASE INTERCEPTOR SCHEDULE. POC TO EXISTING STORM DRAIN BELOW FLOOR. PROVIDE NEW 4" SANITARY WASTE LINE. ® CONTRACTOR TO FIELD VERIFY EXISTING SEWER POINT OF CONNECTION PRIOR TO THE START OF ANY WORK DUE TO SHALLOW SITE SEWER LATERAL POC. NEW 2" SAN TO EXISTING. RECEIVED CITY OF TUKWILA FEB 1 3 2014 GROUP 600 Stewart St, Ste 1400 INV. EL 10.63' Seattle, Washington 98101 4" Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 PLUMBING PLAN - UNDERGROUND TITLE CAFETERIA UPGRADE BUILDING 09-94 11CruAAIIrol 11ACTCD rn1 All ISSUED FOR CONSTRUCTION 11.26.13 000 O 0 0 0 KEY PLAN 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CORREM REVISION 12419164 SYMBOL. C DAIS 11.26.13 UGM110 JOB N0. 12419164 COMP N0. nCV rrAITCD WA DWG N0' no_noA 1_ncul In C D E F G LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS MID & M1b. EXISTING HOW AND COLD WATER PIPING IN THIS R00 ABANDONED IN PLACE FOR FUTURE DEMOLITION. 2"FD (GROUT 4" HWS & R, 3/4" CA & 2 1/2" CW ABOVE SUSP'D CEILING SEE DWG C-202 OUTLINE OF MEC ROOM ABOVE BY UGGED JANITO 2" G UP. SEE M500 FOR CONT. 1" 140 DEG. HW & 1° pW DROP DOWN WALL AND RUN UNDER FLOOR TO DISHW(SHER 1" VALVE & PRV SET 2 PSIG IN 140 DEG. F RISER. 2"I CW c-3/4" HWC 2" HW 1 ENTRY SEE 1M454 CONTINUATIO WOMEN rEel APPROVED DATE SYM 1M110 1M454 UGGED HOSE REEL & 25' HOSE MOUNTED 4' ABOVE FLOOR SEE DWG. M450 FOR DIAGRAM & UGM110 PIPING UNDERGROUND 1 1/2" V DOWN. o C.O. 2"FS-2 QS 1M110 M504 SEE C/M450 FOR CONTINUATION. FOR FIRE RISER MEN PI WOMEN ELECTRICAL ROOM BY ------4H- FOR DINING AREA j TORAGE EMPLOYEE PARTIAL PLAN VIEW SCALE: 1/8" = 1'-0" APPROVED DATE A PURCHASE/INSTALL DISHWASHER J1794941-01 CFH 4.17.00 8 DISHWASHER ROOM J#534170-00 M.WONG RWS 08.02.04 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 r KITCHEN J COOLEi1 ceLAnur,ivc 3" UP TO GUTTER EN SERVERY FREEZER OFFICE JANITOR ®GAS METER, 5 PSI TO 8" WC REGULATOR GM-1 GR-1 1M1101M505 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN C. HARRAH "MELTED R1 INELR CHECKED APPROVED APPROVED STORAGE EWED FOR ^OMPLIANCE PROVED 252014 of Tukwila NG DIVISION 1M110 1M455 O GENERAL NOTES 1. - REFERENCE DRAWINGS 109-094-UGM110 109-094-1M454 109-094-1M455 109-094-M508 109-094-M509 109-094-M510 UNDERGROUND PLUMBING PLANS KITCHEN AREA ENLARGED PLUMBING PLAN KITCHEN AREA ENLARGED PLUMBING PLAN HOT AND COLD WATER DIAGRAM NATURAL GAS DIAGRAM WASTE AND VENT DIAGRAM CONSTRUCTION NOTES PROVIDE NEW COLD, HOT AND HOT WATER RETURN DOMESTIC WATER PIPING UP TO MECHANICAL PLATFORM LEVEL. PROVIDE NEW COLD, HOT AND HOT WATER RETURN DOMESTIC WATER PIPING AS SHOWN. PROVIDE NEW 2" G PROVIDE GAS METER, 5 PSI TO 8" WC REGULATOR AND LABELED SHUT-OFF VALVE. PROVIDE FLOOR SINK AND ASSOCIATED WASTE AND VENT PIPING. © PROVIDE NEW GAS UP TO MECHANICAL PLATFORM. POC NEW 3" TO EXISTING 3° RWL. ° RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER ISSUED FOR CONSTRUCTIO 11.26.13 DATE 4.17.00 SUBTITLE SAZAN GROUP 600 Stewart St., Ste 1400 e, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 PLUMBING PLAN - FIRST FLOOR T E CAFETERIA UPGRADE 1/Cr4! AAIIrAI 1JACT0O BUILDING 09-94 rnl All 000 0 0 0 0 44 KEY PLAN SGVF KTS 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-O" CURRENT REVISION 12419164 SYMBOL C DAZE 11.26.13 SHEET 1 M 1 1 0 JOB N0. 12419164 COMP N0. nrl rrAITrp WA' N0. n0_nOA_1'Alin 3" V.T.R. 1 3" V.T.R. PARTIAL PLAN VIEW SCALE: 1/8" = 1'-0" O [1-1 1/4" CD [1>-1 1/4" CD 1 1 /4"C 1 1 /4"C 1'3" 3" V.T.R. 1=3" V.T.R/ REVIEWED FOR C4DE_CQWLIANCE APPROVED FEB 2 5 2014 City of '' ilal BUILDING DIVISION v LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. GENERAL NOTES IT% EQUIPMENT AND ASSOCIATED DUCTWORK ABANDONED IN PLACE. RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERM! CENTER 2. — REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE NEW PLUMBING VENT EXISTING PLUMBING VENT TO REMAIN. 