Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit S12-092 - SOUND TRANSIT SOUNDER STATION - MONUMENT SIGNS
SOUNDER STATION @ LONGACRES 7301 LONGACRES WAY S12-092 2 MONUMENT SIGNS City oPfukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 2423049029 Address: Suite No: 7301 LONGACRES WY TUKW Applicant/Business: MONUMENT SIGN PERMIT Commerical/Industrial Zones SOUND TRANSIT SOUNDER STATION Permit Number: Issue Date: Permit Expires On: S12-092 08/26/2013 02/22/2014 Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SOUND TRANSIT KYM WILLIAMS 401 JACKSON ST , SEATTLE WA 98104 OWNER AFFIDAVIT ON FILE Phone: (206) 398-5156 Phone: DESCRIPTION OF WORK: 2 STATION MONUMENT SIGNS SOUND TRANSIT SIGN NORTH ENTRANCE LONGACRES- STATION IDENTIFICATION SIGN (SOUTH ENTRANCE STRANDER - STATION IDENTIFICATION SIGN IS CONSIDERED NOT DISCERNIBLE AND THEREFORE REQUIRES NO PERMIT. AMTRAK SIGN MASTER SIGN PERMIT APP Fees Collected: $444.00 Electricty Provided by: PUGET SOUND ENERGY Name of street frontage: Total sign area per face: Total sign area per sign: Total sign size per face: Total sign size per sign: Width of sign: Height of sign: Distance from closest edge of sign to property lines: Monument # 1 Longacres Way 40 square feet 80 square feet 49 square feet 98 square feet 8 feet 4 inches 6 feet 10 inches 0 feet Monument #4 Zoning: TUC Monument #2 0 square feet 0 square feet 0 square feet 0 square feet 0 feet 0 inches 0 feet 0 inches 0 feet Monument #5 Sign Type: MON-GRAN Monument #3 0 square feet 0 square feet 0 square feet 0 square feet 0 feet 0 feet 0 feet Monument #6 0 inches 0 inches ***continued on next page*** doc: SIGN-MON S12-092 Printed: 08-26-2013 Name of street frontage: Total sign area per face: Total sign area per sign: Total sign size per face: Total sign size per sign: Width of sign: Height of sign: Distance from closest edge of sign to property lines: 0 square 0 square feet 0 square feet 0 square feet 0 feet 0 inches 0 feet 0 inches 0 feet 0 square feet 0 square feet 0 square feet 0 square feet 0 feet 0 inches 0 feet 0 inches 0 square feet 0 square feet 0 square feet 0 square feet 0 feet 0 inches 0 feet 0 inches 0 feet 0 feet Planning Division Authorized Signature: Date: d?/ 773 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. Signature Date: g/G 4/3 Print Name: To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. FINAL INSPECTION APPROVAL: DATE: ***continued on next page*** doc: SIGN-MON S12-092 Printed: 08-26-2013 File No. Name of Tenant: Sign Address: Date Photo Taken: x SITE INSPECTION (PLANNING) S 12-092 SOUND TRANSIT SOUNDER STATION 7601 LONGACRES WAY January 17, 2014 Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of 1/16/2014 Make new site visit and take photo by XX/XX/200X Comments: Final approval not granted. MB 1-17-2014 �15 14-0 AMTRAK Kiosk Signage at Tukwila Station 7301 Longacres Way, Tukwila S12-092 — permit for Grand Monument and Amtrak Kiosk sign - This application/plans show original plans for the Amtrak Kiosk — submitted by Sound Transit — the plans were for a "freestanding" sign on two posts. The Amtrak sign was later altered — the posts were going to be cut off and the sign placed on a "seat wall' - this alteration shows on a building permit and was also approved by the planning department. S12-092 expired S14-0085 was applied for in its place — for the Grand Monument ONLY - minus the Amtrak sign — The Amtrak portion was re -applied for separately on S14-0042 S14-0042 showed the original freestanding Amtrak Kiosk/Sign plans from S12-092 (NOT the seat wall that was changed on a building permit), however the sign was moved to a non -discernable location and approved by planning. S14-0042 was "issued" as paperwork only, using the original "Freestanding plans" from S12-092 — (AMTRAK decide not to go with the Seat Wall, and to go back to the original free standing sign) - these plans are copied and placed in this file. Also, this sign was moved to a non -discernable location. On November 3, Trade -Marx came in and Applied for the exact same Amtrak Kiosk/Sign. S14-0088 Per Kym Williams at Sound Transit, the submittal from Trade -Marx is to be voided and a refunded issued. Sound Transit will handle the specific contractor used (without City involvement) as Sound Transit has the permit (S14- 0042) under an Owner's Affidavit. City of Tukwila Jim Haggerton, Mayoi Department of Community Development Jack Pace, Director Notice of Incomplete Application 24 December 2012 Kym Williams, Permit Administrator Sound Transit Union Station 401 S Jackson St. Seattle WA 98104-2826 Subject: Permanent Freestanding Sign Application - S12-092 7301 Longacres Way Dear Kym: Your application for the above decision is incomplete. The following items must be completed before a decision can be made on this application. 1. Approval of a Master Sign Program. Here is the link to that application, http://www. ci.tukwila.wa.us/dcd/apps/Sign-MasterProgram.pdf. 2. One copy of a valid WA State Contractor's license or owner's affidavit. (The sign contractor will be required to have a Tukwila Business License.) The Master Sign Program requires the approval of the City's Board of Architectural Review, (BAR.) The sign application may not be issued until that approval has been given by the BAR. The sign application will expire if we do not receive the additional information within ninety days of the date of this letter, unless an extension is granted pursuant to Permit Application Types and Procedures Section of the Municipal Code, (TMC18.104.070(E).) Please contact me with any questions at (206) 431-3651 or moira.bradshaw@tukwilawa.gov. Sincerely, Moira Carr Bradshaw Senior Planner W:\L.ong Range Projects\SoundTransit\Sounder\Signs\notice of incomplete sign app.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 Attachment W:\Long Range Projects\SoundTransit\Sounder\Signs\notice of incomplete sign app.doc Page 2 of 2 CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING •.[lease print name] RECEIVED AUG 14 2013 • COMMl1Nl 1 Y DEVELOPMENT , states as follows: PERMIT NO: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number /3, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Owne wner's Agent* Signed and sworn to before me this 1 -17 day of A-v..se,s± , 2013 . 4/0 ci/401C/C NOTARY PUBLIC in and for the State of Washington Residing at Name as commissioned: My commission expires: , County 1D�11'�b 18.27.090 Exemptions. The reg tion provisions of this chapter do not apply tt 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 ROW that employs a certified journeyman electrician, a eertified residential specialty electrician, or an electricaPtrainee meeting,the requirements of chapter 9128 RCW to peiformplumbing work that is incidentally, directly, and immediately appropriate to the like m kind replacement of a iousehold appliance or other small household utilization=equipment that requires limited electric power rind lim ted waste and/or water connectionsy.Anelectrical:trainee must be supervised by a certified=eleetrieian while,;performing plumbing work. "F` • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. CITY O TU�� KWILA Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 Telephone: (206) 431-3670FAX(206) 431-3665 E-mail: signpermits a,TukwilaWa.gov PERMANENT FREESTANDING SIGNS PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-SIFREE RECEIVED Planner: File Number: 5i io Qk Needs Electrical: Yes/No Associated File Numbers: 5/516.JGa l 5(1 Business Name f �JLII�S Con-ct Name tL YYI . (".)i I it lh,+.c 11emu Colitact Email address Address of Sign 4(0l J c--5A-2--. Address Contractor Contractor State License # ' (,()tof/1)I JI I r I)I:VI.LUI'ML-N r City, State, Zip L 31k'S i5� Contact Phone number Contractor's City of Tukwila Business Lic # Contractor Address City St Zip I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be cause for the City to revoke the sign permit. 6.7415 Date: Signa l;. e of Owner or Authorized Agent Ethic The City will send any official notices, letters, and other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ CHECKLIST O Completed and signed application (this form). O Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing freestanding signs on the premise and proposed location for any new freestanding sign(s). O Method of illumination, if proposed. O Scaled and dimensioned footing designs and height calculations. Footing designs are not required for reface or copy changes to an existing freestanding sign, provided there is no change in the sign height, area or location. O Structural calculations if the sign has an area greater than 50 square feet and/or is taller than 15 feet. This requirement may be waived for certain refaces or copy changes to existing freestanding signs. O Application fee listed in current fee schedule. O One copy of a valid Washington State Contractor's license or owner's affidavit. O Valid Tukwila business license number for the sign contractor. TOTAL NUMBER OF SIGNS Total number of signs included in this application: Section 1 Section 3 Section 2 Section 4 W:\Applications-Handouts, Land Use\2013 Modified Sign Permits \ Freestanding Sign-updated.doc General Information about Property Total Length of Street Frontage Along All Streets: 'Z 7J 4 3g5 Does the site front on more than one street, but have less than 800 feet of linear frontage, combined on both streets? yes Is the site use a multi family or institutional use in a residential zone (LDR, MDR, or HDR)? Ii'D Freestanding Sign Worksheet A sign permit is required for the installation of a new freestanding sign. In most circumstances the City only allows new freestanding signs to be monument style signs. Certain large premises that have gone through the Master Sign Program are eligible for grand monument signs. Information on installing a new freestanding sign is found in SECTION 1 of this application. Information on installing new grand monument signs can be found in SECTION 2 of this application. A sign pennit is also required for any proposed reface or copy change to an existing freestanding sign in the City. In some cases a reface or copy change of an existing freestanding sign requires that the sign be removed. Information on completing a reface or doing a copy change to an existing freestanding sign can be found under SECTION 3 of this application. Section 1- New Freestanding Signs Freestanding Signs in Commercial/Industrial Zones Each premise is permitted to have one freestanding -monument style sign. Additional monument signs are permitted based on the total amount of linear street frontage along the premise. Table 1 below outlines the development standards and total number of signs permitted for most premises. Total ROW of Premise Allowable Sign Message Areal Total Allowable Sign Size2 Maximum Height Number of Signs Less than 400 feet 36 square feet per side/72 square feet total 54 square feet per side/108 square feet total 6 feet One 400-599 feet 50 square feet per side/100 square feet total 70 square feet per side/140 square feet total 7 feet One 600-799 feet 60 square feet per side/120 square feet total 80 square feet per side/160 square feet total 7 feet One 800-999 feet 66 square feet per side/132 square feet total 88 square feet per side/176 square feet total 8 feet Two 1,000 feet and over 72 square feet per side/144 square feet total 96 square feet per side/192 square feet total 8 feet One for every 400 feet of linear street frontage. Corner Properties Some corner properties may qualify for more than one monument sign, even if they have a limited amount of street frontage. A property that borders on more than one public street, but has less than 800 total feet of linear frontage, is permitted to have one monument sign per street if the following criteria are met: 1. The property has a least 200 feet of frontage on each public street where a sign will be placed; 2. Each public street provides direct access to the property; and 3. For each separate street frontage Table 1 listed above shall be used to determine the design standards for any proposed monument sign. General Requirements for Monument Signs in Commercial and Industrial Zones 1. Setback. All monument signs shall be placed at a minimum of five feet from all property lines; however no sign taller than three feet shall be placed within the sight distance triangle, unless it can be demonstrated the sign will not pose a safety risk by reducing visibility for motorists turning out into traffic. 