Loading...
HomeMy WebLinkAboutPermit S12-069 - PANDA EXPRESS - BUILDING MOUNTED SIGNPANDA EXPRESS 17100 SOUTHCENTER PKWY S12-069 1 BLDG MOUNTED SIGN City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PERMANENT SIGN PERMIT Wall or Awning Face Sign Parcel No.: 7888920020 Permit Number: S12-069 Address: 17100 SOUTHCENTER PY TUKW Issue Date: 09/28/2012 Suite No: Permit Expires On: 03/27/2013 Business: PANDA EXPRESS Property Owner: Name: WIG PROPERTIES LLC-SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: TONY LE Address: Phone: 206-696-1162 Contractor: Name: CRIST SIGN Phone: Address: DESCRIPTION OF WORK: REMOVE WALL MOUNTED SIGN ON NORTH SIDE OF BLDG (WIG BLVD SIDE). LARGER CIRCLE SIGN"PANDA EXPRESS" SIGN WILL GO UP ON FACE OF BLDG, ABOVE MAIN ENTERANCE. MASTER SIGN ALLOWS UP TO 6% OF TOTAL WALL AREA 884 SQF WALL AREA, INCLUDING DOOR, SIGN IS 38.49 SOFT ELECTRICAL WILL BE REQUIRED. Fees Collected: $222.00 Zoning: TUC Sign Type: Electricity Provided by: PUGET SOUND ENERGY WALL SIGN: Total exposed building face: Permitted sign area: Area of sign: AWNING FACE SIGN: Area of awning: Sign area: Type of lighting: Type of material of awning: Type of material of sign: INCENTIVE WALL SIGNAGE: Location of Entrance: Total Exposed Building Face: Area of Wall: Method of Lighting: Wall Sign #1 884 square feet 53.04 square feet 38.49 square feet Awning Sign #1 0 square feet 0 square feet Wall Sign #2 0 square feet 0 square feet 0 square feet Awning Sign #2 0 square feet Awning Sign #3 0 square feet rinr WAI 1 _AWN S12-069 Printed: 09-28-2012 Planning Division Authorized Signature: 7 Date: c( u lL I hereby certify that I have read and examine . this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wi. , w ether specified herein or not. Date: THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. To schedule a final inspection for your sign, please call the inspection request line at 206-431-2451. Enter Inspection Code 1510 for sign final inspection. Please allow up to 5 business days for your inspection. FINAL INSPECTION APPROVAL: DATE: doc: WALL -AWN S12-069 Printed: 09-28-2012 SIGN INSPECTION (PLANNING) File No. S12-069 Name of Tenant: Panda Express Sign Address: 17100 Southcenter Pkwy. Date Photo Taken: 11/4/2015 X Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Signappears to conform to approved permit. AS Contractors or Tradespeople Print-riendly Page Page 1 of 1 Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company CRIST SIGN SERVICE 2062507446 Po Box 33178 Seattle WA 98133 King Individual UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601746949 Active CRISTSS923KB Electrical Contractor 5/2/2008 5/5/2014 Sign Unused Electrical Administrator INFORMATION License CHRISJ'927K0 Name CHRIST, JEFF Status Active Business Owner Information Name Role Effective Date Expiration Date CHRIST, JEFF E Owner 05/02/2008 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 TRAVELERS CASE SURETY CO 105268642 04/30/2009 Until Cancelled $4,000.0004/30/2009 1 GREAT AMERICAN INS. CO. 3602801 04/15/2008 Until Cancelled 04/30/2009 $4,000.0005/02/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EJONV02651 6/1/2012 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 09/25/2012 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: signpermits@TukwilaWa.gov PERMANENT c jIVED BUILDING MOUNTED SIGNSEP 2 5 GOMMUNfTY DEVELOPMENT PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Permits PIusTyperP-SIBLDG Planner: )L C File N umber. Cj ' ,D — Needs Electrical: Yes/No AssodatedleNumber Fs 4 Pam(& I/ (00 Ste, � - Prk.tn Business Name Address of Sign Phone t t222( =f-r.eAtm • Sla t (2D6)so-71,1q (o Applicant/Contact Address, City, State, Zip Phone ( csT �' f aZZ6 _ ,19$1) 'Ate . (ZG16)7q Co actor Address, City, State, Zip Phone I HEREBY CERTIFY that the information contained in this application and the materials famished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct, it could delay issuance of a permit or, if the permit has been is ued, be cause for the City to - voke the sign pennit. D il5/6Z e - or Auth..