1 1/4" CD DOWN TO BELOW ROOF. CONNECT TO EQUIPMENT WITH 4" MINIMUM TRAP. SAZAN IS UED FOR CONSTRUCTION 11.26.13 GROUP 600 Stewart St., Ste 1400 e, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" Br APPROVED DATE SYM REVISION BY APPROVED 611E CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 BOE/HQ° o'— APPROVED BY ACCEPTABILITY THIS DESIGN MID/OR SPECIFICATION IS APPROVED DEPT. MATE ONDRA/N SAZPN i.'H CKED DATE 11.20.13 SUBRRE ROOF PLUMBING PLAN CURRENT REVISION 12419164 SYMBOL DATE 11.26.13 NCINELN APPROVED ETC CAFETERIA UPGRADE BUILDING 9-94.1 urruAANPAI EIACTCO rnI All 94EET RFM110 JOB NO. 12419164 COMP NO. n r DWG NO. n0_nnA_Im In REVISION c91 SEE 1M110 FOR CONTINUATION. 2" CW 2" HW 3/4" HWC 2" GAS ©3"R.D. y By APPROVED DUE SYM SEE 3 [3>POC 3" RD DN. POC (E) 1M454 M5071M454 M507 FOR PIPING ISOMETRICS THIS AREA. BY H HWC 3"FD-2 Q 2"FD-3 P-1A 0" P-3A P— 1A 2"FD-3 P-3A TPV-3 3"FS-2 3" V.T.R. HW HWC CW 1 G 1 1/2" CW 2" HW 3/4" HWC 2° GAS© 3" V.T.R. C TPV-2 7 0,..„,„..--2"R.D. UP [1!_>-1 1/2" CW H 2" HW 1>2"FS-2 (:)."------2"F.D. FROM PENTHOUSE ABOVE C 171 ) 2"FD-71Q5 1M454 II/-3" V.T.R. 191 ?- U 3" V.T.R. T M504 (r(P•) (2) WALL CLEAN SEE 1M454 M505 A APPROVED PARTIAL PLAN VIEW SCALE: 1/4° = 1.-0" DATE CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 2"D.S. SEE KITCHEN FQUIPMF1{T DRAWINGS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila 1M110 1M454N BUILDING DIVISION ce;LINFAIE,AW ACCEPTABILITY. THIS DESIGN AND/OR SPECIFICA11ON IS APPROVED APPROVED BY DIET. DATE DRAWN ON/SAZAN CHECKED GINELN ul Aw W M N CITY UTS. LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. KEC KITCHEN EQUIPMENT CONTRACTOR GENERAL NOTES 1. REFER TO KITCHEN EQUIPMENT CONSULTANT DRAWINGS FOR EXACT FLOOR DRAIN AND FLOOR SINK LOCATIONS IN KITCHEN AREA AND SERVERY AREAS. REFERENCE DRAWINGS 109-094—UGM110 UNDERGROUND PLUMBING PLANS 109-094-1M454 KITCHEN AREA ENLARGED PLUMBING PLAN 109-094-1M455 KITCHEN AREA ENLARGED PLUMBING PLAN 109-094—M508 HOT AND COLD WATER DIAGRAM 109-094—M509 NATURAL GAS DIAGRAM 109-094—M510 WASTE AND VENT DIAGRAM CONSTRUCTION NOTES PROVIDE NEW FLOOR SINK. NOT USED. PROVIDE NEW CONNECTION TO EXISTING ROOF DRAIN BELOW ROOF AND RE—ROUTE AS SHOWN. POC NEW 3" TO EXISTING 4" VENT THROUGH ROOF. PROVIDE NEW FLOOR DRAIN WITH DRAIN OUTLET AS SHOWN. © 1 1/2" CW & 3/4" HW DN. IN WALL BELOW FLOOR WITH BALL VALVES BEHIND ACCESS PANEL 06'-0" A.F.F. P> NOT USED. ® PROVIDE NEW WATER CLOSET INSTALLATION. PROVIDE NEW LAVATORY INSTALLATION. PROVIDE NEW PIPING AS SHOWN. ECEIu OF TWO/ILA FEB 1 3 2014 PERMIT CENTER IS UED FOR CONSTRUCTION 11.26.13 DATE 11.20.13 CHECKED APPROVED APPROVED SUBTITLE TIME SAZAN GROUP 600 Stewart St., Ste 1400 We, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 KITCHEN AREA ENLARGED PLUMBING PLAN CAFETERIA UPGRADE BUILDING 09-94 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION 12419164 SYMBOL DATE 11.26.13 SHEET 1 M454 JOB N0. 12419164 COMP N0. n r, ..r. r.r," �,,. DWG N0. LEGEND SEE 1M456 FOR CONTINUATION. WALL CLEANOUT. SEE 3 1M455 M505 REVISION ( 153) (150) [3>-2"FD-2 1" DOWN TO HOOD WASH SYSTEM. y^ 13"FS-1 HW (133) 1M455 M504 MP.) (146) � I :Tien! 1 1/2" CD 1 1/4" CD UP THROUGH ROOF 3"FS-2Q1 OUTLINE OF AHU ON ROOF r 2"FS-1Q1 W ( 198) I 1^jJr �. 2" HW DN. TO HOOD) / 2"FS 1 SEE 1M456 FOR CONTINUATION. 3 1M455 M504 WASH SYST€M 2_FD-2 RUN PIPING IN LOW WALL 3/4" CW & HW TO BELO FLOOR TPV-2 GHT WALE (130) 1 1/4" CD .F4_2Q OUTLINE OF AHU ON ROOF co 2"FS-2 Ql 121 1233 (31/2" DETERGENT LINES DOWN IN WALL CONNECT TO HOOD WASHDOWN PANEL. L__J En APPROVED DATE SEE KITCHEN EQUIPMENT DRAWINGS. SYM L J L SEE KITCHEN EQUIPMENT DRAWINGS. (3) 1/2" DETERGENT LINES 1 1/4" HW 1" HW cv- 1" CW 13 3" GAS POC 2" RWL UP .POC 2° RWL UP POCQ 3" RWL UP TO 3" R.D. 3" V.T.R. 2" V 2"FD-2 2"FS-1 (3) 1/2" DETERGENT LINES DOWN IN WALL CONNECT TO DETERGENT DISPENSER. PARTIAL PLAN VIEW SCALE: 1/4" = 1'-0" REVISION 1M11550 61 3 APPROVED DATE CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 TPV-3 P-5 — PROVIDE SLEEVE AT WALL FOR COOLER COIL ROUTING. a 3" RWL DOWN TO BELOW GRADE. SEE IM110 FOR CONTINUATION. �eoEi�rc® MATCH LINE 0 SEE SHEET 1M456 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN OA N/eu SAZ FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. KEC KITCHEN EQUIPMENT CONTRACTOR GENERAL NOTES 1. PROVIDE LINE SIZE WALL CLEANOUT AT THE BASE OF ALL RISERS SERVING FLAT VENTED FIXTURES. 