2. Maximum Width. The maximum width permitted for any new monument sign is 15 feet, 3. Address Requirement. All new freestanding signs shall have the address number or address range of the premise listed on the structure. The address shall not be counted toward the allowable sign message area limit. Address numbers must be plainly legible and visible from the street fronting the property. The address numbers must contrast with the sign background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches high with a minimum stroke width of 1.5 inches. The allowable message area is either the face pane of the sign, or for channel letters or signs painted on seating or retaining walls, that portion of the sign devoted to the actual message , logo, or business name. 2 Total size is the entire area of the sign, including the support structure. W:\Applications-Handouts, Land Use\ 2013 Modified Sign Permits\Freestanding Sign-updated.doc • ltA.3‘ Table 1, Monument Sign Detai s, �o nercia!/Industrial Zones Monument Sign 1 onument Sign 2 Monument Sign 3 Monument Sign 4 Monument Sign 5 Monument Sign 6 Name of Street on which sign will be placed? " co • 7jt . ie i Total Sign message area per face. ii& 5 f •I~' -� �� Total Sign message area per sign. Total Sign Size per face , 1G _ Total Sign Size per sign. ' #C-�f LT �T Width of Sign it / i+ S'7-14 PI Sign Height (feet -inches) r l iti r (, Distance from closest edge of sign to property lines (in feet) , 1-t:. II .I-1.19 L. 1 'IA,(Q� 0 SO (` Freestanding Signs in Residential Zones Institutional uses and multi -family complexes are allowed to have one monument sign for each public street that provides access to the premises. The following are the specific development standards that apply to the installation of monument signs in residential zones: 1. The area of the monument sign is limited to 30 square feet per sign face and a total of 60 square feet for all sides; 2. The sign may be up to five feet tall; 3. Maximum width of the sign shall not exceed 15 feet; 4. Location of the sign shall not interfere with sight distance of vehicles pulling in and out of the premises; 5. The sign must be located in a landscaped area. Having the sign stand-alone in a parking lot is not permitted; and 6. The sign may only use indirect lighting methods except for dynamic displays. The lighting must have no spill -over impact on adjacent properties. Dynamic Signs in Residential Zones In order to foster civic community outreach and communication, the City permits limited use of dynamic signs within residential zones. One permitted monument sign per premise, as outlined above, may contain a dynamic feature. The following are the specific development standards applicable to the installation of dynamic signs within residential zones: 1. The image of the sign may not change more frequency than once every ten seconds; 2. The image must appear and disappear as one image. The image may not appear to flash, undulate, pulse or portray explosions, fireworks, flashes of light, or blinking or chasing lights, or appear to move toward or away from the viewer, expand, contract, bounce, rotate, spin, twist, scroll, travel or otherwise portray movement. 3. Illumination of the dynamic sign is limited to the hours of 7AM to 10PM. 4. All signs shall have installed ambient light monitors, and shall at all times allow such monitors to automatically adjust the brightness level of the electronic sign based on ambient light conditions. Maximum brightness levels for electronic signs shall not exceed 3-foot candle above ambient light conditions, measured 100 feet from the face. Tabe2, Monument Sign Details, Residential Zones Monument Sign 1 Monument Sign 2 Monument Sign 3 Monument Sign 4 Name of Street in which sign will be placed along? Total Area of Sign. Sign Height (feet -inches) Width of Sign. Will the sign have a Dynamic Display? W:\Applications-Handouts, Land Use\2013 Modified Sign Permits\Freestanding Sign-updated.doc Section 2- Grand Monument Signs Premises that have an approved Master Sign Program are eligible to install two grand monument signs. A grand monument sign takes the place of one of the monument signs permitted in section 1 of this application. The design of the grand monument sign shall have an architectural treatment that is consistent with the design of the building or buildings on premise in which the sign will be located. Before you fill out this section you should first see if the premise you are applying for has an approved Master Sign Program. If not, your first step is to submit a master sign permit application. The City will not issue a permit for a grand monument sign until the Master Sign Program is approved by the City. Table 3, Grand Monument Sign Details Grand Monument Sign 1 Grand Monument Sign 2 Reserved for Staff Use For more detail see TMC 19.32.060 (B)(2). Street in which sign will be placed along? (_,,, ..e_,,t.S („1 ece. aw.e...