Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG14-0034 - THE NEPTUNE SOCIETY - SINK, TOILET AND BREAKROOM SINK
NEPTUNE SOCIETY 672 STRANDER BLVD PG1 4-0034 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 0005800037 Permit Number: PG14-0034 Address: 672 STRANDER BLVD Issue Date: 3/19/2014 Permit Expires On: 9/15/2014 Project Name: THE NEPTUNE SOCIETY Owner: Name: BC PARTNERS LLC Address: PO BOX 997 C/0 MK PROPERTY SVC LLC, SNOQUALMIE, WA, 98065 Contact Person: Name: CHUCK LINDBERG Phone: (425) 255-5467 Address: 12920 SE 95 WY, NEWCASTLE, WA, 98056 Contractor: Name: DIAMOND PLUMBING INC Phone: (360) 886-0440 Address: PO BOX 267 , BLACK DIAMOND, WA, 98010 License No: DIAMOPIO10JK Expiration Date: 1/4/2015 Lender: Name: Address: DESCRIPTION OF WORK: PLUMBING FOR HAND SINK, TOILET, AND BREAKROOM SINK. Valuation of Work: $6,200.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $188.38 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: IA):St Date: ���-1-( '-1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKV, 4 Community Develop , Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas iermit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: e2e9o,..51.2QO Site Address: Tenant Name: / pie' A�/4 PROPERTY ' OWNER Name: BC 4/,--i7ey, I4G Address: City5, 2 / `, e_. State: Zip: XaC,5 CONTACT PERSON — person receiving all project communication Name: (, u ck_ Address: %OZ 9c2& 5 = 7 ( GUI City: 4 BLt/; 5.7i ie___ State: wr, Zip: ffds(, Phone: (..Wass' S-9. 2 Fax: `,2$2 7/ /y5% Email: adi, "G�uG K ) t.)e&./._p 44 ,c,e, 4et Suite Number: Floor: New Tenant: © Yes ❑.. No PLUMBING CONTRACTOR INFORMATION Company Name: a40100 4/e1fr £L Address:1'0 %-0 v. (26, 2 City: , )40/ d State: , Zip: jp Phone:oD , 0 1/ 7/ Fax: 3(,i) U v v Contr Reg No.:DT9m )l Df,.1 Exp Date: /06/5 Tukwila Business LicenseNo.: Qv Valuation of Project (contractor's bid price): $ c, 02 D (1 Scope of Work (please provide detailed information):Pkiek •n4 41-ad,17 Sr f r A aod5, fX/ pp' /e, L 4 p,e,, Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/ is piping outlets being installed and the quant ;low: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent I Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Intemational Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OnE AUTHORIZGENT: Signature: l� Print Name: Mailing Address: /?6 /.367 )( ? 1,7 Day Tele hone: City Date: e,lo 2t DO/ State 9ra/v Zip H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $188.38 PG14-0034 Address: 672 STRANDER BLVD Apn: 0005800037 $188.38 PLUMBING $188.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $107.00 PLAN CHECK FEE R000.322.103.00.00 $34.88 WATER HEATER FIXTURE FEE TOTAL FEES PAID BY RECEIPT: R1411 R000.322.103.00.00 $14.00 $188.38 Date Paid: Friday, March 07, 2014 Paid By: BERT R FIELDS Pay Method: CREDIT CARD 045914 Printed: Friday, March 07, 2014 10:49 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6tu -4o / PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: - \Q l~.Iepiu"w Type of Inspection: C"1Nkit (— Add ress- _ GI sl•0f161/8'I2P Date Called: _ Special Instructions: Date Wanted: 7 ^ L / ' ` <a.m. p:m: Requester: Phone No: r'Approved per applicable codes. O Corrections required prior to approval. COMMENTS: ts-vfrub (4- t ii a l -t - REfNSP!*CTION FEE REQ. t RED. Prior to iSext inspection, fe'e must be pair `at 6 00 Southcenter 131 d.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: T PT , E� op-)v Type of Inspection: C.ky lcmA (. C's2.(<:. Addre : _ Date Called: Special Instructions: Date Wanted: 3 — 2.. 4 a:m:, "'i: p.m. Requester: CNN Phone No: ` Co75 _ (.2-764 I 5Approved per applicable codes. DCorrections required prior to approval. COMMENTS: 6 U ru NJ ti Y ,� r?