HomeMy WebLinkAboutPermit PG14-0162 - LUCKY LIQUOR - GREASE TRAP AND WASTE / WATER PIPINGLUCKY LIQUOR
10325 E MARGINAL WAY S
PG14-0162
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 0423049117 Permit Number: PG14-0162
Address: 10325 E MARGINAL WAY S Issue Date: 11/17/2014
Permit Expires On: 5/16/2015
Project Name: LUCKY LIQUOR
Owner:
Name: CHASE BARBARA
Address: 1134 LAKESIDE AVE S , SEATTLE, WA,
98144
Contact Person:
Name: AARON ERISMAN Phone: (206) 307-4887
Address: 10325 E MARGINAL WAY S , TUKWILA,
WA, 98168
Contractor:
Name: BRITTON PLMB & MECHANICAL INC Phone: (425) 395-6007
Address: 8040 161ST AVE NE, #413 ,
REDMOND, WA, 98052
License No: BRITTPM8711B Expiration Date:
Lender:
Name:
Address: , , ,
DESCRIPTION OF WORK:
REPLACE WASTE PIPE FOR BAR AND KITCHEN. INSTALL NEW GREASE TRAP. REPIPE WATER TO BAR AND KITCHEN
Valuation of Work: $6,000.00
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Fees Collected: $296.08
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2014
2012
Permit Center Authorized Signature:
Date: Oil Iii
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: I 1 — 11
qt/
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
8004 GROUNDWORK
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
CITY OF TUKT- ;A
Community Develop>. —at Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/l>,.»s Permit No.?b [1-i O L
Project No.
Date Application Accepted: to -A-4/4
Date Application Expires: 4 ---)—b
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.:
j -NW ,i1 J*% 1 A Suite Number:
Tenant Name: l,_V
Site Address: I C -S I S
PROPERTY OWNER
Name: —5 3t...0
, 1
Address:
City:
State:
Zip:
CONTACT PERSON — person receiving all project
communication
Name: - 3V\ `
M tl�,�,,� 1
, I , v
Address:
r 0 1_5 e M Pe-,, K1 vo.s\j ‘)
,
City: 1 t) i State: ; jA
Zip: 96 I g C
0
Phone: 206X �)� . 4s
Email:
Floor:
New Tenant: Q Yes ❑.. No
PLUMBING CONTRACTOR INFORMATION
Company Name: ; e \ \3:�. t et. cc
Address: cl.� 0 (6( 51- t�vekir (���
�2-( Uhl
City: State: Zip:ct rt.-OS`Z
Phone:425--sCtSFax:
Contr Reg No.: Zit t 0Alt14QExp Date:
Tukwila Business License No.: 000 '.1\/
Valuation. of Project (contractor's bid price): $ ®c c
Scope of Work (please provide detailed information): UGC Q L X - (` DC- Q
e. C/� C�r c•v� tc •kcc °.
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures an gas piping outlets being installed and the qua below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
1,
Shower, single head trap
Sinks
T
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
' '
gallon capacity)
i
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric-
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
i
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE TATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AXJ'I'H S' IZED
Signature:
Print Name:
�t T-I..Gti
Mailing Address: 16 WAN S.
Date: 10 — 1
Day Telephone: Z66 - 5 O 7 - ligs
�1 114L */t;R
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx
Revised. August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
Cash Register Receipt
City of Tukwila
ACCOUNT ( QUANTITY
PAID
39.14.
PG 14-01
Address: 10325,.E MARGINAL WAY S Apn: 0423049117
$239.14
PLUMBING
$227.75
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$195.25
TECHNOLOGY FEE
$11.39
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3578
R000.322.900.04.00
0.00
$11.39
$239.14
Date Paid: Monday, November 17, 2014
Paid By: LUCKY LIQUOR
Pay Method: CREDIT CARD 020216
Printed: Monday, November 17, 2014 1:02 PM 1 of 1
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT
QUANTITY PAID
41054,
ermitTRA
14 0162
ress;10325"E MARGINAL WAY Sr
n:°0423049117
56.94
PLUMBING
$56.94
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R3412
R000.322.103.00.00
0.00
$56.94
$56.94
Date Paid: Tuesday, October 28, 2014
Paid By: KALI ERISMAN
Pay Method: CREDIT CARD 041815
Printed: Tuesday, October 28, 2014 12:18 PM 1 of 1
CrIWSYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION Na PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukvvila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 438-9350
Project: , e
L_LJCI<Li L ea ,J 0 &,
Type of Inspection:
Pt J .mK),
, .
f-, 4 Pt 1
Address: , 1
I 0 7-.'„) e . AW 6: NA L
Date Called:
Special Instructions:
.------
Date Wanted:
P.m.
'Requester:
Phone No:
3°7 —'4&-r7
ZApproved per applicable codes.
0 Corrections required prior to approval.
COM MENTS:
Inspettor:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. ' PERMIT NO,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: 1 _ ,
Type of Inspection:
Address:
5 st: 1J A-L-
( 0 -3 7--f , M A
Date C ed:
ci
Special Instructions:
Date Wanted:
2(.
1 ,,i,
VI
a.m.
Requester:
Phone No:
Approved per applicable codes.
COMMENTS:
Inspctor:
C-e%'4sz>
Corrections required prior to approval.
Date: ,Lio 14
r
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
SPECIFICATIONS (PATG-2025)
1. 3" inlet and outlet connections (No -Hub)
2. Max flow rate: 25 GPM
3. Liquid capacity: 28 Gallons
4. Max grease capacity: 98 Pounds
5. Unit weight w/std. covers: 63 Pounds
6. Kitchen -duty polyethylene cover with flush
1/4" stainless steel bolts. (Load Capacity 500 lbs.)
7. Maximum operating temperature 190°F.
NOTES
1. Listed by IAPMO to ASME grease interceptor
standard #A112.14.3
2. Factory installed Built -In Flow control.
3. For gravity drainage applications only. Do not use
for pressure applications.
4. 3/8" thick seamless high density polyethylene walls.
5. Riser is also available for burial.
6. Cover placement allows full access to tank for proper
maintenance.
7. Vent not required unless per local code.
8. Engineered inlet and outlet diffusers are removable
to inspectdean piping.
9. For on -the -floor or buried applications.
10. Integral AfoRelief/'Anti-siphon
11. Three outlet options for easy rough in. Unit
shipped with outlet diffuser in outlet "B".
DIFFUSION FLOW TECHNOLOGY
I he inlet diffuser splits Incoming effluent into two paths
that utilize the entire liquid volume of the tank for efficient
grease separation. The calibrated openings greatly reduce
effluent turbulence. The effluent enters the main chamber
without disturbing the existing grease or sediment layers.
The integral air relief/anti-siphon in the top of the outlet diffuser
allows pressure stabilization within the unit during operation.
The bottom of the outlet diffuser allows only effluent which is
free of grease to exit the tank. It can easily be attached to any
of the three outlets provided to ease jobsite piping layouts.
ENGINEER SPECIFICATION GUIDE
ScTiier I rapper I!'" grease interceptor model # shall
be lifetime guaranteed and made in USA of seamless,
rotationally -molded High Density Polyethylene with minimum
uniform wall thickness. Interceptor shall be furnished for abo
below grade installation. Interceptor shall be built in accorda
ASME A112.14.3 (type C), with built-in flow control, built-in t
caps and three outlet options. Interceptor flow rate shall be
GPM. Interceptor grease capacity shall be Ibs
Cover shall provide water/gas-tight seal and have minimum
500 Ibs load capacity.
OPTIONS:
• Risers for extending covers to grade from 4" to 36"
• Male pipe thread connections
• 3" plain and male pipe thread connections
• 1/4" Steel treadplate cover
• Recessed for tiles steel cover
grease
Inueceplae
all
solid.
•eparalor• Intercepters
chemical
waste tanks
Process
warms
FILE COPY
Ilk St
TOP VIEW
(W/O COVER)
of inlet-
29-3/4"
Outlet "C"
See note #10
Outlet "B"
(standard)
A
1
10-1/4"
23- /4"
or REVIEWED FOR
teODE OOMPLIA C
APPROVED
1OV 1 0 2014
0
City of Tukwila
BUILDING DIVISION
Static Waterline—
t
7-1/4"
\ r
Engineered inlet and
outlet diffusers
(See Description)
SECTION A -A
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SCHIER PRODUCTS. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SCHIER PRODUCTS IS
PROHIBITED.
PART NUMBER: PATG-2025
— q. of
outlet
16"
DESCRIPTION:
TRAPPER SERIES POLYETHYLENE GREASE
INTERCEPTOR, 25 GPM, 98 POUNDS GREASE
STORAGE 28 GALLONS LIQUID HOLDING CAPACITY
RECEIVE?
OCT. 2 9 2014
TUK`rvtL
PUBLIC WORT^
ECEIVED
CITY OF TUKWILA
OCT 2 8 2014
PERMIT CI_NT'E
R
A
END VIEW
SPECIFICATION SHEET
Schier Products
9500 Woodend Road
Edwardsville, KS 66111
Tel: 800-827-7119
Fax: 800-827-9664
www.schierproducts.com
Made in the U.S.A
SCHIER
PRODUCTS
Pioneering Drain Line Purity
DWG BY: TEU
DATE: 11/21/06
REV: 5-12/16/11
MATL: PE
—cute_ \:. W
L uc� LAe.�yo�
f�
\325 E. \i\k�.vc_��.xy
kfr
WS c)1/4t`C,tk v c\S4-
, '"& \'L LQC Code t 4 < •
ar c%- 6c, A-ZS
0QJ
FILE COPY
Permit No.
cO
E V-ks\v
� S
PG JLJ O1&2
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 10 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 2 8 2014
PERMIT CENTER
RECEIVE
OCT, 292014
TLIKWiuk
PUBUC WORKS
LL C L\ ct_ur r
tp'
W�T�tL
T1 oiv,Q Sw� Iit. C .?
1—
(
vce-\we'Lec
UZKv)
* l2 S
'It Cl,�
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 1 0 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 2 8 2014
PERMIT CENTER
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0162 DATE: 10/28/14
PROJECT NAME: LUCKY LIQUOR
SITE ADDRESS: 10325 E MARGINAL WAY S
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
mt
Building Division or
A{/4.iT)I'
public Works
Fire Prevention
Structural
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
Planning Division ❑
Permit Coordinator
DATE: 10/30/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 11/27/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
BRITTON PLMB & MECHANICF T LLC
Page 1 of 2
0 Washington State Department of
Labor & Industries
BRITTON PLMB & MECHANICAL LLC
Owner or tradesperson
BRITTON, PHILLIP P
Principals
BRITTON, PHILLIP P, PARTNER/MEMBER
Doing business as
WA UBI No.
603 282 691
8040 161ST AVE NE #413
REDMOND, WA98052
425-395-6007
KING County
Business type
Limited Liability Company
Governing persons
PHILLIP
PAUL
BRITTON
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
PLUMBING
License no.
BRITTPM871JB
Effective — expiration
04/02/2013— 04/02/2015
Bond
Great American Ins Co $6,000.00
Bond account no.
1468921
Received by L&I Effective date
04/02/2013 03/15/2013
Expiration date
Until Canceled
Insurance
Ohio Cas Ins Co $1,000,000.00
Policy no.
55723172
Received by L&I Effective date
02/17/2014 02/17/2014
Expiration date
02/17/2015
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603282691&LIC=BRITTPM871JB&SAW= 11/17/2014