Loading...
HomeMy WebLinkAboutPermit S12-037 - MCDONALDS - BUILDING MOUNTED AND INCENTIVE SIGNSMCDONALDS 16501 SOUTHCENTER PKWY S12-037 3 BLDG MOUNTED & 1 INCENTIVE SIGN City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PERMANENT SIGN PERMIT Wall or Awning Face Sign Parcel No.: 5379200282 Permit Number: S12-037 Address: 16501 SOUTHCENTER PY TUKW Issue Date: Suite No: Permit Expires On: Business: MCDONALDS Property Owner: Name: MCDONALD'S CORP 046-0069 Address: PO BOX 182571 , COLUMBUS OH 43218 Contact Person: Name: BILL LYNCH Address: MEYER SIGN AND ADVERTISING , 2608 HWY 99 S Phone: 360-424-1325 Contractor: Name: MEYER SIGN AND ADVERTISING Phone: 360-424-1325 Address: 2608 HWY 99 S , MT VERNON, WA DESCRIPTION OF WORK: INSTALL 3 NEW FLUSH -MOUNTED WALL SIGNS AND 1 NEW INCENTIVE SIGN (FLUSH -MOUNTED) FOR MCDONALD'S. NOTE: 3RD SIGN IS 14 SQ FT (EBF=873 SO FT). Fees Collected: ENERGY $888.00 Zoning: TUC WALL SIGN: Total exposed building face: Permitted sign area: Area of sign: AWNING FACE SIGN: Area of awning: Sign area: Type of lighting: Type of material of awning: Type of material of sign: Wall Sign #1 591 square feet 28.64 square feet 14 square feet Awning Sign #1 0 square feet 0 square feet INCENTIVE WALL SIGNAGE: Location of Entrance: N/A Total Exposed Building Face: 900 Area of Wall: 14 Method of Lighting: INTERNAL/LED Sign Type: Electricity Provided by: PUGET SOUND Wall Sign #2 1182 square feet 52.28 square feet 42 square feet Awning Sign #2 0 square feet Awning Sign #3 0 square feet doe: WALL -AWN S12-037 Printad. OR-14-9012 Planning Division Authorized Signature. Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Signature: Print Name: Date: e' L - I THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. FINAL INSPECTION APPROVAL: DATE: doc: WALL -AWN S12-037 Printed: 08-14-2012 4 SITE INSPECTION (PLANNING) File No. S12-037 Name of Tenant: McDonalds Sign Address: 16501 Southcenter Parkway Date Photo Taken: January 8, 2013 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign inspected and final approval granted. BM, 1/08/13 We('come Jon Morrison Winters From: Jon Morrison Winters Sent: Wednesday, June 20, 2012 2:39 PM To: dsmith@fhoarch.com Subject: Permit Application #S12-037 for McDonald's Dear Mr. Smith, I have reviewed your application for a sign permit for four flush -mounted wall signs for the McDonald's restaurant at 16501 Southcenter Parkway. I determined that the proposed signs will meet code. I am ready to approve the permits. However, these permits will not be issued until a contractor is selected and I confirm that the contractor has a valid Washington State Contractor's license and a Tukwila Business License. Please contact me with the contractor information at least three days prior to picking up your permits at the permit counter. That will give me enough time put the contractor information in the permit file and inform our permitting staff that the permit is ready to be issued. This e-mail confirms that your permits do meet code and will be approved once I have received the contractor information from you. Please let me know if you have any other questions. Sincerely, Jon Morrison Winters Department of Community Development City of Tukwila jonathon.winters@tukwilawa.gov 206-431-2164 1 Jon Morrison Winters From: Jon Morrison Winters Sent: Monday, June 18, 2012 9:24 AM To: 'dsmith@fhoarch.com' Subject: Sign Permit Application #S12-037 for McDonalds Attachments: Owner Affidavit.pdf Dear Sign Permit Applicant, The City of Tukwila Department of Community Development has received your application for a sign permit. This will serve as an official notice of incompleteness. In order to make the application complete, you must provide the following within 90 days: A copy of a valid Washington State Contractor's license and the Tukwila Business License number of the Sign Contractor OR A notarized copy of the enclosed affidavit If we have not received the requested information within 90 days, your application will be cancelled. You may be granted an extension of up to 120 additional days if we receive a written request for extension. If you require assistance or if you have any questions about the permitting process, please call 206-431-2164 and reference the permit number listed above. Sincerely, Jon Morrison Winters Department of Community Development City of Tukwila ionathon.winters@tukwilawa.gov 206-431-2164 1 Freiheit & Ho architects TRANSMITTAL VIA COURIER 206-431-3670 DATE: JUNE 15, 2012 TO: City of Tukwila Community Development Department Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ATTN: Permit Center - Teri RE: McDonald's, Southcenter PROJECT NUMBER: Al2-140 NUMBER OF PAGES: 98 WE ARE SENDING YOU: (1) Sign Permit Application - 5 Pages (1) Sign Permit Check ($888.00) (3) Sign Permit Drawings — 31 Pages THESE ARE TRANSMITTED: FOR YOUR REVIEW & COMMENT REMARKS: Sincerely, FREIHEIT & HO ARCHITECTS, INC., P.S. E&4a e _,Z Derek C. Smith Architectural Designer CC: File (IFINFORMATION IS NOT RECEIVED AS INDICATED, KINDLY NOTIFY US AT ONCE) FHO TRANSMITTAL 2011 RECEIVED JUN 14 2012 COMMUNITY DEVELOPMENT TEL: 425 827 2100 FAX: 425 828 6899 WEB: www.FHOARCH.COM ADDRESS: 5209 Lake Washington Blvd N.E. I Ste 200 I Kirkland I WA ( 98033 RRRRRRRRRRRRRRRfCRRRRRRRRRftARRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRIMItftR RRRRRRRRRRRRRRRRRRRRRRRRRRfORRRRRRRRRRfCRFGRRRRRRRRRRRRRRRRRRRRRRRRRRRRR FREIHEIT E% HO ARCHITECTS INC, P.S RRRRPCRRRRRRRRRRRRRRRRRfCRRRRRRRRRRR ItrtIMMIRRRRRRRRRRRRRRRRRRRRRRRRRR •••• •••. • ?00 • e • • • • • i i • • cw . • • • • •4. Everbrite LED WORDMARK INSTALLATION AND SERVICE MANUAL Everbrite, LLC. 315 Marion Avenue South Milwaukee, WI 53172 Tel: 888-857-4078 Fax: 877-430-7363 IN449401S REV-D * • • • • Everbrite .••• ..•. ....•••••••• ;...;•. LED Wordmark Installation and Service Manual Table of Contents • Documentation and Closeout Requirements 3 • General Installation Notes and Guidelines 3 - 4 • Components Supplied 4 • Install Process 4 - 23 - Wall Mount 5 - 9 - 35' Pole Mount 10 - 16 - 46' Pole Mount 17 - 23 • Sign Service 24 - 25 RECEIVED ' JUN 1 4 20111 � oM nPME RHT WORDMARK INSTALLATION MANUAL 2 Everbrite Documentation and Closeout Requirements 1. Prior to unloading any sign components from the delivery truck the installer MUST inspect all cartons for any damage that may have occurred during shipment and document with digital photos. If said damages are present, Everbrite must be contacted immediately and the photos e-mailed to the appropriate Account Manager before any work is started. 2. Digital Photo Documentation of the completed install is required; however photos of the install process are recommended, but not mandatory. 3. All photos must be e-mailed to Everbrite Regional Account Manager upon completion of install. 4. Site must be cleaned up prior to sign off of work completed. 5. Obtain customer sign off of work completed prior to leaving the site location; Director of Operations or store owner must sign customer sign off. Note: Installer to coordinate with the assistance of the Regional Account Manager to notify Director of Operations and/or Store Owner to be on site the day of install. General Installation Notes and Guidelines 1) The sign must be lifted per the installation type. (See specific mounting instructions found in the table on contents) 2) All existing poles with the intention of being used for a product only sign supplied by Everbrite must be inspected and approved as to its design and integrity by a local engineer. 3) Use only hardware supplied by Everbrite to mount signage. No hardware is to be altered, added, or substituted without written permission from Everbrite. 4) Any replacement parts or components that require using a lock washer, requires the use of a new lock washer in replace of the existing one. 5) All mounting holes provided in sign's mounting brackets must be utilized per installation type when mounting sign structure. 6) The sign, as it is provided, must not be altered in any way without written permission and/or instruction from Everbrite, LLC. This includes: a) Wordmark plastic cabinet structure. b) All plastic faces and their plastic retainers. c) Steel back support mounting brackets. d) Steel splice/mounting bracket. e) Steel universal mounting bracket. f) All electrical components, including all wiring within sign. g) Any coatings and finishes. 7) For product only applications: The sign must be mounted in the same orientation as the previous sign. 8) For new applications: The sign must be mounted as indicated on the installation documents and instructions. WORDMARK INSTALLATION MANUAL 3 .::. • •V •: Everbrite • 9) Electrical lighting must be tested prior to field installation. In the event any components are found to be non- functional, Everbrite should be contacted immediately. 10) All final wiring terminations to be done in accordance with state and local codes. 11) This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electric Code and /or other applicable local codes. This includes the proper grounding of the sign. (Primary electrical power supply and final hook-up to be provided by a locally licensed electrical contractor) Components Supplied 1. (1) "McDo" Wordmark letter section 2. (1) "nald's" Wordmark letter section 3. (1) 85" Center splice/mounting bracket 4. (2) 6" Universal mounting brackets 5. (2) Formed end caps 6. (1) Class 2 Wire Cover 7. (85) One watt white LEDs (all are factory pre -installed) 8. (2) Amperor ANP90-30 power supplies (both are factory pre -installed) 9. (1) Hanging material kit which contains the following... - (2) 3/8" eye bolts (12) 3/8" lag shields - (12) 3/8" dia. x 1 1/2" long lag bolts (28) 3/8" dia. x 1" long screws - (28) 3/8" dia. lock washers (32) 3/8" flat washers - (4) #8 self drilling sheet metal screws Install Process: Equipment (by others): ▪ Crane with a lift capacity of at least one ton • Man -lift of sufficient reach ▪ Two 5' lift straps/chains with hooks ▪ Wire of sufficient length, from the primary electrical source to the sign with ▪ Chalk line for marking and aligning hole locations ▪ Drill with a 5/8" masonry drill bit extra added for slack WORDMARK INSTALLATION MANUAL 4 i • s • :•.:: Everbrite ••__ • • .• • .. • • Wall Mount Assembly and Install: 1. Remove both halves of the Wordmark from the carton. 2. Electrically test the two cabinets making sure to make the connection between the `0" and "n" prior to testing. WARNING — hooking up one of the two halves without this connection prior to testing will damage the LED's and/or the power supplies. 3. Using a chalk line and a 5/8" masonry drill bit, mark and drill the 5/8" dia. x 21/2" deep holes according to the diagram below. 24 1 /8" +15 5/8" ♦7 5/8" 0"— 701/4" 941/4" 1181/4" 1421/4° • 1861/8° 188 3/8° NOTE: "0" on the vertical dimension is equal to dimension from grade to the bottom of where the Wordmark is to be hung. 4. Once all of the holes are drilled and cleaned out, drop the (12) lag shields into the drilled holes. 5. Mount the center splice/mounting bracket and the two universal mounting brackets into place using (12) 3/8" dia. x 2 1/2" lag bolts and (12) 3/8" flat washers. (See diagrams below for proper orientation) Universal mounting bracket 3/8" x 2' " long lag bolt 3/8" flat washer Center splice/mounting bracket Universal mounting bracket Universal mounting 3/8" x 2' " long lag bolt Center splice/mounting Universal mountin bracket RECEIVED IJUN 1 & 20121 with 3/8" flat washer / bracket bracket COMMUNITY DEVELOPMENT WORDMARK INSTALLATION MANUAL 5 • Everbr.." ite 6. Take one of the (2) supplied end caps and using (2) #8 self -drilling screws, secure the end cap to the "McDo" back bracket. #8 self -drilling screw "McDo" Wordmark half w/ Back Bracket #8 self-drillin screw Wordmark End Cap "McDo" Wordmark half w/ Back Bracket 7. Once the mounting brackets are securely mounted to the wall and the end cap is attached, lift the "Mcdo" half of the Wordmark into place. Universal mounting bracket "McDo" Wordmark half w/ Back Bracket 3/8" x 1" bolt 3/8" lock washer 3/8" flat washer #8 self -drilling screw Center splice/mounting bracket WORDMARK INSTALLATION MANUAL 6 Everbrite 8. Using (10) 3/8" x 1" bolts, (10) 3/8" lock washers, and (10) 3/8" flat washers, mount the "McDo" Wordmark section into place with 25-30 ft/Ib of torque per bolt. "McDo" Wordmark half w/ Back Bracket #8 self-drillin screw Wordmark End Cap Center splice/mounting bracket Universal mountin bracket 9. Take one of the (2) supplied end caps and using (2) #8 self -drilling screws, secure the end cap to the "nald's" back bracket. "nald's" Wordmark half Back Bracket #8 self -drilling screw Wordmark End Cap WORDMARK INSTALLATION MANUAL 7 Everbrite 10. Lift the "nald's" half of the Wordmark into place butting both of the Wordmark back plates together. 3/8" x 1" bolt Z3/8" lock washer Ai73/8" flat washer Center splice/mounting bracket 9 Universal mounting racket 11. Using (10) 3/8" x 1" bolts, (10) 3/8" lock washers, and (10) 3/8" flat washers, mount the "nald's" Wordmark section into place with 25-30 ft/Ib of torque per bolt. WORDMARK INSTALLATION MANUAL 8 • • . • • • •�••••. :- Everbrite 12. Preparations for the wiring must be made prior to lifting the sign. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electric Code and/or other applicable local codes. This includes the proper grounding of the sign. 13. Using (2) water proof wire nuts supplied with E00940S, connect the two 30 volt black and red wires that connect the two sign halves. Tuck finished connections down behind the Wordmark out of sight. 14. Slide wire cover over wire connections in between the mask halves so it sits on the back splice plate. Bracket is held in place by a compression fit. "McDo" Wordmark half w/ Back Bracket "nald's" Wordmark half w/ Back Bracket 15. Finish wiring the 120 volt primaries into the switch box located between the "D" and the "o" at the bottom of the Wordmark. (Primary electrical power supply and final hook-up to be provided by a locally licensed electrical contractor) 16. Test light the sign. WORDMARK INSTALLATION MANUAL 9 • Everbrite .••• •••• : el • ;. . • 35' RCE Pole Mount Assembly and Install: 1. Remove both halves of the Wordmark from the carton. 2. Lay both halves of the Wordmark face down onto a protected surface and butt the two halves together. 3. Electrically test the two cabinets making sure to make the connection between the "o" and "n" prior to testing. WARNING — hooking up one of the two halves without this connection prior to testing will damage the LED's and/or the power supplies. 4. Place the center splice bracket supplied with Wordmark into both Wordmark halves as show below. Center splice/mounting bracket "nald's" Wordmark half w Back Bracket "McDo" Wordmark half w/ Back Bracket 5. Attach the center splice bracket to both Wordmark halves using (10) 3/8" dia. x 1" long screws, (10) 3/8" flat washers, and (10) 3/8" lock washers supplied with E00940S. (Use 25-30 ft/Ib of torque per bolt) Center splice/mounting bracket 3/8" flat washer 3/8" lock washer 3/8" x 1" bolt WORDMARK INSTALLATION MANUAL 10 •::• : Everbrite 6. Insert the two 3/8" dia. eye bolts supplied with Wordmark for lifting. 7. Take one of the (2) end caps and (2) #8 self -drilling screws supplied with Wordmark, secure the end cap to the "McDo" back bracket. RECEIVED 'JUN 16' 20121 COMMUNITY DEVELOPMENT #8 self -drilling screw #8 self -drilling screw #8 self -drilling screw ordmark End Cap WORDMARK INSTALLATION MANUAL 11 . . •••• Everbrite ..••••••••.. #8 self -drilling screw 8. Take the remaining end cap and (2) #8 self -drilling screws supplied with Wordmark, secure the end cap to the "nald's" back bracket. #8 self-drillin screw Wordmark End Ca #8 self -drilling screw 9. Preparations for the wiring must be made prior to lifting the sign. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electric Code and/or other applicable local codes. This includes the proper grounding of the sign. 10. Using (2) water proof wire nuts supplied with E00940S, connect the two 30 volt black and red wires that connect the two sign halves. Tuck finished connections down behind the Wordmark out of sight. 11. Slide wire cover over wire connections in between the mask halves so it sits on the back of the splice plate. Bracket is held in place by a compression fit. "McDo" Wordmark half w/ Back Bracket "nald's" Wordmark half w/ Back Bracket WORDMARK INSTALLATION MANUAL 12 ...• •...Everbrite ..•• •••. . . • • • 12. Take the (2) universal mounting brackets supplied and mount them to the RCE legs per RCE type. Legs with (4) bolt locations: Using (8) 3/8" x 1" long bolts, (8) 3/8" flat washers, and (8) 3/8" lock washers supplied, bolt the (2) brackets to the vertical RCE supports using 25-30 ft/lb of torque per bolt. Legs with (2) existing 1/2" bolts: Remove the 1/2" existing hardware on the left leg bolting the RCE vertical support to the tie -back. Using one of the universal mounting brackets, bolt the bracket to the front face of the RCE leg using the existing 1/2" hardware previously removed. Repeat these steps and mount the second mounting bracket to the right vertical RCE leg. Universal mountin bracket 3/8" flat washer 3/8" lock washer 3/8" x 1" long bolt Universal mounting bracket Existing 1/2" mounting hardware RECEIVED 'JUN 1•i 20121 COMMUNITY DEVELOPMENT 35' RCE Signage xisting RCE vertical support and tie -back WORDMARK INSTALLATION MANUAL 13 ::;. ' Fverbrite •••• ••• • •.. • w 13. Using two 5' straps, hook one end of each of the strap to the eye bolts located at the top of the Wordmark. Then hook the opposite ends of the straps up to the crane and carefully lift the Wordmark to an upright position making sure not to drag the face while lifting. 14. Carefully lift the sign into position making sure that the Wordmark is in its desired location per install and design specifications. WORDMARK INSTALLATION MANUAL 14 15. Secure the Wordmark starting at the left end using (4) 3/8" x 1" long bolts, (4) 3/8" washers, and (4) 3/8" lock washers using 25-30 ft/Ib of torque per bolt. 3/8" x 1" long screw 3/8" lock washer 3/8" flat washer 16. Secure the Wordmark at the right end using (4) 3/8" x 1" long bolts, (4) 3/8" washers, and (4) 3/8" lock washers using 25-30 ft/Ib of torque per bolt. 3/8" x 1" long scre 3/8" lock washer 3/8" flat washer WORDMARK INSTALLATION MANUAL 15 ••�� Everbrite •M• •••. •.4, • • .... 17. Once the Wordmark is fixed, remove the straps and replace the 3/8" eye bolts with (2) 3/8" x 1" long screws, (2) 3/8" lock washer, and (2) 3/8" flat washer supplied with E00940S making sure to use 25- 30 ft/Ib of torque per bolt. 3/8" x 1" long scre 3/8" lock washer 3/8" flat washer 18. Finish wiring the 120 volt primaries into the switch box located between the "D" and the "o" at the bottom of the Wordmark. (Primary electrical power supply and final hook-up is to be provided by a locally licensed electrical contractor) 19. Test light sign. WORDMARK INSTALLATION MANUAL 16 • • go. ,,. Everbrite '• :•• i• i::' • e 46' RCE Pole Mount Assembly and Install: 1. Remove both halves of the Wordmark from the carton. 2. Lay both halves of the Wordmark face down onto a protected surface and butt the two halves together. 3. Electrically test the two cabinets making sure to make the connection between the "o" and "n" prior to testing. WARNING — hooking up one of the two halves without this connection prior to testing will damage the LED's and/or the power supplies. 4. Place the center splice bracket supplied with Wordmark into both Wordmark halves as show below. Center splice/mounting bracket "nald's" Wordmark half w/ Back Bracket "McDo" Wordmark half w/ Back Bracket 5. Attach the center splice bracket to both Wordmark halves using (10) 3/8" dia. x 1" long screws, (10) 3/8" flat washers, and (10) 3/8" lock washers supplied with Wordmark. (Use 25-30 ft/lb of torque per bolt) Center splice/mounting bracket 3/8" flat washer 3/8" lock washer 3/8" x 1" bolt WORDMARK INSTALLATION MANUAL 17 Everbrite 6. Insert the two 3/8" dia. eye bolts supplied with Wordmark for lifting. 7. Take one of the (2) end caps and (2) #8 self -drilling screws supplied with Wordmark, secure the end cap to the "McDo" back bracket. #8 self -drilling screw #8 self -drilling screw #8 self-drillin screw Word End Cap WORDMARK INSTALLATION MANUAL 18 Everbrite #8 self -drilling screw 8. Take the remaining end cap and (2) #8 self -drilling screws supplied with Wordmark, secure the end cap to the "nald's" back bracket. #8 self-drillin Word End Cap #8 self -drilling screw 9. Preparations for the wiring must be made prior to lifting the sign. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electric Code and/or other applicable local codes. This includes the proper grounding of the sign. 10. Using (2) water proof wire nuts supplied with Wordmark, connect the two 30 volt black and red wires that connect the two sign halves. Tuck finished connections down behind the Wordmark out of sight. 11. Slide wire cover over wire connections in between the mask halves so it sits on the back splice plate. Bracket is held in place by a compression fit. RECEIVED JUN 1-6 20121 CLiwimmlural l r DEVELOPMENT WORDMARK INSTALLATION MANUAL 19 •.:•••: •.e• ., . .•• ••.. ... • Se.. •.:. Everbrite 12. Using the (2) universal mounting brackets supplied and mount them to the RCE legs per RCE type. Universal mountin bracket 3/8" flat washer 3/8" lock washer 3/8" x 1" long bolt Legs with (4) bolt locations: Using (8) 3/8" x 1" long bolts, (8) 3/8" flat washers, and (8) 3/8" lock washers supplied, bolt the (2) brackets to the vertical RCE supports using 25-30 ft/Ib of torque per bolt. Legs with (2) existing 1/2" bolts: Remove the I/2' existing hardware on the left leg bolting the RCE vertical support to the tie -back. Using one of the universal mounting brackets, bolt the bracket to the front face of the RCE leg using the existing 1/2" hardware previously removed. Repeat these steps and mount the second mounting bracket to the right vertical RCE leg. Universal mounting bracket Existing 1/2" mounting hardware 46' RCE Signage Existing RCE vertical support and tie -back WORDMARK INSTALLATION MANUAL 20 Everbrite 13. Using two 5' straps, hook one end of each of the strap to the eye bolts located at the top of the Wordmark. Then hook the opposite ends of the straps up to the crane and carefully lift the Wordmark to an upright position making sure not to drag the face while lifting. 14. Carefully lift the sign into position making sure that the Wordmark is in its desired location per install and design specifications. WORDMARK INSTALLATION MANUAL 21 Everbrite 15. Secure the Wordmark starting at the left end using (4) 3/8" x 1" long bolts, (4) 3/8" washers, and (4) 3/8" lock washers using 25-30 ft/Ib of torque per bolt. 3/8" x 1" long scre 3/8" lock washer 3/8" flat washer 16. Secure the Wordmark at the right end using (4) 3/8" x 1" long bolts, (4) 3/8" washers, and (4) 3/8" lock washers using 25-30 ft/Ib of torque per bolt. 3/8" x 1" long scre 3/8" lock washer 3/8" flat washer RECEIVED 'JUN 16 20121 COMMUNITY DEVELOPMENT WORDMARK INSTALLATION MANUAL 22 ..•.•••.. Everbrite • ,• • •+ •. 17. Once the Wordmark is fixed, remove the straps and replace the 3/8" eye bolts with (2) 3/8" x 1" long screws, (2) 3/8" lock washer, and (2) 3/8" flat washer supplied with Wordmark making sure to use 25- 30 ft/Ib of torque per bolt. 3/8" x 1" long scre 3/8" lock washer 3/8" flat washer 18. Finish wiring the 120 volt primaries into the switch box located between the "D" and the "o" at the bottom of the Wordmark. (Primary electrical power supply and final hook-up is to be provided by a locally licensed electrical contractor) 19. Test light sign. WORDMARK INSTALLATION MANUAL 23 aim :::: j Everbrite i i., • Sign Service: Wordmark LED & Power Supply Locations LED Wordmark Electrical Information: NEC Class 2 Electrical System with 120 Volt Primary Input: 100-240 VAC, 47-63 Hz, 2.6 Amps Max Output: 30 VDC, Voltage Regulated, 2.6 Amps Max Total Sign Output: Total Actual 120 Watts, 1.0 Amps Ballast: (2) - Amperor ANP90-30 RECEIVED JUN 15 20121 COMMUNITY OE,W—F •_ WORDMARK INSTALLATION MANUAL 24 Everbrite LED Service Instructions LED Precautions: 1. LED's can not be connected directly to voltage higher than 30 volts or the LED's will be destroyed. A low voltage (24 or 30 volts) power supply must be used and is supplied with each sign. 2. Avoid rough handling or dropping of the LED strings. Store with plastic wrap protecting the LED strings. 3. Avoid touching the actual LEDS located on the small printed circuit boards. Handle using the edges of the boards. 4. The LED boards have mounting tape on the back and need to be mounted to a clean and dry surface. Prior to adhering LED's, clean the surface with a mixture of 50/50 isopropyl alcohol. LED Trouble Shooting: 1. If none of the LED's light then it is unlikely that the LED's are bad unless the product was connected to a supply voltage higher than 30 volts without the use of a power supply. Voltage higher than 30 volts will destroy the LED's and they will all need to be replaced. LED's will last about 5 years under normal conditions using the correct low voltage power supply and in dry environment. If the problem is not the LED's then it could be a faulty switch, power supply, or wire connections and they all need to be inspected. Check with a meter that 120 volts is coming into the sign, going out of the switch, and coming into the power supply. Check with a meter that 30 volts is come out of the power supply. It is helpful to exchange questionable parts with known good parts to rule out the cause of the failure. Note: when checking the wire connections, gently pull on each wire to be sure that it is secure and making good contact. 2. If one complete string of LED's, 5 to 7 in a string, does not light then check the wire connections going to that string. 30 volts should be coming into the string. If the wires and wire nut connections are good then the driver is malfunctioning and the complete string is bad and will need to be replaced. 3. If one LED does not light then it is a bad LED and the one LED will need to be replaced. LED Replacement Instructions: CAUTION: Be sure to disconnect the power going to the sign before doing any service work on the sign. 1. Remove the faulty LED board or LED string by carefully prying off the LED board with a flat blade screw driver. Mark the location of each LED so the replacement will be in the same exact location. Cut the wires between the LEDS leaving the maximum wire lengths on the good LED. 2. Clean the surfaces with isopropyl alcohol where the replacement LED's will be placed. 3. Determine the location of the replacement LED's and cut the wires to proper length and connect the new LED's using small wire nut connectors. Use the same color code on the wires or the same orientation of the LED boards when replacing them. Test light the sign. If the replacement LED's do not Tight, then switch the wires and retest. If the new LED's do light, then continue. 4. When all LEDS work, mount the LED boards by removing the red tape liners from the tape on the LED boards, and press onto the original locations. 5. Move the wires and connectors away from the LED's to eliminate shadows on the face. Secure the wires with tape and silicone or adhesive to permanently hold the wires. WORDMARK INSTALLATION MANUAL 25 License #: BUS-0992596 Issued Date: 01/01/2012 Expiration Date: 12/31/2012 Business License UBI: 601756916 MEYERS SIGN & ADVERTISING 2608 HWY 99 SOUTH MOUNT VERNON, WA 98273 City of Tukwila Business License Nature of Business: SIGN SERVICE & INSTALL Business Name: MEYERS SIGN & ADVERTISING Business Address: 2608 HWY 99 SOUTH, MOUNT VERNON, WA 98273 FINANCE DIRECTOR P 7 LICENSEE AGREES TO COMPLY WITH ALL THE REQUIREMENTS OF CITY ORDINANCES AND STATE LAWS APPLICABLE TO THE BUSINESS ACTIVITY LICENSED HEREUNDER. This license is to be displayed conspicuously at the location of business and is not transferrable or assignable. Please note the following guidelines in the operation of your business: 1. It is necessary to contact the Finance Office at 206-431-3680 in the event your business: . Moves within the city limits of Tukwila . Moves outside the city limits . Ceases operation . Changes ownership . Changes use or type of operation . Will be having a special event (such as a tent sale, parking lot sale or any other event) outside its routine operation. 2. Additional licenses are required if your business has live music/entertainment, tow trucks, amusement devices, solicitors/peddlers, or adult entertainment. 3. Any retail sales tax generated in Tukwila needs to be reported to the Washington State Department of Revenue, under sales tax code # 1729. 4. Tukwila business license renewals are mailed to all licensed businesses in December and payable without penalty until January 31. to — 0;1 RECEIVED `JUN lfr CITY OF TUKWILA cOMMUNiIir DEvELopmENvERMANENT Department of Community Development BUILDING 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670FAX(206) 431-3665 MOUNTED SIGNS E-mail: tukplan@ci.tukwila.wa.us PERMANENT. SIGN PERMIT APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-SIBLDG Planner: File Number:., / 2 - 75 3- Needs Electrical: Yes/No Associated File Numbers: McDONALD'S Business Name DEREK C. SMITH FREIHEIT & HO ARCHITECTS, INC., P.S. 5209 Lake Washington Blvd. NE, 16501 Southcenter PKWY, Tukwila, WA 98188 Address of Sign (425)242-2468 Phone Suite 200 (425) 828-6899 Applicant/Contact Address, City, State, Zip TBD Contractor �e, el 5; yhs Phone 608 lbwy 9 y s, /-/- Vet,100 ?6G-94/ ), 01s" Address, City, State, Zip Phone I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for the City to revoke the sign permit. 05/25/2012 Date: Signature of Owner or Authorized Agent DSMITH@FHOARCH.COM Email The City will send any official notices, letters, and other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ CHECKLIST Completed and signed application (this form). Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing building mounted signs on the same building as the proposed signs. Three copies of scaled and dimensioned drawings of the proposed sign or signs with area calculations. Three copies of a scaled elevation of the building walls where the signs will be located indicating the location and dimensions of the exposed building face used to calculate the sign area. Three copies of a scaled and dimensioned building profile, if projecting signs are proposed. Method of illumination, if proposed. Method of support and attachment for building - mounted signs. Structural calculations if the sign weighs over 400 pounds. Application fee listed in current fee schedule. One copy of a valid Washington State Contractor's license or owner's affidavit. Valid Tukwila business license number for the sign contractor, if applicable: d ? / 2 1 TOTAL NUMBER OF SIGNS Total number of signs included in this application: 3 Section 1 Section 3 0 Section 2 Section 4 1 0 Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc RECEIVED JUN16*2O12 QQMM NiiY ff Building Mounted Signage Worksheet The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs, see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Section 1- Wall or Awning Face Sign Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size of your wall sign: Maximum Sign Area AREA (LxH) of Exposed Building Face (EBF) in square feet Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF-500) x .04 + 25 square feet 1501-3,000 (EBF-1,500) x .03+ 65 square feet 3,001-5,000 (EBF-3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet Sign 1X"� Sign 2 Reserved for Cit Use For more detail see the Sign Code Language, TMC 19.20.050 A. Wall Area 1821 S.F F ' / 964 S.F. 1,821 S.F. A` -'' . g 3 The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area 7 4 . 6 3 S . F F. / 4 3 . 5 6 7 4 . 6 3 S . F . ,6`1`/Sa • 7-,1), ' Calculate the maximum sign area allowed for the wall from the table above. Proposed Area of Sign 4 .4 S . F S.F. 41 S.F. j n 7 `L J� IA 7 1" Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy "M" "McDonald' s" List what the sign will say (for example name of business). Awning Face Sign Worksheet Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 B. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see TMC 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the wall from the table above. Area of Awning Face The size of an awning face sign is limited to the area from the table above or 30% of the area of the face of the awning, whichever is smaller Proposed Area of Sign Calculate the area by drawing one box around the entire sign copy using 90 degree angles. Lighting Type Only indirect lighting maybe used for awning face signs. Awning Material In commercial zones awnings may only be made of canvas or nylon fabric. Sign Material Signs may only be vinyl or paint applied directly to the awning. Sign Copy List what the sign will say (for example name of business). I This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. Q:\Department Folders\DCD\DCD Common \ Applications -Handouts, Land Use\Building Mounted Sign-May2011.doc Section 2- Incentive Signage Wall signs may also be installed on walls that do not have public entrances if the wall where the sign will be located meets at least one of the following design criteria: 1. At least 50 percent of the wall area between the height of 2 and 7 feet must be transparent with either an unobstructed view into the business or use or a display window with a depth of at least three feet. 2. Architectural detailing consistent with the building design using changes in color, materials, texture, and variations in the wall plane. 3. Artwork such as mosaic, mural or sculptural relief covers at least 50 percent of the wall surface. If the artwork uses words or images related to the business on site they will be considered part of the sign area. 4. One or more trellises covering at least 50 percent of the wall area between the height of two and seven feet, planted with climbing vines and other plant materials in a planting bed at least two feet in width and provided with permanent irrigation. Signs permitted under this Section may be up to 50 percent of the area calculated in the Table in Section 1. Sign 1 Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 F 4. Wall Area g 6 8 S . F F. �' The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area 3 9 . 72 S . F . �Q,S Calculate the maximum sign area allowed for the wall from the Table in Section 1 and reduce by half. Proposed Area of Sign 4.4 S.F. / i J / ' 7 Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy ii M u G ), List what the sign will say (for example name of business). Section 3- Projecting and Canopy Edge Signs One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and Section 2. In order to qualify for a sign under this section the business utilizing the projecting or canopy edge sign must have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The sign is not permitted to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings will qualify for a projecting or canopy edge sign. Projecting Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 C. Proposed Area of Sign Maximum area permitted is 20 square feet per face and 40 square feet total for all faces. Distance Sign Extends from Building The sign may not stick out more than four feet from the building wall. Also, the sign can't extend further than the sidewalk it overhangs. Height above ground The bottom edge of the sign must be at least eight feet above the sidewalk or walkway that it overhangs. Rotating Display Proposed Mechanical rotating displays are permitted. Sign Copy List what the sign will say (for example name of business). Canopy Edge Sign Canopy edge signs are limited to a single row of individual letters which are not permitted to extend beyond the edge of the canopy on which the sign is located. The canopy must be located over a public entrance. Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 E. Height of letters Maximum height allowed is 12 inches Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc Length of Canopy The sign length is limited to 2/3 of the length of the canopy. Length of Sign Proposed Lighting The letters may be lit, specify whether and how this is proposed. Sign Copy List what the sign will say (for example name of business). Section 4- Pedestrian Oriented Building Mounted Signage In order to encourage a more pedestrian oriented environment, the City allows the following signs in addition to those listed in sections 1, 2 and 3 of this application. Permits are only required for signs listed under this section if the signs will be discernable from any public right of way, a neighboring site or an off -site business. Not all businesses will qualify for signage under this section. Under-Awning/Canopy Signs In order to qualify for under-awning/canopy signs an entrance to a business must be provided from a public or private sidewalk. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(1). Number of signs? If located on multiple walls, list wall location. Only one permitted per business per wall. Area of sign? No sign shall exceed three square feet in area. Depth of awning or canopy? No sign may project farther from the building than its associated awning or canopy. Distance of sign from wall? Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. Awning/Canopy Side Sign In order to qualify for an awning/canopy side sign, the awning or canopy must be located above a public entrance. Also, the sign is not permitted to project beyond the edge of the awning or canopy in which the sign is located on. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(2). Number of signs? If located on multiple walls, list wall location. Only one sign permitted per business per wall. Area of awning or canopy side? Area of sign? Sign may not exceed 40 square feet of awning or canopy side area (Row @). Height of text and/or graphics? May not exceed a height of 12 inches. Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. If an awning is being used, material of awning? Awning signs may only be made of vinyl or paint applied directly to the awning. Permanent Window Signs Permanent window signs are only permitted if the following conditions are met: 1. The signs will be placed in a ground floor window that provides direct line of sight into the public area of the business. Note: Permanent window signs are not permitted in windows located along private offices, storage space, display windows or windows that are opaque or otherwise do not allow viewing into the business. 2. The placement of the permanent window signs is on the same wall as the public entrance for the business. Permanent Window Signs Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(3). Area of window? Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc Total Area of signs? No more than ten percent of the total ground floor transparent window area along the exposed building face of a business may be occupied by permanent window signs. Spandrel, opaque and mirrored glass do not qualify for window signage. No individual sign may be larger than six square feet. In no case shall the total sign area in the window, including both permanent window signs and temporary window signs, exceed 25 percent of the window area. Height of Letters and text? No window sign shall have a height greater than eight inches. Proposed Materials? The signs may be made of gold or silver leaf, vinyl or paint, applied directly to the glass; etched into the glass, neon mounted or suspended behind the glass; or framed and mounted paper signs. Method of illumination? Signs may only utilize neon tubing. INSPECTIONS A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. GENERAL The issuance of some signage within the City may require a permit from the Washington State Department of Transportation (WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\Building Mounted Sign-May2011.doc knt 00;‘,1:0V.vi`O‘O‘Ael:92.X:ixs1.11rt.i::7..-ok* .0 4L1 - SIGN NOTES (SN-01) EXISTING MONUMENT SIGN TO REMAIN; 14 SG. FT. (SN-02) NEW ARCH LOGO WALL SIGN: 14.0 50. FT.; TYPICAL OF 3. SEE ELEVATIONS FOR MORE INFORMATION. (SN-03) NEW "MCDONALD'S" WALL SIGN: 41 50. FT. SEE ELEVATIONS FOR MORE INFORMATION. (SN-04) NEW DRIVE-THRU WELCOME POINT GATEWAY: NOT INCLUDED IN SIGN PERMIT; EXEMPT DUE TO LOCATION ON SITE. DETAILS INCLUDED WITH BUILDING PERMIT. (5N-05) NEW DRIVE-THRU PRESELL BOARD: NOT INCLUDED IN SIGN PERMIT; EXEMPT DUE TO LOCATION ON SITE. DETAILS INCLUDED WITH BUILDING PERMIT. (SN-06) NEW CUSTOMER ORDER DISPLAY WITH CANOPY: NOT INCLUDED IN SIGN PERMIT; EXEMPT DUE TO LOCATION ON SITE. DETAILS INCLUDED WITH BUILDING PERMIT. (5N-01) NEW MENU BOARD: 2 NEW: NOT INCLUDED IN SIGN PERMIT; EXEMPT DUE TO LOCATION ON SITE. DETAILS INCLUDED WITH BUILDING PERMIT. SOUTHCENTER PARKWAY S 0°34'46" E 380.00' R -6029.5gI N 8°13'26- W 384.61' L=384.6 8' EXISTING McDONALD'S RESTAURANT 4,312 S.F. CO N 89°25'14" E 3' sil''SITE PLAN SCALE: 1" = 30'-0" lFreiheit & Ho architects PRLIMINARY DESIGN FOR McDONALD'S #46-0069 www.FHOARCH.COM TE4 425 827 2100 DATE: 6115112 FILE: Al2-140_PBR Sile."w, TUKWILA, WA - SOUTHCENTER . _rrrr-rrrrrrrrrrrrrr_ iI =ii� . i!! I i%.NM •.._ir_rr____rrrrrrr_r_ri..it...� . ■ . ..rrrrrr_r__rrrr_, ../tiirl.i ••• ■ . lie a9 rr_rr-rrrrrrrrrr��.lL:i..i .—_i�1l� g .l. ', 1 �r�.Iiri�. +'{■+++++44 -1 i NEW ARCH LOGO SIGN EQ. EQ. IS'-0" c .. aim s�p'i• •E rrrrrr� .r■rrr■r. r-1...,I■ram PT ---ii�� • —:�. �r■.ri■I�e' Z'..i E! ip.-.Lw5r1 i■riiii ��; - + r� .. r..__. ■. iit mil. * 1i�■ ire Emma %s_e__InaGa-�.'.i."ess� as.ri.c.c u to . 1118 rtrrrrr ■. — - ----i . . r---� F----laaaaaal \ ----�1 __,_______.Alfa.i...•.iD.o...fe.eZ.ie.o.•.•,fD.o...fo-a.-fft.v....fa.o.:mi — a.. a.o —gym M. '�'�9� y�90e �9"ay - . apr A+la`2 1• . a. �M2 _.J.i���lP iiaMilii�#.AF fie 6i— i, m om-Qin==®—•-isr-?,-6+--Mi.il--n - enni a .iMarras.w�srt=ref srs=lsisrr�srJil:ir�.gairJrgMra..r—+ar. ae L-lip lily lame- lie .i hies- lie- lies- lily .i._' --. _,.0a.. �—.Oag r7trr--Zaerror--.c.7� -.0 =-�O1:f-ram-6 .i.••i..m••� ..l••..rl••rrr ��r••rar..,�r.l�•rr.+..�l.r••r..6a. s Sorg nnsf�igeflii-geNhisg.�9 g milpihoselni i�elifiwtlr 1. NEW "McDONALD'S" SIGN. 0 0 0 EQ. IIMINOTrsen=1111E1111111111111111111111111111LIMMIIIWILWIlfirim , I 1 l l l 1 l I I 1 1 1 1 I I I I 1 1 1 ••••••••1•MO a mu :a a rams musts raw w. W---agsku .11M__...111.11111.11111101.11111•••1•1•=•111111M1=NIINNIMIIIMMINNINIM ine lam- mnam•MM ra.rrr MOOMMINrr== NEW ARCH LOGO SIGN 50'-0 1/2" 111% IL Meg' l lam ;1- , gi gg re •-)0607)-,:ie TOTAL ALLOWABLE WALL SIGN AREA: 14.63 5F PROPOSED WALL SIGN AREA: 45.4 5F OEAST ELEVATION sGA.E, IRO • 1.-0. TOTAL ALLOWABLE WALL SIGN AREA: 43.56 5F PROPOSED WALL SIGN AREA: 4.4 5F OSOUTH ELEVATION SCALE, ve• • ro' 0- Si 311* ELEVATIONS SCALE: 1/8" = 1'0" RIFreiheit & Ho architects www.FHOARCH.COM M. 425 827 2100 DATE: 6115112 FILE: Al2-140 PBR Eleve:uns..wg PRELIMINARY DESIGN FOR McDONALD'S #46-0069 TUKWILA, WA - SOUTHCENTER NEW ARCH LOGO SIGN TOTAL ALLOWABLE WALL SIGN AREA: 3q.-12 SF PROPOSED WALL SIGN AREA: 4.4 SF TOTAL ALLOWABLE WALL SIGN AREA: 14.63 SF PROPOSED WALL SIGN AREA WEST ELEVATION SCALEI VW • IV' QNORTH ELEVATION SCALE ELEVATIONS SCALE: 1/8" = 1'0" Freiheit & Ho architects www.FHOARCH.COM nu 425 827 2100 DATE: 6/15/12 FILE: Al2.140_PBR Elevetbns.dwg PRLIMINARY DESIGN FOR McDONALD'S #46-0069 TUKWILA, WA - SOUTHCENTER RECEIVED 'JUN 15 20121 COMMUNITY DEVELOPMENT Remote Power Supply: 1 -AMPEROR ANP90-30 42" Illuminated Building Arch - LED 41 7' 36 8' 3 3 FORMED BLACK ABS BACK PIGMENTED YELLOW POLYCARB PRISMATIC FACE 10 0' OUTLET HOLE ADD PS DETAILS 1/8/10 GLR REVISED NOTES 10/13/ JEE REVISED NOTES 6/12/09 RELEASED 1/21/09 GLR GLR DE971PTIW DATE CC ECM I6MSt6 RECORD FACE ATTACHMENT WITH N8 SCREWS SQUARE FOOT AREA: ACTUAL: 4.4 SO FT BOXED: 14 SQ FT N / OFF SWITCH .375" DIA MOUNTING HOLE (5) OUNTING HARDWARE INCLUDED WITH SIGN 1/4" LAG SCREWS (6) 3/8" FLAT WASHER (6) WATER TIGHT CABLE CONNECTOR SECONDARY 2 WIRE CABLE FOR 30 VOLTS, 20 FT. LONG ONE RED WIRE, ONE BLACK WIRE 30 VOLT REMOTE POWER SUPPLY (2) WIRES, BLACK AND RED, (3) WIRES, BLACK, WHITE, GREEN, TO 30 VOLT CABLE WIRES FOR 120 VOLT INPUT HOOK UP FROM SIGN LED — ILLUMINATED SIGN: NEC CLASS 2 ELECTRICAL SYSTEM POWER SUPPLY (REMOTE MOUNTED) INPUT: 100-240 VAC, 47-63 Hz, 1.3 AMPS (96W, 99VA, .99PF) OUTPUT: 30VDC, VOLTAGE REGULATED, APPROXIMATE 40 WATTS, .33 AMPS OPERATING ENVIRONMENT: WET, DAMP, DRY, —20 DEG C TO +70 DEG C IMO INSTALL INSTRUCTIONS 1. REMOVE FACE AND MARK MOUNTING AND CABLE LOCATIONS ON WALL. NOTE: USE ONLY THE HOLE LOCATIONS PROVIDED. DRILLING ALTERNATE HOLES WILL DAMAGE THE PRODUCT AND AND VOID THE WARRANTY. 2. BECAUSE CONDITIONS VARY, THE PILOT HOLE SIZE WILL VARY SO TEST WITH .187" DRILL AND ADJUST FOR THE BEST SIZE AND DRILL PILOT HOLES FOR THE 1/4" LAG SCREWS. 3. DRILL .687" DIA CLEARANCE HOLE FOR CABLE AND FITTING, 4. SILICONE CAULK ALL HOLES AND MOUNT ARCH TO WALL WITH LAG SCREWS AND WASHERS. 5. RUN 30 VOLT CABLE INSIDE THE BUILDING TO DESIRED LOCATION OF THE POWER SUPPLY. 6. MOUNT POWER SUPPLY AND RUN 120 VOLT POWER TO POWER SUPPLY AND RUN 30 VOLT CABLE AND CONNECT WIRES TO MEET ALL CODES. (SEE POWER SUPPLY ILLUSTRATION) 7. TEST LIGHT SIGN AND CHECK FOR SHADOWS. SECURE ANY LOOSE WIRES THAT CREATE SHADOWS WITH SILICONE. SECURE ANY LOOSE WIRE CONNECTIONS. 8. ATTACH FACE TO ARCH, THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND ALL OTHER APPLICABLE LOCAL CODES. THIS INCLUDES THE PROPER GROUNDING OF THE SIGN. —1.75' CAUTION. IMPROPER ELECTRICAL HOOK UP) WILL VOID WARRANTY E v e rb rite These drawings ore the exclusive property of Everbrite, Inc. • 315 HAMILN AV. Use of, or duplication in any MILWAUKEE, WI. manner 53172 without express written permission 414-762-8700 of Everbrite,LLC is prohibited. McDONALD'S LED 42' WALL ARCH WITH REMOTE POWER SUPPLY DR" GLR DT 11-4-08 aD JEE or5-20-09 sate 1.12 CRIC 46 IN449292S REV D Wordmark Fascia - LED 27-1/2" 69.85 cm. 1 18'-0" 548.2 cm. Illumination: LED Electrical: 2.6 Amps 12V 60HZ Ballast: 2- AMPEROR ANP90-30 Ship Weight: 140 lbs. Everbrite, LLC, 315 Marion Ave., South Milwaukee, WI, 53172 P: 888-857-4078 F: 877-430-7363 www.everbrite.com