PLUMBING/GAS PIPING PERMIT
0002800009
13925 INTERURBAN AVE S
Project Name: EVERGREEN BUSINESS CAPITAL
Permit Number: PG14-0038
Issue Date: 3/25/2014
Permit Expires On: 9/21/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
EVERGREEN BUSINESS CAPITAL
13925 INTERURBAN AVE S #100 ,
SEATTLE, WA, 98168
DARYL RODGERS
175 ROY RD SW , PACIFIC, WA, 98047
RESCUE ROOTER
965 RIDGE LAKE BLVD SUITE 201,
MEMPHIS, TN, 38120
RESCUR*007Q7
/1/
Phone: (253) 468-2683
Phone: (253) 872-4902
Expiration Date: 1/1/2016
DESCRIPTION OF WORK:
REPAIR UNDER SLAB WASTE LINES IN 2 PLACES BY INSTALLING A LINER WITHIN THE PIPE
Valuation of Work: $17,000.00
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Fees Collected: $163.16
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Permit Center Authorized Signature:
(,),A W
Date:
'6— H 1 Lt
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development nd agree to the conditions attached to this permit.
Signatur
Print Name:
Date/�
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: When special inspection is required, either the owner or the registered design professional in responsible
charge, shall employ a special inspection agency and notify the Building Official of the appointment prior
to the first building inspection. The special inspector shall furnish inspection reports to the Building
Official in a timely manner.
2: A final report documenting required special inspections and correction of any discrepancies noted in the
inspections shall be submitted to the Building Official. The final inspection report shall be prepared by
the approved special inspection agency and shall be submitted to the Building Official prior to and as a
condition of final inspection approval.
3: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
4: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
5: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
6: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
7: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
8: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving
notification that the work is ready for inspection.
9: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
10: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
11: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
12: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be
protected in accordance with the requirements of the building code.
13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any
other ordinance of the jurisdiction.
15: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this
permit.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
9001 UNDERGROUND
CITY OF TUKW- 1
Community Developmt... Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Ga.., /ermit No. 1 GH-
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: /_3
r King Co Assessor's Tax No.:
z .hTee(A.ravc._
WO2- o-- owl
Suite Number: Floor:
Tenant Name: ----yre Qom/h,Si Cho trbz / New Tenant: ❑ Yes ❑.. No
PROPERTY OWNER
//jj
Name: veP� i"CPih gt1S i y�SS
/
L Op/tOl I
Addr-esss:��12, / t�f Grt�"J' ,
t-
L' �j-
State: , /a' .
City: / q k 1./ 11l a
Q
Zip: l o �U
CONTACT PERSON — person receiving all project
communication
Name: �/
94� 1 /o�9 P ✓s
Address: v
City: State:
Zip:
Phone 3_ U� ? _2 G n Fax:
l
Email:
PLUMBING CONTRACTOR INFORMATION
Company Name:
eS t it e koyJ fc1
Address: / 7S cot , f
City: 4 ; `� State: �Q,
Zip: d?o
c � �%� y Y7
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
Valuation of Project (contractor's bid price): $ / 7 00D < 00
Scope of Work (please provide detailed information): ]f 1,s741 (( q (, ei-
Building Use (per Int'l Building Code):
Occupancy (per Int'1 Building Code):
Utility Purveyor: Water: Sewer:
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/ is piping outlets being installed and the quaff )elow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
^
drainage or vent piping
L
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER.
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OR AUT OR + D GENT:
Signature: /mot
/17(
Print Name: G!Y'�J ( R&t,c Da
Telephone: ✓ 33 Y (� akd Y3
Mailing Address: / 7 iC, /4, SE;L/. tt/r9 ( 61
/Gt �0
City State Zip
Date:
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY
PAID
$135.28
PG14-0038
Address: 13925 INTERURBAN AVE!S
Apn: 0002800009
$135.28
PLUMBING
$129.00
PLAN CHECK FEE
R000.322.103.00.00
$3.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$93.00
TECHNOLOGY FEE
$6.28
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R1585
R000.322.900.04.00
$6.28
$135.28
Date Paid: Tuesday, March 25, 2014
Paid By: RESCUE ROOTER
Pay Method: CHECK 007538
Printed: Tuesday, March 25, 2014 9:27 AM 1 of 1
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT
QUANTITY
PAID
PermitTRAK
$27.88
PG14-0038 Address: 13925 INTERURBAN AVE S
Apn: 0002800009
$27.88
PLUMBING
$27.88
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R1458
R000.322.103.00.00
$27.88
$27.88
Date Paid: Thursday, March 13, 2014
Paid By: AMERICAN RESIDENTIAL SERVICES
Pay Method: CHECK 6007529
Printed: Thursday, March 13, 2014 12:14 PM 1 of 1
CR
SYSTEMS
4(
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451
?G1 _od32
Project:
j, U61GeAJ & i s CA?,`714,�j
Type of Inspection:
'& U 6 tf . 1 kiAi4.
Address-
Date. Called: r 'Ai
Special Instructions: _r—
Date Wanted:
-4 — (-4 `(4
,a.m,
A.m.
U^0 S (4& wits( e-
Requester:
Phone No:
Approved per applicable codes.
sl-pri�a jQ ppr aI.
COMMENTS:
(;)
t
t IQ
`L-1— K)3dK5
I
Inspector:
rM Leo .p(P (-)
li
Date4
[4
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection.
