Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG14-0156 - TOP POT DOUGHNUTS - WATER, GAS AND EXHAUST FLUE
TOP POT DOUGHNUTS 401 BAKER BLVD PG14-0156 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 0223100085 PLUMBING/GAS PIPING PERMIT Permit Number: PG14-0156 Address: 401 BAKER BLVD Issue Date: 10/27/2014 Permit Expires On: 4/25/2015 Project Name: TOP POT DOUGHNUTS Owner: Name: PEARL ALVIN S+CAROLE R Address: 405 BAKER BLVD , SEATTLE, WA, 98188 Contact Person: Name: RICK PHILLIPS Phone: (206) 849-7453 Address: 234 FIFTH AVE S, EDMONDS, WA, 98020 Contractor: Name: WCI PLUMBING LLC Phone: (425) 774-4185 Address: 234 FIFTH AVE S , EDMONDS, WA, 98020 License No: WCIPLPL891R3 Expiration Date: 12/23/2015 Lender: Name: Address: , , , DESCRIPTION OF WORK: PROVIDE WATER, GAS AND EXHAUST FLUE FOR RACK STYLE POT AND PAN WASHER Valuation of Work: $5,000.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $203.13 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2014 2012 Permit Center Authorized Signature: Zae Date: V) I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: /©2? / rf This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING CITY OF TUKT T,A Community Developh__at Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/( s Permit No. Project No. Date Application Accepted: Date Application Expires: R-\0 (� (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: t-} 1 (j /a K l; R Q L V 0 Tenant Name: Me Po-1- Dov9htJu f' PROPERTY OWNER Name: 1p ear i r 1 ✓,,,, s 4. Ca t'o le R Address: Ho( ,Ct ®n i� xe r 64 i3O City: State: A Zip: CONTACT PERSON — person receiving all project communication Name: RicK Pkt11;pS Address: 341 5'4' Ave Scou4k City: Co► >vk c+Nd 5 State: w A Zip:R �D a Phone: Fax: .o (e) id (9- 7ys 3 Email: RICKWC; 4)ho�rna.l, Go inn King Co Assessor's Tax No.: Suite Number: Floor: J New Tenant: Yes ❑.. No PLUMBING CONTRACTOR INFORMATION Company Name: w c i Pl�,,,,,h;.N� Lac Address: ct 3 Y .S Atd e Sou-Lt-. City: Eol w►oiv()s State: liJq Zip;9620 Phone: Fax: `12S177y-y18S 412.5)774/-4/4.7 Contr Reg No.: w%1 pLPi.69/R 3 xp Date:1Z_23_ 20,5 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ �i, COO Scope of Work (please provide detailed information): fl o'd e 9ce5 dNd F hie 0 W JS4FBG rack Building Use (per Int'1 Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line \20I1 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures ani gas piping outlets being installed and the qua below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets I Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Disk Loa Sl,-.2r co, vvnnne 'LIG f PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: :: ie Date: /a'l(o—ly Print Name: R i' J Y N : / / " > Day Telephone: a 6) 8 6/ 9- 7 /3 3 Mailing Address: a 3 y A V i So va-t‘ d 0 A.C3 5 �� c18c7 City State Zip H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID 5` PG14-0156 Address: 401 BAKER BLVD Apn: 0223100085 $65.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R3697 R000.345.830.00.00 1.00 $65.00 $65.00 $65.00 Date Paid: Thursday, December 04, 2014 Paid By: WCI PLUMBING LLC Pay Method: CREDIT CARD 614072 Printed: Thursday, December 04, 2014 2:27 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS Y"Ci k+'.Zi" a'&'e'£q.s PermitTRAK r. .a.£";,-..,,, . .., I ACCOUNT QUANTITY PAID P„..k 14 015Address:41�BAKER,Bvf rLgIrNVr D'f =,- u,0.ka 2.310, 00y K ,-- Apn:.' 