Loading...
HomeMy WebLinkAboutPermit PG14-0098 - VICTORIA'S SECRET - RESTROOMS REMODELVICTORIA'S SECRET 230 SOUTHCENTER MALL PG1 4-0098 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 9202470130 Permit Number: PG14-0098 Address: 230 SOUTHCENTER MALL Issue Date: 8/18/2014 Permit Expires On: 2/14/2015 Project Name: VICTORIA'S SECRET Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, CA, 92013 Contact Person: Name: MARY RYAN Phone: (949) 582-3735 Address: PO BOX 3749 , MISSION VIEJO, CA, 92690 Contractor: Name: BURK MECHANICAL LLC Phone: (360) 340-7268 Address: 7583 CLOVER VLY RD SE , PORT ORCHARD, WA, 98367 License No: BURKMML886D2 Expiration Date: 3/22/2016 Lender: Name: Address: , , , DESCRIPTION OF WORK: REMODEL OF EXISTING RESTROOMS - (2) RESTROOMS, DRINKING FOUNTAIN, AND MOP SINK. Valuation of Work: $28,000.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $272.36 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 ,i,e_6(4 aiP-1 2012 2012 2012 Date: 06/(P/7 V I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: I I Oil 1 y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print* * SITE LOCATION V Site Address: j\ rSO i+hC€ fl1 R,1U 4AJi IC, ,USA citb lb2 Suite Number: 100 Floor: 1 Tenant Name: V 1 C;' O ((AIL C G PROPERTY OWNER Name: 0Sfifl6I 4 it, „.... Address: I I (i01 t/l)I I1 h ire, aVCi, r I00t? t City: 1 O S i�Y1G1 L LC. I State: ,, A Zip:g0 )Zq CONTACT PERSON — person receiving all project communication Name: p Ac �� Address: Pu ox c 31401 City: fliS((o,i vit 0 State: riA Zipe)21Gc) a Phone:om6t3 Z111i7 Fax: cg11prb93'f3 ( U Email: (ma1zu ra?>✓mA-R?. OuPut,k. (DM King Co Assessor's Tax No.: New Tenant: ❑ Yes [1 ..No PLUMBING CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $_ Scope of Work (please provide detailed information): —maw-- — OF CC i r- - 1)— (s 4— W I ) F CI ►--L.S ; LA K. rion Building Use (per Intl Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water oiktAucriw Sewer H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sink I Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) In Lavatory O" Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment 1 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 9's Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain I Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED GENT: Signature: 1'� Date: Print Name: b /� G 2.-t 1 R Mailing Address: P o ?)--11401, Day Telephone: t\-411:D161 V, a City CA Q State Zip H:\Applications'Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID $217.18 PG14-0098 Address: 230 SOUTHCENTER MALL " Apn::9202470130 2171 PLUMBING $206.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $121.82 PLAN CHECK FEE R000.322.103.00.00 0.00 $52.38 TECHNOLOGY FEE $10.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2891 R000.322.900.04.00 0.00 $10.48 $217.18 Date Paid: Monday, August 18, 2014 Paid By: TAMMY BURK Pay Method: CREDIT CARD 024124 Printed: Monday, August 18, 2014 3:59 PM 1 of 1 I?W SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $4,347.87 D14-0173 Address: 230 SOUTHCENTER MALL Apn: 9202470130 $3,575.85 DEVELOPMENT $3,575.85 PLAN CHECK FEE R000.345.830.00.00 0.00 $3,575.85 EL14-0540 Address: 230 SOUTHCENTER MALL Apn: 9202470130 $454.41 ELECTRICAL $454.41 PLAN CHECK FEE R000.345.832.00.00 0.00 $454.41 M14-0118 Address: 230 SOUTHCENTER MALL Apn: 9202470130 $262.43 MECHANICAL $262.43 PLAN CHECK FEE R000.322.102.00.00 0.00 $262.43 PG14-0098 Address: 230 SOUTHCENTER MALL Apn: 9202470130 $55.18 PLUMBING $55.18 PERMIT FEE TOTAL FEES PAID BY RECEIPT: R2315 R000.322.100.00.00 0.00 $55.18 $4,347.87 Date Paid: Tuesday, June 10, 2014 Paid By: PERMIT RESOURCES INC. Pay Method: CHECK 22548 Printed: Tuesday, June 10, 2014 8:46 AM 1 of 1 sr ?(,`-I-oos ern N INSPECTION RECORD Retain a copy with permit N4AottL&' INSPECTfON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: , /"'" V t c' t �, - ‘-------n �I Type f Ins ection:- � � Address: . 11— .$0 'NM " t ! k;I , Date Called: r t ^1 A L.— Pt ►,t vikg. m Co Special Instructions: Date Wanted: t�`a.ixi' 1C) ---- 2L-4_. (4- p.m. Requester: Phone No: Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: c K fits etcNel- 7)iosii .Cc ct (.^ )F de i /t- l N 4L ____ TC' ( it l ,� Et-v1> 1 Date: b-2`l— )2/ Inspec r: (EINSPECTION FEE REQUIRED. Prick to next inspection, fee must be +paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPI:OTIBN N INSPECTION RECORD Retain a copy with permit PERMIT NO. I LL CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Prole ` , - t tiA -' 'n�" ,' T Inspection: 1 INJet t Address: ` 4 �� Date Called: S ecia Instructions: Date Wanted: / 1 Lam-' f j f m i P.m - Requester: Phone No: ElApproved per applicable codes. t!lCorrections required prior to approval. COMMENTS: 6R INSPECTION FEE REQUIRED. Prior to next inspection. fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ooq Project; \,I �(l)Y \d!