Loading...
HomeMy WebLinkAboutPermit PG14-0072 - STARBUCKS - REDUCED PRESSURE BACKFLOW PREVENTER AND FLOOR SINKSTARBUCKS 17480 SOTJTHCENTER PY PG1 4-0072 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 2623049110 17480 SOUTHCENTER PKWY Project Name: STARBUCKS Permit Number: PG14-0072 Issue Date: 5/12/2014 Permit Expires On: 11/8/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC 3333 NEW HYDE PARK RD #100 PO C/0 KIMCO REALTY CORP, NEW HYDE PK, WA, 11042 STEVE CARNEY 8706 S 222 ST, KENT, WA, 98031 STATE MECHANICAL COMPANY 8706 S 222 ST, KENT, WA, 98031 STATEMC141C7 Phone: (206) 575-7527 Phone: (206) 575-7527 Expiration Date: 9/1/2015 DESCRIPTION OF WORK: INSTALL (1) FLOOR SINK AND RPBP Valuation of Work: $3,980.00 Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $164.58 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: LdA. Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:Date: 3 Print Name: `�� RI/Ak s 1\1- / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. T ( 1 ` -R0C 7-� Project No. Date Application Accepted: Date Application Expires: 5-1- 12 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2623049110 Site Address: 17480 Southcenter Parkway Tenant Name: Starbucks Suite Number: PROPERTY OWNER Name: KIR TUKWILA 050 LLC Address: 301 MINKLER BLVD City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Steve Carney Address: 8706 S 222nd St City: Kent State: WA Zip: 98031 Phone: (206) 575-7527 Fax: (206) 575-7529 Email: stevec@statemech.net Floor: New Tenant: ❑ Yes j..No PLUMBING CONTRACTOR INFORMATION Company Name: State Mechanical Co Address: 8706 S 222nd St City: Kent State: WA Zip: 98031 Phone: (206) 575-7527 Fax: (206) 575-7529 Contr Reg No.: STATEMC141 C7 Exp Date: 09/01/2015 Tukwila Business License No.: BUS-0101359 Valuation of Project (contractor's bid price): $ 3,980 Scope of Work (please provide detailed information): % diu,b ,,, s��1> 1 Oath, -5k eih) gs3P Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Fortes-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Pons. 1 of Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste 1 Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:° '—� Date: 05/01/2014 Print Name: Steve Carney Day Telephone: 206-575-7527 Mailing Address: 8706 S 222nd St Kent WA 98031 City State Zip H:\Applications\Forms-Applications On Line\201 1 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK I QUANTITY I PAID $164.58 PG14-0072 Address: 17480 SOUTHCENTER PKWY Apn: 2623049110 $164.58 PLUMBING $158.25 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $94.10 PLAN CHECK FEE R000.322.103.00.00 $31.65 TECHNOLOGY FEE $6.33 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1993 R000.322.900.04.00 $6.33 $164.58 Date Paid: Thursday, May 01, 2014 Paid By: STATE MECHANICAL CO Pay Method: CHECK 4949 Printed: Thursday, May 01, 2014 11:53 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 36 Permit Inspection Request Line (206) 431-2451 Roil-1-007z Project: 1 1) R C3 �(c 7`C , Type f Inspection: J ` l �i pl C..- Ad rr s iao 5 0 Pi.ki Date Called: Special Instructions: i -�� �" `� Date Wanted: p.m. q: Requeste� Ph ne No: Oct S ate.-aI G7 Approved per applicable codes. tJ Corrections required prior to approval. COMMENTS: ,.. ,,,,,..„...., ,,.., V.. - A., over - "r)1LA ,es,,-- .A) ti.. tali rl rx ) coati,, Cl_A,.,.� :iv4- .l , v/i , �� w Inspector; t i it /. Date;; �- — 1# REINSPECTION FEE REQUIRED. Prior tonext inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0072 DATE: 05/01/14 PROJECT NAME: STARBUCKS SITE ADDRESS: 17480 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A C Building Division um S 7 (1 Public Works Fire Prevention Structural n Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/03/14 Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 STATE MECHANICAL COMPANY Page 1 of 3 0 Washington State Department of Labor & industries STATE MECHANICAL COMPANY Owner or tradesperson PLATZ, GERRICK D Principals PLATZ, GERRICK D, PRESIDENT LYNCH, JOHN MICHAEL, VICE PRESIDENT DEWITT, RALPH E (End: 12/18/2012) Doing business as STATE MECHANICAL COMPANY WA UBI No. 600 611 697 8706 S 222nd St KENT, WA 98031 206-575-7527 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. STATEMC141 C7 Effective — expiration 02/27/1986— 09/01/2015 Bond TRAVELERS CAS & SURETY CO Bond account no. 200686359 $6,000.00 Received by L&I Effective date 08/14/2001 07/27/2001 Insurance James River Ins Co $1,000,000.00 Policy no. 000590200 Received by L&I Effective date 08/22/2013 08/23/2013 Expiration date 08/23/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600611697&LIC=STATEMC 141 C7&SAW= 05/12/2014 PLUMBING SYMBOLS LEGENDPLUMBING ABBREVIATIONS GENERAL PLUMBING NOTES 3PL THIRD PARTY5. LOGISTICS GC GENERAL CONTRACTOR GEC! GROUND FAULT AFF ABOVE FINISHED FLOOR CIRCUIT INTERRUPTER AHJ AUTHORITIES HAVING JURISDICTION GW GREASE WASTE APPROX APPROXIMATE HR HOUR HVAC HEATING, VENTILATION BLDG BUILDING AND AIR CONDITIONING HW HOT WATER CLG CEILING HS HANDSINK CONST CONSTRUCTION HWS HOT WATER SUPPLY CW DOMESTIC COLD.WATER HWR HOT WATER RETURN CXA COMMISSIONING AGENT LL LANDLORD DEG DEGREES LV LOW VOLTAGE DTL DETAIL MAX MAXIMUM DN DOWN MACH MECHANICAL DWG(S) DRAWING(S) MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL EA EACH MEP MECHANICAL, ELECTRICAL EC ELECTRICAL CONTRACTOR AND PLUMBING ELEC ELECTRICAL MFG MANUFACTURER EM EMERGENCY MIN MINIMUM (E) OR (EX) EXISTING MS MOP SINK EXT EXTERIOR NL NIGHTUGHT FD FLOOR DRAT N NTS NOT TO SCALE FS FLOOR SINK F&I FURNISH & INSTALL PC PLUMBING CONTRACTOR FLR FLOOR PS PREP SINK FT FOOT/FEET POC POINT OF CONNECTION MO FLOOR CLEANOUT PM PROJECT MANAGER REF REFERENCE. REQ D REQUIRED O O REV REVISION/REVISION SHT SHEET SPECS SPECIFICATION(S) SF SQUARE FEET SS STAINLESS STEEL TEL TELEPHONE TEMP TEMPORARY TYP TYPICAL TMV TEMPERATURE MIXING VALVE TW TEMPERED HOT WATER UNO UNLESS NOTED OTHERWISE V VENT W SANITARY WASTE WH WATER HEATER WP WEATHER PROOF WCO WALL CLEANOUT CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY 1. PC SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES AND'BE ; RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO BID TO REVEAL THE FULL OTHER TRADES, AND,NOTIFY STARBUCKS' CM OF ANY DISCREPANCIES PRIOR TO ALL PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SCOPE OF WORK. IN ADDITION, THE PC SHALL THOROUGHLY EXAMINE , AREAS WHERE EQUIPMENT, PIPING, AND FIXTURES WILL BE INSTALLED AND WILL SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM FROM REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ACTUAL BUILDING DIMENSIONS. PLUMBING WORK PRIOR TO BID. 6. THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK WITH OTHER 2. PC SHALL COORDINATE WITH THE GC TO PATCH AND REPAIR ALL EXISTING TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER WALLS FLOORS CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT DRAWINGS. SEE ARCH. DRAWINGS FOR FIXTURES IN CASEWORK AND PLUMBING DETAILS. MAY BECOME DAMAGED DURING THE COURSE OF WORK. 7. UNLESS OTHERWISE NOTED(SEE ARCH. SHEETS), THE CONTRACTOR SHALL REMOVE ALL 3. EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR AREA EXISTING PLUMBING FIXTURES INCLUDING PIPING AND ALL OTHER MISC. DEVICES AS BY THE GC THAT IS NOT BEING SALVAGED OR REUSED. UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT CABINETS/DEVICES AND E INSPECTED WHERE APPROVED BY STARBUCKS CM. IF ROUTED THROUGH CABINETS IT EQUIPMENT FIXTURES INDICATED ON DRAWINGS TO BE REUSED SHALL B SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE PROTECTED FROM AND IF DE�ECTIVE, REPLACED. COORD. WITH GC AND STARBUCKS CM. DAMAGE. 8. ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM STRUCTURE 4. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS). ARRANGEMENT OF SYSTEM(5). F&I ALL COMPONENTS NEEDED WHETHER TALL EXISTING PIPING AND DEVICES ARE INDICATED OR NOT TO PROVIDE A COMPLETE AND OPERATING SYSTEM. 9• ALL IS NEW UNLESS OTHERWISE NOTED. NO SHOWN. MAINTAIN CONNECTIONS TO EXISTING FIXTURES AS NEEDED (NOT NECESSARILY SHOWN). S OR W SANITARYLOWSLAB WASTE:PIPING I�I BV BALL VALVE - BELOW (U.N.O.) GV —` — V SANITARYVENT PIPING D4 GATE VALVE GW GW GREASE WASTE PIPING J CH. V CHECK VALVE BELOW SLAB (U.N.0.) PRV PRESSURE REDUCING VALVE CD CD CONDENSATE DRAIN RV RELIEF VALVE CW COLD WATER PIPING' BFP BACKFLOW PREVENTERDIRECTED HW HOT WATER PIPING HB HOSE BIBS CWF COLD WATER FILTERED CWF Q SHOCK ABSORBER CWN CWN COLD WATER NANO FILTERED STRAINER CWS CWS COLD WATER SOFTENED WCO WALL CLEANOUT TW TEMPERED HOT WATER • G G GAS PIPING 0 imi FCO FLOOR CLEANOUT nu Q 4. FS FLOOR SINK WM WATER METER POC POINT OF CONNECTION STOP VALVE AT FIXTURE SEPARATE PERMIT REQUIRED FOR: �[8't�tartkal ❑Plumbing j Piping City of Tukwila BUILDING DIVISION NOTE SOME SPECIFICATION SECTIONS REVISION$ INDICATED ON THIS SHEET MAY NOT APPLY TO NO THIS EXISTING STORE'S RENOVATION SCOPE. Changes sha!! be made to the :vet wTork wiihout rior approval CONTRACTOR SHALL VERIFY RENOVATION p SCOPE AND APPLY APPROPRIATE Tukwila Building Division. SPECIFICATION SECTION REQUIREMENTS. NO'p'E: Revisions will require a new plan submits► and mayg CONFIRM WITH CM. include additional plan review uses, PLUMBING SPECIFICATIONS BASIC MATERIALS AND METHODS PIPING INSULATION GENERAL SPECIFICATION NOTES MATERIALS PROVIDE ALL NEW MATERIAL AND FIXTURES UNLESS NOTED OTHERWISE. ALL FIXTURES AND MATERIALS SHALL BE LABELED AND LISTED WHERE REQUIRED BY CODE AND AHJ. CUTTING, CORING AND FITTING PERFORM REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE FIXTURE. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE ARCHITECT, CONSTRUCTION MANAGER, GC, AND/OR OWNER. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. HANGERS & SUPPORTS THE PLUMBING CONTRACTOR SHALL F&I ALL PIPE SUPPORTS NEEDED FOR EQUIPMENT AND MATERIAL. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS SPACED NOT MORE THAN 10 FEET 0.C. FOR PIPES 1-1/4" AND LARGER, AND 8 FEET 0.C. FOR PIPES SMALLER THAN 1-1/4" AND AT EACH JOINT FOR SOIL OR WASTE PIPE. ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE NEEDED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED WITH GALVANIZED COATINGS; NONMETALLIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPER TUBING. CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPING UP TO AND INCLUDING 1-1/2". WELD PIPING USE NON -LEAD, NON -ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. INSTALLATION INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" CLEANING SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL CHANGES IN DIREC110N AND BRANCH CONNECTIONS. INSTALL FITTINGS FOR PASSING THROUGH CONCRETE AND MASONRY WALLS, SLEEVES FOR C GYPSUM-BOARD PARTITIONS, CONCRETE FLOOR, AND ROOF SLABS/STRUCTURE. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION MTH FIRESTOPPING SEALANT MATERIAL MEETING CODE, AHJ, AND ARCHITECT'SREQUIREMENTS. LINES SHALL BELAID IN SEPARATETRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL. EQUIPMENT THE PLUMBING CONTRACTOR SHALL VERIFY ANY EQUIPMENT LOCATION AND SIZES REQUIRING PLUMBING CONNECTION(S) WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. CLEANOUTS F&I J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS AND WHERE NEEDED IN ALL SOIL, WASTE, AND DRAIN LINES. IN AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESILIENT FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. WHERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS COVERS. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY AHJ. TEST WATER PURITY ACCORDING TO AHJ AND SUBMIT CERTIFIED TEST RESULTS TO AHJ FOR REVIEW AND APPROVAL. SOIL, WASTE AND VENT PIPING SOIL, WASTE AND VENT PIPING 10"AND SMALLER SHALL BE SERVICE WEIGHT,- HUBLESS, CAST IRON RIPE AND FITTINGS WITH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB -TYPE PIPE AND FITTINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODES OR AHJ. SCHEDULE 40 ABS AND FITTINGS WITH SOLVENT WELD MAY BE SUBSTITUTED FOR SOIL, WASTE AND VENT PIPING, ABOVE AND BELOW GROUND IF ALLOWED BY AHJ. HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4 INCH PER FOOT WHERE POSSIBLE BUT IN NO CASE LESS THAN 1/8" PER FOOT. APPLY TO BUILDING DEPARTMENT FOR VARIANCE IF 1/8" IS NEEDED. COORDINATE WITH AHJ FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAINS. ` PROVIDE PIPED DRAIN TO SANITARY IF REQUIRED BY AHJ. RELOCATE ANY VENTS NECESSARY TO GIVE 10 FOOT CLEARANCE FROM HVAC INTAKE. COORDINATE WITH HVAC CONTRACTOR, DOMESTIC WATER PIPING 2" AND SMALLER SHALL BE COPPER TUBE WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH LEAD FREE SOLDER. PROVIDE TYPE 1" COPPER TUBE ABOVE GROUND AND TYPE "K" BELOW GROUND. CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL F&I CONDENSATE DRAINS FOR AIR HANDLING UNITS, REFRIGERATION EQUIPMENT, & ANY OTHER APPLICABLE EQUIPMENT. CONDENSATE DRAINAGE PIPING SHALL BE TYPE IV COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. NATURAL GAS PIPING 40,ICE ISSC, BLACKPTISTEEL PIPE. PROVIDE GAS PIPING SHALLRTBLOCKING SCHEDULE ROOF THAT PIPING SUPPORT ON THAT IS COMPATIBLE WITH ROOFING SYSTEM AND PIPE HANGERS/STRAPS PER CODE. WATER PIPING PROVIDE THERMAL INSULATION ON ALL HOT & COLD WATER, AND HORIZONTAL WASTE PIPING IN CEILING SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR AREAS. USE SELF-SEALING CLOSED CELL FOAM DR JACKETED FIBERGLASS INSULATION WITH MANUFACTURER APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL HAVE A FLAME SPREAD INDEX NOT MORE THAN 25 A SMOKE DEVELOPED INDEX NOT MORE THAN 50 OR 50 FOR FUEL CONTRIBUTED. UNLESS OTHERWISE REQUIRED BY THE AHJ OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: PIPE SIZE INSULATION THICKNESS NOTE: "CONTRACTOR" MEANS ANYWHERE IN THE EQUIPMENT HAS BEEN CONTRACTORS TO "PROVIDE", AND "INSTALL" DOCUMENTS AND MAKE A COMPLETE SCOPE THE INTENT OF THE COMPLETE AND FULLY CONTRACTOR SHALL "PLUMBING CONTRACTOR" WHEN REFERENCED PLUMBING CONSTRUCTION DOCUMENTS UNLESS COORDINATED BETWEEN THE PLUMBING BE PROVIDED BY THE GENERAL CONTRACTOR. MEANS ALL ITEMS CALLED OUT IN ANY ADDITIONAL ITEMS NOT CALLED OUT BUT AND OPERATIONAL SYSTEM. SPECIFICATIONS AND THE DRAWINGS IS TO OPERATIONAL PLUMBING SYSTEM. THE FURNISH AND INSTALL ALL LABOR, MATERIAL WORK AND AND GENERAL "NEEDED", THE CONTRACT REQUIRED TO PROVIDE A PLUMBING AND LESS THAN OR 1" EQUAL TO 1-1/4" = " " 1-1/2 DIA. OR GREATER = 1-1/2 INSULATION VALUE = k VALUE NOT EXCEEDING 0.27 BTU * INCH/h*ft * F SAFETY COVERS INSTALL NO -SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOF STRAP AT EXPOSED PIPING UNDER ADA SINKS AS FURNISHED BY STARBUCKS. BIN DRAINS " INSULATE ICE BIN COPPER DRAIN LINES WITH 1/2 THICK, SELF-SEALING, SECTIONAL, CLOSED CELL FOAM. / RAIN CONDUCTORS INSULATE RAIN WATER CONDUCTORS WHICH PASS THROUGH OCCUPIED AREAS WITH 1/2 " THICK FIBERGLASS. HVACWARRANTY INSULATE PIPING COOLING COIL PIPING AND CONDENSATE PIPING WITH CODE & MANUFACTURER SIZED, SELF SEALING, CLOSED CELL FOAM. INSULATE HVAC CONDENSOR WATER SUPPLY & RETURN PIPING SYSTEMS AND CONDENSATE PIPING