02 « it 0:o•r3s 13 GAS. $81.25 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $16.25 PLUMBING $121.88_ PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R3324 R000.322.103.00.00 0.00 $24.38 $203.13 Date Paid: Thursday, October 16, 2014 Paid By: RICK PHILLIPS MCI PLUMBING Pay Method: CREDIT CARD 216162 Printed: Thursday, October 16, 2014 10:26 AM 1 of 1 c�WSYSTEMS 0 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd„ #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 G114 -0/5e INSPECTION RECORD Retain a copy with permit PERMIT NO, Project: ---t7k)--r"\--- Type of Inspection: r--JAL. Address: 40 / & At'ke. e _ Date Called: SpeCial Instructions: Date Wanted: i 1 2 / j i LI ,...--s.m. -Pm, 'Requester:* <'.1 c V--- Phone No: ,a()C,e0 —5C s' 3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inskaor REINSPECTION FEE RE .G'Ib.IRED. Prior next inspection, fee must be t pa'cllat 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. 41 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: l C) ? ‘It5‘31-Ir Type of Inspection: , . (NlCI \A— I t.A...) 6A5 Address: HO c›-AKFE_ Date Called: A-)tluAkio ,.. Special Instructons; Date Wanted: ' (are p.rn. Requester: Phone No: jjApproved per applicable codes. Corrections required prior to approval. COMMENTS: ,--- '.") ... , --.. i----...,....., In stectcsr: Date* / 1/ 1.2! 1/4/ • REINSPECTION FEE REQUIRED. Prior to tiext inspection. fee must be paid/at 6300 Southrenter Blvd.! Suite 100. eau to schedule reinspection. FILE COPY Permit Nom 6)a$ C.,41ui+)o.iv car 3 - 6 V CFI4 Rez/uor CA Ad in €Q4erS y 54 e bin 5 .(4ceIs 97ps e iopede!‘) :17. 1:cni7,,,,d ro_es 3 di-c3 -40 sea +ke o kar4. LcLI' e. L1Qcc., Et,pfL.3 s h 0 44, 4 -rap :1G4 doo,jc'4s To 4-a/ 100-0) 0 A-) c rolf-u±-c. h eq4"- e_ 4 ; r 5 ; U.) ; 1/4 - 4-5 e +0 /1 af-i, (13 ie4:;' • +0 e .cor Pra' 5 Y.- 4-o L,Se 8 C F454.,,j), 4:2 i•J 6L 3 Cr? -Po 2 A.) dr i -.C• 3 6, cF^ At it, e kar 4- y 0,4.„, 4 r e colt:3(4i d 474- 3. 6 0 "J.91 ‘,1 3 ;2 i--- o 3 9 - 4- J' d '34-05 -C. 0 4-0 1,1v e -4-4)r 1-Ntoici4 1-7(54/ cF,h, p re, po 5 'r•-•? RE CODE CO PLIANCE APPROVED- t)Et o.c., 6-edd cceg i4 City ortukrala BUILDIN _ rvt rL, A, A IGS4- 2"-: IS P." RECEIVED CITY OF TUKWILA CORRECTION NOV 2 0 2014 LTR# PERMIT CENTER Y FUEL GAS PIPING TABLE 1216.2(4) SCHEDULE 40 METALLIC PIPE [NFPA 54-12: TABLE 6.2(e)]* GAS: NATURAL INLET PRESSURE20siti, PRESSURE DROP: 1.0 psi SPECIFIC GRAVITY: 0.60 PIPE SIZE (inch) NOMINAL: 1/2 % 1 11/2 11/2 2 21/2 3 4 ACTUAL ID: 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 LENGTH (feet) CAPACITY IN CUBIC FEET OF GAS PER HOUR 10 20 30 40 50 1510 1070 869 753 673 3040 2150 1760 1520 1360 5560 3930 3210 2780 2490 11 400 8070 6590 5710 5110 17100 12 100 9880 8550 7650 32 900 23 300 19 000 16 500 14 700 52 500 37 100 30 300 26 300 23 500 92 800 65 600 53 600 46 400 41500 189 000 134 000 109 000 94 700 84 700 60 70 80 90 100 615 569 532 502 462 1240 1150 1080 1010 934 2270 2100 1970 1850 1710 4660 4320 4040 3810 3510 6980 6470 6050 5700 5260 13 500 12 500 11 700 11 000 10 100 21 400 19 900 18 600 17 500 16 100 37 900 35 100 32 800 30 900 28 500 77 300 71 600 67 000 63 100 58 200 125 150 175 200 250 414 372 344 318 279 836 751 695 642 583 1530 1370 1270 1170 1040 3140 2820 2601 2410 2140 4700 4220 3910 3610 3210 9060 8130 7530 6960 6180 14 400 13 000 12 000 11 100 9850 25 500 22 900 21 200 19 600 17 400 52 100 46 700 43 300 40 000 35 500 300 1350 400 450 500 253 232. 