HomeMy WebLinkAboutPermit S12-060 - INDUSTRIAL REVOLUTION - BUILDING MOUNTED SIGNINDUSTRIAL REVOLUTION
5835 SEGALE PARK DR C
S12-060
1 BLDG MOUNTED SIGN
City otq' ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
PERMANENT SIGN PERMIT
Wall or Awning Face Sign
Parcel No.: 3523049018 Permit Number: S 12-060
Address: 5835 SEGALE PARK DR C TUKW Issue Date: 08/24/2012
Suite No: Permit Expires On: 02/20/2013
Business: INDUSTRIAL REVOLUTION
Property Owner:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Contact Person:
Name: KAREN DOWNER
Address: 1513 CENTRAL AV S , KENT WA 98032
Phone:
Contractor:
Name: EVERGREEN SIGN CO Phone: 253-852-1354
Address: 1513 S CENTRAL , KENT WA 98032
DESCRIPTION OF WORK:
ONE WALL SIGN, "INDUSTRAIL REVOLUTION."
Fees Collected:
ENERGY
$222.00 Zoning: HI
WALL SIGN:
Total exposed building face:
Permitted sign area:
Area of sign:
AWNING FACE SIGN:
Area of awning:
Sign area:
Type of lighting:
Type of material of awning:
Type of material of sign:
INCENTIVE WALL SIGNAGE:
Location of Entrance:
Total Exposed Building Face:
Area of Wall:
Method of Lighting:
Wall Sign #1
3027 square feet
110.54 square feet
28.33 square feet
Awning Sign #1
0 square feet
0 square feet
Sign Type: Electricity Provided by: PUGET SOUND
Wall Sign #2
0 square feet
0 square feet
0 square feet
Awning Sign #2
0 square feet
Awning Sign #3
0 square feet
doc: WALL -AWN
S12-060 Printed: 08-24-2012
Planning Division Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
Signature: Date:
Print Name:
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510
for sign final inspection. Please allow up to 5 business days for your inspection.
FINAL INSPECTION APPROVAL: DATE:
doc: WALL -AWN
S12-060 Printed: 08-24-2012
File No.
Name of Tenant:
Sign Address:
Date Photo Taken:
SITE INSPECTION (PLANNING)
S 12-060
Industrial Revolution
5835 Segale Park C
September 28, 2012
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of XX/XX/200X
Make new site visit and take photo by XX/XX/200X
Comments: Sign inspected and final approval granted. BM
11 R125 2-11011i8147,
:DEPARTMENT OF LABOR AND iNDUS Rll -- _
.._ -' -,k•,y
REGISTERED AS PROVIDED BY LAW AS
CONST CONTR SIGNS
REGIST. # EXP. DATE
CCSX EVERGSC088DZ 6/7/2013
EFFECTIVE DATE 3/9/1992
EVERGREEN SIGN CO
1513 S CENTRAL
KENT WA 98032
City of Tukwila
Business License
License #: BUS-0992299
Issued Date: 01/01/2012
Expiration Date: 12/31/2012
Business License
EVERGREEN SIGN COMPANY
1513 CENTRAL AVE SOUTH
KENT, WA 98032
Nature of Business:
SIGN INSTALLATION
& REPAIRS
Business Name:
EVERGREEN SIGN COMPANY
Business Address:
1513 CENTRAL AVE SOUTH, KENT, WA 98032
p1���
FINANCE DIRECTOR feef
LICENSEE AGREES TO COMPLY WITH ALL THE REQUIREMENTS OF CITY ORDINANCES AND STATE LAWS APPLICABLE TO THE BUSINESS
ACTIVITY LICENSED HEREUNDER.
This license is to be displayed conspicuously at the location of business and is not transferrable or assignable.
J
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670 FAX (206) 431-3665
E-mail: tukplan@ci.tukwila.wa.u.s
PERMANENT
BUILDING
MOUNTED SIGNS
I'F12\I \ I.\ I SIC \ 1'EI1i\11 1 \.I'I'I.I( 11O\
FOR STAFF USE ONLY Permits Plus Type: P-SIBLDG
Planner:
Needs Electrical: Yes/No
File Number: 519, - Q ( y U
Associated File Numbers:
(NoUSTi /1L k&ter/o� 5& ,A(Pk. 1)4,c
1usiness Name Address of Sign
J LUijE? /5/3 Ci) rL4 AVES k' r
Applicant/Contact Address, City, State, Zip
FvFX6,QE-6--() &l6 -Arne
Contractor Address, City, State, Zip
`2ZS•�$3- £' &ea
Phone
- 2-/351
Phone
SAmE
Phone
I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I
understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance
of a permit or, if the permit has been issued, be cause or the City to revoke the sign permit.