• Each grand monument sign would substitute for one monument sign permitted in Table 1 listed above. Maximum of two grand monument signs per premise. Total Sign Area per face. ,C. '•� 7 Sign message area may be increased up to 100 square feet per side, 200 square feet total. For sites over 85 acres, the sign message area may be increased up to 500 square feet per side, 1000 square feet total. Total sign area per sign. 1 4 `A� Total Sign Size per face 5'- No limitation on total structure size. Total sign size per sign. 5 Sign Height (feet -inches) +4 iq ry Height of the sign structure may not exceed the height of the tallest building on the premises, except for sites over 85 acres, the height may exceed the tallest building but shall not exceed 115 feet. Height of Tallest Structure on the premise where the grand monument sign will be located? -I- 2'; Distance from closet edge of sign to property lines (in feet) ÷5)i The sign must be setback from the side and rear property lines of the premise a distance equal to the height increase requested or five feet, whichever is greater. The minimum front setback is the smaller of the front yard required in the zoning district or the height increase requested. W:\Applications-Handouts, Land Use\ 2013 Modified Sign Permits\Freestanding Sign-updated.doc Section 3- Reface and Copy Change of Existing Freestanding Signs When the current sign code became effective on August 24, 2010, the City strived to create a sign code that would reduce the impact to property owners and businesses that had existing freestanding signs on their property. The city permits refaces and copy changes to existing freestanding signs under several different scenarios: 1. A freestanding sign that conforms to the current sign code is permitted refaces and copy changes with a permit. 2. A freestanding sign that is not considered a freeway interchange sign, which was legally installed under the previous sign code but does not meet the current Sign Code, is pennitted to have refaces and copy changes for up to TEN years from the effective date of the City's Sign Code (8/24/10). A permit is required for any reface or copy change. Please note, modifying the sign height, increasing the sign area, or relocating the sign is not pennitted without bringing the sign into full conformance with the City's Sign Code. At the end of the ten year period the sign may remain as -is indefinitely, however additional refaces or copy changes will require that the sign be brought into conformance with the Sign Code. 3. A freestanding sign that is considered a freeway interchange sign and was legally installed under the previous sign code is permitted to have refaces and copy changes for up to FIVE years from the effective date of the City's Sign Code (8/24/10). A permit is required for any reface or copy change. Please note, modifying the sign height, increasing the sign area, or relocating the sign is not pennitted. At the end of the five year period the sign may remain as -is indefinitely, however any changes to the face or structure of the sign will require that the sign be removed. 4. Freestanding signs that did not comply with the City's previous sign code, for example those that were installed while an area was in King County, are not permitted to have any changes to the face or structure of the sign without bringing the sign into conformance with the Sign Code. Staff can help you research previous permit history to determine if your existing freestanding sign was installed under the provisions of the City's previous Sign Code. You will note that under Section 1 of this sign permit application additional signs are allowed for premises with over 800 feet of linear street frontage or for corner properties. Even if your property qualifies for this additional signage under Section 1 you will not be able to install it until any existing non -conforming sign(s) are removed (TMC 19.36.070). Table 4. Existing Freestandinff Sign Details Existing Freestanding Sign 1 Existing Freestanding Sign 2 Notes: Date of last sign permit issued by the City for sign that is being modified: Existing Sign Area: Proposed Sign Area: Sign Height (feet -inches): Distance from closet edge of sign to property lines (in feet): W:\Applications-Handouts, Land Use\2013 Modified Sign Permits \Freestanding Sign-updated.doc INSPECTIONS A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. GENERAL The issuance of some signage within the City may require a permit from the Washington State Department of Transportation (WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. W:\Applications-Handouts, Land Use\2013 Modified Sign Permits \ Freestanding Sign-updated.doc RFC!. DEC 20201121 CITY OF TUKWILA PERMANENT mannaler Department of Community Development FREESTANDING 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 SIGNS E-mail: signpermits(a TukwilaWa.gov PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-SIFREE Planner: File Number: S `. - V q a Needs Electrical: Yes/No Associated File Numbers: Business Name `7 a,o1 t,DA-h" Address of Sign ► t LL t>t S Isv14-PD s Cr 4C1-rfl-_ 98104 Applicant/Contact_Address, City, State, Zip { lthD Contractor Address, City, State, Zip 2 e .S[ Phone SA-0+E Phone Phone I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been issued, be causeor the City to revoke the sign permit. Date: Signatu e of Owner or Authorized Agent titt/� .u,%/, i/, sL - Eniail The City will send any official notices, etters, and other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ CHECKLIST O Completed and signed application (this form). W Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing freestanding signs on the premise and proposed location for any new freestanding sign(s). O Method of illumination, if proposed. 1.