5Pe (a- Zfrt7 Pe ti)r' r".
p Qi4ew epf
1;4 /0.ee-474 ogeeq
-t-• ivippicf-/4/r J') .A011( ri-d.u.'41470/-4
0ef
SEPARATE POW IT
REQUIRED FOR:
gioMethanical
goelectrical
O Plumbing
giotas Piping
} of Tukwila
"JG DIVISION
FXEL.:•OPY
Perrin O. volA
Pt tW approval is subject to enors and otissfrrIl
t,' • 01 con4nclion documents does not auTh':-.)
Idopted code or ordnance.
LiJpi voted Copyaid,qwflsknOWIedgGi
BY
paw
Tukwila
G DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: revisions will require a new plan submittal
and may include additional plan review fees.
I% li1OE39
t
Sew/ e_vcf co nc,reia c4f af
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 0 2014
frT Are-
Cky of Tukwila
BUILDING DIVISION
4
CA.4.1;1 COI ckdeli (Al
fi ;/°tITY 0SETIVEWILA
M 1 3 2014
P RMIT CENTER
d CAA. /1 cd,5
FiEu,I&Q'
�n�.
set of construction documents S'
i-^pi at the S1te of work and shalt ha
, inspection by the Bulking Official
tt duly authorized presentative.
City Of 1'takwiia
Rt l ILDING DIVISION
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
ectrical
❑ Plumbing
ias Piping
' `'v of Tukwila
Bk.,‘ `; „ DIVISION
SrA+AA---- ii\yeaci avk
Oe •y$ri o ry e(/✓' 6--
\Ks ecAion ctre1/4C1 c•evA-i eok *-o b �t
A S i' % +ems 4h� S g•f6A-evv
e 0,r11-5 ti` \.c. prd t
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
7
/ia/4i
MI/14 !n
/r.
SCC.c.✓ e-N1— L0hLPe-�E./ tat
0 4
REVIEWED FOR
OE COMPLIANCE
• APPROVED
F: MAR 2 0 2014
A:7-
City of Tukwila
$UILO1NG DIVISION
o E� 4i" fi'/'e- RECE,IED
CITY O< UKWILA
AR 1 3 2014
PERMIT CENTER
„fi r 1 71 C
u 5ta;'s ifatICej
on 1L0 of Ad m -
Sla j✓s /,,?th roo4S
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 0 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAR 1 3 2014
PERMIT CENTER
Fran COPY
ofhtfri der /3 e,
o i ,
cajJ
e-
u_ ctiik
I ttC a icily ta, fr -6o
1_112_ a4t
(Pilo
ne L5In /Sfe
64 / rte- r- e- ikeK6
CL LcAtl_ej yiV&v
Lich, /ass-
tt:LL f-c) c
_
Lef/P-L_____sm
ex
t.
11
R-EXIMWED-FOR
__COD C.E.APPROVEDMtkki 0 2014
City oTulavila—
suiLoiNp DIVISION
RECEIVED
CITY OF TUKWILA
MAR 1 3 2014
PERMIT CENTER
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology
Page 1 of 7
PERMA-LATE
EXPERIENCE THE PERMA
i2ag(
2.-(_./CF- 2_6 213
RAL LINING SYSTEM
LINER TM DIFFERENCE
PERMA-LINERTMPRODUCTS & SYSTEMS» PERMA-LATERAL PIPE LINING SYSTEM
EQUIPMENT
THIS IS THE NEXT
Experience The Peri a-L
0
MATERIALS
TRAINING
LEVEL OF PIPELINE REHABILITATION
ierTM Difference
FIELD COPY
U.S. TOLL FREE: 1-8 -33 - 5 8
INTERNATIONAL: 1-1 1:501.9149
LIVE HELP IS OFFLINE. MESSAGf
SEE
VIDEOS
PMG
NEWS & EVENTS
OUR COMPANY
KILSAV :<
Now you can service pipelines in diameters
from 2" to 8" in less then a day and in most
cases less then 3 hours! This "true" inversion
method allows the Perma-LateralTM lining
materials to negotiate 22's, 45's and sweeping
90's with ease. Our liner material allows our
installers to line through 4" - 6" transitions
without changing the structural properties of
the liner.
Only Perma-LateralTM liner materials have a
reinforced scrim to eliminate stretch during the
inversion process. The reinforcement scrim
(patent pending) allows the I ner to invert smoothly through the existing pipeline whti&oWventina the IinPt f nr. .-ItPt<, • ^. Our installers are
able to line an existing pipeli le without inverting into city sewer mains.