216 203 192 528 486 452 424 401 945 869 809 759 717 1940 _ 1790 1660 1560 1470 2910 2670 2490 2330 2210 5600 5150 . 4790' 4500 4250 8920 8210 7640 7170 6770 15 800 14 500 13 500 12 700 12 000 32 200 29 600 27 500 25 800 24 400 550 600 650 700 750 182 174 166 160 154 381 363 348 334 322 681 650 622 598 576 1400 1330 1280 1230 1180 2090 2000 1910 1840 1770 4030 3850 3680 3540 3410 6430 6130 5870 5640 5440 11 400 10 800 10 400 9970 9610 23 200 22 100 21 200 20 300 19 600 800 850 900 950 1000 149 144 139 135 132 311 301 292 283 275 556 538 522 507 493 1140 1100 1070 1040 1010 1710 1650 1600 1560 1520 3290 3190 3090 3000 2920 5250 5080 4930 4780 4650 9280 8980 8710 8460 8220 18 900 18 300 17 800 17 200 16 800 1100 1200 1300 1400 1500 125 119 114 110 106 262 250 239 230 221 468 446 427 411 396 960 917 878 843 812 1440 1370 1320 1260 1220 2770 2640 2530 2430 2340 4420 4220 4040 3880 3740 7810 7450 7140 6860 6600 15 900 15 200 14 600 14 000 13 500 1600 1700 1800 1900 2009 102 99 96 93 91 214 207 200 195 iR9 382 370 358 348 339 784 759 736 715 695 1180 1140 1100 1070 1040 2260 2190 2120 2060 2010 3610 3490 3390 3290 3200 6380 6170 5980 5810 5650 13 000 12 600 12 200 11 900 11 500 `` .a warn rn fl ! For SI u ts: 1 j0i1�n1/��Ctbait E� $ mm, 1 cubic foot per hour = 0.0283 m3/h, 1 pound -force per square inch = 6.8947 kPa * Tablesu'plL4GE . APPROVED r DEC 032014 City of Tukwila 166 BUILDING DIVISION UNIFORM PLUMBING CODE / G 61,0/23Page of REZNOR® ANSI Z83.8b DESCRIPTION Reznor® V 3 Series Model UDAP gas -fired unit heat- ers are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial/industrial installations. Model UDAP heat- ers are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor® v3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily sus- pended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exte- rior of the cabinet for easy gas service connection. The preeminent new internal feature is the TcoRE2 ® heat exchanger and single burner combustion system. Other standard features include a single -stage gas valve, multi -try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, re- siliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic in- dicator lights to identify abnormalities in control func- tions. The new v3. Series unit heaters are designed to pro- vide all the features you expect in a Reznor heater plus improved efficiency, easier installation, and a new look - both inside and out. Form RZ-NA-C-UH Page 6 FILE COPY Ii6arlETAP Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 U.S. STANDARD FEATURES • Sizes 30-125 certified for residential heating application • Sizes 30-400 certified for commercial/industrial heating application • 82-83% Thermal efficient - TOP in its class! • 50-60°F Rise range • NEWTcoIE2® titanium stabilized aluminized steel heat exchanger • NEW patented** TcoRE2® single burner combustion system including a one- piece burner assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload pro • Transformer for 24-volt controls • Integrated circuit board with diagnostic indicator li • Multi -try direct spark ignition with 100% lockout • Fan relay (included on the circuit board) • Single -stage natural gas valve (field adjustable fo elevation) • Vibration/noise isolated fan and venter motors - designed for low noise operation • 2-pt and 4-pt Suspension - standard on all size • External terminal strip for 24-volt wiring ectioREVIEINED FOR 3h ODE COMPLIANCE APPROVED roperaticDE&,000 g 2014 City of Tukwila BUILDING