2. COORDINATE ALL FLOOR SINK AND FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL AND KITCHEN DRAWINGS. REFERENCE DRAWINGS 109-094-UGM110 109-094-1M454 109-094-1M455 109-094-M508 109-094-M509 109-094-M510 UNDERGROUND PLUMBING PLANS KITCHEN AREA ENLARGED PLUMBING PLAN KITCHEN AREA ENLARGED PLUMBING PLAN HOT AND COLD WATER DIAGRAM NATURAL GAS DIAGRAM WASTE AND VENT DIAGRAM CONSTRUCTION NOTES PROVIDE NEW FLOOR SINK. PROVIDE NEW CW, HW, HWC AND GAS PIPING. PROVIDE NEW CONNECTION TO EXISTING ROOF DRAIN BELOW ROOF AND RE-ROUTE AS SHOWN. ® NEW 3" RWL DOWN IN WALL TO BELOW FLOOR. PROVIDE NEW FLOOR DRAIN WITH 2" DRAIN. HW & CW DN. IN WALL BELOW FLOOR WITH SHOUT -OFF VALVES BEHIND ACCESS PANEL ®2'-0" A.F.F. PROVIDE SOLENOID VALVE AND INTERLOCK WITH HOOD FIRE PROTECTION ANSUL SYSTEM. POC NEW 3/4" HW AND CW TO EXISTING EXTERIOR HYDRANT. CEIVED CITTOF TUKWILA FEB 1 3 2014 PERMIT CENTER IS UED FOR CONSTRUCTION 11.26.13 'DATE 11.20.13 SUBTITLE SAZAN GROUP 600 Stewart St., Ste 1400 ttle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SCALE: 1/8"=1'-0" 8' 4' 0 4' 8' 16' KITCHEN AREA ENLARGED PLUMBING PLAN CURRENT REN50N 12419164 SYMBOL DATE 11.26.13 INEEN CHECKED APPROVE) RDVED TTTLE CAFETERIA UPGRADE BUILDING 09-94 SHEET 1M455 JOB N0. 12419164 COMP N0. nn. ,.,. DWG NO. ne 0 REVISION MATCH LINE SEE SHEET 1M455 BY APPRCNED DALE ( 105 ) sYM SEE KITCHE EQUIPMENT ( 1os) 2" V DN.— SEE 1M454 FOR CONTINUATION. - REVISION 1 1/ PROVIDE SLE-Ems€-AT'WALL FOR COOLER COIL ROUTING. "FS-1 Q 2" V.T.R. 3" WCO SEE KITCHEN EQUIPMENT DRAWINGS. 2"FS- (ass ) GAS DN. 2" V. DN PARTIAL PLAN VIEW SCALE: 1/4" = 1'-0" 91 APPROVED 0 r r LJ 1/2" CW DN. 1/2" HW DN. 2" V. UP IN FURRED COLUMN. RUN PIPING _IN WALL TO SINK 1M456 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 1M11560 011E CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 2"FS-1 Q 3"FS-1 Q o- PV3 2" SS HOOD DRAIN TO FLOOR SINK. 1" 140 HW DN. TO HOOD WASHDOWN SEE WALL / 3 (TYP CLEANO)TS. 1M454 M505 �BOE/NG' cw HIV HWC (1_32) ( 052) (os4) 3" V.T.R. 030 045 2" HOOD WASH DOWN TO FLOOR SINK. 1" GAS HW DN. 1" 140 HW DN. TO HOOD IN CHASE 1/2° TRAP PRIMER BELOW FLOOR. (TYP.) (T(P.) 1M456 M504—2"FD-2 3" V.T.R. 2" WCO 2" V. DN TPV-3 1 1/2" V. DN 1" CW II I 1" HW 3/4" HWC 1 1/2" GAS 1" HW (HOOD WASH) ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN ON SAZAN 2"FS-2 1 12"FD-i 3"FSy 1 1M456 M504 3/4" CW DN. 1 1/2" V. DN. 2" V. DN. 2" V. DN. LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. F.D.-FLOOR DRAIN FU.D-FUNNEL DRAIN VTR -VENT THROUGH ROOF KEC KITCHEN EQUIPMENT CONTRACTOR 2" V. UP FROM BELOW FLOOR WITH CO AT BASE OF RISER 1 1/2" V DN. (2) 2" V. DN. 1/2" CW DN. 1/2" HW DN. WALL CLEANOUT. SEE 3 1M455 M505 TYP. 1 1/2" V. DN. 3/4" CW DN. 3/4" HW DN. 2" V. UP FROM BELOW FLOOR WITH CO AT BASE OF RISE 1/2" HW & 1/2" CW DN. 1 1/2" V. UP 2"FS-1 Q TPV-2 2"FD-2Q POCQS 3" RWL DN. 1 1/4" GAS DOWN TO 064, 188 CFH POCQS 3" RWL UP TO 3" RD ON ROOF IS UED FOR 6ONSTRUCTION 11.26.13 1E 11.20.13 2NWNEEN CHECKED APPROVED APPROVED GENERAL NOTES 1. PROVIDE LINE SIZE WALL CLEANOUT AT THE BASE OF ALL RISERS SERVING FLAT VENTED FIXTURES. 2. COORDINATE ALL FLOOR SINK AND FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL AND KFTCHEN DRAWINGS. REFERENCE DRAWINGS 109-094-UGM110 UNDERGROUND PLUMBING PLANS 109-094-M507 ISOMETRIC DETAILS CONSTRUCTION NOTES • PROVIDE NEW PIPING AS SHOWN. PROVIDE NEW FLOOR SINK AS SHOWN. PROVIDE NEW FLOOR DRAIN AS SHOWN. ® PROVIDE NEW TRENCH DRAIN AS SHOWN. • PROVIDE NEW CONNECTION TO EXISTING ROOF DRAIN BELOW ROOF AND RE-ROUTE AS SHOWN. • PROVIDE SOLENOID VALVE AND INTERLOCK WITH HOOD FIRE PROTECTION ANSUL SYSTEM. NEW ROOF DRAIN PIPING RE-ROUTE TO ACCOMMODATE NEW DUCTWORK. RECEIVED CITY OF TUKWILA FEB 1 3 2014 ERMIT CEN SAZAN GROUP 600 Stewart St, Ste 1400 e, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SCALE: 1/8"=1'-0" 8' 4' 0 4' 8' 16' SERVING AREA ENLARGED PLUMBING PLAN TrRE CAFETERIA UPGRADE IlrrIJ AAIN`AI ll ACTCD BUILDING 09-94.1 CURRENT REV190N 12419164 SYMBOL DATE 11.26.13 SHEET 1M456 JOB N0. 