Peri a-LinerTM F
Continuous Inversion
Continuous inversion fo • 3" to " dial"*eter pipes
• Continuous inversion 'or 3" to 6" diameter pipes "patent pending"
• Built-in patented camera inspection port
• Steam or hot water ce n be used "Patent Pending"
• 150 + Feet in one cortinuous install
• Perma-LinerTM F-6 Continuous Inversion
• New 3/4" Manifold Sy>tem designed specifically for the f-6
• lubricant pressurized >elf -contained tank and auto feed oiler
• portable and user-frie idly
• Designed to work with PLI scrim reinforced materials "patent pending"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 0 2014
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAR 1 3 2014
PERMIT CENTER
The Perma-LateralTM Lining System / Cured -In -Place Pipe (CIPP) is approved for lining existing
2" to 8" diameter pipelines in the City of Los Angeles, Ca. The approval has been granted by the
City of Los Angeles, Ca. Department of Building and Safety per strict Los Angeles Plumbing
Code (LAPC) requirements and 3rd party testing. Perma-LateralTM ng Materials meet their
http://www.perma-liner. com/perma-lateral-nipelining-system. html
2/27/2014
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology Page 2 of 7
I strict non -stretch liner requirements. Only Perma-LinerTM' provides non -stretch lining materials.
sa The Perma-LateralTM' liner allows the installer to invert the liner through the existing building
sewer pipeline to the city main sewer connection without stretching into the city sewer main.
Normal felt liners can stretch into the city sewer main and cause blockages that require
emergency digging and/or robotic cutting devices.
The Perma-LateralTM' liner and calibration tube is manufactured in 330' length rolls. Our logistics department handles your order and delivers
the products to meet your schedule. Our Perma-LateralTM' transition liner is manufactured to your job specification. The Perma-LateralTM'
transition liner is manufactured to your exact length.
GET
STARTED
TODAY!
CLICK HERE
The Perma-LateralTu ambient cure resin is formulated to meet the installer's needs. Perma-LinerTM' has formulated its resin for all working
temperatures. The Perma-LateralTM' epoxy resin will provide you plenty of working time with a 3 hour cure time. The epoxy is pre -formulated
and shipped to you in 5 gallon containers. The formulation is a 2-part mix. You simply measure the quantity of resin needed and introduce it
into the liner. There's no waste of materials. This system is user friendly!
PERMA-LATERAL ADVANTAGES PERMA-LATERAL SPECIFICATIONS
Features & Benefits of our Pei(a-Lateral Lining SysteM Consistant Installations!
• Formulated Epoxy Resins
• Re -Line 22's, 45's & Sweeping 90's
• NSF Standard 14 Approved
• Eliminate Root Intrusion
• Bridge Missing Pipe Sections
• Increase Flow Efficiency
• Minimum Design Life 50 Years (Tested)
• Non -Woven / No Stretch Liner
• Single Point of Access for Lining
• Seal Open Joints
• Prevent Pipe Failure
• Reline 4" to 6" Transitions
• Stop Infiltration / Ex -Filtration
• IAPMO Certified
Perma-LinerTM' Industries, Inc. has spent years of research and
development in order to fumish you quality materials and proven
installation methods. Both municipal government agencies and
private owners of building sewer laterals expect this quality in
every project. To ensure this quality is consistent in every
application, Perma-LinerT"' has installation and material
specifications for our Perma-LateralTM' Certified Installers to follow.
The specifications are used by municipal government agencies
throughout the world for contracting services.
Our Perma-LateralT"' 3rd party testing exceeds the industries
standards as per ASTM F1216. The installation practices set forth
in our specifications will guarantee your company or agency
consistent results... every time!
Please contact us for an up-to-date list of Perma-Laterarm
Certified Installers in your area.
Download Lateral Lining Specifications PDF Here
PERMA-LATERAL VIDEO DEMONSTRATIONS
IN -GROUND PERMA-LATERAL LINING SYSTEM
http://www.perma-liner.com/perma-lateral-pipelining-system.html
2/27/2014
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology
Page 3 of 7
x IN -GROUND PERMA-LATERAL LINING SYSTEM
In -Ground Perma-Lateral Lining
System Demo
Video 1 of a 3 part series.
Courtesy of YouTube
In -Ground Perma-Lateral Lining
System Demo
Video 2 of a 3 part series.
Courtesy of YouTube
SECTIONAL POINT REPAIR VIDEOS (BEFORE & AFTER)
•I 101°
Ng E.E..IP TAt.ENEF {. �
._ x.__ r r .f
Sectional Point Repair Demonstration
Before Point Repair Lining
Video 1 of a 2 part series.
Courtesy of YouTube
PCINT PEPRIR TAVENEP DP
Sectional Point Repair Demonstration
After Point Repair Lining
Video 2 of a 2 part series.
Courtesy of YouTube
TEAR AWAY, INNER -SEAL & LATERAL LINING DEMONSTRATION VIDEOS
!
Tear Away Demonstration
Perma-LinerT" Industries
Video 1 of a 1 part series.
Courtesy of YouTube
VIDEO COMING VERY SOON
InnerSeal Connection Demonstration
Perma-LinerTM Industries
Video 1 of a 1 part series.
Courtesy of YouTube
In -Ground Perma-Lateral Lining
System Demo
Video 3 of a 3 part series.
Courtesy of YouTube
Lateral Lining Demonstration
Perma-LinerTM Industries
Video 1 of a 1 part series.
Courtesy of YouTube
3rd Party Testing Download Docu(hentation
Download any of our 3rd Party Testing Docuilents Below: - Updated 11-7-2012
The Perma-Lateral 3rd party testing documents are available for download. These are .PDF files that can easily be saved to
your computer for future use. Your web browser will open these files as a friendly web page. For any questions concerning
our documentation, please contact us. We will be happy to assist you.