�/A CY Scaled and dimensioned footing designs and height calculations. Footing designs are not required for reface or copy changes to an existing freestanding sign, provided there is no change in the sign height, area or location. O Structural calculations if the sign has an area greater than 50 square feet and/or is taller than 15 feet. This requirement may be waived for certain refaces or copy changes to existing freestanding signs. K %A O Application fee listed in current fee schedule. O One copy of a valid Washington State Contractor's license or owner's affidavit. O Tukwila business license number for the sign contractor, if applicable: TOTAL NUMBER OF SIGNS Total number of signs included in this application: Section 1 Section 3 Section 2 Section 4 General Information about Property 2 SI61eS Total Length' of Street ro ong A Does the site front on more than one street, but have less than 800 feet of linear frontage, combined on both streets? stitul n� residential ;zone (LDR, MDR, Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code)\Freestanding Sign-updated.doc Freestanding Sign Worksheet A sign permit is required for the installation of a new freestanding sign. In most circumstances the City only allows new freestanding signs to be monument style signs. Certain large premises that have gone through the Master Sign Program are eligible for grand monument signs. Information on installing a new freestanding sign is found in SECTION 1 of this application. Information on installing new grand monument signs can be found in SECTION 2 of this application. A sign permit is also required for any proposed reface or copy change to an existing freestanding sign in the City. In some cases a reface or copy change of an existing freestanding sign requires that the sign be removed. Information on completing a reface or doing a copy change to an existing freestanding sign can be found under SECTION 3 of this application. Section 1- New Freestanding Signs Freestanding Signs in Commercial/Industrial Zones Each premise is permitted to have one freestanding -monument style sign. Additional monument signs are permitted based on the total amount of linear street frontage along the premise. Table 1 below outlines the development standards and total number of signs permitted for most premises. Total ROW of Premise Allowable Sign Message Areal Total Allowable Sign Size2 Maximum Height Number of Signs Less than 400 feet 36 square feet per side/72 square feet total 54 square feet per side/108 square feet total 6 feet One 400-599 feet 50 square feet per side/100 square feet total 70 square feet per side/140 square feet total 7 feet One 600-799 feet 60 square feet per side/120 square feet total 80 square feet per side/160 square feet total 7 feet One 800-999 feet 66 square feet per side/132 square feet total 88 square feet per side/176 square feet total 8 feet Two 1,000 feet and over 72 square feet per side/144 square feet total 96 square feet per side/192 square feet total 8 feet One for every 400 feet of linear street frontage. Corner Properties Some corner properties may qualify for more than one monument sign, even if they have a limited amount of street frontage. A property that borders on more than one public street, but has less than 800 total feet of linear frontage, is permitted to have one monument sign per street if the following criteria are met: 1. The property has a least 200 feet of frontage on each public street where a sign will be placed; 2. Each public street provides direct access to the property; and 3. For each separate street frontage Table 1 listed above shall be used to determine the design standards for any proposed monument sign. General Requirements for Monument Signs in Commercial and Industrial Zones 1. Setback. All monument signs shall be placed at a minimum of five feet from all property lines; however no sign taller than three feet shall be placed within the sight distance triangle, unless it can be demonstrated the sign will not pose a safety risk by reducing visibility for motorists turning out into traffic. 2. Maximum Width. The maximum width permitted for any new monument sign is 15 feet, 3. Address Requirement. All new freestanding signs shall have the address number or address range of the premise listed on the structure. The address shall not be counted toward the allowable sign message area limit. Address numbers must be plainly legible and visible from the street fronting the property. The address numbers must contrast with the sign background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches high with a minimum stroke width of 1.5 inches. The allowable message area is either the face pane of the sign, or for channel letters or signs painted on seating or retaining walls, that portion of the sign devoted to the actual message , logo, or business name. 2 Total size is the entire area of the sign, including the support structure. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code) \Freestanding Sign-updated.doc Table 1, Monument Sign Details, Commercial/Industrial Zones Monument Sign 1 Monument Sign 2 Monument Sign 3 Monument Sign 4 Monument Sign 5 Monument Sign 6 Name of Street on which sign will be placed? Total Sign message area per face. Total Sign message area per sign. Total Sign Size per face Total Sign Size per sign. Width of Sign Sign Height (feet -inches) Distance from closest edge of sign to property lines (in feet) Freestanding Signs in Residential Zones Institutional uses and multi -family complexes are allowed to have one monument sign for each public street that provides access to the premises. The following are the specific development standards that apply to the installation of monument signs in residential zones: 1. The area of the monument sign is limited to 30 square feet per sign face and a total of 60 square feet for all sides; 2. The sign may be up to five feet tall; 3. Maximum width of the sign shall not exceed 15 feet; 4. Location of the sign shall not interfere with sight distance of vehicles pulling in and out of the premises; 5. The sign must be located in a landscaped area. Having the sign stand-alone in a parking lot is not permitted; and 6. The sign may only use indirect lighting methods except for dynamic displays. The lighting must have no spill -over impact on adjacent properties. Dynamic Signs in Residential Zones In order to foster civic community outreach and communication, the City permits limited use of dynamic signs within residential zones. One permitted monument sign per premise, as outlined above, may contain a dynamic feature. The following are the specific development standards applicable to the installation of dynamic signs within residential zones: 1. The image of the sign may not change more frequency than once every ten seconds; 2. The image must appear and disappear as one image. The image may not appear to flash, undulate, pulse or portray explosions, fireworks, flashes of light, or blinking or chasing lights, or appear to move toward or away from the viewer, expand, contract, bounce, rotate, spin, twist, scroll, travel or otherwise portray movement. 