HomeMy WebLinkAboutPermit S11-029 - CONTINENTAL MILLS - MONUMENT SIGNCONTINENTAL MILLS
18000 ANDOVER PARK W
S11-029
1 MONUMENT SIGN
Parcel No.:
Address:
Suite No:
City oftukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.ci.tukwila.wa.us
3523049018
18000 ANDOVER PK W TUKW
MONUMENT SIGN PERMIT
Commerical/Industrial Zones
Applicant/Business: CONTINENTAL MILLS
Permit Number:
Issue Date:
Permit Expires On:
S11-029
04/06/2011
10/03/2011
Property Owner:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Contact Person:
Name: STEVE ZAMBERLIN
Address: 1255 WESTLAKE AVE N , SEATTLE WA 98109
Contractor:
Name: NATIONAL SIGN CORPORATION
Address: 1255 WESTLAKE AVE N , SEATTLE 98109-3531
Phone: 206-282-07000
Phone: 206 282-0700
DESCRIPTION OF WORK:
ONE FREESTANDING MONUMENT SIGN: "CONTINENTAL MILLS HOME OF KRUSTEAZ AND OTHER FINE BRANDS"
Fees Collected: $212.00 Zoning: HI
Name of street frontage:
Total sign area per face:
Total sign area per sign:
Total sign size per face:
Total sign size per sign:
Width of sign:
Height of sign:
Distance from closest edge
of sign to property lines:
Name of street frontage:
Total sign area per face:
Total sign area per sign:
Total sign size per face:
Total sign size per sign:
Width of sign:
Height of sign:
Distance from closest edge
of sign to property lines:
Monument # 1
ANDOVER PARK W
43 square feet
43 square feet
575 square feet
575 square feet
11 feet 6 inches
5 feet 0 inches
10 feet
Monument #4
0 square feet
0 square feet
0 square feet
0 square feet
0 feet 0 inches
0 feet 0 inches
0 feet
Monument #2
0 square feet
0 square feet
0 square feet
0 square feet
0 feet 0 inches
0 feet 0 inches
0 feet
Monument #5
0 square feet
0 square feet
0 square feet
0 square feet
0 feet 0 inches
0 feet 0 inches
0 feet
Sign Type:
Monument #3
0 square feet
0 square feet
0 square feet
0 square feet
0 feet 0 inches
0 feet 0 inches
0 feet
Monument #6
0 square feet
0 square feet
0 square feet
0 square feet
0 feet 0 inches
0 feet 0 inches
0 feet
***continued on next page***
doe: SIGN-MON
S11-029 Printed: 04-06-2011
Planning Division Authorized Signature:
Date 1//
I hereby certify that I have read and ex 'fled this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510
for sign final inspection. Please allow up to 5 business days for your inspection.
FINAL INSPECTION APPROVAL: DATE:
***continued on next page***
doc: SIGN-MON
S11-029 Printed: 04-06-2011
File No.
Name of Tenant:
Sign Address:
Date Photo Taken:
SITE INSPECTION (PLANNING)
S11-029
Continental Mills
18000 Andover Pk W
6/21/2011
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
Comments: Sign inspected and final approval granted. JMW 06-23-2011
CITY OF TUKWILA. ECEIVED PERMANENT
Department of Community eve opntettt FREESTANDING
6300 Southcenter Boulevard, Tukw'1p� 'A 8� 8n
Telephone: (206) 431-3670 FAX (( . 3 3 5 LU I I SIGNS
E-mail: tukplan@ci.tukwilama.usCOMUMTY
DEVEL
NT
PERMANENT SIGN PERMIT APPLICATION
FOR STAFF USE ONLY Permits Plus Type: P-SIFREE
Planner.
