HomeMy WebLinkAboutPermit PG14-0080 - LULULEMON - NEW RESTROOM, BREAKROOM SINK AND WATER FOUNTAINLULULEMON
21 S OUTh CENTER MALL
PG1 4-0080
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
Parcel No: 9202470130
PLUMBING/GAS PIPING PERMIT
Permit Number: PG14-0080
Address: 21 SOUTHCENTER MALL Issue Date: 8/6/2014
Permit Expires On: 2/2/2015
Project Name: LULULEMON
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD, CA,
92013
Contact Person:
Name: MELANI DANNENBERG Phone: (310) 263-3587
Address: 20521 EARL ST , TORRANCE, CA, 90503
Contractor:
Name: BOND PLUMBING Phone: (425) 672-8281
Address: 1630 215 ST SW , LYNNWOOD, WA,
98036
License No: BONDP**098K1 Expiration Date: 4/23/2015
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALL FIXTURES, PIPING, SANITARY AND VENTS FOR NEW RESTROOM, BREAK ROOM SINK AND WATER
FOUNTAIN.
Valuation of Work: $15,000.00
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Fees Collected: $217.76
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
Permit Center Authorized Signature:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Date: 6d4W/C(
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
127')•11
Cu -gond
Signature:
Print Name:
Date: g..".‘ 24/
4-1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE :OCATA —
.
King Co Assessor's Tax No.: 1 !'/z.st1, ---o1
Site Address: 21 SOUTHCENTER Suite Number: 748 Floor: 1st
Tenant Name: LULULEMON
:;PROPERTY OWNER
Name: WESTFIELD, LLC
Address: 2800 SOUTHCENTER
City: SEATTLE State: WA
Zip: 98188
CONTACT1PERSON - person receiving all projecf'. 3 '
co_mmi nication "- a _
Name: MELANI DANNENBERG
Address: 20521 EARL ST
City: TORRANCE State: CA
Zip: 90503
Phone: (310) 263-3587 Fax: (775)
766-9742
Email: MDANNENBERG@MENEMSHASOLUTIO
New Tenant: ❑ Yes m..No
PI UMBI OONTRACTOR;INFORMATIUN
Company Name: T.B.D.
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of Project (contractor's bid price): $ 15,000
Scope of Work (please provide detailed information):
Install fixtures, piping, sanitary and vents for new restroom, break room sink and water fountain.
Building Use (per Int'l Building Code): MERCANTILE
Occupancy (per Int'I Building Code): 92
Utility Purveyor: Water: Sewer:
H:\ApplicationsWorzns-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
0
Dishwasher, domestic with
independent drain
0
Shower, single head trap
0
Sinks
1
Rain water system — per
drain (inside building)
0
Grease interceptor for
commercial kitchen (>750
gallon capacity)
0
Each additional medical
gas inlets/outlets greater
than 5
0
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
0
Fixture Type
Qty
Bidet
0
Drinking fountain or water
cooler (per head)
1
Lavatory
1
Urinal
Water heater and/or vent
1
Repair or alteration of
water piping and/or water
treatment equipment
0
Backflow protective device
other than atmospheric-
type vacuum breakers 2
inch (51 mm) diameter or
smaller
0
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
0
Fixture Type
Qty
Clothes washer,
domestic
0
Food -waste grinder,
commercial
0
Wash fountain
0
Water closet
1
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
0
Repair or alteration of
drainage or vent piping
0
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
0
Gas piping outlets
0
Fixture Type
Qty
Dental unit, cuspidor
0
Floor drain
1
Receptor, indirect waste
0
Building sewer and each
trailer park sewer
0
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
0
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
0
Each lawn sprinkler
system on any one meter
including backflow
protection devices
0
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING MTER OR AU IORIZFD AGENT:
Signature: a�,�,
Print Name: MELANI DANNENBERG
Mailing Address: 20521 EARL ST
Day Telephone:
TORRANCE
City
Date: 4 Jr f j3l iq
(310) 263-3587
CA 90503
State Zip
H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8.9-] ].docx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY ( PAID
PermitTRAE
40.88
PG14-0080 Address: 21 SOUTHCENTER MALL Apn: 9202470130
II
O.
PLUMBING
$32.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
TECHNOLOGY. FEE
$8.38
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2790
R000.322.900.04.00
0.00
$8.38
$40.88
Date Paid: Wednesday, August 06, 2014
Paid By: BOND PLUMBING
Pay Method: CHECK 11224
Printed: Wednesday, August 06, 2014 10:35 AM 1 of 1
CRWSYSTEMS
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY PAID
$3,237.04
D14-0150 Address: 21 SOUTHCENTER MALL
Apn: 9202470130 $2,092.04
DEVELOPMENT
$2,092.04
PLAN CHECK FEE
R000.345.830.00.00
$2,087.54
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
EL14-0465 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $842.94
ELECTRICAL
$802.80
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
$802.80
TECHNOLOGY FEE
$40.14
TECHNOLOGY FEE
R000.322.900.04.00
$40.14
M14-0103 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $125.18
MECHANICAL
$125.18
PLAN CHECK FEE
R000.322.102.00.00
$125.18
PG14-0080 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $176.88
PLUMBING
$176.88
PLAN CHECK FEE
R000.322.103.00.00
$41.88
PERMIT FEE
TOTAL FEES PAID BY RECEIPT: R2124
R000.322.100.00.00
$135.00
$3,237.04
Date Paid: Wednesday, May 14, 2014
Paid By: MENEMSHA DEVELOPMENT GROUP
Pay Method: CHECK 013245
Printed: Wednesday, May 14, 2014 2:16 PM 1 of 1
SYSTEMS
46
INSPECTION RECORD
Retain a copy with permit ' ' 1 LI-0UU0
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451
Project: (_
L-0Lvt-&141Glei
Type of_Inspection:
C`1 ri3 AL. -
Address:
Date Called:
Special Instructions:
Date Wanted:
(7-2.O- (
4
`'1
Gnu:
P•m-
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
C' /Y> rt ( (--, nt10 J - / / f ; 6\ikl I
d
In ctor:
> i7
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection.