J
*2012 NSF Certificate *Lateral Lining ASTM D790 D638 D695 Testing
',CRT Flow results April 2009 *NSF Test Results
•IAPMO 2013 Certificate
2013 Perma-LinerT" Industries LLC.
13000 Automobile Boulevard, Suite 300
Clearwater, Florida 33762
U.S. Toll Free: 1-866-336-2568
International: 1-727-507-9749
Rater F.mironment
Federation'
NSF.
•STT
(APIA
Designed, Optimized, Powered By: Archi FX LLC. Web Design Tampa
All conten on this website is the sole property of Perma-Liner^^ Industries and shall of be duplicated.
All logos on this website are the property of their respected owners.
ARCHII*
ts3
Home I Products I Perma-University I News & Events I Our Company I Become an Installer I Contact Us
http://www. perma-liner. com/perma-lateral-pipelining-system.html
2/27/2014
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology Page 4 of 7
Follow Us Social Media:
CI CO el
http://www.perma-liner.com/perma-lateral-pipelining-system.html 2/27/2014
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology Page 5 of 7
http://www.perma-liner.com/perma-lateral-pipelining-system.html 2/27/2014
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology Page 6 of 7
http://www.perma-liner.com/perma-lateral-pipelining-system.html 2/27/2014
Perma-Lateral Pipe Lining System I Trenchless Pipelining Technology Page 7 of 7
http://www.perma-liner.com/perma-lateral-pipelining-system.html 2/27/2014
AD
0
Ss;
104
ii•
NSF International
RECOGNIZES
4=>
W
> Cr"
0 wo.
0
Perma-Liner Industries, Inc.
Facility: Clearwater, FL
AS COMPLYING WITH NSF/ANSI 14 AND ALL APPLICABLE REQUIREMENTS.
PRODUCTS APPEARING IN THE NSF OFFICIAL LISTING ARE
AUTHORIZED TO BEAR THE NSF MARK.
Cc:: icIii,n Pn :
:•• by
At.. ric,11,,z7 .
CL-rtirl.:ation Pro: . .1
Aeditea h the
St tr C.:nu ncil
of Canad:,
PERMIT CENTER
This certificate is ihe property of NSF International and mu,t be returned upon request. For the most current and complete information, pleae. aeces.s NSF's ‘vehhite(www.m.f.orn).
October 12, 2012
Certificate# 0D471 - 03
David Purkiss, General Manager.Water Systems
Water Distribution Systems
Aug. 15. 2(112 9:49AM
HIM, Pape Onneultan[e, Inc.
420 Ptekering Street, Houston, TX 77091
w ww,htspipo oo nsuita n tlwo re
August 14, 2012
Phone 713.692.8379
Fax 713-882.13502
boll Free 1-800.892•ThST
No. 0011 P. 2/ 2
Pipe Consultants
IITS port #:
Mr. Steve Parks
Perma-Liner Industries
13000 Automobile Boulevard, Suite 300
Clearwater, FL 33762
PLIF219,005.doc
Customer Project Name:
P.O.
Date Sample Received:
Date Sample Tested:
9751
8/06/12
8/14/12
One (1) sample of cured -in -place pipe liner was delivered to HTS' laboratory for testing. The sample was tested in
accordance with ASTM D695, ASTM D638 Type 1I, and ASTM D790 Method 1 Procedure A. A Support Span -to -Depth
Ratio of 16 to 1 was used as specified in the test standard ASTM D790. Thickness measurements, compressive strength,
tensile strength, tensile modulus, flexural stress and flexural modulus of elasticity tests were performed on the sample.
Five (5) specimens were cut and tested from the sample- The results summarized and reported below are averages of the
five (5) specimens. A test report for the sample is attached.
SAMPLE
ID
COMPRESSIVE
STRENGTH
(psi)
ASTM D 695
TENSILE
STRENGTH
(Psi)
ASTM D 638
TENSILE
ELONGATION
(%)
ASTM D 638
FLEXURAL
STRENGTH
( psi)
ASTM D /90
FLEXURAL
MODULUS
( psi)
ASTM D 790
Lateral Lining
4126
5926
6-5
12,198
408,382
The following table contains the thickness measurements for each individual specimen tested,
MEASUREMENT OF THICKNESS FOR PIPE
ASTM D 2122
_
Camtlined
Average/Specimen
in
Total
tont
Sample
iii
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
No. 7
No.8
Lateral Lining
.160
.157
.154
.166
.153
.158
.151
.167
0.158
4.0
Sincerely,
Rick Eastwood a
Vice President
Technician
E. Carrillo
Time
2h s
This test report relates only to the items tested and shall not be reproduced except in full without approval of HTS, Inc.
1'LWF219,005,doc--Page 1 of 1
Serving the Pine Rehabilitation Industry
NSF International
789 N. Dixboro Rd. Ann Arbor, MI 48105, USA
1-800.NSF.MARK l +1-734.769.8010 l www.nsf.org
TM
Live Safer
Send To: 0D470
Mr. Gerald D'Hulster
Perma-Liner Industries, Inc.
13000 Automobile Boulevard
Suite 300
Clearwater, FL 33762
TEST REPORT
Facility: 0D471
Perma-Liner Industries, Inc.
13000 Automobile Boulevard
Suite 300
Clearwater, FL 33762
Result
PASS
Report Date 20-JAN-2012
Customer Name
Tested To
Description
Trade Designation
Test Type
Job Number
Project Number
Project Manager
Perma-Liner Industries, Inc.