DIVISION • External gas connection • Full fan guard - engineered for safety • Improved cabinet design with less visible hardware and a NEW Reznor appearance OPTIONAL FEATURES - FACTORY INSTALLED • Single -stage, propane gas valve (field adjustable for operation to 9,000 ft elevation) • Two -stage natural gas or propane gas valve - Sizes 60-400 • 409 or 316 Stainless steel heat exchangers • 208 or 230 Single phase voltage • Totally enclosed fan motor (Sizes 30-250, 115V only) • Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) ACCESSORIES - FIELD INSTALLED • Vent cap • Thermostat • Thermostat guard with locking cover • Vertical louvers - new design • Downturn nozzle kits - new design • Gas conversion kits (natural and propane) • Master/Slave controls for zoning up to six units • Ceiling suspension kit - Sizes 30-125 • Hanger kits for 1" pipe • Stepdown transformer (for 230/3 and 460/3 supply voltage) • Manual shutoff valves RECEIVED CITY OF TUKWILA NOV 0 6 2014 PERMIT CENTER PG114- °Mg, ** U.S. Patent No. 6,889,686 REVISION N�LL Page of Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS N-� i PandQ- Hanger Dimensions for 4-pt Suspension rQ 13' 1 TOP VIEW R - Hanger Dimension for 2-pt Suspension e- f3/8"-16 Female Thread - all suspension points 1 i B2p7S REZNOR F FRONT n. •�......... VIEW C i E2 1 R 1 Thermostat Connection (30-125 Vertical; 150-400 Horizontal) Line Voltage Inlet (connects at circuit board) Vent Connection (see Technical Data for size) Combustion Air Inlet REAR VIEW r K External H--0 Gas Connection RIGHT SIDE VIEW (Access Panel) REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 3 2014 City of Tukwila BUILDING DIVISION Form RZ-NA-C-UH Page 8 Page of Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS (cont'd) MODEL UDAP DIMENSIONS (± 1/16" Size A B C D E F G H J K M N P Q R 30,45 12-1/8 26-5/8 10 13-13/16 26 21-9/16 5-3/16 6-1/2 2-11/16 3-7/8 17-3/8 11/16 4-5/16 13 9-9/16 6 15-1/8 26-5/8 13 13-13/16 27 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 75 15-1/8 26-5/8 13 13-13/16 27-5/8 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 100 23-1/8 26-5/8 21 13-13/16 28-5/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 125 23-1/8 26-5/8 21 13-13/16 29-3/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 150, 175, 200 20-1/8 38-3/16 16 23 42 35-3/8 8-1/2 8-1/4 5-7/16 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 16-3/8 225, 250 26-1/8 38-3/16 22 23 42 35-3/8 13-1/16 8-13/16 9 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 15-5/8 300, 350, 400 34-1/8 41 30 23 42 35-3/8 17-1/16 9 11-13/16 7-5/16 27-11/16 1-3/8 8-3/16 22-3/16 16-3/16 MODEL UDAP DIMENSIONS (±2mm Size A B C D E F G H J K M N P Q R 30,45 308 676 254 351 660 548 132 165 68 98 441 17 110 330 243 60 384 676 330 351 686 548 200 165 140 98 441 17 110 330 267 75 384 676 330 351 702 548 200 165 140 98 441 17 110 330 267 100 587 676 533 351 727 548 368 165 222 98 441 17 110 330 267 125 587 676 533 351 746 548 368 165 222 98 441 17 110 330 267 150, 175, 200 511 970 406 584 1067 899 216 210 138 165 652 35 208 564 416 225' 250 664 970 559 584 1067 899 332 224 229 165 652 35 208 564 397 300, 350, 400 867 1041 762 584 1067 899 433 229 300 186 703 35 208 564 411 CLEARANCES Size Top Flue Connector Access Panel Non -Access Side Bottom* Rear inches mm inches mm inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 *Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 3 2014 City of