3. Illumination of the dynamic sign is limited to the hours of 7AM to l OPM. 4. All signs shall have installed ambient light monitors, and shall at all times allow such monitors to automatically adjust the brightness level of the electronic sign based on ambient light conditions. Maximum brightness levels for electronic signs shall not exceed 3-foot candle above ambient light conditions, measured 100 feet from the face. Tabe2, Monument Sign Details, Residential Zones Monument Sign 1 Monument Sign 2 Monument Sign 3 Monument Sign 4 Name of Street in which sign will be placed along? Total Area of Sign. Sign Height (feet -inches) Width of Sign. Will the sign have a Dynamic Display? Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code) Freestanding Sign-updated.doc Section 2- Grand Monument Signs Premises that have an approved Master Sign Program are eligible to install two grand monument signs. A grand monument sign takes the place of one of the monument signs permitted in section 1 of this application. The design of the grand monument sign shall have an architectural treatment that is consistent with the design of the building or buildings on premise in which the sign will be located. Before you fill out this section you should first see if the premise you are applying for has an approved Master Sign Program. If not,your firs t step is to submit a master sign permit application. The City will not issue a permit for a grand monument sign until the Master Sign Program is approved by the City. Table 3, Grand Monument Sign Details Grand Monument Sign 1 Grand Monument Sign 2 Reserved for Staff Use For more detail see TMC 19.32.060 (B)(2). Street in which sign will be placed along? Laztausis^�eias WA-4r — 70 ' sr %TUCK t{ GR ACCESS Del U E Each grand monument sign would substitute for one monument sign permitted in Table 1 listed above. Maximum of two grand monument signs per premise. Total Sign Area per faced ,SF 2� SF Sign message area may be increased up to 100 square feet per side, 200 square feet total. For sites over 85 acres, the sign message area may be increased up to 500 square feet per side, 1000 square feet total. Total sign area per sign. (gct S.p. [ ,q a �� t Total Sign Size per face iel SF 31 SF No limitation on total structure size. Total sign size per sign. le' SF C,1. se Sign Height (feet -inches) 1 t' ip t' t� - i41 Height of the sign structure may not exceed the height of the tallest building on the premises, except for sites over 85 acres, the height may exceed the tallest building but shall not exceed 115 feet. Height of Tallest Structure on the premise where the grand monument sign will be located? �S er 1AP. Pr Distance from closet edge of sign to property lines (in feet) CO E`R, -jo FT peoporric LA tit" 61f .. `I p,r. TO pt2Ai etl lAl-)>� The sign must be setback from the side and rear property lines of the premise a distance equal to the height increase requested or five feet, whichever is greater. The minimum front setback is the smaller of the front yard required in the zoning district or the height increase requested. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code)\Freestanding Sign-updated.doc Section 3- Reface and Copy Change of Existing Freestanding Signs When the current sign code became effective on August 24, 2010, the City strived to create a sign code that would reduce the impact to property owners and businesses that had existing freestanding signs on their property. The city permits refaces and copy changes to existing freestanding signs under several different scenarios: 1. A freestanding sign that conforms to the current sign code is permitted refaces and copy changes with a permit. 2. A freestanding sign that is not considered a freeway interchange sign, which was legally installed under the previous sign code but does not meet the current Sign Code,is per mitted to have refaces and copy changes for up to TEN years from the effective date of the City's Sign Code (8/24/10). A permit is required for any reface or copy change. Please note, modifying the sign height, increasing the sign area, or relocating the sign is not permitted without bringing the sign into full conformance with the City's Sign Code. At the end of the ten year period the sign may remain as -is indefinitely, however additional refaces or copy changes will require that the sign be brought into conformance with the Sign Code. 3. A freestanding sign that is considered a freeway interchange sign and was legally installed under the previous sign code is permitted to have refaces and copy changes for up to FIVE years from the effective date of the City's Sign Code (8/24/10). A permit is required for any reface or copy change. Please note, modifying the sign height, increasing the sign area, or relocating the sign is not permitted. At the end of the five year period the sign may remain as -is indefinitely, however any changes to the face or structure of the sign will require that the sign be removed. 