Loading...
HomeMy WebLinkAboutPermit S12-014 - JACKSON'S SHELL STATION - BUILDING MOUNTED SIGNJACKSONS 13138 INTERURBAN AVE S S12-014 1 BLDG MOUNTED SIGN Parcel No.: Address: Suite No: Business: City of'�kwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PERMANENT SIGN PERMIT Wall or Awning Face Sign 0003000108 13138 INTERURBAN AV S TUKW JACKSONS Permit Number: Issue Date: Permit Expires On: S12-014 04/23/2012 10/20/2012 Property Owner: Name: PACWEST ENERGY LLC Address: 3450 COMMERCIAL CT , MERIDIAN ID 83642 Contact Person: Name: CHRISTEN CARLSON Address: PO BOX 4478 , BOISE ID 83711-4478 Contractor: Name: YESCO Address: 416E 41ST , BOISE, ID 83714 Phone: 208 345-2982 Phone: 208-345-2982 DESCRIPTION OF WORK: INSTALL ONE NEW FLUSH -MOUNTED WALL SIGN FOR JACKSON'S SHELL STATION. Fees Collected: $222.00 Zoning: C/LI Sign Type: LIGHT WALL SIGN: Total exposed building face: Permitted sign area: Area of sign: AWNING FACE SIGN: Area of awning: Sign area: Type of lighting: Type of material of awning: Type of material of sign: INCENTIVE WALL SIGNAGE: Location of Entrance: Total Exposed Building Face: Area of Wall: Method of Lighting: Wall Sign #1 445.5 square feet 22.28 square feet 17.82 square feet Awning Sign #1 0 square feet 0 square feet Wall Sign #2 0 square feet 0 square feet 0 square feet Awning Sign #2 0 square feet Electricity Provided by: SEATTLE CITY Awning Sign #3 0 square feet doc: WALL -AWN S12-014 Printed: 04-23-2012 Planning Division Authorized Signature: Date: Y./()' I hereby certify that I have read and amined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Signature: fi)) Gt Print Name: Date: THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: WALL -AWN S12-014 Printed: 04-23-2012 SITE INSPECTION (PLANNING) File No. S12-014 Name of Tenant: Jackson's Shell Sign Address: 13138 Interurban Ave S Date Photo Taken: 8/20/2012 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and final approval granted. JMW 08-20-2012 Jon Morrison Winters From: Jon Morrison Winters Sent: Thursday, April 19, 2012 3:51 PM To: Christen Carlson (ccarlson@yesco.com) Subject: Sign Permit Application #S12-014 (Jackson's Wall Sign) Dear Sign Permit Applicant, The City of Tukwila Department of Community Development has completed our review of your sign permit application. This will serve as an official notice of decision. Your application has been approved and is available for you to pick up at our office, 6300 Southcenter Blvd, Ste 100. If your sign is illuminated, you may be required to obtain an electrical permit when you pick up your sign permit. The permit is valid for 180 days from the date of issuance. You are required to request a final inspection prior to the permit expiration date or the permit will expire. To request an inspection, please call our inspection line at 206-431- 2451. You may be granted one extension of not more than 30 days if you submit a request for extension prior to permit expiration. Additional Information: Permit S12-013 for the reface of the freestanding sign is still under review. If you prefer to have this permit mailed to you, or if you have any additional questions, please call 206-431-2164 and reference the permit number listed above. Sincerely, Jon Morrison Winters Department of Community Development City of Tukwila Jonathon.winters@tukwilawa.gov 206-431-2164 My office hours for the Spring quarter are 8:00 AM — 4:00 PM Monday and 12:30 PM — 4:30 PM Thursday. Thank you for your patience. 