12419164 COMP N0. AI I n0V rrA1TCD um DWG BO' no_nOA-11IA RR CC487C: 06/12/ AUTO AIR VENT 0 HIGH PT. CP-2 CP-4 CH-1 DRAIN CH-2 ACCESS DOO 4- CLEANOUT ST000R VENT 4" VENT UP TO MECH. PLATFORM-�� CAP CAP 4" HWS &HWR FROM THE 9-98 BUILDING, 100 GPM WATER PIPING DIAGRAM SCALE: 1/4"=1.-0" M5001M450 2 CONDENSATE DRAIN SUPRESSOR, AMTROL 537 ABOVE GRADE ABOVE GRADE SANITARY & AIR VENT n DOMESTIC HOT & COLD WATER(-b- SCALE: 1 /4"=1'-0" SCALE: 1/4"=1'-0" UGM110, 1M110 M450 1M110 M450 PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DESCRIPTION CONNECTIONS (INCHES) TYPE REMARKS SAN VENT HW CW P-1 WATER CLOSET 4 2 1 Ya WALL -HUNG, SIPHON JET, SLOAN #111 FLUSH VALVE AMERICAN STANDARD AFWALL MODEL 2257.103 WITH WADE 310ND & 310NL, 4" NO HUB CARRIER P-2 URINAL 2 2 - Y WALL -HUNG, SIPHON JET, SLOAN #8186-1.0 FLUSH VALVE AMERICAN STANDARD TRIMBROOK MODEL 6561.017 WITH WADE 420, 4" NO HUB CARRIER P-3 LAVATORY 2 2 Y Y COUNTERTOP KOHLER INVITATION K-2098 AND SLOAN ETF-700 ELECTRONIC GOOSENECK P-4 SERVICE SINK 3 2 Y Y SERVICE SINK AMERICAN STANDARD FLORWELL SERVICE SINK 7741.000 FLAT GRID DRAIN 7721.038, RIM GUARD 7745.811 FD-1 FLOOR DRAIN 2 2 - Y 2" 0 WITH TRAP & 1/2" TRAP PRIMER WADE 1122NH-G6-1 TPV-1 TRAP PRIMER VALVE - Y PRECISION PLUMBING PRODUCTS MODEL PR-500 WITH DU-3 DISTRIBUTION UNIT SYM ER APPROVED DATE SYM REWBON Br APPROVED DATE co !?Z.S/NK 172 CO P-4 1%D. (C#007) ISOMETRIC WASTE & VENT PIPING DIAGRAM SCALE: NONE M450 pod' To D N' JA0UM op tlsIII p11 TRD DI yM c° to- n= nE rOK pro %_ a�2 / 1\i Is TE UR / -�\i• y' ..II UOSE REi1 A 9-94 DISHWASHER ROOM J#534170-00 M.WONG RWS 08.02.04 9-94 AHU UPGRADE 534907-01 RWS RWS 02.07.05 C CAFETERIA A/V UPGRADE 150637-02 M.WONG RWS 09.25.06 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 g)i__ArAwAvc. ISOMETRIC HOT & COLD WATER PIPING DIAGRAM SCALE: NONE M450 ACCEPTABILITY THIS DESIGN AND/OR SPEEIRCA11oN IS APPROVED APPROVED eY DEPT. DATE DRAWN M.WONG HA,KLU DATE 05.24.04 SUBTITLE 2 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila -.,; —.BUILDING DIVISION 'moo oV' �. �, �4 y. I; I 2 �n IP hiiih P.D.G. h • 2 .4 i.� i; ' "' #I.G C� VP.0.0 O 2 0 /1 6vq13 CONSTRUCTION NOTES P.O.C. CONNECT NEW HOT & COLD WATER TO EXISTING HOT & COLD WATER LINES TO RESTROOMS WITH BALL VALVES. PROVIDE NEW COLD, HOT AND HOT WATER RETURN DOMESTIC WATER PIPING AS SHOWN. PROVIDE NEW 1/2" COLD WATER PIPING DOWN IN WALL. ® POC NEW 1 1/2" VENT PIPING TO EJ(SRING 4" VENT. R URRRE 1 N (� %U 1� ' RECEIVED I DRFultITY OF TUKWILA 2rt.D FEB 13 2014 PERMIT CENTER ISSUED FOR CONSTRUCTION 11.26.13 ISOMETRIC WASTE & VENT CURRENT REVISION 12419164 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYMBOL D DATE 11.26.13 CHECKED APPRORD MPROYED TITLE CAFETERIA UPGRADE BUILDING 09-94 MrNJAADrAl MACTro /`n1 v_v /v_v SNEET M450 JOB NO. 12419164 COMP NO. nn, rrkirra WA DWG NO. no_noA—IAA an AGEHRKE 1/15/20 LEGEND id —EF-1, 2,850CFM ® 0.6"S 1yHP, GREENHECK SWB-213-15 11> 3/4" HWC, 2" CW, "HW DOWN. SEE 1M110 FOR CONTINUATION 1-1/2° HWS&R TO BOOSTER COIL 4" HWR & HWS DOWN FROM 9 96 CP-1 1 t3 HWR ®2" 2�2" CW - "T 2"HW HATCH SEE M500 M505 FOR PIPING INSTALLATION 2 1/2"CW MAIN \--P.R.V. SET ® 45 PSI 3'X10' RA OPENING 2" GAS, 1 1/2" HWS/R. SUPPORT WITH UNISTRUT SYSTEM ON WALL I r4" AIR VENT THRU. ROOF NG. W 1 1/2" HWS/R DOT / SEE 1M60 FOR CONTINUATION 2" GAS DOWN TO ABOVE 1ST LEVEL CEILING. SEE 1M11 FOR CONTINUATION. 1.4 48"Wx42"H DOOR O -03 MECHANICAL EQUIPMENT ROOM SCALE: 1/4" = 1'-0" RFM10 M500 Err APPROVED DATE SYM REVISION C6 By APPROVED DATE A 9-94 DISHWASHER ROOM Jj534170-00 M.WONG RWS 08.02.04 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 ce;L_ArArisw. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED 85 DEPT. DATE DRAWN EDDIE P. DUARTE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION DATE 05.28.04 RFL9NEth CHECKED sUBRRE c FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M10 & M1b. GENERAL NOTES 1 > EQUIPMENT AND ASSOCIATED DUCTWORK ABANDONED IN PLACE. 