Loading...
HomeMy WebLinkAboutPermit PL11-021 - VERIZON WIRELESS - SEPA AND WIRELESS COMMUNICATION FACILITYVERIZON WIRELESS S 109' ST & BEACON AVE S PL11-022 L11-028 E11-009 SEPA & WIRELESS COMMUNICATION TELECOMMUNICATIONS FACILITY City of - Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov DETERMINATION OF NON -SIGNIFICANCE (DNS) File Number: E 11-009 Applied: 07/05/2011 Issue Date: 09/20/2011 Status: APPROVED Applicant: VERIZON WIRELESS SEAQ PONCHO Lead Agency: City of Tukwila Description of Proposal: SEPA REVIEW OF VERIZON WIRELESS APPLICATION TO REPLACE 6 PANEL ANTENNAS ON AN EXISTING SEATTLE CITY LIGHT ELECTRICAL TRANSMISSION TOWER WITH 12 NEW PANEL ANTENNAS ALONG WITH THE ADDITION OF 6 GROUND -MOUNTED EQUIPMENT CABINETS. THE PROJECT SITE IS AN EXISTING TOWER WCF FACILITY LOCATED IN AN LDR ZONE. Location of Proposal: Address: Parcel Number: Section/Township/Range: 6874201170 SE-3 -23-4. S. 109 St. & Beacon Ave S. The City has determined that the proposal does not have a probable significant adverse impact on the environment. An environmental impact statement (EIS) is not required under RCW 43.21c.030(2) (c). This decision was made after review of a completed environmental checklist and other information on file with the lead agency. This information is available to the public on request. This DNS is issued under the option DNS process in WAC 197-11-355. There is no further comment period. ack Pace, Responsible Official City of Tukwila 6300 Southcenter Blvd Tukwila, WA 98188 (206)431-3670 Date ni /Z,7/1/ Any appeal shall be linked to a specific governmental action. The State Environmental Policy Act is not intended to create a cause of action unrelated to a specific governmental action. Appeals of environmental determinations shall be commenced within the time period to appeal the governmental action that is subject to environmental review. (RCW 43.21C.075) . ..... nniono C.1 nnn n_:...-J. nn 4n ell,. 4 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTICE OF DECISION To: Bill North, The North Group Seattle City Light, Owner State Department of Ecology, SEPA Division King County Assessor PROJECT: Verizon Wireless Facility Upgrade — SEAQ PONCHO FILE NUMBERS: E11-009 (SEPA/Environmental Review) ASSOCIATED FILES: L11-028 (Wireless Facility Permit), PL11-021 (Project File) APPLICANT: Bill North of The North Group on behalf of Verizon Wireless REQUEST: SEPA approval to upgrade of a wireless facility within the Low Density Residential zoning district. The project includes replacement of 6 panel antennas with 12 new panel antennas on an existing electrical transmission tower, and the addition of six new ground -mounted equipment cabinets which are proposed to be located within an enclosure at the base of the tower. LOCATION: North of the intersection of S. 109th St. and Beacon Ave S. (parcel number 687420-1170). This notice is to confirm the decision reached by Tukwila's SEPA Official to issue a Determination of Non -significance (DNS) for the above project based on the environmental checklist and the underlying permit application. Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at: Tukwila Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Monday through Friday 8:30 a.m. - 5:00 p.m. The project planner is Jaimie Reavis, who may be contacted at (206) 431-3670 for further information. The decision is appealable to the Superior Court pursuant to the Judicial Review of Land Use Decisions, Revised Code of Washington (RCW 36.70C). 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director FINAL STAFF EVALUATION FOR ENVIRONMENTAL CHECKLIST File No: E11-009 SUMMARY OF PROPOSED ACTION The proposal is to upgrade an existing wireless telecommunication facility located on an electrical transmission tower and within the associated equipment enclosure located at the base of the tower. Equipment proposed with the project includes replacement of 6 panel antennas on the tower with 12 new panel antennas, and the addition of six new ground -mounted equipment cabinets which are proposed to be located within an enclosure at the base of the tower. II. GENERAL INFORMATION Project Name: Verizon Wireless — SEAQ PONCHO Applicant: Bill North, The North Group Property Owner: Seattle City Light Location: North of the intersection of S. 109th St. and Beacon Ave S. (parcel number 687420-1170). Zoning and Comprehensive Plan Designation: Low Density Residential (LDR) The following information was considered as part of review of this application. 1. SEPA Checklist and ESA screening checklist dated July 1, 2011. 2. Plans prepared by KDC Architects.Engineers, P.C., dated April 20, 2011. NOTE: Technical reports and attachments referenced above may not be attached to all copies of this decision. Copies of exhibits, reports, attachments, or other documents may be reviewed and/or obtained by contacting Jaimie Reavis, Assistant Planner, 6300 Southcenter Boulevard, Tukwila, Washington, 98188, Phone: (206) 431-3659. III. REVIEW PROCESS The proposed action is subject to State Environmental Policy Act (SEPA) review as the project does not meet the exemptions listed under WAC 197-11-800. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206- 431-3665 IV. BACKGROUND/PROPOSAL The proposal is to upgrade an existing wireless facility located on an existing electrical transmission tower in Seattle City Light right-of-way north of the intersection of S. 109th St. and Beacon Ave S. (parcel number 687420-1170). Twelve new panel antennas will replace six existing panel antennas, and six new ground -mounted equipment cabinets are proposed to be added within an existing chain link fence equipment enclosure. The chain link fence includes privacy slats to screen the existing and new equipment from view. V. REVIEW OF THE ENVIRONMENTAL CHECKLIST The following lists the elements contained within the Environmental Checklist submitted for the proposed project. The numbers in the staff evaluation correspond to the numbers in the Environmental Checklist. If staff concurs with the applicant's response, this is so stated. If the response to a particular item in the checklist is found to be inadequate or clarification is needed, there is additional staff comment and evaluation. A. BACKGROUND: 1-4- Concur with checklist. 5- Project construction shall occur once all applicable permits are obtained. 6-7- Concur with checklist. 8-9- A business license must be obtained for the wireless facility at this location, per TMC 18.58.070, in addition to the Type 1 land use and building permit approval. A Public Works Permit will be required to underground power and telecommunications from the existing utility pole number 1339373 (Verizon Wireless P.O.C.) depicted on sheet E-2. Electrical permit(s) may also be required. 10-12 - Concur with checklist. B. ENVIRONMENTAL ELEMENTS: 1. Earth: a-h Concur with checklist. 2. Air: a-c Concur with checklist. 3. Water: Surface: a(1-6) — Concur with checklist. Ground: b(1-2) - Concur with checklist. Water Runoff (including storm water): c(1-2) — Concur with checklist. d - Concur with checklist. 4. Plants: a -d- Concur with checklist. JR Page 2 of 4 July 21, 2011 H:\Wireless Telecommunication Facilities\PL11-021_Verizon_Type 1_SEAQ PONCHO\SEPA 5. Animals: a- Animals known to be in the vicinity of the project site include a variety of birds, including hawks, eagles, and songbirds. b- Concur with checklist. c- This area is part of the Pacific Flyway, a primary corridor for migratory bird species. d — Concur with checklist. 6. Energy and Natural Resources: a-c - Concur with checklist. 7. Environmental Health: a(1-2) - Concur with checklist. b (1-3) - Concur with checklist. The project must meet City of Tukwila noise ordinance requirements. Compliance with applicable local, state and federal noise regulations will mitigate any potential adverse noise impacts associated with the project. 8. Land and Shoreline Use: a-d- Concur with checklist. e — The current zoning classification of the site is Low Density Residential (LDR). f- The current Comprehensive Plan designation of the project site is Low Density Residential (LDR). g- Concur with checklist. h- The area of the parcel on which the electrical transmission tower and the equipment enclosure are located is flat and no portion of the area in which work will occur is classified as environmentally sensitive. However, the project site is part of a large parcel/electrical transmission right-of-way that includes areas classified as Class 2 Landslide Hazard Areas, as well as areas covered by wetlands and watercourses and associated buffers. 1-1- Concur with checklist. 9. Housing: a-c - Concur with checklist. 10. Aesthetics: a-c - Concur with checklist. 11. Light and Glare: a-d - Concur with checklist. 12. Recreation: a-c - Concur with checklist. 13. Historic and Cultural Preservation: a-c - Concur with checklist. 14. Transportation: a- Concur with checklist. JR Page 3 of 4 July 21, 2011 H:\Wireless Telecommunication Facilities\PL11-021_Verizon_Type 1_SEAQ PONCHO\SEPA b- The site is served by public transit. Bus stops for Metro bus route 107 (Rainier Beach to Renton) are located along 51st Ave S to the east of the project site. c-g - Concur with checklist. 15. Public Services: a-b- Concur with checklist. 16. Utilities: a-b - Concur with checklist. VI. COMMENTS: No comments were received during the Notice of Application period for this project. VII. CONCLUSION The proposal can be found to not have a probable significant adverse impact on the environment and pursuant to WAC 197-11-340 a Determination of Nonsignificance (DNS) is issued for this project. This DNS is based on impacts identified within the environmental checklist, attachments, and the above Final Staff Evaluation for Environmental Checklist File No. E11-009, and is supported by plans, policies, and regulations formally adopted by the City of Tukwila for the exercise of substantive authority under SEPA to approve, condition, or deny proposed actions. Prepared by: Jaimie Reavis, Assistant Planner Date: August 31, 2011 JR Page 4 of 4 July 21, 2011 H:\Wireless Telecommunication Facilities\PL11-021_Verizon_Type 1_SEAQ PONCHO\SEPA eat/ at ffulituita Department Of Community Development AFFIDAVIT OF DISTRIBUTION I, Jaimie Reavis HEREBY DECLARE THAT: Notice of Public Hearing X Determination of Non -Significance Notice of Public Meeting Mitigated Determination of Non - Significance Board of Adjustment Agenda Packet Determination of Significance & Scoping Notice Board of Appeals Agenda Packet Notice of Action - Planning Commission Agenda Packet Official Notice Short Subdivision Agenda Notice of Application Notice of Application for Shoreline Mgmt Permit Shoreline Mgmt Permit _ _ FAX To Seattle Times Classifieds Mail: Gail Muller Classifieds PO Box 70 - Seattle WA 98111 Other: Was mailed to each of the addresses listed/attached on this 20 day of September in the year 2011 Mailed to applicant and Department of Ecology. Project Name: Verizon Wireless SEAQ PONCHO Project Number: E11-009, PL11-021 Mailing requested by: Jaimie Reavis Mailer's signature: u�;�,y�j'v H:\Wireless Telecommunication Facilities\PL11-021_Verizon_Type 1_SEAQ PONCHO\SEPA\Affidavit of Distribution_E11- 009_NOD.doc City of Tukwila Department of Community Development File Number El 1-009 (SEPA) L11-028 (Wireless Permit) PL11-021 (Project Number for Time Tracking) LAND USE PERMIT ROUTING FORM TO: 1E1 Building Planning OPublic Works Oire Dept. Police Dept. Parks/Rec Project: Verizon Wireless — Electrical Transmission Tower at S. 109th St. and Beacon Ave. S. Address: West side of Beacon Ave S north of S. 109th St (parcel #687420-1170) Date transmitted: 08/15/2011 Response requested by: 08/22/2011 Staff coordinator: Jaimie Reavis Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) No C_AINVYlst. 1C1.s —VI NAVt Plan check date: Comments .W151 Update date: \\\�\\ prepared by: TO: City of Tukwila Department of Community Development File Number E11-009 (SEPA) L11-028 (Wireless Permit) PL11-021 (Project Number for Time Tracking) LAND USE PERMIT ROUTING FORM 1[ Building °Planning QPublic Works 10Fire Dept. Police Dept. 101 Parks/Rec Project: Verizon Wireless — Electrical Transmission Tower at S. 109th St. and Beacon Ave. S. Address: West side of Beacon Ave S north of S. 109th St (parcel #687420-1170) Date transmitted: 08/15/2011 Response requested by: 08/22/2011 Staff coordinator: Jaimie Reavis Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) _ MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) Plan check date: Comments Update date: prepared by: City of Tukwila Department of Community Development RECEIVED AUG 15 Z011 ruKWILA PUBLIC WORKS File Number E11-009 (SEPA) L11-028 (Wireless Permit) PL11-021 (Project Number for Time Tracking) LAND USE PERMIT ROUTING FORM TO: Q Building Q Planning l Public Works Fire Dept. Police Dept. Parks/Rec Project: Verizon Wireless — Electrical Transmission Tower at S. 109th St. and Beacon Ave. S. Address: West side of Beacon Ave S north of S. 109th St (parcel #687420-1170) Date transmitted: 08/15/2011 Response requested by: 08/22/2011 Staff coordinator: Jaimie Reavis Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) ?w .►.Q,,.wl t,t w kolLec 4 lr r A r �s't'I w aki P,0,c"' depicted 6 r 14 poet- /teko (339 37.3 (lier'2ot-t. Ul eS-s Plan chec1 date: I Comments Update date: prepared by: J01 r' 8%3 Jf/ City of Tukwila Department of Community Development File Number El 1-009 (SEPA) L11-028 (Wireless Permit) PL11-021 (Project Number for Time Tracking) LAND USE PERMIT ROUTING FORM TO: a3uilding Le Planning QPublic Works Fire Dept. Police Dept. Parks/Rec Project: Verizon Wireless — Electrical Transmission Tower at S. 109th St. and Beacon Ave. S. Address: West side of Beacon Ave S north of S. 109th St (parcel #687420-1170) Date transmitted: 08/15/2011 Response requested by: 08/22/2011 Staff coordinator: Jaimie Reavis Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) ,e4 Plan check date: Comments Update date: —/6 --�" prepared by: City o,Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director August 5, 2011 BILL NORTH The North Group PO Box 2449 Snohomish WA, 98291 RE: VERIZON WIRELESS SEAQ PONCHO Notice of Application, "pit 1_021 % S. 109th Street and Beacon Ave S. Dear Mr. North: okiodu There is a fee due on your permit application in the amount of $117.00 to cover fees associated with mailing the attached public notice. The number of required notices sent for your application was 117 which included property owners and tenants within 500 feet of your project site as well as interested parties and agencies with jurisdiction. The cost is based on the land use fee schedule adopted by Resolution Number 1718 covering Public Notice mailings required for your application. This fee covers the attached notice only. Additional fees may be assessed for future mailings or other review tasks per the `ze schedule. This amount needs to be paid before the city can continue processing your permit application. The payment may be paid by cash, check or credit card. The city will accept credit card payments by phone. If paying by check please send the check made out to: City of Tukwila 6300 Southcenter Blvd, Ste 100 Tukwila, WA 98188 If payment is not received within 15 days of this notice your permit application may be put on hold. If you have any questions, please feel free to contact me at 206 431 3670. Sincerely, Teri Svedahl Administrative Support Technician MD Invoicing Public Mailings.doc Page 1 of 1 08/02/2011 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 Nc3rth SEP1520111 commuND7 DEVEEVELOPNEHT P. O. Box 2449 Snohomish, WA 98291-2449 Phone (425) 876-2909 Fax (425) 671-0862 e-mail: billnorth@northgroup.net Memo Date: G b, To: S Company: From: Bill North Telephone: 425.876.2909 FAX: 425.671.0862 Comments: ccr-T-A_abi-eeV 0,e4 toc`/Iii-r qs �eac.cAvi 6ivc S )orYtJA029 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 6874201170 Permit Number: E11-009 Address: Status: PENDING Suite No: Applied Date: 07/05/2011 Applicant: VERIZON WIRELESS SEAQ PONCHO Issue Date: Receipt No.: R11-02030 Initials: TLS User ID: 1670 Payment Amount: $517.00 Payment Date: 09/16/2011 09:50 AM Balance: $0.00 Payee: KDC ARCHITECTS ENGINEERS FOR VERIZON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6165 517.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MAPS/PUBLIC/MAILING 000.341.500 517.00 Total: $517.00 (40 O ‘74-- C. 6- 5,v1 G*L..kct (oc�A_ 4 l 1 1 •' " i'VkJ;. l,'n QC' k)o k C d , doc: Receiot-06 Printed: 09-16-2011 City Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director August 5, 2011 BILL NORTH The North Group PO Box 2449 Snohomish WA, 98291 RE: VERIZON WIRELESS SEAQ PONCHO Notice of Application, PL11-021 S. 109th Street and Beacon Ave S. Dear Mr. North: There is a fee due on your permit application in the amount of $117.00 to cover fees associated with mailing the attached public notice. The number of required notices sent for your application was 117 which included property owners and tenants within 500 feet of your project site as well as interested parties and agencies with jurisdiction. The cost is based on the land use fee schedule adopted by Resolution Number 1718 covering Public Notice mailings required for your application. This fee covers the attached notice only. Additional fees may be assessed for future mailings or other review tasks per the rye schedule. This amount needs to be paid before the city can continue processing your permit application. The payment may be paid by cash, check or credit card. The city will accept credit card payments by phone. If paying by check please send the check made out to: City of Tukwila 6300 Southcenter Blvd, Ste 100 Tukwila, WA 98188 If payment is not received within 15 days of this notice your permit application may be put on hold. If you have any questions, please feel free to contact me at 206 431 3670. Sincerely, Teri Svedahl Administrative Support Technician MD Invoicing Public Mailings.doc Page 1 of 1 08/02/2011 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 Teri Svedahl From: Sent: To: Subject: Hi Teri, Jaimie Reavis Friday, July 29, 2011 8:59 Teri Svedahl public notice mail I will need addresses generated for a postcard mailing for parcel number 6874201170. The mailing needs to go out by ust 5. I'll get the postcard ready. Jaimie InU l 1 Teri Svedahl From: Jaimie Reavis Sent: Friday, July 29, 2011 10:08 AM To: Teri Svedahl Subject: postcard for mailing - PL11-021, E11-009, L11-028 Verizon Wireless Attachments: E11-009_L11-028_PL11-021_Verizon_S. 109th St&Beacon Ave S.pub Hi Teri, The postcard is attached. Let me know if you have any questions. Thanks! Jaimie City of Tukwila Notice of Application Verizon Wireless Facility Permit SEPA Environmental Review .1 — i .-.--t..-_� = l t. xl y_ =_1 i Project Location Location: Existing electrical transmission north of the intersection of S. 109th St. and Beacon Ave S. (Parcel Number 687420-1170). File Numbers: E11-009 (SEPA), L11-028 (Wireless Facility Permit) Applicant: Bill North, The North Group Property Owner: Seattle City Light Project Planner: Jaimie Reavis, 206-431-3659 Project Description. Replacement of 6 panel antennas on an existing Seattle City Light electrical transmis- sion tower with 12 new panel antennas. Six new ground mounted equipment cabinets are also proposed to be added to the site and screened from view behind a new chain link fence with privacy slats. Comments and Appeals: Tukwila has reviewed the project for probable adverse environmental impacts and expects to issue a determination of non -significance (DNS) under the optional DNS process in WAC 197-11-35. There will be a single integrated comment period for the environmental review so this may be your only oppor- tunity to comment on the environmental impacts of the project. if timely comments do not identify probable significant adverse impacts that were not considered by the anticipated determination the DNS will be issued without a second comment period. Your written comments on the project are requested and can be delivered to DCD, 6300 Southcenter Blvd., Suite 100. Comments must be received by 5:00pm on August 19, 2011. You may request a copy of any decision, information on hearings, and your appeal rights by calling 206- 431-3659. You are receiving this notice because you are a property owner or tenant within 500ft of this project. City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTICE OF COMPLETE APPLICATION July 22, 2011 Mr. Bill North P.O. Box 2449 Snohomish, WA 98291 Subject: Verizon Wireless Communication Facilities Permit at S. 109th Street and Beacon Ave S (parcel #687420-1170) L11-028 (Wireless Permit Number) El 1-009 (SEPA File Number) PL11-021(Land Use Project Number) Dear Mr. North: Your applications for a Wireless Telecommunications Facility permit and SEPA Environmental Review are considered complete on July 22, 2011 for the purposes of meeting state mandated time requirements. This determination of complete application does not preclude the ability of the City to require that you submit additional plans or information, if in our estimation such information is necessary to ensure the project meets the substantive requirements of the City or to complete the review process. This notice of complete application applies only to the permits identified above. A business license application will be required to be submitted to the City of Tukwila prior to approval/issuance of the Wireless Permit. It is your responsibility to apply for and obtain all necessary permits issued by other agencies. Please arrange to have the public notice board for this project manufactured and installed on site within the next 14 days. You will also need to submit a fee of $400.00 to have the City generate mailing labels for the public notice mailing for this project. The City of Tukwila will coordinate the public notice mailing with installation of the public notice board. The public comment period for the Notice of Application will be 14 days for both the wireless facility permit and the SEPA Environmental Review applications. These notice periods will run concurrently. As we have discussed, the City will be processing the SEPA permit under the Optional DNS process. Please feel free to contact me with any questions at (206) 431-3659 or Jaimie.Reavis@TukwilaWA.gov. Sincerely, aomq Jaimie Reavis Assistant Planner �zl 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 6874201170 Address: Suite No: Applicant: NORTH, BILL RECEIPT Permit Number: E 11-009 Status: PENDING Applied Date: 07/05/2011 Issue Date: Receipt No.: R11-01371 Initials: User ID: JR 1659 Payment Amount: $1,490.00 Payment Date: 07/05/2011 11:28 AM Balance: $400.00 Payee: KDC ARCHITECTS ENGINEERS PC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6131 1,490.