1 DEPARTMENT OF L 'FOR AND INL _ JTRIES F625-052-000 (8/97) LICENSED AS PROVIDED BY LAW AS ELEC CONTR SIGN LICENSE # EXP. DATE ECO4 YESCOL*900LP 6/17/2012 EFFECTIVE DATE 6/17/2010 YESCO LLC 2401 FOOTHILL DR SALT LAKE CITY UT 84109 Detach And Display Certificate LICENSED AS PROVIDED BY LAW AS ELEC CONTR SIGN LICENSE # EXP. DATE ECO4 YESCOL*900LP 6/17/2012 EFFECTIVE DATE 6/17/2010 YESCO LLC 2401 FOOTHILL DR SALT LAKE CITY UT 84109 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES F625-052-000 (8/97) Please Remove And Sign Identification Card Before Placing In Billfold CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us PERMANENT BUILDING MOUNTED SIGNS PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-SIBLDG Planner: File Number: f jij-O I%j Needs Electrical: Yes/No Associated File Numbers: jjj ,�7'r�L�S(j11,5 Business Name Tot P3 Applicant/Contact Yr-.CC) Contractor , I 1jerur r� GL. 5 Address of Sign 01 y1/-o1r3. holV �t. CnmW,F.Cr lI a i icrieLA (O (q tao' ) S - c 1 Address, City, State, Zip Phone lifK .1/1 0 I[ 0;5e 1-0 g 37 j 2/ ( o -) .3.5'-Nc/t Address, City, State, Zip \'Phone r I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if 1 provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for the City to revoke the sign permit. 3/0'l1 (corlfonk'y t Date: f Signature of Owner or Authorized Agent Email L+ The City will send any official notices, letters, and other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ CHECKLIST Completed and signed application (this form). Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing building mounted signs on the same building as the proposed signs. Three copies of scaled and dimensioned drawings of the proposed sign or signs with area calculations. Three copies of a scaled elevation of the building walls where the signs will be located indicating the location and dimensions of the exposed building face used to calculate the sign area. AThree copies of a scaled and dimensioned building profile. if projecting signs are proposed. Method of illumination, if proposed. Method of support and attachment for building - mounted signs. )1/ Structural calculations if the sign weighs over 400 pounds. Application fee listed in current fee schedule. One copy of a valid Washington State Contractor's license or owner's affidavit. Valid Tukwila business license number for the sign contractor, if applicable: 011 337 TOTAL NUMBER OF SIGNS Total number of signs included in this application: Section 1 Section 3 1 Section 2 Section 4 vQlbe apoo Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc r1 RECEIVED r'm' OF TUKIANA APR .02 20121 tlimIT CENTER Building Mounted Signage Worksheet The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs, see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Section 1- Wall or Awning Face Sign Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size' of your wall sign: Maximum Sign Area AREA (LxH) of Exposed Building Face (EBF) in square feet Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF-500) x .04 + 25 square feet 1501-3,000 (EBF-1,500) x .03+ 65 square feet 3,001-5,000 (EBF-3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 A. Wall Area fI i$ S �/ G l The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area )) - az O' the wall from the table above. Calculate the maximum sign area allowed for Proposed Area of Sign l J - ce )` p. Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy nape t7 Fies,RC3 List what the sign will say (for example name of business). Awning Face Sign Worksheet Sign _ Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 B. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see TMC 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the wall from the table above. Area of Awning Face The size of an awning face sign is limited to the area from the table above or 30% of the area of the face of the awning, whichever is smaller. Proposed Area of Sign Calculate the area by drawing one box around the entire sign copy using 90 degree angles. Lighting Type Only indirect lighting maybe used for awning face signs. Awning Material In commercial zones awnings may only be made of canvas or nylon fabric. Sign Material Signs may only be vinyl or paint applied directly to the awning. Sign Copy List what the sign will say (for example name of business). This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc Section 2- Incentive Signage Wall signs may also be installed on walls that do not have public entrances if the wall where the sign will be located meets at least one of the following design criteria: 1. At least 50 percent of the wall area between the height of 2 and 7 feet must be transparent with either an unobstructed view into the business or use or a display window with a depth of at least three feet. 2. Architectural detailing consistent with the building design using changes in color, materials, texture, and variations in the wall plane. 3. Artwork such as mosaic, mural or sculptural relief covers at least 50 percent of the wall surface. If the artwork uses words or images related to the business on site they will be considered part of the sign area. 4. One or more trellises covering at least 50 percent of the wall area between the height of two and seven feet, planted with climbing vines and other plant materials in a planting bed at least two feet in width and provided with permanent irrigation. Signs permitted under this Section may be up to 50 percent of the area calculated in the Table in Section 1. Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 F 4. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the wall from the Table in Section 1 and reduce by half. Proposed Area of Sign Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy List what the sign will say (for example name of business). Section 3- Projecting and Canopy Edge Signs One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and Section 2. In order to qualify for a sign under this section the business utilizing the projecting or canopy edge sign must have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The sign is not permitted to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings will qualify for a projecting or canopy edge sign. Projecting Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 C. Proposed Area of Sign Maximum area permitted is 20 square feet per face and 40 square feet total for all faces. Distance Sign Extends from Building The sign may not stick out more than four feet from the building wall. Also, the sign can't extend further than the sidewalk it overhangs. Height above ground The bottom edge of the sign must be at least eight feet above the sidewalk or walkway that it overhangs. Rotating Display Proposed Mechanical rotating displays are permitted. Sign Copy List what the sign will say (for example name of business). Canopy Edge Sign Canopy edge signs are limited to a single row of individual letters which are not permitted to extend beyond the edge of the canopy on which the sign is located. The canopy must be located over a public entrance. Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 E. Height of letters Maximum height allowed is 12 inches Q:\Department Folders\DCD\DCD Common \Applications -Handouts, Land Use\Building Mounted Sign-May2011.doc Length of Canopy The sign length is limited to 2/3 of the length of the canopy. Length of Sign Proposed Lighting The letters may be lit, specify whether and how this is proposed. Sign Copy List what the sign will say (for example name of business). Section 4- Pedestrian Oriented Building Mounted Signage In order to encourage a more pedestrian oriented environment, the City allows the following signs in addition to those listed in sections 1, 2 and 3 of this application. Permits are only required for signs listed under this section if the signs will be discernable from any public right of way, a neighboring site or an off -site business. Not all businesses will qualify for signage under this section. Under-Awning/Canopy Signs In order to qualify for under-awning/canopy signs an entrance to a business must be provided from a public or private sidewalk. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(1). Number of signs? If located on multiple walls, list wall location. Only one permitted per business per wall. Area of sign? No sign shall exceed three square feet in area. Depth of awning or canopy? No sign may project farther from the building than its associated awning or canopy. Distance of sign from wall? Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. Awning/Canopy Side Sign In order to qualify for an awning/canopy side sign, the awning or canopy must be located above a public entrance. Also, the sign is not permitted to project beyond the edge of the awning or canopy in which the sign is located on. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(2). Number of signs? If located on multiple walls, list wall location. Only one sign permitted per business per wall. Area of awning or canopy side? Area of sign? Sign may not exceed 40 square feet of awning or canopy side area (Row @). Height of text and/or graphics? May not exceed a height of 12 inches. Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. If an awning is being used, material of awning? Awning signs may only be made of vinyl or paint applied directly to the awning. Permanent Window Signs Permanent window signs are only permitted if the following conditions are met: 1. The signs will be placed in a ground floor window that provides direct line of sight into the public area of the business. Note: Permanent window signs are not permitted in windows located along private offices, storage space, display windows or windows that are opaque or otherwise do not allow viewing into the business. 2. The placement of the permanent window signs is on the same wall as the public entrance for the business. Permanent Window Signs Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(3). Area of window? Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc Total Area of signs? No more than ten percent of the total ground floor transparent window area along the exposed building face of a business may be occupied by permanent window signs. Spandrel, opaque and mirrored glass do not qualify for window signage. No individual sign may be larger than six square feet. In no case shall the total sign area in the window, including both permanent window signs and temporary window signs, exceed 25 percent of the window area. Height of Letters and text? No window sign shall have a height greater than eight inches. Proposed Materials? The signs may be made of gold or silver leaf, vinyl or paint, applied directly to the glass; etched into the glass, neon mounted or suspended behind the glass; or framed and mounted paper signs. Method of illumination? Signs may only utilize neon tubing. INSPECTIONS A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. GENERAL The issuance of some signage within the City may require a permit from the Washington State Department of Transportation (WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc 4 Ci@f07-1 ENTRY ELEVATION 3116" = 1 %0" 3" SIGN S ttetf:' " 1L F FACEIBKGD TYPE 3116" CLEAR ACRYLIC VINYL RED 3630-33.2ND SURFACE GREY 3630.61 -2ND SURFACE WHITE DIFFUSER - 3RD SURFACE FACEILETTERS TYPE 'A" CLEAR ACRYLIC VINYL WHITE DIFFUSER - 1ST SURFACE NOTE GLUE PLEX LETTERS TO BKGD 'NOTE!SIGN IS CURREN LY LOCATEO IN E YESCO SEA LE i SHOP DRAWING RELIT. IYE5IN0 ENG. DRAWING REDO. YESIND I ELEC. HOOKUP INCLUDED' YESIND DETAIL AT SIGN 3/8' = as IA lerfa dy ; / UTh YESCO. Boise Division 416 East 41 st Street Boise, ID 83714 208-345-2982 The drawing was created to asset you hvwaceng our proposal The idea erein are the proper!), c1 YESCO. Pemimion to copy w revise this drawig drawing can only he obtained Usti wrotten agreement with YESCO. © 2008 by YESCO LLC All rights reserved PRODUCTION READY U ACCOUNT EXECUTIVE: ERIC WILLIAMS DRAWN: ALSAGER DATE: 2/2/12 REV. / DATE/ DESIGNER APPROVAL: ACCOUNT EXECUTIVE: CLIENT: PROJECT NUMBER: 308150 JOB ORDER NUMBER: B47935 36'-7 " U u III 0 0 i N N EAST ELEVATION 118" = 1'•0" 69'-O " 1s'-O " no) 1. ENTRY ELEVATION ur= r•D'. alak SOUTH ELEVATION 118n = 1r_0n YESCO. Boise Division 416 East 41 st Street Boise, ID 83714 208-345-2982 This droving we mate to odic you our proposaL Wens herein m thopeof YESCO. Ponn'ssion me property cc revise this drawing dawig un only be obtained thro . writton .(ge ment with YESCO. © 2008 by YESCO LLC All rights reserved PRODUCTION READY ACCOUNT EXECUTIVE: ERIC WILLIAMS DRAWN: ALSAGER DATE: 2/2/12 REV. / DATE / DESIGNER APPROVAL: ACCOUNT EXECUTIVE: CLIENT: PROJECT NUMBER: 308150 JOB ORDER NUMBER: B47935 REMOVE MONITOR WELL 4.4o� ONE HOUR FIRE RESISTIVE WALL 4.... �•'} *44\`ii\' \1\ r=2a ARCHITECTURAL SITE PLAN N DOSING CATCH BASIN NEW LANDSCAPING WALL MOUNTED UGHTING, TYPICAL OF 7 RELOCATE VENT RISERS w/ SUPPORT LEARNING CENTER ENTRY DOOR REDBOX DVO RENTAL LOCATON TBD REQUIRED LANDSCAPE SIDE YARD REPLACE LOT LI\ POLE & FOOTING EXISTING PARKING STALLS UNDER TEMPORARY PERMIT 1230415-1-423 GRANTED 9.8.2010 0Y CITY OF �SEATTLE-CITY UGHT DEPARTMENT 4' CONVERT (1) PARING q,, STALL TO A LANDSCAPE Q3 PLANTER REPLACE LAWN WITH TYPE O,l I LANDSCAPE; 12.5' WIDE .y .N WATER • .SERVICE' MERCH. PROPOSED BLDG WALL SIGN DIMING POWER EXISTING RETAINING CURB TO REMAIN ALONG NORTHEAST PROPERLY UNE; NEW EGRESS WALK WILL BE FLUSH WITH TOP DOSTING VENT RISERS WILL BE RELOCATED RELOCATED NAT. GAS METER. CONNECT TO EXISTING SERVICE EIMERGETIC EXfT`-�L DEMOLISH EXISTING `--2:296fa-SIROCNRE NEW ELECTRICAL ROOM Q VICINITY MAP EXISTING MON TO REMAIN. TYP EXISTING FIRE HYO REMOVE OLD SIGN FOUNDATION TO GRADE REMOVE RV DUNP STATION NEW 13'-4'X10'X8' HIGH CONCRETE MASONRY TRASH ENCLOSURE w/(2) 6' HIGH.GATES REMOVE OIL WATER SEPARATOR EXISTING HI -RISE I.O. S MODIFY EXISTING PLANTER AREA PROPOSED TRUCK UNLOAD AREA; 10'X30' NEW LOT LIGHT, POLE & FOOTING REPLACE EXISTNG CANOPY w/ NEW INCLUDING NEW FOOTINGS REMOVE & REINSTALL DISPENSERS O GRADE w/GUARD P05T5. PER SECTION 312, 2009 IFC; SALVAGE DRIVE SUBS WELL N LANDSCAPING / NEW LOT UGHT, P011 & FOOTING MONO OIL WATER SEPARATOR & BASIN TO REMAIN Install new wall sign c me • o DETAIL AT SIGN n Shell a a 3 3 a a 1 3 ci YI S Z 0_ CO w 0 COW O O U J I Se • SITE DATA AW0161111 13138 INTERURBAN AVENUE S TUKWILA, WASHINGTON Ofr11111h PocWest ENERGY, LLC 3450 E. COMMERCIAL CT. MERIDIAN, ID 83642 CON174C15 JACK DAMS, 208.888.3585; ETMAIL• jockdorisOjacksonsfoodstores.com STRAtTINI 24,450SF OR 0.56 ACRES API! 0003000108 It 9..k. CgMMERCIgL/LIGHT INDUSTRIAL -,v-vim,-MARET WfTH AT CE- 09 WASH U —) ti(Np..DNOARiIIe 2,296GSF FJOSTING MIW-MARKET WfTH ATTACHED CAR WASH (d'9TE; ` CAR WASH IS NOT OPERATIONAL SPACE USED FOR MINI -MARKET STORAGE) /2\ 1,478GSF COSTING CANOPY OVER 4 NPD's 680GSF ADDITION FOR MINI -MARKET 80205E 4DR10N FOR I EARNING FNTFR 2.120GSF NEW CANOPY OVER 4 MPO'9 CONSTRUCTION WPM V-B SPRINKLERED (STORE); II-B (CANOPY) OOCIIIT�r ! M (STORE AND GAS); B (LEARNING CENTER) SCOPE OF WORK • DEMOLISH EXISTING MINI -MARKET AND CAR WASH STRUCTURE. • CONSTRUCT NEW MINI -MARKET WITH LEARNING CENTER FOR THE TRAINING OF JACKSONS' EMPLOYEES/MANAGERS. • REPLACE CANOPY OVER REFUELING AREA; REMOVE & REINSTALL (4) REFUEUNG DISPENSERS E D 0 U 030-9 0 m - 0 a 0 0 0 W GS APPLICABLE CODES ?Cr? I:IcRNATIONAL BUILDING CODE 2009 UNIFORM PLUMBING CODE 2009 INTERNATIONAL MECHANICAL CODE 2009 INTERNATIONAL FIRE CODE 2009 NATIONAL ELECTRICAL CODE 2009 WASHINGTON STATE ENERGY CODE 2003 ICC/ANSI A1117.1-2003 WASHINGTON STATE AMENDMENTS AND PUBLISHED CODE ADOPTED CODES OF THE CITY OF TUKWILA, WA CONSULTANTS ARCHITECT/ENGINEER CONTACTS. BUILDING STRUCTURAL ENGINEER: BARGHAUSEN CONSULTING ENGINEERS INC. 18205 72ND AVENUE S. KENT, WA 98032 CARYL J. MATTSON (425) 656-1063 MARK PETERSON (425) 656-7475 COLLONS+SMITH STRUCTURAL ENGINEERS 485 FRONT STREET N. w SURE F-3 ISSAQUAH, WA 98027 CONTACT: BRYAN COLLONS (425) 369-1104 PLUMBING/MECHANICAL/ELECTRICAL: ABOSSON ENGINEERING CONSULTANTS 2100 112th AVE. NE. SUITE 201 BELLEVUE, WA 98004 CONTACT: GEOTECHNICAL ENGINEER: CONTACT: GARY WOMACK - PROJECT MANAGER 425-462-9441 eat 1006 GEOTECH CONSULTANTS, INC. 13256 NE 20TH ST. SUITE 16 BELLEVUE, WA 98005 MARC McCINNIS, PE 425-747-5618 - S c o H i i ;7 E 0 1N w W CV 0" N" CNO Z ao O) N r 0 N II ▪ 3 In ui ▪ NN • tz nvl N N N �Yvv Dole/Time:1/5/2012 3:56 PM is\14700\architecturol\631 _bce 14700-1 P 0003000140 "001300004-S 13050 0003000 30 /it [ 4 'tom • .. ' � •-., q ( (C)2003KingCounty J,`{� _ G gr !:: Ol 1958ft The information included on this map has been compiled by King County staff from a variety of sources and is subject to change without notice. King County makes no representations or warranties, express or implied, as to accuracy, completeness, timeliness or rights to the use of such information. This document is not intended for use as a survey product. King County shall not be liable for any general, special, indirect, incidental, or consequential damages including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the information contained on this map. Any sale of this map or information on this map is prohibited except by written permission of King County. 13123 /', 10003000109 3310 0003000.,g3 Lend County Boundary X Mountain Peaks Highways l/ Forest Production District Boundary Agricultural Production District Boundary Urban Growth Area Line Incorporated Area Streets fiighn ay Arterials LdGsi Lakes and Large Rivers Stearns Tribal Lands Parcels Parks Unincorporated KC Zoning A=10. Agricu iural, one DU per 10 cries A=35 = Agrie uril, one DU per 35 acres F • forest �1= Mineral RA=2.3 • Rural Aron, one DU par i acres RA=5 = Rural Area, one DU per acres RA.10•Rural Arena,WIC DU pa 10acres (cont) Li n D UR=Urban Rers ,one DU per 5acres R-1= Rawl=tisi, one DU pa acre R-4= Ressd.:-atb1, 4 DU pa sera R-8 = Res ltalial, 8 CU pa acre Resxlantisl,8CUper note R=12 =Residential, 12 DU per acre R=18=Residential, 180U nacre R=24 = Residential, 24 DU puma R=3 = Residentia1,43 D U pttr acre t18 = Net Business CB = Corrunun. ty 8usress R8 • RoOonai 811371455 O=Office 1= industrial Other 2007 Color Aerial Photos ($in) 2007 Color Aerial Photos (12in) La King County Date: 3/19/2012 Source: King County iMAP - Property Information (http://www.metrokc.gov/GIS/iMAP 2401 FOOTHILL OR. SALT LAKE CITY. UT 84109 LOCATION VARIOUS LOCATIONS PHONE: 801.464.4600 WWW.YESCO.COM T.iErginwnthArhawingsZtandard WaI AmrhmentsStanderd Letter on Wal Attachment Sheets.dwg YES CO.Engineering JOB NAME WALL ATTACHMENTS DATE 01/01/2011 BY CM/AH/SJ SHT_i_ OF _J_ SINGLE FACE WALL SIGN B (20'-1" MAX) 2006 & 2009 IBC 90mph C EFS FASCIA INTERNAL FRAMING TOGGLE BOLT (SEE TABLE 3) H0 LAMPS & SOCKETS 12" OC LAMP BALLAST )f' EMT CONDUIT HANDY BOX DISCONNECT SNITCH SINGLE POLE 20 AMP RETAINERS POWERS L.OK—BOLT EXPANSION ANCHOR (SEE TABLE 3) 6'-0" MAX CMU OR CONCRETE WALL POWERS LOK—BOLT EXPANSION ANCHOR (SEE TABLE 3) Table 3. Fasteners to be used when attaching single face sign to wall type. I 1 j - Approx. Area (ft2) EFS Wood Clapboard Red Brick Concrete CMU Block Toggle bolt (into backing) Toggle bolt (into backing) Powers "Lok-Bolt" Powers "Lok-Bolt" Emb. Powers "Lok-Bolt" - --- Diameter - _ Emb. Diameter Emb. Diameter 25 --50- ._. - _ _ _ 75 ' ,(8) 1/4" (6) 3/8" _ _ (8) 1/2" (8) 1/4" (4) 1/4" 1-1/8" (4) 1/4" 1/4" (4) _ (6) 1/4" 5/8" (4) 1/4" " (4)1/4 - (6) 1/4" —. (8)-1/4" (6) 3/8" - 1-1/8" °- -" - 1-1/8 -1-1/8" - _ 1-1/8" - 1-1/2" (6) 3/8" _ _� (8) 1/2" N/A (6) 1/4" (6) 1/4" (6) 3/8" (6) 3/8" 1-1/8 . " 1-1/8" 1-1/2"_ 1-1/2"- - - -5/8' _ 1-1/8" - 100 125 N/A N/A .- - _(8) 1/4" (6) 3/8" 1-1/8" 1-1/2" -N/A - NOTES: -Type of wall fastener will vary with each wall type. -Refer to Powers documentation for proper use of the "Lok-Bolt" -Display area is calculated by (A X B = area). -Displays larger then in Table 3 require special engineering.