Needs Electrical: Yes
ilch',I/gm:h94J
File Number. e b
Associated File Num ers: 1/
coivfldrtifft
Business Name
51 of zsmitraciti
Applicant/Contact
'soot) 1 VpoV0pt p C z f
Address of Sign
Z"G- ?/6- ago
Phone
p✓4aigrt 514,1 cay. uj 412- 070,
Address, City, State, Zip
Phone
NA11a✓At Sim COO 4VV. ,✓. sEMfi ' *$ tot - tt 2-O7v o
Contractor Address, City, State, Zip
Phone
1 HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. 1
understand that if 1 provide incorrect informa .n o this application or submit plans that are not correct, it could delay issuance
of a permit or, if the permit has been issued, .e c.jse or the City to revoke the sign permit.
7- 30-1,
Date:
Signat a o' t mer or Authorized Agent
stlevergnipl roiv, %S,jn cep. (Doi
Email
The City will send any official notices, letters, .nd other official notices via email. if you wish to receive all official
communications from the City via US Postal Mail, check here: ; I
CHECKLIST
O Three copies of completed and signed application
form (this form).
O Three copies of a dimensioned and scaled site plan
showing property lines, streets, buildings and
parking areas; the location of all existing
freestanding signs on the premise and proposed
location for any new freestanding sign(s).
O Method of illumination. if proposed.
O Scaled and dimensioned footing designs and height
calculations. Footing designs are not required for
reface or copy changes to an existing freestanding
sign, provided there is no change in the sign
height, area or location.
O Structural calculations if the sign has an area
greater than 50 square feet and/or is taller than 15
feet. This requirement may be waived for certain
refaces or copy changes to existing freestanding
signs.
O Application fee listed in current fee schedule.
O One copy of a valid Washington State Contractor's
license or owner's affidavit.
O Tukwila business license number for he sign
contractor, if applicable: 0' °l a V j 7
TOTAL NUMBER OF SIGNS
Total number of signs included in this application:
Section 1
Section 3
Section 2
Section 4
General Information about Property
Total Length of Street Frontage Along All Streets:
C7I.`fJ /
,- y,
An c -vt' f P4 t k IA/
Does the site front on more than one street, but have
less than 800 feet of linear frontage, combined on
both streets?
/ n
Jl 1 / !A
Is the site use a multi family or institutional use in a
residential zone (LDR, MDR, or HDR)?
f�//
r
Freestanding Sign Worksheet
A sign permit is required for the installation of a new freestanding sign. In most circumstances the City only allows new
freestanding signs to be monument style signs. Certain large premises that have gone through the Master Sign Program are
eligible for grand monument signs. Information on installing a new freestanding sign is found in SECTION 1 of this
application. Information on installing new grand monument signs can be found in SECTION 2 of this application.
A sign permit is also required for any proposed reface or copy change to an existing freestanding sign in the City. In some
cases a reface or copy change of an existing freestanding sign requires that the sign be removed. Information on completing a
reface or doing a copy change to an existing freestanding sign can be found under SECTION 3 of this application.
Section 1- New Freestanding Signs
Freestanding Signs in Commercial/industrial Zones
Each premise is permitted to have one freestanding -monument style sign. Additional monument signs are permitted based on
the total amount of linear street frontage along the premise. Table 1 below outlines the development standards and total number
of signs permitted for most premises. •
Total
ROW of
Premise
Allowable Sign
Message Areal
Total Allowable
Sign Size2
Maximum
Height
Number of Signs
Less than
400 feet
36 square feet per
side/72 square feet total
r.
54 square feet per
side/108 square feet
total
6 feet
One
400-599
feet
50 square feet per
side/100 square feet
total
70 square feet per
side/140 square feet
total
7 feet
One
600-799
feet
60 square feet per
side/120 square feet
total
80 square feet per
side/160 square feet
total
7 feet
One
800-999
feet
66 square feet per
side/132 square feet
total
88 square feet per
side/176 square feet
total
8 feet
Two
1,000 feet
and over
72 square feet per
side/144 square feet
total
96 square feet per
side/192 square feet
total
8 feet
One for every 400 feet of
linear street frontage.