ASTM F1216-2011 - NSF/ANSI 14
PERMA-LINER 5" long green pipe with liner
PERMA-LINER
Annual Collection
A-00100661
9098138 (PL01)
Sarah Meagrow
Thank you for having your product tested by NSF International.
Please contact your Project Manager if you have any questions or concerns pertaining to this report.
Report Authorization
Date 20-JAN-2012
Ata Ciechanowski - Asst. Director, Engineering Laboratory
FI20120120135259 A-00100661
Page 1 of 6
This report shall not be reproduced, except in its entirety, without the written approval of NSF. This report does not represent NSF Certification or authorization to
use the NSF Mark. Authorization to use the NSF Mark is limited to products appearing in the Company's Official NSF Listing (www.nsf.org). The results relate only
to those items tested, in the condition received at the laboratory.
Summary of Test Results
Family Code
Physical Description of Sample
Print Strip
Test Description
Trade Designation/Model Number
01
5" long green pipe with liner
Diamond pvc pipe 4" 100mm pvc 12454 type psm sdr 35
sewer/egout astm d3034 b182.2 14f max h32 b c0f1c5 18:33
ANNUAL PERFORMANCE TESTING
PERMA-LINER
Test Description
Result
Flex Modulus Test
Pass
Flexural Strength Test
Pass
Gravity Pipe Leakage Test:
Pass
Tensile Strength Test
Pass
FI20120120135259
A-00100661
Page 2 of 6
This report shall not be reproduced, except in its entirety, without the written approval of NSF. This report does not represent NSF Certification or authorization to
use the NSF Mark. Authorization to use the NSF Mark is limited to products appearing in the Company's Official NSF Listing (www.nsf.org). The results relate only
to those items tested, in the condition received at the laboratory.
P3O84 - Gravity Pipe Leakage Test
Sample Description 001023
Initial water column: 2 feet
Final water column: 2 feet
Time: 60 minutes
Allowable Leakage 38.4 mL
Actual Leakage 0 mL
Test Duration 60 minutes
Leakage rate: 0 g/in/day
Required maximum leakage rate: 50 g/in/day
Actual leakage rate: 0 g/in/day
Gravity Pipe Leakage Test: Pass
P3122 - Flex Modulus
Specimens conditioned for
Specimens conditioned at
Relative humidity
Test temperature Required
Test temperature Actual
Required crosshead speed
Actual crosshead speed
Actual Average Modulus
Flex Modulus Test
>40 hours
73 degrees F
50
73 degrees F
73 degrees F
0.08 in/min
0.08 in/min
362000 psi
Pass
Test Results
Flex Modulus
(psi)
Required
250000
Specimen 1
347000
Specimen 2
378000
Specimen 3
373000
Specimen 4
333000
Specimen 5
377000
F120120120135259
A-00100661 Page 3 of 6
This report shall not be reproduced, except in its entirety, without the written approval of NSF. This report does not represent NSF Certification or authorization to
use the NSF Mark. Authorization to use the NSF Mark is limited to products appearing in the Company's Official NSF Listing (www.nsf.org). The results relate only
to those items tested, in the condition received at the laboratory.
P3123 - Flexural Strength Test
Specimens conditioned for
Specimens conditioned at
Relative Humidity
Required Test Temperature
Actual Test Temperature
Required Cross Head Speed
Actual Cross Head Speed
Average Flexural Strength
Flexural Strength Test
>40 hours
73 degrees F
50 percent
73 degrees F
73 degrees F
0.08 in/min.
0.08 in/min.
9650 psi
Pass
Test Results
Flexural Strength
(psi)
Required
4500
Specimen 1
9260
Specimen 2
9290
Specimen 3
9450
Specimen 4
9940
Specimen 5
10300
P3127 - Strength, Tensile
Specimens conditioned for
Specimens conditioned at
Relative humidity
Required Test Temperature
Actual Test Temperature
Actual Crosshead Speed
Required Crosshead Speed
Actual Average Tensile Strength
Standard Deviation
Tensile Strength Test
>40 hours
73 degrees F
50
73 degrees F
73 degrees F
0.2 in/min.
0.2 in/min.
5410 psi
370 psi
Pass
Test Results
Tensile Strength
(psi)
Required
3000
Specimen 1
5680
Specimen 2
5590
Specimen 3
5050
Specimen 4
5780
Specimen 5
4970
P3172 - Specimen Fabrication
Specimen Fabrication
Time
COMPLETE
1.5
hours
F120120120135259
A-00100661
Page 4of6
This report shall not be reproduced, except in its entirety, without the written approval of NSF. This report does not represent NSF Certification or authorization to
use the NSF Mark. Authorization to use the NSF Mark is limited to products appearing in the Company's Official NSF Listing (www.nsf.org). The results relate only
to those items tested, in the condition received at the laboratory.
F120120120135259
A-00100661
Page 5 of 6
This report shall not be reproduced, except in its entirety, without the written approval of NSF. This report does not represent NSF Certification or authorization to
use the NSF Mark. Authorization to use the NSF Mark is limited to products appearing in the Company's Official NSF Listing (www.nsf.org). The results relate only
to those items tested, in the condition received at the laboratory.
Testing Laboratories:
All work performed at.