Tukwila BUILDING DIVISION}) m RZ-NA-C-UH Page 9 Page of MODEL UDAP TECHNICAL DATA- Sizes 30 -125 Size 30 45 60 75 100 125 Input Heating Capacity BTUH 30,000 45,000 60,000 7 105,000 120,000 kw/h 8.8 13.2 17.6 22.0 30.8 35.2 Thermal Efficiency(%) 82 83 83 83 83 83 OutputHeatingCapacity" BTUH 24,600 37,350 49,800 62,250 87,150 99,600 kw/h 7.2 11.0 14.6 18.3 25.6 29.2 Gas Connection (inches) a Natural 1/2 1/2 1/2 1/2 1/2 1/2 Propane 1/2 1/2 1/2 1/2 1/2 1/2 Vent Connection Size c (inches diameter) 4 4 4 4 4 4 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 Maximum Over Current Protection (115V) B 15 15 15 15 15 15 Normal Power Consumption (watts) 109 155 155 217 276 354 Discharge Air Temperature Rise (°F) 50 55 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 M3/minute 12.9 17.8 21.8 27.5 36.7 45.9 Discharge Air Opening Area ft2 0.96 0.96 1.25 1.25 2.01 2.01 M2 0.09 0.09 0.12 0.12 0.19 0.19 Output Velocity FPM 475 656 616 770 668 763 M/minute 145 200 188 238 196 245 Fan Motor HP a Open 0.02 0.03 0.03 0.06 1/30 1/20 Endosed N.A N.A. N.A N.A 1/4 1/4 Fan Motor RPM 1550 1550 1550 1550 1050 1050 Fan Diameter(inches) 10 10 12 12 16 16 Sound Level dba @ 15 ft 40 40 40 49 54 55 Approximate Net Weight Ibs 54 59 67 72 96 101 kg 24 27 30 33 44 46 Approximate Ship Weight Ibs 61 66 74 79 118 123 kg 27 30 33 36 54 56 MODEL UDAP TECHNICAL DATASizes 150 - 400 A CSA rating for altitudes to 2000 ft. BSize shown is for gas connection to a single stage gas valve, not supply line size. °Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I-V-PV. If vent diameter is dif- ferent from vent con- nection, reducer/en- largers will be field -re- quired. °MODP = 2.25 x (larg- est motor FLA) + smallest motor FLA. Answer is rounded to the nearest commer- cially available circuit breaker. E All other in- formation in this table is based on a heater equipped with a stan- dard 115 volt open fan motor. Size 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency(%) 83 83 83 83 83 83 83 83 Output Heating Capacity" BTUH 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 kw/h 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection (inches)B Natural 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size c (inches diameter) 5 5 5 5 5 6 6 6 Control Mips (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection (115V) ° 15 15 15 15 15 20 20 20 Normal Power Consumption (watts) 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise (°F) 60 60 60 60 60 60 60 60 Air Volume CFM 1921 2242 2562 2882 3202 3843 4483 5123 M3/minute 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening Area ft2 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 M2 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 752 877 1003 820 911 802 936 1069 M/minute 229 267 306 250 278 244 285 326 Fan Motor HPE Open 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Endosed 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 .Fen+-tttetOr- - 1050 1050 1050 1050 1050 1050 1050 1050 tRialat FanFItEI r FOR _a 18 18 18 20 20 24 24 24 cOOMPLIANC @ 15 ft 51 52 53 56 56 59 61 62 AoproAAPPROMED Ibs 172 187 187 203 215 269 294 306 kg 78 85 85 92 98 122 133 139 ake Appro SCpTeP�o Ibs 4 kg 93 100 100 111 117 146 157 163 City of Tukwila BUILDING DIVISION Form RZ-NA-C-UH Page 7 Model RW 1548 The high capacity of the LVO RW1548 makes this pan washer a truly outstanding piece of • equipment for high pro- ducing bakeries, restau- rants or other food oper- ations. A powerful 5 h.p. and 10 h.p. dual pump system on the model delivers a high pressure wash that literally blasts sway residue on pots, pans, racks, bowls, gro- cery carts and utensils leaving them positively clean and completely sanitized. The LVO RW1548 is fully automatic, easy to install and economical to operate. It can be operated easily by any employee. 