Loading...
HomeMy WebLinkAboutPermit S11-046 - JACK IN THE BOX - BUILDING MOUNTED SIGNJACK IN THE BOX 3742 S 144 ST S11-046 1 BLDG MOUNTED SIGN City of•ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PERMANENT SIGN PERMIT Wall or Awning Face Sign Parcel No.: 1523049295 Permit Number: S11-046 Address: 3742 S 144 ST TUKW Issue Date: 05/23/2011 Suite No: Permit Expires On: 11/19/2011 Business: Property Owner: Name: SEG 56TH LLC Address: 845 106TH AVE NE #100 , BELLEVUE WA 98004 Contact Person: Name: KIRSTEN HANSON Address: 727 S 96 ST , SEATTLE WA 98188 Phone: 206-623-3100 Contractor: Name: HEATH NW INC Phone: 800-613-4559 Address: 727 S 96 ST , SEATTLE WA 98108 DESCRIPTION OF WORK: 2 WALL SIGNS FOR JACK IN THE BOX ELECTRICAL PERMIT FOR THIS SIGN: EL11-0413 NORTH/RIGHT ELEVATION EAST/FRONT ELEVATION (RELATED PERMITS: S11-041, S11-043 Fees Collected: $424.00 Zoning: NCC Sign Type: Electricity Provided by: ?? WALL SIGN: Total exposed building face: Permitted sign area: Area of sign: AWNING FACE SIGN: Area of awning: Sign area: Type of lighting: Type of material of awning: Type of material of sign: INCENTIVE WALL SIGNAGE: Location of Entrance: Total Exposed Building Face: Area of Wall: Method of Lighting: Planning Division Authorized Signature: Wall Sign #1 1584 square feet 67.52 square feet 25.8 square feet Awning Sign #1 0 square feet 0 square feet Wall Sign #2 880 square feet 40.2 square feet 25.8 square feet Awning Sign #2 0 square feet Awning Sign #3 0 square feet Date: I hereby certify that I have read and ex 'fled this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied vfith, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF doc: WALL -AWN S11-046 Printed: 05-23-2011 ISSUANCE, OR IF THE WORK IS SU; WED OR ABANDONED FOR A PERIOD 1 80 DAYS FROM THE LAST INSPECTION. To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. FINAL INSPECTION APPROVAL: DATE: doc: WALL -AWN S11-046 Printed: 05-23-2011 File No. Name of Tenant: Sign Address: Date Photo Taken: SITE INSPECTION (PLANNING) S11-046 Jack in the Box 3 742 S 144th St 7/29/2011 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and final approval granted. JMW 07-15-2011 (05/10/2011) Teri Svedahl Jack in the Box F. as Page 1 Front: Teri Svedahl To: kirstenh©heathnorthwest.com Date: 05/10/2011 3:27 PM Subject: Jack in the Box sign Hi Kirsten, you were just in and submitted on a sign permit for Jack In The Box on S. 144th Street, Tukwila; Sign permit # S11-046. I just noticed the permit was for 2 signs. I only entered 1. When this gets reviewed and is ready for pick up, there will be a balance of $212.00 owing. So sorry I missed that second sign. Thank you, Teri Svedahl Administrative Support Technician City of Tukwila Building and Planning Department 206.431.3670 a St: It „r \'•;nhin:iun DEPARTMENT OF LABOR AND INDUSTRIES PO BOX 44460 OLYMPIA WA 98504-4460 HEATH NW INC 727 S 96TH ST SEATTLE WA 98108 i..,25.(l2-400 F625-O52-0110 i R/V? ) I IKSI-('i..1S'; \;.1I1. d .�. !'+>51.1(;1; 1'11I) I'FR\II I' 4312 DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS < ELEC CONTR SIGN LICENSE # EXP. DATE ECO4 HEATHNI981JZ 4/9/2012 EFFECTIVE DATE 4/9/2002 HEATH NW INC 727 S 96TH ST SEATTLE WA 98108 LICENSED AS PROVIDED ELEC CONTR SIGN LICENSE # ECO4 HEATHNI98IJZ EFFECTIVE DATE HEATH NW INC 727 S 96TH ST SEATTLE WA 98108 BY LAW AS EXP. DATE 4/9/2012 4/9/2002 I- I wt.! h\ Oi• L:\!i( )IZ \Nl) INN 'S I1:11.S Please Remove And Sian Identification Card Before Placing In Billfold Date: CITY OF TUKWILA Department of Community Development 6300 Southcenier Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplan cr ci.tukwila.wa.us PERMANENT BUILDING MOUNTED SIGNS PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-SIBLDG Planner. Needs Electrical: Yes/No File Number: t L—d la Associated File Numbers: S ` ` ^ 6 3p.L.x wry*. box 3142 5.1441% ST. -rv4wiLA Business Name Address of Sign YARSTEN 1'tANSotJ 121 S. °11,0 STD SE;ATrLE Applicant/Contact Address, City, State, Zip )kEA-r NDR.'rimesr `117 S PUP' STt Segraz Contractor Address, City, State, Zip 2010 242•$S'!'1 . V tt. fS‘ti Phone uto1.o23.3ibo Phone 2blolo23.31oo Phone 1 HEREBY CERTIFY that the information contained in this application and the materials fumished to the City by me are true. I understand that WI provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for therevoke the sign permit. 