Date:
Signatu of Owner or
/ ee3L @EV EE i /6M,
Email
The City will send any official notices, letters, and other official notices via email. If you wish to receive all official
communications from the City via US Postal Mail, check here: ❑
Three copies of completed and signed application
/form (this form).
c/ Three copies of a dimensioned and scaled site plan
showing property lines, streets, buildings and
parking areas; the location of all existing building
mounted signs on the same building as the
proposed signs.
Three copies of scaled and dimensioned drawings
of the proposed sign or signs with area
calculations.
Three copies of a scaled elevation of the building
walls where the signs will be located indicating the
location and dimensions of the exposed building
face used to calculate the sign area.
Nf\
Cori
Three copies of a scaled and dimensioned building
profile, if projecting signs are proposed.
jji{'AMethod of illumination, if proposed.
0l Method of support and attachment for building -
mounted signs.
Structural calculations if the sign weighs over 400
ounds.
Application fee listed in current fee schedule.
ci7One copy of a valid Washington State Contractor's
icense or owner's affidavit.
Valid Tukwila business license number for the
sign contractor, if applicable LS—O9 °r 221 °j
101 .\I. \l \11B1'.R O1+ SIC\s
Total number of signs included in this application:
Section 1
Section 3
Section 2
Section 4
W:\New Sign Code\Forms\BUILDING MOUNTED SIGNAGE.doc
Iilll��l!IL \ \\t
The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and
projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted
for your business. The application also provides the specific code standards for the common types of building mounted signs,
see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application.
!- \\.1II t \,.III!I_ I
Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall
sign maybe permitted on walls that do not have entrances, see Section 2 of this application.
Use the table below to determine the maximum permitted size' of your wall sign:
Maximum Sign Area
AREA (LxH) of Exposed Building
Face (EBF) in square feet
Permitted Sign Area
0-500
EBF x.05 or 20 square feet, whichever is larger
501-1,500
(EBF-500) x .04 + 25 square feet
1501-3,000
(EBF-1,500) x .03+ 65 square feet
3,001-5,000
(EBF-3,000) x .02+ 110 square feet
Over 5,000
150 square feet maximum
Wall Sign Worksheet
S
Sign a__
Sign
Reserved for
City Use
For more detail see the Sign Code Language,
TMC 19.20.050 A.
Wall Area
3 02:1
The size of the sign is based on the area of the
wall fronting the tenant space where the sign
will be located, see 19.08.110.
Maximum
Sign Area
``��
/ /o I S"T
Calculate the maximum sign area allowed for
the wall from the table above.
Proposed
Area of Sign
2g,33 ,L,
'N
Calculate the area by drawing one box around
the entire sign face or copy using 90 degree
angles.
Sign Copy
i u O(.1STe-M L
/2Evr7LL/770'
-
List what the sign will say (for example name
of business).
Awning Face Sign Worksheet
Sign
Sign _
Reserved for
City Use
For more deta. : - e the Sign Code Language,
TMC 19 :.150 B.
Wall Area
Th : ze of the sign is based on the area of the
all fronting the tenant space where the sign
will be located, see TMC 19.08.110.
Maximum
Sign Area
Calculate the maximum sign area allowed for
the wall from the table above.
Area of
Awning Face
The size of an awning face sign is limited to
the area from the table above or 30% of the
area of the face of the awning, whichever is
smaller.
Proposed
Area of Sign
Calculate the area by drawing one box around
the entire sign copy using 90 degree angles.
Lighting
Type
Only indirect lighting maybe used for awning
face signs.
Awning
Material
In commercial zones awnings may only be
made of canvas or nylon fabric.
Sign Material
Signs may only be vinyl or paint applied
directly to the awning.
Sign Copy
List what the sign will say (for example name
of business).
1 This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted.
W:\New Sign Code\Forms\BUILDING MOUNTED SIGNAGE.doc
_ IIC I.I_c
Wall signs may also be installed on walls that do not have public entrances if the wall where the sign will be located meets
at least one of the following design criteria:
1. At least 50 percent of the wall area between the height of 2 and 7 feet must be transparent with either an
unobstructed view into the business or use or a display window with a depth of at least three feet.