4. Freestanding signs that did not comply with the City's previous sign code, for example those that were installed while an area was in King County, are not permitted to have any changes to the face or structure of the sign without bringing the sign into conformance with the Sign Code. Staff can help you research previous permit history to determine if your existing freestanding sign was installed under the provisions of the City's previous Sign Code. You will note that under Section 1 of this sign permit application additional signs are allowed for premises with over 800 feet of linear street frontage or for corner properties. Even if your property qualifies for this additional signage under Section 1 you will not be able to install it until any existing non -conforming sign(s) are removed (TMC 19.36.070). Table 4, Existing Freestanding Sign Details Existing Freestanding Sign 1 Existing Freestanding Sign 2 Notes: Date of last sign permit issued by the City for sign that is being modified: Existing Sign Area: Proposed Sign Area: Sign Height (feet - inches): Distance from closet edge of sign to property lines (in feet): Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\ 2011 SIGNS (New Sign Code)\Freestanding Sign-updated.doc INSPECTIONS A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. The issuance of some signage within the City may require a permit from the Washington State Department of Transportation (WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code)\Freestanding Sign-updated.doc City/State Name: 3 1/2" Cap Ht. Amtrak Contact Information and Than You Message: 2 5/16" Cap Ht. RECEIVED AUG 14 2013 1 '1 PizAforita Signag'} 'Ifi 111' Station Informatio H' 1'14 Display Case' II I '111 I 1• All Sign Type 1111 '' I, I 1, II I 1 1 1: 1111,1111 11 li 'e Sign Size and Layout •;;i Layout ;•;;;; n; The Station Information,, ! p11 I Display Case has a I • :•„ ',I customized layout. 11,, .',1 1, Graphic Components',.,;. !1 pl 1 P Logo Curve: 7'-1/2" Wide x 1'-5" HigI:11'' is II v•• lit .III I. •I,I l • E.,' II'I'' 1 • ` .:I Il I. 1• 1 l ' i1 1• 11 1i1., I. I 11, ! y I II' I 1.'! ! 1 III •+ 1 '�1'[ 1t Sa ri, GC)Mh/IIjN1 I 1 P1 `' ! 1` I ,', : I •�� ; "p,�0 5�p B' DI —VI LOI'ME.N ( ,fl iI I. II• 1 'l,ll •. I .111 i II ' : y f , I 'I 1 11 ,. • March 2090 ''HI A Itrlak Gratthil' Siignage Standards fiKanual© ,, +I ' I I.I, I Il; I �. 1, i : r + , • I •t II I' I •t i1 1 'I , ' LANN � INd AsPPF/ON• D; f • I ` ciGh6nocetbe'n4.tblhesq alahs itOua P'roa,1frpinithe ` , 'itI an Ivion of D /'- I I i II jl , I + II .1 r I;I 1 II +- I Itl I I I 1 I I I I 1 1 1 I 1 I t • 1 1 :.J .I I ' ,I I. • 11 II • , 1 r I I. I , o , •I1 -II 1 1 1 I I , t •.1 I I I j`II 1.+1 i ,' . I + I I I 1' k !jip if. • jl r 1 r A .II 1 1 11. 1 1 Finishes 1) Logo curve painted AMT Blue* 2) Amtrak logo painted White* 3) Posts, panels, and bases painted Silver* 4) Frutiger 65 Bold text painted AMT Blue* 5) WSM model TN36 (2130 x 1052 x 60mm) triple sash top -hinged lockable, tamper -proof, weatherproof cabinet 6) Tack surface 7) Changeable information (approved contents and display format from Amtrak Signage Brand Management) 8) Entire sign clear coated* 0 CD AMTRAK 4.23 Anniston, AL - ,---:,<--,,--- ,,,/,.:.-;--- 1-800-USA-RAIL Amtrak.corw 0 All Sign Type, Side A RECEIVED AUG 14 2013 Cc)mt\AO I I Y p�V�LUI'mi. NT Approved y! Date:1 O PLANMNO. APPROVED No change: can be madeto these plans without approval from the Planning Diyisi9n of CD Ibled(Af Platform Signage Station Information Display Case All Sign Type Design Intent Drawing • Paint • Matthews Acrylic Polyurethane Low Volatile Organic Compound (LVOC) specifications provided. • AMT Blue Satin VOC# SVOC1142SP • Silver Satin VOC# MP18073 • White Satin VOC# SV202SP • Clear Coat VOC Satin Clear #281228 For additional infor- mation on Sign Type All contact Amtrak Signage Brand Management. FXNheor 23 Sit 4)(1°L Amtrak Graphic Signage Standards Manual® • March 2010 SEAT WALL TRENCH DRAIN SEE TK-DD.08 #4 REBAR, 12" O.C. (BOTH WAYS) TOP AND BOTTOM KEY TO FOOTING SEAT WALL FG EMBANKMENT 12" ii 12„ 24' #4 REBAR, 12" O.C. 3/4" CHAMFER ON ALL (4) SIDES 2 BASE OF WALL FG WALKWAY COMPACTED STRUCTURAL FILL (6" MIN) 7 SCALE: NTS TK-CP.04, TK-CP.051K- CP.06, 1K-CX.02 ARSE PST mmabo,I I "_ alJ its" RECEIVED AUG 1420131 • COMMUNI Y DEVLLOPMENT t ! changes .e.1 be made to these plans witl-mul approval from the Planning Division of DCD 8tkIbrr 2.2 512-09 Attachment B I /(J''f Lvc L ¶.21 10113111.111111.1"1.— Anniston, AL All Sign Type, Side A Freestanding on Custom Posts Thank you for choosing Amtrak. For more information: 1-800-USA-RAIL Amtrak.com All Sign Type, Side B Freestanding on Custom Posts Platform Signage Station Information Display Case All Sign Type Mounting Option The following Mounting Option provides a guide- line for the placement of Station Information Display Case. Comments • Sign placement is coor- dinated by Amtrak management. • One sign per unstaffed station. RECEIVED V4' latr DEC 202012 t`ar f;OMM11NI f Y UI.VELOI'MENT Amtrak Graphic Signage Standards Manual® ■ March 2010 2t-t7 .r ! r 1-4 YELLOW tzva4-1- kkAveie S,3 SF Front RED NFTj1RAL COLOR / LE FINISH MINUM - EL BRACKETS AL w/ WHITE SYMBOLS (0t40tr �v ityri OA.E s 4 -ek = 13.1 SC ETALLIC COPPER METALLIC SILVER (FINE) - POSTS r G" X I s Fr -sic-c- 7 S Sr s p `>ti 4_C �y�Qr METALLIC SILVER (FINE) 4N� JG CAST BASES Sign Type: A2.0 Overall Height: 14.1-1" 17 Overall Width Front View: 4' - 6 7/8" Overall Width Side View: 4' - 3 17/32" Weight: 434.5 lbs See Pages PD-1.5 — PD-1.7 for Construction Details See Pages PD-1.9 or PD-2.2 for Optional 3- or 4-Disk Fin See Pages LT-2 for Template Layouts and Colors Transit "T" and symbols to be provided as Artwork by Sound Transit It — for J t- AkeS51465 8.6 SF 1trt c_ v tesS i P t2 i4 2:3 SF lope S I D E S tbI- 1\12,cA 3©. S SF Side SYSTEM -WIDE SIGNAGE Design Manual SOUNDTRANSIT Sign Elevations STATION IDENTIFICATION A2.0 Transit Beacon, Minor aihBtr 31 Not For Construction Not To Scale Sound 'Transit management assumes responsibility for all sign symbols, messages and content within the system. D.,une4 Iwo Twelve Natalawa 1,c • %Iran Design Inc • Ion Bent D& n Sotnti Transit 1ADd 0ntna STRUCTURAL ELEMENTS Cast Parts / Bases ILARGE BASE (CD-9) SIGN TYPE: A- AND B-SERIES RECEIVED OS 20 I); Vf .LUI<MLt'.0 SMALL BASE (CD-99) SIGN TYPE: H-SERIES SMALL POST BASEPLATE (CD-36) SIGN TYPE: T-, E- AND F-SERIES IBOLT CAPS ALL SIGNS TYPES USING BASES SHOWN ABOVE SYSTEM -WIDE SIGNAGE Design Manual SOUNDTRANSIT Design Standards STRUCTURAL ELEMENTS Cast Parts Bases Mititsr Not For Construction Deaglen iwn I. aatatawa Inc. • NaesUn O. AK • /On Bentz Design Saind Transit 2004 9l200< DS-39 4 • • 24" dia. s 5I44 040(0 2. P. 1'-41/4" dia. 7" 11/16" 11/16" • • Vertical Support 5" schedule 40 aluminum pipe into Base and secured with Set Screws, © Set Screws 1/2-13 x 3/4" stainless steel socket set screws secured with Lock-Tite. Large Base CD-9 (see CP3.0) O Cast aluminum base with four (4) slotted holes for anchors, paint Metallic Silver P8. Anchors Four (4) 3/4" dia. x 24" min. embed anchor bolts set with template Ce/LIc.s2 —rE t LANDSc.P%'tID -rev_ -PLF.0.3 s Rebar o.c. o 1ligiAties %0o% _ I' OVertical Section View / A1.0, A1.1, A2.0 & A2.1 Drilled Footing Scale: 1 1/2" = 11-0" RECEIVED DEC 202012 • 24" dia. • 7" 1'-41/4" dia. 11/16" OVertical Section View / A1.0 & Scale: 1 1/2" = 11-0" 11/16" Vertical Support 5" schedule 40 aluminum pipe into Base and secured with Set Screws Set Screws 1/2-13 x 3/4" stainless steel socket set screws secured with Lock-Tite. © Large Base CD-9 (see CP3.0) A Cast aluminum base with four (4) slotted holes for anchors, paint Metallic Silver P8. Anchors Four (4) 3/4" dia. x 9" min. embed anchor bolts set with template Rebar (3) #3 hoop ties @ 4" o.c. (6) #4 vertical ties A1.1 Second Pole Drilled Footing • 24" dia. Plan View / A1.0, A1.1, A2.0 & A2.1 Drilled Footing Scale: 1 1/2" = 1'-0" ERA•SIr 3.3 5 fF092' l SOUNDTRANSIT January 29, 2002 DATE A July 29, 2003 �2\ February 7, 2004 REVISIONS [ ] Approved ( ] Approved with changes noted CUSTOMER SIGNATURE DATE Sign Production Drawings A1.0, A1.1, A2.0 & A2.1 Drilled Foundation Detail FD-2.0 .: I T DEVL-LOPML-NT 1 • 2 • X 4 tO tl • 5 0 1 1 4/30/2013 PLANNING APPROVED-7' No changes can be made to these plans without approval from the Planning Di ision of D. D £ISNYtlf ISSUED FOR CONSTRUCTION Designed By. EP Drown By. DCH/DW Checked By. Approved By. DH F1.1 - 511 - 1/ GS2.01 wee RECEIVED AUG 14 2013 • COMMUNI 1 Y DEVELOPMENT SEE DWG TK-GS1.04 410 --- ---- ----- ---- --- - --- ---- - ---- --- - TRANSIT SIGNAGE PLAN 2 3 SCALE: 1 /16' = 1 0" Consulting Engineers Filth Avenue, Suite 1600 otlk, Wo*hinplon. 98101 06) 622-5822 Fox (206) 622-8130 Submitted: O. TIMPSON Dale. 4/30/2013 TK-A1.01 THIS SHEET IS FOR REFERENCE ONLY - NOT PART OF CONTRACT HEWITT Approved: .1, O'HARE Lr SOUNDTRANSIT Dotes 4/30/2013 Stale: 1 /16"= r-0" tr Filename: TK-GS 102.DWG Controcl No,: CN0143- 12 Dote. 11/9/2012 KEY PLAN SET NOTES 1. FOR LOCATION OF LIGHT POLES SEE ELECTRICAL FOR LOCATION OF SIGN POLES, SEE CIVIL SIGNAGE PLANS & STATIONING 2. SEE SHEET GS0.01 FOR GENERAL NOTES. 3. FOR REGULATOR AND OTHER SIGNS, SEE SHEETS TK-CM.01-TKCM.06 AND TK-A11.12. 5 /z449 1 4 0 6 1s SCALE IN FEET Z SOUND TRANSIT TUKWILA STATION TUKW I LA, WASH I NGTON TRANSIT SIGNAGE PLAN 2 Orowing No.: TK-GS I.02 Sheet No.: Rev.: 237 0 No. Date By Chk. App. Revisions 'Cif► Witty rovs YELLOW 1 BRIGHT BLUE — RED NATURAL COLOR / T B E FINISH ALUMINUM - NEL BRACKETS rE L wl WHITE SYMBOLS -rota roesc2f-J area ' $ •'1 Sv M: ILIC COPPER Sign Type A1.O Overall Height: Overall Width: Posts Center t . Center: Weight: See Pages PD- See Pages PD- See Pages LT-1 Transit "T" an w 12' - 8 1/4" 8'-11" 642.5 Ibs .0 — PD-1.4 for Construction Details .9 or PD-2.2 for Optional 3- or 4-Disk Fin for Template Layouts and Colors symbols to be provided as Artwork by Sound Transit • ace"34 k r-- v x6 ` r. .$ 1 Iistt Itiv6 5.0 METALLIC SILVER (FINE) - POSTS )11 sr-e` Tacoma Dome Station METALLIC COPPER — METALLIC SILVER (FINE) CAST BASES W.1M441;&11S4 1* $4C1° oven: Iwo hvebe Haiatawa Inc • MaestriDesigni • Ion kin i D.sn 4 v, 1 IN36* SS RED METALLIC SILVER (FINE) CAST CUFFS le 46\ * WM annr+ 1004 SYSTEM -WIDE SIGNAGE Design Manual lir SOUNDTRANSIT Sign Elevations STATION IDENTIFICATION Al.0 Transit Beacon, Major Not For Construction Not To Scale Souris! Transit management assumes responsibility far all sign symbols, messages and content within the system. 0/1004 PLANNING APPROVED CV 24" dia. 1'-4 1/4" dia. 7" 11/16" 5 5/8" ID 1 11/16" F5.563" Vertical Support 5" schedule 40 aluminum pipe into Base and secured with Set Screws, Set Screws 1/2-13 x 3/4" stainless steel socket set screws secured with Lock-Tite. Large Base CD-9 (see CP3.0) Cast aluminum base with four (4) slotted holes for anchors, paint Metallic Silver P8. Anchors Four (4) 3/4" dia. x 24" min. embed anchor bolts set with template 0 Rebar (3) #3 hoop ties @ 4" o.c. (6) #4 vertical ties OVertical Section View / A1.0, A1.1, A2.0 & A2.1 Drilled Footing Scale: 1 1/2" = 1'-0" CV 1-- ;- 24" dia. Vertical Support 5" schedule 40 aluminum pipe into Base and secured with Set Screws Set Screws 1/2-13 x 3/4" stainless steel socket set screws secured with Lock-Tite. Q Large Base CD-9 (see CP3.0) A Cast aluminum base with four (4) slotted holes for anchors, paint Metallic Silver P8. Anchors Four (4) 3/4" dia. x 9" min. embed anchor bolts set with template t 'i1fr Rebar (3) #3 hoop ties @ 4" o.c. (6) #4 vertical ties -`:*1Vertical Section View / A1.0 & A1.1 Second Pole Drilled Footing Scale: 1 1/2" = 1'-0" 24" dia. 7" 11/16" L 5 5/8" ID Plan View / A1.0, A1.1, A2.0 & A2.1 Drilled Footing Scale: 1 1/2" = 1'-0" PLANNING APPROVED • No changes can be madeto these plans without approval from the Planning Division of D D Approved pp o Y: Date: SOUNDTRANSIT January 29, 2002 DATE / \ July 29, 2003 February 7, 2004 REVISIONS [ ] Approved [ ] Approved with changes noted CUSTOMER SIGNATURE DATE o -z > N 11 0 C SignE' �` Cs Production Drawings A1.0, A1.1, A2.0 & A2.1 Drilled Foundation Detail