1'he RW1548 is made of 12 and 14 gauge stainless steel and is designed to last for years. It can sub- stantially reduce your labor costs and in many cases it will pay for itself in one year with the sav- ings. i Bun Pan Rack Cake Pan Rack INFRARED BURNERS • Quieter • Better than 8QYl. efficient • Cleaner burning • No burner tubing to clean or maintain in the wash tank • Repairs & maintenance of burners easier and more economical Bowl / Utensil Rack POWER VENTING Remove steam from your washer quickly and efficiently before it enters your work area. The 700 CFM American Fan is sure to work for you. Pot & Pan Washer • We Service What We Sell! tAs •.err It• RUE REQ'61 SPECIFICATIONS • Wash Cap: 48 pans Pump1;5HT. &1-10H.P 208, 230, 460V ,60 cycle 3 phase recirculates app.; 250 G.P.M. • ° • • Tinlers:.Was.h, delay, rinse - all adjustable .• . . Electrical Components: U.L. approved Wash Tank: 65 gal. cap_ - electric, steam, orgas' Construction: 12 and 14 G.A. Stainless` Steel " ` - Rinse Tank: SS, with two 9 KW electric booster heater to boost 120° water to 180°- 195°.sanitizing, rinse water. NOTE: Recommended Clearances Top - Front Sides" Rear • Bottom 36' 36" 16" •12 6"* *Gas machines must be installed 'with 6" adjustable legs when placed on a combustible floor. We Service What We Sell! t-V7 MAGI 9' STEW VDT NTH CRAP N[utATC* TRIUL EiGRARCE FU. vALVE f 4ATER COAECTIOR sLePORf nqE Electric Gas or Steam Injected Recirculating Steam 9• STEAM NEAT Tag FROet W W19! r9Cff 1-I!I CRAW RW1548 Gas Total Amperage 208V 133.1 95.6 45.6 94 u NOTE GXR n 3r JU 7T M R 0 0 13• 230V 122.3 88.4 43.2 Gas Rating 66,000 BTU Injected Steam Rating- 371bs @ 10 to 1.5 psi Recirculating Steam - 76 lbs 10 to 15 psi Rinse Tank Cap. - 20 gal. 60 sec. rinse @ 20 psi 14 gal/cycle IO wSE IEOU_ATOR ELECTRICAL ERTRAACE FILL VALVE r WATER COIECT1d1 RW1548 Electric 56 3/4 92-1/2' FITEtDERl 460V 62.1 45.2 22.6 O 0 Y O 0 0 11' NOTE. Dorn OP90C 31 NICE 77 NIGH LVO MANUFACTURING INC: P.O. Box_188; SOS- 2nd nue E lock1 apids lowa 51246 Phone: 712 / 472-3734 or 712'/ 472-3735 Toll Free 1-800-346-5749 Fax 712-472-2203 50 1/2• September '00 2 RINSE WATER BOOS1ER 8 I/2" 1 3'-O' SUGGESTED KEEP CLEAR PERIMETER BACK VIEW 8 1 7 59 1/4" 38 I/8" — ////////// PLAN VIEW LEFT SIDE VIEW 3' 1/1! _� DOOR 5N1610 2R 3/4' GAUGE PANEL CONTROL PANEL — WASH DOWN NOSE 25 1/2' FRONT EDGE OF PIT 70 FRONT EDOE OF HOUSINO 4 1 50 1/2" FRONT VIEW SALES APO ONLY PURPOSES'ONLY SPECIFICATIONS TOWER: PUMP: WASH TANK CAPACITY: STEAM UNE PRESSURE: STEAM CONSUMPTION: FRESH WATER RINSE: FRESH WATER RINSE CONSUMPTION: SHIPPING WEIGHT: INSTALLED WEIGHT: OPERATING WEIGHT: VOLTS-3 PHASE-60 HERTZ 208/240/480 VOLTS AVAILABLE 15 N.P. 240 G.P.M. 0 56 P.S.I.G. 60 GALLONS APPROXIMATE 10 P.S.I.G. MINIMUM 15 P.S.I.G. MAXIMUM 362 LBS. PER HOUR BASED ON 10 P.S.I. LINE PRESSURE RATE OF FLOW REQUIRED MINIMUM 9.1 G.P.M. 0 20 LINE PRESSURE 0 120' F. MINIMUM 9.1 GALLONS PER 60 SECOND RINSE CYCLE 2,950 LBS. APPROXIMATE 2,450 LBS. APPROXIMATE 3,010 LBS. APPROXIMATE ELECTRICAL REQUIREMENTS no m THE FOLLOWING FIGURES DO NOT