\S S'�'C Type of Inspectio i\• - N. h Address: 21,c> S0OICVf-^)v\k-4,'f Yk\\ Date Called: �— \\--\Lt ..� Special Instructions: ' Date Wanted: ,- '� a.m Requester Phone No: k i Approved per applicable codes. t�J Corrections required prior to approval. COMMENTS: K C3 J rA i _ST-5 Inspector: Date: REINSPECTION FE EQUIRED. Prior tb—next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 r?r3006 Project: `�v 04 ; ceciv Type oflnspectiionn: jz 1 �,{� �� ��(t)?/R%t't Address: Date Called: Special Instructions: Date Wanted: - 1 Cj , 1 L' "'a.m.. Lp,m. Requester: Phone No: Approved per applicable codes. t_..A Corrections required prior to approval. COMMENTS: it) / tfPAl or: \NN\4. .n..c, ..RJe,. 2c REINSPECTION FEE REQUIRED. Prior to n xt inspection, fee must be i paid at 6300 Southcenter Blvd.. Suite 100. Gall to schedule reinspection. Dato BACKFLOW ASSEMBLY TEST REPORT BATman Testing„, 13ACKFLOW ASSEMBLY TESTING AND REPAIR 'Gcvt• oon CUSTOMER / FACILITY NAME Victoria's Secret CONTACT / OWNER NAME WATER PURVEYOR CITY OF TUKWILA NEW CONSTRUCTION ASSEMBLY / CUSTOMER ID# PHONE NUMBER ( ) - FAX NUMBER ( ) - PURVEYOR CONTACT NAME Todd Reedy ►=� Y ■ N SERVICE ADDRESS / METER NUMBER 303 Southcenter Mall, Space #100 CUSTOMER / OWNER / CONTACT MAILING ADDRESS PURVEYOR FAX NUMBER (206) 575-3404 CITY / STATE Tukwila WA ZIP CODE 98188-2844 CITY / STATE ZIP CODE - PURVEYOR EMAIL ADDRESS todd.reedy@tulcwila.gov ASSEMBLY MANUFACTURER WATTS MODEL LF009QT SERIAL NUMBER 40613 TYPE RPBA SIZE 1/2" DOWNSTREAM PROCESS STEAMER LOCATION OF ASSEMBLY In back of storage room to right of steamer CONFINED SPACE • YES ►ENO INSTALLATION TYPE ►� New • Existing ■ Replacement PREVIOUS MAKE / MODEL / SIZE / SERIAL NUMBER DETECTOR READ N/A DOH APPROVED ►� ASSEMBLY YES (SEPT 2012 UST) In NO ORIENTATION H PROPER ►j INSTALLATION YES ■ NO WATER LINE PRESSURE 40PSIG VALVE POSITIONS SOV#1 PRIOR TO TESTING ■ON ►/OFF SOV#2 ION LOFF INITIAL TEST RESULTS TEST AFTER REPAIRS/CLEANING RPBA CHECK VALVE #1 CLOSED TIGHT LEAKED RELIEF VALVE OPENED AT CHECK VALVE #1 CLOSED TIGHT LEAKED RELIEF VALVE OPENED AT 4 ii ii 4.1 PSID PSID FAILED TO OPEN CHECK VALVE #2 CLOSED TIGHT LEAKED ACTUAL PRESSURE DROP ACROSS CHECK VALVE #1 PASSED TEST FAILED TO OPEN CHECK VALVE #2 CLOSED TIGHT LEAKED ACTUAL PRESSURE DROP ACROSS CHECK VALVE #1 PASSED TEST APPROVED AIR GAP II 1 ii Ill 7.7 PSID ii PSID ►Z.1 YES ONO ■ YES ■ NO CLEAN / REPAIR: NI see remarks APPROVED AIR GAP YES III NO I YES ENO DVA CHECK VALVE #1 CLOSED TIGHT LEAKED CHECK VALVE #2 CLOSED TIGHT LEAKED PASSED TEST PSID CHECK VALVE 41 CLOSED TIGHT LEAKED CHECK VALVE #2 CLOSED TIGHT LEAKED PASSED TEST PSID • PSID PSID • ■ YES ■ NO ■ YES ■ NO CLEAN / REPAIR: ill see remarks REMARKS VALVE POSRONS AFTER TESTING SOV#1 ■ON ►DOFF SOV#2 ■ON ►DOFF TESTER NAME Jason A. Moe BAT CERTIFICATION B4536 TEST GAUGE MAKE Mid -West GAUGE MODEL 845-5 TEST GAUGE SERIAL NUMBER 03051790 GAUGE CALIBRATION DATE 01/09/2014 REPAIRED BY N/A COMPANY NAME PHONE NUMBER ( ) - FINAL TEST BY N/A BAT CERTIFICATION TEST GAUGE MAKE GAUGE MODEL COMPANY NAME BATman Testing PHONE NUMBER (206) 228-1618 SIGNATURE 7 DATE OF FINAL TEST 10/16/2014 (I HEREBY CERTIFY THAT I USED WAC 246-290-490 APPROVED, USC 10"' Edition TEST METHODS AND DIFFERENTIAL PRESSURE TEST EQUIPMENT FOR THE ABOVE TEST RESULTS) BACKFLOW ASSEMBLY TEST REPORT I3ATman Testincin, RACKFLOW ASSEMBLY TESTING AND REPAIR CUSTOMER / FACUTY NAME Victoria's Secret CONTACT / OWNER NAME WATER PURVEYOR CITY OF TUKWILA NEW CONSTRUCTION ASSEMBLY / CUSTOMER 105 PHONE NUMBER ( ) - FAX NUMBER ( ) - PURVEYOR CONTACT NAME Todd Reedy L Y ■ N SERVICE ADDRESS / METER NUMBER 303 Southcenter Mall, Space #100 CUSTOMER / OWNER / CONTACT MAILING ADDRESS PURVEYOR FAX NUMBER (206) 575-3404 CITY / STATE Tukwila WA ZIP CODE 98188-2844 CITY / STATE ZIP CODE - PURVEYOR EMAIL ADDRESS todd.reedy@tukwila.gov ASSEMBLY MANUFACTURER WATTS MODEL LF009M2QT SERIAL NUMBER 028275 TYPE RPBA SIZE 1" DOWNSTREAM PRO(Fc5 DOMESTIC SERVICE LOCATION OF ASSEMBLY In back above mop sink CONFINED SPACE ■ YES ► y NO INSTALLATION TYPE 0 New • Existing • Replacement PREVIOUS MAKE / MODEL / SIZE / SERIAL NUMBER DETECTOR READ N/A DOH APPROVED ►� ASSEMBLY YES (SEPT 2012 LIST) • NO ORIENTATION H PROPER e INSTALLATION YES ■ NO WATER LINE PRFc ' IRE 55 PSIG VALVE POS0ONS SOV#1 PRIOR TO TESTING 0 ON ■ OFF SOV#2 0 ON IN OFF INITIAL TEST RESULTS TEST AFTER REPAIRS/CLEANING RPBA CHECK VALVE #1 CLOSED TIGHT LEAKED