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts SEPA 000.345.831 1,490.00 Total: $1,490.00 doc: Receiot-06 Printed: 07-05-2011 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail.: tukplan(cci.tukwila.wa.us RECEIVED rJUL' 0'5 20111 COMMUNITY SEPA DEVELOPMENT ENVIRONMENTAL REVIEW APPLICATION FOR STAFF USE ONLY Permits Plus TYPE P-SEPA Planner::Tim, M i f gam ✓ IS' File Number: c. 11 — 0 d 0/ Application Complete (Date: '7J2-- J I /) Project File Number: p f 1— (al 1 Application Incomplete (Date: ) Other File Numbers: (, / / — U 7 g NAME OF PROJECT/DEVELOPMENT: Verizon wireless SEAQ Poncho LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. S. 1'09th Street and Beacon Ave S LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 687420-1170 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City to whom all notices and reports will be sent. Name: Bill North, The North Group Address: PO Box 2449, Snohomish, WA 98291 Phone: 425-876-2909 FAX: 425-671-0862 E-mail: billnorth@northgroup.net Signature: ta id Date: 7—/---// Q:\Department Folders\DCD\DCD Common\Forms\Applications, Land Use\2011 Website\SEPA Environmental Review Application- Jan2011.doc 1 COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing by the Public Works Department and the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning APPLICATION MATERIALS: X 1. Application Checklist (1 copy) indicating items submitted with application. X 2. Completed ESA Screening Checklist, SEPA Environmental Checklist and drawings (5 copies). X 3. One set of all plans reduced to 8 1/2" by 11" or 11" by 17". X 4. Application Fee: See Land Use Fee Schedule. X 5. Underlyingpermit application that triggers SEPA review. PUBLIC NOTICE MATERIALS: N/A 6. Payment of a $365 notice board fee to FastSigns Tukwila or Provide a 4' x 4' public notice board on site within 14 days of the Department determining that a complete application has been received (see Public Notice Sign Specifications Handout). N/A 7. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; Or provide an excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses) within 500 feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos, trailer parks --must be included. Once your project is assigned to a planner, you will be required to provide an electronic copy of the mailing label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these fields as an individual column: Name Street Address City, St, Zip Mr. Smith 1234 Park Ave S Tukwila WA 98188 PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you provide them, there is an additional fee for postage and material as listed under Public Notice Mailing Fee on the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the decision and you will receive a separate bill for this fee. N/A 8. If providing own labels, include King County Assessor's map(s) which shows the location of each property within 500 ft. of the subject lot. PROJECT DESCRIPTION AND ANALYSIS: X 9. Vicinity Map with site location. N/A 10. Provide four (4) copies of any sensitive area studies such as wetland or geotechnical reports if needed per Tukwila's Sensitive Areas Ordinance (TMC 18.45). See the Geotechnical Report Guidelines and Sensitive Area Special Study Guidelines (online at www.ci.tukwila.wa.us/dcd/dcdplan.htm) for additional information. Q:\Department Folders\DCD\DCD Common\Forms\Applications, Land Use\2011 Website\SEPA Environmental Review Application- Jan2011.doc Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning N/A 11. Any drawings needed to describe the proposal other than those submitted with the underlying permit. Maximum size 24" x 36". Q:\Department Folders\DCD\DCD Common\Forms\Applications, Land Use\2011 Website\SEPA Environmental Review Application- Jan2011.doc City of Tukwila Endangered Species Act Screening Checklist July 1, 2010 Date: RECEIVE AUG 15 ZQ11 TUKPI JRLICWWORKS Applicant Name: Street Address: C/o Bill North PO Box 2449 Snohomish, WA 98291 City, State, Zip: Telephone: 425-876-2909 Verizon Wirless Directions This Screening Checklist has been designed to evaluate the potential for your project to result in potential "take" of Chinook salmon, Coho salmon, or Cutthroat trout as defined by Section 9 of the Endangered Species Act. The checklist includes a series of "Yes" or "No" questions about your project, organized into four parts. Starting with Part A on Page 1, read each question carefully, circle "Yes" or "No," and proceed to the next question as directed by the checklist. To answer these questions, you may need to refer to site plans, grading and drainage plans, critical areas studies, or other documents you have prepared for your project. The City will evaluate your responses to determine if "take" is indicated. Q:\Department Folders\DCD\DCD Common\Forms\Applications, Land Use\2011 Website\SEPA Environmental Review Application-Jan2011.doc Part A: Please review and answer each question carefully. Consider all phases of your project including, but not limited to, construction, normal operation, potential emergency operation, and ongoing and scheduled maintenance. Continue to the next question as directed for each No or Yes answer. 1-0 Will the project require any form of grading? Grading is defined as any excavating, filling, clearing, or creation of impervious surface, or any combination thereof, which alters the existing ground surface of the earth (TMC 18.06.370). Please circle appropriate response. NO - Continue to Question 2-0 CDContinue to Question 1-1 (Page 3) 2-0 Will the project require any form of clearing? Clearing means the removal or causing to be removed, through either direct or indirect actions, any vegetation from a site (18.06.145). Please circle appropriate response. NO Continue to Question 3-0 YES - Continue to Question 2-1 (Page 4) 3-0 Will the project require work, during any time of the project, below the ordinary high water mark of a watercourse or the Green/Duwamish or Black Rivers or in wetlands? Ordinary high water mark is the mark that is found by examining the bed and banks of a stream and ascertaining where the presence and action of waters are so common and usual as to distinctly mark the soil from that of the abutting upland, in respect to vegetation (see TMC Chapter 18.06, Pay a 18-15). Please circle appropriate response. NO - ontinue to Question 4-0 YES - Continue to Question 3-1 (Page 5) 4-0 Will the project result in the processing or handling, storage, or treatment of hazardous substances? This does not include the proper use of fuel stored in a vehicle's fuel tank. Hazardous substances are any liquid, solid, gas, or sludge, including any material, substance, product, commodity, or waste, regardless of quantity, that exhibits the characteristics or criteria of hazardous waste as defined by Washington Administrative Code 173-303 (TMC 18.06.385). This includes fuel or other chemicals stored on -site during construction. Please circle . 4 s ropriate response. NO Continue to Question 5-0 YES - Continue to Question 5-0 5-0 Will the project result in the withdrawal, injection, or interception of groundwater? Examples of projects that may affect groundwater include, but are not limited to: construction of a new well, change in water withdrawals from an existing well, projects involving prolonged construction dewatering, projects installing French drains or interceptor trenches, and sewer lines. For the purpose of this analysis, projects that require a geotechnical report pursuant to the requirements of TMC 18.45.060 or would require a geotechnical report if not exempt should answer Yes. Please circle appropriate response. NO Continue to Question 6-0 YES - Continue to Question 6-0 Q:\Department Folders\DCD\DCD Common \ Forms \ Applications, Land Use\2011 Website\SEPA Environmental Review Application-Jan2011.doc City of Tukwila ESA Screening Checklist Part A (continued) 6-0 Will the project involve landscaping or re -occurring outdoor maintenance that includes the regular use of fertilizers, pesticides, or herbicides? This does not include the one-time use of transplant fertilizers. Landscaping means natural vegetation such as trees, shrubs, groundcover, and other landscape materials arranged in a manner to produce an aesthetic effect appropriate for the use of the land (TMC 18.06.490). For the purpose of this analysis, this includes the blishment of new lawn or grass. Please circle appropriate response. Checklist Complete YES — Checklist Complete Part B: Please answer each question below for projects that include grading. Review each question carefully, considering all phases of your project including, but not limited to construction, normal operation, potential emergency operation, and ongoing and scheduled maintenance. Continue to the next question as directed for each No or Yes answer. 1-1 Will the project involve the modification of a watercourse bank or bank of the Green/Duwamish or Black Rivers between the ordinary high water mark and top of bank? This includes any projects that will require grading on any slope leading to a river or stream, but will not require work below the ordinary high water mark. Work below the ordinary high water mark is covered in Part C. Please circle appropriate response. Continue to Question 1-2 YES - Continue to Question 1-2 1-2 Could the construction, operation, or maintenance of the project result in sediment transport off site or increased rates of erosion and/or sedimentation in watercourses, the Green/Duwamish rivers, or the Black River? Most projects that involve grading have the potential to result in increased erosion and/or sedimentation as a result of disturbances to the soil or earth. If your project involves grading and you have not prepared a Temporary Erosion and Sedimentation Control Plan specifically designed to retain 100 percent of the runoff (including during construction) from impervious surface or disturbed soils, answer Yes to this question. If your project is normally exempt under the Tukwila Municipal Code and would not require the preparation of a Temporary Erosion and Sedimentation Control Plan, BUT may still result in erosion or sediment transport off site or beyond the work area, answer Yes to this question. Please circle appropriate response. Continue to Question 1-3 YES - Continue to Question 1-3 1-3 Will the project result in the construction of new impervious surfaces? Impervious surfaces include those hard surfaces which prevent or restrict the entry of water into the soil in the manner that such water entered the soils under natural conditions prior to development; or a hard surface area that causes water to run off the surface in greater quantity or at an increased rate of flow from the flow presented under natural conditions prior to development. Such areas include, but are not limited to, rooftops, asphalt or concrete paving, compacted surfaces, or other surfaces that similarly affect the natural infiltration or runoff patterns existing prior to development (TMC 18.06.445). Please circle appropriate response. NO - Continue to Question 2-0 (Page 2) Continue to Question 1-4 Part B (continued) City of Tukwila ESA Screening Checklist 1-4 Will your project generate stormwater from the creation of impervious surfaces that will not be infiltrated on site? For the purpose of this analysis, infiltration includes the use of a stormwater treatment and management system intended to contain all stormwater on site by allowing it to seep into pervious surface or through other means to be introduced into the ground. If your project involves the construction of impervious surface and does not include the design of a stormwater management system specifically designed to infiltrate stormwater, answer Yes to this question. Please circle appropriate response. Continue to Question 2-0 (Page 2) YES - Continue to Question 2-0 (Page 2) Part C: Please review each question below for projects that include clearing. Review each question carefully, considering all phases of your project including, but not limited to construction, normal operation, potential emergency operation, and ongoing and scheduled maintenance. Continue to the next question as directed for each No or Yes answer. 2-1 Will the project involve clearing within 200 feet of the ordinary high water mark of a watercourse or the Green/Duwamish or Black Rivers? Please circle appropriate response. NO Continue to Question 3-0 (Page 2) YES - Continue to Question 2-2 2-2 Will the project involve clearing of any trees within 200 feet of the ordinary high water mark of a watercourse or the Green/Duwamish or Black Rivers? A tree is defined by TMC 18.06.845 as any self-supporting woody plant, characterized by one main trunk, with a potential diameter - breast -height of 2 inches or more and potential minimum height of 10 feet. Please circle a I • ropriate response. NO - Continue to Question 2-3 YES - Continue to Question 2-3 2-3 Will the project involve clearing of any evergreen trees from within 200 feet of the ordinary high water mark of a watercourse or the Green/Duwamish or Black Rivers? For the purpose of this analysis evergreen means any tree that does not regularly lose all its leaves or needles in the f. Please circle appropriate response. NO Continue to Question 2-4 YES - Continue to Question 2-4 2-4 Will the project involve clearing within 100 feet of the ordinary high water mark of a ,tercourse or the Green/Duwamish or Black Rivers? Please circle appropriate response. NO Continue to Question 3-0 (Page 1) YES - Continue to Question 2-5 2-5 Will the project involve clearing within 40 feet of the ordinary high water mark of a watercourse or the Green/Duwamish or Black Rivers? Please circle appropriate response. NO - ontinue to Question 3-0 (Page 2) YES - Continue to Question 3-0 (Page 2) City of Tukwila Esf-i Screening Checklist Part D: Please review each question below for projects that include work below the ordinary high water mark of watercourses or the Duwamish/Green or Black Rivers or in wetlands. Review each question carefully, considering all phases of your project including, but not limited to, construction, normal operation, potential emergency operation, and ongoing and scheduled maintenance. Continue to the next question as directed for each No or Yes answer. 3-1 Will the project involve the direct alteration of the channel or bed of a watercourse, the Green/Duwamish rivers, or Black River? For the purpose of this analysis, channel means the area between the ordinary high water mark of both banks of a stream, and bed means the stream bottom substrates, typically within the normal wetted -width of a stream. This includes both t- is sorary and permanent modifications. Please circle appropriate response. NO Continue to Question 3-2 YES - Continue to Question 3-2 3-2 Will the project involve any physical alteration to a watercourse or wetland connected to the Green/Duwamish River? For the purpose of this analysis, "connected to the river means" flowing into via a surface connection or culvert, or having other physical characteristics that allow for access by salmonids. This includes impacts to areas such as sloughs, side channels, remnant oxbows, ditches formed from channelized portions of natural watercourses or any area that may provide off channel rearing habitat for juvenile fish from the Duwamish River. This includes both temporary construction alterations and permanent modifications. Watercourses or wetlands draining to the Green/Duwamish River that have a hanging culvert, culvert with a flap gate, diversion, or any entirely man-made or artificial structure that precludes fish access s .uld answer Yes to this question. Please circle appropriate response. NO Continue to Question 3-3 YES - Continue to Question 3-3 3-3 Will the project result in the construction of a new structure or hydraulic condition that could be a barrier to salmonid passage within the watercourse or the Green/Duwamish or Black Rivers? For the purpose of this analysis, a barrier means any artificial or human modified structure or hydraulic condition that inhibits the natural upstream or downstream movement of salmonids, • uding both juveniles and adults. Please circle appropriate response. NO Continue to Question 3-4 YES - Continue to Question 3-4 3-4 Will the project involve a temporary or permanent change in the cross -sectional area of a watercourse or the Green/Duwamish or Black Rivers? For the purpose of this analysis, the cross -sectional area is defined as a profile taken from the ordinary high water mark on the right b. i k to the ordinary high water mark on the left bank. Please circle appropriate response. NO - Continue to Question 3-5 YES - Continue to Question 3-5 3-5 Will the project require the removal of debris from within the ordinary high water mark of a watercourse or the Green/Duwamish or Black Rivers? For the purpose of this analysis, debris includes, but is not limited to fallen trees, logs, shrubs, rocks, piles, rip -rap, submerged metal, and broken concrete or other building materials. Projects that would require debris removal from a watercourse or the Green/Duwamish or Black Rivers as part of a maintenance activity should answer Yes to this question. Please circle appropriate response. NO Continue to Question 3-6 YES - Continue to Question 3-6 3-6 Will the project result in impacts to watercourses or wetlands that have a surface connection to City of Tukwila ESA Screening Checklist another watercourse or the Green/Duwamish or Black Rivers but do not contain habitat conditions that support salmonid use? Such areas may include, but not be limited to hillside seeps and wetlands isolated from the watercourse or river that have a surface water connection to the watercourse or river but are not assessable, nor would be assessable to salmonids under natural conditions. Wetlands with a "functions and values" rating for baseflow/groundwater support of 9 and above (or moderate) as described in Cooke (1996) should be included. Please c cle appropriate response. Continue to Question 3-7 YES - Continue to Question 3-7 3-7 Will the project include the construction of artificial waterways or wetlands connected to a watercourse containing salmonids? For the purpose of this analysis, the construction of artificial waterways or wetlands includes wetlands, channels, sloughs, or other habitat feature created to enhance wildlife use, particularly waterfowl use, or may be attractive to wildlife, cularly waterfowl. Please circle appropriate response. Continue to Question 3-8 YES - Continue to Question 3-8 3-8 Will the project include bank stabilization? For the purpose of this analysis, bank stabilization includes, but is not limited to, rip -rap, rock, log, soil, or vegetated revetments, concrete structures, or similar structures. Please circle appropriate response. Continue to Question 4-0 (Page 2) YES - Continue to Question 4-0 (Page 2) RECEIVED IL 0 5 20111 STATE ENVIRONMENTAL POLICY ACT CHECKLIT Please respond to all questions. Use separate sheets as necessary. Applicant Responses: A. BACKGROUND 1. Name of proposed project, if applicable: SEAQ Poncho 2. Name of Applicant: Verizon Wireless 3. Date checklist prepared: July 1, 2011 4. Agency requesting checklist: City of Tukwila 5. Proposed timing or schedule (including phasing, if applicable): Construction 2011/ no phasing 6. Do you have any plans for future additions, expansion, or further activity related to or connected with this proposal? If yes, explain. None 7. List any environmental information you know about that has been prepared, or will be prepared, directly related to this proposal. SEPA determination 8. Do you know whether applications are pending for governmental approvals of other proposals directly affecting the property covered by your proposal? If yes, explain. No Agency Comments RECEIVED AUG 15 2011 TUKWILA PUBLIC WORKS Q:\Department Folders\DCD\DCD Common \ Forms \ Applications, Land Use\2011 Website\SEPA Environmental Review Application-Jan2011.doc Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 9. List any government approvals or permits that will be needed for your proposal. Building Permit 10. Give brief, complete description of your proposal, including the proposed uses and the size of the project and site. There are several questions later in this checklist that ask you to describe certain aspects of your proposal. You do not need to repeat those answers on this page. This unmanned communication facility for the transmission and reception of wireless communications will include twelve (12) wireless panel antenna mounted upon a 131' SCL transmission tower at approx 50' along with ground mounted equipment cabinets with perimeter slatted fencing. 11. Location of the proposal. Give sufficient information for a person to understand the precise location of your proposed project, including a street address, if any, the tax lot number, and section, township, and range. If a proposal would occur over a range of area, provide the range or boundaries of the site(s). Provide a legal description, site plan, vicinity map, and topographic map, if reasonably available. While you should submit any plans required by the agency, you are not required to duplicate maps or detailed plans submitted with any permit applications related to this checklist. S 109th St. & Beacon Ave. S. Tukwila, WA 98188 APN: 687420-1170 Legal:Pottery Works Add C of S Tran LN R/W Over Add 12. Does the proposal lie within an area designated on the City's Comprehensive Land Use Policy Plan Map as environmentally sensitive? No Please respond to all questions. Use separate sheets as necessary. Applicant Responses: B. ENVIRONMENTAL ELEMENTS 1. Earth a. General description of the site (circle one): Flat, rolling, hilly, steep slopes, mountainous, other: Flat Agency Comments b. What is the steepest slope on the site (approximate percent slope)? The project will be located upon a generally flat area c. What general types of soils are found on the site (for example, clay, sand, gravel, peat, muck)? If you know the classification of agricultural soils, specify them and note any prime farmland. This site is an existing electric transmission tower parcel. Soils found are generally sandy loam, clay, gravel, and rock. d. Are there surface indications or history of unstable soils in the immediate vicinity? If so, describe. No e. Describe the purpose, type, and approximate quantities of any filling or grading proposed. Indicate source of fill. Minimal soil grading for the equipment cabinet slab upon smooth, level terrain Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments f. Could erosion occur as a result of clearing, construction, or use? If so, generally describe. No g. About what percent of the site will be covered with impervious surfaces after project construction (for example, asphalt or buildings)? Approximately .0030 h. Proposed measures to reduce or control erosion, or other impacts to the earth, if any: Not applicable 2. Air a. What types of emissions to the air would result from the proposal (for example, dust, automobile odors, industrial wood smoke) during construction and when the project is completed? If any, generally describe and give approximate quantities if known. Temporary minor emissions will result during construction. Upon completion, normal vehicular traffic emissions will occur as a result of monthly maintenance visits to the facility. There will be no air emissions from the site as a result of the operations of the communications facility. b. Are there any off -site sources of emissions or odor that may affect your proposal? If so, generally describe. None known Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments c. Proposed measures to reduce or control emissions or other impacts to air, if any: No emissions will be generated. 