1. - REFERENCE DRAWINGS CONSTRUCTION NOTES P.O.C. PROVIDE NEW 2" CONNECTION TO EXISTING 2 1/2" DCW AT PRESSURE REDUCING ASSEMBLY. PROVIDE NEW 2" CW SUPPLY TO WATER HEATER. PROVIDE NEW GAS FIRE WATER HEATER AND STORAGE TANK PER SCHEDULE. PROVIDE NEW 2" GAS LINE. SUPPORT WITH UNISTRUT AT MECHANICAL ROOM WALL RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER ISSUED FOR CONSTRUCTION 11.26.13 MECHANICAL EQUIPMENT ROOM DETAIL TTT'E CAFETERIA UPGRADE urruOMlrAI 11ACTCD BUILDING 09-94.2 SAZAN GROUP 600 Stewart St, Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 CURRENT REVIS0* 12419164 SYM90L B DATE 11.26.13 sN¢r M500 JOB N0. 12419164 COMP NO. rnl o_r /1 o_ s F nn/ rrkuTCD wA DWG ND. no_noA_usnn AGEHRKE 1/15/2013 4 SEE COIL CONNECTION DETAIL 12"0 UP TO EF M501 RANSITION PIECE 'ROM AHU OUTLET ,IZE 97"x80" 0 97"x36" COOLING COILS (FURNISHED BY BOEING) 200 CFM (TYP 3 PLACES)` ROOF—. 1/4 36/24 2'x2' ACCESS DOOR 2" PAN DRAIN HOUSING OF 2"x2"x1/4" L & 20GA. GALV. SHEET METAL. DOORS SHALL BE GASKETFED AIR- 11GHT. CAILK BETWEEN BOTTOM ANGLE & FLOOR IN-ERMEDIATE S1 DRAIN PAN Si OPE 2 PAN 2" CONDENSATE DRAIN - 0 UI11rr1 tl,UrvuIU111 Ury MLA 11 Ununca UMNIMM ,) 6" CHWS w--1" SS DRAIN TO LOWER 8 PAN I18 GA SS DRAIN PAN DEEP SEAL P-TRAP (6" MINIMUM WATER SEAL) M501 M502 FANW (FURL 24°x4" REG. SR-1 150 cfm (6 REQ'D) LL SYSTEM ISHED BY BOEING COOLING COILS (FURNISHED BY BOEING) 4" HWR & HWS© FROM 9-96 2 1/2"CW MAIN 7/6 1 1/2° HWR 1 1/2" HWS 120"x42" WESTHERPROOF O.A. INTAKE LOUVER. - \''''''---24X96 MOTOR OPERATED RA. DAMPER IN TOT. OF DUCT. MECHANICAL EQUIPMENT ROOM 1 SCALE: 3/8"=1'-0" FANWALL SYSTEM (FURNISHED BY BOEING) BLANK OFF ALLAROUND UPSTREAM SIDE OF FANWALL 24"x95"MOTOR OPERATED • RETURN DAMPER 6" CONC. PAD 3" HWS 3" HWR 2-1/2" 3-WAY DIVERTING VALVE BELIMO G765D Cv=6R ,---SUSPENDED CEILING 9' ABOVE FLOOR 3'-0"x10'-0" OPENING THRU FLOOR WITH 1" MESH SCREEN IN 1"x1"x 1/8" L FRAME SECTION (TA - - SCALE: 3/8" = 1-0" M501 M50y 02 42"x17" CONCRETE PAD M500 M501 3" HWS&R C. 4" HWS&R 2-1/2" CW 2" HWS BOOSTER COIL CA-2 HATCH OPNG. 48"Wx42"H 1-1/2"HWR TO WATER HEATER. SEE SHEET M450 1-1/2" HWS 1-1/2" 2" HWR 3" GA. VA. 4" GA. VA. 4" HWR .� 4" HWS FOR PENTHOUSE HWS&R PIPING SEE ALSO HEATING HOT WATER ISOMETRIC PIPING DETAIL/ 1 M501 M502 1.4 DOWN TO UNDER- LOOR SUPPLY DUCT 20"x17" EXHAUST FROM DISHWASHER & TOILET ROOMS. ''"-----18"x24" WEATHERPROOF LOUVER. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION 18/50 LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M10 & M1b. GENERAL NOTES I 1 > COOLING COIL (2) EA: MODEL 5WS0806B, GROWS, 8 FINS/IN. 16,350 CFM, 599,790 BTUH, 413,315 BTUH SENS, COIL PRESS DROP: 0.62 FT EAT: db/wb 78.0/66.0, LAT: db/wb 54.9/53.9 EWF: 45 DEG. F., LWT: 55 DEG, F., 119.5 GPM, 18.2 FT HD 12 > 32700 HUNTAIR FAN WALL WITH (9) FAMS, 24.95 BHP (TOTAL), 2.77 OPERATING BHP (PER FAN), 18" WHEEL SIZE, 1975 RPM, 3.93" W.C. PEAK SP. 7' EQUIPMENT AND ASSOCIATED DUCTWORK ABANDONED IN PLACE. REFERENCE DRAWINGS FOR PENTHOUSE HWS&R PIPING SEE ALSO HEATING HOT WATER ISOMETRIC PIPING DETAIL M501 M502 CONSTRUCTION NOTES 12> PROVIDE 3" BUTTERFLY ISOLATION VALVES. PROVIDE NEW 3" HOT TAP BRANCHES TO EXISTING 6" CHWS & CHWR. PROVIDE NEW 2" HWS AND HWR CONNECTION TO EXISTING CAPPED 3" HWS & HWR. POC. NEW 2 1/2" CW TO EXISTING 2 1/2" AT PRV OULET. RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER SAZAN ISSUED FOR CONSTRUCTION 11.26.13 GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYM BY APPROVED DATE SYM REVB1011 85 APPROVED DATE A 9-94 AHU UPGRADE 534907-01 RWS RWS 02.08.05 9-94 UPGRADE- HEATING VALVE 534907-01 RWS RWS 08.04.05 9-94 UPGRADE-THERMOMEEERS/T-SENSOR 534907-01 RWS RWS 08.08.05 REPLACED HWSkR PIPING RISERS 534907-00 RWS RWS 09.29.05 PoPL IVRIA I Ior0ADF 11A101RA CUA11/AN LBOE//V6® ACCEPTABILITY THIS DESIGN AND/OR SPE0FlCA110N IS APPROVED APPROVED BY DEPT. DATE -DRAWN EDDIE P. DUARTE DATE 12.28.04 CHECKED SUBTME MECHANICAL EQUIPMENT ROOM DETAIL & SECTION IDLE CAFETERIA UPGRADE 11rru AAllrAI IIACTCD BUILDING 09-94.1 rem v_v /v_v CURRENT REVISION 12419164 SYMBOL E DAZE 11.26.13 SHEET M501 JOB N0. 