• - d Agent Email The City will send any official notices, letters, — i other official notices via email. If you wish to receive all official communications from the City via US Postal Mail, check here: ❑ ?L%-67'6-#67_ eattra‘-eri 21Y - 1 CHECKLIST Completed and signed application (this form). Three copies of a dimensioned and scaled site plan showing property lines, streets, buildings and parking areas; the location of all existing building mounted signs on the same building as the proposed signs. -6- Three copies of scaled and dimensioned drawings of the proposed sign or signs with area calculations. o Three copies of a scaled elevation of the building walls where the signs will be located indicating the location and dimensions of the exposed building face used to calculate the sign area. 9✓Three copies of a scaled and dimensioned building profile, if projecting signs are proposed. cr.-Method of illumination, if proposed. Method of support and attachment for building - mounted signs. Structural calculations if the sign weighs over 400 pounds. 'tY Application fee listed in current fee schedule. .el One copy of a valid Washington State Contractor's license or owner's affidavit. O Valid Tukwila business license number for the sign contractor, if applicable: TOTAL NUMBER OF SIGNS Total number of signs included in this application: Section 1 Section 3 Section 2 Section 4 u-'sI- 40( Ili 62it Clu I$ er N ®' GR LsPss dI 2 3 ic$ ils Pi/ r-116; Q:\ Department Folders\ DCD\ DCD Common\ Applications -Handouts, Land Use\ 2011 WEBSTE-OCT 2011\ 2011 SGNS(New Sgn Code)\ Building Mounted Sgn-May2011.doc Building Mounted Signage Worksheet The City's sign code permits a variety of building mounted signs, including wall signs, signs on awnings, canopy signs and projecting signs. This sign permit application can be used to determine the total number of building mounted signs permitted for your business. The application also provides the specific code standards for the common types of building mounted signs, see TMC 19 Sign Code for details. Please note that you may not qualify for all signage types outlined in this application. Section 1- Wall or Awning Face Sign Each public entrance is eligible for either a flush mounted wall sign or an awning face sign. In some cases an additional wall sign maybe permitted on walls that do not have entrances, see Section 2 of this application. Use the table below to determine the maximum permitted size' of your wall sign: Maximum Sign Area AREA (LxH) of Exposed Building Face (EBF) in square feet Permitted Sign Area 0-500 EBF x.05 or 20 square feet, whichever is larger 501-1,500 (EBF-500) x .04 + 25 square feet 1501-3,000 (EBF-1,500) x .03+ 65 square feet 3,001-5,000 (EBF-3,000) x .02+ 110 square feet Over 5,000 150 square feet maximum Wall Sign Worksheet ?AA Sign l Sign Reserved for City Use F more detail see the Sign Code Language, MC 19.20.050 A. Wall Area t 1 v`liali The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area (�Q n'.. 1 l /� )� G Calculate the maximum sign area allowed for the wall from the table above. Proposed Area of Sign 1 Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy a List what the sign will say (for example name of business). Awning Face Sign Worksheet Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 B. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see TMC 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the wall from the table above. Area of Awning Face The size of an awning face sign is limited to the area from the table above or 30% of the area of the face of the awning, whichever is smaller. Proposed Area of Sign Calculate the area by drawing one box around the entire sign copy using 90 degree angles. Lighting Type Only indirect lighting maybe used for awning face signs. Awning Material In commercial zones awnings may only be made of canvas or nylon fabric. Sign Material Signs may only be vinyl or paint applied directly to the awning. Sign Copy List what