3. Water a. Surface: 1. Is there any surface water body on or in the immediate vicinity of the site (including year-round and seasonal streams, saltwater, lakes, ponds, wetlands)? If yes, describe type and provide names. If appropriate, state what stream or river it flows into. No 2. Will the project require any work over, in, or adjacent to (within 200 feet) the described waters? If yes, please describe and attach available plans. No 3. Estimate the amount of fill and dredge material that would be placed in or removed from surface water or wetlands and indicate the area of the site that would be affected. Indicate the source of fill material. Not applicable Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 4. Will the proposal require surface water withdrawals or diversions? Give general description, purpose, and approximate quantities, if known. No 5. Does the proposal lie within a 100-year floodplain? If so, note location on the site plan. No 6. Does the proposal involve any discharges of waste materials to surface waters? If so, describe the type of waste and anticipated volume of discharge. No b. Ground: 1. Will ground water be withdrawn, or will water be discharged to ground water? Give general description, purpose, and approximate quantities, if known. No Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 2. Describe waste materials that will be discharged into the ground from septic tanks or other sources, if any (for example: Domestic sewage; industrial, containing the following chemicals...; agricultural; etc). Describe the general size of the system, the number of such systems, the number of houses to be served (if applicable), or the number of animals or humans the system(s) are expected to serve: No waste material will be generated or discharged at this site. c. Water Runoff (including storm water): 1. Describe the source of runoff (including storm water) and method of collection and disposal, if any (include quantities, if known). Where will this water flow? Will this water flow? Will this water flow into other waters? If so, describe. No runoff associated with this project will occur 2. Could waste materials enter ground or surface waters? If so, generally describe. No waste materials will be generated on the proposed site. d. Proposed measures to reduce or control surface, ground, and runoff water impacts, if any: There will be no significant surface ground water or runoff water impact associated with this project. Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 4. Plants a. Check or circle types of vegetation found on the site: Deciduous tree: alder, maple, aspen, other Evergreen tree: fir, cedar, pine, other Shrubs Grass re Crop or grain Wet soil plants: cattail, buttercup, bulrush, skunk cabbage, other Water plants: water lily, eelgrass, milfoil, other Other types of vegetation b. What kind and amount of vegetation will be removed or altered? No vegetation will be removed. c. List threatened or endangered species known to be on or near the site. None known d. Proposed landscaping, use of native plants, or other measures to preserve or enhance vegetation on the site, if any: No landscaping is proposed. Existing property vegetation will be retained. Please respond to all questions. Use separate sheets as necessary. Applicant Responses: 5. Animals a. Circle any birds or animals which have been observed on or near the site or are known to be on or near the site: Birds: Hawk, heron, eagle, on birds other: Mammals Deer, bear, elk, beaver, Fish Bass, salmon, trout, herring, shellfish, other: Other b. List any threatened or endangered species known to be on or near the site. None known c. Is the site part of a migration route? If so, explain. Not known d. Proposed measures to preserve or enhance wildlife, if any: Not applicable 6. Energy and Natural Resources a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to meet the completed project's energy needs? Describe whether it will be used for heating, manufacturing, etc. Electrical and Telephone service. Agency Comments Electricity will be used to operate the radio equipment. Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments b. Would your project affect the potential use of solar energy by adjacent properties? If so, generally describe. No c. What kinds of energy conservation features are included in the plans of this proposal? List other proposed measures to reduce or control energy impacts, if any: None 7. Environmental Health a. Are there any environmental health hazards, including exposure to toxic chemicals, risk of fire and explosion, spill, or hazardous waste, that could occur as a result of this proposal? If so, describe. No 1. Describe special emergency services that might be required. None required 2. Proposed measures to reduce or control environmental health hazards, if any: The Federal Communications Commission regulates all radio frequency emissions. Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments b. Noise 1. What types of noise exist in the area which may affect your project (for example: traffic, equipment, operation, other)? None. Ambient noise will not affect this project. 2. What types and levels of noise would be created by or associated with the project on a short-term or long-term basis (for example: traffic, construction, operation, other)? Indicate what hours noise would come from the site. There will be some traffic and construction noise associated with the installation of the facility during the 2 - 3 weeks of construction. There may be minimal noise associated with monthly service visits. 3. Proposed measures to reduce or control noise impacts, if any: Minimal, temporary increased noise levels during construction phase are restricted to the hours permitted by city ordinance 8. Land and Shoreline Use a. What is the current use of the site and adjacent properties? The Site is an electrical transmission tower with existing wireless communication facilities. Residential uses are adjacent to the property. b. Has the site been used for agriculture? If so, describe. Not known Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments c. Describe any structures on the site. Electrical transmission towers d. Will any structures be demolished? If so, what? No e. What is the current zoning classification of the site? Residential f. What is the current comprehensive plan designation of the site? Residential g. If applicable, what is the current shoreline master program designation of the site? Not applicable h. Has any part of the site been classified as an "environmentally sensitive" area? If so, specify. Not known Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments i. Approximately how many people would reside or work in the completed project? None J• Approximately how many people would the completed project displace? None k. Proposed measures to avoid or reduce displacement impacts, if any: No displacement or other impacts are anticipated; therefore no mitigation proposal is necessary. 1. Proposed measures to ensure the proposal is compatible with existing and projected land uses and plans, if any: The project design will comply with City of Tukwila codes and ordinances. The antenna will be placed on an existing SCL transmission tower with existing Wireless Communications facilities thereby minimizing visual impact. No new use is proposed. 9. Housing a. Approximately how many units would be provided, if any? Indicate whether high, middle, or low-income housing? None included in this proposal Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments i. Approximately how many people would reside or work in the completed project? None j. Approximately how many people would the completed project displace? None k. Proposed measures to avoid or reduce displacement impacts, if any: No displacement or other impacts are anticipated; therefore no mitigation proposal is necessary. 1. Proposed measures to ensure the proposal is compatible with existing and projected land uses and plans, if any: The project design will comply with City of Tukwila codes and ordinances. The antenna will be placed on an existing SCL transmission tower with existing Wireless Communications facilities thereby minimizing visual impact. No new use is proposed. 9. Housing a. Approximately how many units would be provided, if any? Indicate whether high, middle, or low-income housing? None included in this proposal Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 11. Light and Glare a. What type of light or glare will the proposal produce? What time of day would it mainly occur? None b. Could light or glare from the finished project be a safety hazard or interfere with views? No c. What existing off -site sources of light or glare may affect your proposal? None d. Proposed measures to reduce or control light and glare impacts, if any: None are anticipated 12. Recreation a. What designed and informal recreational opportunities are in the immediate vicinity? The site will not affect recreational opportunities. Please respond to all questions. Use separate sheets as necessary. Applicant Responses: b. Would the proposed project displace any existing recreational uses? If so, describe. No c. Proposed measures to reduce or control impacts on recreation, including recreation opportunities to be provided by the project or applicant, if any: Not applicable 13. Historic and Cultural Preservation a. Are there any places or objects listed on, or proposed for, National, State, or Local preservation registers known to be on or next to the site? If so, generally describe. None known b. Generally describe any landmarks or evidence of historic, archaeological, scientific, or cultural importance known to be on or next to the site. None known c. Proposed measures to reduce or control impacts, if any: Not applicable Agency Comments Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 14. Transportation a. Identify public streets and highways serving the site, and describe proposed access to the existing street system. Show on site plans, if any. The entrance to the project will be from Beacon Ave S b. Is the site currently served by public transit? If not, what is the approximate distance to the nearest transit stop? Not applicable c. How many parking spaces would the completed project have? How many would the project eliminate? No parking spaces will be eliminated. Occasional maintenance personnel will utilize on street parking. d. Will the proposal require any new roads or streets, or improvements to existing roads or streets, not including driveways? If so, generally describe (indicate whether public or private). No e. Will the project use (or occur in the immediate vicinity of) water, rail, or air transportation? If so, generally describe. No Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments f. How many vehicular trips per day would be generated by the completed project? If known, indicate when peak volumes would occur. One vehicle monthly g. Proposed measures to reduce or control transportation impacts, if any: None are necessary 15. Public Services a. Would the project result in an increased need for public services (for example: fire protection, police protection, health care, schools, other)? If so, generally describe. No. The site is unmanned. There is no increased need for public services beyond those which are already provided. b. Proposed measures to reduce or control direct impacts on public services, if any. None 16. Utilities a. Circle utilities currently available at the site: natural gas, ater, , efuse service, septic • Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments b. Describe the utilities that are proposed for the project, the utility providing the service, and the general construction activities on the site or in the immediate vicinity which might be needed. Qwest PSE (NON -PROJECT PROPOSALS (E.G., SUBURBAN PLANS AND ZONING CODE TEXT CHANGES) MUST COMPLETE THE FOLLOWING PAGES). C. SUPPLEMENTAL SHEET FOR NON -PROJECT PROPOSALS (do not use this sheet for project actions) Because these questions are very general, it may be helpful to read them in conjunction with the list of elements of the environment. When answering these questions, be aware of the extent the proposal, or the types of activities likely to result from the proposal, would affect the item at a greater intensity or at a faster rate than if the proposal were not implemented. Respond briefly and in general terms. Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 1. How would the proposals be likely to increase discharge to water; emissions to air; production, storage, or release of toxic or hazardous substances; or production of noise? Proposed measures to avoid or reduce such increases are: Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Agency Comments 2. How would the proposal be likely to affect plants, animals, fish, or marine life? Proposed measures to protect or conserve plants, animals, fish, or marine life are: 3. How would the proposal be likely to deplete energy or natural resources? Proposed measures to protect or conserve energy and natural resources are: 4. How would the proposal be likely to use or affect environmentally sensitive areas or areas designated (or eligible or under study) for governmental protection; such as parks, wilderness, wild and scenic rivers, threatened or endangered species habitats, historic or cultural sites, wetlands, floodplains, or prime farmlands? f Please respond to all questions. Use separate sheets as necessary. Applicant Responses: Proposed measures to protect such resources or to avoid or reduce impacts are: 5. How would the proposal be likely to affect land and shoreline use, including whether it would allow or encourage land or shoreline uses incompatible with existing plans? Proposed measures to avoid or reduce shoreline and land use impacts are: 6. How would the proposal be likely to increase demands on transportation or public service and utilities? Proposed measures to reduce or respond to such demand(s) are: Agency Comments 4 Please respond to all questions. Use separate sheets as necessary. Applicant Responses: 7. Identify, if possible, whether the proposal may conflict with Local, State, or Federal laws or requirements for the protection of the environment. D. SIGNATURE Under the penalty of perjury the above answers under ESA Screening Checklist and State Environmental Policy Act Checklist are true and complete to the best of my knowledge. I understand that the lead agency is relying on them to make its decision. Signature: Date Submitted: ctc i()2 Agency Comments Application for Wireless Communications Facility VERIZON WIRELESS SEAQ Poncho A Proposal Submitted to City of Tukwila Prepared for Verizon Wireless 15900 SE Eastgate Way Bellevue, WA 98008 Prepared by The North Group, Inc. Bill North PO Box 2449 Snohomish, WA 98291 April 20, 2011 RECEIVED AUG 15 2011 TUKWILA. PUBLIC WORKS 1 • I. PROPOSAL SUMMARY INFORMATION Verizon Wireless Site: SEAQ Poncho Applicant: Prepared By: Verizon Wireless 15900 SE Eastgate Way Bellevue, WA 98008 The North Group, Inc. Bill North PO Box 2449 Snohomish, WA 98291 425-876-2909 billnorth a(�northgroup.net Property Owner: Seattle City Light Request: Site Location: Assessors Parcel Number: S= . APR 21 2011 Approval of a Type I Wireless Facilities Permit and Building Permit for a Wireless Communication Facility. S. 109th St. and Beacon Ave. S. Tukwila, WA 98188 687420-1170 Zoning: LDR Low Density Residential 2 II. INTRODUCTION Verizon Wireless ("Verizon Wireless") is a wireless communications company operating in City of Tukwila, Washington. Verizon Wireless is licensed to operate in the State of Washington by the Federal Communications Commission (FCC). Verizon Wireless is currently designing its network in Washington to improve its wireless communication service and provide wireless capacity to its subscribers. This proposal describes the scope of the proposed project by providing specific information regarding the project location, zoning, specifications, and response to City of Tukwila code requirements pertaining to Wireless Communications Facilities (WCF). It is Verizon Wireless's desire to work with City of Tukwila to ensure that our project is consistent with local ordinances and zoning regulations while providing the wireless communications coverage that is critical for emergency, business, and personal use. Project Goals The goal of the Verizon Wireless Facility is to provide wireless communications coverage for personal and emergency purposes in the immediate area of the project and vicinity. Verizon Wireless intends to achieve these network goals consistent with all policies and ordinances of City of Tukwila. Application Request The applicant is requesting the following: Approval of a Type I Wireless Facilities Permit and Building Permit for a Wireless Communication Facility. III. PROJECT DESCRIPTION Project Overview Verizon Wireless, the applicant is proposing to replace 6 panel antennas on an existing Seattle City Light (SCL) electrical transmission tower with 12 new panel antennas along with the addition of 6 ground mounted equipment cabinets. The existing SCL tower is located at S. 109'h St. and Beacon Ave. S. Tukwila, WA 98188 and identified as A.P.N. # 687420-1170. The equipment cabinets will be placed below the tower and will include perimeter fencing. Zoning General Plan Designation The site is located on property zoned LDR Low Density Residential. The City of Tukwila code references Wireless Communications Facilities in TMC Chapter 18.58. The proposal is classified as an "Electrical Transmission Tower Co -Location" (18.58.080). This proposal is permitted with a Type I Wireless Facilities Permit and Building Permit. Existing Use 3 Seattle City Light Electrical Transmission Tower with existing Wireless Communication Facilities. Traffic There are no traffic impacts associated with these types of facilities as they are unmanned and require infrequent maintenance. A parking area is provided. FCC/FAA Verizon Wireless is licensed to operate in the State of Washington by the Federal Communications Commission (FCC). Verizon Wireless will conform to all FAA/FCC regulations as well as all other applicable federal, state, and local laws, rules, and regulations. Please see attached FCC license. IV. City of Tukwila Wireless Communication Facility Design Standards Section 18.58.080 of City of Tukwila code has specific requirements for wireless communication facilities located on transmission towers. The following addresses each of the requirements in the order they appear: 1. Height — There is no height requirement for antennas that are located on electrical transmission towers. Response: The antennas will be located on the tower at approximately 50'. No height increase is proposed. 2. Antenna aesthetics- There are no restrictions on the type of antennas located on the electrical transmission tower. The antennas must be painted to match the color of the electrical transmission tower. Response: The attached antennas will be painted to match the color of the tower in compliance with this section. 3. Antenna aesthetics— There is no limit on the number of antennas that may be located on an electrical transmission tower structure. Response: Verizon proposes to locate 12 antennas on the tower. 4. Feed lines and coaxial cables— shall be attached to one of the legs of the electrical transmission tower. The feed lines and cables must be painted to match the color of the electrical transmission tower. Response: Verizon will place 18 coaxial cable on one leg and paint to match the color of the electrical transmission tower. 5. Cabinet equipment— Cabinet equipment shall be located directly under the electrical transmission tower where the antennas are located or a concealed location. The wireless communication equipment compound shall be fenced; the fence shall have a minimum height of 6 feet and a maximum height of 8 feet. The fence shall include 4 slats, wood panels, or other materials to screen the equipment from view. Barbed wire may be used in a utility right-of-way that is not zoned residential. Response: The equipment cabinets will be placed below the tower within a 20'x30' fenced area with privacy slats. 6. Setbacks— Since the facility will be located on an existing electrical transmission tower, setbacks shall not apply. Response: Not applicable. Summary: The proposed Verizon Wireless Communication Facility meets the requirements of the City of Tukwila Code 18.58.080. We appreciate the opportunity to make our proposal and to provide quality wireless communication services to the residents of the City of Tukwila. Sincerely, Bill North The North Group, Inc on behalf of Verizon Wireless. 5 SHEET INDEX ARCHITECTI IRA! 1-1 TITLE SHEET A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN & PROPOSED ANTENNA LAYOUT A-3 NORTH & EAST ELEVATIONS A-3.1 SOUTH & WEST ELEVATIONS S pEr0/S, A-6 DETAILS A PI FCTRICAI E-1 ONE LINE DIAGRAM, ELECTRICAL NOTES E-2 ELECTRICAL SITE PLAN E-3 ELECTRICAL GROUNDING PLANS (SCHEMATIC) E-4 DETAILS ROJECT DIRECTORY PI (CANT VERIZON WIRELESS 15900 SE EASTGATE WAY M/S 231 BELLEVUE, WA 98008 APPI (CANT AGENT. ROC ARCHIIECTS, ENGINEERS P.C. 4720 200TH STREET SW., SUITE 200 LYNNWOOD, WA 96036 CONTACT: BILL NORTH PHONE: (425) 876-2909 FAX: (425) 671-0862 ARCHITECT/ELECTRICAL ENGINEER. KDC ARCHITECTS, ENGINEERS P.C. 4720 200TH STREET SW., SUITE 200 LYNNWOOD, WA 98036 CONTACT: ERIC CAMP PHONE: (425) 67C-8651 FAX: (425) 712-0846 PROJECT INFORMATION y/ASHINGTON STATE CODE COMPLIANCE: 2009 IBC, STANDARDS AND AMENDMENTS-WAC 51-50; 2009 IMC, STANDARDS AND AMENDMENTS-WAC 51-52, 2009 AFC, STANDARDS AND AMENDMENTS -WAG 51-54; 2009 IPC, STANDARDS AND AMENDMENTS-WAC 51-56, 51-57. SITE NAMF- SEAO—PONCHO ADDRESS' .09TH & BEACON AVE S. .WILA, WA 98178 WO OWNER' SEATTLE CITY LIGHT 3613 4TH AVE. 5.. S-7 SEATTLE, WA 98134 PHONE: (206) 733-9138 JURISDICTION. CITY OF TUKWILA PARCFL NUMBER' 687420-1170 PROJECT DESCRIPTION' THIS PROPOSAL 'S FOR THE INSTALLATION OF (6) VERIZON WIRELESS 0::TD00R EOJIPMENT CABINETS MOUNTED ON A CONCRETE PAD WITHIN A 20'-0" X 30'•-0" FENCED LEASE AREA. ALSO THE ADDITION OF (12) VERIZON WIRELESS ANTENNAS MOUNTED AT AN EXISTING 125'-A"* HIGH TRANSMISSION TOWER. RECEIVED JUL 0 5 2011 COMMUNITY DEVELOPMENT 1/e/'1n1'lwireless SEAQ-PONCHO 10581 BEACON AVE S SEATTLE, WA 98178 SCL TOWER#: DU 2/7S LAT: 47° 30' 21.32"N LONG: 122° 16' 14.38"W ELEV: 278.6' AMSL LEGAL DESCRIPTION PON WOMBS Am c or s num 1.N RM %i0 ADO CONTRACTOR NOTE o6L� E"vE µors HE GBN,R EE THE ORAN.. AND OR SPECIFICATIONS SHALL NOT EXCUSE SNO CONTRACTOR LIPROVEmENTS IN ACCORDANCE WITH NE OF WIESE OCCRmEXIS THE ENDDER SHAM. BEAR TXE RESPONS1BIUFT OF HOP,. SITE PERSPECTIVE GENERAL NOTES APPROVALS/ISSUE DATES SYMBOLS LIST NOTE0 OTHERWISE. THE CENER, CONTRACTOR'S SCOPE OF WORK SNALL INCLUDE clZ,1121aIrj4L,I.,,,IATAATIRI,Wrtr1IFZIRDIOk.stiA0.130.1r,D ANYTHING ELSE DEEMED NECESSARY MISS IONS. CINEEa IN WFIw . 