RELIEF VALVE OPENED AT FAILED TO OPEN CHECK VALVE #2 CLOSED TIGHT LEAKED ACTUAL PRESSURE DROP ACROSS CHECK VALVE #1 PASSED TEST CHECK VALVE #1 CLOSED TIGHT LEAKED RELIEF VALVE OPENED AT ►1 ■ ■ ■ 2.6 PSID PSID FAILED TO OPEN CHECK VALVE #2 CLOSED TIGHT LEAKED ACTUAL PRESSURE DROP ACROSS CHECK VALVE #1 PASSED TEST APPROVED AIR GAP ■ ■ ►�/ I ■ 9.0 PSID ■ PSID YES ■ NO ■ YES ■ NO CLEAN / REPAIR: ■ see remarks APPROVED AIR GAP 0 YES ■ NO ■ YES ■ NO DCVA CHECK VALVE #1 CLOSED TIGHT LEAKED CHECK VALVE #2 CLOSED TIGHT LEAKED PASSED TEST PSID CHECK VALVE #1 CLOSED TIGHT LEAKED CHECK VALVE #2 CLOSED TIGHT LEAKED PASSED TEST PSID ■ ■ PSID PSID ■ • EYES ■ NO ■ YES ■ NO CLEAN / REPAIR: • see remarks REMARKS VALVE POSTIONS AFTER TESTING SOV#1 ON ■OFF SOV#2 ►SON ■OFF TESTER NAME Jason A. Moe BAT CERTIFICATION B4536 TEST GAUGE MAKE Mid -West GAUGE MODEL 845-5 TEST GAUGE SERIAL NUMBER 03051790 GAUGE CAUBRATION DATE 01/09/2014 REPAIRED BY N/A COMPANY NAME PHONE NUMBER ( ) - FINAL TEST BY N/A BAT t±RIIHCATION TEST GAUGE MAKE GAUGE MODEL COMPANY NAME BATman Testing PHONE NUMBER (206) 228-1618 SISIGNATURE=7 _ DATE OF FINAL TEST 10/16/2014 (I HEREBY CERTIFY THAT I USED WAC 246-290-490 APPROVED, USC 10th Edition TEST METHODS AND DIFFERENTIAL PRESSURE TEST EQUIPMENT FOR THE ABOVE TEST RESULTS) PERMIT COOED COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0098 PROJECT NAME: VICTORIA'S SECRET DATE: 06/10/2014 SITE ADDRESS: 230 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: by 4WC 6.1(041 Building Division a Fire Prevention W N \ (AO V41 Public Works e Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/12/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n n (corrections entered in Reviews) DUE DATE: 07/10/14 Approved with Conditions Denied (ie. Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 BURK MECHANICAL LLC Page 1 of 2 11.11114 Washington State Department of Labor & Industries BURK MECHANICAL LLC Owner or tradesperson BURK, TAMMY YVONNE Principals BURK, TAMMY YVONNE, PARTNER/MEMBER BURK, JONATHAN DAVID, PARTNER/MEMBER Doing business as BURK MECHANICAL LLC WA UBI No. 603 191 910 7583 CLOVER VLY RD SE PORT ORCHARD, WA98367 360-340-7268 KITSAP County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties PLUMBING License no. BURKMML886D2 Effective — expiration 03/22/2012— 03/22/2016 Bond Great American Ins Co of NY Bond account no. 7902865511473 Active. Meets current requirements. $6, 000.00 Received by L&I Effective date 03/22/2012 03/21/2012 Expiration date Until Canceled Insurance Country Mutual Ins Co $2,000,000.00 Policy no. AM9121359 Received by L&I Effective date 11/12/2013 03/19/2013 Expiration date 03/19/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603191910&LIC=BURKMML886D2&SAW= 08/18/2014 PLUMBING & FIRE PROTECTION RESPONSIBILITY SCHEDULE ITEM FURNISHED BY INSTALLED BY RE -USE EXISTING N/A REMARKS LSD&C VENDOR LANDLORD CONTR. LANDLORD CONTR. OTHER PLUMBING FIXTURES & TRIM GC GC UNLESS OTHERWISE NOTED DRINKING FOUNTAIN AND ASSOCIATED ACCESSORIES. LD GC SEWER AND VENT PIPING GC GC TANK WATER HEATER GC GC DOMESTIC HOT AND COLD WATER PIPING GC GC CONDENSATE DRAIN PIPING GC GC SECOND CONDENSATE DRAIN PIPING GC GC CONDENSATE DRAIN PUMP GAS PIPING FLOOR DRAINS, CLEANOUTS, WATER HAMMER ARRESTORS, ETC. GC GC INSTANTANEOUS WATER HEATER DREAMSTEAMER LD GC FOR VS STORES ONLY DREAMSTEAMER DRAIN PIPING GC GC FOR VS STORES ONLY SPRINKLER PIPING FPC FPC SPRINKLER HEADS FPC FPC FIRE EXTINGUISHERS FPC FPC AS-BUILTS DRAWINGS GC ABBREVIATIONS, RESPONSIBILITY SCHEDULES FPC FIRE PROTECTION CONTRACTOR AHJ AUTHORITY HAVING JURISDICTION GC GENERAL CONTRACTOR LC LANDLORD CONTRACTOR LD LIGHTING PACKAGE DISTRIBUTOR LL LANDLORD LSD&C LIMITED STORE DESIGN & CONSTRUCTION MC MECHANICAL CONTRACTOR RESPONSIBILITY SCHEDULE-VS/PINK NTS 05N-P0101-LOO-SCHD L Oq/13/13 ITEM WC-1 LAV-2 I FIXTURE WATER CLOSET TANK TYPE DF-1 I MS 1NI-I-2 TP FD LAVATORY (ASSOCIATE AMENITY ROOM) NCO FCO GO ROUGH -IN SERVICES 12121111111:11:1 Y" DRINKING FOUNTAIN SK I TMV ABBREVIATIONS - PLUMBING AD ADA AFF AP CD CFM CI CO CONT CONTR COTG CW ACCESS DOOR AMERICAN DISABILITY ACT ABOVE FINISHED FLOOR ACCESS PANEL CEILING DIFFUSER OR CONDENSATE DRAIN CUBIC FEET PER MINUTE CAST IRON CLEANOUT CONTINUE CONTRACTOR CLEANOUT TO GRADE COLD WATER DET DETAIL DF DRINKING FOUNTAIN DL DOOR LOUVER DS DREAMSTEAMER DTR DOWN THRU ROOF DWG DRAWING (E) EXISTING EWC ELECTRIC WATER COOLER FCO FCU FD FOIC FPC FPS FS FLOOR CLEANOUT FAN COIL UNIT FLOOR DRAIN FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FIRE PROTECTION CONTRACTOR FEET PER SECOND FLOOR SINK G GAL GC GPM HB HD HP HW INV LAV LB LF MECH MFR MTD MTR (N) N.C. N.I.C. N.O. N/A