Corner Properties
Some corner properties may qualify for more than one monument sign, even if they have a limited amount of street frontage. A
property that borders on more than one public street, but has less than 800 total feet of linear frontage, is permitted to have one
monument sign per street if the following criteria are met:
1. The property has a least 200 feet of frontage on each public street where a sign will be placed;
2. Each public street provides direct access to the property; and
3. For each separate street frontage Table 1 listed above shall be used to determine the design standards for any proposed
monument sign.
General Requirements for Monument Signs in Commercial and Industrial Zones
1. Setback. All monument signs shall be placed at a minimum of five feet from all property lines; however no sign taller
than three feet shall be placed within the sight distance triangle, unless it can be demonstrated the sign will not pose a
safety risk by reducing visibility for motorists turning out into traffic.
2. Maximum Width. The maximum width permitted for any new monument sign is 15 feet,
3. Address Requirement. All new freestanding signs shall have the address number or address range of the premise
listed on the structure. The address shall not be counted toward the allowable sign message area limit. Address
numbers niust be plainly legible and visible from the street fronting the property. The address numbers must contrast
with the sign background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a
minimum of four inches high with a minimum stroke width of 1.5 inches.
The allowable message area is either the face pane of the sign, or for channel letters or signs painted on seating or retaining walls, that portion of the sign devoted to
the actual message , logo, or business name.
Total size is the entire area of the sign, including the support structure.
Table 1, Monument Sign Details, Commercial/Industrial Zones
Monument
Sign 1
Monument
Sign 2
Monument
Sign 3
Monument
Sign 4
Monument
Sign 5
Monument
Sign 6
Name of Street
on which sign
will be placed?
1/Deir t
A., I,j �,/
rim% Irv(
Total Sign
message area
per face.
it3 ,fr
113 i
oal Sign
message area
per sign.
Totaper f cSegn Size
per face
�� ,f�
�1
Total Sign Size
per sign.
0 t'
Width of Sign
if
Sign Height
(feet -inches)
ii
Distance from
closest edge of
sign to
property lines
(in feet)
! it
to -o
Freestanding Signs in Residential Zones
Institutional uses and multi -family complexes are allowed to have one monument sign for each public street that provides
access to the premises. The following are the specific development standards that apply to the installation of monument signs in
residential zones:
1. The area of the monument sign is limited to 30 square feet per sign face and a total of 60 square feet for all sides:
2. The sign may be up to five feet tall;
3. Maximum width of the sign shall not exceed 15 feet;
4. Location of the sign shall not interfere with sight distance of vehicles pulling in and out of the premises;
5. The sign must be located in a landscaped area. Having the sign stand-alone in a parking lot is not permitted; and
6. The sign may only use indirect lighting methods except for dynamic displays. The lighting must have no spill -over
impact on adjacent properties.
Dynamic Signs in Residential Zones
In order to foster civic community outreach and communication, the City permits limited use of dynamic signs within
residential zones. One permitted monument sign per premise, as outlined above, may contain a dynamic feature. The following
are the specific development standards applicable to the installation of dynamic signs within residential zones:
1. The image of the sign may not change more frequency than once every ten seconds;
2. The image must appear and disappear as one image. The image may not appear to flash, undulate, pulse or portray
explosions, fireworks, flashes of light, or blinking or chasing lights, or appear to move toward or away from the viewer,
expand, contract, bounce, rotate, spin, twist, scroll, travel or otherwise portray movement.
3. Illumination of the dynamic sign is limited to the hours of 7AM to 10PM.
4. All signs shall have installed ambient light monitors, and shall at all times allow such monitors to automatically adjust
the brightness level of the electronic sign based on ambient light conditions. Maximum brightness levels for electronic
signs shall not exceed 3-foot candle above ambient light conditions, measured 100 feet from the face.