5 "RE TO BE BROUGHT TO TNN40N OF THEAa_0wr0 RGENROVTKCVNaECErvE 10Mi CFMtr OEnnOME CONSTRUCTION RAw4Ncs/coNIRACT DOCINENr0 wORK UNDER ME CONTRACT. NE CDOES CONTRACTOR s r0KE 7,, EC2 C01107 UNLESS NOTED OTHERWISE OR 4104E 1W4 S. ALL PFORN PERFORMED ON PROJECT AND MATERIALS ALLED SH,A. BE IN STRICT SrKLLWVEEMTN ALL NO�DCES APPLICABLE CONPLY WITH W.'S. OORDINANCCEs R.CiLFS. CONTRACTORREGULATIONS HE B1Fucru"AL c0A ROhCT SOE/FAG OF i0 BE 0._ANTENNA SUPPORTING POLE IS UNDER A SEPARATE CONTRACT. NE CONTRACTOR le 1BE IN ERN1S To SHALL TRA PERSONNEL AND PROPERTY 'Ram LARO.NONS FOR DIE USE EN' ALL PERSONNIL INVOLVED %hi TNE PROJECT. IL,01,,T=1:1C,Ljn HEREIN ARE INTENDED TO SNOW END RESULT OF DESIGN. MINOR FICATIONS SNAIL 11. THE CONTRACTOR SHALLu0,0 A9 ANE NECESSARY PR o OF waNS TO EC T EXISTING IMPROvEMENTS. EASEMENTS. PAWN, CURBINC. ETC. OUR.° CONSTRUCTION UPON 12. CONTRACTOR SW, ENSURE THE GUTERAL wORK AREA KEPT CLEAN AND HA.NRD FREE DURING CONSTRUCTION AND DISPOSE OF A, DIRT. DEB.. RUBBISH AND REMOVE SITE ALPHA N0: DATE ISSUED AS Preliminary Preliminary -Revised Zoning -Special USN Permit Apprcation Construction Permit APPIicouen Issuer) mr ZoninG/Co9strucfi0n Issued to Constructon Issued Zoning & Construction Permit s Built/Retard Set For Owner and Engineering Approval VERIZON WIRELESS CELLULAR DESIGN ENGINEER APPROVAL PRINTED NAME SIGNATURE TITLE DATE VERIZON WIRELESS PROPERTY OWNER APPROVAL PRATED NAME SIGNATURE TITLE DATE ELEVATION NUMBER ID ELECTRIC METER snEEr NURSER (nv 0 11 0100G DETAIL NUmWER SHEET NUMBER _E_E_ _T_1_ I —0—G— GROUND,. [N] NEW [E] EXISTING d1 (nrvvx ::i BACKBOARD RECEPTACLE PaIER OROUNO uTACw04r DRIVING DIRECTIONS FROM SFATAC INTERNATIONAL AIRPORT DEPART SEATTLE-TACOMA INTCRNA1IONAL ARPT-NORTH ENT ON LOCAL ROAD(5) (NORTH-WEST) TAKE RAMP (RIGHT) ONTO SR-51BWA-51O / 1-5 / 1-405 / SGITLE / TACOMA TAKE RAMP (LEFT) ONTO I-51-5 / SEATTLE AT EXT 157, TAKE RAMP (RIGHT) ONTO SR-900 (MARTIN LUTHER KING WAY 5)14 L KING WAY TURN RIGHT (EAST) ONTO 5 RYAN WAY TURN RICHT (SOUTH) ONTO 51ST AVE TURN RIGHT (WEST) ONTO S 109'H ST ARRNE 10581 BEACON AVE S. SEATTLE. WA OBITS CONFIDENTIAL AND PROPRIETARY Not for disclosure outside VERIZON WIRELESS without permission. VICINITY MAP PLANS PREPARED FOR PLANS PREPARED BY WIMP FINN, POW OR — )I )I R (( Ill MIIII ■ II 1 ■■I1 KDC ARCHITECTS.ENGINEERS, P.C. MO zoom STREET SW SURE z00 LYNWNNOO. WA9tl3e ROOK: ..E70.6651 12.08. LICENSURE 5773 REGISTERED ARCHITQCT KENNETH D. CAMP STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPT 8Y .IE /12 ISS0 D FOR 2010 BOX CO RENEW RLD 2/02 ISSUED FOR 2010 CONSTRUCTION BAH 12/21 ISSUED FOR 2010 CONSIRU0REVISED TON 11/19 ISSUED FOR REVISER 2011 CONSTRUCTION BAH I/O' 2011 ISSUED FCR RENTED CONSTRUCTION LO 0e '120 iSSUECi FOR CONSTRUCTION NLWSED 10 PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 T-1 P0.0PCRTYYINE ROPETA UNE - - / OVERALL SITE PLAN SCALE FOR 71.36: EP 50-0 SCALE. 11%, PROPOSED PROJECT AREA SEE e APN. 667420-1170 0 `0' 00' D0.01 25' 75' GENERAL NOTES c; Plc NOTE CAUTION! CAL ORE YOJ DC! BURIED UTILITIES EPIST A THE AR. AND UTILITY INFORMATIONSHOWN MAY NOT BE COMPLETE. CONTACT THE OUTILITY LOCATE SE.RNCE A MINIMUM OP 18 HOURS PRIOR TO CONSTRUCTION1-800-411SSSS FGFNFRAL NOTE, REFER TO T-1 % VA, EON GENERAL NOTES. I 1 I _1.1_0! / - I � o - - ST nl S 109TH 1XU(-021 PLANS PREPARED FOR: ^W• PLANS PREPARED BY: N!s WM' raw N KDC ARCHRECTS.ENGINEERS, P.C. QOO DOOM STRESS SW SUITE BOO LINWOOD. WA MOM PHONE: 4I3.670A661 f700 415.711.00W LICENSURE: 5773 REGISTERED ARC TECT I PO. STATE OF WASHINGT NI DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: FJC REVISIONS OATS 11/17 2010 2/02 170101 01/10 2011 DESCRIPTION BY BSUEO FOR 90% CD RMEW RAT FOR CONSTRUCTION C ON BAH g,gf=""° CSONSiRUC " ED JPM ISSUED CONSTRUCTION �5E0 BAH Q 20111 ISSUED FOR RUSE° 01/20 ISSUED DRR REVISED 2011 ON RLD1 PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A-1 • AIM MEW - - - - PROPEPTY 1 NF 148_90__ 10-10 04 --- u11 9'7I'-1- 10,PROPOSED ANTENNAS t. I i_T -D 'LL -- 1 f APE: 687420-1170 �Eftr{Y 11NE SITE PLAN ISC0E FOR 24.35: 1 20-0. SOME TOR 11217 1 0 20. 40' wal1=71 10' 30' NORTH KEYED NOTES ESTING DIRT ACCESS ROM *DUSTING O.Y. POWER LINES (TYPICAL) OEXISTING URUTY POl£ (01339373) (050IZON WIRELESS P.O.C.) OEXISTING BOLLARD (000CAL) HYDRANT EXSTNG SINGLE 6.FAM Y RESIDENCE OEXISTING BRUSH LINE OEXISTING CRASS AREA (TYPICAL) OPROPOSED VEIb20N TAPELESS U.G. NWER/TELCO ROUTE (APPROX. 30.2) e GENERAL NOTES TITIS IN NOT A FATEP ALL PROPER. SITO 00RIES. OUE ORIENTATION OF TRUE RE E NOR. AND STREET HALF -WIDTHS HAT. BEEN OBTAINED FROM A PARCEL MAP AND E APPROXIMATE. • CAUTIONI G NOT[, BEFORE Y EXIST IN THE AREA ANO UTILITY INFORMATION L1SHORN MAY NOT BB CIOMPLETE. CONTACT THE ONE-GAll UTILITY LOCATE SERVICE A MINI OF 40 HOURS PRIOR 0 CONSTRUCTION. 1-50- 424-5555 POWER/TELCO POWER TO ORIGINATE FROM THE EXISTING UTILITY POLE (01339373). TIEN ROUTE U.G. TO THE PROPOSED N TER/D15CONNCET. LOCATED ON THE VERI20N WIRELESS PROPOSED UTILITY RACE. (APPROX. 30-0.0) TELCO TO ORIGINATE FROM THE EXISTING UTILITY POLE (01339373), 'HEN ROUTE U G. TO TO THE PROPOSED TELCO BOX, LOCATED ON .f PROPOSED VERIZON WRELESS UTILITY RACK. (APPROX. 30 -OTE) CFNFRAL NOTES: REFER TO I -I & 2/A-5 FOR GENERAL NOES. 1X..1Ib 621 PLANS PREPARED FOR: PLANS PREPARED BY: KDC ANCHITECTS.ENGINEERS, P.C. MO 200TX STREET SW SLWE SOO LLNEM NWOOD. WAW fA% : ASS.S70.11SW 435.113AMO LICENSURE: 15773 I REGISTERED I ' ARCHITECT D STATE OF WASHINGT DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE 2002 10 0 1 1 20 DESCRIPTION BY ISSUED FOR 90S CD REVIEW RED ISSUED FOR CONSTRUCTION BAH ISSUED FOR REVISED CONSTRUCTION 21261 01/19 0ISSUED FOR CONSTRUCTION�SEO 1 BAH O1/31 04/04 ISSUED FOR REV15E0 2011 coNsraucnoN CONSTRUCTION SEO RLD, A10 PRO ECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A-1.1 TOE ACCESS GATE U X- ENLARGED SITE PLAN ANTENNA / COAX SCHEDULE SECTOR OUANDTY RP HEIGHT ANT. SZE AZIMUTH n NHS COAX SZE LE 3 NEW 0'-0. D-0" 335' ♦ NEW )/B' - - ♦'-0' 125' 2 NEW )/6-0 'B' 3 NEW - - )/e. CV- .4 'G' NEW - - 230' NEW ]/e - •S NEW 50-0 Er- 0' 230' a NEW ]/' 20-0 1 01110 Ntill unsingesec EASE RU Xd£ FOR 24236: I/O- 1'-0' SCALE F09 1111I: I/O' - 1-0 I 0 4' It GENERAL NOTES ALLSR'OP01 0 BO DIARIES. ORIENTATION OF TRUf N AND STREET HA -WIDTHS HAVE BEfn OBTNNCD FflW q ia% PMCEL MAP PNO ME aPPTROXIMATE. HALF-WIDTHS DIG CALL BEFORE Y0N TT BURIED UTILITIES EXI15i IN THE ARG ANO U INFORMATIOry SNOW.v N T Oi BE COMPLETE. C OVE-CALL U OCATE SERVICE A MINIMUM OF 48 POUFS PRIOR TO CONSTRUCT... 1-D00-424-5555 POWER/TELCO NOTE' POWER TO ORIGINATE FROM THE EXISTING UTILITY POLE 01339323). THEN ROUTE U.G. TO THE PROPOSED METER/ENSCONUCET. LOCA'ED ON THE VEPIZUN WIRELESS PROPOSED UTUTI RACK. (APPROX. 30'-0,) TELCO TO ORIGINATE FROM THE EXISTING UTUTY POLE 01339373), THEN ROUTE U.C. TO TO THE PROPOSED TELCO BOX, LOCATED ON THE PROPOSED ARIZW WIRELESS UTILITY RACK. (APPROX. 30'-0.$) GENERAL NOTES' REFER TO - 2/A-5 FOR GENERAL NOTES. FENCE NOTES. REFER TO 6/A-5 FOR FENCE NOTES KEYED NOTES I A PROPOSED ANTENNA LAYOUT 0 SCALE TOR 2636: I/C• Y-0' SCALE FOR I1011: I/9 • 1'-9' I O EXISTING ACCESS GATE (TYPICAL) OEXISTING UNU1Y RACK Oj EXIST. ICE BRIDGE O%BEAMS OU CONC E0AUDIPMENT CABINET OF OTHERS MOUNTED ON OEXISTING CHAN UVK FENCE W/ PPNACY SLITS © EXIST NO RELOCATED 3'-6 KCESS GATE O EXIST NG 131'-0-1 TALL TRANSMISSION TOWER OEXISTING 3 -6 ACCESS DATE TO BE REL0G1E0 , EXISTNG GRASS AREA t5 PROPOSED VE0ZON WIRELESS 12'-O- DBL. WOE ACCESS GTEe 11 PROPOSED YERNON WIRELESS UTROY RKX W/ NEW DO. SOS. ▪ ETER. DISCONNECT. TELCO SOX. RC AND GENERATOR PLUG 1© PROPOSED VEINZON WIRELESS U.G. POWER/TELCO (SEE A-1.1 FOR CONTINUATION) FCD PROPOSED VER1ZON WIRELESS 6'-0' HIGH CHAIN UNE FENCE W/ P RNACY SCATS OPROPOSED VERIZON WIRELESS C001 ROUTE AT ICEBIRS0E 4C> PROP05E0 VER12ON WIRELESS 10'-0- 0EBRIDGE f�-A Po POSED VEBIZON WIRELESS CAPS ANTENNA MOUN AT !CHROME <> PROPOSED VERIZON WIRELESS OUTDOOR MAPLES, CABINETS (6 TOTAL) WWNIED ON A F-0- X 20'-0. CONC. PAD OPROPOSED VERIZON SRRELE55 ANTENNAS (12 TOTAL, A PER SECTOR) <> PROPOSED VEW20N WIRELESS ANTENNA FRAME 13OUNT (2 101AL) PRO P• • VE1u1• ' LE 5 •• ROUTE CC> PROPOSED VEWZW WTRELE55 2-3/5- X 12'-6' SRFP ARMS TO CONNECT TO TOWER RED (AUX 1'-6' FROM TOWER BRACING JOINTS TYPICAL) PROPOSED VERIZDN WIRELESS ADJUSTABLE SLOPE NMI (3 TOTAL) ® PROPOSED VER1Z0N WIRELESS SECTOR FRAL4E MOUNT PLANS PREPARED FOR: PLANS PREPARED BY: KDC ARCHITFCTS.ENGINEERS. P.C. MD 200TH STEET SW SURE 202 LVNNVIOODA 98036 RIME RISASOARS1 PNC A23.71 . LICENSURE: 5773 4.41.1 KENNETH D. CAMP STATE OF WASHINGT REGISTERED ARCWTECT DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 90%O ECF0RENEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION DAN 12010/21 ISSUED FOR REVISED CONSTRUCTION 020 19 ISSUED FOR MSED CONSTRUCTION DAH 20 I ISSUED FOR REVISED CONSTRUCTION RLD\ 01/20 ISSUED FOR REVISED 2011 CONSTRUCTION NO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVL S. TUKWILA, WA 98178 A-2 • tf T.O. EXISTING ANTENNAS hOf GTNE 6'YRs 6 TRANSMISSION TOWER S'- .BOFrIOF ARM DOT. O ISTWG E MM 11Fx15ilxc 01. of ARM -0 OPOSED VEFn20N WRELESS ANT. `'AvL,T NORTH ELEVATION [SCALE FOR 24.36' 1/B"y 1-0" SCALE FOR 11X17: I/16' • 1 -0.1 12' �2. i�Isry.v ANRANTENNAS c ERs rwlsslon TOWER ,$BOT.TIOE ARH �E%5iaG BOT. E ARM $DGTrc' qRM SL.).. PROPOSED VERIZON WIRELESS ANTENNAS50'-0" 760E/1 }vOL0.NE 0 0 0 0 0 0 0 0 0 ifir �v 7 01'"'",-01144 -- -i, ■1a-a1■ l _-; I. EAST ELEVATION COAR SCALE FOR 21.36: 1/S. 12: 1/16' = I -0 12' 0 0 0 0 co—:0 KEYED NOTES OEXISTING FIRE HYDRANT OEK.STING U1ILII3 POLE (#1339373) (VERIZON WIRELESS P.G.C.) OEX. STING BOLTING MINGAL) OEX,SIINC UDU11 RACK OEXISTING ICE BRIDGE OE%STING OU1000R 73/PHENT CABINET OF OTHERS MOUNTED ON I-eEAHs cN caxc. Ao OE%15TINC CHAIN LINK FENCE W/ PRIVACY SLATS © E%STINC 13,-B-H TALL TRANSMIS90N TOWER (XISTING ANTENNAS OF OTHERS 03PIG6L) 10 PPETER DISCONNECT. TELCO B0%,4LC Alm GENERATORTT RACK NEVI 2PLUG 11 PROPOSED VERIZON WIRELESS 6'-0 WON C1401. UNE FENCE W/ PRIVACY SLATS <C> PROPOSED VERIZON WRELESS 10'-0' .BRIDGE .<> PROPOSED VERIZON WRELESS GPS ANTENNA MOUNTED At ICEBROCC POST O PROPOSED VER1Z0N WRELE55 OUTDOOR EOUIPWENT CABWER (6 TOTAL) 0006600 ON A 6'-0' R 20'-0' CONE. PAD •C> PROPOSED VERIZON WIRELESS ANTENNAS (12 TOTAL. 4 PER SECTOR) • PROPOSED VERIZON WIRELESS ANTENNA FRAME MOUNT (3 TOTAL) 0 <> PROPOSED VERIZON WIRELESS 2-3/9" X 12'-6 511GE ARMS TO CONNECT TO TOWER LEG (PAS 1'-G. PROM TOWER BRACING JOINTS: 11PICAL) GENERAL NOTES FENCE NOTE' E%ISRNG AND PROPOSED CHAN LANK FENCE SHOWN AS DASHED LINE FOR CWOTY. PANT 5ss Fa+ AN 0 CABLES TO BE PAINTED i0 HATCn COLOR Of TO'WEN. 02,1 PLANS PREPARED FOR: PLANS PREPARED BY: NNW PIRA ow • ARCHTTECTS.ENGINEERS, P.C. SW SUITE 200 13101W000, WA NOM %ONE: 423.670 12331 425.712.0646 LICENSURE: 5773 REGISTERED ARCHITECT I j�I EIFiD, v.n STATE OF WASHINGTO DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 2010 ISSUED FOR OR CO REVIEW RLD 202 10 2 ISSLIED FOR CONSTRUCTION BAH 12 /2 ISSUED CONSTRUCTION �SEO JPIA 01/f9 ISSSUED FOR REUSED BAH 2011 STRUCTION 111/3 CONUE F FOR REV.SEB Rtfl O4/ON 20 ISSUED FOR .REVISED AD 20II CONSTRUCTION PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A-3 T.o. Exisnno } ANTE s �OF OiNERS k i SSIOV TOWER l� 25-6�i hEIM ROT. C "T.�S�NA 0 Ooglilnu Bor. PROPOSED }NVERIZN WIRELESS ANTENNAS 0' SOUTH ELEVATION' Y4E FOR NOS: I/6'- I'-0" SG.E FOR I I%12: I/16' _ -a I 4' I2' O. EXISTING ANTENNAS �1 O25'�F OTHERFa S h TnSISSION TONER 6'i hEOLIsq;NAL 801. NG SEOFSTNTNkG BOT T.O. N WIRELESS ANTENNAS O0' 0 yA� GRAD-OEY �0-OE WEST ELEVATION !SCALE FOR 24.J6: 1/6'• I -0 SGYE FOR 11%12: I/16' KEYED NOTES OEXISTING FINE HYDRANT nVE OEXISTING VOL, POLE (/IJ( J9]1J) RIZON WIRELESS P.DC.) OEXISTING BOLLARD (IYFICAL) OEOISTINC uTLa RAC1 OEXISTING ICE BRIDGE OI%BEN25 04T0C0NC EPOAUNIPMENT CABINET OF On1ERS M0.NTED ON ▪ EXISTING CHAIN LINK FENCE W/ PRVACY SLATS OEXISTING III -6 x TALL 1RANSM.SSION TOWER O EXISTING ANTENNAS OF OMENS (1YPICAL) 10 PROPOSED VERIZON WIRELESS UTILITY RACK W/ NEW 200A SERVICE METER. DISCONNECT. TELCO BOX. ILC AND GENERATOR PLUG O PROPOSED VERIZON WIRELESS 8'-0" HEN CNMN UNE FENCE W/ PRNACY SUTS PROPOSED VERIZON WIRELESS 10'-0' CORNGE • PROPOSED VERIZON WIRELESS CPS ANTENNA MOUNTED AT ICEBRIOGE POST OPROPOSED VERIZON WIRELESS OUT000R EQUIPMENT CABINETS (6 TOTAL) MOUNTED ON A S. -0- X 20'-O. CONC. PA) 1© PROPOSED VERIZON WIRELESS ANTENNAS (12 TOTAL. 4 PER SECTOR) • PROPOSED VERIZON WIRELESS ANTENNA MILE MOUNT (J TOTAL) / YG PROPOSED VERIZON WIRELESS COAX ROUTE AT TRANS/ASSIGN TOWER, 1 © PROPOSED VERIZON WIRELESS 2-J/8 X Ir.,-6' STIFF MMS 1a ))) CONNECT ro10NEft LEG (MAl i'-8' FROM OWER BRACING JgNTS; GENERAL NOTES TNO EFNLFXSRNG PN0 PROPOSED CHAIN LINK FENCE SHOWN AS DASHED LIFE FOR CLARITY. 0 8' 16' 4' 12' pU I -021 PLANS PREPARED FOR: PLANS PREPARED BY: Ni R ■ E um in A it MIN■ f I KDC ARCHETECTS.ENGINEERS, P.0 200DI SWEET SUM 200 LYNNW000, WA PHONE 425.620111.51 FAX. 4Z12120646 LICENSURE: 5773 REGISTERED AbH CT I KENNETH D. CAMP STATE OF WASHINGTONj DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRPTION BY 010 211 ISSUED ED FOR 90 O REMEW PLO 12/02 2010 SUN FOR CONSTRUCTOR BAN 12/21 2010 SSUED FOR REV15E0 CONSTRUCT ON JPM ISSuED FOR UCNON�SED GONSfR RAH AID PRO ECT: SEAQ- PONCHO S. 1C9TH & BEACON AVE S. TUKWILA, WA 98178 A-3.1 01/19 2011., ISOW FOfl RENSED `RLD 2011 CONSTRUCiiON 04/20 ISSUED FOR REVISED 2011 CONSIRUCT.ON 23120' 32.00 SEE SDETAIL 5/0-4 FOR ANCHOR DETAIL (7YP OF 6 PLACES) 9/I6, . I I/4' SLOTTE0 HOLES TO PER u..) EQUIPMENT IIENT MODCELL 4.0B 2=11 3/8" 0U1000N E001701011 CABDIE1 00.10000N & *tail 028007 MAX. APPRO. 002E1.011S PRIUARY (fi7903 KC) (900mm r510 a0 x72 9mm) BATTERY (42.70 NG) (737:7 29 673mm5.6217amm) 35 60" MODCELL CABINET MO'SNTINC SKID 20'-0" CONCRETE PAD C.INET CABINET G&N EF CABINET GFINET CAB NET i0P05� EUUP. sBINE \ 0 .Op0SE0 ORCP05E7ROPCSE[?ROPOSEC'7OPOSEE ry WE EQVIP. EQUIP. CEAr EQUIP. CABINET CABINET AB E JJ. J`. JJ ., PROPOSED OUTDOOR EOIUENTwIREUEsS CABINETS (6 TOTAL) PROPOSED p'-0" n 20'-0" CONCRETE P. (9 CABINET MOUNTING DETAIL NDT TO SCALE OEQUIPMENT LAYOUT NOT TO SCALE t12, MAB -_ Ptµ CONNECTION /-pER TO SKID P. MFR. SPECI,ATxMS Mr?) ANCKIR0 CONC. l TO BEI/2O Ni3 1/2'BOLT & M EMBED PROPOSED pOUIP.MENT CONCRETE AD ANCHOR DETAIL 411 NOT TO SCALE USED (DNOT NOT 70 SCALE VERUCN WIRELESS OUTDOOR UEOMPMENT CABINETS (6 TOTAL) H...H. r rr m I II. L 1-0O OOE1= 10 .ot O.D: RARF -PROPOSED B•- x 20 _O' e CO RETE Pao EQUIPMENT ELEVATION (DI NOT TO SCALE PROPOSED VERIZON 'WIRELESS OUTDOOR EQUIPMENT REPOSED vERI20N W OUTDOOR (6 TOT .) GBINF.TS (6 TOTAJ is t .t maw CABINETS (6 TOTAL) ' ❑ • • • I .l II PROPOSED B•- x 20 -0 CONCRETE PAD ■ PI AN VIFB CHAMFER FINAL SLOPE D D P, f l f f l f to m 0 0 ;RAVE CONCRETE lo COMPACTED CRUSHEDCR ASis OTIO RENAL) THICKNESS ,[�,OAOFAs_A C xREMOVE G RTIO S REO'D) Q OF S.J9 MNDES STONEE. REOUIREO I. FOR CONCRETE NOTES SEE DETA� L 3/a-5.FOR CML NOTES SEE 2. GRAVEL SW:L B_ Ral OR CRUE yED STONE 1viH 00 PERCENT PASSING D R6O TO II UH ED NATURAL` LACE CROSSED DETAL 4/A-5 f t ` t ( ! 7} r'r '( 1 L(L— O O 0 O 1 PRADF `\\ CONCRETE POD `PROPROPOSES e'- x 20'-0-e6 n._ gm CONCRETEPAD DETAIL EQUIPMENT ELEVATION EQUIPMENT ELEVATION O NOT iC SCAT MIT NOT i0 SCALE O NOT 10 0444.1 c.GIZON VARELE55 PROPOSED OUTO DOOR (6 TOTAL) GESN -T5 (fi TIu PROPOSED EOulpucyr CABINET RUBBER BOOT (LUCENT PROVIDED) CABLES (LUCENT R ENDED) •O 2" LIQUID -TIGHT STEEL FLEX BLE CONDUIT z" LOUID-TIGHT CONNECTOR (ASSEMBLY) HUB/CO2PUNG(PAR1 CF CABINET) 2' IOUID-TIGHT CONNECTOR (ASSEMBLY) STEELFLEXIBLEii Ili [] I� m m 1 PROPOSED B'-0' x 20'-0' CONCRETE PAD MI '1.PROPOSED 0 0 X 20•-0 CONCRETE PAD .-- / e ONOT USED 11 P!T ENTRY POINTS DETAILS 2 EQUIPMENT ELEVATION O NOT TC SCALE n0i i0 SCUE NOT TO SCALEA-a epu -al PLANS PREPARED FOR: PLANS PREPARED BY: KDC ARCHITECTS.ENGINEERS, P.C. 020 200114 STREETSW SUITE 200 10711000..190036 NONE: 4266..6151 2.0.6 LICENSURE: 5773 REGISTE ED R{IT T KENNETH D. CAMP STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLO CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 SUED FOR 90% CD RENEW RLO 12/02 2010 SSUED FOR CONSTRUCTION Bµ 12/21 2010 ISSUED UNSF FOR REVISED CONSTRUCTION 01 '1= ISSUED NSTRUCROPEN5E0 BAH 11 i3 1 CSONS1FUCT10rSE0 RL� 04/20 ISSUED FOR REVISED A0 2011 CONSTRUCTION PROJECT: SEAQ— PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A-4 . NOTFA• 1. IN SERT RT SCISSOR BRACKETS BETWEEN THE UPPER ANTENNA MOUNTING BRACKET AND THE UPPER POLE ADAPTER BRACKET. SECURE USING 1/2 INCH HARDWARE PROVIDED. 2. TO SET THE DEGREE OF DOWNTILT. AUG.v THE DESIRED HOLES ON THE SCISSOR BRACKETS AND SECURE BEING F c16 NEC ORS WILLHARDWARE PROVIDED. THE NUMBER VARYBA BASED ON ANTENNA TYPE. ON TONAL 00WINTILT BRACKET IL ALMONTMICNT RO (OP) PART #81001 D APPROVED EQUAL PANEL ANTENNA (CCP) PARTS: ITEM OTI DESCRIPTION ADAPTER, POLE. LOWER BRACKET,DOWN.WT, POLE , BRACKET OWNTILT, ANTENNA 1/2 X 1 HEX HEAL BOLT E I L ] I/2. SPLIT WASHER 1/2 NUT 1/2 SPLIT WASHER 5/16 X 1 HEX HUD BOLT 5/16 SPILT WASHER I/O' THREADED ROD GENERALNOTES. 1. THE CONTRACTOR SHALL COMPLY wI 4 ALL LOCAL AND NATIONAL CODES. REGUIATIONS AND SA REGULATIONS, ALL PUBLIC AN MUNICIPAL AUTHORITIES. AND ANY UTILITY COMPANIES' REGULATIONS AND DIRECTIVES. 2. WORK. E ACT DIMENSIONS ANGS AND NDFl LOCAL, SONS IE Y CHANCE GENERAL IN THE FIELD. THEE SCONE OF AC OR IS 0 VERIFY THE DIMENSIONSAV.LOCATIONSTANDFI REPORT MT AND AL DIRAWINGS OES TO REPESENSTOI ANO MINORHRRORS AND OMISSIONS IN THE DTHE RAWINGS ROJECTUANOEIMPRAOVEEMENTS IN NOT THE CO E INTENT OFOTHESE COMPLETING DOCUMENTS. IMPROVEMENTS SIN ACCORDANCEH H . CONTRACTOR IS RESPONSIBLE FOR FIELD ME.NURE ETTC CONFIRM LENGTHS OF CABLE TRAYS AND ELECTRICAL ONES A. ANTETIN G. 4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PR0PBSE0 ANTENNA. COAX W ADO ,Nei EQUIPMENT G IS TO BE DONE BY OTHERS. CONCRETE WORK SHALL BE IN AccoROANCE wlTn A.C.I. 301. A.C.I. Sln AND THE ETI 2. UNLESS NOT DOTHCAST-TN-PLACE CAST-TNCP'LAGE CONCRETE SHALL BE NORMAL WEIGHT. RAINED CONCRETE WITH A Eit.NUM COMPRESSIvE STRENGTH POUNDS PER -I PORTANDCEME 25� L RE USEDWITHA MAXW UTU ZAGGREGATE s E J/4 Aro tx tIX EN PMEN1. NJ CONCRETE WAIL HAVE A u2x0IUM WATER/CEMENT (w/C) RATIO OF 0.4B. J. ILICONCRETE FUMORK SHALL TUNE 4 STIFF BROOM FINISH AND HAVE A SLOPE OF 1/5" PER FOOT OTED 4. REINFORCING BE NeWT BILLETSTEEL CONFORMING TO AS.T.M. A615. GRADE 60. DEFORMED. . DETAIL FABRICATE MD ERECT RBNFORCEMENT BASS, INCLUDING BAR Su A.1966)VCF WITH 'DETAILING OF CONCRETE REINFORCEMENT. (A.CS. ISPACERS. - .IREV. 195E). E. UNLESS 10i SHALL BE CLASS B CONFORMING TO ACI 31595 - 7. A CHAMFEROF1" SHALLBEALL ALL EXPOSED EDGES OF CONCRETE IN ACCORDANCE H .I. t SECTION 24..4 u W. 55 OIN RNOTED. B. CONCRETE *CPR SHALL BECOORGIN.ITED W. THE MECHANICAL. EBUIPMENT, AND ELECTRICAL WORK TO ASSURE Two ALL ASTECTED PIPES, CONDUITS INSERTS, IN PUCE MID 9. F1 HFORE PLACING CONCRETE. CE E CONCRETE COVER RE ORCµG BARS SHIN, CONFORM TO THE FOLLOW. UNLESS wDIUTED DTHFJMISE ON RE . CONCRETE EXPOSED TO WEN.. OR INN C.TACT WITH -CONCRETE CAST AGAINST EMTH- INCHES 10.000RONATE LOCATION OF STEEL ANCHOR BOLTS WITH STEEL FABRICATOR PRIOR TO INSTALUITON IN FIELD. 11.CONTRACTOR L PROVIDE SLEEVES FOR ALL w0LI/SLOB PENETRATIONS (PIPING, CONDOT,ETC. POWER. TELCO ANC COAX TO ENTER SITE UNDER EQUIPMENT SUR SEE STUB -UP PUN [0 ANTENNA MOUNTING DETAIL GENERAL NOTES NOT TO SCALE UNNER. PIPE ADAPTER .1 NAT NO 01534 EXISTING EE MOLE POST OR SILO. POSIT FI NATION (WAX SUKCUIL 0TE (SEENOTE X ZED I NOTEm) 51.0.7.1 SURFACE AREA oF A HELASPHFRE AROUND THE CPS ANT.. 2. AU. CPS 11,..1LOCATTONG LLTST OF ABLE TO SIGNALS FR. A Gnu.. OF FOUR (4) SMEWTESECC00 w)1H HANDHELD CPS BEFORE F.NAL LOCASON OF MIS ANIEN., J. THE WEIGHT D< THE AMEN. MOUNT cS N6 IBS.iCE MD Co61022EO TO GRGUND Mxe. He010101Y . 0000 TO RH n 004 (INSTAL FENCING PER ASTM F-567, SW. GATES PER ASTM F- 900) 1. GAZE POST, CORNER, ENO OF LL POST 4" NONINA: (4.5" C.D.) SCHFCUIE 40 PIv LBS/LIB FOOT FOR GATE WIDTHS UP TKRU 6 FEET OR 12 FEET FORDOUBLE SWING GATE PER ASTM-FIUB_. 2. LINE POST: 2-1/2" (2.875" 0.0.) SCHEDULE 40 PPE. 3.65 LBS/LW FOOT PER ASTM-F10]. AGATE FRAME: I I/O " (1.B75" OD) PIPE. 2.72 LBS/UN FOOT PER STM-F1083. 4. TOP RAIL 0 BRACE RAIL 1 I/O " (1.875' OD) PIPE. 2.72 LBS/UN FOOT PER ASTM-FIND. 5. FABRIC. 12 GA CORE WRE SIZE 2" MESH, CONFORMING TO ASTM-A]92. 6. TIE WIRE: MI STEEL,AiRAILS WRAP OF FABRIC TIE ANTI AT TENSION WRE B HOC RINGS Sv CE0MAX 24- INTERVALS. 7. TENSION WIRE, 7 GA. GALVANIZED STEEL S. BARBED WIRE: DOUB_E STRAND 12-I/2" OW TWISTED RE TO MATCH WITH FABRIC 14 C, 4 PT. BARBS SPACED ON APPROXIMATELY 5" CENTERS. 9. GATE U CH: - 0/e ' O.D. PS 08060 RDD w/ NUSHROOu 11K LATCH AND LOCK. KEYED ALnE FOP AL 1E5 W A GrvEN DATA ,CAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENT SHALL BE , COMPLIED IF ECUIREO. I. HEIGHT - 6' VERTICAL 0 1' BARBED NITRE VERTICAL DIMENSION. 12. INSTALL VINYL SLATS, CONCRETE NOTES GPS ANTENNA DETAIL FENCE NOTES OT TO SCALE DBL. WIDE ACCESS GATE DETAIL O SCALE WNOTI5 ON DEINL 6. TRICAL SECTION 1WSION TOP OF FABRIC CILI Y SIDE GROUND ANOv5L0PE CORNER, ENO OR PULL NOSE (O. NnM1 SCH . 0 PIPE) U.'.0. STRETCHER BAR DIAGONAL ROO TURNBUCKLE (TTP.) DRAGE RAIL LATE SITE 'HORN SHALL BE AS INDICATED ON THE DRAWINGS AND STIPULATED IN 1-4E SPECIFICATION PROJECT SUMMARY. 2.RUBBSH. STUMPS. DEBRIS. STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THEN D DISPOSED ] IHESILL GRADED 0 R CAUSE SURFACE WATER TO OW AWAY FROM THE PCS EQUIPMENT, TONER AREAS. AND ADJACENT BUILDINGS, 4.N0 FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN NATERIKS. SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. S.TPE SUODRAOE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRAPE PRIOR TO THE CRUSHED STONE APPLICATION. GP RADF AND RASE PRARATION- FOR ISLAB-ON-GRADE CONSTRUCTION IT WILL BE NECESSARY TO OVEREXCAVATE THE SITE BY 2'-0" AND IMPORT AN APPROVED GRANULAR FILL. THE FILL SHALL EE COMPACTED TO T LEAST 95R OF THE MAXIMUM DRY UNIT WECHT WITH A MOISTURE CONTENT MTHIN 25 OF 1FE OPTIMUM MOISTURE CONTENT AS DETERMINED BY THE MODIFIED PROCTOR TEST USDA D-1557).COMPACTION REQUIREMENTS APPLY TO BACKFILL FOR UPUTY TRENCHES NO FOUNDATION EXCAVATIONS WITHIN STRUCTURES, DRIVEWAYS, OR PARKING LOT AREAS. 2.CCMPACTION SHALL BE ACCOMPLISHED BY PLACING THE FILL IN SUCCESSIVE, H0R120N`AL, APPROXIMATELY SIX- TO EIGHT -INCH LOOSE LIFTS AHD MECHANICALLY COMPACTING EACH LIFT TO AT LEAST THE SPECIFIED MINIM. DRY DENSITY. ].ANY ORGAN'C MATERIAL. DELETERIOUS MAI'A ER, OP OISTJRBED SOIL SHALL BE REMOVED FROM FIAIWORK AREAS. 4.111,,E,GIOU;,13 CIRFCTIONSUR DUNDING EXTERIOR STRUCTURES SHALL BE SLOPED TO DRAIN CIVIL NOTES Or TO SCALE REMLC,S LECGTAPPO ENOT BY 001 WIDE ICE BR OGE Et B II LENGTH TOSUIT (SEE NOTES) TRAPEZE KO 2) TRAPEZE KITS ARE INCLUDED WITH E BRIDGE. ORDER ADDITION, TRAPEZE KITS AS REOUIED. TO MAINTAIN UM CABLE SPAN OF ] 0' (TYYP) ANTENNA CABLES ARRANGEMT BY CONTRACTOR �CON<RRE PER u IY// L1 • STALL DR ANTENNA C4101O nT oonoM OWER/MONOPOLE. BENDING RADIUS PER NANUFACTuftER'=_ STANDARDS N01ES: I. WHEN USING COMPONENTS AS SHOWN IN STANDARD DETAILS, MAXIMUM ALLOWABLE SPA' BETWEEN SUPPORTS ON A CONTINUOUS SINGLEINN SECTION OF BRIDGE C..NNEL SHALL BE 9 FEET FOR 10 FEET BRIDGE CHANNEL 2. WHEN USWG COMPONENTS FOR SPLICING BRIDGE CHANNEL SECTIONS, THE SPLICE SHOULD BE PROVIDED AT THE SUPPORT. IF POSSIBLE. OR AT A MAXIMU.v, OF 2 FEET FROM RE SUPPORT. ], WHEN USING COMPONENTS. SUPPORT SHOULD OBE PROVIDED AS CLOSE AS POSSIBLE L CH A MAX MUM CANTILEVER DISTANCE OF 2 FEET FROM THE SUPPORT TO THE FREE END OF THE ICE BRIDGE. CUT BRIDGE CHANNEL SECTIONS SHALL HAVE FA TREATED OR D WITH A WAIT RE. FINISH, ITORESTORE THESE EDGES TO THE OR.O., CHANNEL, 5. ICE BRIDGES MAY BE CONSTRUCTED W H COMPONENTS FROM OTHER MANUFACTURERS. PROVIDED THEMANUFACTURER'S INSTALLATION GI/GEL/NES ARE FOLLOWED. 