Loading...
HomeMy WebLinkAboutPermit PG14-0071 - CONTINENTAL MILLS - SINKSCONTINENTAL MILLS 18100 ANDOVER PARK W PG1 4-0071 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 3523049121 Permit Number: PG14-0071 Address: 18100 ANDOVER PARK W Issue Date: 5/12/2014 Permit Expires On: 11/8/2014 Project Name: CONTINENTAL MILLS Owner: Name: Address: , , WA, Contact Person: Name: KAREN GEORGE Address: 9322 14TH AVE S , SEATTLE, WA, 98108 Phone: (206) 812-7678 Contractor: Name: P S F MECHANICAL, INC. Phone: (206) 764-9663 Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA, 98108 License No: PSFMEI*090NZ Expiration Date: 10/3/2015 Lender: Name: Address: 11/ DESCRIPTION OF WORK: PLUMBING FOR 3 COMPARTMENT SINKS WITH (1) GARBAGE DISPOSAL. (1) DISHWASHER, (1) FLOOR SINK, (2) COH WATER CONDENSATE HOOKUPS FOR ENVIRONMENTAL CHAMBERS. INCLUDES INSTALLATION OF ZURN GREASE INTERCEPTOR. Valuation of Work: $20,461.00 Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Fees Collected: $182.78 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit4d agrto the conditions attached to this permit. Signature: Print Name: LAx Date: SC ' Z/i% This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: Grease interceptor shall be installed per manufacturer's specification. Applicant shall follow manufacturer's maintenance and cleaning instructions. At any time, the City may inspect the interceptor and require interceptor cleaning service that is more frequent. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaW A .gov I'1> mb G s Permit No Project eta,. matelcar �� at Applicatio l xpire : PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: Tenant Name: King Co Assessor's Tax No.: 7689900010 18100 Andover Park W Continental Mills Suite Number: PROPERTY OWa�1 Name: Segale Properties LLC Address: PO BOX 88028 City: Tukwila State: WA Zip: 98138 Name: Karen George Address: 9322 14th Ave S City: Seattle State: WA Zip: 98108 Phone: (206) 812-7678 Fax: (206) 812-7679 Email: kgeorge@psfmech.com Floor: New Tenant: ❑ Yes m..No PL1lJMBThG CQ4,�, �. TOR 0I AT1 O$ Company Name: PSF Mechanical, Inc. Address: 9322 14th Ave S City: Seattle State: WA Zip: 98108 Phone: (206) 812-7678 Fax: (206) 812-7679 Contr Reg No.: PSFMEI*090NZ Exp Date: 10/03/2015 Tukwila Business License No.: 0102293 Valuation of Project (contractor's bid price): $ 20,461 Scope of Work (please provide detailed information): Plumbing for 3 compartment sinks with (1) garbage disposal. (1) Dishwasher; (1) floor sink; (2) COH water condensate hookups for environmental chambers. Building Use (per Int'l Building Code): Office Building Occupancy (per Int'l Building Code): B2 Utility Purveyor: Water: Sewer H:\Applications\Forms-Applications On Line \2011 Applications \Plumbing Permit Application Revised 8-9-11.docx Revised: August 201 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 Shower, single head trap Sinks 1 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type 1 Qty Dental unit, cuspidor Floor drain 1 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity 1 Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR ZED AGENT: Signature:' ' "?.£ / l-( Print Name Karen George Date: 04/30/2014 Day Telephone: (206) 812-7678 9322 l4th Ave S Seattle WA 98108 Mailing Address: City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY PermitTRAK PAID $182.78 PG14-0071 Address: 18100 ANDOVER PARK W Apn: 3523049121 $182.78 PLUMBING $175.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $108.10 PLAN CHECK FEE R000.322.103.00.00 $35.15 TECHNOLOGY FEE $7.03 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1989 R000.322.900.04.00 $7.03 $182.78 Date. Paid: Thursday, May 01, 2014 Paid By: KAREN GEORGE PSF MECHANICAL IN Pay Method: CREDIT CARD 01755G Printed: Thursday, May 01, 2014 9:27 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6 Ili -O(.j 7i PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670' Permit Inspection Request Line (206) 431-2451 Project: A ti ( i ,. f 1 L 0 f .1 f ' \ t ' I Type of Inspection: Q� r 1. r f ••-•' /A .s(-' / i . �l t' r %' Address: 1 (I'i(J /1 ?11) (71 tAJ Date Called: / 2 �UGd- . r-A Special Instructions: Date anted: L—I‘la _//I "� a.rpi p.m. Requester: Phone No: ®Approved per applicable codes. D Corrections required prior to approval. COMMENTS: n N 4 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Bled.