12419164 COMP NO. E1N CEAITCD WA DWG, NO' 1107n0n-114n1 2 1/2" UNION - 3" H.W.R. 1/2" DRAIN VAL AUTO AIR VENT 4"x24 150 SYM _ 10'-0" x 3'-0" EXH. & REUEF DAMPER 0 t 18418 A A. 1 WHG-1 p--PLATFORM 1-:4 — ST-1 I HATCH COVER OPEN --c? I 1 I TRANSITION PC. FROM FAN OUTLET TO 18"x18" �SUSP'D CEILING 9'-0" ABOVE FLR. SECTION SCALE: 3/8" = 1'-0" M501 M502 /\ 36// /E 4 r',.II r HEATING COIL I 2 ' REG II 4 HW' �n II fm Ho 1 4" HWS. HEATING COIL 1/t:.II r III REVISION SECTION SCALE: 3/8" = 1'-0" 81 APPROVED M501 M502 DATE SYM I. 2"x36" R.A. GRILLE 1 G-1 2950 cfm AL / / 36/24 11 5/36 = M 0 8"x22" T0X?036... 36"x` 3" HWS 4" HWS&R FROM 9-96 UP THROUGH MECH RM FLOOR CIRCUIT SETTER BALANCING VALVE (TYP) Err APPRMED DATE x\4S A 9-94 AHU UPGRADE 534907-01 RWS RWS 02.09.05 8 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 SCALE: NO SCALE SECTION SCALE: 3/8" = 1'-0" M501 502 2" HWS 2" HWR HER 3" HWR 3" HWS 2 1/2" 3-WAY DIVERTING VALVE BELIMO G765D Cv=68 3" HWS&R TO MAIN AHU HEATING COILS CAPPED CAPPED y�R HEATING HOT WATER ISOMETRIC PIPING DETAIL rTh M501 M502 g;LAN7EA/AW. ACCEPTABILITY THIS OESCN AND/OR SPECIFlCATION IS APPROVED APPROVED BY DEPT. DRAWN EDDIE P. DUARTE OAT! 01.04.05 DATE CHECKED SUBNRE 3" 2-WAY BELIMO G680 ELECTRONICL FLANGED CHILLED WATER CONTROL VALVE, Cv=90 AAV 4 " CHWR 6" CHWR 4" CHWR 6" CHWS 2-1/2" (TYPICAL COIL CONNECTION) 4" CHWS 3/4" PLUGED LOW POINT DRAIN VALVE (TYP) DIELECTRIC UNION (TYPICAL 4 PLACES) COIL CONNECTION DETAIL( SCALE: NTS M501 M502 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER SAZAN ISSUED FOR CONSTRUCTION 11.26.13 MECHANICAL EQUIPMENT ROOM SECTIONS TITLE CAFETERIA UPGRADE BUILDING 09-94.1 11CrunkllrAl 1UCTCO CAI v_v /v_v GROUP 600 Stewart St, Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 CURRENT REVISION 12419164 SYMBOL B DATE 11.26.13 SHEET M502 JOB N0. 12419164 COMP N0. nN rcnlTVD WA DWG N0' n0_nQA_IKn9 10"WF 49 COLUMN 3"x8'-0" LINEAR DIFFUSER WITH OPP. BLADE VOL. DAMPER 800 CFM SR-3 FIN. FLOOR 111 ENCASE SUPPLY DUCT WITH CONC. MIN. 4" THICK SECTION 3"x8'-0" S.M. BRANCH TO EACH FL. REGISTER GRADE A SCALE: 1/2" = 1'-0" REVISION 1M10 M503 18"x50" SUPPLY DUCT TILE ENCLOSURE FIN. FLOOR CONC. BLOCK PLENUM 32"0 SUPPLY NEAR SIDE E�QMMEN �` 'IIIIIIIIIMEZ. LIM Ng MI LIMMMIN SECTION SCALE: 1/2" = 1'-0" `SUSPENDED CEILING 8/20 SUPPLY DROPS DOWN INTO JOIST SPACE STEEL ROOF DECK 1M10 M503 AHRE5 rAIR HANDLER 42/24 SUPPLf,,:s. 16" CURB 8/20 SUPPLY % `SD-2, 800 CFM SECTION SECTION SCALE: 1/2" = 1'-0" BY APPROVED DAZE 1M451 M503 REVISION BY APPROVED DATE A CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 SECTION SCALE: 1/2" = 1'-0" 16/16 SUSPENDED CEILING PIZZA OVEN HOOD BY KITCHEN EQUIPMENT CONTRACTOR SCALE: 1/2" = 1.-0 1M451 M503 1,Bt7.E.IAfG' o'- r.18/24 SUPPLY I 1M41 M503 -STEEL ROOF DECK n� '-SUSPENDED CEILING 8/20 SUPPLY DROPS DOWN INTO JOIST SPACE 10/20 ELBOW CONNECTS TO EXIST. 10/20 DUC 3'-0"x3'-0" EXHAUST HOOD POSITIONED OVER OUTLET OF DISHWASHER SEE DETAIL /� STEEL ROOF ACCEPTABILITY THIS DESIGN AND/OR SPECIFlG110N IS APPROVED APPROVED BY DEPT. DATE M503 DRAWN EDDIE P. DUARTE DATE 01.139.05 1350 CFM SUBTITLE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION EF-8 SECTION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER NOT USED SCALE: 1" = 1'-0" M503 17/20 20/8 DN TO EXIST. GRILLE SCALE: 1/4" = 1'-0" 20/20 20/16 1M10 M503 EF 7 ISSUED FOR CONSTRUCTION 11.26.13 SECTIONS & DETAILS FAN EF-1 20/17 TO NEW SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 COMM REVSI0N 12419164 SYMBOL A DATE 11.26.13 AN.INLLk R. SQUIRES 2HECKLD APPROVED 01.09.05 TTE CAFETERIA UPGRADE BUILDING 09-94.1 AlrruAAIV`AI WACTCP CAI _ SHEET M503 JOB N0. 