Flag
(Unless otherwise specified)
Id Address
► NSF_AA
References to Testing Procedures:
NSF Reference Parameter / Test Description
NSF International
789 N. Dixboro Road
Ann Arbor MI 48105
P3084 Gravity Pipe Leakage Test
P3122 Flex Modulus
P3123 Flexural Strength Test
P3127 Strength, Tensile
P3172 Specimen Fabrication
Test descriptions preceded by an asterisk "*" indicate that testing has been performed per NSF International requirements but is
not within its scope of accreditation.
FI20120120135259 A-00100661
Page 6 of 6
This report shall not be reproduced, except in its entirety, without the written approval of NSF. This report does not represent NSF Certification or authorization to
use the NSF Mark. Authorization to use the NSF Mark is limited to products appearing in the Company's Official NSF Listing (www.nsf.org). The results relate only
to those items tested, in the condition received at the laboratory.
IAPMO RESEARCH AND TESTING, INC.
5001 East Philadelphia Street, Ontario, California 91761-2816 • (909) 472-4100 Fax (909) 472-4244 • www.iapmo.org
ANSI Accredited Program
PRODUCT CERTIFICATION
%APM
R&r
TM
Standards Council of Caads
,andm r.a•dmdm,
Canil ow. dmnomw
o,paaa mnx,nen*MI
CERTIFICATE OF LISTING
IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a
combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the
supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in
the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product
acceptance by Authorities Having Jurisdiction.
Effective Date:
Product:
Issued To:
IDENTIFICATION:
April 2012
Cured -In -Place Thermosetting Resin Conduit
Liner
Perma-liner Industries Inc.
13000 Automobile Blvd #300
Clearwater, FL 33762
Void After: April 2013
File No. C-4397
Manufacturer's name or trademark, model description of woven or nonwoven
material and associated thermosetting resin, and the C/IAPMO° triangular
certification mark.
CHARACTERISTICS: Materials for the reconstruction of pipeline and conduits (4" to 108")
by the installation of a resin impregnated flexible tube which is
inserted into the existing conduit by use of a hydrostatic head of air
pressure. To be installed in accordance with the requirements of the
manufacturer's installation instructions.
MODELS:
Manufactured in compliance with ASTM F 1216-2009.
Products listed on this certificate have been tested by an IAPMO R&T
recognized laboratory. This recognition has been granted based upon the
laboratory's compliance to the applicable requirements of ISO/IEC
17025.
Chairman, Product Certification Coifjnittee
uM (241-4,4-7
CEO, The IAPMO Group
For the most accurate and updated information please visit http://pld.iapmo.org/C-4397
This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material,
manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of
non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing.
Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc.
Any alteration of this certificate could be grounds for revocation of the listing.
Product:
Issued To:
#PL
!AMC) RESEARCH AND TESTING, INC.
CERTIFICATE OF LISTING
Page 2
Cured -In -Place Thermosetting Resin Conduit
Liner
Perma-liner Industries Inc.
Void After: April 2013
File No. C-4397
ISO 9001:2000
CRT
/�j INC
LABORATORTES, lL'F/(lama
1680 North Main Street, Orange, CA 92867
(800) 597-LABS (5227) • (714) 283-2032 • Fax (714) 283-1365
www.crtlabs.com - e-mail: crtlabs6ricrt1abs.corn
ASTM Physical &Mechanical • Chemical-Thenna.l Analysis • IAPIv10 Cell Class
Geosynthetic Materials • Plumbing & .Faucet Assemblies • Resin & Finished Product Testing
TEST REPORT
PAGE
1
of 4
FOR. Perma-Liner Industries, Inc.
13000 Automobile Blvd. Suite-300
Clearwater, FL 33762
Tel: (727) 235-1385 / Fax: (727) 507-9849
ATTN: Mr. Michael L. Finocchio
I..WR NO.: 18010-R1 nATI::: April 21 2009
BACKGROUND: Customer submitted two (2) samples of 4" PVC (SDR) pipe for flow rate /
calculations and comparison analysis. The samples arrived on 03/20/2009 via
customer supplied courier. Visual inspection was performed on 03/23/2009 and
no product defects were noted. Samples submitted to compare theoretical values
of friction loss for PVC unlined sewer pipe versus lined PVC-FRP pipe. Testing
in accordance with customer P.O. # 15357 received on 03/18/2009 and signed
CRT quotation dated 03/19/2009.
REVISIONS: Additions to this report include data from CRT LWR-16149 (02/14/2005)
CRT order entry log date: 03/20/2009 / Report due date: 04/01/2009
PROCEDURES:
TEST SUMMARY:
COMMENTARY:
RESULTS:
Sample description: 1) Charlotte Pipe 4" PVC Sewer pipe (un-lined)
2) Charlotte Pipe 4" PVC- FRP Sewer pipe (lined)
Flow (q) — Manning formula and Williams -Hazen formula
Coefficients of flow — PPI Technical Reports
Maximum flow rate (gpm) — CRT / ANSI methods
Flow Rate Calculation (gpm) — CRT method
According to CRT's calculations (and related formulated calculations) PVC
sewer pipe product flows better than PVC-FRP sewer pipe with a joint every
10-feet due to the smoothness of the interior and the lack of turbulence..
Friction loss was minimized, which signifies that the lining system is very
efficient. However, respective municipalities have the ultimate decision of
acceptance.
Test results are shown in the attached data table(s), attached.