6. DEVIATIONS FROM STANDARDS FOR COMPONENT INSTALLATIONS ARE PERMITTED WITH THE RESPECTIVE MANUFACTUAPPROVAL. 7. DEv1AIANS FROM ICE BRIDGE FOUNDATIONS REQUIRE ENGINEERING APPROVAL O5CHAIN LINK FENCE DETAIL NOT TO SCALE CHAIN LINK FENCE CORNER DEATAIL OT i0 SCALE 0 ICEBRIDGE DETAIL NOT IC SCALE PLANS PREPARED FOR: PLANS PREPARED KDC ARO4RECIS.ENGINEERS, P.C. 4720 NOM SWEET. 11111E 200 MIME: i2sm01M FAX, 42371506. LICENSURE 5773 REGISTERED ARCHITE DATE: 04/20/201 ORAWN BY: RLD CHECKED BY: kC REVISIONS DATE DESCRIPTION BY ISSUED FOR 905 CD RENEW RLD 12/102 SUE(' FOR CSONSTRUCIDON BAH 2010 ISSUED R REVISED CONSTRUCTION JPM Is5N5 F FDRuCipry ""° BAH ISSUED CONSTRUCTIONFOR DASED R,D ISSUE° FOR ENSEO CONSTRUCTIONq10 PRO ECT: SEAQ- PONCHO S. 109(H & BEACON AVE 5. TUKWILA, WA 98178 A-5 TIE WRAP CAOLCS TO FORM CLUSTER ATTACH CLUSTER TO INSIDE OF TOWER LEG WITH TIE WRAP 0 TIE WRAP CABLES TO FORM CLUSTER NICROFLECT 82250 AL 11'-0" 0.C. ERTICKY UP INSIDE OF TOWER LEG JOINT (NODE) OF LATTICE TOWER, TYP. aiiACH CLULESTGERWTOITH Irv51DE Of TOWER WRAP o (C-a' C.C. CLAMP BACK H 1 2b.12" BOL n E" TnREO 150P OF 2) 1 /2'e A 53 0 IX NUT WITH WASHER(TYP OF JOINT (N00E) OF LATTICE TOWER. TYP. .NICRCFIECT 82250 AT I -0" D.C. VERTICA_Y uP INSIDE CE TOWER LEG OCOAX AT TOWER LEG DETAIL NOT LO SCALE utcvERSAL axiEnflNA mousT AT 0; REFER TO DETAIL 2/A-6 SITE PRO I SECTOR FRAME SAFE ARM KI -3/8' x 6" (P/N? Six-u . HIT TTACHES W/ SITE PRO I uN VEPSAL STIFF ARM ATTACHMENT (P/N: SAM-U) ANTENNA MJL:NTING PIPE D58550. SHOWN FOR VALA1GNT/SITEPRo1 PART /EUSF10-2u AND IS SUBJECT TO CHANGE. QCIXARACTOR TO�EFY PARTS PRIOR TO c�STRULTTON. PARTS LIST HARDWARE LIST PARTS LIST B2250 NARK DfscRani N ON STu OTT DESOOPTIO.N 5 -G LTS 121/5 IDA576 1 5>x — _ — CLAWIBMX HAEF PUSC x won AsSY. 1 / 6' 2 BOLT w FApS %3e LOCK wRAWE8 Nui OTY 2 I Z1220 / IT688 ZlfiBl T62a 27665 ANGLE avGS ANGLE PLATE PE WEUX NT PLATE WEIDUENT I 6 1 WS 6 Wl 12 NTS 16 5/82 x 1 f/A CS DOLT, mg 6 L.W. 5/84 x I GS BOLT, . k LE( 5/55 x 6 I/2 GS BO T. Nui W 1.p. /Bx LOG( wASNFR 1/8f LOCH WASHER 5/BF A563 CR. A Ha NUT TOTAL wOOHT MOB . 9/ L 6 1 1 .' goAx CONNECTOR = 1•Nr7 `Ern ® (12) 3/A"0 SNAP -Iry (10) 2/161 oR aurrERFLT KIT Y CDDANGLE HOLES FBR ',..= 5 HOLES FOR JSHION HnxcERs D 2 1 ,m.x A56e CR. A Ha NUT i%B0,um H READED ROD R� 5/06 x 1X THREADED ROD 21605MEI USE TH5 LOCATION Fos tor. Gov REICHT: 150A 0 1/2 X ♦ 1/2 TO 6 X 6 PPE IEG5 cR LEGS FROM 6 5/8 00 To 6 5/8 OD aor I/EM MY ir LoCAlioN Fox ,2V2To "'\I01`I> 1ZSEINS W 2WTOLIE/D _M, �7� t5.5' ®' I 5Mld `ARTX%'L TO LEG SLOPC NANOE ® . 0 FACES III III ICA TOWER LEG /2 C.D. X ® PLAN VIEW 0 n686 27685 1 CP EMI ECCROFLECT 82250 O VATH TO BE uOuuTED " D T FROM PN Ex151ING TOWER JOlxi• _ WIGSUPPORT � � T'` EMIPIP[ i -SNB X '2" I NOu nry PIPE. vKNONOt MICR tLCCi PIPE MOUNT PART /CMOS L P NIII HANGER (. NP .SEM13 PUTS ASSEMBLY WITH (12) FOR - 0 ��� ' 3/A'0 HOLES SNAP IN HANGERS SECTION A -A MT ® \ -- 11,18� '' .— Mil MouNTE. PIPE CO" LOCK 2) 'x15TING TOWER ACE 0055 /D 21/0 5 XISTING TOWER LEG ATTACH CO. TO TOWER LEG WITH TIE RAP AT N X. -0" O.C. 1 FIND CO ll( TIE. WRAP al-0' O.C. ��•� (6) CO. ROUTE y` 1�•uJ/^•r.X� 0 �r= 1i .7— 8 ES Pu[ ALMONT MICROIFLECT TO OUNT I _;id ,GI PPIPE ARE /025P3 `_\ III --L. TYP. 6 RACES ELEVATION _': _ : 210e9 1 PPORT TO MOUNTED 1'-6" u ExOTTNG TOWER �W CRoss-ARM 6O I II* PLAN VIEW SECTION B-B ANTENNA MOUNT DETAIL O2 NOT TO SCALE USED NOT USEDdi NOT USED ® NOT to SCA, Ilar NDT TO SCALE ONOT NOT TO SCALE ?(,11 6S( PLANS PREPARED FOR: cu PLANS PREPARED BY: KDC ARCNRECTS.ENGINEERS, P.C. 020208111 ST061 SW SUITE 200 M2W000, WA9 SS OTE: A25.6R 1 FAX 425J12.8646 LICENSURE: 5773 REGISTERED ARC TECT I PD. CALF STATE OF WASHINGT DATE: 04/20/2011 BRAWN BY. RL D CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 0 2010 COX GCDFRENEw RLD 2/02 CONSEflu[tKK. BAH 12/21 ISSUED fIXV RMSEO CONSrflUCLXM' JPM O1/10 iSSuED OR REVISED ONSTRUCTKK: 01/0 CSONSERUCTKINO FOR RFASEO 80.14 RL� OAO/20 ISSUED FOR Pf 2 I CONSTRUCTION n10 PRO ECT: SEAQ- PONCHO S. 109TH & BEACCN AVE S. IUKWILA, WA 981/8 A-6 A NC / ISO VOLT. I PHASE. l 200E PANEL TYPE. SQUARE 0 NOTE: NE. 36 MEOW. CCSCRPOCN I(vA) BRu¢a OCTH. CCI [A�fx/ P I(VA). DESCRWRW RECTO. WOOER RECm1ER PFnVYA w3IUYR RECOMA yyyy son0 2000 SOX 200C 20.0 O /2 JO /2 30 / /2 10 / /2/ 00 / 2 / PAWL 1 0 /2 to /2 / / / 2 / I IC / I SC / I 21r0 s A n, u£STCR UMT CM RECEPTACLE SvACE SPACE SPA. 5002E .OWO TYPE L pow. LOAD c - ..CR LOAD FACTOR KvA f.ran LOAD 6/060. !0!A M 0 IWx TKVA MTV � RVA ANR .wn Hos A-e w M.N. MOST RE ON Kw FA.lOR O (l !WO) 20 CD (J /J/D & 1/6G) 2' C C PJa0/J/k GPNEL Q I p4Cu C'A • J/. c. Al CONDUCTORS REM I. BE COPPER COPPER 600,E .1E0 WITH REHN ANSMIATION MOLINE TO EXISTING UTILITY POIEWITH TRANSFORMER NEW UNUTY METER wt MNN BREWER M untEO TOT NFw UILItt RACK ELECTRICAL NOTES INSTArr 0. SECONDARY POWER AJD CO METER SHAEL BE LSHIN IN LAWS, NCf M NA IONS FO CODEON iATE OFMWA HINGTOL LAWS, RVLEG AND F WITH S ONS FOR IN WIRES k • P. ST5 AL GUEST ISSUE, AND wM LOCAL PUADOnS iPERNAS iLMETB 23I, B ROD, NSA. s 1- 0I, I.c.EA. PB1-620, l C L P D. 2. PROVIDE EBACK MEIER E PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE CE 2 J. UM1 ERGROJNC CONDUIT SHALL BE RI E CONDUIT: SCHEDULE • tYPE FORMING TO 1 WESTERN CHLORIDE OR CARLON MANUFACTURER. MUN IN= SHALL BEGS. SOLVENT. WESTERN TYPE CD L RENDS TSH LL BE -MOE SWEEP. A 2a' MENAMUNI Rap R ROADS SHALL BE NS. (OR PVC ▪ E ENCASED 'n a FIB' RED CONCRETE =Cr..)NU a. QUIT USN INDOORS SHALL RIGID ER TE AND ROD GAVANINED STEEL FOR OUTDOORS. COAL LMCS SHALL B: M IO TYPE FOR E.M.T. SET E NOT PERMITTED. FOR ALL STUBS -UPS. USE RIGID GALVANIZED STEEL CON., 5. 'SIRE AO CABLE SHALL BE OF THE TYPE AND 52E AS RHO RED BY NEC. THERE P L BE NOS I OWED PROVIDE HOPE PULU G N HAND HOLES AS NEEDED. it TOF SHALL PROVIDE TEST O ME ROUNDNGESTMSTEM BT CERTMAFl�EED E InOEPENDEniFiESi FESulis i E PR ER FOR NMRESISTANCE TO GROUND SHALL NOT ALL ABOVE GRADEE W RIORGRO LLL BE 0008.£DONUS LUG. COMPRESS ON TYPE. ALL EELCw GRADE AND EXPOSED EXTERIOR GROUNDING RENTS s'uLL BE CADWELO CONNECTIONS CAE ASHALL BE U TACEN E0 RA.E. CORROSION. LOCATORS AD MA ENIA TYPES TO AVOID POSSIBLE GALVANIC ORR SIOv EXPOSED GROUNDING CONNECTIONS 10 BE COATED WITH ANTI -CORROSIVE AGEN SUCH AS vN0-0%Y', OR 'PENN... VE T ODUC WITH PROJECT WA'AGE, ALL BC `TS, WA▪ SHERS AND NUTS USED ON GROUNDING CONNECTIONS SHAY_ a SEAMLESSEEL. 7. ALL E EXTERIOR GROUND PARS aL BE COATED WITH ANTI-CORROS.AE AGENT SUCH A EQUAL. -UNCTIONS. ALL BOXES DESIGN. ING ALL CIRCUIT NUMBERSCONTAINED IN EACH BOX. HFOY TAPE.OR 9. CONT.RA:DIOR TO ENSURE TLC PROVIDED WITH (2) INTERNAL M5. O. CONTRACTOR SHALL COORDINATE WITH TEE SURVEY TO LOCATE EXISTING UNDERGROUND ERGROOOUND UTILITIES. WHEREVER OTENNT._ CONFLICTS/ N n'CES E%ST. • EXCAVATERE TO AVOID n Au TO LOCATE UNDERGROUND PTPINCN uE C ROW. 11. VERIFY THAT A.I.C. OF ME UTILITY DOES NOT EXCEED THE AN. RATING OF ME C. FRONDE FUSIBLE SERJ.CE ENTRANCE SWITCH AND CONFIRM LOWERING O- A.0 TO ACCEPTABLE LEvELS. ftK / MATERMLS Sn0'WN ME BAEO UPC JUINARYNFORMABON PRCTAOED B�iHE UHptt COMF/NIfS ANO ANE FOq 80 PURPOSES ONLY. 13. CO FOR FINAL AND EXACT WORK / Wi_RKS Eft Ou1REEMENS . ...7OTO Tu 0[tt COMPANY ENGINEERING PUNS AND SPECIF.AIIONS ONLY. N CR SHALL NRNSH AND INSTALL ALL ROPES. CABLES. PULL BOXES. CONCRETE ENCASEMENT OE CONDLR (IF REQUIRED),R• i TPA RMLRE PAD - TRENCHING. BAC`E.. PA COMPANY f S AND INCLUCE ALL REOOREMENTS�NNSCOPE RN. IA. ELECIR. L DETAILS AND PAWS SHALL BE RENEWED BY SEATT E OTT LIGHT ELECTRICAL ENGINEERING. 20CASP IENCLOSURE I/pa1 GI 3(0 FRONDED N9i0CPA EILLCA' 0 200A NCB Ax L ~IINTERLOCK `\ `—PANEL00ARD WITH INTEGRATED MANUAL TRANSFER SWITCH OV'.OED BY VERIZON WIRELESS ELECTRICAL LEGEND — — — — VEWAr0UN0 —�- FUSED DISCONNECT TRANSFORMER Q FEEDER KEY GROUND PANELBOARD 0 METER ELECTRICAL LOU PHEW L----I ENCLOSURE — GROUND CONDLCIOR PANELBOARD ZS FUSED DISCONNECT EpLOCI DISCONNECT OGROUND ROD T2 EXOTHERMIC 'WELD • COMPRESSION CONNECTION .PE CITEST WELL r--1 AUTOMAT. IL�J I TRANSFER SWITCH © GTWCRATORD-B EN ABBREVIATIONS AWG AMERICAN WIRE GAUGE BCW BARE COPPER WIRE DWG 0RAVRNG EMT ELECTRICAL METALLIC ENSUING 0 CEI000ATOR ICR ERIORGRCUNDA R.NG (HALO) AMC INTERMEDIATE METALLIC CONDUIT NGB MASTER GROUND BAR PCS PERSONAL COMMUNICATION SYSTEM RGS ROD GALVANRED STEEL RWY RACEWAY TYP ttPICAL WADE GRC EJW lYP.CALLS UNDERGROUND SERVCE 12E/2a0V, 2 0, y--]0a i-0' LRNG ANOE10 RI TO GROUND HNG ONE -LINE DIAGRAM PLANS PREPARED FOR: PLANS PREPARED BY: KDC ARCHREC1S.ENGINEERS, P.C. 200211 STREET SW WM200 L22121Y0001. WA NOM NM. 425.620.6651 fAK 415211.0616 UCENSURE: 5773 REGISTERED I TE T i, KENNETH D. CAM I STATE OF WASHINGTONI DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION II/I2 ISSJED FOR 2010 902 CD RENEW 102 ASH!. FOR 210CCION 2120/210 ISSCONSiJEDgFOR REVISED UCHON 11ISSUED F. REVISED CONSTRUCTOR 2 °i IJ' ISSUEM FOR R SN 0 D UCT.N 1/20 ISSUE° FCR REVISED 2011 CONSTRUCTION PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 E-1 BY 920 BAH AIO 1.. .-.." ISM ELECTRICAL SITE PLAN ISCNE FOR 24.36: 1'. 20-0' sc2E FOR 11107. 1' 40-0' II 20' 40' CDI 10' 30' NORTH KEYED NOTES SNAG DIR+ ACCESS EXS9NG O.H. POWERLINES (MICR) <>EXISTING UTILITY POLE (i1339373) (VER2ON WIRELESS P0.0.) 40EXISTING B0LL.90 (TYPICAL) O3 EXISTING TIRE HYDRANT OEXISTING SINGLE FAMILY RESIDENT OE%.STING BRUSH UNE OFASTING GRASS AREA <>PROPOSED TERROR WIRELESS U.G. POWER/TELCO ROUTE (APPROX. 30'2) 10 PROPOSED VERIZON WIRELESS µTILITY RACK W/ NEW 2002 SERVICE YETER® DISCONNECT, ELCO BOX, ELAND GENERATOR PLUG TAW GENERAL NOTES PAS Ei NCR SITE SURVEY. ALL PROPERTY BOUNOARIES, ORIENTATION OF TRUE NORTH AND STREET HALF -WIDTHS HAVE BEEN OBTAINED FROM A MA PARCEL MAP AND ARE APPROMMAIE. O NOT DU ONI CALL BEFORE YOU DIG! BURIED BTU' ES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE -CALL U Utt LI-E SE.RVCE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTIO.I-E00-424-SSSS 702401TFI C0 N11R POHER TO ORIGINATE THOM IRE EXISTING uFIUIV' POLE (/1339373), THEN ROUTE U.C. TO THE PROPOSED METER/OISCONNCET. LOCATED ON THE VER130N 'MRELESS PROPOSED O TIUIY RAC0. (APPROX. 30'-00-S) TELCO TO ORIGINATE FROM THE EXISTING LLE (11339373). THEN ROUTE C. TO TO RAGA, (APPROX 30'00-.+) PROPOSED rBOX. LOC..ON'HEPROPOSED HERON WIRELESS uNMC FNFRA9NOTTS' REFER - 2/A-5 FOR GENERAL NOTES. ELEC1TRICALI DETAILS AND PLANS SPALL EE REVIEWED BY SEATTLE CITY UGHT ELECTRCAL ENGINEERING. PLANS PREPARED FOR PLANS PREPARED BY: NM NM if R iE IN ■ ■.. I t ■$iII KDC ARCHITECTS.ENGINEERS, P.C. 472 SWEET SURE 100 36 MINE: 423.670.6651 FAl 4.15.712.0046 LICENSURE 5773 REGISTERED I ARCHI • �T KENNETH D. CAMP STATE OF WASHINGTO DATE: 04/20/20 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 17 Is 2010 90%D ISSUED FOR RLD 12/02 ISSUED FOR 2010 CONSTRUCTION I2/z zDla ga&j..cnorsm 1/10 0C54O+SERONE+I.5E0 $ TRUC BAH 01/3 2011 ISSUED FOR REVISED CONSTRUCTION RLD 20 10 ISSUED FOR REVISED CONSTRUCTION PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE 5. TUKWILA, WA 98178 E-2 GROUNDING tp EQUIPMENT OELECTRICAL GROUNDING PLANS 0 E ) SCALE FOR 24T16: 1/6- 1'-0' SCALE FOR 1141I: 1/0" GENERAL GROUNDING NOTES KEYED NOTES ALL ELECTRICAL W L BE PERFOaMEO I.N ACCORDANCE. WISH THE DESIGN ArvU CONSTRUCTION SPECIFI[ATIONS AND ALL APPLICABLE LOCAL CODES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS 50 THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. D. THE CONSRLLA1I 15 REi PoNSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNOLNGNOUND CONDUIT SAL CONDUIT. AS 0 PREVENT ANY LOSS OF CONTINUITY IN E GROUNDING SYSTEM OR DAMAGE TO THE DUI. 4. ALL GROUND CONNECTIONS BELOW GRADE SHALL DC EXOTHERMIC (CADWELD). 5. ALL. GROUND CONNECTIONS ABOVE GRADE (INTERIOR h EXTERIOR) SHALL BE FORMED USING TWO (2) HIGH PRESS CRIMPS. 6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TCP k HAVE A VERTICAL SEPARATION CF 6' FOR EVERY ADDITIONAL CONNECTION. ). ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RF5ISTANT MATERIAL. 8. ALL EXTERIOR GROUND CONDUCTORS SHALL BE M2 AWG TIN PLATED COPPER UNLESS OTHERWISE INDICATED. 9. GROUND RODS SHALL BE S1A:NLESS STEEL 07 COPPER CLAD STEEL 5/8'4 10-F1..ONG. AN0 SHALL BE DRAEN VERTICALLY wITH iMC1F TOPS iB' OELOW FINAL GRAOC OR G" BELOw FROST LMf FOR MAXIMUM DEPTH. O. CONNECTIONS TO THE. GROI,NO Bu5 SHALL NOT SS U UBLEED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. 1I SC EOF BE ADEQUATELY INvi110 PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 65' FROSTBEND. GROUND RING SHALL BE LOCATED A MINIMUM OF 247 BELOW GRADE OR 6' MINIM,1 BELOW THE D. INSTALL C. D GROUND ROD MINIMUM OF 1'-0ERMA EQUIPMENT CONCRETE PAD, SPREAD FOOLING. OR JFENCE. AN 14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLO GALVANIZED 15. OBSERVE N.L.C. AND LOCAL JTILNY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNCING 16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS CH AT GROUNDING POINTS PROVIDED (2 MINIMUM) 12. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OFMS. 18. ELECTRICAL DETAILS AND PLANS SHALL BE REVIEWED BY SEATTLE CITY UGHT ELECTRIGL ENGINEERING. 19. CONTRACTOR TO VERIFY CURRENT VENISON WIRELESS GROUNDING STANDARDS PRIOR TO CONSTRUCTION. O/2 AWG BICW GROUND RING, IY OGROUND R00 SPACING ID 10'-0" C.C. MIN. 15'-0" 0.C. MA OEXISTING TRANSMISSION TOWER GROUND RING O CONNECT AGB TO MOB WITH (2) 02 VOW © EXISTING MGB 0 BASE OF TRANSMISSION TOWER O CONNECT ICE BRIDGE 70 GROUND R,NG. (TYP ALL ICEBRIDGE POS I) OMASTER GROUND BUS BAR PROVIDED BY EQUIPMENT MANUFACTURER O9 CONNECT PROPOSED SERVICE UTILITY RACK AS PER N.E.C. CODE O CONNECTMASTER GROUND BUS BAR PROVIDED BY EQUIPMENT MANUFACTURER TO PRPOSED GROUND RING WITH (2) /2 BICW OCONNECT FENCE POSTS TO PROPOSED GROUND RING WITH (2) N2 HTCW OCONNECT PROPOSED ANTENNA WITH B2 STOW TO A. (TYPICAL AT EACH ANTENNA) ONEW AGO 0 ANTENNAS OCONNECT GPS ANTENNA TO GROUND RING OCONNECT FROM EXISTING M. TO TRANSMISSION TOWER GROUND RING (2 PLACES MIN.) • CONNECT GATE SWING TO PROPOSED GROUND RING WITH (2) X2 BTCW (TYP,CAL AT EACH POST) OGROUND TEST WELL (MIN. OF 2 PLACES) 0 0 NIP TYPICAL GROUNDING El ANTENNAS ?LA l -021 PLANS PREPARED FOR: PLANS PREPARED BY: MEM NNW MU Tr IMF MI IS R I MINI II ■ f 11111.1 A 1 I R■III 1 KDC ARCHITECTS.ENGINEERS, P.C. 4720205111 STREET SW SUITE 200 PHONE: °SAMBA. fAX 425.712.0046 LICENSURE: 5773 ERED fECT KENNETH D. CAM I STATE OF WASHINGTONI DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: E„C REVISIONS DATE DESCRIPTION BY 11 /1 7 2010 ISSUED R BOX C FOR RLD 12/1002 20 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION 020110 ISSUED FOR REVISED CONSTRUCTION BAY soi it CONSTRUCTION SFOR EVISEO RLD 02j120 ISSUED FO SEO CONSTRUCTION PROJECT: SEAQ- PONCHO S. 1091H & BEACON AVE S. TUKWILA, WA 98178 E-3 V ip a 0 62, O. / 2' � ►lII e °. 0 LEGEND I- COPPER GROUND BAR)'. 'X 4 % 20', NEWTON INS-RUNENT CO. CAT. N0. D-6142 OR EQUAL. HOLE CENTERS TO MATCH .NENA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE ((ALL VARY BASED ON NUMBER OF GROUND CONNECTIONS) 7- INSUUITORS. NEWTON INSTRI61NENT CAT. NO. 3C - 0R EQUAL 3- 5/9" LO KWASHERS, NEWTON INSTRUMENT CO. CAT. NO c3015-9 OR EQUAL 4- WALLNG BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR MUM. 5- 5/B-11 X 1' HHCS BOLTS, NEWTON INSTRUMENT CO. CAT .3012-1 OR ECUAL 6-INSULATORS SHALL BE ELNUINATE0 WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE. CONNECTION TO TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. OTYPICAL GROUND BAR DETAIL ACT TO SCALE L PNT COLLAR 04TTH �µL TEFLON LUBFCANT OF IL" ISHED GRADE TMFSi RADE 30'M� 1---COPPEERGR lVWITH un FNLEADAPTER & SCREW EW LEB GROUNDING CONDucioORE TINNED EXOTHERMIC 'HELD (THfRMO'WELD OR Ou:VAL.') DIRECTLY TO OF GROUND ROD M2 SCUD, BARE RCOPPER GROLL D RING W!OE SLOT. 1YP1CAL FOR 2. 2'OVE GROUND EXTEND RING (a" CAL) STEEL C� W EEL GROUND R TEST WELL ®GROUND NOT TO BULL USED ONOT NOT TO SCALE W/ Y �'���r GRADE OR ST BELOW WELD F O N MDC 0 O�,VW:. J�.0.0, ELsoLO TN.vco cu rx Al \ N \�1 `��! DrvC BUR ED CROUNDrRNG p\AO1 JAW E%OTHERV GALLEY ND (tt ROD GROUND ND ROD ROD (TYPICAL) \`PICAL) ITROR DROuNO RING /] AwG Bcw RCOO CO PEONRWGELO /eUVOA A -0' EXTERIOR GROUND RING DETAIL ® GROUND ROD DETAIL CAR NOT TO SCARE VP nor TO SCALE NOTES 1. ° CABLE DIRECT TGROUND WIRE 2. WEATHER PROOFINGSHALL AS SUPPLIED CRRECONNENDED JuMPECABLE ONLY4 RfCUIREO Sin FOR I F/9'r coAx OR R OR EASE CONNEOCF MA) roN CONNECTOR wA HERPROOFINC KITE (NOTE 2 GROUND MT AT A BEND ANO ALWAYS OOwN TO ANTENNA GROUND BAR. BE ANCREwS. (TYPE & NUMBER E• CABLE MANUFACTURER.) TO ANTENNAS RXI 0 NITATHERPR00FINC survoARo GROUNDTTNECYOAND KIT (TYP,) (SEE NOTE) ANTENNA CABLE TO sHFLTER (PP.) GROUND '1' l0 1i ANTENNA CABLE WEATHERPROOFING NIT , 3) 2 1/21.A MAX. (SEE NOTE GROUND Kir w6 ANC STRANDED COPPER GROUND IRE (GROUNDED TO GROUND BAR) (SEE NOTE I & 2) IN OF CABLE GROUKIT TO ANTENNA CBLE (SOTO I. DOANTFANN 2. GTH OLE LUG. 3 WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. IAIED BONDED TOP OF MONOPOLE. TOWERS rE EL TONER OR wAVEGuIOE LADDER. M NO L AiANTENNA GROUND BAR GROUNDING DETAIL NOT 0 SCALE ®CABLE GT TO SCALE EOM ELECTRICAL OETALS AND PLANS SHALL BE REV.EWEO BY SEATTLE CITY LIGHT ELECTRICAL ENG,NEERlNG. at NOT USED SEATTLE CITY LIGHT NOTE ' NOr 70 SCALE O NOT TO SCALE OE THICKNESS OF EXISTING COMPACTED BACED .WAD MI DENSITY R AS. 01557 METHOD D UNDISTURBED EARTH CONDUIT 19' MINIMUM p=11Pll�ll1ll=11�alR1� ` G ® o rI 1iLILITY WARNING 2, POwER CONDLRT B0CKFILL (SAND OR 5A11vE SOIL) OPOWER/TELEPHONE TRENCH DETAIL NCi ra SUE STRANDED CU WIRE WITH GREEN, NSULATION. SIZE ASHSP C.FIEO GROUND BAR ON WALL FLOOR OR ON ANTENNA TOWER TWO -HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1/4"STAILESS STEEL HEAD BOLTS D HARDwARE�EX • GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE E%OTHERWC CONNECTION. GROUND BAR CONNECTION NOT TO SCALE .TWO -HOLE LUG, TO BE USED WI H #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WTH GREEN, E00V, THHN/THwN INSUTA'ICN TO ANTENNA STRUCTURE BUILDING RNG GROUND OR NCB UTILITY RACK DETAIL 6 TO SCALE PLANS PREPARED FOR: PLANS PREPARED BY: IOWA, MIFF NW • M MI PI II 1 t•R R. II 1 ■■■II .1111 1 1 KDC ARCHITECTS.ENGINEERS. P.C. >M ICOTR STREETWA9fl SW STIRS 200 IYNNW000• WA 99036 4 FAX 4I5.311.01 LICENSURE: 5773 I REGISTERED I ARCHITECT OF WASHINGTON DATE: 04/20/2011 DRAWN BY: HLU CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY IozED FOR 2010 00 CD REVIEW RLo 12/G2 1010 ISSUED FOR CONSTRUCTION 11/21 2010 VTSED CONSTRUCTION BAH JPM C2015 CONSTRUCICrSED 01/31 ISSUE° FOR REVISED RLD� Q2011 CONSTRUCTION AP DAH 2021 SSJED FOR CONSTRUCTION�SEO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUNWII A. WA 98178 E-4 VERIZON WIRELESS L11-028 WIRELESS COMMUNICATION FACILITY City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 21, 2011 NOTICE OF DECISION TO: Bill North, Applicant Seattle City Light, Owner King County Assessor, Accounting Division Washington State Department of Ecology This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: Ll 1-028 (Wireless Facility Permit) Applicant: Bill North, The North Group on behalf of Verizon Wireless Type of Permit Applied for: Type 1 Wireless Communications Facility Permit Project Description: Request for approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to upgrade an existing wireless telecommunication facility. Upgrades proposed include replacement of 6 panel antennas on the tower with 12 new panel antennas, and the addition of 6 new ground -mounted equipment cabinets which are proposed to be located within a new enclosure at the base of the tower. The proposed equipment enclosure will be a 6-foot high chain link fence with privacy slats. Location: Seattle City Light electrical transmission right-of-way located north of the intersection of S. 109th St. and Beacon Ave S. (parcel number 687420-1170). Associated Files: PL11-021 (Project File); E11-009 (SEPA/Environmental Review) Comprehensive Plan Designation/Zoning District: Low Density Residential (LDR) II. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that the project, as proposed, does not create a probable significant environmental impact and issued a Determination of Non -Significance (DNS). Decision on Substantive Permit: The City Community Development Director has determined that the application for a Type 1 Wireless Telecommunications Facilities Permit does comply with applicable City and state code requirements and has approved that application, subject to the following conditions: 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1. The new enclosure, as shown on plans, is larger than 360 square feet. Per the applicant, the proposed enclosure is only meant to be 300 square feet. As a condition of approval, the correct size of the enclosure on the building permit plan set be shown and reviewed for compliance with the maximum allowable area of 360 square feet. 2. The color of antennas proposed with this project is not indicated on plans. As a condition of approval, the new antennas shall be painted to match the color scheme of the tower. 3. The color of the coaxial cables proposed with this project is not indicated on plans. As a condition of approval, feed lines and coaxial cables shall be painted to match the color of the tower. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision; that is, by December 5, 2011. The requirements for such appeals are set forth in Tukwila Municipal Code Ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing parry's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee per the current fee schedule, additional hourly charges may apply. In addition all hearing examiner costs will be passed through to the appellant. Page 2 of 3 V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW Ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The _City' s decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Jaimie Reavis, who may be contacted at 206-431-3659 for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Department of Community Deopment City of Tukwila Page 3 of 3 ea* of J ufuu iea Department Of Community Development AFFIDAVIT OF DISTRIBUTION I, Jaimie Reavis HEREBY DECLARE THAT: Notice of Public Hearing Determination of Non -Significance Notice of Public Meeting Mitigated Determination of Non - Significance Board of Adjustment Agenda Packet Determination of Significance & Scoping Notice Board of Appeals Agenda Packet Notice of Action Planning Commission Agenda Packet Official Notice Short Subdivision Agenda Notice of Application Shoreline Mgmt Permit Notice of Application for Shoreline Mgmt Permit _ — FAX To Seattle Times Classifieds Mail: Gail Muller Classifieds PO Box 70 - Seattle WA 98111 Other: Notice of Decision Was mailed to each of the addresses listed/attached on this 2I day of November in the year 2011. Mailed to list of recipients on Notice of Decision, except Notice of Decision sent to DOE by email. Project Name: Verizon SEAQ PONCHO at S. 109th St. and Beacon Ave. S. Project Number: L11-028 (WCF Permit), PL11-021 (Project File Number) Mailing requested by: Jaimie Reavis Mailer's signature: w/j//. 