12419164 COMP N0. nr\I rrKlrra WA DWG N0' n0-n0A_\/5ni RP-1 REDUCED PRESSURE BACKFLOW PREVENTOR STRAINER (TYP.) PIPE DRAIN TO F.S. FLOOR SINK INDUSTRIAL COLD WATER PIPING DIAGRAM SCALE: NONE DISHWASHER BY KEC DISHWASHER DRAIN LINE TO SANITARY SEWER DISHWASHER PIPING DETAIL SCALE: NONE REVLRION BY APPROVED DAZE SYM PRV-1 PRESSURE REDUCING VALVE (SET ® 15 PSI) PRESS. GAUGE ICW WATER TO EQUIPMENT SOV (TYP.) UNION (TYP.) FLOOR LINE 1M110, 1M454, 1M456 M504 CONNECT WITH WATER HAMMER ARRESTOR AND VACUUM BREAKER. SUPPLY LINE FROM BOOSTER TO DISH WASHER BALL VALVE 14 3/4" HW SUPPLY - ELECTRIC BOOSTER POP -OFF UNE. DRAIN TO FLOOR SINK 1M454 M504 FINISHED FLOOR RP-1 REDUCED PRESSURE BACKFLOW PREVENTOR STRAINER (TYP.) PIPE DRAIN TO F.S. FILTERED WATER PIPING DIAGRAM SCALE: NONE SANITARY 1 FLOOR SINK COLD WATER LINE TPV-1, TRAP PRIMER DISTRIBUTION BOX NOTE: PROVIDE TRAP PRIMER AND ACCESS PANEL AS REQUIRED FOR ALL FLOOR DRAINS. TRAP PRIMER INSTALLATION n SCALE: NONE APPROVED DATE A ADD DRIP LEG TO DRY SYS INSP TEST 5632960 HARR RWS 01/11/05 8 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 1M454 M504 1M45� 1M456 WATER FILTER SEE KITCHEN EQUIPMENT DRAWINGS. 1/2" FILTERED WATER TO EQUIPMENT SOV (TYP.) UNION (TYP.) FLOOR LINE 1M456 M504 PROVIDE MIN. 8"X8" SS ACCESS DOOR OR PANEL TO OTHER FLOOR DRAIN OR FLOOR SINK ACCEPTABILITY TNIS DESIGN AND/OR SPECIRCAION IS APPROVED EXISTING HOLE IN CONCRETE WALL w cc REINSTALL SPRINKLER ORIFICE GROUND REINSTALL EXISTING VALVE REPLACE EXISTING BLK STL PIPE W/ GALV. PIPE & FTGS REPLACE EXISTING ELBOW WITH TEE 1" SHORT NIPPLE TYP 1" VALVE 2" PIPE NIPPLE 1" VALVE, PLUGGED, 90 DEG EL FLOOR OF LOADING DOCK DRY SYSTEM INSPECTORS' TEST & DRAIN/DRIP LEG, LOOKING WEST n SCALE: 3/4" = 1'-0" APPROVED BY DEPT. DATE bR8wN EDDIE P. DUARTE DATE 01.19.05 CHECKED 1M260 M504 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION SUBTITLE LEGEND GENERAL NOTES 1. VALVES TO BE U.L. & F.M. APPROVED. STOCKHAM B-133 200# BRONZE RISING STEM GATE VALVE OR APPROVED EQUAL. 2. PIPING TO BE SCH. 40 GALV. WITH 125# GALV. C.I. FITTINGS U.L. & F.M. APPROVED. REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER O ISSUED FOR CONSTRUCTIO 11.26.13 SECTIONS & DETAILS VILE CAFETERIA UPGRADE BUILDING 09-94 urrun"Nroi unooro rn1 _ SAZAN GROUP 600 Stewart St, Ste 1400 CURRENT REVISION 12419164 ttle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYMBOL B 081E 11.26.13 SHEET M504 JOB N0. 12419164 COMP N0. nr,T rrurro WA DWG "0' no—non—uSnAP HOT WATER TO FIXTURES NOTE: 1. THE TEMPERATURE AND PRESSURE RELIEF VALVE SETTING SHALL NOT EXCEED PRESSURE RATING OF ANY ANY COMPONENT IN THE SYSTEM. �G�61 2" f 6" DIRT TRAP HIV PIPET &PTO OPEN DRAIN 2"1 2— CIRCULATION PUMP CP-2 rEFO a 0 2. SERVICE VALVES ARE SHOWN FOR SERVICING UNIT. HOWEVER, LOCAL CODES SHALL GOVERN THEIR USAGE. 3. THE TANK TEMPERATURE CONTROL SHOULD BE WIRED TO AND CONTROL THE PUMP BETWEEN THE WATER HEATER(S) AND THE STORAGE TANK(S). 4. THE WATER HEATER'S OPERATING THERMOSTAT SHOULD BE SET 5 DEGREES F HIGHER THAN THE TANK TEMPERATURE CONTROL. TANK 3/4" TEMPERATURE , 1* CONTROL b J j rALT. COLD WATER CONNECTION MECHANICALPIAFORM FLOOR I I ® I$ _ , I`'I I r'L/) I— L �4 J REVISION 2" 3/4 / CIRCULATION PUMP, CP-1 LINE TEMPERATURE CONTROL I HOT WATER RETURN COLD WATER SUPPLY 3 EXPANSION TANK EXISTING FLOOR SINK DOMESTIC WATER HEATING PIPING DETAIL SCALE: NONE SHALLOW CHROME WALLCOVER AND SCREW f M500 M505 MAY EXTEND AS A WASTE OR VENT. STAINLESS STEEL BANDS PLUGGED TEE WITH CLEANOUT WALL STAINLESS STEEL BANDS FLOOR LINE WALL CLEANOUT DETAIL SCALE: NONE B1 APPROVED DATE • 30-300T (TYP.) 0-100 PSI W/ SNUBBER (TYP) AAV BALANCING VALVE CONTROL VALVE • BALANCING VALVE Y STRAINER 3 \ LOW POINT SYM 1/8 BEND BALANCE OF PIPING SAME AS CLEANOUT TO GRADE 3 1M456 M505 1M455 1M454 BY APPROVED ISOLATION VALVE HOT WATER COIL CONNECTION DIAGRAM SCALE: NONE DATE A CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 Q,BOE/N�' o� 4 RF 60 M 05 ROTARY GAS METER BUILDING INLET SEE SHHET 1M110 FLOW INTEGRATOR SUPPORT LEG STRAINER 20 MESH GAS PRESSURE REGULATOR 5 LBS. TO 8" W.C. 2000 CFH DEMAND PLUG VALVE POC SEE CIVIL PLANS FOR 5=j CONTINUATION GAS METER PIPING DETAIL 2 0-100T (TYP.) 0-100 PSI W/ SNUBBER ( ) AAV CHWR ►-D4-------- CHWS AAV ISOLATION VALVE SCALE: NONE Y STRAINER LOW POINT BALANCING VALVE CONTROL VALVE CHILLED WATER COIL CONNECTION DIAGRAM 5 SCALE: NONE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN EDDIE P. DUARTE DATE 01.22.05 RFM60 M505 O 1M110 M505 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER SAZAN ISSUED FOR CONSTRUCTION 11.26.13 SECTIONS & DETAILS GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 CURRENT REVISION 12419164 SYMBOL' A wE 11.26.13 CHECKED APPROVED APPROVED TRIE CAFETERIA UPGRADE BUILDING 09-94.1 SHEEP M505 JOB N0. 