the sign will say (for example name of business). This table is inapplicable if your site is covered under an approved Master Sign Program and an increase in sign area was granted. Q:\ Department Folders\ DCD\ DCD Common \ Applications -Handouts, Land Use\ 2011 WEB9TE-OCT 2011\ 2011 9GNS(New 9gn Code)\ Building Mounted 9gn-May2011.doc Section 2- Incentive Signage Wall signs may also be installed on walls that do not have public entrances if the wall where the sign will be located meets at least one of the following design criteria: 1. At least 50 percent of the wall area between the height of 2 and 7 feet must be transparent with either an unobstructed view into the business or use or a display window with a depth of at least three feet. 2. Architectural detailing consistent with the building design using changes in color, materials, texture, and variations in the wall plane. 3. Artwork such as mosaic, mural or sculptural relief covers at least 50 percent of the wall surface. If the artwork uses words or images related to the business on site they will be considered part of the sign area. 4. One or more trellises covering at least 50 percent of the wall area between the height of two and seven feet, planted with climbing vines and other plant materials in a planting bed at least two feet in width and provided with permanent irrigation. Signs permitted under this Section may be up to 50 percent of the area calculated in the Table in Section 1. Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 F 4. Wall Area The size of the sign is based on the area of the wall fronting the tenant space where the sign will be located, see 19.08.110. Maximum Sign Area Calculate the maximum sign area allowed for the wall from the Table in Section 1 and reduce by half. Proposed Area of Sign Calculate the area by drawing one box around the entire sign face or copy using 90 degree angles. Sign Copy List what the sign will say (for example name of business). Section 3- Projecting and CanopvEdge Signs One Projecting or Canopy Edge Sign may be permitted per business in addition to those signs permitted in Section 1 and Section 2. In order to qualify for a sign under this section the business utilizing the projecting or canopy edge sign must have a direct ground floor public entrance and the sign must overhang a sidewalk or walkway. The sign is not permitted to overhang parking areas, service areas or other non -pedestrian oriented areas. Not all buildings will qualify for a projecting or canopy edge sign. Projecting Sign Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 C. Proposed Area of Sign Maximum area permitted is 20 square feet per face and 40 square feet total for all faces. Distance Sign Extends from Building The sign may not stick out more than four feet from the building wall. Also, the sign can't extend further than the sidewalk it overhangs. Height above ground The bottom edge of the sign must be at least eight feet above the sidewalk or walkway that it overhangs. Rotating Display Proposed Mechanical rotating displays are permitted. Sign Copy List what the sign will say (for example name of business). Canopy Edge Sign Canopy edge signs are limited to a single row of individual letters which are not permitted to extend beyond the edge of the canopy on which the sign is located. The canopy must be located over a public entrance. Sign Reserved for City Use For more detail see the Sign Code Language, TMC 19.20.050 E. Height of letters Maximum height allowed is 12 inches Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code)\Building Mounted Sign-May2011.doc Length of Canopy The sign length is limited to 2/3 of the length of the canopy. Length of Sign Proposed Lighting The letters may be lit, specify whether and how this is proposed. Sign Copy List what the sign will say (for example name of business). Section 4- Pedestrian Oriented (Building Mounted Signage In order to encourage a more pedestrian oriented environment, the City allows the following signs in addition to those listed in sections 1, 2 and 3 of this application. Permits are only required for signs listed under this section if the signs will be discernable from any public right of way, a neighboring site or an off -site business. Not all businesses will qualify for signage under this section. Under-Awning/Canopy Signs In order to qualify for under-awning/canopy signs an entrance to a business must be provided from a public or private sidewalk. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(1). Number of signs? If located on multiple walls, list wall location. Only one permitted per business per wall. Area of sign? No sign shall exceed three square feet in area. Depth of awning or canopy? No sign may project farther from the building than its associated awning or canopy. Distance of sign from wall? Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. Awning/Canopy Side Sign In order to qualify for an awning/canopy side sign, the awning or canopy must be located above a public entrance. Also, the sign is not permitted to project beyond the edge of the awning or canopy in which the sign is located on. Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(2). Number of signs? If located on multiple walls, list wall location. Only one sign permitted per business per wall. Area of awning or canopy side? Area of sign? Sign may not exceed 40 square feet of awning or canopy side area (Row @). Height of text and/or graphics? May not exceed a height of 12 inches. Distance from ground to bottom of sign? The lowest edge of the sign must be at least eight feet above the ground. If an awning is being used, material of awning? Awning signs may only be made of vinyl or paint applied directly to the awning. Permanent Window Signs Permanent window signs are only permitted if the following conditions are met: 1. The signs will be placed in a ground floor window that provides direct line of sight into the public area of the business. Note: Permanent window signs are not permitted in windows located along private offices, storage space, display windows or windows that are opaque or otherwise do not allow viewing into the business. 2. The placement of the permanent window signs is on the same wall as the public entrance for the business. Permanent Window Signs Applicant's Response Reserved for Use by City Staff. Applicable Code Language, TMC 19.20.050 (F)(3). Area of window? Q:\Department Folders\DCD\DCD Common \ Applications -Handouts, Land Use\2011 WEBSITE-OCT 2011\2011 SIGNS (New Sign Code)\Building Mounted Sign-May2011.doc Total Area of signs? No more than ten percent of the total ground floor transparent window area along the exposed building face of a business may be occupied by permanent window signs. Spandrel, opaque and mirrored glass do not qualify for window signage. No individual sign may be larger than six square feet. In no case shall the total sign area in the window, including both permanent window signs and temporary window signs, exceed 25 percent of the window area. Height of Letters and text? No window sign shall have a height greater than eight inches. Proposed Materials? The signs may be made of gold or silver leaf, vinyl or paint, applied directly to the glass; etched into the glass, neon mounted or suspended behind the glass; or framed and mounted paper signs. Method of illumination? Signs may only utilize neon tubing. INSPECTIONS A final inspection of the sign is required for all signs when installation is complete. The applicant or installer is required to schedule the final Sign inspection through the City's Inspection line at (206)431-2451. The 4-digit inspection code needed for scheduling the final Sign inspection is 1510. The applicant or installer does not need to be present for the final Sign inspection It is the responsibility of the installer to obtain the electrical permit and inspections from the City of Tukwila Permit Center at (206) 431-3670. The electrical inspector will need access to complete the Electrical portion of the inspection. GE.VERAL The issuance of some signage within the City may require a permit from the Washington State Department of Transportation (WSDOT). It is the applicant's responsibility to obtain all required permits from the appropriate government agency. For information on permits that may be required from WSDOT call (360) 705-7296. The issuance of a sign permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the City. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the City shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Director from requiring correction of errors in the construction documents and other data (TMC 19.12.020 (C)). Pursuant to TMC 19.12.0150, sign permits shall be valid for 180 days from the date of issuance of the sign permit. The Director may approve one extension of up to 30 days if a written request is submitted to the City BEFORE expiration of the 180 day period. Q:\Department Folders\DCD\DCD Common\Applications-Handouts, Land Use\2011 WEBSITE-OCr 2011\2011 SIGNS (New Sign Code) \ Building Mounted Sign-May2011.doc Sign A Proposed 84" Top To Grade Front Elevation Height 84" ±24'-3" Allowed SF per code Width 84" Bottom to Grade Area 49.0 ±17'-3" Panda Express 1649-17100 South Center Parkway Tukwila, WA 98188 April, 2012 1z n ger,fOate. 8/ 19J2011 (Sign A) ✓4ra a ^..-21-! !",,; .`'7 ,i,1i1 1tti11i;;�ttitTti .Platinum r Inspa rJamba Juice Verizont;, ijele_ss, • ©2012 Google 9g ,t, I'it 65835.N 122`1542.85' W eev 2F � E f11111ot."�.it t1*1 Ir1 !1i Ali; Th` ,0,1d Spaghetti Factory ii...i E.1+ .1,4 1. a s M rik,le f3ivd ;11111'11.11111Ni W1111111'1j- 11111 • • rigegooNIMII.016110110101.1111- 11- 1-11....111111170,1, figf MET CO 1ANDA EXPRESS Client Review Status Notes Allen Industries, Inc. requires that {.] Approved" drawing be obtained from the client prior to any production release or production release revisluii. DApproved ❑Approved as Noted 0 Revise 8&ubmit Name Title Date Date / Description 04/09/12 Issue Date 04/18/12 A BH 08/22/12 /2\ BH Project Information Client Panda Express 1649-17100 South Center Parkway Tukwila, WA 98188 File PANDA.090 A - Sales CB Design DEIBH/WAPM AR This is an original unpublished drawing, created by Allen Industries, Inc. It is submitted for your personal use in connection with the project being planned for you by Allen Industries, Inc. It is not to be shown to anyone outside your organization, nor used, reproduced, copied or exhibited in any fashion whatsoever. All or part of this design (except for registered trademarks) remain the property of Allen Industries, Inc. p- SITE PLAN Alien Industries /Corporate Identity Programs Architectural Signage Division 4100 Sheraton Court, Greensboro, NC 27410 Phone 888-294-2007 Fax 336-294-4333 Because Image Is Everything„ ELEVATION Q w w w CNtet w CJ 1 Sign A Proposed 84" Top To Grade Front Elevation Height 84" ±24'-3" Allowed SF per code Width 84" Bottom to Grade Area 49.0 ±17'-3" 26'-0" ± IIIIIIl1! IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII Hong 11111111111 III— —==�-� _ �_== 1 ' i�i� ��"ice_ WEST ELEVATION SCALE: 1/16"= 1-0" Client Review Status Notes Allen Industries, Inc. requires that ate] Approved" drawing be obtained from the client prior to any production release or production release revision. ❑Approved ❑Approved as Noted 0 Revise &submit Name Title Date Date / Description 04/09/12 Issue Date 04/18/12 A BH 08/22/12 h\ BH Project Information Client Panda Express 1649-17100 South Center Parkway Tukwila, WA 98188 File PANDA.090 /a - Sales CB Design DE/BH/WAPM AR This is an original unpublished drawing, created by Allen Industries, Inc. It is submitted for your personal use in connection with the project being planned for you by Allen Industries, Inc. It is not to be shown to anyone outside your organization, nor used, reproduced, copied or exhibited in any fashion whatsoever. All or part of this design (except for registered trademarks) remain the property of Allen Industries, Inc. Alien Industries 'Corporate Identity Programs Architectural Signage Division 4100 Sheraton