Specimen Retain Bin: R & D (30 day hold only unless otherwise specified)
CRT LABORATORIES, INC.
UL Certified -Registered ISO 9001.: 2000 / ISO 17025: 2005 Compliant
Ken A. Le Jeune
C.O.O. Laboratory Director
Raul Gonzalez Jeff Blackford
Laboratory Technician Senior Laboratory Manager
The liability of CRT Labs with respect to the work and report covered herein. shall in no event cscced the amount of the invoice. we recommend consideration that correlative data be generated by other
laboratories in masers of litigation. CRT will retain tested samples for 3n days after testing is cotnpleted, unless other arrangements are agreed upon at the time order is placed. This report. whether in
whole or in part, any logo, etc.. in advertising or publicity must have CRT's written permission prior to use. This test data is litr exclusive use of the client to who it is addressed and results apply only
to sample(s) tested and does not apply to similar or identical products. This report shall not be reproduced except in full. Testing performed in accordance with ISO 17025. Form Q.S. 43 (10105)
ISO 9001:2000
U`'
Con,m,riod
CRT LABORATORIES, INC.
1680 North Main Street, Orange, CA 92867
(800) 597-LA13S (5227) • (71.4) 283-2032 • Fax (714) 283-1365
www.crtlabs.com • e-mail: crtlabscrtlabs.corn
ASTM Physical & Mechanical • Chemical -Thermal Analysis • IAPMO Cell Class
Geosynthetic Materials • Plumbing & Faucet Assemblies • Resin & Finished Product Testing
FEST REPORT
PAGE
2
OF
FOR: Perma-Liner Industries, Inc.
13000 Automobile Blvd. Suite-300
Clearwater, FL 33762
Tel: (727) 235-1385 / Fax: (727) 507-9849
ATTN: Mr. Michael L. Finocchio
LwR NO.: 18010-R1
DATE. April 21, 2009
TABLE 1.
MATERIAL ID: Charlotte Pipe & Foundry 4" PVC-SDR un-lined & lined (sprayed) pipe
DATA OBTAINED
Pipe size was obtained from referenced ASTM specifications for the PVC sewer pipe. I.D.
was determined by measurements of the product in 4" pipe.
Pipe size (D)
PVC sewer pipe
PVC-FRP sewer pipe
Charlotte 4" nominal
0.330' (3.954")
0.298' (3.578")
Manning coefficients were obtained from Plastic Pipe Institute (PPI) Technical Reports.
Manning coefficients (n)
PVC sewer pipe 0.009-0.010
PVC-FRP sewer pipe 0.010
Hazen Williams coefficients were obtained from LMNO Engineering, Research, and
Software, Ltd. and PPI Technical Reports.
H-W Pipe coefficients (C)
PVC sewer pipe 150
PVC-FRP sewer pipe 150
The friction loss value for insert couplings was obtained from PPI Technical Report Water
Flow Characteristics of Thermoplastic Pipe. These factors occur every so many feet of pipe. The
friction loss was divided by this occurrence to obtain values in ft./ft.
Friction loss
Insert couplings 12D/occurence
PVC sewer pipe 0.0
PVC-FRP sewer pipe 0.0
The slope for a standard installation is 0.25"/' per UPC Code. The friction loss detracts from
the effectiveness of the slope. Without friction loss, the slope is identical. With friction, the slope
effectively decreases as a factor of 1 / (1 + Friction loss).
Effective Slope (S) (0.25"/') 0.02083 / (1 + Friction loss)
PVC sewer pipe 0.02083
PVC-FRP sewer pipe 0.02083
The liability of CRT Labs vaiih respect to the work and report covered herein, shall in no event exceed the amount of the invoice. We recommend consideration that correlative data be generated by other
laboratories in matters of litigation. CRT will retain tested samples for 30 days after testing is completed, unless other arrangements arc agreed upon at. the time order is placed. This report. whetherin
whole or in tart., any loco, etc., in advertising or publicity must have CRT's written permission prior to use. This test data is for exclusive use of the client to who it is addressed and results apply only
to samples) tested and does not apply to similar or identical products. This report shall not be reproduced except in full. Testing performed in accordance with ISO 17025. Pornt Q.S. t ; (I 0/05)
ISO 9001:2000
Committed ro Quin.,
CRT LABORATORIES, INC.
1680 North Main Street, Orange, CA 92867
(800) 597-LABS (5227) • (71.4) 283-2032 ^ Fax (714) 283-1365
www.crtlabs.com • e-mail: crtlabs@crtlabs.com
AS FM Physical Si. Mechanical • Chemical-Therrnal. Analysis • IAPMO Cell Class
Gcosynthetic Materials Plumbing & Faucet Assemblies • Resin & Finished Product Testing
TEST REPORT
FOR
PAGE
3 OF 4
Perma-Liner Industries, Inc.
13000 Automobile Blvd. Suite-300
Clearwater, FL 33762
Tel: (727) 235-1385 / Fax: (727) 507-9849
ATTN: Mr. Michael L. Finocchio
[NANO.:
18010-R1 I,AiF April21, 2009
TABLE 2
FLOW CALCULATIONS
Manning Calculations
Flow (pipes flowing full), q (gpm) = (207.8/n) x D2.667 x S° 5
PVC sewer pipe 155.3 gpm
PVC-FRP sewer pipe 118.8 gpm
Hazen -Williams Calculations
Flow (pipes flowing full), q (gpm) = 193.9 x C x D2.63 x S°54
PVC sewer pipe
PVC-FRP sewer pipe
194.7 gpm
148.9 gpm
Flow Capacity
The samples were tested with water at 73°F. Discharge time was measured with a stopwatch in
order to obtain a valid baseline flow rate. Flow rates were calculated based on the 8.324 lbs/gal
density of water at 73°F.
