HomeMy WebLinkAboutPermit PG14-0071 - CONTINENTAL MILLS - SINKSCONTINENTAL MILLS
18100 ANDOVER PARK W
PG1 4-0071
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 3523049121 Permit Number: PG14-0071
Address: 18100 ANDOVER PARK W Issue Date: 5/12/2014
Permit Expires On: 11/8/2014
Project Name: CONTINENTAL MILLS
Owner:
Name:
Address: , , WA,
Contact Person:
Name: KAREN GEORGE
Address: 9322 14TH AVE S , SEATTLE, WA,
98108
Phone: (206) 812-7678
Contractor:
Name: P S F MECHANICAL, INC. Phone: (206) 764-9663
Address: 9322 14TH AVENUE SOUTH , SEATTLE,
WA, 98108
License No: PSFMEI*090NZ Expiration Date: 10/3/2015
Lender:
Name:
Address:
11/
DESCRIPTION OF WORK:
PLUMBING FOR 3 COMPARTMENT SINKS WITH (1) GARBAGE DISPOSAL. (1) DISHWASHER, (1) FLOOR SINK, (2)
COH WATER CONDENSATE HOOKUPS FOR ENVIRONMENTAL CHAMBERS. INCLUDES INSTALLATION OF ZURN
GREASE INTERCEPTOR.
Valuation of Work: $20,461.00
Water District: HIGHLINE
Sewer District: TUKWILA SEWER SERVICE
Fees Collected: $182.78
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Permit Center Authorized Signature:
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit4d agrto the conditions attached to this permit.
Signature:
Print Name:
LAx
Date: SC ' Z/i%
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving
notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be
protected in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for,
or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any
other ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this
permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
15: Grease interceptor shall be installed per manufacturer's specification.
Applicant shall follow manufacturer's maintenance and cleaning instructions.
At any time, the City may inspect the interceptor and require interceptor cleaning service that is more
frequent.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
8004 GROUNDWORK
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaW A .gov
I'1> mb G s Permit No
Project eta,.
matelcar ��
at Applicatio l xpire :
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
Site Address:
Tenant Name:
King Co Assessor's Tax No.: 7689900010
18100 Andover Park W
Continental Mills
Suite Number:
PROPERTY OWa�1
Name: Segale Properties LLC
Address: PO BOX 88028
City: Tukwila State: WA
Zip: 98138
Name: Karen George
Address: 9322 14th Ave S
City: Seattle
State: WA
Zip: 98108
Phone: (206) 812-7678 Fax: (206) 812-7679
Email: kgeorge@psfmech.com
Floor:
New Tenant: ❑ Yes m..No
PL1lJMBThG CQ4,�, �. TOR 0I AT1 O$
Company Name: PSF Mechanical, Inc.
Address: 9322 14th Ave S
City: Seattle State: WA
Zip: 98108
Phone: (206) 812-7678 Fax: (206)
812-7679
Contr Reg No.: PSFMEI*090NZ Exp Date: 10/03/2015
Tukwila Business License No.: 0102293
Valuation of Project (contractor's bid price): $ 20,461
Scope of Work (please provide detailed information):
Plumbing for 3 compartment sinks with (1) garbage disposal.
(1) Dishwasher; (1) floor sink; (2) COH water condensate hookups for environmental chambers.