4J ji H:\Wireless Telecommunication Facilities\PL11-021_L11-028_Verizon_Type 1_SEAQ PONCHO\L11- 028_Verizon_SEAQ_PONCHO_Affidavit of Distribution.doc City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTIFICATION: FILE NUMBER: APPLICANT: OWNER: REQUEST: LOCATION: ASSOCIATED PERMITS: SEPA DETERMINATION: COMPREHENSIVE PLAN DESIGNATION: ZONE DESIGNATION: STAFF: ATTACHMENTS: STAFF REPORT TO THE DIRECTOR PREPARED November 17, 2011 Notification was mailed to property owners and tenants within 500 feet of the transmission tower, as well as by a notice board posted installed on site. L11-028 (Wireless Facility Permit); PL11-021 (Project File) Bill North, The North Group on behalf of Verizon Wireless Seattle City Light Approval of a Type I Wireless Telecommunication Facilities Permit to upgrade an existing wireless telecommunications facility located on an electrical transmission tower, including new equipment proposed within a new equipment enclosure located at the base of the transmission tower. Seattle City Light electrical transmission right-of-way located north of the intersection of S. 109th St. and Beacon Ave S. (parcel number 687420- 1170). E11-009 (SEPA/Environmental Review) A Determination of Non -Significance was issued for this project on September 20, 2011. Low Density Residential (LDR) Low Density Residential (LDR) Jaimie Reavis, Assistant Planner Project Plans for Permit L11-028, including redlined sheet A-2. FINDINGS Vicinity/Site Information Project Description The applicant is requesting approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to upgrade an existing wireless telecommunication facility. Upgrades proposed include replacement of 6 panel antennas on the tower with 12 new panel antennas, and the addition of 6 new ground -mounted equipment cabinets which are proposed to be located within a new enclosure at the base of the tower. The proposed equipment enclosure will be a 6-foot high chain link fence with privacy slats. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 I Existing Development The project site is part of a large parcel that is Seattle City Light electrical transmission right-of-way. There are several other towers within this parcel, which extends through the Ryan Hill Neighborhood east -west from Beacon Ave. S. to an area just west of 47th Ave. S. Development on the parcel within the immediate vicinity of the transmission tower included in this application includes the transmission tower and an existing equipment enclosure located at the base of the tower. Surrounding Land Uses The property and all adjacent parcels are zoned LDR. Development to the north and south consists of single-family homes; the area to the west is Seattle City Light right-of-way developed with transmission towers and associated transmission lines; the site is bordered on its east side by Beacon Ave. S., beyond which is a narrow strip of undeveloped land and 51' Ave. S. BACKGROUND In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.58) to the Zoning Code. The chapter provides specific location and design requirements for the placement of WCF within the City of Tukwila. The WCF being modified was originally approved by the City in 1998 (L98-0011) through a conditional use permit. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co - locations and utilizing existing structures are favored over the development of new standalone WCF within the City. TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility ZONING (1) TYPE OF FACILITY RESIDENTIAL COMMERCIAL INDUSTRIAL Transmission Tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower Type 1(2) Type 1(2) Type 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2(3) Type 2(3) Type 2(3) Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 4 Type 4 Type 4 Page 2 of 6 (1) Zoning for any private/public property or right-of-way Residential — LDR, MDR, or HDR Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS Industrial - LI, HI, MIC/L, or MIC/H (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Table 1 Specific Design Standards Project Project does Not Applicable does comply not comply 1. Generators must comply with TMC 8.22 regarding noise. The applicant has not proposed a generator. 2.Business License Requirement The applicant has applied for a business license at this location. 3. Only safety signage must be placed on the WCF The applicant does not propose any signage. Parking is not affected by this modification. 4. Accommodations for parking for maintenance personal must be provided. 5. Towers shall either maintain a galvanized steel finish or be painted a neutral color so as to reduce its visual obtrusiveness. Existing tower will maintain its galvanized steel finish. 6. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. The new equipment enclosure, constructed of a chain link fence with privacy slats, will match the existing enclosure. 7. Antennas shall have the same color scheme as the structure they are located on. The new antennas will match existing antennas located on the transmissions tower. 8. WCF poles and towers shall only have safety lights if required by a government agency. No lighting is proposed. 9. No advertising is permitted on WCF No advertising is proposed. Page 3 of 6 0' 10. Each service provider shall be limited to an equipment enclosure of 360 square feet. The new enclosure, as shown on plans, is larger than 360 square feet. Per the applicant, the proposed enclosure is only meant to be 300 square feet. As a condition of approval, the correct size of the enclosure on the building permit plan set be shown and reviewed for compliance with the maximum allowable area of 360 square feet. 11. In residential zones, the height of the replaced utility pole is limited to 10 above the replaced pole and no taller than 50. This is not a utility pole facility. 12. The replaced utility pole must be used by the owner of the utility pole to support their utility lines. This is not a utility pole facility. 13. The replaced utility pole must have the color and general appearance of the adjacent utility pole. This is not a utility pole facility. 14. Coaxial cables greater than one-half inch in diameter must be within the utility pole. This is not a utility pole facility. 15. The proposal shall not result in a significant change in the pedestrian environment or preclude the City from making pedestrian improvements. The proposed modifications will not affect pedestrian facilities. 16. All cabinet equipment must be placed outside of the City ROW, unless an exception is granted. The cabinet equipment is not located in City ROW. 17. The WCF shall meet setbacks for the zone in which it is locate, unless an exception is granted. The transmission tower under which the new equipment cabinet is proposed to be located is set back from the front property line approximately 10 feet. The front setback requirement in the LDR zone is 20 feet. The new equipment enclosure will be located underneath the transmission tower, and will not expand beyond the existing encroachment into the front setback area. Page 4 of 6 18. When adding antennas to existing WCF towers, height must not exceed what was approved under the original application to construct the tower. The height remains the same as that approved previously. 19. Antennas shall be painted to match the color scheme of tower. The color of antennas proposed with this project is not indicated on plans. As a condition of approval, the new antennas shall be painted to match the color scheme of the tower. 20. Feed lines and coaxial cables shall be located within the tower. Those exposed shall be painted to match tower. The color of the coaxial cables proposed with this project is not indicated on plans. As a condition of approval, feed lines and coaxial cables shall be painted to match the color of the tower. 21. A new cabinet shall be located within the equipment enclosure that was approved as part of the original application. A new equipment enclosure is proposed for this project, inside which the new cabinets are proposed to be located. CONCLUSIONS 1. The proposed antennas, equipment cabinets and enclosure are co -located at an existing transmission tower facility, the most favorable type of facility in the list of different types of Wireless Telecommunications Facilities listed in Table A. 2. Table 1 provides information on how the project meets most of the applicable development standards. As shown in Table 1, this project does not comply with development standards outlined in rows 10, 17, 19, and 20 in Table 1. A description of each of these items is below, with either a recommended condition of approval to ensure the project will meet these development standards upon project completion, or an explanation for how the project still meets the development standards: "Project Does Not Comply" - Items from Table 1: (10) Each service provider shall be limited to an equipment enclosure of 360 square feet. The new equipment enclosure as shown on plans is larger than the maximum allowable size of 360 square feet. Per discussions with the applicant by phone, the size of the equipment enclosure shown on project plans is incorrect. The equipment enclosure is only planned to be 300 square feet. Staff recommends approval of the application, with the condition that the correct size of the enclosure on the building permit plan set be shown and reviewed for compliance with the maximum allowable area of 360 square feet. Page 5 of 6 (17) The WCF shall meet setbacks for the zone in which it is located, unless an exception is granted. The transmission tower under which the new equipment cabinet is proposed to be located is set back from the front property line approximately 10 feet. The front setback requirement in the LDR zone is 20 feet. The new equipment enclosure will be located underneath the transmission tower, and will not expand beyond the existing footprint of the transmission tower. (19) Antennas shall be painted to match the color scheme of tower. The color of antennas proposed with this project is not indicated on plans. As a condition of approval, the new antennas shall be painted to match the color scheme of the tower. (20) Feed lines and coaxial cables shall be located within the tower. Those exposed shall be painted to match tower. The color of the coaxial cables proposed with this project is not indicated on plans. As a condition of approval, feed lines and coaxial cables shall be painted to match the color of the tower. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation, building or site design. 4. No noise will be generated from the new antennas and equipment cabinets being installed. 5. The wireless communications facility has been designed in a way to minimize any visual impact from the project. 6. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type I Wireless Telecommunication Facility permit as applied for by Verizon Wireless with the following conditions: 1. The new enclosure, as shown on plans, is larger than 360 square feet. Per the applicant, the proposed enclosure is only meant to be 300 square feet. As a condition of approval, the correct size of the enclosure on the building permit plan set be shown and reviewed for compliance with the maximum allowable area of 360 square feet. 2. The color of antennas proposed with this project is not indicated on plans. As a condition of approval, the new antennas shall be painted to match the color scheme of the tower. 3. The color of the coaxial cables proposed with this project is not indicated on plans. As a condition of approval, feed lines and coaxial cables shall be painted to match the color of the tower. Page 6 of 6 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director TECHNICAL COMMENTS Sent via email to Bill North at billnorth@northgroup.net (no hard copy to follow) September 23, 2011 Bill North P.O. Box 2449 Snohomish, WA 98291 RE: L11-028 Verizon Wireless SEAQ PONCHO (Seattle City Light right-of-way north of Beacon Ave S and S. 109th Street) Dear Mr. North, On September 20, 2011 the City of Tukwila issued a SEPA Determination of Non -Significance under permit number E11-009 for the project referenced above. The Wireless Permit (L11-028) is still pending approval, and cannot be issued until a business license is submitted for operation of the wireless facility. At this time, no business license application has been submitted for operation of a wireless facility at the project location. In order to process your permit application, please contact the City of Tukwila Finance Department for business licensing requirements. You can access the fee schedule and download an application at http://www.ci.tukwila.wa.us/finance/buslic.html. This application may expire if we do not receive the additional information within ninety days of the date of this letter unless an extension is granted pursuant to Section 18.104.070(E). After review of your business license submittal, the Wireless Communication Facility permit will be ready to issue. If you have any question, please contact me at 206-431-3659 or via email at Jaimie.Reavis@TukwilaWA.gov. Regards, ZG m Jaimie Reavis Assistant Planner JR Page 1 of 1 09/23/2011 H:\Wireless Telecommunication Facilities\PL11-021_L11-028_Verizon_Type 1_SEAQ PONCHO\L11-028_Technical Comments_Business License.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTICE OF INCOMPLETE APPLICATION May 17, 2011 Mr. Bill North P.O. Box 2449 Snohomish, WA 98291 RE: Verizon Wireless Communication Facilities Permit at S. 109th Street and Beacon Ave S (parcel #687420-1170) L11-028 (Wireless Permit Number), PL11-021 (Land Use Project Number) Dear Mr. North: Your application for a Type 1 Wireless Communication Facilities Permit located on an existing transmission tower in the vicinity of S. 109th Street and Beacon Ave S in Tukwila (parcel number 687420-1170) has been found to be incomplete. In order to be a complete application, the following must be submitted to the permit center: a. The proposal to add new wireless service antennas to an existing structure located within a residential zone does not appear to meet the SEPA exemption requirements of the Washington Administrative Code (WAC) section 197-11-800 (27). Please submit a SEPA application (see attached) and application fee ($1,490.00). b. Please indicate whether a generator is proposed as part of this project. Upon receipt of these items, the City will re -review them for completeness and will mail you written notification of completeness or incompleteness within 14 days. These applications will expire if we do not receive the additional information within ninety days of the date of this letter unless an extension is granted pursuant to Section 18.104.070(E). If you have any questions with this matter you may call me at (206) 431-3659. Sincerely, 410,7", J ' e Reavis Assistant Planner Enclosure: SEPA Permit Application cc. PL11-021, L11-028 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 *Phone 206-431-3670 • Fax 206-431-3665 RECt__ J! D C1T f1R7?L41,1 1 Depa inmnityDevelopment WIRELESS TELE- 6300 Sentue iioulevard, Tukwila, WA 98188 COMMUNICATION Telephone: (206) 431-3670 FAX (206) 431-3665 FACILITIES E-mail: tukplan@ci.tukwila.wa.us APPLICATION FOR STAFF USE ONLY Permits Plus Type P-WCF Planner: :I Vvi , e is Application Complete (Date: Application Incomplete (Date: File Number: L— Project File Number:3 L t (,--ND,,t Other File Numbers: NAME OF PROJECT/DEVELOPMENT: �. --P©►`?c-O LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant. indicate lot(s), block and subdivision, access street, and nearest intersection. LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 1-12,n___ o DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: � t l_.L_, h, 6 1 L ti Address: /6 �, �-+ 1 c5 �t ‘&r t �l ! q 1 Phone: �' f "2-c • --G7 V� - l 49 FAX: (1'25---7 1 • d g6q. E-mail: .• 11 114 r n o r ro V p • Signature: Date: •- 4, C: \ DOCUME-1\ SCOI 1--1.TUK\LOCALS-1 \ Temp \XPGrpWise\ Wireless Communication Facility-Jan2011.doc COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. t/' 1. Application Checklist (1 copy) indicating items submitted with application. \/ 2. Completed Application Form and drawings (5 copies). 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8.5" by 11". Plans shall be no greater than 24" x 36". t/ 4. Application Fee: See Land Use Fee Schedule. 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). NiJii ' 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an exiting structure that is not a residence or school and does not contain a residence or a school; ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or agricultural zone. ` V 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements. i,/ f A. 8. Sensitive Area studies and proposed mitigation (if required). A, 1`�ik 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Chapter 8.22, "Noise". C:\DOCUME-1\SCUI 1--1.TUK\LOCALS-1\Temp\XPGrpWse\tireless Communication Facility-Jan2011.doc CITY OF TC: K11 IC.A Deportment of Community (Development 6301 Smithy -enter lain,( 'rwd, "Tukwila►, 9818 Telephone. t'Ott) 131 3t 71) FAX (20!,, 43/-3665 !-inaif, tuk an(ckchtuk1;-il<i.wzt.us AFFIDAVIT Of -OWNERSHIP AND HOLD HARM 1.F.SS PERMISSION TO ENTER I'i&O1'ERT1>" StAF( Lt \SII1N(:CJ0' CU1 "N I ]' OF 1 NC t'hr utidctrsigned being duly sw n' and rpxrtt trath,st.ttes as fuI I.n s: RECEIVED ►A n 21 20111 DEVELOPWIEAT 1 l tm the eurent ow tter of the property which i, the subject of this application. 2 All statements contained in the ,npplicat;tms hare been prepared by me or my a rnt, :mil ;,rt true .,nti cr,rect to the hest of my knov, ledge. the application Is being submitted with my knowledge and consent. re :cw. for the limited tune necessary to complete that purpose. Owner agrees to bald the City harrrilcs, for any loss or damage to per was or pri pert) occur r irrg on the pi is ate [noperty during :he Cit.) "s entry upon the property. unless the loss or damage is the result of the sole negligence of the City. h. s•on.respe+n. rvene , to a Crts intarntati.rn request for ninety (90) or more days. shall be cause to cancel tltc aplzlcation( s) without re fund at tee; .Ct'tt.l)t Seattle l.1 t )fit ner grants the City, in eunplctyee . agents. engirt:cr s. eotttracta: s of otltct Apr escnt;rti t es the rr ht tc, enter upon ()cc ner', real propem, iocatec', at S . 109th St . & Beacon Ave._ 5 . , Ttikwi la fi r the purpose ot'applicati rrt (eta) W (state). on Agri l 13 St.evF Crunye \ SPar.tie. :- ty r„ght- (Print Name) (Addis s)' (I'htnie Nutnbet) tSiguarute) 2() 11; 3613 4th Ave S.,S7, Seattle, WA 98134 206-615-138S day personally appeared before ire S e e w :: urne ett•Lute(: t,ne tctrecoing instrument and tcknowtedged dim tc sht stoned the ::.tar purposes sn.entiemed t'tereln to me knaa:r to be the irtdic idual a Ito Cis his he; tt'lt.rrtar\ aet and deed for the uscs and titT3St.'R131.1) ANI) S VI)RN TO BEFORE ME ON "('HIS 19th 1).AY OF Aftz: .1 resittingatt Shore ne, N11 C unilrttictirort;esprres ors Sept:. etttktc? r' 2 Ot.:'t , 2 "'tt 11 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htq)://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6874201170 Permit Number: L11-028 Address: Status: PENDING Suite No: Applied Date: 04/21/2011 Applicant: VERIZON WIRELESS Issue Date: Receipt No.: R11-00774 Initials: TLS User ID: 1684 Payment Amount: $515.00 Payment Date: 04/21/2011 01:35 PM Balance: $0.00 Payee: KDC ARCHITECTS ENGINEERS PC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6076 515.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ZONING/SUBDIVISION 000.345.810 515.00 Total: $515.00 doc: Receiot-06 Printed: 04-21-2011 Application for Wireless Communications Facility VERIZON WIRELESS SEAQ Poncho A Proposal Submitted to City of Tukwila Prepared for Verizon Wireless 15900 SE Eastgate Way Bellevue, WA 98008 Prepared by The North Group, Inc. Bill North PO Box 2449 Snohomish, WA 98291 April 20, 2011 I. PROPOSAL SUMMARY INFORMATION Verizon Wireless Site: SEAQ Poncho Applicant: Prepared By: Verizon Wireless 15900 SE Eastgate Way Bellevue, WA 98008 The North Group, Inc. Bill North PO Box 2449 Snohomish, WA 98291 425-876-2909 billnorth a(�northgroup.net Property Owner: Seattle City Light Request: Site Location: Assessors Parcel Number: R CE!V ) 'APR 21 20111 COMMUNt r( DEVELOPMENT Approval of a Type I Wireless Facilities Permit and Building Permit for a Wireless Communication Facility. S. 109th St. and Beacon Ave. S. Tukwila, WA 98188 687420-1170 Zoning: LDR Low Density Residential 2 II. INTRODUCTION Verizon Wireless ("Verizon Wireless") is a wireless communications company operating in City of Tukwila, Washington. Verizon Wireless is licensed to operate in the State of Washington by the Federal Communications Commission (FCC). Verizon Wireless is currently designing its network in Washington to improve its wireless communication service and provide wireless capacity to its subscribers. This proposal describes the scope of the proposed project by providing specific information regarding the project location, zoning, specifications, and response to City of Tukwila code requirements pertaining to Wireless Communications Facilities (WCF). It is Verizon Wireless's desire to work with City of Tukwila to ensure that our project is consistent with local ordinances and zoning regulations while providing the wireless communications coverage that is critical for emergency, business, and personal use. Project Goals The goal of the Verizon Wireless Facility is to provide wireless communications coverage for personal and emergency purposes in the immediate area of the project and vicinity. Verizon Wireless intends to achieve these network goals consistent with all policies and ordinances of City of Tukwila. Application Request The applicant is requesting the following: Approval of a Type I Wireless Facilities Permit and Building Permit for a Wireless Communication Facility. III. PROJECT DESCRIPTION Project Overview Verizon Wireless, the applicant is proposing to replace 6 panel antennas on an existing Seattle City Light (SCL) electrical transmission tower with 12 new panel antennas along with the addition of 6 ground mounted equipment cabinets. The existing SCL tower is located at S. 109th St. and Beacon Ave. S. Tukwila, WA 98188 and identified as A.P.N. # 687420-1170. The equipment cabinets will be placed below the tower and will include perimeter fencing. Zoning General Plan Designation The site is located on property zoned LDR Low Density Residential. The City of Tukwila code references Wireless Communications Facilities in TMC Chapter 18.58. The proposal is classified as an "Electrical Transmission Tower Co -Location" (18.58.080). This proposal is permitted with a Type I Wireless Facilities Permit and Building Permit. Existing Use 3 Seattle City Light Electrical Transmission Tower with existing Wireless Communication Facilities. Traffic There are no traffic impacts associated with these types of facilities as they are unmanned and require infrequent maintenance. A parking area is provided. FCC/FAA Verizon Wireless is licensed to operate in the State of Washington by the Federal Communications Commission (FCC). Verizon Wireless will conform to all FAA/FCC regulations as well as all other applicable federal, state, and local laws, rules, and regulations. Please see attached FCC license. IV. City of Tukwila Wireless Communication Facility Design Standards Section 18.58.080 of City of Tukwila code has specific requirements for wireless communication facilities located on transmission towers. The following addresses each of the requirements in the order they appear: 1. Height — There is no height requirement for antennas that are located on electrical transmission towers. Response: The antennas will be located on the tower at approximately 50'. No height increase is proposed. 