INCLUDE A SAFETY FACTOR FOR DETERMINING DISCONNECT SIZE. BASE MACHINE WITH EXHAUST FAN VOLTS KW PHASE FULL. LOAD AMPS 208 TBD 3 45.1 240 TBD 3 41,0 480 TBD 3 20.5 A) B) C) n) E) F) G) CUSTOMER UTILITY CONNECTIONS 1-1/2' MANUAL DRAIN - FEMALE PIPE CONNECTION 1-1/2' AUTOMATIC DRAIN - FEMALE PIPE CONNECTION 1" WATER FILL - FEMALE. PIPE CONNECTION 8" EXHAUST FAN - FLANGE CONNECTION ELECTRICAL CONNECTION 1-1/2" STEAM INLET - FEMALE PIPE CONNECTION 3/4" STEAM CONDENSATE - FEMALE PIPE CONNECTION NOSE: MANUFACTURER PESERVES THE RIGHT OF MODIFICATIONS WITHOUT PRIOR NOTICE. KRS. to mhos. Oa e1 NH MaHa Newh, a m..lmwn of 18-18 m N4N 1. r.pea-.d. w Nmmy ne.,en,.n Iie1 .mn • 1 Wn aM m bent . Mn M4.ln,. Ysa„ 49 soon Han. TM ndud(nq veM la N M pmRd.d aM hnN4d STEAM COLL HEATED TANK TTITT3 STEAM RINSE WATER BOOSTER ON ROOF Z NOTE: MANUFACTURER RESERVES THE RIGHT OF MODIFICATIONS WITHOUT PRIOR NOTICE - SERIAL. ORI< ORDER: OON590001AL PROPRIETARY NOTK.E 14E� ramie GROUP 3 4- ALVEY WASHING EQUIPMENT AR ARMOR CROUP COMPANY HAWN, OHO 'MU 1YJms051C0_a0P4SL1.cr_M.4Qal KS-48 TOq 51000 Coil I O)9.t,sQON Wlh BQg410r - "� DATE 2/9/2QQ.R_ n,o Pr .43F V- SCALE N9nn GAO MO. KS48—SCHB 2 PLAT STAMP: 6/15/2010 7:57 NA w xac CM. BY 1 LVO Manufacturing, Inc. 808 N. 2nd Avenue E., P.O. Box 188 Hock Rapids, L151246 w w.lvo nfg.coin (712) 472-3734 1-800-346-5749 Fax (712) 472-2203 RW1548 Specifications Overall Dimensions Width — 591/2" Height — 92 1/2" (94 1/2" gas units) Wash Area — 31 ' 2" x 42" x 76 '/2" Depth — 67 1/2" Height above floor— 81 '' 2" (Pit Models) Hot Water System 1" hot water supply required, union provided 140°F water required at the machine 168 GPH at 20 PSI (14 gal/cycle x 12 cycle/hr) Rinse booster: (2) 9 kW heating element in a 20 gallon rinse tank OR %" steam coil in a 20 gallon rinse tank (Steam Only) Full Load Amps 208 Volt 230 Volt 460 Volt Electric 132.3 121.7 61.8 Gas 94.8 87.8 44.9 Steam 44.8 42.6 22.3 Gas System (Gas Machines Only) %'' gas supply Natural: 7" W.C. minimum inlet, 6" W.C. main manifold — 75,000 BTU Propane: 11" W.C. minimum inlet, 10" W.C. main manifold — 60,000 BTU 4" stainless steel chimney on back of machine Steam System (Steam Models Only) %" steam line, 10-15 PSI 76 lbs/hr average — Injected 76 lbs/hr average — Recirculating Wash System l0 Hp & 5 Hp pumps in series recirculate approximately 240 GPM @ 55 PS[ Heat: Electric — (1) 9 kW & (1) 4 '/2 kW heating elements Gas — (3) 25,000 BTU rated infrared burners — 75,000 BTU total Propane — (3) 20,000 BTU rated infrared burners — 60,000 BTU total Injected & Recirculating Steam - 10 to 15 PSI, 37 lbs/hr average 65 gallon wash tank 1 1/2" copper drain 8" steam exhaust vent companion flange (Requires PVC, CPVC, or stainless steel field installed duct) 4 City of Tukwila Department of Community Development November 14, 2014 RICK PHILLIPS 234 FIFTH AVE S EDMONDS, WA 98020 RE: Correction Letter # 1 to Revision #1 PLUMBING/GAS PIPING Permit Application Number PG14-0156 TOP POT DOUGHNUTS - 401 BAKER BLVD Dear RICK PHILLIPS, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. 1. Provide calculations for gas pipe to show gas pipe sized to meet demand of all combined gas appliances. Include lengths of gas pipe and size supplying each separate appliance. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, fer Marsh it Technician o. PG14-0156 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0156 DATE: 11/20/2014 PROJECT NAME: TOP POT DOUGHNUTS SITE ADDRESS: 401 BAKER BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 X Revision # 1 after Permit Issued DEPARTMENTS: Awc)- Bhilding Division Public Works Fire Prevention Structural n n Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) kdr ,PkrAvI.S DUE DATE: 12/30/14 ciatril- I REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0156 DATE: 11/06/14 PROJECT NAME: TOP POT DOUGHNUTS BITE ADDRESS: 401 BAKER BLVD Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Building Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/04/14 Approved n Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:_, 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0156 DATE: 10/16/14 PROJECT NAME: TOP POT DOUGHNUTS SITE ADDRESS: 401 BAKER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AW Building Division Public Works/ Fire Prevention Structural n n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/21/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 11/18/14 Approved Corrections Required Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: Yet rvo\rc Sne4 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: lbtSITE ADDRESS: Icvp, PERMIT NO: 7P6 Z-h D 1S1 ORIGINAL ISSUE DATE: 'Q—� ) t f REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: G. 4-0 (:? . , w- Received by: i Z, REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I I- Plan Check/Permit Number: P 6 j si- o l 5� ❑ Response to Incomplete Letter # 121 Response to Correction Letter # Revision # .I after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Top Par Dovy-l►fou-4-s Project Address: 0) Q A I L V D fit, k W i 1 x1 , coA Contact Person: P. 0'c b( 'P ii / /,'fi Summary of Revision: yY1 oft 6eA-0iI e cda(GVL44io/c1S e,, Lc(4-1 !45 5)Ze LL) et 5 e 4 e r ✓vi,%ved MEWED CITY aFfuttwu NOV 2 0 2014 Phone Number: 2,0 �v S W 9-- 74/53 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ,4k) 12( Entered in TRAKiT on //(D-0//y City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 _ 5 19 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # (2] Revision # j. after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: p(j 1 0 156 Project Name: To p Po r O o uc9 k tou+S Project Address: 4 0( BAKER 13 L V D 1 U I< t.41 i la t-V A, Contact Person: R G K 9- '1 I;,1S Phone Number: ao 0 G Li /- 74f53 Summary of Revision: A c)c +o per v14 4- PG Ili- 015G a P,?iN9 to a- ge ZAJOr vti-- ecoers a-•- exi5+%N9 gas +t-c4- hu5 a 1Jalve -cor u4ofe 'Q5. OW OF TUKWIIA NOV 1,06 20110 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio, Received at the City of Tukwila Permit Center by: -entered in TRAKiT on WCI PLUMBING LLC Page 1 of 2 Washington State Department Qf Labor & Industries WCI PLUMBING LLC Owner or tradesperson LESSARD, MATTHEW JAMES Principals LESSARD, MATTHEW JAMES, PARTNER/MEMBER HOLOBAUGH, TRENT LEE, PARTNER/MEMBER CARTER, PAUL FLYNN, PARTNER/MEMBER LESSARD, MATTHEW JAMES, AGENT Doing business as WCI PLUMBING LLC WA UBI No. 603 166 416 234 5TH AVE SOUTH EDMONDS, WA 98020 425-774-4185 SNOHOMISH County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. WCIPLPL891 R3 Effective — expiration 12/23/2011-12/23/2015 Bond Travelers Cas and Surety Co of America Bond account no. 105693076 Received by L&I 12/23/2011 Insurance Phoenix Insurance Company, The Policy no. DTC0526D7304PHX14 $6,000.00 Effective date 12/20/2011 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603166416&LIC=WCIPLPL891 R3&SAW= 10/27/2014