Tabe2, Monument Sign Details, Residential Zoncs
Monument
Sign 1
Monument
Sign 2
Monument
Sign 3
Monument
Sign 4
Name of Street
in which sign
will be placed
along?
Total Area of
Sign.
Sign Height
(fcet-inches)
Width of Sign.
Will the sign
have a
Dynamic
Display?
Section 2- Grand Monument Signs
Premises that have an approved Master Sign Program are eligible to install two grand monument signs. A grand monument
sign takes the place of one of the monument signs permitted in section I of this application. The design of the grand monument
sign shall have an architectural treatment that is consistent with the design of the building or buildings on premise in which the
sign will be located.
Before you fill out this section you should first see if the premise you are applying for has an approved Master Sign Program. If
not; your first step is to submit a master sign permit application. The City will not issue a permit for a grand monument sign
until the Master Sign Program is approved by the City.
Table 3, Grand Monument Sign Details
Grand
Monument
Sign 1
Grand
Monument
Sign 2
Reserved for
Staff Use
For more detail see TMC 19.32.060
(B)(2).
Street in which
sign will be
placed along?
.
Each grand monument sign would
substitute for one monument sign
permitted in Table 1 listed above.
Maximum of two grand monument signs
per premise.
Total Sign
Area per face.
Sign message area may be increased up to
100 square feet per side, 200 square feet
total. For sites over 85 acres, the sign
message area may be increased up to 500
square feet per side, 1000 square feet
total.
Total sign area
per sign.
Total Sign Size
per face
No limitation on total structure size.
Total sign size
per sign.
Sign Height
(feet -inches)
Height of the sign structure may not
exceed the height of the tallest building on
the premises, except for sites over 85
acres, the height may exceed the tallest
building but shall not exceed 115 feet.
Height of
Tallest
Structure on
the premise
where the
grand
monument sign
will be
located?
Distance from
closet edge of
sign to
property lines
(in feet)
The sign must be setback from the side
and rear property lines of the premise a
distance equal to the height increase
requested or five feet, whichever is
greater. The minimum front setback is
the smaller of the front yard required in
the zoning district or the height increase
requested.
Section 3- Reface and Co.y Change of Existing Freestanding Signs
When the current sign code became effective on August 24, 2010, the City strived to create a sign code that would reduce the
impact to property owners and businesses that had existing freestanding signs on their property. The city permits refaces and
copy changes to existing freestanding signs under several different scenarios:
I. A freestanding sign that confonns to the current sign code is permitted refaces and copy changes with a permit.
2. A freestanding sign that is not considered a freeway interchange sign, which was legally installed under the previous
sign code but does not meet the current Sign Code, is permitted to have refaces and copy changes for up to TEN years
from the effective date of the City's Sign Code (8/24/10). A permit is required for any reface or copy change. Please
note, modifying the sign height, increasing the sign area, or relocating the sign is not permitted without bringing the
sign into full conformance with the City's Sign Code. At the end of the ten year period the sign may remain as -is
indefinitely, however additional refaces or copy changes will require that the sign be brought into conformance with
the Sign Code.
3. A freestanding sign that is considered a freeway interchange sign and was legally installed under the previous sign
code is permitted to have refaces and copy changes for up to FIVE years from the effective date of the City's Sign
Code (8/24/10). A permit is required for any reface or copy change. Please note, modifying the sign height,
increasing the sign area, or relocating the sign is not permitted. At the end of the five year period the sign may remain
as -is indefinitely, however any changes to the face or structure of the sign will require that the sign be removed.
4. Freestanding signs that did not comply with the City's previous sign code, for example those that were installed while
an area was in King County, are not permitted to have any changes to the face or structure of the sign without bringing
the sign into conformance with the Sign Code.
Staff can help you research previous permit history to determine if your existing freestanding sign was installed under the
provisions of the City's previous Sign Code.
You will note that under Section I of this sign permit application additional signs are allowed for premises with over 800 feet of
linear street frontage or for corner properties. Even if your property qualifies for this additional signage under Section 1 you
will not be able to install it until any existing non -conforming sign(s) are removed (TMC 19.36.070).
Table 4. Existing Freestai ding Sian Details
Existing
Freestanding
Sign 1
Existing
Freestanding
Sign 2
Notes:
Date of last sign
permit issued by the
City for sign that is
being modified:
Existing Sign Area:
Proposed Sign Area:
Sign Height (feet -
inches):
Distance from closet
edge of sign to
property lines (in
feet):
INSPECTIONS
A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to
schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for
scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at
(206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection.
GENERAL
The issuance of some signage within the City may require a permit from the Washington State Department of Transportation
(WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For
information on permits that may be required from WSDOT call (360) 705-7296.
The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions
of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this
code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other
data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC
19.12.020 (C)).
Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The
Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the
180 day period.
Contractors or Tradespeople Prir`-- Friendly Page Page 1 of 1
Electrical Contractor
A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time
supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
Parent Company
NATIONAL SIGN CORPORATION
2062820700
1255 Westlake Ave N
Seattle
WA
981093531
King
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
578048524
Active
NATIOSC031M3
Electrical Contractor
7/23/1997
7/23/2011
Sign
Unused
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
NATIOSC535PZ
NATIONAL SIGN
CORP
Electrical
Contractor
General
Unused
10/9/1947
2/28/1999
Archived
Electrical Administrator INFORMATION
License ZAMBET*974K0
Name ZAMBERLIN, TIMOTHY
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
ZAMBERLIN, TIMOTHY D
01/01/1980
ZAMBERLIN, STEPHEN G
01/01/1980
ZAMBERLIN, GEORGE S
01/01/1980
ZAMBERLIN, TIMOTHY
Agent
01/01/1980
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
CBIC
628632
08/10/1990
Until Cancelled
$4,000.00
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions/Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
ESEA000368
9/2/2010
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00
EJONM00226
3/7/2006
19.28.271 RCW
ELECTRICAL CITATION
Satisfied
$250.00
https://fortress.wa.gov/lni/bbip/Print.aspx 03/30/2011
File: "Continental Mills 10 . 1011
3" Exist Concrete Wall
0
M
11 '-6"
AS*C11 to loess
),1
•
rAl
., Gar` �e O eA vo-g'i1
alanges
/9".
e
rzt
rt3
0
10'-0"
33"
Concept D 1
Single Face Monument Display
Scale: 17' = 1'-O"
J/a,,
RECEIVED
WAP 3 0 Nil \
IWO gem
Sign Face
Secondary Cabinet
Secondary Cabinet Panel
Attachment Frame
"CM" To be Cut Out Of 3/8"
Plate Aluminum. Paint White.
(satin finish) Non -Illuminated. Pin Mount
Flush To Background Panel.
Background Panel: Cut Out Of 3/8"
Aluminum . Paint Dk. Blue.
(satin finish) Non -Illuminated. Pin Mount Flush
To Radius Sign Face.
Primary Sign Face: Fabricated .125 Aluminum Panel
With Radius Top. 3" Return. Paint
Terra Cotta. (satin finish) Non -Illuminated.
Attach Flush To Secondary Cabinet Panel.
Copy: "Continental Mills" With
Underscore: To Be Cut Out Of 3/8"
Brushed Aluminum. Horizontial Grain (clear
satin finish)
Letters Are To Pin Mount Flush to
Sign Face.
Secondary Cabinet Panel: To Be Fabricated
2"Aluminum Angle Frame. Face To Have .125 Sheet
Aluminum Face. Paint Tan. Cabinet Panel
To Mount To Matching Angle Frame On
Concrete Base With Countersunk Screws.
Secondary Face Panel: Fabricated Aluminum.
Face To Be.125 Aluminum Mounted to 2"Aluminum
Square Tube Spacer. Paint Dk. Blue.