Date:
id
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project/ //
(,//_ /'-
Typ f)ns ection: �✓
Ad&es, /
D to Cailed:
.
Special Instructions:
(«f / -
90, T.7>tte
Date Wanted:
4 1
a.m
Requester:
e:jR/ 2 ;
Phone No:1
(,,/
Approved per applicable codes.
COMMENTS:
A
oval.
1i,
(5K TPC7
Inspector:
Date: /Lt.
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
pp jL-039c.
Project:
Type of Inspection:
.
Address:
.1LSa
n
4//
Date Cal d:--t_
LJ-Cc���
Special Instructions:
Date Wanted:
a.m.
Requester:
Phone No:
1:21!...%pproved per applicable codes. D Corrections required prior to approval.
COMMENTS:
Irispect:
Date
r
REINSPECTION FEE REQUI, ED. Prior to n ?tt inspection, fee must be
pad at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
\,.-I_,:�\At✓x kA--�'
TYpe� tini,03C ce.Project:
Address:
d- t SO tv- \ L.i ,,
Date Called:
Special Instructions:
Date Wanted:
{'„— 144
a.m.
' p.m.
Requester:
Phone No:
Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS: V
I\ - 6 ? -i13c. \
L-\ (��;�
f
Inspe` tor:
t \ r
REINSPECTION FEE REQUIRED. Priorlto next inspection, fee must be
°id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
PERMIT COORD COPS
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0080
PROJECT NAME: LULULEMON
DATE: 05/14/2014
SITE ADDRESS: 21 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
bc.14/ (I1
Building Division 1111
Public Works
Fire Prevention
Structural
Planning Division n
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 05/15/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
l e,(.li v\ ?GI
DUE DATE: 06/12/14
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
BOND PLUMBING
Page 1 of 2
Washington State Department of
, Labor & Industries
BOND PLUMBING
Owner or tradesperson
BOND, CURTIS
Principals
BOND, CURTIS, OWNER
Doing business as
BOND PLUMBING
WA UBI No.
601 319 698
1630 215TH ST SW
LYNNWOOD, WA 98036
425-672-8281
SNOHOMISH County
Business type
Individual
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
PLUMBING
License no.
BONDP**098K1
Effective — expiration
05/21/1991— 04/23/2015
Bond
RLI INS CO
Bond account no.
SRS1008453
Received by L&I
04/22/2002
Insurance
Liberty Northwest Ins Corp
Policy no.
BKS54441885
Received by L&I
03/12/2014
Insurance history
Savings
No savings accounts during the previous 6 year period.
$6,000.00
Effective date
04/21/2002
Expiration date
Until Canceled
$1,000,000.00
Effective date
04/06/2011
Expiration date
04/06/2015
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601319698&LIC=BONDP**098K1&SAW= 08/06/2014
FILE COPY
Permit No, PCB I 0O
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Filet! Copy and coneys is aduacknowledged:
By.(7
Date:
City Of lbkwila
BUILDING DIVISION
PLUMBING WASTE AND VENT PLAN
PLUMBING DOMESTIC WATER PLAN
SCALE: 1/4" = 1'-0"
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
SEPARATE PERMIT
REQUIRED FOR:
echanical
Electrical
Plumbing
Oit Gas Piping
City of Tukwila
PULDMI,G DIVISION
VERIFY ALL CONDITIONS IN FIELD
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR, TO:
BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT
SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO
EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR
OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND
INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE
ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED
AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF
LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL
WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND
SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR
OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.
NOTE:
INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING PLUMBING SYSTEM IS BASED ON RECORD
DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY
ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND.
REVIEWED FOR
ADDITIONAL NOTES:
• FLOOR DRAINS SHALL HAVE TRAP PRIMERS.
• NO PVC PIPING ABOVE GRADE.
• NO PIPING IN DEMISING WALLS.
CODE COMPLIANCE
APPROVED
MAY 192014
PLUMBING GENERAL NOTES: City of I u ila
BUILDING : ISION
1 DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK.
REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT
MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS.
NOTIFY THE OWNER'S CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO
SUBMISSION OF BID..
2. FURNISH A CONSTRUCTION RECORD SET OF "AS -BUILT" DOCUMENTS TO THE OWNER'S
CONSTRUCTION MANAGER REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS OR
EQUIPMENT CONTRARY TO THE CONSTRUCTION DOCUMENTS PREPARED BY THE
ENGINEER -OF -RECORD AFTER FINAL INSPECTION OF INSTALLED PLUMBING SYSTEMS.
3. FURNISH TO THE OWNER'S CONSTRUCTION MANAGER A COPY OF INSPECTION REPORTS AND
APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS.
INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE REQUIREMENTS OF
AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL REQUIREMENTS OF THE LANDLORD.
5. PLANS AND
SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS.
6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE START OF
PROJECT.
7. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING
FIXTURES.
8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE ROUTING.
9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED.
10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE NECESSARY,
SHALL BE ROUTED ,AS HIGH. AS POSSIBLE AND TIGHT TO WALLS.
11. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS.
12. COORDINATE PIPING ,9NSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS,
ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED
ON PLANS. COORGINATE"'SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER,
STRUCTURAL CONTRACTOR`' AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED.
13. CLEAN FAUCET AER' TORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE
OWNER.
14. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES.
15. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROUTE PIPING OVER
ELECTRICAL PANELS.
16. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10' MINIMUM CLEARANCE
FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT.