PVC sewer pipe 212.2 gpm
PVC-FRP sewer pipe 156.4 gpm
The liability of CRT Labs with respect to the work and report covered herein, shall in no event exceed the amount of the invoice. We recominend consideration that correlative data be generated by other
laboratories in matters of litigation. CRT will retain tested samples for 30 days after testing is completed, unless other arran•ucmcnts are agreed upon at the time order is placed. This report, whether in
whole or in p;ut,any logo, etc., in advertising or publicity muse have CRT's written permission prior to use. 'This test data is for exclm.ir e use of the client to who it is addressed and results apply only
to sample(s) tested and does not apply to similar or identical products. This report shall not be reproduced except in full. Testing perlortned in accordance with ISO 17025. Font Q.S. 43 (10/051
ISO 9001:2000
7,
44.
Comm,ned io o„ol:q.
CRT LABORATORIES, INC.
1680 North Main Street, Orange, CA 92867
(800) 597-LABS (5227) • (714) 283-2032 • Fax (714) 283-1365
www.crtlabs.com • e-mail: crtlabs(ii;crtlabs.com
ASTM Physical & Mechanical • Chemical -Thermal Analysis • IAPMO Cell Class
Geosynthetic Materials • Plumbing & Faucet .Assemblies • Resin & Finished Product Testing
TEST REPORT PAGE
FOR:
4
OF 4
Perma-Liner Industries, Inc.
13000 Automobile Blvd. Suite-300
Clearwater, FL 33762
Tel: (727) 235-1385 / Fax: (727) 507-9849
ATTN: Mr. Michael L. Finocchio
RNO
18010-R1 Ditmi. April 21, 2009
TABLE 1
DATA FROM 02/14/2005 (CRT LWR-16149)
Hazen Williams coefficients were obtained
Software, Ltd. and PPI Technical Reports.
H-W Pipe coefficients (C)
Perma-Liner
Vitrified clay
Cast -Iron
from LMNO Engineering,
150
110 — 140 (good condition)
130 (new, unlined)
107 — 113 10 yr. old)
89 —100 (20 yr. old)
75 — 90 (30 yr. old)
64 — 83 (40 yr. old)
Research, and
The slope for a standard installation is 0.25"/' per UPC Code. The friction loss detracts from
the effectiveness of the slope. Without friction loss, slope is the same. With friction, the slope
effectively decreases as a factor of 1 / (1 + Friction loss).
Effective Slope (S) (0.25 "/')
Perma-Liner
Vitrified clay
Cast -Iron
0.02083 / (1 + Friction loss)
0.02083
0.01157
0.01492
The liability of CRT Labs with respect to the work and report covered herein, shall in no event exceed the amount of the invoice. We recommend consideration that correlative data be generated by other
laboratories in matters of litigation. CRT will retain tested samples for 30 days after testing is completed, unless other arrangements are agreed upon at the time order is placed. This report, whether in
whole or in part, any logo, etc., in advertising or publicity must have CRT's written permission prior to use. This test data is for exclusive use of the client to who it is addressed and results apply only
to samplets) tested and does not apply to similar or identical products. This report shall not be reproduced except in full. Testing performed in accordance with 150 17025. Form Q.S. 43 (I0r05)
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0038 DATE: 03/13/14
PROJECT NAME: EVERGREEN BUSINESS CAPITAL
SITE ADDRESS: 13925 INTERURBAN AVE S
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
Building Division II
Publ4\ic WoU
Fire Prevention
Structural
n
Planning Division
Permit Coordinator IN
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 03/18/14
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
DUE DATE: 04/15/14
Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
RESCUE ROOTER
Page 1 of 4
414 Washington State Depot talent of
Labor & Industries
RESCUE ROOTER
Owner or tradesperson
SUGGS, DONALD KEITH
Principals
SUGGS, DONALD KEITH
KARNES, DONALD K
SLOTT, DAVID M
MCMAHON, JAMES T
LEBARON, WILLIAM E (End: 01/21/2003)
BECKMANN, ROBERT F (End: 02/11/2002)
HARDING, BRIAN (End: 04/10/2009)
DUPLESSIS, CARL (End: 04/10/2009)
BOREN, HOWARD (End: 10/09/2006)
ZALIK, STAN (End: 10/09/2006)
965 RIDGE LAKE BLVD.
MEMPHIS, TN 38120
253-872-4902
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
RESCUR*007Q7
Effective — expiration
11/27/2000 — 01 /01 /2016
Bond
WESTCHESTER FIRE INSURANCE CO
Bond account no.
K0750262A
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
01/04/2007 12/03/2006
Insurance
Liberty Mutual Fire Insurance
Policy no.
TB2631508631023
$2,000,000.00
Received by L&I Effective date
09/24/2013 10/01/2013
Expiration date
10/01/2014
Savings
No savings accounts during the previous 6 year period.
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601837949&LIC=RESCUR* 007Q7& S... 03/26/2014