Loading...
HomeMy WebLinkAboutPermit PG14-0080 - LULULEMON - NEW RESTROOM, BREAKROOM SINK AND WATER FOUNTAINLULULEMON 21 S OUTh CENTER MALL PG1 4-0080 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 9202470130 PLUMBING/GAS PIPING PERMIT Permit Number: PG14-0080 Address: 21 SOUTHCENTER MALL Issue Date: 8/6/2014 Permit Expires On: 2/2/2015 Project Name: LULULEMON Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, CA, 92013 Contact Person: Name: MELANI DANNENBERG Phone: (310) 263-3587 Address: 20521 EARL ST , TORRANCE, CA, 90503 Contractor: Name: BOND PLUMBING Phone: (425) 672-8281 Address: 1630 215 ST SW , LYNNWOOD, WA, 98036 License No: BONDP**098K1 Expiration Date: 4/23/2015 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL FIXTURES, PIPING, SANITARY AND VENTS FOR NEW RESTROOM, BREAK ROOM SINK AND WATER FOUNTAIN. Valuation of Work: $15,000.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $217.76 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Date: 6d4W/C( I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. 127')•11 Cu -gond Signature: Print Name: Date: g..".‘ 24/ 4-1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE :OCATA — . King Co Assessor's Tax No.: 1 !'/z.st1, ---o1 Site Address: 21 SOUTHCENTER Suite Number: 748 Floor: 1st Tenant Name: LULULEMON :;PROPERTY OWNER Name: WESTFIELD, LLC Address: 2800 SOUTHCENTER City: SEATTLE State: WA Zip: 98188 CONTACT1PERSON - person receiving all projecf'. 3 ' co_mmi nication "- a _ Name: MELANI DANNENBERG Address: 20521 EARL ST City: TORRANCE State: CA Zip: 90503 Phone: (310) 263-3587 Fax: (775) 766-9742 Email: MDANNENBERG@MENEMSHASOLUTIO New Tenant: ❑ Yes m..No PI UMBI OONTRACTOR;INFORMATIUN Company Name: T.B.D. Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 15,000 Scope of Work (please provide detailed information): Install fixtures, piping, sanitary and vents for new restroom, break room sink and water fountain. Building Use (per Int'l Building Code): MERCANTILE Occupancy (per Int'I Building Code): 92 Utility Purveyor: Water: Sewer: H:\ApplicationsWorzns-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower 0 Dishwasher, domestic with independent drain 0 Shower, single head trap 0 Sinks 1 Rain water system — per drain (inside building) 0 Grease interceptor for commercial kitchen (>750 gallon capacity) 0 Each additional medical gas inlets/outlets greater than 5 0 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) 0 Fixture Type Qty Bidet 0 Drinking fountain or water cooler (per head) 1 Lavatory 1 Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment 0 Backflow protective device other than atmospheric- type vacuum breakers 2 inch (51 mm) diameter or smaller 0 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 0 Fixture Type Qty Clothes washer, domestic 0 Food -waste grinder, commercial 0 Wash fountain 0 Water closet 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of drainage or vent piping 0 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter 0 Gas piping outlets 0 Fixture Type Qty Dental unit, cuspidor 0 Floor drain 1 Receptor, indirect waste 0 Building sewer and each trailer park sewer 0 Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity 0 Medical gas piping system serving 1-5 inlets/outlets for a specific gas 0 Each lawn sprinkler system on any one meter including backflow protection devices 0 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING MTER OR AU IORIZFD AGENT: Signature: a�,�, Print Name: MELANI DANNENBERG Mailing Address: 20521 EARL ST Day Telephone: TORRANCE City Date: 4 Jr f j3l iq (310) 263-3587 CA 90503 State Zip H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8.9-] ].docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS Cash Register Receipt City of Tukwila ACCOUNT QUANTITY ( PAID PermitTRAE 40.88 PG14-0080 Address: 21 SOUTHCENTER MALL Apn: 9202470130 II O. PLUMBING $32.