17. INSULATE PIPING ROUTED IN EXTERIOR BUILDING WALLS WITH MINIMUM 2" BATT INSULATION TO
PREVENT FREEZING.
18. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE.
19. PROVIDE CHECK VALVES IN HOT AND COLD WATER SUPPLIES FOR MOP SINK FAUCETS
DOWNSTREAM OF SHUTOFF VALVES.
20. GENERAL CONTRACTOR SHALL ROD AND SCOPE WASTE LINE TO LANDLORD'S MAIN PRIOR TO
TURNOVER.
21. HARD 90 DEGREE TURNS WILL NOT BE ALLOWED ON WASTE LINES. TURNS MUST BE SWEEPING.
PLUMBING PLAN KEYNOTES: (OO ,O,OO )
RECEIVED
CITY OF TUKWILA
MAY 1.4 2014
PERMIT CENTER
1. CONNECT 4" WASTE LINE. TO EXISTING WASTE LINE. FIELD VERIFY EXACT LOCATION.
2. WATER FILTER, SEE PLUMBING FIXTURE SCHEDULE.
3. COORDINATE INSTALLATION OF WATER FEATURE. REFER TO SHEET A823 FOR MORE INFORMATION.
4. INSTALL WATER CLOSET. ROUGH -IN AND CONNECT 3/4" COLD WATER, 4" WASTE AND 2" VENT.
5. INSTALL LAVATORY. ROUGH -IN AND CONNECT 1/2" HOT WATER, 1/2" COLD WATER, 2" WASTE
AND 1-1/2" VENT.
6 INSTALL ELECTRIC WATER HEATER ABOVE MOP SINK. SET DISCHARGE TEMPERATURE TO 110'F.
7. INSTALL KITCHEN SINK. ROUGH -IN AND CONNECT 3/4" HOT WATER, 3/4" COLD WATER, 2" WASTE
AND 1-1/2" VENT.
8 INSTALL MOP SINK. ROUGH -IN AND CONNECT 3/4" HOT WATER, 3/4" COLD WATER, 3" WASTE
AND 2" VENT. PROVIDE TEMPERING MIXING VALVE (WATTS MMV-US, 3/4" CONNECTION) TO LIMIT
THE MAXIMUM HOT WATER TEMPERATURE TO 105'F.
9. CONNECT 1-1/2" COLD WATER LINE TO EXISTING COLD WATER LINE. FIELD VERIFY EXACT
LOCATION. PROVIDE WATER SUB -METER WITH REMOTE READER.
10. INSTALL FLOOR DRAIN. ROUGH -IN AND CONNECT 2" WASTE AND 1-1/2" VENT.
11. INSTALL TRAP PRIMER. ROUGH -IN AND CONNECT 1/2" COLD WATER.
Dos°
MEP Engineer of Record
Randall A. Nelson, P. E.
14817 West 95th Street
Lenexa, Kansas 66215
Phone 913 322 5150
DESCRIPTION
WASt
43448 9 ' '
EXPIRES 9/21/2015
PLUM3ING FLOO PLAN
LULULEO\ ATHLETICA
CO\STUCTIO\ STAN3ADS
21 sourHCENree, SUITE gas
TUKWILA, WA 98188
ISSUE FOR SD 03/24/14
ISSUE FOR DD-LLL 04/15/14
ISSUE FOR DD-LLD 04/18/14
ISSUE FOR CD-LLL 05/01/14
ISSUE FOR CD -LLD 05/01/14
ISSUE FOR PERMIT xx/xx/xx
ISSUE FOR BID xx/xx/xx
Scale: AS INDICATED
Date: 3/7/14
Drawn By. DP/DB
Checked By CF
Job Number: 142.0115
Drawing:
FLU
V3I\G
ANNOTATION
0
SY
V
3OLS
PLUMBING PLAN NOTE CALLOUT
PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED
1 AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT
SCHEDULES
EQUIPMENT DESIGNATION (OWNER FURNISHED,
CONTRACTOR INSTALLED)
MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED
AND INSTALLED UNLESS NOTED OTHERWISE)
CONNECTION POINT OF NEW WORK TO EXISTING
DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER
LOWER NUMBER INDICATES SHEET NUMBER
SECTION CUT DESIGNATION
THIS IS A NOTE: MASTER
ABBREVIATIONS, ETC. ARE LSYMBOLS, ARENEC NECESSARILY USED ON THE DRAWINGS.
STANDARD MOUNTING HEIGHTS
PLUMBING
REFER TO THE ARCHITECTURAL DRAWINGS FOR
UNO, INSTALL PLUMBING FIXTURES WITH THE
WITH FINAL APPROVAL BY THE ARCHITECT.
ADA ACCESSIBLE DRINKING FOUNTAIN
ADA ACCESSIBLE LAVATORIES
ADA ACCESSIBLE SHOWER VALVES
ADA ACCESSIBLE TUB VALVES
ADA ACCESSIBLE URINALS
ADA ACCESSIBLE WATER CLOSET
ADA ACCESSIBLE WATER COOLER
ADULT STANDARD DRINKING FOUNTAIN
ADULT STANDARD WATER COOLER
CHILD STANDARD DRINKING FOUNTAIN
CHILD STANDARD WATER COOLER
CHILD URINAL
CLINIC SERVICE SINKS
JANITOR'S SINK FAUCET FITTINGS
HOSE BIBBS
ICE MAKER OUTLET BOXES
LAVATORY OR SINK
NON FREEZE HYDRANT
SHOWER HEADS
SHOWER VALVES
STANDARD URINALS
SURGEON'S SCRUB -UP SINKS
TUB VALVES
WASHING MACHINE OUTLET BOXES
WATER CLOSET
(AFF, AFG, UNLESS NOTED OTHERWISE)
PLUMBING FIXTURE MOUNTING HEIGHTS.