12419164 COMP N0. 11N r0MT00 .UJA DWG Na (10-l10A-11F/10 11CruAAllcAl IIACTCD Al I • �S GAS i�p11. oFo 3/4 iVE ) (1P) (5 ( EOTIA w oLo "ILE ( I •/ l p5E 3co��ECTIoNION ( 3/4 VALVE ISOMETRIC HOSE CONNECTION DETAIL SCALE: NONE 2 1M455 M507 REVIEWED FOR CODAPPRCV�dNCE FEB 2 5 2014 City of Tukwila BUILDING DIVISION LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. GENERAL NOTES REFERENCE DRAWINGS 109-094—UGM110 UNDERGROUND PLUMBING PLANS 109-094-1M452 SERVING AREA PLUMBING PLAN CONSTRUCTION NOTES 11> POC NEW 3/4" HW & 3/4" CW TO EXSITING INSIDE BUILDING. RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER ISSUED FOR CONSTRUCTION 11.26.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN 389-1219 SYM REVISION En APPROVED DATE STM REVISION of APPROVED DA1E A CAFETERIA UPGRADE 12419164 SAZAN/ON 1126.13 gLATI7EZAW ® ACCEPTABILITY THIS DESIGN AND/OR SPEaF1cA110N IS APPROVED APPROVED BY DEPT. DATE DRAWN S.J.RUDELL DATE 05.15.07 CHECKED ISOMETRIC DETAILS CURRENT REVISION 12419164 SYMBOL A DAZE 11.26.13 ENGINEER -CHECKED APPROVED APPROVED nnz CAFETERIA UPGRADE BUILDING 09-94.1 11rNIJAAIIWAI II ACTED AI I SHEET M507 JOB NO. 12419164 SOMP N0. nN rrlTCO WA DWG NO. no_n0A_INan7 454 110N 5GO FOR APPROVED DATE 2 1/2 SYM 3/3/4 ONP" vo's FOR AIL RPcr 2/0 oN pEF INSTAL REVSION TO / BY p0 TO APPROVED DATE 1 TO 2 CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 3/4, /4 CN14 Vrn Fr 2 0 r Or' Orr r OP FOR AIL 52M5ON 0� DOMESTIC WATER RISER DIAGRAM ,1 i/4 1/2' SCALE: NTS ?)LArAsrAvc ® 1M110 M508 1M454 1M455 1M456 ACCEPTABILITY TH6 DESIGN AND/OR SPECIFICANON 6 APPROVED APPROVED BY DEPT. DATE DRA N ON SAZAN FOR AIL 5I1- 04 4.1/4. pET 1/21/2 3/ 3/4' VAL LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & Mtb. KITCHEN EQUIPMENT REFERENCE NO GENERAL NOTES PROVIDE ANGLE SUPPLY STOP VALVES AT ALL PLUMBING FIXTURES AND EQUIPMENT CONNECTIONS. REFERENCE DRAWINGS 109-094—UGM110 109-094-1M454 109-094-1M455 109-094—M508 109-094—M509 109-094—M510 p_5 TP4,3 UNDERGROUND PLUMBING PLANS KITCHEN AREA ENLARGED PLUMBING PLAN KITCHEN AREA ENLARGED PLUMBING PLAN HOT AND COLD WATER DIAGRAM NATURAL GAS DIAGRAM WASTE AND VENT DIAGRAM REVIEWED FOR CODE COMP UANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION 3/ 3/4' CONSTRUCTION NOTES POC NEW 3/4" CW & 3/4" HW TO EXISTING. RECEIVED CITY OF TUKWILA FEB 1 3 2014 PERMIT CENTER IS UED FOR CONSTRUCTION 11.26.13 DATE 11.20.13 SUBTIRE HOT AND COLD WATER DIAGRAM SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 • CURREM REVISION 12419164 SYMBOL Tel 206.267.1700 Fax 206.267.1701 SAZAN #206-1249 MOE 11.26.13 Tk.Ni'INELR CHECKED APPROVED APPROVED TIRE EIrrIJAAIIPAI EIACTCD CAFETERIA UPGRADE BUILDING 09-94.1 SHEET M508 JOB NO. COMP NO. nLll rEAITCD WA DWG NO. n0_nOA_1JAna LEGEND FOR LEGEND AND ABBREVIATIONS, SEE SHEETS M1a & M1b. 2" REVISION rTO 1/23 TPV- BY APPROVED DATE SIN REVISION 2 et 3 APPROVED I�$ DATE i CAFETERIA UPGRADE 12419164 SAZAN/ON 11.26.13 r' 2 2 3°, 2" SANITARY WASTE & VENT RISER DIAGRAM SCALE: NTS QBOE/NO' d 1M110 M510 1M454 1M455 1M456 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 3 2,FS pp • 2" � ^,p I,' 2 %AWN ON SAZAN LHE�xED ING1NELH IS UED FOR CONSTRUCTION 11.26.13 DATE 11.20.13 SUBTITLE 3,R KITCHEN EQUIPMENT REFERENCE NO GENERAL NOTES REFERENCE DRAWINGS 109-094—UGM110 109-094-1M454 109-094-1M455 109-094—M508 109-094—M509 109-094—M510 UNDERGROUND PLUMBING PLANS KITCHEN AREA ENLARGED PLUMBING PLAN KITCHEN AREA ENLARGED PLUMBING PLAN HOT AND COLD WATER DIAGRAM NATURAL GAS DIAGRAM WASTE AND VENT DIAGRAM REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA WASTE AND VENT DIAGRAM FEB 1 3 2014 PERMIT CENTER .. SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 • CURRENT REVISION 12419164 SYMBOL Tel 206.267.1700 Fax 206.267.1701 SAZAN 6206-1249 DATE 11.26.13 CHECKED APPROVED APPROVED IDLE CAFETERIA UPGRADE 1/CrLIAMIrAI 1IACTCD BUILDING 09-94.1 SHEET M510 JOB NO. COMP NO. Tull rrkiTCD WA DYIC Na 00-T10A-I/010