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. . ! CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: OA ; n /A / M, Type of`Ipection: �- _.k`TV Address: j f t 5/ c (.; ,Ql/'2() v1 tr}/ Date Called: �- Special instructions: Date Wanted: .) ,, 1 / - . T (am., p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 11) / A Cl t J r ;, -c ) u r A/ iii I z 1I V v ' k 7 . -r, , f • ) ,1 i r't `t 1 't° 1 1 Inspector: ` r- Date- e_7 3 REINSPECTION FEE REQUIRED: Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit t 4-0 0-11 INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: 6 r-vv V W.), CiC APIrrAl MI i ( Address: 4 10(1 Dz NOV{. Date Called: vv,,,...1 Special instructions J ' n F' l�� t l'' Cj'Requester: 5; C ; S;� W Date Wanted:, t � ! hone V Q. ,..%. e l�c-Q i? Aiv\ proved per applicable codes. Corrections required prior to approval. COMMENTS: d� -ram 5 fi Inspector: pate REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ECEIVED CI MAY 082014 PERMIT CENTER 4-0 LIGHT COMMERCIAL INLET TkJ \vviL FUntiC vonAKs Dimensional Data (inches and [ ram ]) are Subject to Manufacturing Tolerances and Change Without Notice G= WIDTH OF BODY OUTLET GT2700-4 through GT2700-50 LiSGI RECEIVED FILE COPY GT2700 Grease Interceptor MAY 09 2014 CONTINENTAL MILLS -DISH AREA TAG GI-1 INLET Fr4R G= WIDTH cFPUS,ONIPISMNICE APPROVED MY1 GT2700-75 4 GT27{f--'10® 2 2014 City of Tukwila Model Number AB Inlet/Outlet No -Hub Flow Rate G.P.M. [L] Capacity Grease Lbs. [kg] Dimension in I Ivt��� .P Il�ING C`VIS C DIE F G _ GT2700-4 2 [51] 4 [15] 8 [4] 10 [254] 7-1/4 [184] 15-7/8 [403] 9-7/8 [251] GT2700-7 2 [51] 7 [26] 14 [6] 11-1/8 [283] 8-1/8 [206] 17-1/4 [438] 11-7/8 [302] 1 GT2700-15 2 [51] 15 [57] 30 [14] 13-3/8 [340] 9-3/8 [238] 21-1/4 [540] 16-3/4 [425] _ GT2700-25 3 [76] 25 [94] 50 [23] 17 [432] 12-7/16 [316] 26-1/8 [644] 19-7/8 [505] GT2700-35 4 [102] 35 [132] 70 [32] 18-3/4 [476] 14-3/16 [360] 28 [711] 22-1/2 [572] GT2700-50 4 [102] 50 [189] 100 [45] 21-1/2 [546] 16 [406] 29-7/8 [759] 24-1/2 [622] _ GT2700-75 4 [102] 75 [283] 150 [68] 22-3/4 [587] 18-1/2 [470] 36 [914] 28-5/8 [727] GT2700-100 4 [102] 100 [379] 200 [91] 27 [685] 23 [584] 42-3/4 [1086] 33-5/8 [854] GT2700 Grease Interceptor Recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared. Grease trap is corrosion -resistant coated fabricated steel with no -hub connections, flow diffusing baffle, integral trap, and vented inlet flow control device. CORRECTION LTR#_ -J'2 00 . [1 2] x en ion CALCULATION:SINK 2(18"x20"x12") =37 X 0.75=28# 231 14- 007 APPROVED Sizes 4 - 50 Sizes 20 G.P.M. - 50 G.P.M. ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS ♦ 2640 South Work Street ♦ Falconer, NY 14733 Phone:1-800/906-5060 • Fax: 716/665.3126 • World Wide Web: www.zurn.com Rev. B Date:12/20/11 C.N. No. 122581 Dwg. No. 63802 Product No. GT2700 Z lig LIGHT COMMERCIAL GT2700 Grease Interceptor Installation & Cleaning Instructions SINKS APPROVED OPTIONAL P—TRAP VENT (AIR INTAKE) \ CLEANOUT -J �- FLOW ORIFICE PLATE VENT INLET II �I� . OUTLET FLOW CONTROL - • , 'i/r ZURN LIGHT COMM ERCIAL SERIES 2700 INTERCEPTOR w Zurn Light Commercial Series Grease Interceptors #2700 consist of a interceptor rated at ( ) gpm and a properly sized flow control fitting. INSTALLATION 1. Zurn Light Commercial Grease Interceptors should be installed as close as possible to the fixture being served. Always install where there is easy access for cover removal and cleaning. 2. Aflow control must be installed as close as possible to the underside of the fixture. The flow control must be installed with the vent or (air intake) on the downstream side of the orifice plate. The vent connection is positioned to the top of the flow control fitting and piped upward higher than source of water, or to building vent system 3. It is recommended that a cleanout tee be installed before the flow control to access the flow control orifice and clear debris. 4. The cleanout plug should be installed over the outlet of the interceptor. 5. The interceptor is to be installed using no -hub couplings. 5. Outlet piping should be connected to the sanitary drain, and pipe size should be equal to or larger than the inlet piping. Outlet pipe should also be vented so the interceptor is not siphoned. 7. Solid waste should not go into an interceptor. Food grinder waste and other solids should be captured in the sink or by a solids interceptor before reaching the grease interceptor. Form # JS2 Date: 3/13/09 C.N. No. 99791 Rev. F Page 1 of 2 ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS ♦ 2640 South Work Street ♦ Falconer, NY 14733 Phone: 1-8001906-5060 • Fax: 716/665-3126 • World Wide Web: www.zurn.com Z!$ LIGHT COMMERCIAL GT2700 Grease Interceptor Installation & Cleaning Instructions MAINTENANCE General Considerations To obtain optimum operating efficiency of a properly sized and installed PDI certified grease interceptor, a regular schedule of maintenance must be adhered to. Cleaning, All grease interceptors must be cleaned regularly. The frequency of grease removal is dependent upon the capacity of the interceptor and the quantity of grease in wastewater. Check interceptor daily until a grease level of 2" to 3" has been obtained (cleaning level). When the grease removal interval has been determined for a specific installation, regular cleaning at that interval is necessary to maintain the rated efficiency of the interceptor. After the accumulated grease and waste material has been removed, the interceptor should be thoroughly checked to make certain the inlet, outlet, and air relief ports are clear of obstructions. Please follow the steps below when cleaning. 1. Remove the center 3/8" Allen bolt lift handle assembly. 2. Remove cover. 3. Clean out remaining grease. 4. Run water into interceptor to flush. Clean out "outlet" chamber by removing cleanout plug and spraying water down inside. 5. Inspect cover gasket and replace as needed: 6. Replace cover and secure the 3/8" Allen bolt lift handle assembly. Form # JS2 Date: 3/13/09 C.N. No. 99791 Rev. F Page 2 of 2 ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS • 2640 South Work Street ♦ Falconer, NY 14733 Phone: 1-800/906-5060 ♦ Fax: 716/665-3126 • World Wide Web: www.zurn.com City of Tukwila Department of Community Development May 07, 2014 KAREN GEORGE 9322 14TH AVE S SEATTLE, WA 98108 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG14-0071 CONTINENTAL MILLS - 18100 ANDOVER PARK W Dear KAREN GEORGE, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • Please provide a cut sheet for the proposed new grease interceptor together with grease interceptor sizing calculations to assure grease interceptor's adequate capacity. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, File No. PG14-0071 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0071 DATE: 05/08/14 PROJECT NAME: CONTINENTAL MILLS SITE ADDRESS: 18100 ANDOVER PARK W Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Fire Prevention Public Works Structural n Planning Division Permit Coordinator • PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/13/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 06/10/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0071 DATE: 05/01/14 PROJECT NAME: CONTINENTAL MILLS SITE ADDRESS: 18100 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: *Ot.M Building Division II a(A9.4- C-•CC l�-I Public Works Fire Prevention Structural Planning Division Permit Coordinator 11 PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 05/01/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Review ) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/29/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: — %4/ Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: (0, � a T� , //J Project Address: /c/ (00 1.9f-0/pi%L r / r/ 6e) Contact Person: Q"rnes i4 j' ,h/._ Phone Number: 4 04- 74 V ` 96 4 3 Summary of Re Sion: TG IP— 00-7 ;6/�,p[/i `66e.e 7 ,91e. RECEIVED CITV OF TUKWILA MAY 08 2014 +)ERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on P S F MECHANICAL INC Page 1 of 3 0 Washington State Department of Labor & Industries P S F MECHANICAL INC Owner or tradesperson REYNOLDS, JAMES P Principals REYNOLDS, JAMES P, PRESIDENT READ, ANDREW A, PRESIDENT BEARDSLEY, WARREN SCOTT, SECRETARY CRITCHLOW, JAMES D (End: 09/27/2011) Doing business as P S F MECHANICAL INC WA UBI No. 601 318 369 9322 14TH AVE S SEATTLE, WA98108 206-764-9663 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PSFMEI" 090NZ Effective — expiration 08/09/1991-10/03/2015 Bond Active. Meets current requirements. Travelers Cas & Surety Co $12,000.00 Bond account no. 105975899q Received by L&I Effective date 03/13/2014 03/13/2014 Bond history Insurance Liberty Mutual Fire Insurance Policy no. TB2-Z91-452741-023 $1, 000, 000.00 Received by L&I Effective date 09/27/2013 10/01/2013 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 05/12/2014