2. Architectural detailing consistent with the building design using changes in color, materials, tex and
variations in the wall plane.
3. Artwork such as mosaic, mural or sculptural relief covers at least 50 percent of the w: urface. If the artwork
uses words or images related to the business on site they will be considered part . a e sign area.
4. One or more trellises covering at least 50 percent of the wall area between t . eight of two and seven feet,
planted with climbing vines and other plant materials in a planting bed . east two feet in width and provided
with permanent irrigation.
Signs permitted under this Section may be up to 50 percent of th
ea calculated in the Table in Section 1.
Sign
Sign _
R- -rved for
ity Use
For more detail see the Sign Code Language,
TMC 19.20.050 F 4.
Wall Area
The size of the sign is based on the area of the
wall fronting the tenant space where the sign
will be located, see 19.08.110.
Maximum
Sign Area
Calculate the maximum sign area allowed for
the wall from the Table in Section 1 and
reduce by half.
Proposed
Area of Sign
Calculate the area by drawing one box around
the entire sign face or copy using 90 degree
angles.
Sign Copy
List what the sign will say (for example name
of business).
�clill_ .Ill(l (.Illt)l):, 1 ll_II
One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and
Section 2. In order to qualify for a sign under this section the business utilizing the projecting or canopy edge sign must
have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The si is not permitted
to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings wqualify for a
projecting or canopy edge sign.
Projecting Sign
Sign
Reserved for
City Use
For more detail see the Sign • de Language,
TMC 19.20.050 C.
Proposed
Area of Sign
Maximum area pe 1. ' ed is 20 square feet per
face and 40 s s - e feet total for all faces.
Distance Sign
Extends from
Building
The sign m• , not stick out more than four feet
from th- Building wall. Also, the sign can't
exte • • further than the sidewalk it overhangs.
Height above
ground
e bottom edge of the sign must be at least
eight feet above the sidewalk or walkway that
it overhangs.
Rotating
Display
Proposed
Mechanical rotating displays are permitted.
Sign Copy
List what the sign will say (for example name
of business).
Canopy Edge Sign
Canopy edge signs ar imited to a single row of individual letters which are not permitted to extend beyond the edge of
the canopy on whic the sign is located. The canopy must be located over a public entrance.
7
Sign
Reserved for
City Use
For more detail see the Sign Code Language,
TMC 19.20.050 E.
Height of
letters
_
Maximum height allowed is 12 inches
W:\New Sign Code\Forms\BUILDING MOUNTED SIGNAGE.doc
Length of
Canopy
The sign length is limited to 2/3 of the length of
the canopy.
Length of Sign
Proposed
Lighting
The letters may be lit, specify whether and how
this is proposed.
Sign Copy
List what the sign will say (for example name of
business).
l cd(_)rIclllcd \1,lllJ;I'!L'
In order to encourage a more pedestrian oriented environment, the City allows the following signs in addition to those
listed in sections 1, 2 and 3 of this application. Permits are only required for signs listed under this section if the signs
will be discernable from any public right of way, a neighboring site or an off -site business. Not all businesses will qualify
for signage under this section.
Under-Awning/Canopy Signs
In order to qualify for under-awning/canopy signs an entrance to a business must be providedom a public or private sidewalk.
Applicant's
Reserved for Use
by City Staff.
Applicable Code Language, TMC 19.20.050 (F)(1).
Number of signs?
If located on
.multiple walls,
list wall location.
Only one permitted pe . • usiness per wall.
Area of sign?
No sign shall - ceed three square feet in area.
Depth of awning
or canopy?
No sign ma; project farther from the building than
its associ. ed awning or canopy.
Distance of sign
from wall?
Distance from
ground to bottom
of sign?
Th, lowest edge of the sign must be at least eight
f et above the ground.
Awnin9fCanopy Side Sign
In order to qualify for an awning/canopy side sign, the wning or canopy must be located above a public entrance. Also, the
sign is not permitted to project beyond the edge oft awning or canopy in which the sign is located on.
Applicant's
Response
Resery d for Use
by C. y Staff.
Applicable Code Language, TMC 19.20.050 (F)(2).
Number of signs?
If located on
multiple walls,
list wall location.
Only one sign permitted per business per wall.
Area of awning or
canopy side?
Area of sign?
Sign may not exceed 40 square feet of awning or
canopy side area (Row @).
Height of text
and/or graphics?
May not exceed a height of 12 inches.
Distance from
ground to bottom
of sign?