MOUNTING HEIGHTS AS LISTED BELOW
17" FLOOR TO RIM
34" FLOOR TO RIM
38" MINIMUM TO 48" MAXIMUM
FLOOR TO CENTERLINE
CENTER BETWEEN GRAB BAR
AND TUB RIM
17" FLOOR TO RIM
17" TO 19" FLOOR TO
TOP OF SEAT
35" FLOOR TO RIM
40" FLOOR TO RIM
30" FLOOR TO RIM
30" FLOOR TO RIM
14" FLOOR TO RIM
14" FLOOR TO RIM
30" FLOOR TO RIM
42" FLOOR TO CENTERLINE
36" AFF TO CENTERLINE
24" FLOOR TO CENTER OF BOX
31" FLOOR TO RIM
18" AFG TO CENTERLINE
6'-0 MEN & 5'-6" WOMEN
FLOOR TO CENTERLINE
48" MEN & 42" WOMEN FLOOR
TO CENTERLINE
22" FLOOR TO RIM
35" FLOOR TO FRONT RIM
32" FLOOR TO CENTELINE
42" FLOOR TO RIM
15" FLOOR TO RIM
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
BFF BELOW FINISHED FLOOR
BFG BELOW FINISHED GRADE
BOP BOTTOM OF PIPE
BOS BOTTOM OF STRUCTURE
BTU BRITISH THERMAL UNIT
CPVC CHLORINATED POLYVINYL
CHLORIDE
DN DOWN
DFU DRAINAGE FIXTURE UNIT
DS DOWNSPOUT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FFA
FFB
FF
FROM FLOOR ABOVE
FROM FLOOR BELOW
FINISHED FLOOR
FL FLOW LINE
FLA FULL LOAD AMPS
FLR FLOOR
GPM GALLONS PER MINUTE
HD HEAD, HUB DRAIN
IE INVERT ELEVATION
IN WC INCHES OF WATER COLUMN
JB JUNCTION BOX
J—BOX JUNCTION BOX
kW KILOWATT
MAU MAKE—UP AIR UNIT
MAX MAXIMUM
MBH 1000 BTU PER HOUR
MH
MIN
N/C
N/0
ORD
PDI
PVC
PRV
RD
RPM
RTU
SF
SP
SS
SEWER,
TDH
TFA
TFB
TYP
UL
INC.
UNO
UPS
v
VCP
VS
VTR
w/
W/0
WC
WS
WSFU
MANHOLE
MINIMUM
NORMALLY CLOSED
NORMALLY OPEN
OVERFLOW ROOF DRAIN
PLUMBING DRAINAGE INSTITUTE
POLYVINYL CHLORIDE
PRESSURE REDUCING VALVE
ROOF DRAIN
REVOLUTIONS PER MINUTE
ROOFTOP UNIT
SQUARE FEET, SUPPLY FAN
SUMP PUMP
STAINLESS STEEL, SANITARY
SOIL STACK
TOTAL DYNAMIC HEAD
TO FLOOR ABOVE
TO FLOOR BELOW
TYPICAL
UNDERWRITERS LABORATORIES,
UNLESS NOTED OTHERWISE
UNINTERRUPTIBLE POWER SUPPLY
VOLT(S)
VITRIFIED CLAY PIPE
VENT STACK
VENT THROUGH ROOF
WITH
WITHOUT
WATER COLUMN
WASTE STACK
WATER SUPPLY FIXTURE UNIT
PIPING
DOMESTIC COLD WATER (CW)
SCW SOFTENED COLD WATER (SCW)
DOMESTIC HOT WATER (HW)
DOMESTIC HOT WATER RECIRC. (HWR)
140' 140' DOMESTIC HOT WATER (140')
T TRAP PRIMER LINE (T)
S SOIL PIPING - ABOVE FLOOR (S)
S SOIL PIPING - BELOW FLOOR (S)
W WASTE PIPING - ABOVE FLOOR (W)
W WASTE PIPING - BELOW FLOOR (W)
GW GREASE WASTE - ABOVE FLOOR (GW)
GW GREASE WASTE - BELOW FLOOR (GW)
ST STORM DRAIN - ABOVE FLOOR (ST)
ST STORM DRAIN - BELOW FLOOR (ST)
OST OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)
VBG VENT BELOW GRADE (VBG)
VBF VENT BELOW FLOOR (VBF)
ID INDIRECT DRAIN (ID)
CDH CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH)
CD CONDENSATE DRAIN (CD)
ACD AUXILIARY CONDENSATE DRAIN (ACD)
SPD SUMP OR SEWAGE PUMP DISCHARGE (SPD)
G NATURAL GAS (G)
G NATURAL GAS ON ROOF (G)
-MPG MEDIUM PRESSURE NATURAL GAS (MPG)
MPG MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)
NPW NON POTABLE WATER (NPW)
LPG LIQUIFIED PETROLEUM GAS (LPG)
WS WATER SERVICE (WS)
FP FIRE PROTECTION (FP)
PD CONDENSATE PUMP DISCHARGE (PD)
EXISTING PIPING TO BE REMOVED
EXISTING PIPING TO REMAIN
V VENT PIPING (V)
SQUARE FLOOR DRAIN (FS), SIZE & TYPE
ROUND FLOOR DRAIN (FD), SIZE & TYPE
t0 ROOF DRAIN (RD), SIZE & TYPE
lr BALL VALVE
CONTROL VALVE
SHUTOFF VALVE
IV CHECK VALVE
BALANCING VALVE WITH PRESSURE PORTS
WATER METER
Iyi STRAINER
STRAINER WITH BLOWOFF
- RELIEF/SAFETY VALVE
D44 SOLENOID VALVE
PRESSURE REDUCING VALVE
D1 a GAS PRESSURE REGULATOR
THERMOSTATIC MIXING VALVE
PA PIPE ANCHOR
--oEJ EXPANSION JOINT
BACKFLOW PREVENTER
PRESSURE GAUGE
THERMOMETER
UNION
FLANGE CONNECTION
HOSE BIBB (HB)
NONFREEZE WALL HYDRANT (NW)
MANUAL / AUTOMATIC AIR VENT OR VACUUM
RELIEF VALVE
CLEANOUT
CAP
D-II WALL CLEANOUT (WCO)
® FLOOR CLEANOUT (FCO)
o❑ EXTERIOR CLEANOUT (ECO)
o ELBOW UP
-moo ELBOW DOWN
TEE UP
TEE DOWN
ELBOW UP WITH SHUT-OFF VALVE (SOV)
'2 ELBOW DOWN WITH SHUT-OFF VALVE (SOV)
TEE UP WITH SHUT-OFF VALVE (SOV)
TEE DOWN WITH SHUT-OFF VALVE (SOV)
WATER HAMMER ARRESTER (WHA)
WITH PDI SIZES, (A, B, C, D, & E)
RECIRCULATION PUMP
Do P-TRAP
iii GAS COCK
e TRAP PRIMER
eo TRAP PRIMER WITH DISTRIBUTION UNIT
EXISTING PIPING TO BE REMOVED
EXISTING PIPING TO REMAIN
1
"A"
WATER FEATURE
HANGERS
INSTALLED
EACH SIDE OF
EXP. TANK
FOR SUPPORT
BALL VALVE
BY P.C. (TYP.)
3/4" RUN FULL SIZE
TO FLOOR DRAIN. - -
DRAIN VALVE BY P.C.
PLATFORM ABOVE MOP SINK
RE: ARCHITECTURAL DRAWINGS
WASTE AND VENT RISER DIAGRAM
NTS
BY P.C.
VACUUM BREAKER
AMTROL ST-5
THERMAL
EXPANSION
ABSORBER
INSULATE ALL PIPING
IN ACCORDANCE WITH
CW / SPECIFICATIONS.
HW—H
6"
WH-1
®WATER HEATER DETAIL
3/4"T & P RELIEF
VALVE BY P.C.
— WATER HEATER SEE
PLUMBING FIXTURE
SCHEDULE FOR
ADDITIONAL INFO.
2" WIDE, 20 GA. SHEET
METAL BAND, SECURE
TO WALL FOR SEISMIC
BRACING WHERE
REQUIRED BY CODE.
(BY P.C.)
GALV. DRIP PAN
BY P.C.
SEPARATE
3/4" DRAINS TO
TO MOP SINK
PAINTED TO MATCH
COVER PLATE WITH
SCREW
WATER FEATURE
MAY EXTEND AS A
WASTE OR VENT
WALL
PLUGGED TEE WITH
CLEAN OUT
WALL CLEANOUT DETAIL
NTS
FLOOR
-1 /2"CW
KS-1
DOMESTIC WATER RISER DIAGRAM
NTS
12" MINIMUM
TO HORIZONTAL
RUN IN PIPE
CONNECT TO
FLOOR DRAIN
(TYP.)
1 /2 COLD WATER
SUPPLY CONNECTION
SOLENOID
VALVE
METAL CABINET
AUTOMATIC
TRAP PRIMER
1/2"
TRAP WATER LEVEL
REVIEWELJ r )R
CODE COMPLIANCE
APPROVED
MAY 19 2014
City of Tukwila
BUILDING DIVISION
FLOOR DRAIN
I
t
TRAP PRIMER DETAIL
NTS
RECEIVED
CITY OF TUKWILA
MAY 1 4 2014
PERMIT CENTER
MEP Engineer of Record
Randall A. Nelson, P. E.
14817 West 95th Street
Lenexa, Kansas 66215
Phone 913 322 5150
r
i
,,
U
DESCRIPTION
' 4
r+
Ii)
-14
DATE
-I
z
A.
41P
'1111. 43448 , ''"
o '(. SI 'e'
1.
EXPIRES 9/21/2015
LUMBING RISERS AND DETAILS
LULULEVON ATHLETICA
CO\STUCTO\ STAN3A3S
21 SOUTHCENTER, SUITE I48
TUKWILA, WA 98188
LJ_
ISSUE FOR SD 03/24/14
ISSUE FOR DD—LLL 04/15/14
ISSUE FOR DD—LLD 04/18/14
ISSUE FOR CD—LLL 05/01/14
ISSUE FOR CD —LLD 05/01/14
ISSUE FOR PERMIT xx/xx/xx
ISSUE FOR BID xx/xx/xx
Scale: AS INDICATED
Date: 3/7/14
Drawn By. DP/DB
Checked By: CF
Job Number: 1 42.0115
Drawing:
PLUMBING SPECIFICATIONS: SECTION 15200
A. SCOPE OF WORK
THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS,
TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE
FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING
SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY
JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY
SCHEDULE FOR EXACT RESPONSIBILITIES)
A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS.
B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION.
C. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED.
D. TESTS AND ADJUSTMENTS.
BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL,
MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND
INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH
OTHER CONTRACTORS TO AVOID INTERFERENCE'S AND CONFRONTATIONS.
RELOCATION OF EXISTING WATER, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN
CRITERIA MUST BE INCLUDED IN BID PROPOSAL.
ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL
CODES AND THE LANDLORD'S REQUIREMENTS. VERIFY LOCAL ADA AND WATER -SAVING DEVICE 'CODE
REQUIREMENTS PRIOR TO CONSTRUCTION.
CONTRACTOR SHALL SUBMIT A REPRODUCIBLE COPY OF THE "AS -BUILT" DRAWING TO THE LANDLORD
AND TO THE OWNER FOR THEIR RECORDS.
B. PLUMBING EQUIPMENT
PROVIDE NEW PLUMBING EQUIPMENT AS SHOWN ON THE DRAWING AND SPECIFIED IN THE PLUMBING
FIXTURE SCHEDULE.
WHERE EXISTING PLUMBING FIXTURES ARE TO BE REUSED, REPLACE BALL COCK VALVE SEALS, LEAVE
IN PROPER WORKING ORDER.
C. GENERAL PIPING REQUIREMENTS
1. GENERALLY, SANITARY AND POTABLE WATER CONNECTIONS WILL BE MADE AT TOILET ROOM AND
OTHER PLUMBING FIXTURES SHOWN ON PLANS. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO
SUBMITTING BID AND NOTIFY THE TENANT'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS
SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE
OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS:
A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE.
B. TEST WATER PRESSURE TO INSURE MINIMUM OF 50 PSI.
2. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING
AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM
SPAN OF 5 FEET.
3. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE
PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS.
4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S
CRITERIA.
5. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT'S DEMISED
PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO
OTHER TENANTS AND/OR TO THE BUILDING. FAILURE TO DO SO SHALL BE AT RISK AND SOLE
EXPENSE OF THE CONTRACTOR.
D. PIPING
SANITARY PIPING - NO PVC ALLOWED
A. WASTE AND DRAIN PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. ALL VENT PIPING
SHALL BE CAST IRON. NO -HUB JOINTS: BELOW FLOOR SLAB - COMPRESSION TYPE PLATIC
SEAL (HUB AND SPIGOT). ABOVE FLOOR SLAB - NEOPRENE SEALING SLEEVE WITH STAINLESS
STEEL SHIELD AND CLAMP WITH APPROVED NEOPRENE - BASED LUBRICANT, (HUBLESS).
B. PITCH WASTE LINES 2" AND SMALLER NOT LESS THAN 1/4" PER FOOT. PITCH LARGER MAINS
NOT LESS THAN 1/8" PER FOOT.
C. INSTALL A CLEANOUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT
INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY AT
INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY
LOCAL CODE. CLEAN OUTS SHALL ONLY BE INSTALLED IN NON-PUBLIC AREAS, UNLESS GIVEN
EXPRESSED WRITTEN PERMISSION BY TENANT'S CONSTRUCTION MANAGER. WHEN GIVEN PERMISSION
TO INSTALL IN PUBLIC AREAS, THE CLEANOUTS SHALL HAVE STAINLESS STEEL WALL COVERS AND
BRASS FLOOR COVERS (FLUSH WITH FINISHED FLOOR) PROVIDED BY THE CONTRACTOR. PROVIDE
COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN -OUT LOCATIONS SHALL
BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER.
D. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE.
INSULATION TO BE AS SPECIFIED FOR WATER PIPING, SEE #5.
E. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG
"ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAV GUARD" INSULATION KIT.
2. CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER TUBE WITH 95-5 TIN -ANTIMONY SOLDERED
JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS.
3. POTABLE WATER PIPING:
A. BELOW GRADE: TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND
SMALLER. BRAZE ALL JOINTS.
B. ABOVE GRADE: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5
TIN -ANTIMONY SOLDER.
C. INSTALL SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER
HAMMER.
D. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES
IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY.
E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES
REQUIREMENTS IF APPLICABLE. REFER TO PLANS FOR FOR ADDITIONAL INFORMATION.
F. SECURE PIPE AT ANGLE STOPS.
G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM
HITTING FRAME WHEN IN OPERATION.
4. GAS PIPING - NOT APPLICABLE
5. INSULATION
A. INSULATE ALL WATER AND INTERIOR CONDENSATE PIPING WITH 1" THICK (K=0.23 0 75
F) SNAP -ON FIBERGLASS PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL
CODES AND UL FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATINGS OF 50.
APPROVED MANUFACTURER: MANVILLE MICRO-LOK.
6. TEST & STERILIZATION
A. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS:
B. TEST POTABLE WATER PIPING AND CONDENSATE PIPING AT 125 PSIG FOR SIX HOURS.
C. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. ALL JOINTS
SHALL BE GAS AND WATER TIGHT.
D. STERILIZE POTABLE HOT & COLD WATER LINES UPON COMPLETION OF SYSTEM. STERILIZE WATER
SYSTEM IN ACCORDANCE WITH LOCAL CODES.
FIELD VERIFY ALL CO
\DITION
S
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD
OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND
MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS.
THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR
INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE
DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE
FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST.
BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL
INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING
CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT,
ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.
PLUV311\G FIXTURE SCHEDULE
MARK
CONNECTIONS
MANUFACTURER/
MODEL NUMBER
HW
CW
V
W
WC-1
WATER CLOSET
(ADA)
ELONGATED COMBINATION TOILET, 12" ROUGH -IN, POLISHED
CHROME TRIP LEVER, VITREOUS CHINA, 1.6 GPF, EQUIPPED
WITH CLASS 5 FLUSHING SYSTEM, 16-1/2" RIM HEIGHT,
ADA COMPLIANT. INSTALL WITH TRIP LEVERS ON THE WIDE
SIDE OF THE STALL.
--
3/4"
2"
4"
STANDARD
KOHLER/K-3589
TANK/BOWL-COMBO
SEAT
HEAVY DUTY, ELONGATED, OPEN FRONT LESS COVER, SELF
SUSTAINING CHECK HINGE.
OLSONITE/95SSC
SUPPLIES
1/2" CHROME PLATED BRASS TUBING WITH BALL VALVE
ANGLE STOPS.
W -
$IE____17t241'HROME
CLOSET
(ADA)
ELONGATED COMBINATION TOILET, 12" ROUGH -IN, POLISHED
TRIP LEVER, VITREOUS CHINA, 1.28 GPF, 16-1/2"
RIM HEIGHT, LIANT. INSTALL WITH TRIP LEVERS
ON THE WIDE SIDE OF TH
--
3/4" .
2"
4"
CALIFORN
AN STANDARD
CADET 3 FLOWISE
TANK/BOWL-COMBO
SEAT
HEAVY DUTY, ELONGATED, OPE SS COVER, SELF
SUSTAINING CH
OLSONITE/95SSC
PLATED BRASS TUBING WITH BALL VALVE
ANGLE STOPS.
L-1
LAVATORY/ADA
"LUCERNE" WALL -HUNG LAVATORY, VITREOUS CHINA, FRONT
OVERFLOW, D-SHAPED BOWL, SELF -DRAINING DECK,
FAUCET LEDGE, FAUCET HOLES ON 4" CENTERS
1/2''
1/2''
1-1/2"
2"
AMERICAN STANDARD
0355.012
FAUCET
"AQUASENSE" HARDWIRED ELECTRONIC SENSOR FAUCET,
INTEGRAL FOUR INCH COVER PLATE, INFRARED
CONVERGENCE -TYPE PROXIMITY SENSOR LOCATED IN THE
CHROME PLATED CAST BRASS SPOUT, IN -LINE FILTER, 0.5
GPM VANDAL RESISTANT AERATOR, THERMOSTATIC MIXING
VALVE FOR SINGLE FAUCETS, INCLUDES FOUR 'AA' BATTERIES
TO PROVIDE BATTERY BACKUP POWER TO THE FAUCET DURING
POWER OUTAGES, SENSOR RANGE IS FACTORY SET FOR
OPTIMUM PERFORMANCE
ZURN
Z6915-HW6-CWB-F-TMV-1
SUPPLIES
3/8" CHROME PLATED ANGLED STOP WITH WHEEL HANDLE,
3/8" CHROME PLATED FLEXIBLE BRASS RISER, INSULATE
ALL EXPOSED WATER LINES AND VALVES
WASTE
GRID DRAIN, 4-1/2" OFFSET FOR WHEELCHAIR LAVATORY,
1-1/4" TAILPIECE, 1-1/4" 17 GAUGE CHROME PLATED
ADJUSTABLE BRASS P-TRAP WITH CLEANOUT PLUG RUN
PARALLEL AND AS TIGHT TO WALL AS POSSIBLE, 1-1/4"
CHROME PLATED BRASS WASTE TO WALL
AMERICAN STANDARD
7723.018
CARRIER
LAVATORY SUPPORT SYSTEM WITH TOP SUPPORT PLATE,
DURA-COATED RECTANGULAR STEEL UPRIGHTS WITH WELDED
FEET, ADJUSTABLE SUPPORT PLATE, AND MOUNTING
FASTENERS
ZURN/Z-1224
PROTECTIVE
PIPE COVER
ONE P-TRAP COVER, TWO ANGLE VALVES AND SUPPLY
COVERS, ONE 5" OFFSET TAILPIECE WHEELCHAIR STRAINER
COVER
TRUEBRO/103 E-Z
MOUNTING
HEIGHT
33 INCHES FLOOR TO RIM
KS-1
SINK
"LUSTERTONE" SINGLE BOWL, SEAMLESSLY FORMED OF #18
GAUGE, TYPE 304 (18-8) NICKEL BEARING STAINLESS
STEEL, SELF -RIMMING, FULLY UNDERCOATED UNDERSIDE TO
DAMPEN SOUND AND PREVENT CONDENSATION, 6" BOWL
DEPTH, 17"X16" OVERALL DIMENSIONS, 3 HOLES ON 4"
CENTERS
3/4" '
3/4"
,.
1-1/2"
2"
ELKAY/LRAD1716
FAUCET
DUAL HANDLE TOP MOUNT MIXING FAUCET, GOOSENECK
SWING SPOUT, HEAVY CHROME PLATE, REMOVABLE
CARTRIDGES, 1/2" I.P. CONNECTIONS, 4" BLADE HANDLES.
PROVIDE WITH 1.5GPM AERATOR.
ELKAY/LKD2432BH
SUPPLIES
1/2" CHROME PLATED ANGLE STOPS WITH LOOSE KEY
HANDLE, 1/2" CHROME PLATED FLEXIBLE BRASS RISER
WASTE
STANDARD DUO STRAINER, FITS 3 1/2" OPENING (4-1/2"
TOP DIAMETER), ONE PIECE STAINLESS CONICAL STRAINER
BASKET WITH NEOPRENE STOPPER, CHROME PLATED BRASS
TAILPIECE, 1-1/2" 17 GAUGE CHROME PLATED
ADJUSTABLE P-TRAP WITH CLEANOUT PLUG, 1 1/2"
CHROME PLATED BRASS WASTE TO WALL
ELKAY/LK-35
TP-1
TRAP PRIMER
MACHINED OF CORROSION RESISTANT BRASS CONTAINS NO
SPRINGS OR DIAPHRAGMS, INLET 1/2" MALE NPT, OUTLET
1/2" FEMALE NPT. PRESSURE ACTIVATED PRIMER DELIVERS
POTABLE WATER ACROSS AN AIR GAP FUNNEL THEN THROUGH
THE DISTRIBUTION UNIT WHEN IT SENSES A PRESSURE DROP
OF 5 TO 10 P.S.I.G.
--
1/2"
--
--
PRECISION PLUMBING PRODUCTS
INC. / P2-500
MOUNTING
HEIGHT
MINIMUM MOUNTING HEIGHT OF 12" ABOVE FINISHED FLOOR
WHEN FLOOR DRAIN SERVED IS 20'-0" OR LESS
DEVELOPED LENGTH FROM UNIT, MOUNT AN ADDITIONAL 12"
HIGHER FOR EACH ADDITIONAL 20"-0" OF LENGTH
SUPPLIES
DISTRIBUTION UNIT DU-2 FOR 1 OR 2 TRAPS, DU-3 FOR
3 TRAPS, OR DU-4 FOR 4 TRAPS, TO SUPPLY MORE THAN
FOUR TRAPS ADD DISTRIBUTION UNIT PAIRS UP TO 8
DRAINS, PROVIDE AG-500 AIR GAP CONNECTION.
FD-1
FLOOR DRAIN
COATED CAST IRON FLOOR DRAIN, TWO-PIECE BODY,
DOUBLE DRAINAGE FLANGE, INVERTIBLE NON -PUNCTURING
FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET INSIDE
CAULK CONNECTION, ADJUSTABLE ROUND SUPER-FLO
STRAINER, FLASHING CLAMP WITH 20"x24" 4 LB. LEAD
FLASHING FOR FLOOR DRAINS INSTALLED ABOVE SLAB ON
GRADE, 1/2" TRAP PRIMER CONNECTION.
--
--
1-1/2"
2"
ZURN/Z-415S-P
ZURN/TYPE 5
STRAINER
6" x 6" SQUARE NICKEL BRONZE FINISH
WASTE
CAST IRON P-TRAP UNDER FLOOR
WCO
_
WALL CLEANOUT
COATED CAST IRON CLEANOUT TEE, HUB AND SPIGOT
CONNECTION, BRONZE PLUG.
--
--
--
SEE
PLANS
ZURN/Z1468
FCO
OUT
ZURN MODEL #ZB-1400 DURA-COATED CAST IRON BODY,
"LE - ABLE FLOOR CLEANOUT, INSIDE CAULK
CONNECTION WITH GAS AND S TAPERED
THREAD INTERNAL PLUG ADJUSTABL
SCORIATED OP, POLISHED BRONZE
, INSTALL FLUSH WITH FINISHED FLOOR.
--
--
--
--
_ 0
MS-1
MOP SINK
MOLDED STONE, 2" CHROME STRAINER, WITH PAIL HOOK,
HOSE THREAD, VACUUM BREAKER, WALL SUPPORTS,
SUPPLIES WITH TEE OPS, P-TRAP, RIM GUARD
3/4"
3/4"
2"
3"
FIAT/MODEL MSB-2424
FAUCET
SERVICE SINK FAUCET
--
--
--
--
FIAT/MODEL 830AA
WF-1
REMOTE WATER
FILTER
INLINE POTABLE WATER FILTRATION SYSTEM. INSTALL WATER
FILTER PER MANUFACTURER'S RECOMMENDATIONS. IF
SUPPLIED WATER PRESSURE EXCEEDS 125 PSI, PROVIDE
FILTER WITH PRESSURE LIMITING VALVE.
--
3/4"
--
--
AQUA -PURE
AP200 SYSTEM
WITH AP217 FILTER
SH-1
S
ADA ACCESSIBLE
PISTON TYPE PRESSURE BALANCING MIXING VALVE WITH
MEETING ASSE 101.6P, SINGLE BLADE LEVER
HANDLE, ADJUSTA P SCREW SET AT 110F,
INTEGRAL SERVICE STOPS, "TEMPTR RE
BALANCING MIXING VALVE, "CLEAR-FLO"
ARM AND FLANGE SHOWER WITH FLEXIBLE
M -LINE VACUUM BREAKER, WALL
CONNECTION AND FLANGE, AND 30" SLIDE BAR.
3/4"
3/4"
1-1/2"
2"
S
5-500-B30-V
ELECTS I C WATER
HEATE
MARK
LOCATION
KW
GA L HRC 100'
/
DEGREE RISE;
ELECTRICAL
STORAGE CAP
MANUFACTURER
REMARKS
VOLTS
PHASE
EWH-1
PLATFORM
2.5
10
120
SINGLE
6 GALLONS
A.O. SMITH
MODEL NO. DEL-6
EXPANSIO\
TAB\
'S
MARK
LOCATION
SERVES
CAPACITY j
(GALLONS)
WORKING
PRESS
(PSI)
SIZE (APPROX)
MANUFACTURER
REMARKS
ET-1
PLATFORM
DOM. HW
0.9
150
12-5 8"0x8"
/
AMTROL
MODEL ST-5*
*CONTRACTOR SHALL ADJUST PRE -CHARGE OF
TO INSTALLATION.
EXPANSION TANK TO EQUAL INCOMING WATER PRESSURE PRIOR
REV CO P FOR
CODE COMPLIANCE
APPROVED
MA(192014
City of Tukwila
BUILDING DIVISION
FGIoo9
RECEIVED
CITY OF TUKWILA
MAY 142014
PERMIT CENTER
MEP Engineer of Record
Randall A. Nelson, P. E.
14817 West 95th Street
Lenexa, Kansas 66215
Phone 913 322 5.150
J
N
i
V
DESCRIPTION
M
0
DATE
-4
zz
o
WA ,,
s,:,,,,;4:48 d':
S 1Z
EXPIRES 9/21/2015
'LUMBING SCHEDULES
LULULEVO\ ATHLETICA
CO\STUCTIO\ STA\DADS
21 SOUTHCENTER, SUITE 748
TUKWILA, WA 98188
ISSUE FOR SD 03/24/14
ISSUE FOR DD—LLL 04/15/14
ISSUE FOR DD—LLD 04/18/14
ISSUE FOR CD—LLL- 05/01/14
ISSUE FOR CD —LLD 05/01/14
ISSUE FOR PERMIT xx/xx/xx
ISSUE FOR BID xx/xx/xx
Scale: AS INDICATED
Date: 3/7/14
Drawn By. DP/DB
Checked By. CF
Job Number: 142 0115
Drawing: