HomeMy WebLinkAboutPermit PG14-0176 - DOT SOUTH BASE - COMPONENT SPY - GAS METERDOT SOUTH BASE
COMPONENT SPY
12100 E MARGINAL WAY S
PG14-0176
Parcel No:
Address:
Project Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
7340600421 Permit Number:
12100 E MARGINAL WAY S
DOT SOUTH BASE - COMPONENT SPY
Issue Date:
Permit Expires On:
PG 14-0176
12/9/2014
6/7/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
KING COUNTY -TRANSIT
500 4TH AVE ADM-ES-0800, SEATTLE,
WA, 98004
JUSTIN DICKENS
7717 DETROIT AVE SW , SEATTLE, WA,
98106
MACDONALD MILLER FACIL SOLUTIO
PO BOX 47983 , SEATTLE, WA, 98146-
7983
License No: MACDOFS980RU
Lender:
Name:
Address:
Phone: (206) 768-4034
Phone: (206) 768-4180
Expiration Date:
DESCRIPTION OF WORK:
INSTALL (1) NEW GAS METER PER PLANS
Valuation of Work: $4,200.00
Water District: 125
Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW
SEWER SERVICE
Fees Collected: $126.76
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2012
Permit Center Authorized Signature:
ANc, Att
Date: t21064tii
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:/7�
Print Name:
Date: / 2 - `i — I `"
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
9002 ROUGH -IN GAS PIPING
9001 UNDERGROUND
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
)(7Plumbing/Gas Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For o fice use onl
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address:
King Co Assessor's Tax No.: 734060-0421
12100 East Marginal Wy S
Tenant Name:
Suite Number: Floor: 1
DOT - South Base Maintenance (Operation Bldg) New Tenant: ❑ Yes m..No
PROPERTY OWNER
Name: King County Metro
Address: 12100 E Marginal Wy S
City: Tukwila State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Justin Dickens
Address: 7717 Detroit Ave SW
City: Seattle State: WA Zip: 98106
Phone: (206) 768-4034 Fax: (206) 768-4035
Email: justin.dickens@macmiller.com
PLUMBINGCONTRACTOR INFORMATION,
Company Name: Macdonald Miller
Address: 7717 Detroit Ave SW
City: Seattle State: WA Zip: 98106
Phone: (206) 768-4278 Fax: (206) 768-4279
Contr Reg No.: MACDONFS98011 Exp Date: 01/06/2015
Tukwila Business License No.: BUS-0100868
Valuation of Project (contractor's bid price): $ 4,200
Scope of Work (please provide detailed information):
install (1) new gas meter per plans
Building Use (per Int'I Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
H:\Applications\Porms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-I I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 min) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
1
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of flan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: Date:
Print Name: Darla Doll
Day Telephone: (206) 768-4278
Mailing Address: 7717 Detroit Ave SW Seattle WA 98106
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9.1 l.docx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
Cash Register Receipt
City of Tukwila
ACCOUNT QUANTITY
PAID
517.92
PG14-0176 Address:12100 E MARGINAL;W
n: 7340600421;
126.76 -
GAS
$121.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.38
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$4.88
PG14-0177 Address: 12100 E MARGINAL WAY
0:4340600421.
391.1
GAS
$121.88<
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.38
PLUMBING
$264.40
EA SUPPLEMENTAL PERMIT
R000.322.100.00.00
0.00
$264.40
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3642
R000.322.900.04.00
0.00
$4.88
$517.92
Date Paid: Thursday, November 20, 2014
Paid By: MACDONALD MILLER
Pay Method: CHECK 4081
Printed: Tuesday, November 25, 2014 11:01AM 1 of 1
SYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NCI PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Poject:
SC•tt k ‘1) 4-St°
Type at -Inspection.
‘-- I r.-i AC_
Address:
,
Q_Gt 04,,
Date Called:
Special Instructions:
cial-k
IkAirig
Date Wanted:
t Z— [ ( 0 i / Li
----rn
(3' .'
PlIT).
Requester:
Phone No:
EApproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
CI) RNG k --..t
NJ
— Ax 1144
-__..
C‘Q/VIA.; i El P i r_.-; khd
insOctor:
—"--1-1/1 A A —kJ, —
I EINSPECTION FEE REQUIRED. Prior tt next inspection. fee must be
el at 6300 Southcenter 13(vd., Suite 100, Call to schedule reinspection.
Date: i
/iD
c)(
MacDonald -Miller
Job Name:
Service
Location: •
Job Test! Inspection Report
n17DiaolfMat SW
SOON WA NID$.1 03
Plow: 2144134400
Fa-761413
witeittompurceces
lac fne>11,19 Job #: 73/ y- ?Oro
Type of Pressure: Hydrostatic: Air:
Length of Test:
Owners Rep or
General Contractor:
Inspector.
Comments:
//14
Foreman:
Date:
Date:
/.4°F Date: / Z
41 r
?ERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG14-0176 DATE: 11/21/2014
PROJECT NAME: DOT SOUTH BASE - COMPONENT SUPPLY
SITE ADDRESS: 12100 EAST MARGINAL WY S
X Original Plan Submittal
Response to Correction Letter # Revision # after Permit Issued
Revision # before Permit Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator n
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 11/25/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 12/30/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
MACDONALD/MILLER FAC SOT ` "NC
Page 1 of 3
Washington State Department of
Labor & Industries
MACDONALD/MILLER FAC SOL INC
Owner or tradesperson
SIMONDS, DERRICK R
Principals
SIMONDS, DERRICK R, PRESIDENT
WEBSTER, MARK E, VICE PRESIDENT
NOEL, STEPHANIE W, MEMBER
SIGMUND, FREDRIC, PRESIDENT
(End: 01/04/2011)
LOVELY, STEVE C, VICE PRESIDENT
(End: 01/04/2011)
HACK, RICHARD, SECRETARY
(End: 01/04/2011)
KOPET, TYLER, TREASURER
(End: 01/04/2011)
TURLEY, DOUGLAS, CHIEF EXECUTIVE
OFFICER
(End: 01/04/2011)
TURLEY, DOUGLAS, CHIEF OPERATING
OFFICER
(End: 01/04/2011)
GOUGH, DAVID ANTHONY, DIRECTOR
(End: 08/29/2014)
Doing business as
MACDONALD/MILLER FAC SOL INC
WA UBI No.
602 254 260
PO BOX 47983
SEATTLE, WA98106
206-768-4180
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
MACDOFS980RU
Effective — expiration
12/31/2002— 01/03/2015
Active.
Meets current requirements.
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 12/09/2014