The lowest edge of the sign must be at least eight
feet above the ground.
If an awning is
being used,
material of
awning?
Awning signs may only be made of vinyl or paint
applied directly to the awning.
Permanent Window Signs
Permanent window signs are only permitted if the following conditions are met:
1. The signs will be placed in a ground floor window that provides direct line of sight into the public area of the
business. Note: Permanent window signs are not permitted in windows located along private offices, storage
space, display windows or windows that are opaque or otherwise do not allow viewing into the business.
2. The placement of the permanent window signs is on the same wall as the public entrance for the business.
Permanent
Window Signs
Applicant's
Response
Reserved for Use
by City Staff.
Applicable Code Language, TMC 19.20.050 (F)(3).
Area of window?
W:\New Sign Code\Forms\BUILDING MOUNTED SIGNAGE.doc
Total Area of
signs?
No more tha - n percent of the total ground floor
transpar - window area along the exposed building
face : a business may be occupied by permanent
ndow signs. Spandrel, opaque and mirrored glass
do not qualify for window signage.
No individual sign may be larger than six square
feet.
In no case shall the total sign area in the window,
including both permanent window signs and
temporary window signs, exceed 25 percent of the
window area.
Height of Letters
and text?
No window sign shall have a height greater than
eight inches.
Proposed
Materials?
The signs may be made of gold or silver leaf, vinyl
or paint, applied directly to the glass; etched into the
glass, neon mounted or suspended behind the glass;
or framed and mounted paper signs.
Method Of
illumination?
Signs may only utilize neon tubing.
/\SIT( ]Iu\',S'
A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to
schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for
scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection
It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at
(206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection.
(,1: \LK IL
The issuance of some signage within the City may require a permit from the Washington State Department of Transportation
(WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For
information on permits that may be required from WSDOT call (360) 705-7296.
The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions
of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this
code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other
data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC
19.12.020 (C)).
Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The
Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the
180 day period.
W:\New Sign Code\ Forms\ BUILDING MOUNTED SIGNAGE.doc
INDUSTRIAL
REVOLUTION
10'-0 I'
120" x 34" x V2" Aluminum Backer Panel
Painted Mathews Duranodic (MAP 26077) + Clear Coat
1" x'/2" Raised Borders
Painted Mathews Gold (MAP 21606) + Clear Coat
EVERGREE
1513 South Central Kent, Washington 98032
Tel: 253 852-1354 Fax: 253 850-5911
E Mail: karend@evergreensign.com
Customer:
Project Name:
File Name:
Scale:
Date:
Comments:
Industrial Revolution
Segale Park Exterior Wall Sign
IR Wall Sign.cdr
3/4" =1'-0" Revision: 1
August 22, 2012
These drawings are the exclusive property of Evergreen Sign Company
They represent chargeable time spent. They are submitted for your
personal use with the agreement that the use of this design in its
entirety or any part will not be reproduced, copied, lent or used for any
purpose without written consent from Evergreen Sign Company.
Customer Approval:
Title: Date:
Member:
Mai
r smiauu
e
e
a
a
0
Screen & Graphic Image Association
NTERNATIONAL SIGN ASSOCIATION
•
91'-8"
120" x 34" x 1" Aluminum Sign (28.33 sf)
Building Facade = 3027 sf
Mounted to Building Facade on Two 4 foot Aluminium French Cleats
Concrete Nail -Ins 12" OC
EVERGREE
Customer:
Project Name:
1513 South Central Kent, Washington 98032 File Name:
Tel: 253 852-1354 Fax: 253 850-5911 Scale:
E Mail: karend@evergreensign.com
Industrial Revolution
Segale Park Exterior Wall Sign
IR Segale Exterior v3.cdr
1" = 1'-O" Revision: 3
Date: August 9, 2012
Comments:
•
P
(17
ctgr
• O
O J C?
O
.25" x 2" Nylo : a 1�i Anct� �.
- 3/32' Dia �eter� I�
- 10' Mg : co.•V/`
These drawings a e the exclusive property of Evergree Companel
They represent chargeable time spent. They are submitted fo
personal use with he agreement that the use of this design in its
entirety or any par will not be reproduced, copied, lent or used for any
purpose without written consent from Evergreen Sign Company. 111=1111191111111
•
Concrete
Aluminum Cleat Welded
to Back of Sign Frame
Customer Approval:
Title: Date:
I VI
INTERNATIONAL SIGN ASSOCIATION
IAI
Screen & Graphic Image Associac+on