All Copy To Be Opaque Vinyl Applied To First
Surface. Attach Flush To Secondary Cabinet
Panel.
1/8"
Top Back Portion Of
Radius Sign Face To
Be Finished.
Bottom Remainder Of
Panel To Be A Shell.
— Concrete Base
(by others)
End View
national sign
1255 Westlake Ave. N.
Seattle, WA 98109
P: (206) 282-0700
F: (206) 285-3091
www.nationalsigncorp.com
This Is An Original Unpublished
Drawing, Created By National Sign
Corporation. It Is Submitted For
Your Personal Use In Connection
With A Project Being Planned For
You By National Sign Corporation.
It 1s Not To Be Shown To Anyone
Outside Your Organization, Or
To Be Used, Reproduced, Copied
Or Exhibited In Any Fashion. Any
Usage Beyond That Granted To
Buyer Herein Shall Require The
Separate Payment Of A Design
And Engineering Fee To National
Sign Corporation.
- File: "Continental Mills • .fh 1011
SUDA?T
•31'1<CL.`• 1�{
1rf(J1
#ii@^y"j0
�OM Oj
EN£Nt!INEliRLS NORTHWEST, TWC., P.S. STatrrtritAL 'NGINu ICS
61164 Vk. t,I µ5N Ay_. N. E—i1245, SF►TTI FF^ A ► A 41I19 t2Otr) 32 --7`tiu FAX (21N)) R 572-E411
PRC/11Cr 4. Pxu:trr OAT, (1`11 L I.Sr S rGA) os u- .2 - 23-
Sfu•!•e Or
41
1-0
12' 72
3'-0"
0,6"
PLAN VIEW
Board form
G 24.50
0' S"
3'44'
BACK ELEVATION
Y. = 1.-0.
5'-0"
CROSS-SECTION
Y. CHAMFER
national sign
1255 Westlake Ave. N.
Seattle, WA 98109
P: (206) 282-0700
F: (206) 285-3091
www.nationalsigncorp.com
This Is An Original Unpublished
Drawing, Created By National Sign
Corporation. It Is Submitted For
Your Personal Use In Connection
With A Project Being Planned For
You By National Sign Corporation.
It Is Not To Be Shown To Anyone
Outside Your Organization, Or
To Be Used, Reproduced, Copied
Or Exhibited In Any Fashion. Any
Usage Beyond That Granted To
Buyer Herein Shall Require The
Separate Payment Of A Design
And Engineering Fee To National
Sign Corporation.
File: "Continental Mills r .fh 10tt
z nationall sion
SITE TRIANGLE
_ ggQp CFS IINE
ENE! HIGH WATER)
•
r
r
18100 ANDOVER PARK WEST
2 STORY BUILDING
57,568 S.F. +/—
EL. 30.25
PROPOSED H13M1YEH1 SIGH
Sign Location
SITE PLAN
SCALE. 1' = 30'
0
fo
�m
so
GRAPHtt SrA1 r
2 I.
Lu
SHOE DOA FIGURE p1 30• POLE
r..., DOUBLE SHOE DD>, WOK PI b• POLE
•. BOLLARD 100
-. PATHWAY 100 EN 12•-15• POLE
t
PARTIAL SITE PLAN
s
ti
national sign
1255 Westlake Ave. N.
Seattle, WA 98109
P: (206) 282-0700
F: (206) 285-3091
www.nationalsigncorp.com
This Is An Original Unpublished
Drawing, Created By National Sign
Corporation. It Is Submitted For
Your Personal Use In Connection
With A Project Being Planned For
You By National Sign Corporation.
It Is Not To Be Shown To Anyone
Outside Your Organization, Or
To Be Used, Reproduced, Copied
Or Exhibited In Any Fashion. Any
Usage Beyond That Granted To
Buyer Herein Shall Require The
Separate Payment Of A Design
And Engineering Fee To National
Sign Corporation.