Building Use (per Int'l Building Code): Office Building
Occupancy (per Int'l Building Code): B2
Utility Purveyor: Water:
Sewer
H:\Applications\Forms-Applications On Line \2011 Applications \Plumbing Permit Application Revised 8-9-11.docx
Revised: August 201
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
1
Shower, single head trap
Sinks
1
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
1
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type 1 Qty
Dental unit, cuspidor
Floor drain
1
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
1
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHOR ZED AGENT:
Signature:' ' "?.£ / l-(
Print Name Karen George
Date: 04/30/2014
Day Telephone: (206) 812-7678
9322 l4th Ave S Seattle WA 98108
Mailing Address: City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT I QUANTITY
PermitTRAK
PAID
$182.78
PG14-0071 Address: 18100 ANDOVER PARK W Apn: 3523049121
$182.78
PLUMBING
$175.75
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$108.10
PLAN CHECK FEE
R000.322.103.00.00
$35.15
TECHNOLOGY FEE
$7.03
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R1989
R000.322.900.04.00
$7.03
$182.78
Date. Paid: Thursday, May 01, 2014
Paid By: KAREN GEORGE PSF MECHANICAL IN
Pay Method: CREDIT CARD 01755G
Printed: Thursday, May 01, 2014 9:27 AM 1 of 1
SYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
P6 Ili -O(.j 7i
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670'
Permit Inspection Request Line (206) 431-2451
Project: A ti (
i ,. f 1
L 0 f .1 f ' \ t ' I
Type of Inspection:
Q� r
1. r f ••-•' /A .s(-' / i . �l t'
r
%'
Address:
1 (I'i(J /1
?11) (71 tAJ
Date Called:
/
2 �UGd- . r-A
Special Instructions:
Date anted:
L—I‘la _//I
"�
a.rpi
p.m.
Requester:
Phone No:
®Approved per applicable codes. D Corrections required prior to approval.
COMMENTS:
n
N
4
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Bled.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO. . !
CITY OF TUKWILA BUILDING DIVISION
6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
OA ; n /A / M,
Type of`Ipection:
�- _.k`TV
Address:
j f
t 5/ c (.; ,Ql/'2() v1 tr}/
Date Called:
�-
Special instructions:
Date Wanted:
.)
,,
1
/ -
.
T
(am.,
p.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
11) / A
Cl t
J r ;, -c ) u r A/ iii
I z 1I V v
' k 7 . -r, , f • ) ,1
i r't `t 1 't°
1
1
Inspector: ` r-
Date- e_7 3
REINSPECTION FEE REQUIRED: Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit t 4-0
0-11
INSPECTI N NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
Type of Inspection:
6 r-vv V W.),
CiC APIrrAl MI i (
Address:
4 10(1 Dz NOV{.
Date Called:
vv,,,...1
Special instructions J ' n F' l�� t
l''
Cj'Requester:
5; C ; S;� W
Date Wanted:, t
� !
hone
V Q. ,..%. e l�c-Q i?
Aiv\
proved per applicable codes. Corrections required prior to approval.
COMMENTS:
d� -ram 5 fi
Inspector:
pate
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
ECEIVED
CI
MAY 082014
PERMIT CENTER
4-0
LIGHT
COMMERCIAL
INLET
TkJ \vviL
FUntiC vonAKs
Dimensional Data (inches and [ ram ]) are Subject to Manufacturing Tolerances and Change Without Notice
G= WIDTH OF BODY OUTLET
GT2700-4 through GT2700-50
LiSGI
RECEIVED
FILE COPY GT2700 Grease Interceptor
MAY 09 2014 CONTINENTAL MILLS -DISH AREA TAG GI-1
INLET
Fr4R
G= WIDTH cFPUS,ONIPISMNICE
APPROVED
MY1
GT2700-75 4 GT27{f--'10® 2 2014
City of Tukwila
Model
Number
AB
Inlet/Outlet
No -Hub
Flow Rate
G.P.M.
[L]
Capacity
Grease
Lbs. [kg]
Dimension
in I Ivt���
.P
Il�ING C`VIS
C
DIE
F
G
_ GT2700-4
2
[51]
4
[15]
8
[4]
10
[254]
7-1/4
[184]
15-7/8
[403]
9-7/8
[251]
GT2700-7
2
[51]
7
[26]
14
[6]
11-1/8
[283]
8-1/8
[206]
17-1/4
[438]
11-7/8
[302]
1 GT2700-15
2
[51]
15
[57]
30
[14]
13-3/8
[340]
9-3/8
[238]
21-1/4
[540]
16-3/4
[425]
_ GT2700-25
3
[76]
25
[94]
50
[23]
17
[432]
12-7/16
[316]
26-1/8
[644]
19-7/8
[505]
GT2700-35
4
[102]
35
[132]
70
[32]
18-3/4
[476]
14-3/16
[360]
28
[711]
22-1/2
[572]
GT2700-50
4
[102]
50
[189]
100
[45]
21-1/2
[546]
16
[406]
29-7/8
[759]
24-1/2
[622]
_ GT2700-75
4
[102]
75
[283]
150
[68]
22-3/4
[587]
18-1/2
[470]
36
[914]
28-5/8
[727]
GT2700-100
4
[102]
100
[379]
200
[91]
27
[685]
23
[584]
42-3/4
[1086]
33-5/8
[854]
GT2700 Grease Interceptor
Recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared.
Grease trap is corrosion -resistant coated fabricated steel with no -hub connections, flow diffusing baffle, integral trap, and
vented inlet flow control device. CORRECTION
LTR#_
-J'2 00 . [1 2] x en ion
CALCULATION:SINK 2(18"x20"x12") =37 X 0.75=28#
231
14- 007
APPROVED
Sizes 4 - 50
Sizes 20 G.P.M. - 50 G.P.M.
ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS ♦ 2640 South Work Street ♦ Falconer, NY 14733
Phone:1-800/906-5060 • Fax: 716/665.3126 • World Wide Web: www.zurn.com
Rev. B Date:12/20/11
C.N. No. 122581
Dwg. No. 63802 Product No. GT2700
Z lig
LIGHT
COMMERCIAL
GT2700
Grease Interceptor Installation & Cleaning Instructions
SINKS
APPROVED
OPTIONAL
P—TRAP
VENT
(AIR INTAKE) \
CLEANOUT
-J �-
FLOW
ORIFICE
PLATE
VENT
INLET II �I� . OUTLET
FLOW CONTROL
-
•
, 'i/r
ZURN LIGHT
COMM ERCIAL
SERIES 2700
INTERCEPTOR
w
Zurn Light Commercial Series Grease Interceptors #2700 consist of a interceptor rated at
( ) gpm and a properly sized flow control fitting.
INSTALLATION
1. Zurn Light Commercial Grease Interceptors
should be installed as close as possible to the
fixture being served. Always install where there
is easy access for cover removal and cleaning.
2. Aflow control must be installed as close as
possible to the underside of the fixture. The
flow control must be installed with the vent or
(air intake) on the downstream side of the orifice
plate. The vent connection is positioned to the
top of the flow control fitting and piped upward
higher than source of water, or to building vent
system
3. It is recommended that a cleanout tee be
installed before the flow control to access the
flow control orifice and clear debris.
4. The cleanout plug should be installed over the
outlet of the interceptor.
5. The interceptor is to be installed using no -hub
couplings.
5. Outlet piping should be connected to the
sanitary drain, and pipe size should be equal
to or larger than the inlet piping. Outlet pipe
should also be vented so the interceptor is not
siphoned.
7. Solid waste should not go into an interceptor.
Food grinder waste and other solids should
be captured in the sink or by a solids interceptor
before reaching the grease interceptor.
Form # JS2 Date: 3/13/09 C.N. No. 99791 Rev. F Page 1 of 2
ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS ♦ 2640 South Work Street ♦ Falconer, NY 14733
Phone: 1-8001906-5060 • Fax: 716/665-3126 • World Wide Web: www.zurn.com
Z!$
LIGHT
COMMERCIAL
GT2700
Grease Interceptor Installation & Cleaning Instructions
MAINTENANCE
General Considerations
To obtain optimum operating efficiency of a properly sized and installed PDI certified grease interceptor,
a regular schedule of maintenance must be adhered to.
Cleaning,
All grease interceptors must be cleaned regularly. The frequency of grease removal is dependent upon the
capacity of the interceptor and the quantity of grease in wastewater. Check interceptor daily until a grease level
of 2" to 3" has been obtained (cleaning level). When the grease removal interval has been determined for a
specific installation, regular cleaning at that interval is necessary to maintain the rated efficiency of the
interceptor. After the accumulated grease and waste material has been removed, the interceptor should be
thoroughly checked to make certain the inlet, outlet, and air relief ports are clear of obstructions.
Please follow the steps below when cleaning.
1. Remove the center 3/8" Allen bolt lift handle assembly.
2. Remove cover.
3. Clean out remaining grease.
4. Run water into interceptor to flush. Clean out "outlet" chamber by removing cleanout plug and
spraying water down inside.
5. Inspect cover gasket and replace as needed:
6. Replace cover and secure the 3/8" Allen bolt lift handle assembly.
Form # JS2 Date: 3/13/09 C.N. No. 99791 Rev. F Page 2 of 2
ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS • 2640 South Work Street ♦ Falconer, NY 14733
Phone: 1-800/906-5060 ♦ Fax: 716/665-3126 • World Wide Web: www.zurn.com
City of Tukwila
Department of Community Development
May 07, 2014
KAREN GEORGE
9322 14TH AVE S
SEATTLE, WA 98108
RE: Correction Letter # 1
PLUMBING/GAS PIPING Permit Application Number PG14-0071
CONTINENTAL MILLS - 18100 ANDOVER PARK W
Dear KAREN GEORGE,
Jim Haggerton, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments.
• Please provide a cut sheet for the proposed new grease interceptor together with grease interceptor sizing
calculations to assure grease interceptor's adequate capacity.
Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-433-7165.
Sincerely,
File No. PG14-0071
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0071 DATE: 05/08/14
PROJECT NAME: CONTINENTAL MILLS
SITE ADDRESS: 18100 ANDOVER PARK W
Original Plan Submittal
X Response to Correction Letter # 1
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
Building Division Fire Prevention
Public Works Structural
n
Planning Division
Permit Coordinator •
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 05/13/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
n
n
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 06/10/14
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0071 DATE: 05/01/14
PROJECT NAME: CONTINENTAL MILLS
SITE ADDRESS: 18100 ANDOVER PARK W
X Original Plan Submittal
Response to Correction Letter #
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
*Ot.M
Building Division II
a(A9.4- C-•CC l�-I
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator 11
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 05/01/14
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
n
Corrections Required
(corrections entered in Review )
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 05/29/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: — %4/ Plan Check/Permit Number:
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: (0, � a T� , //J
Project Address: /c/ (00 1.9f-0/pi%L r / r/ 6e)
Contact Person: Q"rnes i4 j' ,h/._ Phone Number: 4 04- 74 V ` 96 4 3
Summary of Re Sion:
TG IP— 00-7
;6/�,p[/i `66e.e 7 ,91e.
RECEIVED
CITV OF TUKWILA
MAY 08 2014
+)ERMIT CENTER
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in TRAKiT on
P S F MECHANICAL INC
Page 1 of 3
0 Washington State Department of
Labor & Industries
P S F MECHANICAL INC
Owner or tradesperson
REYNOLDS, JAMES P
Principals
REYNOLDS, JAMES P, PRESIDENT
READ, ANDREW A, PRESIDENT
BEARDSLEY, WARREN
SCOTT, SECRETARY
CRITCHLOW, JAMES D
(End: 09/27/2011)
Doing business as
P S F MECHANICAL INC
WA UBI No.
601 318 369
9322 14TH AVE S
SEATTLE, WA98108
206-764-9663
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
PSFMEI" 090NZ
Effective — expiration
08/09/1991-10/03/2015
Bond
Active.
Meets current requirements.
Travelers Cas & Surety Co $12,000.00
Bond account no.
105975899q
Received by L&I Effective date
03/13/2014 03/13/2014
Bond history
Insurance
Liberty Mutual Fire Insurance
Policy no.
TB2-Z91-452741-023
$1, 000, 000.00
Received by L&I Effective date
09/27/2013 10/01/2013
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 05/12/2014