�r vF_ (lnspect6r: Date: � t REINSPECTION FEE RE UIRED. Prior to next inspection, fee must be --paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORO COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0034 DATE: 03/07/2014 PROJECT NAME: THE NEPTUNE SOCIETY SITE ADDRESS: 372 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: T�J � 011,04(1 Building Division N/A -- Public Work f Fire Prevention Structural me Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 03/11/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 04/08/14 Approved with Conditions k Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: Yt REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 DIAMOND PLUMBING INC Page 1 of 2 414 Washington State Department of Labor & Industries DIAMOND PLUMBING INC Owner or tradesperson FIELDS, BERT RANDALL Principals FIELDS, BERT RANDALL FIELDS, LINDA SUSAN Doing business as DIAMOND PLUMBING INC WA UBI No. 601 921 672 P 0 BOX 267 BLACK DIAMOND, WA98010 360-886-0440 KING County Business type Corporation Governing persons BERTRFIELDS License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. DIAMOPI010JK Effective — expiration 04/12/1999 — 01/04/2015 Bond American States Insurance Co Bond account no. 32S205534 Received by L&I 05/11/2012 Insurance American States Insurance Co Policy no. 24-CC-262125-6 Received by L&I 01/29/2014 Savings No savings accounts during the previous 6 year period. $6,000.00 Effective date 04/20/2012 $1, 000, 000.00 Effective date 01/30/2014 Expiration date 01/30/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601921672&LIC=DIAMOPI010JK&SAW= 03/19/2014 PROJECT DATA: GENERAL NOTES KEY \OTES: SITE DATA: PROJECT ADDRESS: 672 STRANDER BLVD. TUKWILA, WA 98188 CURRENT ZONING: TUC (CITY OF'TUKWILA) PARCEL NUMBER: 000580-0037 PROJECT TEAM: BUILDING OWNER: BC PARTNERS,LLC CIO MK PROPERTY SERVICES SNOQUALMIE, WA, 98065 425-888-2993 TENANT: THE NEPTUNE SOCIETY ARCHITECTURAL: urban solutions studio, IIc 1555 UNION AVE NE, #66 RENTON, WA 98059 (425) 922-1474 CONTACT: GARY B. BARBER, AIA GENERAL CONTRACTOR: EDI 12920 S.E. 95th Way NEWCASTLE, WA 98056 (425) 255-5467. CONTACT: CHUCK LINDBERG WASHINGTON STATE LIC. #: CC ENRICD1128O9 WORK DESCRIPTION: INTERIOR TENANT IMPROVMENT TO EXISTING VACANT 1,878 S.F. (WORK AREA) STOREFRONT SPACE. NO EXTERIOR MODIFICATIONS TO THE BUILDING SHELL ARE PLANNED UNDER THIS SUBMITTAL. SIGN PERMIT WILL BE UNDER A SEPARATE SUBMITTAL. MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SPRINKLER WORK WILL BE UNDER A SEPARATE PERMIT SUBMITTAL. OCCUPANCY: GROUP B CONSTRUCTION TYPE: V-B SPRINKLERED (EXISTING) PARKING PROVIDED: NO CHANGE VALUATION OF WORK: $ 87,000 LEGAL DESCRIPTION MEADER HENRY D-C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84-31-SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25-23-04-BAAP ON WLY R/W LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81-07-31 W 50 FT FR C/L. THOF AT HWY ENGR STA 160+00 TH FR SD POB ALG SD WLY R/W LN S 12-18-30 E 250.45 FT TAP WCH BEARS S 81-07-31 W 35 FT FR C/L AT HWY ENGR STA 162+50 TH S 05-15-06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86-22-37 ARC LENGTH 75.38 FT TAP ON NLY RNV LN OF STRANDER BLVD TH ALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81-07-31 W 28.58 ET TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT C/A OF 19-33-22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61-34-09 W TO INTSN OF SD NLY R/W LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LNS S 87-12-48 E 194.01 FT TAP ON WLY R/W LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08-52-29 E 165.06 FT TO POB ENERGY CODE NOTES NO BUILDING ENVELOPE MODIFICATIONS TO CONDITIONED SPACES ARE PROPOSED. ANY WORK SHALL MEET OR EXCEED ANY PERTINENT CITY OF SEATTLE ENERGY CODE REQUIREMENTS. 1. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S. SAFETY MEASURES. 2. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 3. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS. THE APPROVED] PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. 4. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS OTHERWISE NOTED. 5. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 6. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CANNOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 7. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE INTERNATIONAL BUILDING CODE, NATIONAL ELECTRICAL CODE AND ALL OTHER APPLICABLE STATE OR LOCAL LAWS AND • REGULATIONS. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED AS TO PERMIT WORK WHICH IS NOT CONFORMING TO THE PREVIOUS LISTED CODES. 8. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICES. 9. LIGHT AND VENTILATION SHALL COMPLY WITH I.B.C.; SECTION 1203, 1204 & 1205. 10. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND AFFECTED BY NEW CONSTRUCTION. 11. MECHACNICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION SUBCONTRACTORS WILL BE RESPONSIBLE TO SUBMIT SEPARATELY FOR PERMITS FOR THEIR RESPECTIVE WORK SCOPES FOR THIS PROJECT. 12. ILLUMINATED EXIT SIGNS TO BE LOCATED PER CITY OF TUKWILA FIRE MARSHAL REQUIREMENTS. 13. ALL NEW INTERIOR FRAMED WALLS TO BE BUILT TO UNDERSIDE OF EXISTING T-BAR CEILING - GC TO BRACE TOP OF WALL TO STRUCTURE ABOVE AS REQUIRED PER CODE. 14. ALL INTERIOR DOOR HARDWARE TO BE LEVER -TYPE. SEPARATE PERMIT REQUIRED FOR: 46 Mechanical .KEiectrical 0 Plumbing Gas Piping City of Tukwila BUILDING DIVISION PROX. AREA OF WORK FELE COPY Permit No.� Plan review approval is subject to errors and omissions. 4p Droval of construction documents does not aut rr z9 the o anon of any adopted code or ordinance. R xelp t flf approved Field a..y and .• s is acknowledged. By /!� ►- - �� Date: III City Of Tukwila BUILDING DIVISION EMPL. TOILET FAMIL REVIEWED FOR CODE C LtcfCE APPROVED MAR 1 20114 City Of BUILDING C=NTER iia ISION REVISIONS No changes shall be made to the scope of work without prior approve, of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REFLECTED CEILING PLA 3/16 = 1'-0" FLOOR 3/16 = 1'-0" -j511/15" (E) PLAN 23'-4 1 /2" CLR (E) RECEPTION / WAITING EMPL TOILET 8' 0') (E) FAMILY ROOM #1 FAMILY ROOM #2 SALES MANAGER IT/ METER / STORAGE -11 1 /2 7'-11 5/16" (E) • (E) 1. EXISTING TENANT DEMISING WALL TO REMAIN AS SHOWN EXISTING STOREFRONT SYSTEM TO REMAIN - NO CHANGES EXISTING ACCESSIBLE TOILET ROOM, FINISHES AND L FIXTURES TO REMAIN - NO CHANGES: EXISTING ELECTRICAL PANEL LOCATION TO REMAIN UNCHANGED. ELECTRICAL SUBCONTRACTOR TO SUBMIT SEPARATELY FOR ELECTRICAL PERMIT FOR WORK ON THIS PROJECT. ELECTRICAL OUTLETS ARE SHOWN FOR SPACE PLANNING REFERENCE ONLY (TYPICAL). ELECTRICAL SUBCONTRACTOR TO SUBMIT. SEPARATELY FOR ELECTRICAL PERMIT FOR WORK ON THIS PROJECT. 6. DATA OUTLETS ARE SHOWN FOR SPACE PLANNING REFERENCE ONLY (TYPICAL). TENANT TO COORDINATE LOCATION WITH ELECTRICAL SUBCONTRACTOR. 7. ALL FLOOR AREAS SHOW TO RECEIVE CARPETING UNLESS NOTED OR SHOWN OTHERWISE.. 8. 8'-0" WIDE X 6'-0" DEEP AREA (CTR ..ON DOORS) W/ 12' X 12" CERAMIC TILE (DALTILE HEATHLAND COLOR: ASHLAND) TYPICAL INTERIOR FRAMED PARTITION: 3-%" 35. GA. METAL STUD Q 24 O.C. W/ 5/8" GWB EACH SIDE; 3 Y2" SOUND BATT INSULATION ® OFFICE AND RESTROOM: WALLS (TYPICAL UNLESS NOTED OR SHOWN . OTHERWISE) • 10. TYPICAL INTERIOR DOOR: 3'-0 X .7'-0" X 1 %" SOLID CORE, PAINT GRADE (COLOR : TO: MATCH ADJACENT WALL PAINT) IN 18GA HM FRAMES 11.: OVERHEAD CABINETS WITH MICROWAVE OVEN SHELF 12.:. SS BAR > SINK. PLUMBING SUBCONTRACTOR: TO SUBMIT SEPARATELY FOR PLUMBING PERMIT FOR WORK: ON THIS PROJECT 13. 36" ` TALL' BASE CABINETS 14. REFRIGERATOR (BY TENANT) 15. EXISTING SUSPENDED ACOUSTIC CEILING TO REMAIN GC TO REMOVE TILES, PAINT AND REPAIR GRID AS REQUIRED AND INSTALL NEW 2'X4' TILES (ARMSTRONG DUNE 1777, COLOR WHITE) 16. RELOCATE EXISTING 2'X4' FLUOR. TROFFER FIXTURES AS SHOWN - RELAMP AS REQUIRED. TO INCLUDE (3) 32W T8 LAMPS EACH FIXTURE 17. EQUIPMENT/FIXTURE BY TENANT 18. 42" WIDE X 78" HIGH RELITE IN PAINTED WOOD FRAMES - Y" CLEAR TEMPERED GLASS; ALIGN TOP EDGE OF. RELITE WITH TOP EDGE OF ADJACENT DOOR.. TYP. AS SHOWN. 1.9. 24" D S • RTOP MO ORT WITH SINGLE CENTERE ` 1/ i lZ br4vi,. 44 mat rAmnok. 0 t/n 0 0 cn - z 8 0 Fr) 0 cc 3 AT 36" A.F.F; VID CEiViD TY OF TUKWILP. ,• 07 2014 MT CENTER U z DATE REMARKS B1' - 03/03/14 PERMIT SUBMITTAL , ,. I PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING 1 1 1 1 T T 4 T , 1 • DRAWN BY: GBB CHECKED BY: GBB JOB #: 14-01047 DATE: 03/03/14 SHEET #: L A1J