5-1.0 41 " j. jctAwl $►1{tSTEN H-e KG 4fl1 NORT'N .Cat Si a ure of)Owner or A h i . d Agent Email The City will send any official notices, letters, and other official notices via email. If you wish to receive all official cumn:u.tications from the. City via US Postal n4^;1. -'•"1 h. - CHECKLIST • Three copies of completed and signed application form (this form). • Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing building mounted signs on the same building as the proposed signs. • Three copies of scaled and dimensioned drawings of the proposed sign or signs with area calculations. • Three copies of a scaled elevation of the building walls where the signs will be located indicating the location and dimensions of the exposed building face used to calculate the sign area. Fi 'Three copies of a scaled and dimensioned building profile, if projecting signs are proposed. • Method of illumination, if proposed. • Method of support and attachment for building - mounted signs. Structural calculations if the sign weighs over 400 pounds. • Application fee listed in current fee schedule. • One copy of a valid Washington State Contractor's license or owner's affidavit. • Valid Tukwila business license number for the n A q sign contractor, if applicable: eNS, �baq L•I TOTAL NUMBER OF SIGNS Total number of sii%gns included in this application: Section I L.. Section 2 Section 3 C> Section 4 0 Building Mounted Signage Worksheet The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs, see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Section 1- Wall or Awnin: Face Si: Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size' of your wall sign: Maximum Sign Area AREA (Lxl-I) of Exposed Building Face (EBF) in square feet Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF-500) x .04 + 25 square feet 1501-3,000 (El3F-1,500)'x .03+ 65 square feet 3,001-5,000 (EBF-3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet Sign Sign Reserved for Cit} Use For more detail see the Sign -Code Language, TMC 19.20.050 A. Wall Area t J l The size of the sign is based on the area of the 1 -5411a Set) `�W C f ' wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum ^ n 0 75'aVA, Calculate the maximum sign area allowed for Sign Hiv- 1A2 •y 1 µ •!.. tl'_' ?ll '. , tl� ial,lc above. Proposed // Calculate the area by drawing one box around Area of Sign 25 C/t/ / 'the entire sign face or copy using 90 degree !•�+" ZS G : Egles. Sigii Copy ?71h(. . "Me -2-A“.. W*1I + . ii c Di List what the sign will say (for example nameW of business). Awning Face Sign Worksheet Sign Sign Reserved for Citv Use For more detail see the Sign Code Language, TMC 19.20.050 B. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will he located. see TMC 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the %vall from the table above. Area of Awning Face The size of an awning face sign is limited to the area from the table above or 30% ()Idle area of the face of the awning, whichever is smaller. Proposed Area of Sign Calculate the area by drawing one box around the entire sign copy using 90 degree angles. Lighting Type Only indirect lighting maybe used for awning face signs. Awning Material In commercial zones awnings may only be made of canvas or nylon fabric. Sign Material Signs may only be vinyl or paint applied directly to the awning. Sign Copy List what the sign will say (for example name of business). This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was _ranted. Section 2- Incentive Signage- Wall signs may also be installed on walls that do not have public entrances if the wall where the sign will be located meets at least one of the following design criteria: I. At least 50 percent of the wall area between the height of 2 and 7 feet must be transparent with either an unobstructed view into the business or use or a display window with a depth of at least three feet. 2. Architectural detailing consistent with the building design using changes in color, materials, texture, and variations in the wall plane. 3. Artwork such as mosaic, mural or sculptural relief covers at least 50 percent of the wall surface. lithe artwork uses words or images related to the business on site they will be considered part of the sign area. 4. One or more trellises covering at least 50 percent of the wall area between the height of two and seven feet, planted with climbing vines and other plant materials in a planting bed at least two feet in width and provided with permanent irrigation. Signs permitted under this Section may be up to 50 percent of the area calculated in the Table in Section 1. Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 F 4. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the wall from the Table in Section 1 and reduce by half. Proposed Area of Sign Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy List what the sign will say (for example name of business). ,P Q'ec,t. wa- One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and Section 2. In order to qualify fin- a sign under this 'section the business utilizitig the projecting or canopy edge sign must have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The sign is not permitted to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings will qualifvfor a projecting or canopy edge sign. Projecting Sign i' l fr Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 C. Proposed Area of Sign Maximum area permitted is 20 square feet per face and 40 square feet total for all faces. Distance Sign Extends from Building The sign may not stick out more than four feet from the building tall. Also, the sign can't extend further than the sidewalk it overhangs. Height above ground The bottom edge of the sign must be at least eight feet above the sidewalk or walkway that it overhangs. Rotating Display Proposed - Mechanical rotating displays are permitted. Sign Copy List what the sign will say (for example name ofhusiness1. Canopy Edge Sign Is( t7A Canopy edge signs are limited to a single row of individual letters which are not permitted to extend beyond the edge of the canopy on which the sign is located. The canopy must be located over a public entrance. Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 E. Height of letters Maximum height allowed is 12 inches Length of Canopy The sign length is limited to 2/3 of the length of the canopy. Length of Sign Proposed Lighting The letters may be lit, specify whether and how this is proposed. Sign Copy List what the sign will say (for example name of business). Section 4- Pedestrian Oriented Building Mounted Signage In order to encourage a more pedestrian oriented environment, the City allows the following signs in addition to those listed in sections 1, 2 and 3 of this application. Permits are only required for signs listed under this section if the signs will be discernable from any public right of way, a neighboring site or an off -site business. Na all businesses will qualify for signage under this section. Under-Awning/Canopy Signs In order to quality for under-awning/canopy signs an entrance to a business must be provided from a public or private sidewalk. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(l). Number of signs? If located on multiple walls, list wall location. Only one permitted per business per wall. Area of sign? No sign shall exceed three square feet in area. Depth of awning or canopy'? No sign may project farther from the building than its associated awning or canopy. Distance of sign from wall? Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. .ur.Qu.. a• �, c: .. In order to qualify for an awning/canopy side sign, the awning or canopy must be located above a public entrance. Also, the sign is not permitted to project beyond Ole edge of the awning or canopy in which the sign is located on. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(2). Number of signs? If located on multiple walls, list wall location. Only one sign permitted per business per wall. Area of awning or canopy side? Area of sign? Sign may not exceed 40 square feet of awning or canopy side area (Row (in). Height of text and/or graphics? May not exceed a height of 12 inches. Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. If an awning is being used, material of awning? Awning signs may only be nude of yin)! or paint applied directly to the awning. Permanent Window Signs N 1F& Permanent window signs arc only permitted if the following conditions are met: I. The signs will be placed in a ground floor window that provides direct line of sight into the public area of the business. Note: Permanent window signs are not permitted in windows located along private offices, storage space, display windows or windows that are opaque or otherwise do not allow viewing into the business. 2. The placement of the permanent window signs is on the same wall as the public entrance for the business. Permanent Window Signs Applicant's Response Reserved for Use by City Statl'. Applicable Code Language, TMC 19.20.050 (F)(3). Area of window? Total Area of signs? No more than ten percent of the total ground floor transparent window area along the exposed building face of a business may be occupied by permanent window signs. Spandrel, opaque and mirrored glass do not qualify for window signage. No individual sign may he larger than six square feet. In no case shall the total sign area in the window, including both permanent window signs and temporary window signs, exceed 25 percent of the window area. Height of Letters and text? No window sign shall have a height greater than eight inches. Proposed Materials? The signs may be made of gold or silver leaf, vinyl or paint, applied directly to the glass; etched into the glass. neon mounted or suspended behind the glass; or framed and mounted paper signs. Method of illumination? Signs may only utilize neon tubing. INSPECTIONS A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. The issuance of some signa_c . ^ the City may require a .. mit from the Washington State Depa t Tr t _ ,��� .: < rtme^ ..^,f ansoor anon (WSDOT).—it ,t is Elie tip; iic<uti s rosl,uc, iCi it} tci oi0iin tilt req tired jternut: .em tlapp opri ie government agency. for information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not he construed to he a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not he valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. C. SB 07'F 184.27 ' •_ N6952'25'W 00' 520'0730.W 10.00' Har3sorw "WIT — — SOUTH 144TH ST. SITE PLAN SCALE: 1 "=40'-0" KEY B1 B2 EXISTING SIGN: D/F INTERNALLY ILLUMINATED POLL SIGN 8'-0" X 8'-0" CABINET ("JACK INTHE BOX'). REFACE EXISTING CABINET WITH UPDATED LOGO PROPOSED SIGN: S/F INTERNALLY ILLUMINATED WALL SIGN 5'-1" X 5'-1" CABINET ("JACK IN THE BOX'). PROPOSED SIGN: S/F INTERNALLY ILLUMINATED WALL SIGN 5'-1" X 5'-1" CABINET ("JACK IN THE BOX'). 4)14EXISTING SIGN: ' S/F INTERNALLY ILLUMINATED POLL SIGN 5'-0" X 5'-0" CABINET ("JACK IN THE BOX'). REFACE EXISTING CABINET WITH UPDATED LOGO rim SIGNS & GRAPHICS 4530 Mission Gorge Place San Diego, CA 92120 Tel: 619.283.2191 Fax: 619.283.9503 Web: www.cnpsigns.com CLIENT in the box PROJECT JACK IN THE BOX #8365 RE -IMAGE PERMIT PACKAGE LOCATION 3742 S. 144TH STREET TUKWILA, WA 98168 SHEET TITLE SITE PLAN ACCT REP. TRAVIS CROUSER DESIGNER GERALD MCCLUNG DATE SCALE 04/22/11 NOTED CUSTOMER APPROVAL UNLESS SPECIFIED, THIS DRAWING IS NOT FOR PRODUCTION. The information shown is for permitting and design intent only. Colors shown are representations of the indicated specifications, and may not be an exact match of the finished product. ©2010 CNP Signs & Graphics The original concepts and/or illustrations contained in this document/design are The exclusive property of CNP Signs & Graphics. Disclosure or reproduction of this design, in any manner or medium without authorized and written consent of CNP is express ty forbidden. DWG* PROJECT# 11-238 309466 REVISION NO. WO* 0 000000 REVISIONS 1 00/00/00 DESIGNER 7 00/00/00 DESIGNER 2 8 3 9 4 10 5 11 8 12 KEY NO. 1 of 7 1 B1 PROPOSED SIGN: S/F INTERNALLY ILLUMINATED WALL SIGN 5'-1" X 5'-1" CABINET ("JACK IN THE BOX'). r- i L-1 NORTH/RIGHT ELEVATION \‘'L •s 4' the do S V , i I L—J SCALE: 1/8" = 9c, EAST/FRONT ELEVATION AO\VD• 2 B2 PROPOSED SIGN: S/F INTERNALLY ILLUMINATED WALL SIGN 5'-1" X 5'-1" CABINET ("JACK IN THE BOX'). SCALE: 1/8" = a 0 SIGNS & GRAPHICS 4530 Mission Gorge Place San Diego, CA 92120 Tel: 619.283.2191 Fax: 619.283.9503 Web: www.cnpsigns.com CUENT in the box PROJECT JACK IN THE BOX #8365 RE -IMAGE PERMIT PACKAGE LOCATION 3742 S. 144TH STREET TUKWILA, WA 98168 SHEET TITLE ELEVATIONS ACCT. REP. TRAVIS CROUSER DESIGNER GERALD MCCLUNG DATE SCALE 04/22/11 NOTED CUSTOMER APPROVAL UNLESS SPECIFIED, THIS DRAWING IS NOT FOR PRODUCTION. The information shown is for permitting and design intent only. Colors shown are representations of the indicated specifications, and may not be an exact match of the finished product. ©2010 CNP Signs & Graphics The original concepts and/or illustrations contained in this document/design are The exclusive property of CNP Signs & Graphics. Disclosure or reproduction of this design, in any manner or medium without authorized and written consent of CNP is expressly forbidden. DWG; 11-238 PROJECT• 309466 REVISION WO* REVISIONS 1 7 2 8 3 9 4 10 5 11 8 12 KEY NO. 3 of 7 4'-10 3/8" VISIBLE OPENING 5'-1" CABINET 4'-10 3/8" VISIBLE OPENING ELEVATION VIEW 5'-1" X 5'-1" JIB-08 BUILDING SIGN 25.8 SQUARE FEET SCALE: 3/4" = 1'-0" DISCONNECT SWITCH ALUMINUM CABINET WITH INTERNAL FLUORESCENT ILLUMINATION LEXAN FACE WITH EMBOSSED LOGO & COPY BUILDING WALL (THICKNESS & MATERIAL MAY VARY) 1 3/8 "l 41/2" I 61/2" PRIMARY ELECTRICAL 120 V TRANSCO TRA-16-832 EP BALLAST 120V/ 50-60 Hz/ 2.0 AMPS/ 687V OUTPUT SIGN TO BE UL LISTED (W/ DISCONNECT SWITCH AS REQUIRED) SIDE VIEW C3 C4 C5 COLOR SPECIFICATIONS C1 ■Lacryl Series 400 LW-5-9404-1 'JIB Red" Painted second surface C2 ■Lacryl Series 400 443 "Deep Red" Painted second surface Lacryl Series 400 L-403-W "White" Painted second surface 3M 3630-61 "Slate Grey" Vinyl Applied second surface Matthews "Slate Grey" w/ Satin Finish (to match vinyl) EXTRUDED ALUMINUM RETURNS WIREWAY .063 TWO-PIECE ALUMINUM BACK FORMED .118" LEXAN FACE (4) F60 T12/DL/HO/RDC 3/8" LAGBOLTS INTO BLOCKING OR STUD (MIN. 4 PER SIGN); USE PRE -DRILLED ATTACHMENT POINTS @ CORNER KEYS WEEP HOLES 6 1/2" SECTION VIEW SIGNS & GRAPHICS 4530 Mission Gorge Place San Diego, CA 92120 Tel: 619.283.2191 Fax: 619.283.9503 Web: www.cnpsigns.com CLIENT in the box PROJECT JACK IN THE BOX #8365 RE -IMAGE PERMIT PACKAGE LOCATION 3742 S. 144TH STREET TUKWILA, WA 98168 SHEET TITLE WALL SIGN ACCT. REP. TRAVIS CROUSER DESIGNER GERALD MCCLUNG SCALE 04/22/11 NOTED CUSTOMER APPROVAL UNLESS SPECIFIED, THIS DRAWING IS NOT FOR PRODUCTION. The information shown is for permitting and design intent only. Colors shown am representations of the indicated specifications, and may not be an exact match of the finished product. ©2010 CNP Signs & Graphics The original concepts and/or illustrations contained in this document/design are The exclusive property of CNP Signs & Graphics. Disclosure or reproduction of this design, in any manner or medium without authorized and written consent of CNP is expressly forbidden. bWG# 11 238 PROJECT # 309466 REVISION NO. WO# REVISIONS 1 7 2 8 3 9 4 10 5 11 6 12 KEY NO. B1 B2 6 of 7