2. Antenna aesthetics- There are no restrictions on the type of antennas located on the electrical transmission tower. The antennas must be painted to match the color of the electrical transmission tower. Response: The attached antennas will be painted to match the color of the tower in compliance with this section. 3. Antenna aesthetics— There is no limit on the number of antennas that may be located on an electrical transmission tower structure. Response: Verizon proposes to locate 12 antennas on the tower. 4. Feed lines and coaxial cables— shall be attached to one of the legs of the electrical transmission tower. The feed lines and cables must be painted to match the color of the electrical transmission tower. Response: Verizon will place 18 coaxial cable on one leg and paint to match the color of the electrical transmission tower. 5. Cabinet equipment— Cabinet equipment shall be located directly under the electrical transmission tower where the antennas are located or a concealed location. The wireless communication equipment compound shall be fenced; the fence shall have a minimum height of 6 feet and a maximum height of 8 feet. The fence shall include 4 slats, wood panels, or other materials to screen the equipment from view. Barbed wire may be used in a utility right-of-way that is not zoned residential. Response: The equipment cabinets will be placed below the tower within a 20'x30' fenced area with privacy slats. 6. Setbacks— Since the facility will be located on an existing electrical transmission tower, setbacks shall not apply. Response: Not applicable. Summary: The proposed Verizon Wireless Communication Facility meets the requirements of the City of Tukwila Code 18.58.080. We appreciate the opportunity to make our proposal and to provide quality wireless communication services to the residents of the City of Tukwila. Sincerely, Bill North The North Group, Inc on behalf of Verizon Wireless. 5 SHEET INDEX ARCHITECTURAL T-1 TITLE SHEET A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN & PROPOSED ANTENNA LAYOUT A-3 NORTH & EAST ELEVATIONS A-3.1 SOUTH & WEST ELEVATIONS A-6 DETAILS 1 AI \ ELECTRICAL E-1 ONE LINE DIAGRAM, ELECTRICAL NOTES E-2 ELECTRICAL SITE PLAN E-3 ELECTRICAL GROUNDING PLANS (SCHEMATIC) E-4 DETAILS PROJECT DIRECTORY APPLICANT; VERIZON WIRELESS 15900 SE EASTGATE WAY M/S 231 BELLEVUE, WA 98008 APPLICANT AGENT; KDC ARCHITECTS, ENGINEERS P.C. 4720 200TH STREET SW., SUITE 200 LYNNWOOD, WA 98036 CONTACT: BILL NORTH PHONE: (425) 876-2909 FAX: (425) 671-0862 ARCHITECT/ELECTRICAL ENGINEER: KDC ARCHITECTS, ENGINEERS P.C. 4720 200TH STREET SW., SUITE 200 LYNNWOOD, WA 98036 CONTACT: ERIC CAMP PHONE: (425) 670-8651 FAX: (425) 712-0846 PROJECT INFORMATION WASHINGTON STATE CODE COMPLIANCE. 2009 IBC, STANDARDS AND AMENDMENTS—WAC 51-50; 2009 IMC, STANDARDS AND AMENDMENTS—WAC 51-52; 2009 IFC, STANDARDS AND AMENDMENTS—WAC 51-54; 2009 IPC, STANDARDS AND AMENDMENTS—WAC 51-56, 51-57. SITE NAME: SEAQ—PONCHO SITE ADDRESS; S. 109TH & BEACON AVE S. TUKWILA, WA 98178 LAND OWNER; SEATTLE CITY LIGHT 3613 4TH AVE. S., S-7 SEATTLE, WA 98134 PHONE: (206) 733-9138 JURISDICTION: CITY OF TUKWILA PARCEL NUMBER: 687420-1170 PROJECT DESCRIPTION; THIS PROPOSAL IS FOR THE INSTALLATION OF (6) VERIZON WIRELESS OUTDOOR EQUIPMENT CABINETS MOUNTED ON A CONCRETE PAD WITHIN A 20'-0" X 30'-0" FENCED LEASE AREA. ALSO THE ADDITION OF (12) VERIZON WIRELESS ANTENNAS MOUNTED AT AN EXISTING 125'-6"± HIGH TRANSMISSION TOWER. verin wireless SEAQ-PONCHO 10581 BEACON AVE S SEATTLE, WA 98178 SCL TOWER#: DU 2/7S LAT: 47° 30' 21.32"N LONG: 122° 16' 14.38"W ELEV: 278.6' AMSL LEGAL DESCRIPTION POTTERY WORKS ADD C OF S TRAN LN R/W OVER ADD CONTRACTOR NOTE THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE J09 ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING IN WRITING THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF ISCREPAN IES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. GENERAL NOTES 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, AND THIS SET OF PLANS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANYTHING ELSE DEEMED NECESSARY TO COMPLETE INSTALLATIONS AS DESCRIBED HEREIN. 2. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE NEW PROJECT, WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS, FIELD CONDITIONS AND CONFIRM THAT THE PROJECT MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY ERRORS, OMISSIONS, OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING. 3. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/ VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 6. ALL WORK PERFORMED ON PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 7. THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 8. ANTENNA SUPPORTING POLE IS UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION SUB —CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUB —CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF PERSONNEL AND PROPERTY FROM HAZARDOUS EXPOSURE TO OVERHEAD DANGERS. 9. GENERAL CONTRACTOR SHALL PROVIDE AT THE PROJECT SITE A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR THE USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. 10. DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SCOPE OF WORK. 11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION UPON COMPLETION OF WORK. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12. CONTRACTOR SHALL ENSURE THE GENERAL WORK AREA IS KEPT CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY, PREMISES SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. APPROVALS/ISSUE DATES SITE ALPHA NO: DATE ISSUED AS Preliminary Preliminory—Revised Zoning —Special Use Permit Application Construction Permit Application Issued for Zoninq/Construction Issued for Construction Issued Zoning & Construction Permit As Built/Record Set For Owner and Engineering Approval VERIZON WIRELESS CELLULAR DESIGN ENGINEER APPROVAL PRINTED NAME SIGNATURE TITLE DATE VERIZON WIRELESS PROPERTY OWNER APPROVAL PRINTED NAME SIGNATURE TITLE DATE SITE PERSPECTIVE 7 7 7 7 7 7 .7 7 7 7 7 SYMBOLS LIST E E ELEVATION NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER —T T - -G G— [N] NEW [E] EXISTING PROPERTY LINE ELECTRICAL SERVICE TELCO SERVICE GROUNDING ELECTRIC METER _ ^ ELECTRICAL WIRING V ` (TURNING UP) _ ^ ELECTRICAL WIRING LV ` (TURNING DOWN) I 1 BACKBOARD RECEPTACLE SPECIAL RECEPTACLE OUADRAPLEX RECEPTACLE MASTER GROUND BAR GROUND ATTACHMENT DRIVING DIRECTIONS FROM SEATAC INTERNATIONAL AIRPORT' DEPART SEATTLE—TACOMA INTERNATIONAL ARPT—NORTH ENT ON LOCAL ROAD(S) (NORTH—WEST) TAKE RAMP (RIGHT) ONTO SR-518WA-518 / 1-5 / 1-405 SEATTLE / TACOMA TAKE RAMP (LEFT) ONTO 1-51-5 / SEATTLE AT EXIT 157, TAKE RAMP (RIGHT) ONTO SR-900 [MARTIN LUTHER KING WAY S]M L KING WAY TURN RIGHT (EAST) ONTO S RYAN WAY TURN RIGHT (SOUTH) ONTO 51ST AVE S TURN RIGHT (WEST) ONTO S 109TH ST ARRIVE 10581 BEACON AVE S, SEATTLE, WA 98178 CONFIDENTIAL AND PROPRIETARY Not for disclosure outside VERIZON WIRELESS without permission. VICINITY MAP =41 8'. SeattleT S Runlet. St ‘:4, •:9' I _.. S-1NLA .BangorSr— — a I I.S Fountain' St rw. 1 18 S Rya —5Awn-St. '9ta S. F PLANS PREPARED FOR: irvc O ver% Imnwireless PLANS PREPARED BY: Nomp. — ppw pa, R, Mal MI _ II I[[ NU III 111 III 0 11 1 _ KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD. WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 i 1 I LICENSURE: 5773 REGISTERED ARC TECT KENNETH D. CAMP STATE OF WASHINGT DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISEDws CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 pROPEWrg LNE PROPERTY LINE 1 a a / PROPar7 LINE PROPERTY LINE PROPERTY LINE / OVERALL SITE PLAN SCALE FOR 24x36: 1"= 50'-0" SCALE FOR 11X17: 1" = 100.-01 PROPOSED PROJECT AREA SEE ',. APN: 687420-1170 0 50' 100' 25' 75' NORTH PROPER E1/ 0 w 0 GENERAL NOTES: DIG NOTE' CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 1-800-424-5555 GENERAL NOTES' REFER TO T-1 & 2/A-5 FOR GENERAL NOTES. — OH OH S 109TH ST ktia-62( PLANS PREPARED FOR: n� ` L. �, •� Z11/li 24 0r ■i iij 01 PLANS PREPARED BY: mum mom mu, wr S IN I II MINIM Ili IF M B 1 • • 5 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200111 STREET SW SUITE 200 LYNNWOOD. WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 1 R 1 I LICENSURE: 5773 REGISTERED ARCHIT CT t NN TH O. C'1 STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 OH 0 i I 0 1 I 0 — — PROPERTY LINE 148.r90't — — OH OH OH "t FO ,PROPOSED ANTENNAS 0H OH% APN: 687420-1170 — 1 ' ERN a 0 0 re 0 a 0 i44 Of sue; U; l61'`�_'1��1 � 1 0 1 1. 0 — — (SCALE FOR 24x36: 1"= 20'-0" SCALE FOR 11X17: 1" = 40'-0"I 10' 20' 1 CO 4CO 30' 40' PROPERTY LINE N O R T H 0H OH KEYED NOTES O1 EXISTING OEXISTING <1> EXISTING OEXISTING OEXISTING < EXISTING O7 EXISTING OEXISTING GRASS 'O9 PROPOSED VERIZON WIRELESS U.C. POWER/TELCO ROUTE (APPROX. 30't) DIRT ACCESS ROAD 0.H. POWER LINES (TYPICAL) UTILITY POLE (#1339373) (VERIZON WIRELESS P.O.C.) BOLLARD (TYPICAL) FIRE HYDRANT SINGLE FAMILY RESIDENCE BRUSH LINE AREA (TYPICAL) GENERAL NOTES THIS 15 NOT A SITE SURVEY: ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH AND STREET HALF -WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL MAP AND ARE APPROXIMATE. DIG NOTE: CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 1-800-424-5555 POWER/TELCO NOTE: POWER TO ORIGINATE FROM THE EXISTING UTILITY POLE (#1339373), THEN ROUTE U.G. TO THE PROPOSED METER/DISCONNCET, LOCATED ON THE VERIZON WIRELESS PROPOSED UTILITY RACK. (APPROX. 30'-0"t) TELCO TO ORIGINATE FROM THE EXISTING UTILITY POLE (#1339373), THEN ROUTE U.G. TO TO THE PROPOSED TELCO BOX, LOCATED ON THE PROPOSED VERIZON WIRELESS UTILITY RACK. (APPROX. 30'-0"t) GENERAL NOTES: REFER TO T-1 & 2/A-5 FOR GENERAL NOTES. 1X11 say PLANS PREPARED FOR: � verlZ jlwireless PLANS PREPARED BY: RIM MN I • IF Ili ill II I NI u . I KDC ARCHRECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNW000, WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 S R I LICENSURE: 5773 REGISTERED ARCHITECT 0 DO. ." ° ATE OF WASHINGT I N DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 X 12.-0" DBL WIDE ACCESS GATE ENLARGED SITE PLAN ANTENNA / COAX SCHEDULE SECTOR QUANTITY TIP HEIGHT ANT. SIZE AZIMUTH MBOF C�EAX RU COAX SIZE OAX LENGTH 1 NEW 50.-0" 4'-0" 335' 2 NEW 7/8" 75.-0"t 3 NEW 50.-O" 8'-O" 335' 4 NEW 7/8" 75.-0"t 1 NEW 50'-0" 4'-0" 125' 2 NEW 7/8" 65.-0"t "B" 3 NEW 50'-0" 8'-0" 125' 4 NEW 7/8" 65'-0"t "G" 1 NEW 50.-0" 4'-0" 230' 2 NEW 7/8" 70'-0"t 3 NEW 50.-0" 8'-0" 230' 4 NEW 7/8" 70'-0" t J 10' 20•-0' CHAIN LINK FENCE W/ PRIVACY SLATS/ AREA SCALE FOR 2436: 1/4"= 1'-0" SCALE FOR 11X17: 1/8" = 1'-0" GiG � i L i a_ w,a�'wwWI Di( 6'0 15`��cwe k (egiirc` tcw S l ' of 0 4' 8' 2' 6' NORT H GENEt�AL NOTES `' THIS IS NOT A SITE SURVEY: ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH AND STREET HALF -WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL MAP AND ARE APPROXIMATE. DIG NOTF• CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 1-800-424-5555 FOWFR/TFI CO NOTF. POWER TO ORIGINATE FROM THE EXISTING UTILITY POLE (#1339373), THEN ROUTE U.G. TO THE PROPOSED METER/DISCONNCET, LOCATED ON THE VERIZON WIRELESS PROPOSED UTILITY RACK. (APPROX. 30'-O"t) TELCO TO ORIGINATE FROM THE EXISTING UTILITY POLE (#1339373), THEN ROUTE U.G. TO TO THE PROPOSED TELCO 80X, LOCATED ON THE PROPOSED VERIZON WIRELESS UTILITY RACK. (APPROX. 30'-0"t) GENERAL NOTES: REFER TO T-1 & 2/A-5 FOR GENERAL NOTES. FENCE NOTES: REFER TO 6/A-5 FOR FENCE NOTES. SCALE FOR 24x36: 1/4"= 1'-0" SCALE FOR 11X17: 1/8" = 1'-0" KEYED.NOTES A OEXISTING ACCESS GATE (TYPICAL) O EXISTING UTILITY RACK O3 EXISTING ICE BRIDGE OEXISTING OUTDOOR EQUIPMENT CABINET OF OTHERS MOUNTED ON I -BEAMS ON CONC. PAD O EXISTING CHAIN LINK FENCE W/ PRIVACY SLATS O EXISTING RELOCATED 3'-6" ACCESS GATE OEXISTING 131'-8"t TALL TRANSMISSION TOWER OB EXISTING 3'-6" ACCESS GATE TO BE RELOCATED EXISTING GRASS AREA <> PROPOSED VERIZON WIRELESS 12'-0' DEL. WIDE ACCESS GATE <> PROPOSED VERIZON WIRELESS UTILTY RACK W/ NEW 200A SERVICE METER. DISCONNECT. TELCO BOX, ILC AND GENERATOR PLUG PROPOSED VERIZON WIRELESS U.G. POWER/TELCO ROUTE (SEE A-1.1 FOR CONTINUATION) PROPOSED VERIZON WIRELESS 6'-O' HIGH CHAIN LINE FENCE W/ PRIVACY SLATS PROPOSED VERIZON PROPOSED VERIZON PROPOSED VERIZON 12 14 15 16 17 18 19 POST PROPOSED VERIZON WIRELESS OUTDOOR EQUIPMENT CABINETS 3 \ (6 TOTAL) MOUNTED ON A 8'-0- X 20'-0" CONC. PAD q PROPOSED VERIZON WIRELESS ANTENNAS (12 TOTAL, 4 PER SECTOR) PROPOSED VERIZON WIRELESS ANTENNA FRAME MOUNT (2 TOTAL) VERIZON WIRELESS COAX ROUTE AT TRANSMISSION TORE' PROPOSED <> PROPOSED VERIZON WIRELESS 2-3/6' X 12'-6' STIFF ARMS TO CONNECT TO TOWER LEG (MAX 1'-6' FROM TOWER BRACING JOINTS: TYPICAL) PROPOSED VERIZON WIRELESS ADJUSTABLE SLOPE MOUNT (3 TOTAL) Q3 PROPOSED VERIZON WIRELESS SECTOR FRAME MOUNT NORTH WIRELESS COAX ROUTE AT ICEBRIDGE WIRELESS 10.-0" ICEBRIDGE 5 WIRELESS GPS ANTENNA MOUNT D AT ICEBRIDGE e 'irk'220404 PLANS PREPARED FOR: CO ^^C O\ ^' ftr . i ?0>> NillE kr II Ilia PLANS PREPARED BY: MIK M NI II s. II I 1111 II 111 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SURE 200 LYNNWOOD, WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 I 1 I I LICENSURE: 5773 REGISTERED AIHI CT KENNETH D. CAMP STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION A10 PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 T.O. EXISTING ANTENNAS �OF OTHERS & TRANSMISSION TOWER 125'-6"3 EXISTING SOT. OF ARM altEXISTING BOT. OF ARM EXISTING BOT. OF ARM T.O. PROPOSED VERIZON WIRELESS ANTENNAS 50'-0- floGRADE • O 41> 4'1 r44 Oi�Ol.IIINICI � it iIl11 • • • II_ O d O Ijl�� NORTH ELEVATION SCALE FOR 24x36: 1/8"= 1'-0" SCALE FOR 11%17: 1/16" = 1'-0" 0 8' 16' 4' 12' GRADE T.O. EXISTING ANTENNAS hOF OTHERS & TRANSMISSION TOWER 125'-6°± EXISTING BOT. OF ARM EXISTING VIFBOT. OF ARM EXISTING BOT. OF ARM O • 4> • /4 T.0. PROPOSED VERIZON WIRELESS ANTENNAS 50'-0" GRADE O ICI • i� 0 EAST ELEVATION COAX SCALE FOR 24x36: 1/8"= 1'-0" SCALE FOR 11X17: 1/16" = 1'-0" 0 0 GRADE KEYED NOTES O EXISTING FIRE HYDRANT OEXISTING UTILITY POLE (#1339373) (VERIZON WIRELESS P.O.C.) O EXISTING BOLLARD (TYPICAL) O EXISTING UTILITY RACK OS EXISTING ICE BRIDGE O EXISTING OUTDOOR EQUIPMENT CABINET OF OTHERS MOUNTED ON I -BEAMS ON CONC. PAD OEXISTING CHAIN LINK FENCE W/ PRIVACY SLATS O EXISTING 131'-8"± TALL TRANSMISSION TOWER O EXISTING ANTENNAS OF OTHERS (TYPICAL) <> PROPOSED VERIZON WIRELESS UTILITY RACK W/ NEW 200A SERNCE METER, DISCONNECT, TELCO BOX, ILC AND GENERATOR PLUG 11 PROPOSED VERIZON WIRELESS 6'-0" HIGH CHAIN UNE FENCE W/ PRIVACY SLATS • PROPOSED VERIZON WIRELESS 10.-0" ICEBRIDGE <>PROPOSED VERIZON WIRELESS GPS ANTENNA MOUNTED AT ICEBRIDGE POST <C> PROPOSED VERIZON WIRELESS OUTDOOR EOUIPMENT CABINETS (6 TOTAL) MOUNTED ON A 8'-0" X 20'-0" CONC. PAD <> PROPOSED VERIZON WIRELESS ANTENNAS (12 TOTAL, 4 PER SECTOR) 16 PROPOSED VERIZON WIRELESS ANTENNA FRAME MOUNT (3 TOTAL) <> PROPOSED VERIZON WIRELESS 2-3/8" X 12'-6" STIFF ARMS TO CONNECT TO TOWER LEG (MAX 1'-6" FROM TOWER BRACING JOINTS; TYPICAL) APR A' \ GENERAL NOTES FENCE NOTE; EXISTING AND PROPOSED CHAIN UNK FENCE SHOWN AS DASHED LINE FOR CLARITY. PAINT NOTE: ANTENNAS AND CABLES TO BE PAINTED TO MATCH COLOR OF TOWER. PU1 a()E1 Q I PLANS PREPARED FOR: verlmnwireless PLANS PREPARED BY: mow wow p.m ow Mill MI Ili II In 111 II III NI II I •1 1 1 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SURE 200 LYNNWOOD, WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 1 I I 1 LICENSURE: 5773 KENNETH STATE OF REGISTERED AHI T D. CAMP WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION ,1PM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 T.O. EXISTING ANTENNAS %i0F OTHERS & TRANSMISSION TOWER 125-6" ± EXISTING BOT. OF ARM os!friiEXISTING BOT. OF ARM EXISTING BOT. OF ARM T.O. PROPOSED 4VERIZON WIRELESS ANTENNAS 50 GRADE 400 le0 444 ktA 444 kt4$4 flits I� " •• SOUTH ELEVATION 'SCALE FOR 24x36: I/8"= 1'-0" SCALE FOR 11X17: 1/16" = 1'-0"I 0 0 0 0 8' 16' 4' 12' T.O. EXISTING ANTENNAS 4OF OTHERS & TRANSMISSION TOWER 125'-6"± EXISTING BOT. OF ARM EXISTING BOT. OF ARM AOLEXISTNG BOT kilrOF ARM T.O. PROPOSED VERIZON RELESS ANTENNAS 5WI0•-0" GRADE GRADE WEST ELEVATION SCALE FOR 24x36: 1/8"= 1'-0" SCALE FOR 11X17: 1/16" = 1'-0" KEYED NOTES 10 11 12 13 15 16 EXISTING FIRE HYDRANT EXISTING UTILITY POLE (#1339373) (VERIZON WIRELESS EXISTING BOLLARD (TYPICAL) EXISTING UTILITY RACK EXISTING ICE BRIDGE EXISTING OUTDOOR EQUIPMENT CABINET OF OTHERS MOUNTED ON I -BEAMS ON CONC. PAD EXISTING CHAIN LINK FENCE W/ PRIVACY SLATS EXISTING 131'-8"± TALL TRANSMISSION TOWER EXISTING ANTENNAS OF OTHERS (TYPICAL) PROPOSED VERIZON WIRELESS UTILITY RACK W/ NEW 200A SERVICE METER. DISCONNECT, TELCO BOX. ILC AND GENERATOR PLUG PROPOSED VERIZON WIRELESS 6'-0" HIGH CHAIN UNE FENCE W/ PRIVACY SLATS PROPOSED VERIZON WIRELESS 10.-0" ICEBRIDGE PROPOSED VERIZON WIRELESS GPS ANTENNA MOUNTED AT ICEBRIDGE POST PROPOSED VERIZON WIRELESS OUTDOOR EQUIPMENT CABINETS (6 TOTAL) MOUNTED ON A 8'-0" X 20'-0" CONC. PAD PROPOSED VERIZON WIRELESS ANTENNAS (12 TOTAL, 4 PER SECTOR) PROPOSED VERIZON WIRELESS ANTENNA FRAME MOUNT (3 TOTAL) PROPOSED VERIZON WIRELESS COAX ROUTE AT TRANSMISSION TOWER <2> PROPOSED VERIZON WIRELESS 2-3/8" X 12"-6" STIFF ARMS TO CONNECT TO TOWER LEG (MAX 1'-6" FROM TOWER BRACING JOINTS; TYPICAL) GENERAL>NOTES FENCE NOTE; EXISTING AND PROPOSED CHAIN LINK FENCE SHOWN AS DASHED LINE FOR CLARITY. GRADE 0 8' 16' 4' 12' 171•Ai PLANS PREPARED FOR: vedNftwireless PLANS PREPARED BY: igiIIR pmmg Pal INC R MIMIN NI IN IR• u s ME II 1 •11 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD, WA 98036 PHONE: 425.670.8651 FAX: 425.712.0846 I I I LICENSURE: 5773 I7 KENNETH STATE REGISTERED A I T D. CAMP OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION ,IPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ— PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A 3 1 4.10" 23.520" 1.620" 0 0 ♦ EMERSON +24VDC POWER CABINET • 26.76" 32.00" NOTE: SEE DETAIL 5/A-4 FOR ANCHOR DETAIL .875"0 MOUNTING HOLES IN INTERNAL CABINET FRAME (TYP OF 6 PLACES) 9/16"0 x 1 1/4" SLOTTED HOLES (TYPICAL) EQUIPMENT ATTACHMENT TO SKID PER MFR. SPECS MODCELL 4.08 • 4 5/16" 2'-2 3/4" 4 5/il6" 2'-11 3/8" OUTDOOR EQUIPMENT CABINET DIMENSION & WEIGHT CABINET PRIMARY BATTERY APPROX. MAX. WEIGHT 1497 LBS (679.03 KG) 976 LBS (442.70 KG) DIMENSIONS 35.4"x40"x72" (900mm x 1016mm x 1829mm) 29"x32%85.58" (737mm x 813mm x 2174mm) 35.80" MODCELL CABINET MOUNTING SKID 90'-0" CONCRETE PAD ..- 1„ 2'-8" 9" 2,-8" , 2.-11" 2'-11" 2 -11" 2'-11" 1.- CABINET CABINET CABINET CABINET CABINET CABINET 41 � r z u PROPOSE °i t i PROPOSEG EQUIP. ;ABINET EQUIP. CABINS PROPOSECAROPOSECPROPOSE EQUIP. EQUIP. EQUIP. ROPOSEC EQUIP. CABINET CABINET CABINET "1 CABINET -1 , N M L_J`Lf ` � � J\ ` �\ ___I� \ 1" PROPOSED VERIZON WIRELESS OUTDOOR EQUIPMENT CABINETS (6 TOTAL) PROPOSED 8'-0" X 20.-0" CONCRETE PAO CABINET MOUNTING DETAIL NOT TO SCALE 1/2"0 HARDWARE CABINET CONNECTION TO SKID PER MFR. SPECIFICATIONS (TYP) ANCHOR AT CONC. TO BE 1/2"0 HILTI KWIK BOLT 3, MIN. 3 1/2" EMBED PROPOSED EQUIPMENT CONCRETE PAD ANCHOR DETAIL NOT TO SCALE NOT USED NOT TO SCALE 20'-0" 0 FINAL GRADE SLOPE AWAY FROM CONCRETE PLAN VIEW 20.-0" COMPACTED CRUSHED STONE OR GRAVEL (OPTIONAL; THICKNESS AS REO'D) #5® 12" 0.C. EA. WAY CE OF SLAB FI FVATION VIEW EXCAVATE AS REQUIRED TO REMOVE VEGETATION & TOPSOIL, EXPOSE UNDISTURBED NATURAL SUBGRADE & PLACE CRUSHED STONE AS REQUIRED NOTES• 1. FOR CONCRETE NOTES SEE DETAIL 3/A-5;FOR CIVIL NOTES SEE DETAIL 4/A-5. 2. GRAVEL SHALL BE NATURAL OR CRUSHED STONE WITH 100 PERCENT PASSING 1 INCH SIEVE. CONCRETE PAD DETAIL NOT TO SCALE NOT USED NOT TO SCALE EQUIPMENT LAYOUT NOT TO SCALE PROPOSED VERIZON WIRELESS OUTDOOR EQUIPMENT h1111 CABINETS (6 TOTAL) 1 'I . • I I .I PROPOSED 8'-0" X 20'-0" CONCRETE PAD r. ®EQUIPMENT ELEVATION NOT TO SCALE vi PROPOSED EQUIPMENT CABINET Ei] P/T ENTRY POINTS DETAILS RUBBER BOOT (LUCENT PROVIDED) 1/2" COAXIAL ANTENNA JUMPER CABLES (LUCENT PROVIDED) 2" LIQUID -TIGHT STEEL FLEXIBLE CONDUIT 2" LIQUID -TIGHT CONNECTOR (ASSEMBLY) 2" HUB/COUPLING(PART OF CABINET) 2" LIQUID -TIGHT CONNECTOR (ASSEMBLY) 2" LIQUID -TIGHT STEEL FLEXIBLE CONDUIT PROPOSED 8'-0" X 20'-0" CONCRETE PAD NOT TO SCALE f"45 "d PROSE OUOPTDOORD VERIZONEQUIPMENT4 WIRELESS qP CABINETS (6 TOTAL) 1, Z1! E Eo } ( ( () { l --- co -. — — r-.. ^n 2 0"0"0 pp i pp 9 0"0"0" b 9 O O O O , GRADE I \\\\ ` PROPOSED 8'-0" X 20'-0" CONCRETE PAD O ELEVATION •EQUIPMENT NOT TO SCALE PROPOSED VERIZON WIRELESS OUTDOOR EQUIPMENT CABINETS (6 TOTAL) . IT p lo • I GRADE I \ PROPOSED 8'-0" X 20.-0"4 CONCRETE PAD ELEVATION elEQUIPMENT NOT TO SCALE 1E--LES,1, PROPOSED VERIZON WIRELESS OUTDOOR EQUIPMENT CABINETS (6 TOTAL) PROPOSED 8'-0" X 20.-0" CONCRETE PAD GRADF NOT TO SCALE PLANS PREPARED FOR: Vert'. MnWireless PLANS PREPARED BY: maw *air Pat Milli PM III (III I. . III II III III II I KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD. WA98036 PHONE: 425.670.8651 FAX: 425.712.0846 I I I I LICENSURE: 5773 REGISTERED C CT KENNETH D. CAMP STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUK,WILA, WA 98178 A 4 NOTES: 1. INSERT SCISSOR BRACKETS BETWEEN THE UPPER ANTENNA MOUNTING BRACKET AND THE UPPER POLE ADAPTER BRACKET. SECURE USING 1/2 INCH HARDWARE PROVIDED. 2. TO SET THE DEGREE OF DOWNTILT, ALIGN THE DESIRED HOLES ON THE SCISSOR BRACKETS AND SECURE USING 5/16 INCH HARDWARE PROVIDED. THE NUMBER OF CONNECTORS WILL VARY BASED ON ANTENNA TYPE. OPTIONAL DOWNTILT BRACKET PIPE MOUNT (TYP) VALMONT MICROFLECT PART #81001 OR APPROVED EQUAL PANEL ANTENNA (TYP) PARTS: ITEM QTY DESCRIPTION Q 1 ADAPTER, POLE, LOWER 0 1 BRACKET, DOWNTILT, POLE 0 1 BRACKET, DOWNTILT, ANTENNA 0 6 1/2 X 1 HEX HEAD BOLT © 6 1/2 SPLIT WASHER 0 2 5/16 X 1 HEX HEAD BOLT 0 2 5/16 SPLIT WASHER 0 4 1/2" THREADED ROD 0 8 1/2" SPLIT WASHER ( 12 1/2" NUT GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, REGULATIONS AND SAFETY REGULATIONS, ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANIES' REGULATIONS AND DIRECTIVES. 2. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO REPRESENTATIVE. ANY MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. 3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. 4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA. COAX & ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.C.I. 301, A.C.I. 318 AND THE SPECIFICATION CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, ALL CAST -IN -PLACE CONCRETE SHALL BE NORMAL WEIGHT, AIR -ENTRAINED CONCRETE WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 POUNDS PER SQUARE INCH AT 28 DAYS. TYPE I-11 PORTLAND CEMENT WILL BE USED WITH A MAXIMUM AGGREGATE SIZE OF 3/4" AND 6% ±1% AIR ENTRAINMENT. ALL CONCRETE WILL HAVE A MAXIMUM WATER/CEMENT (W/C) RATIO OF 0.48. 3. ALL CONCRETE FLATWORK SHALL HAVE A STIFF BROOM FINISH AND HAVE A SLOPE OF 1/8" PER FOOT UNLESS NOTED OTHERWISE. 4. REINFORCING BARS SHALL BE NEW BILLET STEEL CONFORMING TO AS.T.M. A615, GRADE 60, DEFORMED. 5. DETAIL, FABRICATE AND ERECT REINFORCEMENT BARS, INCLUDING BAR SUPPORTS, SPACERS, ETC. IN ACCORDANCE WITH "DETAILING OF CONCRETE REINFORCEMENT" (A.C.I. 315-80, REV. 1986). 6. UNLESS OTHERWISE NOTED, ALL LAP SPLICES SHALL BE CLASS B CONFORMING TO ACI 318-95. 7. A CHAMFER OF 1" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE IN ACCORDANCE WITH A.C.I. 301 SECTION 4.2.4 UNLESS OTHERWISE NOTED. 