WITH CODE & MANUFACTURER SIZED, HEAVY DUTY, SELF SEALING, JACKETED FIBERGLASS. EQUIPMENT NECESSARY STANDARDS EQUIPMENT AND MATERIALS OF ASME, ASTM, OTHER APPLICABLE ASSEMBLY. CODES PERFORM ALL WORK STATE AND LOCAL IN COMPLIANCE WITH BETWEEN THE DRAWINGS, THE' MOST STRINGENT APPLY. THE PLUMBING AND SPECIFICATIONS PERMITS AND FEES THE PLUMBING CONTRACTOR FEES AND INSPECTIONS WORK. THE PLUMBING CONTRACTOR TO BE FREE OF DEFECTS ONE (1) YEAR FROM WILL REPAIR OR CHARGE AND RESTORE OF REPAIRING DEFECTIVE TO COMPLETE THE PLUMBING WORK. SHALL CONFORM WITH:APPROPRIATE UL, NEMA, NSF, ANSI, ASHRAE, NEPA, IAPMO, AGENCY AS APPLICABLE TO EACH INDIVIDUAL IN ACCORDANCE WITH THE CURRENT PLUMBING CODES/ORDINANCES AND AHJ. ALL WORK BUILDING OWNER'S CRITERIA. IN CASE OF SPECIFICATIONS, CODES, ORDINANCES, STANDARD (IN THE OPINION OF THE ENGINEER) CONTRACTOR SHALL SATISFY CODE, AHJ, AS A MINIMUM STANDARD WITHOUT ANY SHALL PROCURE AND PAY FOR NECESSARY TO COMPLETE THE PLUMBING SHALL UNCONDITIONALLY WARRANT IN MATERIAL AND WORKMANSHIP FOR THE DATE OF FINAL ACCEPTANCE BY STARBUCKS REPLACE ANY DEFECTIVE WORK PROMPTLY AND ANY OTHER EXISTING WORK DAMAGED MATERIALS AND WORKMANSHIP. PROVISIONS OR ICBO, OR UNIT OR CODE, SHALL ALSO BE CONFLICT AND AHJ, SHALL DRAWINGS, EXTRA COST. ALL PERMITS, SCOPE OF ALL WORK A PERIOD OF AND WITHOUT IN THE COURSE VALVES GENERAL PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NO1ED) BEIINEEN VALVE AND EQUIPMENT IN ACCORDANCE WIN MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. PROVIDE STOP VALVES FOR ALL EQUIPMENT WHETHER JON NE DRAWINGSVALVES SHALL BE LISTED/APPROVED FOR USE SHOWN BYAND REQUIREMENTS. R MEN S VALVES PROVIDE VALVES FOR WORKING PRESSURE IN WATER PIPING OF 125 PSI OR GREATER. UNLESS NOTED OTHERWISE VALVES SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: VALVE TYPE DESCRIPTION PLUMBING FIXTURES THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT FIRE SPRINKLER SYSTEM INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. REFER TO SCHEDULES ON DRAWINGS (PLUMBING & ARCH. SCHEDULES) FORA DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC" UNDER THE "RESPONSIBILITY" COLUMN. ANY DISCREPANCIES ABOUT CONFIRM IF THERE IS AN EXISTING FIRE SPRINKLER SYSTEM MODIFY/EXTEND' AS MAY BE NEEDED FOR THE RENOVATION SHOWN). COORDINATE WITH THE LANDLORD/BUILDING OWNER FOR SPRINKLER DESIGN BUILD REQUIREMENTS. AND (ALL NOT (BEFORE BD) CHECK VALVE (UP TO 2"): BRONZE,HORIZ.SWING,Y-PATIERN,RENEWABLE SEAT/DISC BALL VALVE (UP TO 3"): BRASS,FULL PORT,QUARTER TURN GATE VALVE (UP TO 3"): BRONZE,NON-RISING STEM,SOLID WEDGE TEMPERATURE AND RATED FOR POTABLE WATER HEATING STORAGE PRESSURE RELIEF VALVE: VESSEL WITH SAFETY CERTIFICATION PER AHJ WATER HAMMER ARRESTOR: PRE -CHARGED, SEALED CHAMBER BACKFLOW PREVENTER DOUBLE CHECK VALVE ASSEMBLY WM-I UNION (WHOLE -HOUSE): BALL VALVES AND SAFETY CERTIFICATION PER AHJ BACKFLOW PREVENTER DOUBLE CHECK VALVE ASSEMBLY WITH SAFETY1� (SINGLE DEVICE): CERTIFICATION PER AHJnll�t VACUUM RELIEF VALVE: BRASS BODY AND STAINLESS STEEL INTERNALS PRESSURE REDUCING VALVE: BRONZE 25 TO 75 PSI REDUCED PRESSURE RANGE AND UPSTREAM/DOWNSTREAM PRESSURE GAUGES TRAP SEAL PRIMER: BRONZE,PRESSURE BASED AUTOMATIC PRIMING WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO THE ATTENTION OF THE GC PRIOR TO BID. THE GC SHALL COORDINATE WITH STARBUCKS FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO PLUMBING SHEET INDEX �/ SUPPLIES. �'�' No. 007Z Pian I'6vi81N approvalIs sublet berrors and missions. , kpre: vaI of construction downs* not does authorize CITY P-0001 PLUMBING SPECIFICATIONS P-1101 PLUMBING SUPPLY PLAN &SCHEDULE P-1102 PLUMBING WASTE/VENT PLAN P-5001 PLUMBING DETAILS RECEIVED ECOF IVED A MAY 01 2014 PERMIT CENTER the: '1�1�c�$60t1 of at1Y S� t10�8 � �' R@C�'i�3� 1 pp 1 Alida� a m �•� 6 — � .r REVIEWED FOR 3 . SUPPLY WATER SERVICE IF WATER PRESSURE PROVIDE A PRESSURE REGULATOR SUPPLIED NI MAIN SUPPLYI TO REDUCE WATER PRESSURE IN PROVIDE BACKFLOW PREVENTION ON WATER SERVICE IF REQUIRED BY LOCAL CODE THERMOSTATIC MIXING VALVE PROVIDE A SINGLE THERMOSTATIC MIXING VALVE (TMV) LOCATED AT HOT WATER TANK AND SET FOR 110' (OR AS REQUIRED BY AHJ) TO SERVE HAND SINKS. MIXINGTv VALVE TO BE INSTALLED PER MANUFACTURER'S REQUIREMENTS WITH CHECK VALVES AT SUPPLY INLETS. FOR REMODELS, PROVIDE MIXING VALVE UNDER HAND SINK(S) IF THERE IS NOT EXISTING TMV AND PIPING. � � OMIT:, /� F CODE COMPLIANCE APPROVED "` , CRY Ofi' BUILDING t31VISiUN _ - MAY 0 8 2014 . City of Tukwda .. �� y` 41 , . . 9— BUILDING DIVISION I�� 02011 Starbucks Coffee Company Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. PIENSCH ENOINEE IN «C 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 360-863-6677 FX:360-863-3565 rensch.eng i neeri ng©comcast.net Revision Schedule Rev Date By Description Project Name: PARKWAY SUPERCENTER Project Address: 17480 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON Store #: Project #: 3267 04447-027 Issue Date: 2-14-2014 Sbux Design Manager: Christy Monge Designed by: Bill Bennecker Drawn by: Dave Carlson Checked by: Chris Rensch Sheet Title: Plumbing Specifications Scale: Sheet Number: P-0001 4 Plumbing Fixture Schedule Design ID Count Description Responsibility Comments Cold Water Service 10153 1 Faucet - Water Tower - 12in SB Food Service Equipment 10874 1 Faucet - Hot Water Dispenser Gooseneck SB Other Plumbing Fixtures 10215 1 Faucet - Double Laboratory with Swing Spout SB 10294 1 12" Square Floor Sink SB 10726 1 Square Floor Sink Grate SB 11003 1 Faucet - Push Button SB Metered PLUMBING SUPPLY PLAN 0 1 2 3 4 8 12 GENERAL SUPPLY NOTES SEE P-0001 GENERAL PLUMBING NOTES FOR FURTHER REQUIREMENTS. COLD WATER SUPPLY LINES INSIDE CASEWORK & BAR AREA TO BE COVERED WITH 1/2" THICK SELF SEAUNG, SECTIONAL CLOSED -CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. NOTE NOT USED. 0 STOP VALVES SHALL BE F&I AT ALL PLUMBING FIXTURES EVEN IF NOT SHOWN IN PLAN. 0E RUN ALL PIPING CONCEALED. 0 VERIFY BACKFLOW PREVENTER REQUIREMENTS OF EQUIPMENT WITH INSPECTOR BEFORE BID. BACKFLOW PREVENTERS SHALL BE FURNISHED, INSTALLED, & INSPECTED PER CODE & AHJ (NOT NECESSARILY SHOWN). 0 SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ALL EXPOSED PIPES. PAINTING OF PIPES SHALL INCLUDE ALL NEW AND EXISTING PIPES. SUPPLY KEY NOTES 01 CONNECT TO EXISTING CW, CWF & HW PIPES OF EQUIVALENT SIZE (FIELD VERIFY). 2 NOTE NOT USED. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 NOTE NOT USED. ESPRESSO MACHINE: 1/2" CWF SUPPLY. CONNECT BRAIDED STAINLESS STEEL HOSE FROM SHUT-OFF TO PUMP & THEN TO ESPRESSO MACHINE WATER INLET. DIPPERWELL FAUCET: 1/2" CW SUPPLY. HOT TAP: 3/8" CWF SUPPLY. REDUCE TO 1/4 " AT UNIT. WATER TOWER FAUCET: 3/8" CWF SUPPLY. NOTE NOT USED. BACKFLOW PREVENTER: F&I AHJ APPROVED BACKFLOW PREVENTER IN EACH LINE. 3/4" CW STUB -OUT THRU WALL W/BALL SHUT-OFF VALVE. SUPPLY 3/4" CWF STUB -OUT THRU WALL W/BALL SHUT-OFF VALVE. 1/2" HW STUB -OUT THRU WALL W/BALL SHUT-OFF VALVE. NOTE NOT USED. PITCHER RINSER FAUCET (2 HANDLE): 1/2" HW & CW SUPPLY. F&I BACKFLOW PREVENTERS. NOTE NOT USED. ROUTE PIPE(S) CONCEALED BELOW COUNTER & TIGHT TO BAR WALL (COORD. W GC) NOTE NOT USED. SEE SHEET P-1102 FOR TAG AND LOCATION. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 08 2014 City of Tukwila BUILDING DIVISION r7�-001� RECEIVED CITY OF TUKWILA MAY 01 2014 PERMIT CENTER 02011 Starbucks Coffee Company Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENSCH EINIGINEERIN91 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 360-863-6677 FX:360-863-3565 rensch.eng i neeri ng@com cast.net Revision Schedule Rev Date By Description Project Name: PARKWAY SUPERCENTER Project Address: 17480 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: 3267 04447-027 2-14-2014 Christy Monge Bill Bennecker Dave Carlson Chris Rensch Sheet Title: Plumbing Supply Plan & Schedule Scale: Sheet Number: P-1101 3X2 INDIRECT DRAIN HUB i PLUMBING WASTE / VENT PLAN 3 12 GENERAL WASTE/VENT NOTES SEE P-0 ENTSENERAL PLUMBING NOTES FOR FURTHER 0 ALL IS NEW UNLESS OTHERWISE NOTED. QWHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO A FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING ALL LINES ABOVE THE DRAIN. V F&I ALL NEEDED INDIRECT DRAINS PER CODE (NOT ALL SHOWN). INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE W/AN AIR GAP PER CODE. 0 NOTE NOT USED. ALL P-TRAPS (WITH INTEGRAL UNION) & TAIL PIECE TO BE TYPE ABS UP TO AND INCLUDING THREADED COUPLING TO BASKET STRAINERS. 0 F&I WALL CLEANOUTS AT ALL SINKS AND AS NEEDED AND PER CODE (NOT ALL SHOWN). (� F&I ANY NEEDED INDIRECT PIPING FROM BACKFLOW DEVICES TO v FLOOR SINKS (TYP)(NOT SHOWN). 0 0 KEY NOTES CONNECT TO EXISTING 3"W AND 2"V BELOW SLAB (CONFIRM). POINT OF CONNECTION IS SHOWN SCHEMATICALLY TO SHOW DESIGN INTENT. CONTRACTOR SHALL RUN CAMERA SCOPE THROUGH LINE PRIOR TO SAW CUTTING TO VERIFY EXACT WASTE LINE SIZES, INVERTS & ROUTES. COORDINATE WITH STARBUCKS CM WITH ANY DISCREPANCIES. NOTE NOT USED. NOTE NOT USED. ESPRESSO MACHINE: PROVIDE FEMALE PIPE THREAD FROM ESPRESSO MACHINE DRAIN TRAY TO INDIRECT HUB DRAIN. 2" INDIRECT LINE FROM HUB DRAIN TO FLOOR SINK. NOTE NOT USED. NOTE NOT USED. 10 ESP SINK: PROVIDE 1-1/2" INDIRECT DRAIN TO FLOOR SINK. 11 FLOOR SINK: PROVIDE 3" WASTE/2"V. 001) REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 8 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 01. 2014 PERMIT CENTER 02011 Starbucks Coffee Company Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENSCH ENSINEE INti c« 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH:360-863-6677 FX:360-863-3565 rensch.engineering@comcast.net Revision Schedule Rev Date By Description Project Name: PARKWAY SUPERCENTER Project Address: 17480 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: 3267 04447-027 2-14-2014 Christy Monge Bill Bennecker Dave Carlson Chris Rensch Sheet Title: Scale Plumbing Waste / Vent Plan Sheet Number: P-1102 FLOOR SINK SET FLUSH W/TOP FIN. FLR. (CONTRACTOR TO CONFIRM WITH AHJ IF FLOOR SINK IS TO BE ELEVATED ABOVE SLAB) CAULK JOINT A• 0 • v A• 0. - • • a ` a ' . • ♦ • ♦ - • • a 1Ati. e.4. ate. • o • POSCe 1 -)( ?): &CO-> J0O;4)0 ---- 000°oc Oo -O0o 0000 0o O 0 000 PO �Doa Q oc°oOo� Soo r, 0y — QOo THIN SET CERAMIC 11LE, TYP. COORDINATE WITH GENERAL ON TYPE OF FLOORING AND FLOOR SYSTEM, ETC. CONC. INFILL 0 TRENCH FOR BELOW GRADE UTILITIES FLOOR SINK N.T.S. GRAVEL BACKFILL (CONFIRM BUILDING IS SLAB ON GRADE BEFORE BID) NO HUB CONNECTION 3" WASTE TO DRAIN DETAIL SINK/ICE BIN ABS THREADED COUPLING TO BASKET STRAINER CLEANOUTS AT ALL CHANGES----" —4- IN DIRECTION (OR AS ALLOWED BY AHJ) ABS DWV FITTINGS (TYP.) PIPE HANGER SUPPORT (OR PIPE CLAMP SUPPORT AS NEEDED. ABS INDIRECT DRAIN PIPE (SEE PLAN FOR SIZES). &I ADDITIONAL OFFSETS AS MAY BE NEEDED. PIPE CLAMP SUPPORT AT DRAIN TERMINATION (& BLOCKING -NOT SHOWN) DISCHARGE INTO OPEN AREA Mg MO OF FLOOR SINK W/2" AIR GAP �--- FLOOR FLOOR SINK NOTES: 1. F&I ALL WORK PER CODE AND AHJ REQUIREMENTS EVEN IF NOT SPECIFICALLY SHOWN. 2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPING SHALL BE MOUNTED OFF THE FLOOR FOR CLEANING PURPOSES. 3. ALL INDIRECT DRAIN DISCHARGES SHALL OCCUR OVER CLEAR AREA OF FLOOR SINK AND NOT OVER GRATE. 4. CSLOPE ODE ALL PIPERSJP (RNOCODE T SHOWN)AND F&I TRAPPED INDIRECT DRAIN AND VENT IF REQUIRED BY SINK INDIRECT DRAIN DETAIL NTS VENT IF REQUIRED BY CODE AHJ TO OUTSIDE(DO NOT CONNECT TO ANY SEWER VENT) PROVIDE CLEANOUTS IN TURNS/ENDS OF PIPE.. SLOPE PIPE PER CODE. SEE PLAN(S) FOR SIZE. NOTES: 1. F&I ALL WORK PER CODE AND AHJ REQUIREMENTS �,%r FLOOR SINK(OR FUNNEL EVEN IF NOT SPECIFICALLY SHOWN. DRAIN) 2. ALL PIPES SHALL BE RIGIDLY SUPPORTED AND ALL SUPPORTS & PIPES SHALL BE MOUNTED OFF THE FLOOR FOR CLEANING PURPOSES. 3. ALL FLEXIBLE INDIRECT DRAIN LINES FOR APPLIANCES SHALL BE INSTALLED PER CODE/AHJ AND MANUF. REQUIREMENTS. SUPPORT LINES SO THERE ARE NO SAGS OR DIPS IN LINE. CONNECT TO EQUIPMENT INDIRECT DRAINS -TRAP IF REQUIRED PER CODE OR AHJ. CONDENSATE DRAINS -TRAP REQUIRED INSTALL PER MANUF./CODE REQUIREMENTS. PIPE MATERIAL SHALL BE PER THESE PLANS AND/OR PER CODE. USE DWV FITTINGS IF REQUIRED BY CODE/AHJ. DISCHARGE INTO OPEN AREA OF FLOOR SINK W/2" AIR GAP (OR AS ALLOWED BY CODE) TYPICAL CONDENSATE/EQUIPMENT INDIRECT DRAIN DETAIL NTS NOTE: SCHEMATIC - ADAPT AS NEEDED FOR EXACT SITUATION. SEE ESPRESSO MACHINE PIPING CONNECTION DETAIL (WHERE APPLICABLE) WATER TOWER -- SHOT TAP FAUCET ESP SINK RIGHT HAND SHOWN (LEFT HAND SIM.) BACKFLOW PREVENTER (TYP.) METERED FAUCET SHUT OFF VALVE (TYP.) ESP SINK PIPING DETAIL N.T.S. BRAIDED STAINLESS STEEL HOSE. 9/16-24 UNEF COMPRESSION CONNECTION 150 PSIG MIN. RATING. (TYP. COUNTER TOP WATER PUMP. INSTALL TO ALLOW ACCESS TO INTEGRAL PUMP FILTER. SEE PUMP ATTACHMENT DETAIL IN ARCH PLANS (TYP. 2) / BRAIDED STAINLESS STEEL HOSE. 9/16-24 UNEF COMPRESSION CONNECTION 150PSIG MIN. RATING. (TYP. 2) 1/2" NPT TO HOSE COMPRESSION CONNECTION (TYP. 2) 1/2" BALL VALVE. (TYP. 2) FLOOR PUMP ESPRESSO MACHINE 0-1 CWF� R 3/4" ESPRESSO MACHINE PUMP HUB DRAIN � 3/4" CWF AIR GAP PER CODE. MINIMUM 1" 1 5/8" WIRE REINFORCED DRAIN HOSE TO INDIRECT PIPE RISER (TYP. 2) 2" ABS DWV INDIRECT WASTE PIPE TO FLOOR SINK SLOPE HORIZONTAL AT 1/4" PER FOOT. HOLD PIPING 'TIGHT TO BACK WALL (TYP.) BACK FLOW PREVENTION DEVICE WHERE REQUIRED. VERIFY TYPE AND LOCATION WITH LOCAL JURISDICTION. •. 3/4"CWF 3/4" 1 /2"HW SEE ESP SINK DETAIL. -1 /2"Cw -- ---- BALL VALVE 0 STUB UP (TYP.) FLOOR SINK ESPRESSO MACHINE PIPING CONNECTION DETAIL NTS * IF ONLY ONE ESPRESSO IS SHOWN IN PLAN VIEW AT THE FRONT LINE, F&I PIPE TO FUTURE LOCATION & BALL VALVE. DETAIL NOTES 1. THIS DETAIL IS SCHEMATIC ONLY. SEE THE PLAN DRAWINGS. 2. ALL WATER HOSES SHALL BE THE MINIMUM LENGTH NEEDED AND SUPPORTED AS NEEDED TO AVOID STRESSING CONNECTIONS AND COILING EXCESSIVE HOSE. ROUTE TO AVOID KINKING AND ALLOW SPACE FOR UNDER COUNTER REFRIGERATOR AND ACCESS TO EQUIPMENT AND VALVES. 3. ALL PIPING SHALL BE HELD TIGHT TO WALLS, SLOPED WHERE NEEDED AND ROUTED TO ALLOW ACCESS TO EQUIPMENT AND VALVES. 4. ROUTE HORIZONTAL PIPING A MINIMUM OF 6" ABOVE FLOOR. 5. COORDINATE LOCATION AND ELEVATION OF ALL EQUIPMENT WITH OTHER TRADES. ORIENT PUMP AS NEEDED TO ALLOW MAINTENANCE. "FILTERED" = FW A -SYSTEM - CWF B-SYSTEM CWN C-SYSTEM - RO REFER TO SUPPLY PIPING DIAGRAM "F 001 REVIEWED FOR ODE COMPLIANCE APPROVED MAY 082014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 01 2014 PERMIT CENTER „rr;.;; i.;:rg`. Ca2011 Starbucks Coffee Company Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318-1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. REPASCH ENOINEE IN0 LLC 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH:360-863-6677 FX:360-863-3565 rensch.engineering@comcast.net Revision Schedule Rev Date By Description Project Name: PARKWAY SUPERCENTER Project Address: 17480 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: 3267 04447-027 2-14-2014 Christy Monge Bill Bennecker Dave Carlson Chris Rensch Sheet Title: Plumbing Details Scale: Sheet Number: P-5001