Court, Greensboro, NC 27410 Phone 888-294-2007 Fax 336-294-4333 Because Image Is Everything tLtVA I IVIN REMOVE EXISTING .......... EXISTING PROPOSED PANDA EXPRESS Allen Industries, Inc. requires that £ ] Approved" drawing be obtained from the client prior to any production release or production release revision. ❑Approved DApproved as Noted 0 Revise &€submit Name Title Date 04/09/12 Issue Date 04/18/12 /t\ BH 08/22/12 /2\ BH A- A - Client Panda Express 1649-17100 South Center Parkway Tukwila, WA 98188 File PANDA.090 Sales CB Design DE/BH/WAPM AR This is an original unpublished drawing, created by Allen Industries, Inc. It is submitted for your personal use in connection with the project being planned for you by Allen Industries, Inc. It is not to be shown to anyone outside your organization, nor used, reproduced, copied or exhibited in any fashion whatsoever. All or part of this design (except for registered trademarks) remain the property of Allen Industries, Inc. /en Industries "Corporate Identity Programs-�� Architectural Signage Division 4100 Sheraton Court, Greensboro, NC 27410 Phone 888-294-2007 Fax 336-294-4333 Because linage Is Everything - r --U-- WKMtu rHLt LUUU c' a2 W. an CV 2a LJ w 8� IX t 0 LEVEL LINE - 7'-0" Hen Industries FILE NUMBER: E1820 FACE MATERIAL SPEC MANUFACTURER: SABIC SIZE/THICKNESS: 177' SG POLYCARBONATE COLOR: CLEAR FINISH: SATIN NOTES: 1° EMBOSSED FACE FOR INCREASED STRUCTURAL RIGIDITY C 7'-0° FORMED FACE LOGO SCALE: 1/2"= 1'-0" us ELECTRIC SIGN FACE/GRAPHIC SPEC FORMED FROM FACE MATERIAL SIZE/THICKNESS:1 1/2" COLOR: CLEAR NOTES: SECOND SURFACE DECORATED TRANSLUCENT IN PROJECT COLORS. LED LAYOUT OA SQ FT: 49 TOTAL SQ FT: 38.49 THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. THERMOFORMED RETURN FORMED FROM FACE MATERIAL SIZE/THICKNESS: 1 1/2' NOTES: 1-1/2"RETURN PROVIDES 1/2" PROJECTION OF FACE FOR INSTALL, ENSURING PROPER 3 1/2" INSTALLED DEPTH RETURN MATERIAL SPEC MANUFACTURER: ROBERT & SONS (OR EQUAL) ALUM. COIL SIZE/THICKNESS: 3" X .040" COLOR: HUNTER RED FINISH: PREFINISHED NOTES: INTERIOR PAINTED ULTRA WHITE (MIN 85 BRIGHTNESS); BAFFLED DRAIN HOLES Misr GROUNDED ELECTRICAL CONNECTIONS BACKING MATERIAL SPEC MATERIAL: ALUMINUM SIZE/THICKNESS: 0.063" COLOR: ULTRA WHITE FINISH: GLOSS NOTES: MIN. 85 BRIGHTNESS 1 11/" Formed Face .177" Thk. Clear Polycarbonate Faces Rubber- Gasket FRAMING MATERIAL SPEC ILLUMINATION MATERIAL SPEC TRANSFORMER MATERIAL SPEC MATERIAL: ALUMINUM MANUFACTURER: AA LED MANUFACTURER: AA LED OR SIMILAR SIZE/THICKNESS: 1" x 1" x .125" MODEL: LS-0766HDCW UL APPROVED LED DRIVER COLOR: NONE COLOR: Cold White MODEL: 60W 12V FINISH: NONE LENGTH: 252 MODULES 83.2' NOTES: NOTES: NOTES: TOTAL NO. TRANSFORMERS: WELD TO RETURNS VERSION 2; 4 YEARS PARTS & (4) 60W LABOR WARRANTY UL APPROVED DRIVER WITH PANDA EXPRESS Allen Industries, Inc. requires that .1 Approved" drawing be obtained from the client prior to any production release or production release revislun. ❑Approved ❑Approved as Noted ❑ Revise &submit Name Title Date 04/09/12 Issue Date 04/18/12 A BH 08/22/12 /2\ BH A - Client Panda Express 1649-17100 South Center Parkway Tukwila, WA 98188 File PANDA.090 Sales CB Design DE/BH/WAPM AR This is an original unpublished drawing, created by Allen Industries, Inc. It is submitted for your personal use in connection with the project being planned for you by Allen Industries, Inc. It is not to be shown to anyone outside your organization, nor used, reproduced, copied or exhibited in any fashion whatsoever. All or part of this design (except for registered trademarks) remain the property of Allen Industries, Inc. ,.040" Aluminum Letter Returns '--Aluminum Riv-nut / -1 1/2" Pan -head Machine Screws / w/ Washer, Painted to match Letter Return Color 3.5" — 0 STANDARD FLUSH MOUNT ATTACHMENT SPEC SCREWS: 3/8" ALL THREAD WITH 3/8" RIVET NUTS WEIGHT: X 1 4/len Industries 'Corporate Identity Programs Architectural Signage Division 4100 Sheraton Court, Greensboro, NC 27410 Phone 888-294-2007 Fax 336-294-4333 Because Image Is Everything