8. CONCRETE WORK SHALL BE COORDINATED WITH THE MECHANICAL, EQUIPMENT, AND ELECTRICAL WORK TO ASSURE THAT ALL AFFECTED PIPES. CONDUITS INSERTS. ETC. ARE IN PLACE AND VERIFIED BEFORE PLACING CONCRETE. 9. CONCRETE COVER FOR REINFORCING BARS SHALL CONFORM TO THE FOLLOWING UNLESS INDICATED OTHERWISE ON THE DRAWINGS: -CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND - 2 INCHES -CONCRETE CAST AGAINST EARTH- 3 INCHES 10.COORDINATE LOCATION OF STEEL ANCHOR BOLTS WITH STEEL FABRICATOR PRIOR TO INSTALLATION IN FIELD. 11.CONTRACTOR SHALL PROVIDE SLEEVES FOR ALL WALL/SLAB PENETRATIONS (PIPING, CONDUIT,ETC.; POWER, TELCO AND COAX TO ENTER SITE UNDER EQUIPMENT SLAB. SEE STUB -UP PLAN ANTENNA MOUNTING DETAIL NOT TO SCALE VALMONT MICROFLECT UNIVERSAL PIPE ADAPTER KIT PART NO. B1534 EXISTING ICE BRIDGE POST OR SIMILAR POST. ELEVATION NOTES. GPS ANTENNA 1 1/4" NOMINAL DIAMETER (1.66" ACTUAL 0.D.) X 2'-0" MAX. SCHEDULE 40 GALVANIZED STEEL MOUNTING PIPE (SEE NOTE 4) COAX CABLE 1. LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25% OF THE SURFACE AREA OF A HEMISPHERE AROUND THE GPS ANTENNA. 2. ALL GPS ANTENNA LOCATIONS MUST BF ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) SATELUTES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCATION OF GPS ANTENNA. 3. THE WEIGHT OF THE ANTENNA MOUNT IS 6.5 LBS. 4. IF ICE BRIDGE OR SIMILAR POST IS NOT GROUNDED, GROUND WITH #2 AWG TINNED BARE COPPER WIRE EXOTHERMICALLY BONDED TO POST AND CONNECTED TO GROUND RING. GPS ANTENNA DETAIL NOT TO SCALE GENERAL NOTES NOT TO SCALE NOTES (INSTALL FENCING PER ASTM F-567, SWING GATES PER ASTM F- 900) 1. GATE POST, CORNER, END OR PULL POST 4" NOMINAL (4.5" 0.0.) SCHEDULE 40 PIPE 5.79 LBS/LIN FOOT FOR GATE WIDTHS UP THRU 6 FEET OR 12 FEET FOR DOUBLE SWING GATE PER ASTM-F1083. 2. LINE POST: 2-1/2" (2.875" O.D.) SCHEDULE 40 PIPE, 3.65 LBS/LIN FOOT PER ASTM-F1083. 3. GATE FRAME: 1 1/2 " (1.875" OD) PIPE, 2.72 LBS/LIN FOOT PER ASTM-F1083. 4. TOP RAIL & BRACE RAIL: 1 1/2 " (1.875" OD) PIPE, 2.72 LBS/LIN FOOT PER ASTM-F1083. 5. FABRIC: 12 GA CORE WIRE SIZE 2" MESH, CONFORMING TO ASTM-A392. 6. TIE WIRE: MINIMUM 11 GA GALVANIZED STEEL AT POSTS AND RAILS A SINGLE WRAP OF FABRIC TIE AND AT TENSION WIRE BY HOG RINGS SPACED MAX 24" INTERVALS. 7. TENSION WIRE: 7 GA. GALVANIZED STEEL. 8. BARBED WIRE: DOUBLE STRAND 12-1/2" 0.D. TWISTED WIRE TO MATCH WITH FABRIC 14 GA, 4 PT. BARBS SPACED ON APPROXIMATELY 5" CENTERS. 9. GATE LATCH: 1- 3/8 " 0.D. PLUNGER ROD W/ MUSHROOM TYPE CATCH AND LOCK, KEYED ALIKE FOR ALL SITES IN A GIVEN MTA. 10. LOCAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENT SHALL BE COMPLIED IF REQUIRED. 11. HEIGHT = 6' VERTICAL + 1' BARBED WIRE VERTICAL DIMENSION. 12. INSTALL VINYL SLATS. CONCRETE NOTES NOT TO SCALE GATE LATCH W/ LOCK BRACE RAIL Lz Ji 41 NOTE: SEE NOTES ON DETAIL 6. GATE POST 12.-0" MIN CATE POST 4" NOMINAL GATE POST (TYP.) FENCE NOTES NOT TO SCALE 10'-0" OC MAX 3 STRANDS BARBED WIRE BOTTOM TENSION WIRE J ICI I ! 11L'.�C ii'I II =1 91`_ TYPICAL ELEVATION NOTE: SEE NOTES ON DETAIL 6. TOP RAIL LINE POST 2 1/2" OD STD PIPE TYPICAL SECTION EXTENSION ARMS TOP OF FABRIC PLANT OR FACILITY SIDE PROJECT ABOVE GROUND AND SLOPE ALL AROUND (TYP) FIN GRADE AS SHOWN DBL. WIDE ACCESS GATE DETAIL NOT TO SCALE CORNER, END OR PULL POST (4" NOMINAL SCH. 40 PIPE) U.N.O. STRETCHER BAR NOTE: SEE NOTES ON DETAIL 6. DIAGONAL ROD W/ TURNBUCKLE (TYP.) BRACE RAIL CHAIN LINK FENCE DETAIL NOT TO SCALE CHAIN LINK FENCE CORNER DEATAIL NOT TO SCALE 1.ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND STIPULATED IN THE SPECIFICATION PROJECT SUMMARY. 2. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 3. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE EQUIPMENT, TOWER AREAS, AND ADJACENT BUILDINGS. 4. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN ' MATERIALS. SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 5. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM Apt) GRADE PRIOR TO THE CRUSHED STONE APPLICATION. �+ cob SUBGRADE AND BASE PREPARATION: O 1Jp/I7 7� 1.FOR SLAB -ON -GRADE CONSTRUCTION IT WILL BE NECESSARY TO OVEREXCAVATE THE SITC�c'p BY 2'-0" AND IMPORT AN APPROVED GRANULAR FILL. THE FILL SHALL BE COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY UNIT WEIGHT WITH A MOISTURE CONTENT WITHIN 2% OF THE OPTIMUM MOISTURE CONTENT AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D-1557).COMPACTION REQUIREMENTS APPLY TO BACKFILL FOR UTILITY TRENCHES AND FOUNDATION EXCAVATIONS WITHIN STRUCTURES, DRIVEWAYS, OR PARKING LOT AREAS. 2. COMPACTION SHALL BE ACCOMPLISHED BY PLACING THE FILL IN SUCCESSIVE, HORIZONTAL, APPROXIMATELY SIX- TO EIGHT -INCH LOOSE LIFTS AND MECHANICALLY COMPACTING EACH LIFT TO AT LEAST THE SPECIFIED MINIMUM DRY DENSITY. 3.ANY ORGANIC MATERIAL, DELETERIOUS MATERIAL, OR DISTURBED SOIL SHALL BE REMOVED FROM FLATWORK AREAS. 4.THE GROUND SURFACE SURROUNDING EXTERIOR STRUCTURES SHALL BE SLOPED TO DRAIN AWAY IN ALL DIRECTIONS. CIVIL NOTES NOT TO SCALE 12" NOTES' CUT POST LENGTH TO SUIT BY REMOVING UNCAPPED END 12" WIDE ICE BRIDGE CUT ICE BRIDGE CHANNEL LENGTH TO SUIT (SEE NOTES) TRAPEZE KIT (2) TRAPEZE KITS ARE INCLUDED WITH ICE BRIDGE. ORDER ADDITIONAL TRAPEZE KITS AS REQUIRED, TO MAINTAIN MAXIMUM CABLE SPAN OF 3'-0" (TYP) ANTENNA CABLES ARRANGEMENT BY CONTRACTOR CONCRETE PIER . INSTALL DRIP LOOP ON ANTENNA CABLES AT BOTTOM OF TOWER/MONOPOLE. BENDING RADIUS PER MANUFACTURER'S STANDARDS 1. WHEN USING COMPONENTS AS SHOWN IN STANDARD DETAILS, MAXIMUM ALLOWABLE SPAN BETWEEN SUPPORTS ON A CONTINUOUS SINGLE SECTION OF BRIDGE CHANNEL SHALL BE 9 FEET FOR 10 FEET BRIDGE CHANNEL. 2. WHEN USING COMPONENTS FOR SPLICING BRIDGE CHANNEL SECTIONS, THE SPLICE SHOULD BE PROVIDED AT THE SUPPORT, IF POSSIBLE, OR AT A MAXIMUM OF 2 FEET FROM THE SUPPORT. 3. WHEN USING COMPONENTS, SUPPORT SHOULD BE PROVIDED AS CLOSE AS POSSIBLE TO THE ENDS OF ICE BRIDGES, WITH A MAXIMUM CANTILEVER DISTANCE OF 2 FEET FROM THE SUPPORT TO THE FREE END OF THE ICE BRIDGE. 4. CUT BRIDGE CHANNEL SECTIONS SHALL HAVE RAW EDGES TREATED WITH A MATERIAL TO RESTORE THESE EDGES TO THE ORIGINAL CHANNEL, OR EQUIVALENT, FINISH. 5. ICE BRIDGES MAY BE CONSTRUCTED WITH COMPONENTS FROM OTHER MANUFACTURERS, PROVIDED THE MANUFACTURER'S INSTALLATION GUIDELINES ARE FOLLOWED. 6. DEVIATIONS FROM STANDARDS FOR COMPONENT INSTALLATIONS ARE PE" IT THE RESPECTIVE MANUFACTURER'S APPROVAL. 7. D• IA `Ai�c ICE B' AGE/OUNDATING APPR IMP B' DETAIL NO TO SCALE PLANS PREPARED FOR: Zre 1\ . r d� %ate Ver 7Qnwireless PLANS PREPARED BY: ImmR mmr, pow P P 1411 III P[ II NE II I 1 1 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD, WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 I F E I LICENSURE: 5773 RAEGISTERED 1 CH CT KENNETH D. CAMP STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A TIE WRAP CABLES TO FORM CLUSTER ATTACH CLUSTER TO INSIDE OF TOWER LEG WITH TIE WRAP 0 TIE WRAP CABLES TO FORM CLUSTER MICROFLECT 82250 AT 11'-0" 0.C. VERTICALY UP INSIDE OF TOWER LEG JOINT (NODE) OF LATTICE TOWER, TYP. ATTACH CLUSTER TO INSIDE OF TOWER LEG WITH TIE WRAP CO 4'-0" 0.C. CLAMP BACK HALF 1/2"0x12" BOLT WITH 6" THREDS (TYP OF 2) 1/2"0 A 563 GR. A HEX NUT WITH LOCK WASHER(TYP OF 2) JOINT (NODE) OF LATTICE TOWER, TYP. MICROFLECT B2250 AT 11'-0" 0.C. VERTICALY UP INSIDE OF TOWER LEG PARTS LIST B2250 DESIG MARK DESCRIPTION QTY 104576 CLAMP BACK HALF 1 - 104577 PLATE WELD ASSY. 1 LT5 1/20 X 12 BOLT W/ 6" THREADS 2 N5 1 1/20 A563 GR. A HEX NUT 2 LW5 1/20 LOCK WASHER 2 TOTAL WEIGHT = 9# EXISTING TOWER FACE TOWER #B 21/0 S EXISTING TOWER LEG II (12) 3/4"0 HOLES FOR SNAP -IN HANGERS (10) 7/16"0 HOLES FOR CUSHION OR BUTTERFLY HANGERS COAX CONNECTOR KIT MICROFLECT B2250 COAX WITH SNAP IN HANGER (TYP) 0 0 0 `WELDED PLATE ASSEMBLY WITH (12) 3/4"0 HOLES FOR SNAP IN HANGERS SECTION A -A ATTACH COAX TO TOWER LEG WITH TIE WRAP AT MAX. 4'-0" 0.C. BIND COAX WITH TIE WRAP AT MAX. 4'-0" 0.C. (6) COAX ROUTE SECTION B-B COAX AT TOWER LEG DETAIL NOT TO SCALE UNIVERSAL ANTENNA MOUNT AT TOWER LEG; REFER TO DETAIL 2/A-6 SITE PRO 1 SECTOR FRAME STIFF ARM KIT, 2-3/8" X 12'-6" (P/N: STK-U). KIT ATTACHES W/ SITE PRO 1 UNIVERSAL STIFF ARM ATTACHMENT (P/N: SAM-U) ANTENNA MOUNTING FRAME ANTENNA MOUNTING PIPE NDIE: DETAIL SHOWN FOR VALMONT/SITEPRO1 PART /EUSF10-2U AND IS SUBJECT TO CHANCE. CONTRACTOR TO VERIFY PARTS PRIOR TO CONSTRUCTION. PARTS LIST MARK DESCRIPTION QTY 27270 ANGLE 8 27685 ANGLE 1 27686 ANGLE 1 27687 PLATE 1 27688 PIPE WELDMENT 1 27689 PLATE WELDMENT 1 TOWER LEG 27686 27685 SUPPORT TO BE MOUNTED 1'-6" MAX. FROM AN EXISTING TOWER JOINT s 0 M HARDWARE LIST SYM QTY DESCRIPTION J7 4 5/80 X 1 3/4 G5 BOLT, NUT & L.W. J8 4 5/80 X 2 G5 BOLT, NUT & L.W. J26 1 5/80 X 6 1/2 G5 BOLT, NUT & L.W. LW5 16 5/80 LOCK WASHER LW7 2 7/80 LOCK WASHER NT5 16 5/80 A563 GR. A HEX NUT NT7 2 7/80 A563 GR. A HEX NUT zuu 1 7/80 X 18 THREADED ROD mv4 8 5/80 X 14 THREADED ROD TOTAL CALV WEIGHT: 170# VERTICAL TO LEG SLOPE RANGE TYP. 8 PLACES TYP. 8 PLACES ELEVATION 4 1/2 0.D. X 60" 27689 SUPPORT TO BE MOUNTED 1'-6" MAX. FROM AN EXISTING TOWER JOINT USE THIS LOCATION FOR 41/2 X 41/2 TO X 6 ANGLE LEGS OR PIPE LEGS FROM 6 5/8 0D TO 8 5/8 OD 2- USE THIS LOCATION FOR 21/2 X 21/2 TO 4 X4 ANGLE LEGS OR PIPE LEGS FROM 2 OD TO 5 9/16 OD TYP. 8 PLACES 27686 PLAN VIEW PLAN VIEW LW7 2-3/8" 0.D. X 72" MOUNTING PIPE VALMONT MICROFLECT PIPE TO PIPE MOUNT PART #92509 4-1/2" 0.D. X 60" MOUNTING PIPE VALMONT MICROFLECT PIPE TO PIPE MOUNT PART #B2512 2-7/8" 0.D. X 60" CROSS -ARM ANTENNA MOUNT DETAIL NOT TO SCALE ANTENNA MOUNT DETAIL NOT TO SCALE NOT USED NOT TO SCALE NOT USED NOT TO SCALE NOT USED NOT TO SCALE PLANS PREPARED FOR:r v ^J CO C J ' 4: 7.04^.,* ...`� zit. ..NI 1011), ow ram` PLANS PREPARED BY: maw 1o110! PIP. IRE MNME 11111 • II 11111 • s I R II u I Mil KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD, WA98036 PHONE: 425.670.8651 FAX 425.712.0846 A f I I LICENSURE: 5773 STATE REGISTED ARCHI ECERT NETH D. C OF WASHINGTO DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 A 6 A 225 A BUS 240 / 120 VOLT, 1 PHASE, 3 WIRE 10000 AMPERE PANEL SHORT CIRCUIT RATING PANEL TYPE: SQUARE D PANEL MOUNTING: SURFACE NOTE: NEMA JR ENCLOSURE DESCRIPTION TOTAL BREAKER CCT PH CCT BREAKER TOTAL DESCRIPTION / P P (VA) RECTIFIER 2000 30 1 A 2 30 / SURGE ARRESTOR 2000 / 2 3 B 4 0 / 2 RECTIFIER 2000 30 / 5 A 6 30 / 2880 AC UNIT 2000 / 2 7 8 8 / 2 2880 RECTIFIER 2000 30 / 9 A 10 / 180 CFCI RECEPTACLE 2000 / 2 11 8 12 / SPACE RECTIFIER 2000 30 / 13 A 14 / SPACE 2000 / 2 15 B 16 / SPACE RECTIFIER 2000 30 / 17 A 18 / SPACE 2000 / 2 19 8 20 20 / 1 SPARE RECTIFIER 2000 30 / 21 A 22 20 / 1 SPARE 2000 / 2 23 B 24 20 / 1 SPARE PANEL LOADING SUMMARY LOAD TYPE CONNECTED POWER LOAD NEC CALCULATED LOAD FACTOR KVA FACTOR LOAD LIGHTING INCANDESCENT 0.0 KW 0 100% = 0.0 0 100"R = 0.0 KVA FLUORESCENT 0.0 KW 0 95% = 0.0 0 100"X = 0.0 KVA RECEPTACLES FIRST 10 KW 0.2 KW 0 100% = 0.2 0 I00-R = 0.2 KVA REMAINDER 0.0 KW 0 100% = 0.0 0 50% = 0.0 KVA MOTORS LARGEST 4.6 KW 0 80% = 5.8 0 125"R = 7.2 KVA REMAINDER 0.0 KW 0 80% = 0.0 0 100"X = 0.0 KVA OTHER 28.2 KW 0 100% = 28.2 0 100-% = 28.2 KVA TOTAL 33.0 KW 34.1 KVA 35.6 KVA MINIMUM PANEL AMPACITY = 148 AMPERES PHASE "A" 16.0 KW PANEL A-B 94% PHASE PHASE "8" 17.0 KW POWER BALANCE FACTOR 97% O (3 A3/0) 2"C C (3 j)3/0 & 1#6G) 2" C 0 (3 #3/0 & 1/j6G) 2" C PROVIDED WITH PANEL "A" ® 1 b4CU - 3/4"C. ALL CONDUCTORS SHALL BE COPPER COPPER 600V. RATED WITH THHN INSULATION MOUNT TO EXISTING UTILITY POLE WITH TRANSFORMER NEW UTILITY METER WITH MAIN BREAKER MOUNTED TO NEW UTILITY RACK r- I L ELECTRICAL NOTES 1. INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE OF WASHINGTON LAWS, RULES AND REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.E.A. S651-401, I.C.E.A. P81-570, & LOCAL PUD. 2. PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK BOARD. 3. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE RGS, (OR PVC ENCASED IN 8"x18" RED CONCRETE DUCTBANK). 4. CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. 5. WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. PROVIDE HDPE PULLING HAND HOLES AS NEEDED. 6. CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE -LUG COMPRESSION TYPE. ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS "NO-OXY", "NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL. 7. ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS LPS-3 OR AS PER NOTE 6 ABOVE. 8. ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH BOX. 9. CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL TVSS. 10. CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES. WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. CONTACT ALL UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. 11. VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED EQUIPMENT SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING OF AIC TO ACCEPTABLE LEVELS. 12. UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. 13. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS REQUIREMENTS AND CONSTRUCT 70 UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. 14. ELECTRICAL DETAILS AND PLANS SHALL BE REVIEWED BY SEATTLE CITY LIGHT ELECTRICAL ENGINEERING. 1 NEMA 3R 200A2P I ENCLOSURE -•NI --.--• G 1 •J 1#48J WP 200A MCB 'PANL� MANUAL A INTERLOCK GENERATOR RECEPTACLF� " PROVIDED WITH PANEL A PANELBOARD WITH INTEGRATED MANUAL TRANSFER SWITCH PROVIDED BY VERIZON WIRELESS ELECTR:iCALLEGEND \1:1713- L J UNDERGROUND RACEWAY FUSED DISCONNECT TRANSFORMER FEEDER KEY GROUND - - - GROUND CONDUCTOR 1.11 PANELBOARD z FUSED DISCONNECT LOCAL DISCONNECT GROUND ROD PANELBOARD ■ EXOTHERMIC WELD CI METER -1 ELECTRICAL EQUIPMENT L-__-J ENCLOSURE ELECTRICAL SERVICE WEATHERHEAD • COMPRESSION TYPE CONNECTION CI TEST WELL I • -1 AUTOMATIC I TRANSFER SWITCH L __J TELEPHONE SERVICE © STAND-BY WEATHERHEAD GENERATOR ®G RECEPTACLENERATORE ABBREVIATIONS AWG AMERICAN WIRE GAUGE BCW BARE COPPER WIRE DWG DRAWING EMT ELECTRICAL METALLIC TUBING GEN GENERATOR IGR INTERIOR GROUND RING (HALO) IMC INTERMEDIATE METALLIC CONDUIT MGB MASTER GROUND BAR PCS PERSONAL COMMUNICATION SYSTEM RGS RIGID GALVANIZED STEEL RWY RACEWAY TYP TYPICAL GRADE GRC ELLS J TYPICAL NEW 120/240V, 10, 3W UNDERGROUND SERVICE d-3/4"x10'-0" LONG DRIVEN GROUND ROD AND TO GROUND RING ONE -LINE DIAGRAM NOT TO SCALE '4 PLANS PREPARED FOR: rCO^ (v)J 6e" ^ W iill li PLANS PREPARED BY: C - INK IF. MIX PM MI II IIF MN 111 11 1 • • ii i KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD, WA 98036 PHONE: 425.670.8651 FAX 425.712.0846 1 1 I LICENSURE: 5773 REGISTE .I RC KENNETH D. CAMP STATE OF WASHINGTON D DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD .4/20 2011 ISSUED FOR REVISED CONSTRUCTION AIO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 PLANS PREPARED FOR: - - PROPERTY LINE 148_90't - - -OH APN: 687420-1170 -01+ 5.08 -OH- ELECTRICAL SITE PLAN SCALE FOR 24x36: 1"= 20.-0" SCALE FOR 11X17: 1" = 40'-0" 0 I I 0 e1 0 0 1 O 20' 40' 10' 30' NORTH PROPERTY LINE 0+1 KEYED NOTES 1 EXISTING DIRT ACCESS ROAD 2 EXISTING 0.H. POWER LINES (TYPICAL) OEXISTING UTILITY POLE (#1339373) (VERIZON WIRELESS P.O.C.) OEXISTING BOLLARD (TYPICAL) OEXISTING FIRE HYDRANT OEXISTING SINGLE FAMILY RESIDENT OEXISTING BRUSH LINE O8 EXISTING GRASS AREA OPROPOSED VERIZON WIRELESS U.G. POWER/TELCO ROUTE (APPROX. 30't) a <> PROPOSED VERIZON WIRELESS UTILITY RACK W/ NEW 200A SERVICE METER DISCONNECT, TELCO BOX, ILC AND GENERATOR PLUG 4p4 ink TAIT GENERAL NOTES THIS IS NOT A SITE SURVEY: ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH AND STREET HALF -WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL MAP AND ARE APPROXIMATE. DIG NOTE; CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 1-800-424-5555 POWER/TEI CO NOTF: POWER TO ORIGINATE FROM THE EXISTING UTILITY POLE (#1339373), THEN ROUTE U.C. TO THE PROPOSED METER/DISCONNCET, LOCATED ON THE VERIZON WIRELESS PROPOSED UTILITY RACK. (APPROX. 30'-00"t) TELCO TO ORIGINATE FROM THE EXISTING UTILITY POLE (#1339373), THEN ROUTE U.G. TO TO THE PROPOSED TELCO BOX, LOCATED ON THE PROPOSED VERIZON WIRELESS UTILITY RACK. (APPROX. 30'-00"t) GENERAL NOTES: REFER TO T-1 & 2/A-5 FOR GENERAL NOTES. SFATTI F CITY I IGHT NOTE: ELECTRICAL DETAILS AND PLANS SHALL BE REVIEWED BY SEATTLE CITY LIGHT ELECTRICAL ENGINEERING. 11X.Ai PLANS PREPARED BY: — MI NW IF 1 II I u u 1 I MO ui I I KDC ARCHITECTS.ENGINEERS, P.C. 4720 2000H STREET SW SUITE 200 LYNNWOOD, WA 98036 PHONE: 425.670.8651 FAX: 425.712.0846 LICENSURE: 5773 REGISTERED RCr11yECT KENNETH D. CAM ESTATE OF WASHINGT N DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION A10 PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 E2 GROUNDING @ EQUIPMENT ELECTRICAL GROUNDING PLANS D SCALE FOR 2406: 1/4"= 1'-0" SCALE FOR 11%17: 1/8" = 1'-0" GENERAL GROUNDING NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). 5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) HIGH PRESS CRIMPS. 6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. 7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 8. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS OTHERWISE INDICATED. 9. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8"0 10-FT. LONG, AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. 10. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. 11. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST LINE. 13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM EQUIPMENT CONCRETE PAD, SPREAD FOOTING, OR FENCE. 14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. 15. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING 16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) 17. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. 18. ELECTRICAL DETAILS AND PLANS SHALL BE REVIEWED BY SEATTLE CITY LIGHT ELECTRICAL ENGINEERING. 19. CONTRACTOR TO VERIFY CURRENT VERIZON WIRELESS GROUNDING STANDARDS PRIOR TO CONSTRUCTION. NORTH <> GROUND TEST WELL (MIN. OF 2 PLACES) O2 #2 AWG BTCW GROUND RING, TYP. O GROUND ROD SPACING 0 10'-0" 0.C. MIN. 15'-0" 0.0 O EXISTING TRANSMISSION TOWER GROUND RING O CONNECT AGB TO MGB WITH (2) #2 BTC O EXISTING MGB 0 BASE OF TRANSMISSION TOWER O7 CONNECT ICE BRIDGE TO GROUND RING, (TYP ALL ICEBRIDGE POST) O MASTER GROUND BUS BAR PROVIDED BY EQUIPMENT MANUFACTURER •C> CONNECT PROPOSED SERVICE UTILITY RACK AS PER N.E.C. CODE .<> CONNECT MASTER GROUND BUS BAR PROVIDED BY EQUIPMENT MANUFACTURER TOI PROPOSED GROUND RING WITH (2) #2 BTCW <2> CONNECT FENCE POSTS TO PROPOSED GROUND RING WITH (2) #2 BTCW <C> CONNECT PROPOSED ANTENNA WITH #2 BTCW TO AGB (TYPICAL AT EACH ANTENNA) <> NEW AGB 0 ANTENNAS TYPICAL GROUNDING @ ANTENNAS CONNECT GPS ANTENNA TO GROUND RING CONNECT FROM EXISTING MGB TO TRANSMISSION TOWER GROUND RING (2 PLACES MIN.) CONNECT GATE SWING TO PROPOSED GROUND RING WITH (2) #2 BTCW (TYPICAL AT EACH POST) PLANS PREPARED FOR: a w,r verinpwireless PLANS PREPARED BY: 111111111W6 IWWW PAW PW INN NI III III II IIII In II II Ili II u 1 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STREET SW SUITE 200 LYNNWOOD. WA 98036 PHONE: 425.670.8651 FAX: 425.712.0846 R I I LICENSURE: 5773 REGISTERED P fj CT KENNETH D. CAMP STATE OF WASHINGTON DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION A10 PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178 LEGEND 1- COPPER GROUND BAR%. "X 4"X 20", NEWTON INSTRUMENT CO. CAT. NO. 8-6142 OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) 2- INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061-4 OR EQUAL 3- 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUAL 4- WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR EQUAL 5- 5/8-11 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 OR EQUAL 6- INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE. CONNECTION TO TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. GRADE #2 SOLID TINNED CU EXTERNAL BUILDING BURIED GROUND RING EXOTHERMICALLY WELD TO GROUND ROD (TYPICAL) GROUND ROD (TYPICAL) 2'-6" MIN. OR 6" BELOW FROSTLINE CADWELD V/NNY/.0 GRADE EXTERIOR GROUND RING #2 AWG. BCW GROUND ROD COPPERWELO 5/8" 0 x 10.-0" LONG FINISHED GRADE OR AC PAVING MATCH SLOPE & THICKNESS OF EXISTING COMPACTED BACKFILL TO MIN 95% MODIFIED MAX. DENSITY PER ASTM D1557 METHOD D UNDISTURBED EARTH 4"0 TELEPHONE CONDUIT EDGE TO EDGE d„ APR CO, 0EV0 UTILITY WARNING TAPE 2"0 POWER CONDUIT BACKFILL (SAND OR NATIVE SOIL) TYPICAL GROUND BAR DETAIL NOT TO SCALE PVC COLLAR 8" MAX. TO TOP OF TEST LEAD 1 30" 1MAX. L EXOTHERMIC WELD (THERMOWELD OR EQUIVALENT) DIRECTLY TO TOP OF GROUND ROD MALE SCREW COVER. INSTALL WITH TEFLON LUBRICANT — FINISHED GRADE 2"MAX. SUBGRADE 8" x 42" DIA. PVC WITH FEMALE ADAPTER & SCREW ON CAP #MT-C6492 #2 SOLID, BARE, TINNED COPPER GROUNDING CONDUCTOR #2 SOLID, BARE, TINNED COPPER GROUND RING 1---Sx 1O' COPPER CLAD STEEL GROUND ROD 1" WIDE SLOT. TYPICAL FOR 2. EXTEND 2" ABOVE GROUND RING (8" TYPICAL) EXTERIOR GROUND RING DETAIL NOT TO SCALE NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.) TO ANTENNAS JUMPER REQUIRED ONLY FOR 1 5/8"0 COAX OR FOR EASE OF CONNECTION (TYP.) CONNECTOR WEATHERPROOFING KIT (TYP.) SEE NOTE 2 RXO Y Y TXO #2 AWG STRANDED INSULATED BONDED TO TOWER STEEL OR MONOPOLE RX1 ��� WEATHERPROOFING JKIT (TYP.) STANDARD GROUND KIT (TYP.) (SEE NOTE) ANTENNA CABLE TO SHELTER (TYP.) �—ANTENNA GROUND AWG BAR, SIMILAR TO K16-057. MOUNT GROUND BAR NEAR TOP OF MONOPOLE, TOWER OR WAVECUIDE LADDER. GROUND ROD DETAIL NOT TO SCALE ANTENNA CABLE WEATHERPROOFING KIT (SEE NOTE 3) 12" TO 24" CABLE GROUND KIT #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) 2 1/2"0 MAX. CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE NOTES' 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO -HOLE LUG. 3, WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. POWER/TELEPHONE TRENCH DETAIL NOT TO SCALE STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. SIZE AS SPECIFIED GROUND BAR ON WALL, FLOOR OR ON ANTENNA TOWER O O O • GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. ♦ O / TWO -HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1/4"STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE. .TWO -HOLE LUG, TO BE USED WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION TO ANTENNA STRUCTURE, BUILDING RING GROUND OR MGB GROUND TEST WELL NOT TO SCALE NOT USED NOT TO SCALE ANTENNA GROUND BAR NOT TO SCALE NOT USED NOT TO SCALE CABLE GROUNDING DETAIL NOT TO SCALE NOTE: ELECTRICAL DETAILS AND PLANS SHALL BE REVIEWED BY SEATTLE CITY LIGHT ELECTRICAL ENGINEERING. SEATTLE CITY LIGHT NOTE NOT TO SCALE GROUND BAR CONNECTION NOT TO SCALE P1000 UNISTRUT (TYP) NEW 4" 0 GALV. STD PIPE x 10'-0" 200A METER BASE W/ DISCONNECT PLACE AS REQ. 9_ P1000 UNISTRUT (TYP) ILC W/ GEN• PLUG 200A METER BASE W/ DISCONNECT NEW0 GALV. STDD PIPE x 10' -0" FINISHED GRADE TELCO BOX ILC WITH GEN. PLUG 12"000x NC. 4'-O" •.�DEEP FTG. T RAC NOT TO SCALE 2 PLANS PREPARED FOR: ry \---- VerlZgnwireless PLANS PREPARED BY: 88614IR mow 0! IR F NMMI I IF I lilt Ill III Ill ION II I Ill • III1 KDC ARCHITECTS.ENGINEERS, P.C. 4720 200TH STOEET SW SURE 200 LYNNWOOD, WA 98036 PHONE: 425,670.6651 FAX 425.712.0846 I I 1 LICENSURE: 5773 RT ARCHITECTEGISERED N T STATE OF . WASHINGTO DATE: 04/20/2011 DRAWN BY: RLD CHECKED BY: EJC REVISIONS DATE DESCRIPTION BY 11/17 2010 ISSUED FOR 90% CD REVIEW RLD 12/02 2010 ISSUED FOR CONSTRUCTION BAH 12/21 2010 ISSUED FOR REVISED CONSTRUCTION JPM 01/19 2011 ISSUED FOR REVISED CONSTRUCTION BAH 01/31 2011 ISSUED FOR REVISED CONSTRUCTION RLD 04/20 2011 ISSUED FOR REVISED CONSTRUCTION MO PROJECT: SEAQ- PONCHO S. 109TH & BEACON AVE S. TUKWILA, WA 98178