NTS P PC PD PLBG GAS GALLONS GENERAL CONTRACTOR GALLONS PER MINUTE HOSE BIBB HEAD HORSEPOWER HOT WATER INVERT LAVATORY POUND UNEAL FEET MECHANICAL MANUFACTURER MOUNTED MOTOR NEW NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NOT APPLICABLE NOT TO SCALE PUMP PLUMBING CONTRACTOR PRESSURE DROP PLUMBING PM POC PRV PSI PROJECT MANAGER POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH (R) RELOCATE RD ROOF DRAIN RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTION PER MINUTE SCH SOV UH UON UTR SCHEDULE SHUT-OFF VALVE OR SCHEDULE OF VALVE UNIT HEATER UNLESS OTHERWISE NOTED UP THRU ROOF VTR VENT THRU ROOF WC WCO WG WH WHA WT WATER CLOSET WALL CLEANOUT WATER GAUGE WATER HEATER WATER HAMMER ARRESTER WEIGHT PLUMBING ABBREVIATIONS NTS OON-P0101-JOO-ABBR J 0c1/06/13 MOP SINK WATER HEATER TANK TYPE TRAP PRIMER FLOOR DRAIN Y2" Y2" Y2" 4" 2" 2" 3" 2" or 11r" DESCRIPTION KOHLER "HIGHLINE PRESSURE LITE" MODEL NO. K-3519-T, 1.1 GPF, PRESSURE ASSISTED WHITE WATER CLOSET WITH ELONGATED VITREOUS CHINA BOWL, (OR ZURN MODEL Z5561-VL, 1.0 GPF WITH HIGH PERFORMANCE ECOFLUSH TECHNOLOGY), 17Ys" HIGH, WHITE OPEN FRONT SEAT AND COVER #K-4650. FURNISH WITH BOLT CAPS AND CHROME SUPPLY STOP. (FOR PUBLIC AND NON-PUBLIC RESTROOMS). FLUSH LEVER SHALL BE LOCATED ON THE WIDE SIDE OF THE TOILET. KOHLER K-2084-(L/R)-0 "SOHO" 20" X 18" WALL HUNG SINK. FURNISH WITH CONCEALED ARM WALL HANGER, CHROME SUPPLY STOPS AND P-TRAP. CHICAGO FAUCET, MANUAL 103/4" GOOSENECK FAUCET 2302-ABCP WITH POP-UP DRAIN AND 0.5 GPM AERATOR. INSULATE P-TRAP AND SUPPLY ONES WITH Xi" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR EQUIVALENT. MOUNT AT HEIGHT DIRECTED BY THE ARCHITECT. 1111111111111 HALSEY TAYLOR SELF-CONTAINED, BARRIER -FREE, ELECTRIC, REFRIGERATED, WALL -MOUNTED, BI-LEVEL WATER COOLER WITH GLASS FILLER KIT #HTV8BL-Q-9685CA. FURNISHED WITH PLUG-IN, 3-WIRE GROUNDING TYPE SERVICE CORD. STANDARD 120V, 60 HZ, 1PH. 120V RECEPTACLE REQUIRED, RATED AT 15 AMP MINIMUM, TO RECEIVE 3-WIRE PARALLEL BLADE GROUNDING TYPE MALE PLUG. PROVIDE CHROME SUPPLY STOP AND P-TRAP. SEE MANUFACTURER'S INSTRUCTIONS FOR PROPER INSTALLATION PER ACCESSIBILITY REQUIREMENTS. GLASS FILLER IS TO BE INSTALLED ON THE HIGH FOUNTAIN. NEW WASTE OR SAN. SEWER EXISTING WASTE OR SAN. SEWER CONDENSATE DRAIN D m m .. GAS NEW VENT EXISTING VENT - NEW COLD WATER EXISTING COLD WATER - NEW HOT WATER - - EXISTING HOT WATER - PIPE DROP - PIPE RISE o -o- FLOOR CLEAN -OUT WALL CLEAN -OUT e FLOOR DRAIN t5 VENT THRU ROOF POINT OF CONNECTION -...--S- 0 WATER METER SHUT-OFF VALVE 2 -id- Q CONCEALED SPRINKLER HEAD ® RECESSED PENDANT SPRINKLER HEAD ® UPRIGHT SPRINKLER HEAD BRASS FINISH ® PENDANT SPRINKLER HEAD BRASS FINISH E EXISTING SPRINKLER HEAD Fe PORTABLE FIRE EXTINGUISHER FINISH: CONCEALED AND RECESSED PENDANT HEADS WHITE UNLESS OTHERWISE NOTED B: BLACK C: CHROME LEGEND AND SYMBOLS REMARKS FIAT MOP MOLDED STONE SERVICE BASIN MODEL NO. MSB-2424 WITH VINYL BUMPERGUARD. FURNISH WITH AMERICAN STANDARD FAUCET MODEL NO. 8344.112 WITH INTEGRAL VACUUM BREAKER AND STOPS. PROVIDE 42" RUBBER HOSE WITH FAUCET. WALL CLEANOUT FLOOR CLEANOUT CLEANOUT BREAK SINK THERMOSTATIC MIXING VALVE Y" 2" 2" 1Y2" RHEEM WATER HEATER MODEL NO. EGSP-6, 6 GALLON, 208V-10-60, 3 KW AND 14.4 AMPS. ACCESSIBLE TYPE ACCESSIBLE TYPE ACCESSIBLE TYPE PRECISION PLUMBING PRODUCTS TRAP PRIMER, MODEL NO. P-2, COPPER BODY, ADJUSTABLE WITH Y2" COPPER TYPE "L" TO FLOOR DRAIN. ZURN FLOOR DRAIN MODEL NO. Z-415-6B, CAST IRON BODY, COMBINATION INVERTIBLE CLAMP AND ADJUSTABLE COLLAR, ,2" BOTTOM OUTLET WITH 6" ROUND NICKEL BRONZE STRAINER. ZURN ZN-1446-BP CLEANOUT TEE, DURA-COATED CAST IRON BODY, GAS AND WATER TIGHT BRONZE PLUG AND STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. ZURN FLOOR CLEANOUT MODEL NO. ZN-1400 WITH GAS -TIGHT AND WATER -TIGHT TAPERED THREADED PLUG AND ROUND POLISHED NICKEL BRONZE SCORIATED ADJUSTABLE TOP. WITH DEEP SEAL P-TRAP NTS OON-P0101-DOO-LGND D 09/03/13 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT PLUMBING PLAN CHECK DIVISION AND THAT DIVISION'S STAMPED APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ALL TRADES INCLUDED BUT NOT LIMITED TO ELECTRICAL FIRE PROTECTION, MECHANICAL AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. CONTRACTOR SHALL PROVIDE CUT SHEETS TO LSD&C FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 6. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY THE EXACT LOCATIONS, SIZES, INVERTS AND CONDITION OF EXISTING SANITARY WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND DOMESTIC COLD WATER SUPPLY PIPING TO TENANT'S DEMISED PREMISES PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND/OR FAILURE TO PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. 7. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE/MAINTENANCE EASE. 8. THE CONTRACTOR SHALL VERIFY WITH LOCAL CODES AS TO THE REQUIREMENT/INSTALLATION OF ANY "WATER SAVING" DEVICES TO THE PLUMBING FIXTURES. (EXAMPLE: TOILET, FAUCETS, ETC.). 9. PLUMBING SYSTEM SHALL BE PRESSURE TESTED AND STERILIZED PER LANDLORD'S CRITERIA AND LOCAL AUTHORITY. 10. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. withoutAko changes Man be the scsm of work m Io Tukwilapriorapproval of Building Division. NOTE: RrvisiOns will require a new plan su bnaal anJ m�.7 in;,lude additional plan review lees. ZURN CLEANOUT FERRULE WITH PLUG #Z1440 WITH DURA-COATED CAST IRON BODY, WITH GAS -TIGHT AND WATER -TIGHT ABS TAPERED THREADED PLUG. DAYTON D11719 SINGLE BOWL SINK (19" x 17" x 61fi" BOWL) WITH CHICAGO 350-VPPABCP MECHANICAL GOOSENECK FAUCET. SYMMONS MIXING VALVE #7-225-CK "MAXUNE", if INLETS AND OUTLET, THERMOSTATIC CONTROLLER WITH INTEGRAL CHECKS, ALL BRASS BODY WITH DUAL STAINLESS STEEL STRAINER, VANDAL -RESISTANT TEMPERATURE ADJUSTMENT HANDLE. SET TO 105'. MOUNT IN ACCESSIBLE LOCATION (TIGHT UNDER SINK IN LEAST VISIBLE LOCATION POSSIBLE). PLUMBING FIXTURE SCHEDULE-VS/PINK PLUMBING GENERAL NOTES ACCESSIBLE TYPE NTS 05N-P0101-E00-SCKD E 01/17/14 NTS OON-P0101-COO-NOTE C Oq/03/13 UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT, MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE PLUMBING WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS. 2. FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND COLD WATER SUPPLY PIPING ABOVE CEIUNG PRIOR TO COMMENCEMENT OF ANY WORK. AFTER INSTALLATION AND FINAL CONNECTION OF NEW WASTE PIPING BELOW SLAB, BACK FILL AND PATCH IN ACCORDANCE WITH THE LANDLORD'S CRITERIA REGARDING SUCH WORK. 3. CONTRACTOR SHALL FURNISH AND INSTALL ALL OF THE NECESSARY PLUMBING FIXTURES (SEE PLUMBING RESPONSIBILITY SCHEDULE ON THIS SHEET) TO SERVE THE TENANT'S DEMISED PREMISES AND MAKE NECESSARY INSTALLATION OF DOMESTIC WATER AND SEWER PIPING FROM TENANT'S DEMISED PREMISE TO CONNECTION PROVIDED BY LANDLORD. 4. SANITARY VENTS SHALL BE ROUTED TO THE EXISTING LANDLORD'S POINT OF CONNECTION WITHIN THE TENANT'S DEMISED PREMISES OR TO A POINT APPROVED BY LOCAL AUTHORITY. THE CONTRACTOR SHALL PROVIDE A CAPPED TEE FOR POSSIBLE FUTURE CONNECTION (IF REQUIRED BY THE LANDLORD). CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR, AS REQUIRED. VENT THRU ROOF SHALL BE AT LEAST 15 FEET AWAY FROM A/C UNIT FRESH AIR INTAKE. 5. SEAL AROUND ALL PIPES PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED FIRE SEAL MATERIAL ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE PERMITTED. 6. THE CONTRACTOR SHALL INSTALL ALL TOILET FIXTURES IN ACCORDANCE WITH ALL CODES AND AS REQUIRED BY LANDLORD'S CRITERIA. CONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE WATER CLOSET AND NO MORE THAN 44" A.F.F. 7. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT'S DEMISED PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO OTHER TENANTS AND/OR TO THE BUILDING. FAILURE TO DO SO SHALL BE AT THE RISK AND SOLE EXPENSE OF THE CONTRACTOR. 8. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S LABORATORIES AND UNION LABELS WHERE SUCH LABELING APPLIES. 9. PLUMBING CONTRACTOR TO FIELD VERIFY PROPER SLOPE OF EXISTING SEWER TO MAIN SEWER PRIOR TO ANY NEW PLUMBING INSTALLATION. 10. PLUMBING CONTRACTOR MUST VISIT THE JOBSITE TO BECOME FAMIUAR WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS AND OTHER EXISTING JOB CONDITIONS THAT MAY AFFECT THE WORK. ADDITIONALLY, PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS WASTE, VENTS, WATER ONES, ETC. 11. PLUMBING CONTRACTOR TO FAMILIARIZE AND FOLLOW SPECIFICATIONS AND DETAILS CONTAINED IN DESIGN CRITERIA OF TENANT HANDBOOK. 12. PLUMBING CONTRACTOR TO CLEAR AU. EXISTING AND NEW DRAIN LINES AND FIXTURES, PRIOR TO TURNING OVER SPACE TO TENANT. 13. PLUMBING CONTRACTOR SHALL PROVIDE ACCESS TO VALVES, TRAP PRIMERS, ETC. INSTALLED BEHIND WALLS, FLOORS OR CEILINGS. 14. NO PVC PLASTIC PIPING ALLOWED WITHIN CEILING VOIDS USED FOR NON -DUCTED RETURN AIR PLENUM OR IN WALLS, EXCEPT IN CANADA WHERE XFR-PVC MAY BE USED IF PERMITTED BY THE AUTHORITY HAVING JURISDICTION. 15. THE GENERAL CONTRACTOR'S FIRE SPRINKLER SUB -CONTRACTOR SHALL DESIGN AND INSTALL FIRE SPRINKLER SYSTEM CONFORMING TO LANDLORD'S CRITERIA, TENANT'S REQUIREMENTS, AND PER LOCAL CODES AND NFPA STANDARDS. FILE COPY Permit No. P 11: SQ Plan review approval is subject to wore and anissices. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and is acknowledged: Date: Cn/i1-) City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: t+(Mechanlcat PrElectrical Q Plumbing cawns Piping ;< cf Tukwila E.12: s DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 17 2014 bt- City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 10 2014 PERMIT CENTER PROJECT INFORMATION: CoNs.c.1....RcA`1" I i 2oG2. Valley View St. Suite 2258 Gd .:Uen:.Grove, CA. 92845 Phone: 714-892-81 57 Fax: 714-884-7294 0 176 rr Er ET) LU 0 cc LU CO 3 0 0 tec ay 0 E 0 0 0 q3 cJ Lao ® w CO c 0 w R, c 00 ® uj gx 00 w 07) Z z (7) o LIJ wic V=O� Immo 1- �y� 53 51 J J I REVISIONS: DAM DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 5/16/14 CH STAFF HHH PLUMBING � - NOTES AND SCHEDULES PLUMBING CONSTRUCTION NOTES NTS CON-P0101-AOO-NOTE A 0c1/03/13 L� DRAWING NUMBER: O O F� '3 F' '4 TEB T 'E A _Ii1_ 11 FR ALCOVE i SECONDAfiY CLOSET VESTIBUL � I � MAIN 1 t 1 �E C - � VESTIBULE ... , R � TR #9 �1 iii 0 \— TR #10 0 0 5P O MEM MIN MIN 1111111 0 0 0 ROOM #7 BEAUTY 0 0 O 0 O TR #8 0B IG WI 0 0 QUEUING ZONE OB TR #12 B SHWRAP o ROOM O O 0 0 0 O O 0 O O ROOM #6 BRA SALON 0 0 O 0 0 0 H 0 ADJACENT TENANT - N.I.C. 0 0 0 O 0 ROOM #2 VSL 1A 5P 0 ADJACENT TENANT - N.I.C. "VERIFY ALL FIELD CONDITION RIOR TO BID" 44, 1 J VSL DISPLAY WINDOW #1 TR #1 MALL CONCOURSE FIRE PROTECTION CONTRACTOR TO VERIFY IF SPRINKLER HEADS IN STOREFRONT AND TRANSITIONS ARE REQUIRED BY THE CODE, LOCAL AUTHORITIES, FIRE MARSHALL AND THE LANDLORD. ELIMINATE IF NOT REQUIRED VSL DISPLAY WINDOW #2 (16 W9 14 RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER 0 CONNECT (N) 4" SANITARY SEWER BELOW SLAB TO (E) SANITARY SEWER LINE. (FIELD VERIFY EXACT SIZE AND LOCATION — MIN. 4") O2 CONNECT (N) 1" COLD WATER TO (E) COLD WATER UNE. (FIELD VERIFY EXACT SIZE AND LOCATION — MIN. 1") O3 P.O.C. OF (N) VENT TO (E) VENT UNE. (FIELD VERIFY EXACT SIZE AND LOCATION — MIN. 1h") ® 1" PRIMARY CONDENSATE DRAIN FROM EQUIPMENT TO DISCHARGE TO TAILPIECE OF LAVATORY, SLOPE 113" PER FOOT. PROVIDE CONDENSATE DRAIN PUMP IF REQUIRED (FIELD VERIFY) 0 1" SECONDARY CONDENSATE DRAIN FROM EQUIPMENT TO DISCHARGE AT CEILING ABOVE 'MENS' LAVATORY, SLOPE ifi" PER FOOT. PROVIDE CONDENSATE DRAIN PUMP IF REQUIRED (FIELD VERIFY) PLUMBING CONTRACTOR TO PROVIDE WATER METER — 'HERSEY MODEL NO. %" MVR' AT MINIMUM OF 16 GPM. VERIFY LOCATION. MOUNT 48" ABOVE FINISHED FLOOR. MAKE NECESSARY CONNECTIONS AS REQUIRED. METER TO READ IN GALLONS. 7O METAL LINER CONDITION — INSTALL CONCEALED SPRINKLER HEAD IN PRE—CUT HOLE IN PANEL FIRE PROTECTION CONTRACTOR SHALL ENSURE THAT CONCEALED HEAD COVER COMPLETELY COVERS 2-5/8" PRE —DRILLED HOLE. ft-- 0078 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 17 2014 City of Tukwila BUILDING DIVISION GC TO PROVIDE WRITTEN REPORT TO LSD&C PM ON CONDITION OF EXISTING SEWER TIE—IN REGARDING SLOPE AND FLOW. • SCOPE WITH CAMERA PRIOR TO CONNECTION • DO NOT CONNECT WITHOUT LSD&C PM AUTHORIZATION IF SPECS NOT MET NOTE: REFER TO SPECIFICATION BOOKLET FOR ADDITIONAL INFORMATION. 1.20G2. Valley View St. Suite 2259 Garden: Grove, CA. 82845. Phone: 714-882-S1.57 Fax: 714-884-7284 01 /02/15 cli o Lu 0 Er co esa ao ao ao rn IIs q 9 PROJECT INFORMATION: w U w CO Calme 0 U - J CC W HLJ Zz w Q C)=o3 - I— o n COMc°nl- DATE: May 28, 2014 Three Limited Par Lai LL N 0 N N Quo 0 N J J L W a0 '0 CE W Z U t7� Ov o V) o REVISIONS: DATE DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 5/16/14 STAFF STAFF HHH PLUMBING AND FIRE SPRINKLER HEAD PLAN DRAWING NUMBER: PLUMBING AND FIRE SPRINKLER HEAD PLAN 1/4" = 1'-0" A L� EXTERIOR LEADING DOCK PLUMBING AND FIRE SPRINKLER HEAD PLAN TM LAV- HALLWAY ADJACENT TENANT - N.I.C. DO NOT ROUTE ANY PIPING OVER ELECTRICAL EQUIPMENT E R CTICA ARA —II I> EN'S ADJACENT TENANT - N.I.C. BR AK R•OM OFFICE VESTIBULE 3 PERSON MANAGERS OFFICE AFR *1 TYPE C (77P.3) 0 0 0 2 4 PE D T T 'EA P03.01 FR TR *11 ALCOVE 0 ROOM *7 BEAUTY 0 = LU Ot CONNECT (N) 4" SANITARY SEWER BELOW SLAB TO () Z (E) SANITARY SEWER LINE. (FIELD VERIFY EXACT SIZE AND LOCATION - MIN. 4") ® CONNECT (N) 1" COLD WATER TO (E) COLD WATER LINE. (FIELD VERIFY EXACT SIZE AND LOCATION - MIN. 1") ® P.O.C. OF (N) VENT TO (E) VENT LINE. (FIELD VERIFY EXACT SIZE AND LOCATION - MIN. th") ® 1" PRIMARY CONDENSATE DRAIN FROM EQUIPMENT TO DISCHARGE TO TAILPIECE OF LAVATORY, SLOPE A" PER FOOT. PROVIDE CONDENSATE DRAIN PUMP IF REQUIRED (FIELD VERIFY) 5® 1" SECONDARY CONDENSATE DRAIN FROM EQUIPMENT TO DISCHARGE AT CEILING ABOVE 'MENS' LAVATORY, SLOPE Ya" PER FOOT. PROVIDE CONDENSATE DRAIN PUMP IF REQUIRED (FIELD VERIFY) O PLUMBING CONTRACTOR TO PROVIDE WATER METER - 'HERSEY MODEL NO. %" MVR' AT MINIMUM OF 16 GPM. VERIFY LOCATION. MOUNT 48" ABOVE FINISHED FLOOR. MAKE NECESSARY CONNECTIONS AS REQUIRED. METER TO READ IN GALLONS. 10 METAL LINER CONDITION - INSTALL CONCEALED SPRINKLER HEAD IN PRE-CUT HOLE IN PANEL. FIRE PROTECTION CONTRACTOR SHALL ENSURE THAT CONCEALED HEAD COVER COMPLETELY COVERS 2-5/8" PRE -DRILLED HOLE. SECONDA�Y VESTIBUL MAIN VESTIBULE TR #9 QUEUING ZONE O 0e CASHWRAP 0 ROOM REVIEWED FOR ODE COMPLIANCE APPROVED JUN 17 2014 City of Tukwila BUILDING DIVISION GC TO PROVIDE WRITTEN REPORT TO LSD&C PM ON CONDITION OF EXISTING SEWER TIE-IN REGARDING SLOPE AND FLOW. • SCOPE WITH CAMERA PRIOR TO CONNECTION • DO NOT CONNECT WITHOUT LSD&C PM AUTHORIZATION IF SPECS NOT MET NOTE: REFER TO SPECIFICATION BOOKLET FOR ADDITIONAL INFORMATION. RECEIVED CITY OF TUKWILA JUN 10 2014 PERMIT CENTER 1.2062. Valley- View- St. Suite 2258 .Gd,,.ien::Grove. CA. 92845 Phone: 71.4-893-61.57 Fax: 714-B94-7224 DATE: May 28, 2014 01/02/15 0 0 tic 0 V LU CO co � � J J Q c 0o ® W ix 00 00 Zz ° o W Q --- (I)9.1i) > c`01) 0 0_ REVISIONS: 4,0 LL 0 0 Lt3 0 DATE ISSUED: 5/16/ 14 DESIGNED BY: CH DRAWN BY: STAFF CHECKED BY: HHH PLUMBING AND FIRE SPRINKLER HEAD PLAN DRAWING NUMBER: WASTE & VENT PIPING DIAGRAM TMV LAV-2 (TYP.2) 5/4° c`ii 3/ °1' MS NOTE: 1 PROVIDE AN APPROVED BACKFLOW PREVENTER FOR MAIN DOMESTIC WATER LINE, IN ACCORDANCE WITH LOCAL CODE AND LANDLORD REQUIREMENTS. DOMESTIC WATER PIPING DIAGRAM DF-1 /4" J NC —I (TYP.2) 1 TP FD (TYP.2) � I � I � G� i I Y� P03.01 DREAMSTEAMERS (SY OTHERS) Y" L. SK I NTS c Oci/25/12 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 102014 PERMIT CENTER NTS A O 1/25/12 A T.:1 E N. N e 1 Nlzino.,. 12O62 Valley View St. Suite 2258 Garden Grove. CA. 22845. Phone: 714-992-E 1. b./ Fax: 714-924-7294 NMI PROJECT INFORMATION: z 0 0g D Z Lu • w O Er 06 • co • 411 01102115 ......................... J -J a in 2 DATE May 28, 2014 0 00 ui CI 0 0 ro 0 4, D u) W LJ N o N N Q "Kt o Q• vN O M 0 N -J J la w g °Zo 0 M 0 W 0 Ct 0 J LJ- REVISIONS: DATE DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 5/16/14 EG STAFF HHH PLUMBING ISOMETRICS 0 DRAWING NUMBER: NOTE: POWER AND WATER TO BE LOCATED WHERE MOST ACCESSIBLE, BASED ON DETAIL TURN DOWN INTO STACK C0..NSOLAIDATE.0 E N' 1 N e`"fi 1 1 PORTAL SPRINKLER HEAD LOCATION NOTES: 1. SPACE PENDANT SPRINKLER HEADS PER NFPA REQUIREMENTS. MOUNT PENDANT SPRINKLER NEAR CENTER WITHIN CAVITY. 2. FIRE SPRINKLER CONTRACTOR TO CONFIRM HEAD TYPE, DENSITY OF COVERAGE, AND SPACING WITH AUTHORITY HAVING JURISDICTION. SEMI -RECESSED FIRE SPRINKLER HEAD CONCEALED FIRE SPRINKLER HEAD - CHROME OR BLACK. REFER TO PLAN VERTICAL SECTION AT VS ENTRY NTS 05D-P0301-R00-VSVS R O /03/201 TYPICAL SPRINKLER HEAD LOCATION FOR T-BAR CEILING TYPICAL 24"X24" CEILI G TILE 2' 0" TYPICAL 48"X12" CEILING TILE �J TYPICAL SPRINKLER HEAD LOCATION FOR T-BAR CEIUNG TYPICAL 48"X24" CEILING TILE (FAUX 24"X24") FIRE SPRINKLER HEAD LOCATION DETAILS NOT LESS THAN 1 18" FROM CO THE TOP OF ANY OBSTRUCTION RECESSED HEAD DROP NIPPLE REDUCER SUSPENDED CEILING ESCUTCHEON SPRINKLER HEAD DROP NIPPLE REDUCER SPRINKLER HEAD PENDANT HEAD 1" = 1'-0" OOD-P0301-POO-FSHL r ■ i DROP NIPPLE REDUCER P 0'R/03/201 SPRINKLER HEAD SUSPENDED CEILING REFER TO PLAN AND LEGEND FOR POP -OUT CONCEALED COVER FINISH COLOR. , t HEAD SPRINKLER HEAD UPRIGHT HEAD NTS HANGERS (MUST BE WITHIN 6" OF DROP) 1/2" TYPE "L" WATER SUPPLY, CLAMP TO WALL AT TOP, MIDPOINT AND BOTTOM. (DO NOT RUN PIPE INSIDE WALL) FLOOR DRAIN DREAM - STEAMER �- CW MAIN JOIST/BEAM Y2" TYPE "L" SUPPLY 4 4 4 1 1 4 1 4 1 4 4 I 1 1:4 pt it / CEILING WALL 1/2" TYPE "L" DRAIN DOWN TO FLOOR DRAIN. TERMINATE 1" ABOVE FLOOR DRAIN WATTS SERIES "9DM3" DOUBLE CHECK BACKFLOW PREVENTER WITH VENT PROVIDE A 3/8" BALL VALVE ON WALL FINISHED FLOOR INSTALL 3/8" X 72" FLEXIBLE BRAIDED TUBING FURNISHED WITH DREAMSTEAMER SECTION VIEW WALL RECEPTACLE (SEE ELECTRICAL DWGS.) FACTORY POWER CORD WITH PLUG 01' 48" RUN HOSE FROM BASE OF FIXTURE TO FLOOR DRAIN (HOSE BY GC) 1/2" C.W. SUPPLY 3/8" BRAIDED FLEXIBLE TUBING FLOOR DRAIN PLAN VIEW DREAMSTEAMER DETAIL PROVIDE CLEANOUTS IN TURNS/ENDS OF PIPE. USE DWV FITTINGS IF SIZE IS LARGER THAN 1" SLOPE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE MAKE CONNECTION TO EQUIPMENT AS REQUIRED MAKE PIPE MINIMUM ONE SIZE LARGER THAN EQUIPMENT CONNECTION, MINIMUM 3j". USE TYPE "M" HARD COPPER UP TO 1" AND TYPE DWV FOR LARGER DISCHARGE INTO CENTER HOLE OF GRATE OF WASTE RECEPTACLE WITH AIR GAP SUFFICIENT TO REMOVE GRATE AND STRAINER. MINIMUM GAP = TWO PIPE DIAMETERS VERIFY WITH LOCAL CODES IF/WHEN TRAP AND/OR VENT ARE REQUIRED FOR THE LENGTH OF DRAIN PIPE INSTALLED ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS REQUIRED. REFER TO LOCAL CODES FOR FURTHER INFORMATION. CONDENSATE DRAIN DETAIL NTS OOD-P0301-K01-COND CEILING DISCHARGE WATER LINE FROM SECONDARY CONDENSATE LINE OF AC UNIT THRU OPENING IN CEILING (ABOVE SINK) SLOPE DISCHARGE WATER LINE FROM /--- PRIMARY CONDENSATE LINE OF AC UNIT TO TAILPIECE OF SINK SLOPE SINK PROVIDE ESCUTCH PLATE AT WALL CONDENSATE DRAIN DISCHARGE DETAIL K 08/06/11 CONDENSATE DRAIN TO SLOPE DOWN TO TAILPIECE OF SINK/OR APPROVED RECEPTOR (REFER TO PLANS) VENTED PERFORATED CAP 3" MIN. SLOPE 3" MIN. CEILING UNION SLOPE FC, AHU, OR WSHP 1" CLEARANCE ALL AROUND SECONDARY CONDENSATE SECONDARY GALVANIZED DRAIN TO SLOPE DOWN TO DRAIN PAN CEILING ABOVE SINK/FLOOR SINK. TRAP FOR WATER SEAL 2" HIGH ROOFING MATERIALS (FLASHING, ETC.) PER LANDLORD REQUIREMENTS 3"IAIN INCREASER WHERE REQUIRED latkalattkEERMaidiktggggEL ROOFING MATERIAL ROOF CONSTRUCTION SLEEVE ROOF CONSTRUCTION AS REQUIRED VENT STACK NTS 05D-P0301-H00-DRST d. FLOOR SLAB / / / / / / j C CAULK WITH FLEXIBLE FILLER SLEEVE NON-COMBUSTIBLE UL LISTED FIRE STOPPING PIPE NOTE: ALL FLOOR PENETRATIONS MUST BE SLEEVED AND LIQUID TIGHT. PIPE FLOOR PENETRATION DETAIL NTS OOD-P0301-G00-PPEN G OGI/03/201 TRAP PRIMER WITH INTEGRAL VACUUM BREAKER PROVIDE COUPLING TYPE "K" SOFT COPPER TUBE BELOW FLOOR SLAB WITHOUT JOINTS. SLOPE TOWARD FLOOR DRAIN TRAP. PROVIDE ELASTOMERIC INSULATION FROM TRAP TO ABOVE FLOOR SLAB DOMESTIC COLD WATER LINE IN PLUMBING CHASE OR UNDER FIXTURE. MAKE BRANCH TO TRAP PRIMER OFF TOP OF THIS PIPE TRAP PRIMER IN CHASE OR UNDER FIXTURE. INSTALL PRIMER MINIMUM SIX INCHES ABOVE FLOOD RIM OF FIXTURE BEING SERVED PROVIDE DISTRIBUTION UNITS WHERE MORE THAN ONE TRAP IS SERVED BY A PRIMER PRIMER MAY BE LOCATED ABOVE CEILING WHERE ACCESSIBLE. IF LOCATED IN A CHASE OR WALL, PROVIDE A HINGED, LOCKABLE, PRIME COATED ACCESS DOOR IN AN ACCESSIBLE BUT INCONSPICUOUS PLACE da � CONCRETE FLOOR FLOOR DRAIN OR FLOOR SINK P-TRAP WITH TRAP PRIMER CONNECTION TRAP PRIMER MAY BE LOCATED ABOVE CEILING WHERE ACCESSIBLE. TRAP PRIMER CLEANOUT PLUG FINISHED FLOOR CONCRETE SLAB COVER ADJUSTABLE HOUSING STRUCTURE AT UPPER LEVEL SEALANT 1,4 40 /, TO TENANT'S SANITARY SEWER \� ///// ®FLOOR la .4 /\Y\\\/N > GRADE AT LOWER LEVEL 1" = 1'-0" OOD-P0301-F01-TRAP O�. ®WALL WALL CLEANOUT WALL ACCESS COVER WALL VENT THRU ROOF DETAIL UNINSULATED - UL SYSTEM WL 1001 RATED WALL 1" FIBERGLASS INSULATION THRU WALL ONLY (E) OR (N) PIPE 3M BRAND FIRE BARRIER CP25WB+ CAULK OR EQUAL COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE AND WALL AND LEAVE A MIN. %" BEAD AROUND BOTH OUTSIDE FACES OF WALL NOTE: 1-1/2":1'-0" OOD-P0301-DOO-VTR D 09/03/201 INSULATED - UL SYSTEM WL 5030 INSTALLATION TO FOLLOW UL SYSTEM WL 1001 OR WL 5039 AND BE A UL TESTED ASSEMBLY. PIPE THRU FIRE WALL PENETRATION DETAIL COLD WATER SUPPLY TO WATER HEATER CW —I -2 %"2- CW PIPE HANGER NEXT TO PIPE TEE BUTYL DIAPHRAGM AIR CHARGING VALVE FILL TANK WITH AIR PRESSURE - THEN OPEN VALVE WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING GATE/BALL VALVE BY PC (TYP) 3/4" T & P RELIEF VALVE BY PC RUN 3" COPPER PIPE TO MOP SINK DRAIN VALVE BY PC NTS OOD-P0301-COO-PTFW " VACUUM BREAKER cr BY PC HW —j UNION BY PC (TYP) 114: -"\— EXPANSION TANK INSTALLATION SHALL OCCUR ONLY WHEN THERE IS A BACKFLOW PREVENTION DEVICE INSTALLED WITHIN THE TENANT SPACE, WATER SYSTEM, BUILDING WATER SYSTEM OR OTHERWISE REQUIRED BY CODE. l WATER HEATER, SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. PLATFORM BY GENERAL CONTRACTOR 1" SECONDARY DRAIN REFER TO STRUCTURAL DRAWINGS FOR SEISMIC SUPPORT REQUIREMENTS DRAINS TO MOP SINK GALV. DRIP PAN BY PC NOTE: INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. WATER HEATER DETAIL FINISHED FLOOR SEALANT WATERPROOF MEMBRANE SHALL EXTENT INTO THE DRAIN BOWL FLANGE. PC SHALL CLAMP PAN WATER TIGHT INTO DRAIN COLLAR STRUCTURE AT UPPER LEVEL TO TRAP PRIMER (SEE RISER DIAGRAMS) 1" = 1'-0" OOD-P0301-BOO-WTHR CONCRETE SLAB OR FINISHED FLOOR / I GRADE AT LOWER LEVE REVIEWED FOR CODE COMPLIANCE APPROVED JUN 17 2014 City of Tukwila _BUILDING DIVISION TO TENANT'S SANITARY SEWER //— MIN. 4" DEEP SEAL TRAP 11+ 00 V6 - • RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER 12062. Valley. View St- Suite 2258 .Garden::Grove. CA. 92845 Phone: '714-893-61.57 Fax: 714-894- /84 a ) 0 b 176 Z ei LU a CC co CO 0 LU LU 0 Er DATE: May 28, 2014 PROJECT INFORMATION: Fun LU cc LU Cf) a � J 00 ® L!J ce 00 I—w zz ® w 11112C1 V=o� t` w t!1 W U V)M(nl=— REVISIONS: EWE DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 5/16/14 CH STAFF HHH PLUMBING AND FIRE PROTECTION DETAILS FIRE SPRINKLER HEAD DETAILS NTS OOD-P0301-NOo-FSHD N 02/14/201 CONDENSATE DRAIN DETAIL NTS J 08/08/11 CLEANOUT DETAILS NTS OOD-P0301-E00-FWCO E 09/03/201 FLOOR DRAIN DETAIL NTS OOD-P0301-A00-FDRN A 09/03/201 L� DRAWING NUMBER: