HomeMy WebLinkAboutPermit PG14-0140 - THORNTON RESIDENCE - WATER HEATERTHORNTON RESIDENCE
3219 S 142 PL
PG14-0140
CITY OF TUKWILA
Community Development Department
6300 Southcenter Boulevard, Suite 100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
http://www.TukwilaWA.gov
PLUMBING - GAS PIPING PERMIT
Parcel No.: 941500-0070
Address: 3219 S 142 Place
Project Name: Thornton Residence
Permit Number: PG14-0140
Issue Date: 09/10/14
Permit Expires On: 03/12/01
Owner:
Name: Jerry Thornton
Address: 3219 S 142 PI Tukwila, WA 98168
Contact Person:
Name: Carol Randall Phone: (425) 636-7054
Address: 11715 N Creek Pkwv S, Ste C-106 Bothell, WA 98011
Contractor:
Name: Fast Water Heater Company Phone: (425) 814-8381
Address: 11715 N Creek Pkwy S, C-106 Bothell, WA 98011
License No.: FASTWWH948BC
Lender:
Name: N/A
Expiration Date: 01/04/16
Phone:
Address:
Description of Work:
remove/replace water heater
Valuation of single family: $1,057.00
Valuation mf/comm: $ 0.00
Type of Work: residential
Fees Collected: $ 48.83
Electrical Service Provided by: Seattle City Light
Water District:
Sewer District:
Current Codes adopted by the City of Tukwila
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2102
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Permit Center Authorized Signature: /
AkNA ,LyietV
Date:
01,1/0
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provision of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of works I am authorized to sign and obtain this development permit and agree to the
conditions attached to this p mit.
Signature: _��i Date:
/7.
Print Name: %31.19! ,fr20
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance , or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1. No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division.
2. All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector.
3. All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code.
4. No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
5. All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall
be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work
will stand the test prescribed before giving notification that the work is ready for inspection.
6. No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is
made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to
minimum R-3.
7. Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel
nail plates not less than 18 guage.
8. Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be
directly embedded in concrete or masonry.
9. All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the
requirements of the building code.
10. Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above
the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris.
11. The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any
violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction.
12. The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
13. All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all
residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply
with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2012 Uniform
Plumbing Code Section 402 of Washington State Amendments.
14. VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation
of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to
violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit
based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the
construction documents and other data.
PERMIT INSPECTIONS REQUIRED:
Permit Inspection Line: (206)438-9350
8004 Ground work
8005 Rough -in plumbing
9001 Underground
9002 Rough -in gas piping
1900 Plumbing Final
2000 Gas Piping Final
CITY OF TUKWILA
Community Development G„zpartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
Plumbing/Gas Pt it No. C ` f 1 wn
Project No
{For office use anly)
712942
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address:
Tenant Name:
3219 S 142 PL
King Co Assessor's Tax No.: 9415000070
Suite Number: Floor:
New Tenant: (] .... Yes E ..No
THORNTON, JERRY & DASLENE
Property Owners Name:
THORNTON, JERRY & DASLENE
Mailing Address:
PIF-DONE
City
State
Zip
•
CONTACT PERSON -Who do we contact when your permit is ready to be issued
Day Telephone: 425-636-7054
Name:
Mailing Address:
Carol Randall @ Fast Water Heater
City
State
Zip
E-Mail Address: Fax Number:
PLIJNIII NG / GAS PIPING CONTRACTOR1NFORMATION
Company Name: FAST WATER HEATER COMPANY
Mailing Address: 11715 N. CREEK PKY. S., SUITE C-1(
BOTHELL, WA 98011
City Stale Zip
Contact Person: goi 1 v Day Telephone: 425-636-70''Li
E-Mail Address: '4 t (M "CS C DfU& t yvtti-rty mot 4-cab m Fax Number: 425-636-7C gr'2
FASTWWH948BC Expiration Date: 1/4/20I'0
Contractor Registration Number: p
ARCffiTECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
City
State
Zip
Contact Person: Day Telephone:
E-Mail Address: Fax Number:
ENGINEER 4F. RECORD All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E-Mail Address: Fax Number:
State
Zip
Page 1 of 2
Valuation of Project (contractor's bid price): $ I k�
Scope of Work (please provide detailed information): Remove/Replace Gas Water Heater
Building Use (per Intl Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type: •
Qty .
Future; Type:
TXp
Qty
Fixture T e
Type;
Qty
P'ixturc.Type
QtY.
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
1
Additional medical gas
inlets/outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific gas
PERMIT. APPLIC
ATION --.
• Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days, The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTEIQRIZED AGENT:
Signature:
Print Name:
'V6 1 S y-) dt
Mailing Address: 11715 N. CREEK PKY. S., SUITE C-106
Date: 9/3/14
Day Telephone: 425-636-7 DZ'
BOTHELL, WA 98011
City State
Zip
Date Application Accepted:
io I Li
Date Application Expires:
Q:WpplicatiansWFonns•Appliendons On Llne1.3•2006 - Plumbing -Gas Piping Permit Appiication.doc
Revised: 4.2006
bh
Staff Initials:
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT QUANTITY
PermitTRAK
PAID
$48.83
PG14-0140 Address: 3219 S 142ND PL Apn: 9415000070 $48.83
PLUMBING $46.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
WATER HEATER FIXTURE FEE
R000.322.103.00.00
0.00
$14.00
TECHNOLOGY FEE $2.33
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3008
R000.322.900.04.00
0.00
$2.33
$48.83
Date Paid: Wednesday, September 10, 2014
Paid By: FAST WATER HEATER COMPANY
Pay Method: CHECK 17655
Printed: Tuesday, September 16, 2014 1:19 AM 1 of 1
SYSTEMS
CITY FORM NO 1 1912 ADOPTED BY DIVISION OF MUNICIPAL CORPORATIONS.
Received of
CITY OF TUKWILA
TREASURER'S RECEIPT
Date fAfrk 1 i' vV 1
FOR
, 20
N2 47838
ottio
\IT 000.,41.i00.00.0,0
0(2 AZT .11 o{ - 01°
BY
OLYMPIC PRINTER$, INQ.
DEPT:
TOTAL
Dollars,
WHITE - Finance Dept. CANARY - Customer PINK - File
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project: _ .%
IA 1 /' 1 �jt!' ,2.eS
Cam-
o
Type Inspection:
- I v M 13 • '! (.. , tU " L
Address:7t 9 l 4 ?—J
i-
Dat;k,) o(04"1 .1--A
Special Instructions: ��
04,r e.�
}-r-
ii) f / /
�
Date Wanted - �� — 14 < a.m.
:
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
0 147ritiCtre70
- 0
P_JP
.�.
1
1
Z
,21F
_...,
(
T
Inspes:tor:
0,A441t
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: 2 4 _ 14
FAST WATER HEATER COMPAI`
Page 1 of 6
Washington State Department of
Labor & !Industries
FAST WATER HEATER COMPANY
Owner or tradesperson
JORDAN, JEFFERY DAVID
Principals
JORDAN, JEFFERY
DAVID, PARTNER/MEMBER
HANLEYBROWN,
JASON, PARTNER/MEMBER
Doing business as
FAST WATER HEATER COMPANY
WA UBI No.
602 564 544
Parent company
FWH ACQUISITION COMPANY LLC
11715 N CREEK PARKWAY S, C-106
BOTHELL, WA98011
425-814-8381
KING County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
FASTWWH948BC
Effective — expiration
01/03/2006— 01/04/2016
Bond
DEVELOPERS SURETY & INDEM CO
Bond account no.
549792C
Received by L&I
01/03/2006
Insurance
American States Insurance Co
Policy no.
01C155607620
$12,000.00
Effective date
01 /01 /2005
Expiration date
Until Canceled
$1,000,000.00
Received by L&I
Effective date
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602564544&LIC=FASTWWH948BC&SAW= 09/10/2014