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 TECHNOLOGY. FEE $8.38 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2790 R000.322.900.04.00 0.00 $8.38 $40.88 Date Paid: Wednesday, August 06, 2014 Paid By: BOND PLUMBING Pay Method: CHECK 11224 Printed: Wednesday, August 06, 2014 10:35 AM 1 of 1 CRWSYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $3,237.04 D14-0150 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $2,092.04 DEVELOPMENT $2,092.04 PLAN CHECK FEE R000.345.830.00.00 $2,087.54 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 EL14-0465 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $842.94 ELECTRICAL $802.80 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $802.80 TECHNOLOGY FEE $40.14 TECHNOLOGY FEE R000.322.900.04.00 $40.14 M14-0103 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $125.18 MECHANICAL $125.18 PLAN CHECK FEE R000.322.102.00.00 $125.18 PG14-0080 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $176.88 PLUMBING $176.88 PLAN CHECK FEE R000.322.103.00.00 $41.88 PERMIT FEE TOTAL FEES PAID BY RECEIPT: R2124 R000.322.100.00.00 $135.00 $3,237.04 Date Paid: Wednesday, May 14, 2014 Paid By: MENEMSHA DEVELOPMENT GROUP Pay Method: CHECK 013245 Printed: Wednesday, May 14, 2014 2:16 PM 1 of 1 SYSTEMS 46 INSPECTION RECORD Retain a copy with permit ' ' 1 LI-0UU0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: (_ L-0Lvt-&141Glei Type of_Inspection: C`1 ri3 AL. - Address: Date Called: Special Instructions: Date Wanted: (7-2.O- ( 4 `'1 Gnu: P•m- Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: C' /Y> rt ( (--, nt10 J - / / f ; 6\ikl I d In ctor: > i7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. Date: id INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project/ // (,//_ /'- Typ f)ns ection: �✓ Ad&es, / D to Cailed: . Special Instructions: («f / - 90, T.7>tte Date Wanted: 4 1 a.m Requester: e:jR/ 2 ; Phone No:1 (,,/ Approved per applicable codes. COMMENTS: A oval. 1i, (5K TPC7 Inspector: Date: /Lt. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 pp jL-039c. Project: Type of Inspection: . Address: .1LSa n 4// Date Cal d:--t_ LJ-Cc��� Special Instructions: Date Wanted: a.m. Requester: Phone No: 1:21!...%pproved per applicable codes. D Corrections required prior to approval. COMMENTS: Irispect: Date r REINSPECTION FEE REQUI, ED. Prior to n ?tt inspection, fee must be pad at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 \,.-I_,:�\At✓x kA--�' TYpe� tini,03C ce.Project: Address: d- t SO tv- \ L.i ,, Date Called: Special Instructions: Date Wanted: {'„— 144 a.m. ' p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: V I\ - 6 ? -i13c. \ L-\ (��;� f Inspe` tor: t \ r REINSPECTION FEE REQUIRED. Priorlto next inspection, fee must be °id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPS PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0080 PROJECT NAME: LULULEMON DATE: 05/14/2014 SITE ADDRESS: 21 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: bc.14/ (I1 Building Division 1111 Public Works Fire Prevention Structural Planning Division n Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: l e,(.li v\ ?GI DUE DATE: 06/12/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 BOND PLUMBING Page 1 of 2 Washington State Department of , Labor & Industries BOND PLUMBING Owner or tradesperson BOND, CURTIS Principals BOND, CURTIS, OWNER Doing business as BOND PLUMBING WA UBI No. 601 319 698 1630 215TH ST SW LYNNWOOD, WA 98036 425-672-8281 SNOHOMISH County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. BONDP**098K1 Effective — expiration 05/21/1991— 04/23/2015 Bond RLI INS CO Bond account no. SRS1008453 Received by L&I 04/22/2002 Insurance Liberty Northwest Ins Corp Policy no. BKS54441885 Received by L&I 03/12/2014 Insurance history Savings No savings accounts during the previous 6 year period. $6,000.00 Effective date 04/21/2002 Expiration date Until Canceled $1,000,000.00 Effective date 04/06/2011 Expiration date 04/06/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601319698&LIC=BONDP**098K1&SAW= 08/06/2014 FILE COPY Permit No, PCB I 0O Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Filet! Copy and coneys is aduacknowledged: By.(7 Date: City Of lbkwila BUILDING DIVISION PLUMBING WASTE AND VENT PLAN PLUMBING DOMESTIC WATER PLAN SCALE: 1/4" = 1'-0" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: echanical Electrical Plumbing Oit Gas Piping City of Tukwila PULDMI,G DIVISION VERIFY ALL CONDITIONS IN FIELD DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR, TO: BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING PLUMBING SYSTEM IS BASED ON RECORD DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. REVIEWED FOR ADDITIONAL NOTES: • FLOOR DRAINS SHALL HAVE TRAP PRIMERS. • NO PVC PIPING ABOVE GRADE. • NO PIPING IN DEMISING WALLS. CODE COMPLIANCE APPROVED MAY 192014 PLUMBING GENERAL NOTES: City of I u ila BUILDING : ISION 1 DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY THE OWNER'S CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID.. 2. FURNISH A CONSTRUCTION RECORD SET OF "AS -BUILT" DOCUMENTS TO THE OWNER'S CONSTRUCTION MANAGER REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS OR EQUIPMENT CONTRARY TO THE CONSTRUCTION DOCUMENTS PREPARED BY THE ENGINEER -OF -RECORD AFTER FINAL INSPECTION OF INSTALLED PLUMBING SYSTEMS. 3. FURNISH TO THE OWNER'S CONSTRUCTION MANAGER A COPY OF INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL REQUIREMENTS OF THE LANDLORD. 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS. 6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE START OF PROJECT. 7. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES. 8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE ROUTING. 9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. 10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE NECESSARY, SHALL BE ROUTED ,AS HIGH. AS POSSIBLE AND TIGHT TO WALLS. 11. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS. 12. COORDINATE PIPING ,9NSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORGINATE"'SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL CONTRACTOR`' AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED. 13. CLEAN FAUCET AER' TORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE OWNER. 14. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES. 15. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROUTE PIPING OVER ELECTRICAL PANELS. 16. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10' MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT. 17. INSULATE PIPING ROUTED IN EXTERIOR BUILDING WALLS WITH MINIMUM 2" BATT INSULATION TO PREVENT FREEZING. 18. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE. 19. PROVIDE CHECK VALVES IN HOT AND COLD WATER SUPPLIES FOR MOP SINK FAUCETS DOWNSTREAM OF SHUTOFF VALVES. 20. GENERAL CONTRACTOR SHALL ROD AND SCOPE WASTE LINE TO LANDLORD'S MAIN PRIOR TO TURNOVER. 21. HARD 90 DEGREE TURNS WILL NOT BE ALLOWED ON WASTE LINES. TURNS MUST BE SWEEPING. PLUMBING PLAN KEYNOTES: (OO ,O,OO ) RECEIVED CITY OF TUKWILA MAY 1.4 2014 PERMIT CENTER 1. CONNECT 4" WASTE LINE. TO EXISTING WASTE LINE. FIELD VERIFY EXACT LOCATION. 2. WATER FILTER, SEE PLUMBING FIXTURE SCHEDULE. 3. COORDINATE INSTALLATION OF WATER FEATURE. REFER TO SHEET A823 FOR MORE INFORMATION. 4. INSTALL WATER CLOSET. ROUGH -IN AND CONNECT 3/4" COLD WATER, 4" WASTE AND 2" VENT. 5. INSTALL LAVATORY. ROUGH -IN AND CONNECT 1/2" HOT WATER, 1/2" COLD WATER, 2" WASTE AND 1-1/2" VENT. 6 INSTALL ELECTRIC WATER HEATER ABOVE MOP SINK. SET DISCHARGE TEMPERATURE TO 110'F. 7. INSTALL KITCHEN SINK. ROUGH -IN AND CONNECT 3/4" HOT WATER, 3/4" COLD WATER, 2" WASTE AND 1-1/2" VENT. 8 INSTALL MOP SINK. ROUGH -IN AND CONNECT 3/4" HOT WATER, 3/4" COLD WATER, 3" WASTE AND 2" VENT. PROVIDE TEMPERING MIXING VALVE (WATTS MMV-US, 3/4" CONNECTION) TO LIMIT THE MAXIMUM HOT WATER TEMPERATURE TO 105'F. 9. CONNECT 1-1/2" COLD WATER LINE TO EXISTING COLD WATER LINE. FIELD VERIFY EXACT LOCATION. PROVIDE WATER SUB -METER WITH REMOTE READER. 10. INSTALL FLOOR DRAIN. ROUGH -IN AND CONNECT 2" WASTE AND 1-1/2" VENT. 11. INSTALL TRAP PRIMER. ROUGH -IN AND CONNECT 1/2" COLD WATER. Dos° MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 DESCRIPTION WASt 43448 9 ' ' EXPIRES 9/21/2015 PLUM3ING FLOO PLAN LULULEO\ ATHLETICA CO\STUCTIO\ STAN3ADS 21 sourHCENree, SUITE gas TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DD-LLD 04/18/14 ISSUE FOR CD-LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By. DP/DB Checked By CF Job Number: 142.0115 Drawing: FLU V3I\G ANNOTATION 0 SY V 3OLS PLUMBING PLAN NOTE CALLOUT PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED 1 AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION THIS IS A NOTE: MASTER ABBREVIATIONS, ETC. ARE LSYMBOLS, ARENEC NECESSARILY USED ON THE DRAWINGS. STANDARD MOUNTING HEIGHTS PLUMBING REFER TO THE ARCHITECTURAL DRAWINGS FOR UNO, INSTALL PLUMBING FIXTURES WITH THE WITH FINAL APPROVAL BY THE ARCHITECT. ADA ACCESSIBLE DRINKING FOUNTAIN ADA ACCESSIBLE LAVATORIES ADA ACCESSIBLE SHOWER VALVES ADA ACCESSIBLE TUB VALVES ADA ACCESSIBLE URINALS ADA ACCESSIBLE WATER CLOSET ADA ACCESSIBLE WATER COOLER ADULT STANDARD DRINKING FOUNTAIN ADULT STANDARD WATER COOLER CHILD STANDARD DRINKING FOUNTAIN CHILD STANDARD WATER COOLER CHILD URINAL CLINIC SERVICE SINKS JANITOR'S SINK FAUCET FITTINGS HOSE BIBBS ICE MAKER OUTLET BOXES LAVATORY OR SINK NON FREEZE HYDRANT SHOWER HEADS SHOWER VALVES STANDARD URINALS SURGEON'S SCRUB -UP SINKS TUB VALVES WASHING MACHINE OUTLET BOXES WATER CLOSET (AFF, AFG, UNLESS NOTED OTHERWISE) PLUMBING FIXTURE MOUNTING HEIGHTS. MOUNTING HEIGHTS AS LISTED BELOW 17" FLOOR TO RIM 34" FLOOR TO RIM 38" MINIMUM TO 48" MAXIMUM FLOOR TO CENTERLINE CENTER BETWEEN GRAB BAR AND TUB RIM 17" FLOOR TO RIM 17" TO 19" FLOOR TO TOP OF SEAT 35" FLOOR TO RIM 40" FLOOR TO RIM 30" FLOOR TO RIM 30" FLOOR TO RIM 14" FLOOR TO RIM 14" FLOOR TO RIM 30" FLOOR TO RIM 42" FLOOR TO CENTERLINE 36" AFF TO CENTERLINE 24" FLOOR TO CENTER OF BOX 31" FLOOR TO RIM 18" AFG TO CENTERLINE 6'-0 MEN & 5'-6" WOMEN FLOOR TO CENTERLINE 48" MEN & 42" WOMEN FLOOR TO CENTERLINE 22" FLOOR TO RIM 35" FLOOR TO FRONT RIM 32" FLOOR TO CENTELINE 42" FLOOR TO RIM 15" FLOOR TO RIM ABBREVIATIONS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT BFF BELOW FINISHED FLOOR BFG BELOW FINISHED GRADE BOP BOTTOM OF PIPE BOS BOTTOM OF STRUCTURE BTU BRITISH THERMAL UNIT CPVC CHLORINATED POLYVINYL CHLORIDE DN DOWN DFU DRAINAGE FIXTURE UNIT DS DOWNSPOUT ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FFA FFB FF FROM FLOOR ABOVE FROM FLOOR BELOW FINISHED FLOOR FL FLOW LINE FLA FULL LOAD AMPS FLR FLOOR GPM GALLONS PER MINUTE HD HEAD, HUB DRAIN IE INVERT ELEVATION IN WC INCHES OF WATER COLUMN JB JUNCTION BOX J—BOX JUNCTION BOX kW KILOWATT MAU MAKE—UP AIR UNIT MAX MAXIMUM MBH 1000 BTU PER HOUR MH MIN N/C N/0 ORD PDI PVC PRV RD RPM RTU SF SP SS SEWER, TDH TFA TFB TYP UL INC. UNO UPS v VCP VS VTR w/ W/0 WC WS WSFU MANHOLE MINIMUM NORMALLY CLOSED NORMALLY OPEN OVERFLOW ROOF DRAIN PLUMBING DRAINAGE INSTITUTE POLYVINYL CHLORIDE PRESSURE REDUCING VALVE ROOF DRAIN REVOLUTIONS PER MINUTE ROOFTOP UNIT SQUARE FEET, SUPPLY FAN SUMP PUMP STAINLESS STEEL, SANITARY SOIL STACK TOTAL DYNAMIC HEAD TO FLOOR ABOVE TO FLOOR BELOW TYPICAL UNDERWRITERS LABORATORIES, UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VOLT(S) VITRIFIED CLAY PIPE VENT STACK VENT THROUGH ROOF WITH WITHOUT WATER COLUMN WASTE STACK WATER SUPPLY FIXTURE UNIT PIPING DOMESTIC COLD WATER (CW) SCW SOFTENED COLD WATER (SCW) DOMESTIC HOT WATER (HW) DOMESTIC HOT WATER RECIRC. (HWR) 140' 140' DOMESTIC HOT WATER (140') T TRAP PRIMER LINE (T) S SOIL PIPING - ABOVE FLOOR (S) S SOIL PIPING - BELOW FLOOR (S) W WASTE PIPING - ABOVE FLOOR (W) W WASTE PIPING - BELOW FLOOR (W) GW GREASE WASTE - ABOVE FLOOR (GW) GW GREASE WASTE - BELOW FLOOR (GW) ST STORM DRAIN - ABOVE FLOOR (ST) ST STORM DRAIN - BELOW FLOOR (ST) OST OVERFLOW STORM DRAIN - ABOVE FLOOR (OST) VBG VENT BELOW GRADE (VBG) VBF VENT BELOW FLOOR (VBF) ID INDIRECT DRAIN (ID) CDH CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH) CD CONDENSATE DRAIN (CD) ACD AUXILIARY CONDENSATE DRAIN (ACD) SPD SUMP OR SEWAGE PUMP DISCHARGE (SPD) G NATURAL GAS (G) G NATURAL GAS ON ROOF (G) -MPG MEDIUM PRESSURE NATURAL GAS (MPG) MPG MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG) NPW NON POTABLE WATER (NPW) LPG LIQUIFIED PETROLEUM GAS (LPG) WS WATER SERVICE (WS) FP FIRE PROTECTION (FP) PD CONDENSATE PUMP DISCHARGE (PD) EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN V VENT PIPING (V) SQUARE FLOOR DRAIN (FS), SIZE & TYPE ROUND FLOOR DRAIN (FD), SIZE & TYPE t0 ROOF DRAIN (RD), SIZE & TYPE lr BALL VALVE CONTROL VALVE SHUTOFF VALVE IV CHECK VALVE BALANCING VALVE WITH PRESSURE PORTS WATER METER Iyi STRAINER STRAINER WITH BLOWOFF - RELIEF/SAFETY VALVE D44 SOLENOID VALVE PRESSURE REDUCING VALVE D1 a GAS PRESSURE REGULATOR THERMOSTATIC MIXING VALVE PA PIPE ANCHOR --oEJ EXPANSION JOINT BACKFLOW PREVENTER PRESSURE GAUGE THERMOMETER UNION FLANGE CONNECTION HOSE BIBB (HB) NONFREEZE WALL HYDRANT (NW) MANUAL / AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE CLEANOUT CAP D-II WALL CLEANOUT (WCO) ® FLOOR CLEANOUT (FCO) o❑ EXTERIOR CLEANOUT (ECO) o ELBOW UP -moo ELBOW DOWN TEE UP TEE DOWN ELBOW UP WITH SHUT-OFF VALVE (SOV) '2 ELBOW DOWN WITH SHUT-OFF VALVE (SOV) TEE UP WITH SHUT-OFF VALVE (SOV) TEE DOWN WITH SHUT-OFF VALVE (SOV) WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D, & E) RECIRCULATION PUMP Do P-TRAP iii GAS COCK e TRAP PRIMER eo TRAP PRIMER WITH DISTRIBUTION UNIT EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN 1 "A" WATER FEATURE HANGERS INSTALLED EACH SIDE OF EXP. TANK FOR SUPPORT BALL VALVE BY P.C. (TYP.) 3/4" RUN FULL SIZE TO FLOOR DRAIN. - - DRAIN VALVE BY P.C. PLATFORM ABOVE MOP SINK RE: ARCHITECTURAL DRAWINGS WASTE AND VENT RISER DIAGRAM NTS BY P.C. VACUUM BREAKER AMTROL ST-5 THERMAL EXPANSION ABSORBER INSULATE ALL PIPING IN ACCORDANCE WITH CW / SPECIFICATIONS. HW—H 6" WH-1 ®WATER HEATER DETAIL 3/4"T & P RELIEF VALVE BY P.C. — WATER HEATER SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. 2" WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. (BY P.C.) GALV. DRIP PAN BY P.C. SEPARATE 3/4" DRAINS TO TO MOP SINK PAINTED TO MATCH COVER PLATE WITH SCREW WATER FEATURE MAY EXTEND AS A WASTE OR VENT WALL PLUGGED TEE WITH CLEAN OUT WALL CLEANOUT DETAIL NTS FLOOR -1 /2"CW KS-1 DOMESTIC WATER RISER DIAGRAM NTS 12" MINIMUM TO HORIZONTAL RUN IN PIPE CONNECT TO FLOOR DRAIN (TYP.) 1 /2 COLD WATER SUPPLY CONNECTION SOLENOID VALVE METAL CABINET AUTOMATIC TRAP PRIMER 1/2" TRAP WATER LEVEL REVIEWELJ r )R CODE COMPLIANCE APPROVED MAY 19 2014 City of Tukwila BUILDING DIVISION FLOOR DRAIN I t TRAP PRIMER DETAIL NTS RECEIVED CITY OF TUKWILA MAY 1 4 2014 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 r i ,, U DESCRIPTION ' 4 r+ Ii) -14 DATE -I z A. 41P '1111. 43448 , ''" o '(. SI 'e' 1. EXPIRES 9/21/2015 LUMBING RISERS AND DETAILS LULULEVON ATHLETICA CO\STUCTO\ STAN3A3S 21 SOUTHCENTER, SUITE I48 TUKWILA, WA 98188 LJ_ ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By. DP/DB Checked By: CF Job Number: 1 42.0115 Drawing: PLUMBING SPECIFICATIONS: SECTION 15200 A. SCOPE OF WORK THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. C. PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED. D. TESTS AND ADJUSTMENTS. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCE'S AND CONFRONTATIONS. RELOCATION OF EXISTING WATER, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES AND THE LANDLORD'S REQUIREMENTS. VERIFY LOCAL ADA AND WATER -SAVING DEVICE 'CODE REQUIREMENTS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL SUBMIT A REPRODUCIBLE COPY OF THE "AS -BUILT" DRAWING TO THE LANDLORD AND TO THE OWNER FOR THEIR RECORDS. B. PLUMBING EQUIPMENT PROVIDE NEW PLUMBING EQUIPMENT AS SHOWN ON THE DRAWING AND SPECIFIED IN THE PLUMBING FIXTURE SCHEDULE. WHERE EXISTING PLUMBING FIXTURES ARE TO BE REUSED, REPLACE BALL COCK VALVE SEALS, LEAVE IN PROPER WORKING ORDER. C. GENERAL PIPING REQUIREMENTS 1. GENERALLY, SANITARY AND POTABLE WATER CONNECTIONS WILL BE MADE AT TOILET ROOM AND OTHER PLUMBING FIXTURES SHOWN ON PLANS. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY THE TENANT'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM OF 50 PSI. 2. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. 3. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. 5. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT'S DEMISED PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO OTHER TENANTS AND/OR TO THE BUILDING. FAILURE TO DO SO SHALL BE AT RISK AND SOLE EXPENSE OF THE CONTRACTOR. D. PIPING SANITARY PIPING - NO PVC ALLOWED A. WASTE AND DRAIN PIPING SHALL BE SERVICE WEIGHT, CAST IRON SOIL PIPE. ALL VENT PIPING SHALL BE CAST IRON. NO -HUB JOINTS: BELOW FLOOR SLAB - COMPRESSION TYPE PLATIC SEAL (HUB AND SPIGOT). ABOVE FLOOR SLAB - NEOPRENE SEALING SLEEVE WITH STAINLESS STEEL SHIELD AND CLAMP WITH APPROVED NEOPRENE - BASED LUBRICANT, (HUBLESS). B. PITCH WASTE LINES 2" AND SMALLER NOT LESS THAN 1/4" PER FOOT. PITCH LARGER MAINS NOT LESS THAN 1/8" PER FOOT. C. INSTALL A CLEANOUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOWN ON DRAWINGS OR REQUIRED BY LOCAL CODE. CLEAN OUTS SHALL ONLY BE INSTALLED IN NON-PUBLIC AREAS, UNLESS GIVEN EXPRESSED WRITTEN PERMISSION BY TENANT'S CONSTRUCTION MANAGER. WHEN GIVEN PERMISSION TO INSTALL IN PUBLIC AREAS, THE CLEANOUTS SHALL HAVE STAINLESS STEEL WALL COVERS AND BRASS FLOOR COVERS (FLUSH WITH FINISHED FLOOR) PROVIDED BY THE CONTRACTOR. PROVIDE COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN -OUT LOCATIONS SHALL BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER. D. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING, SEE #5. E. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAV GUARD" INSULATION KIT. 2. CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER TUBE WITH 95-5 TIN -ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING: A. BELOW GRADE: TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ABOVE GRADE: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5 TIN -ANTIMONY SOLDER. C. INSTALL SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. D. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. E. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS FOR FOR ADDITIONAL INFORMATION. F. SECURE PIPE AT ANGLE STOPS. G. PROVIDE FLEXIBLE INSERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION. 4. GAS PIPING - NOT APPLICABLE 5. INSULATION A. INSULATE ALL WATER AND INTERIOR CONDENSATE PIPING WITH 1" THICK (K=0.23 0 75 F) SNAP -ON FIBERGLASS PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATINGS OF 50. APPROVED MANUFACTURER: MANVILLE MICRO-LOK. 6. TEST & STERILIZATION A. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: B. TEST POTABLE WATER PIPING AND CONDENSATE PIPING AT 125 PSIG FOR SIX HOURS. C. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. ALL JOINTS SHALL BE GAS AND WATER TIGHT. D. STERILIZE POTABLE HOT & COLD WATER LINES UPON COMPLETION OF SYSTEM. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. FIELD VERIFY ALL CO \DITION S DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. PLUV311\G FIXTURE SCHEDULE MARK CONNECTIONS MANUFACTURER/ MODEL NUMBER HW CW V W WC-1 WATER CLOSET (ADA) ELONGATED COMBINATION TOILET, 12" ROUGH -IN, POLISHED CHROME TRIP LEVER, VITREOUS CHINA, 1.6 GPF, EQUIPPED WITH CLASS 5 FLUSHING SYSTEM, 16-1/2" RIM HEIGHT, ADA COMPLIANT. INSTALL WITH TRIP LEVERS ON THE WIDE SIDE OF THE STALL. -- 3/4" 2" 4" STANDARD KOHLER/K-3589 TANK/BOWL-COMBO SEAT HEAVY DUTY, ELONGATED, OPEN FRONT LESS COVER, SELF SUSTAINING CHECK HINGE. OLSONITE/95SSC SUPPLIES 1/2" CHROME PLATED BRASS TUBING WITH BALL VALVE ANGLE STOPS. W - $IE____17t241'HROME CLOSET (ADA) ELONGATED COMBINATION TOILET, 12" ROUGH -IN, POLISHED TRIP LEVER, VITREOUS CHINA, 1.28 GPF, 16-1/2" RIM HEIGHT, LIANT. INSTALL WITH TRIP LEVERS ON THE WIDE SIDE OF TH -- 3/4" . 2" 4" CALIFORN AN STANDARD CADET 3 FLOWISE TANK/BOWL-COMBO SEAT HEAVY DUTY, ELONGATED, OPE SS COVER, SELF SUSTAINING CH OLSONITE/95SSC PLATED BRASS TUBING WITH BALL VALVE ANGLE STOPS. L-1 LAVATORY/ADA "LUCERNE" WALL -HUNG LAVATORY, VITREOUS CHINA, FRONT OVERFLOW, D-SHAPED BOWL, SELF -DRAINING DECK, FAUCET LEDGE, FAUCET HOLES ON 4" CENTERS 1/2'' 1/2'' 1-1/2" 2" AMERICAN STANDARD 0355.012 FAUCET "AQUASENSE" HARDWIRED ELECTRONIC SENSOR FAUCET, INTEGRAL FOUR INCH COVER PLATE, INFRARED CONVERGENCE -TYPE PROXIMITY SENSOR LOCATED IN THE CHROME PLATED CAST BRASS SPOUT, IN -LINE FILTER, 0.5 GPM VANDAL RESISTANT AERATOR, THERMOSTATIC MIXING VALVE FOR SINGLE FAUCETS, INCLUDES FOUR 'AA' BATTERIES TO PROVIDE BATTERY BACKUP POWER TO THE FAUCET DURING POWER OUTAGES, SENSOR RANGE IS FACTORY SET FOR OPTIMUM PERFORMANCE ZURN Z6915-HW6-CWB-F-TMV-1 SUPPLIES 3/8" CHROME PLATED ANGLED STOP WITH WHEEL HANDLE, 3/8" CHROME PLATED FLEXIBLE BRASS RISER, INSULATE ALL EXPOSED WATER LINES AND VALVES WASTE GRID DRAIN, 4-1/2" OFFSET FOR WHEELCHAIR LAVATORY, 1-1/4" TAILPIECE, 1-1/4" 17 GAUGE CHROME PLATED ADJUSTABLE BRASS P-TRAP WITH CLEANOUT PLUG RUN PARALLEL AND AS TIGHT TO WALL AS POSSIBLE, 1-1/4" CHROME PLATED BRASS WASTE TO WALL AMERICAN STANDARD 7723.018 CARRIER LAVATORY SUPPORT SYSTEM WITH TOP SUPPORT PLATE, DURA-COATED RECTANGULAR STEEL UPRIGHTS WITH WELDED FEET, ADJUSTABLE SUPPORT PLATE, AND MOUNTING FASTENERS ZURN/Z-1224 PROTECTIVE PIPE COVER ONE P-TRAP COVER, TWO ANGLE VALVES AND SUPPLY COVERS, ONE 5" OFFSET TAILPIECE WHEELCHAIR STRAINER COVER TRUEBRO/103 E-Z MOUNTING HEIGHT 33 INCHES FLOOR TO RIM KS-1 SINK "LUSTERTONE" SINGLE BOWL, SEAMLESSLY FORMED OF #18 GAUGE, TYPE 304 (18-8) NICKEL BEARING STAINLESS STEEL, SELF -RIMMING, FULLY UNDERCOATED UNDERSIDE TO DAMPEN SOUND AND PREVENT CONDENSATION, 6" BOWL DEPTH, 17"X16" OVERALL DIMENSIONS, 3 HOLES ON 4" CENTERS 3/4" ' 3/4" ,. 1-1/2" 2" ELKAY/LRAD1716 FAUCET DUAL HANDLE TOP MOUNT MIXING FAUCET, GOOSENECK SWING SPOUT, HEAVY CHROME PLATE, REMOVABLE CARTRIDGES, 1/2" I.P. CONNECTIONS, 4" BLADE HANDLES. PROVIDE WITH 1.5GPM AERATOR. ELKAY/LKD2432BH SUPPLIES 1/2" CHROME PLATED ANGLE STOPS WITH LOOSE KEY HANDLE, 1/2" CHROME PLATED FLEXIBLE BRASS RISER WASTE STANDARD DUO STRAINER, FITS 3 1/2" OPENING (4-1/2" TOP DIAMETER), ONE PIECE STAINLESS CONICAL STRAINER BASKET WITH NEOPRENE STOPPER, CHROME PLATED BRASS TAILPIECE, 1-1/2" 17 GAUGE CHROME PLATED ADJUSTABLE P-TRAP WITH CLEANOUT PLUG, 1 1/2" CHROME PLATED BRASS WASTE TO WALL ELKAY/LK-35 TP-1 TRAP PRIMER MACHINED OF CORROSION RESISTANT BRASS CONTAINS NO SPRINGS OR DIAPHRAGMS, INLET 1/2" MALE NPT, OUTLET 1/2" FEMALE NPT. PRESSURE ACTIVATED PRIMER DELIVERS POTABLE WATER ACROSS AN AIR GAP FUNNEL THEN THROUGH THE DISTRIBUTION UNIT WHEN IT SENSES A PRESSURE DROP OF 5 TO 10 P.S.I.G. -- 1/2" -- -- PRECISION PLUMBING PRODUCTS INC. / P2-500 MOUNTING HEIGHT MINIMUM MOUNTING HEIGHT OF 12" ABOVE FINISHED FLOOR WHEN FLOOR DRAIN SERVED IS 20'-0" OR LESS DEVELOPED LENGTH FROM UNIT, MOUNT AN ADDITIONAL 12" HIGHER FOR EACH ADDITIONAL 20"-0" OF LENGTH SUPPLIES DISTRIBUTION UNIT DU-2 FOR 1 OR 2 TRAPS, DU-3 FOR 3 TRAPS, OR DU-4 FOR 4 TRAPS, TO SUPPLY MORE THAN FOUR TRAPS ADD DISTRIBUTION UNIT PAIRS UP TO 8 DRAINS, PROVIDE AG-500 AIR GAP CONNECTION. FD-1 FLOOR DRAIN COATED CAST IRON FLOOR DRAIN, TWO-PIECE BODY, DOUBLE DRAINAGE FLANGE, INVERTIBLE NON -PUNCTURING FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET INSIDE CAULK CONNECTION, ADJUSTABLE ROUND SUPER-FLO STRAINER, FLASHING CLAMP WITH 20"x24" 4 LB. LEAD FLASHING FOR FLOOR DRAINS INSTALLED ABOVE SLAB ON GRADE, 1/2" TRAP PRIMER CONNECTION. -- -- 1-1/2" 2" ZURN/Z-415S-P ZURN/TYPE 5 STRAINER 6" x 6" SQUARE NICKEL BRONZE FINISH WASTE CAST IRON P-TRAP UNDER FLOOR WCO _ WALL CLEANOUT COATED CAST IRON CLEANOUT TEE, HUB AND SPIGOT CONNECTION, BRONZE PLUG. -- -- -- SEE PLANS ZURN/Z1468 FCO OUT ZURN MODEL #ZB-1400 DURA-COATED CAST IRON BODY, "LE - ABLE FLOOR CLEANOUT, INSIDE CAULK CONNECTION WITH GAS AND S TAPERED THREAD INTERNAL PLUG ADJUSTABL SCORIATED OP, POLISHED BRONZE , INSTALL FLUSH WITH FINISHED FLOOR. -- -- -- -- _ 0 MS-1 MOP SINK MOLDED STONE, 2" CHROME STRAINER, WITH PAIL HOOK, HOSE THREAD, VACUUM BREAKER, WALL SUPPORTS, SUPPLIES WITH TEE OPS, P-TRAP, RIM GUARD 3/4" 3/4" 2" 3" FIAT/MODEL MSB-2424 FAUCET SERVICE SINK FAUCET -- -- -- -- FIAT/MODEL 830AA WF-1 REMOTE WATER FILTER INLINE POTABLE WATER FILTRATION SYSTEM. INSTALL WATER FILTER PER MANUFACTURER'S RECOMMENDATIONS. IF SUPPLIED WATER PRESSURE EXCEEDS 125 PSI, PROVIDE FILTER WITH PRESSURE LIMITING VALVE. -- 3/4" -- -- AQUA -PURE AP200 SYSTEM WITH AP217 FILTER SH-1 S ADA ACCESSIBLE PISTON TYPE PRESSURE BALANCING MIXING VALVE WITH MEETING ASSE 101.6P, SINGLE BLADE LEVER HANDLE, ADJUSTA P SCREW SET AT 110F, INTEGRAL SERVICE STOPS, "TEMPTR RE BALANCING MIXING VALVE, "CLEAR-FLO" ARM AND FLANGE SHOWER WITH FLEXIBLE M -LINE VACUUM BREAKER, WALL CONNECTION AND FLANGE, AND 30" SLIDE BAR. 3/4" 3/4" 1-1/2" 2" S 5-500-B30-V ELECTS I C WATER HEATE MARK LOCATION KW GA L HRC 100' / DEGREE RISE; ELECTRICAL STORAGE CAP MANUFACTURER REMARKS VOLTS PHASE EWH-1 PLATFORM 2.5 10 120 SINGLE 6 GALLONS A.O. SMITH MODEL NO. DEL-6 EXPANSIO\ TAB\ 'S MARK LOCATION SERVES CAPACITY j (GALLONS) WORKING PRESS (PSI) SIZE (APPROX) MANUFACTURER REMARKS ET-1 PLATFORM DOM. HW 0.9 150 12-5 8"0x8" / AMTROL MODEL ST-5* *CONTRACTOR SHALL ADJUST PRE -CHARGE OF TO INSTALLATION. EXPANSION TANK TO EQUAL INCOMING WATER PRESSURE PRIOR REV CO P FOR CODE COMPLIANCE APPROVED MA(192014 City of Tukwila BUILDING DIVISION FGIoo9 RECEIVED CITY OF TUKWILA MAY 142014 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5.150 J N i V DESCRIPTION M 0 DATE -4 zz o WA ,, s,:,,,,;4:48 d': S 1Z EXPIRES 9/21/2015 'LUMBING SCHEDULES LULULEVO\ ATHLETICA CO\STUCTIO\ STA\DADS 21 SOUTHCENTER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL- 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By. DP/DB Checked By. CF Job Number: 142 0115 Drawing: