Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG15-0031 - SEATTLE GOURMET FOODS - NATURAL GAS PIPING
SEATTLE GOURMET FOODS 18200 SEGALE PARK B DR FXPIRED 11129115 PG15-0031 City of Tukwila Department of Community Development * 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 3523049119 Permit Number: PG15-0031 Address: 18200 SEGALE PARK B DR Issue Date: 4/14/2015 Permit Expires On: 10/11/2015 Project Name: SEATTLE GOURMET FOODS Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028, TUKWILA, WA, 98138 Contact Person: Name: HEATH HAMBLEN Address: 4102 B PLACE NW, AUBURN, WA, 98001 Contractor: Name: UNIVERSAL REFRIGERATION INC Address: 4102 "B" PL NW, AUBURN, WA, 98001 License No: UNIVER1159RF Lender: Name: Phone: (253) 939-5501 Phone: (253) 939-5501 Expiration Date: Address: , , , DESCRIPTION OF WORK: IINSTALL NATURAL GAS PIPING FOR OWNER SUPPLIER GAS FIRED EQUIPMENT. Valuation of Work: $24,312.00 Fees Collected: $366.88 Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 National Electrical Code: 2012 WA Cities Electrical Code: 2012 WAC 296-46B: 2012 WA State Energy Code: 2012 2014 2014 2014 2012 w Permit Center Authorized Signature: ` Date: �""�� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature - e-�Date: Y1y1"1 s Print Name: Z-0 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND Building Use (per Int'l Building Code) Occupancy (per Int'I Building Code): Utility Purveyor: Water: CITY OF TUKWILA • Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httv://www.Tuk-wi]aWA.Jzov SITE LOCATION Site Ad Tenant Plumbing/Gas Permit No. Project No. Date Application Accepted: T Date Application Expires: use PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** PROPERTY OWNER Name: C 1 Addre O • $702 CitU�t (A 0 State: Zip: ` CONTACT PERSON — person receiving all project communication Name: Heath Hamblen Address: 4102 B Place NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email.. heath@universalrefrig.com King Co Assessor's Tax Suite Number: % Floor: New Tenant: [....Yes ❑..No PLUMBING CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B Place NW City: Aubum State: WA Zip: 98001 Phone: (253) 939-5501 Fax: -`(253) 939-5501 Contr Reg No.: UIpIIVERI 159RF Exp Date: 04/01 /201 Tukwila Business License No.: BUS-0993124 OD Valuation of Project (contractor's bid price): $ 2 3l2 . Scope of Work (please provide detailed information): 1�61kl OA6R4 �$ �,at16 &A, � 4t014&4 4;�'tb Sewer: 65as�.; �N �OA Otat� H:Wpplications\Forms-Applications On Line1201 I Applications\Ptumbing Permit Application Revised 8.9.11.docu Revised: August 2011 bh Pagel of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) • Each additional medical gas inlets/outlets greater than 5 Atmospberic-type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water cooler head Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective ' device other ftiq ' atrnaspheric- type vacuum breakers over 2 inch 51 mm diameter Gas piping outlets �(l Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific s Each lawn sprinkler system do any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. B A H ZED AGENT: r Signature: Date:1 D iS Print Name:4-41 L44060 Day Telephone: (253) 939-5501 Mailing Address: 4102 B Place NW Auburn WA 98001 City State Zip I H:\Applicatioris\Fo=-Applications On r ine\2011 ApplicationsTluntbing Permit Application Revised 8-9-1 l.dom Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK. ACCOUNTQUANTITY PAID $366.88 PG15-0031 Address: 18200 SEGALE=PARK B DR Apn: 3523049119 $366.88 GAS $366.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $261.00 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT:$366.88 R000.322.103.00.00 0.00 $73.38 Date Paid: Thursday, March 12, 2015 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 49252 Printed: Thursday, March 12, 2015 12:31 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit 1S-0031 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Projec : Type ;nspectl Address: Q Patl r 1 Date Called: Specialll_nstruction Date Wanted: a.m. Requester: v Qi Phone No: pnspector: "n , _ / I Date: $60.00 REINSPECTION FEE REQU rlor to inspection, fee must be paid at 6300 Southcenter Blvd., Sui a 100. Call to schedule reinspection. 1ES. INSPECTION RECORD Retain a copy with permit I P6 15-00 INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prs,gct: POO Typ of ns e tion, '14 43 I'LP9 -416 Address: I ?ap Pr � Date Called: special Instructfons.- — Date wanteT Requester'. Phone No, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 10/1/2015 HEATH HAMBLEN 4102 B PLACE NW AUBURN, WA 98001 RE: Permit No. PG15-0031 SEATTLE GOURMET FOODS 18200 SEGALE PARK DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/29/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/29/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fA 4 Rachelle Ripley2 Permit Technician File No: PG15-0031 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director March 24, 2015 HEATH HAMBLEN 4102 B PLACE NW AUBURN, WA 98001 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG15-0031 SEATTLE GOURMET FOODS - 18200 SEGALE PARK DR Dear HEATH HAMBLEN, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11xl7 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. Provide gas piping calculations in a matrix or table to show sizes of all pipes with lengths of each size of pipe specified, shall meet the total demand (CFH) of all gas fixtures supplied new and existing. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3670. Sincerely, Megan P n Permit Technician File No. PG15-0031 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0031 DATE: 03/30/15 PROJECT NAME: SEATTLE GOURMET FOODS SITE ADDRESS: 18200 SEGALE PARK B DR Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/31/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved a Corrections Required ❑ (corrections entered in Reviews) Notation: DATE: DUE DATE: 04/28/15 Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0031 DATE: 03/12/15 PROJECT NAME: SEATTLE GOURMET FOODS SITE ADDRESS: 18200 SEGALE PARK DR B X Original Plan Submittal Response to Correction Letter #, DEPARTMENTS: Revision # before Permit Issued Revision # after Permit Issued Building Division Fire Prevention ❑ Planning Division ❑ �Ns Nib Public Works Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/17/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/14/15 Approved ❑ Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED:��I (� Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials. 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hftp://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 03/30/2015 Response to Incomplete Letter # Response to Correction Letter # Plan Check/Permit Number: PG15-0031 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Seattle Gourmet Foods, Tukwila Facility Project Address: 18200 Seagle Pk Dr, Suite B, 98188 Contact Person: Heath Hamblen Phone Number: (253) 939-5501 Summary of Revision: A SEPARATE M-3 PAGE HAS BEEN ADDED TO THE PLAN SET. IT CONTAINS THE INDIVIDUAL APPLIANCES BY SECTION AND ALL THE PERTINENT INFORMATION (I.E. - GAS CALCS, INLET PRESSURE, ETC.) YOU HAVE REQUESTED. SINCE THIS IS A NEW SHEET, ONLY THE PAGE NUMBER HAS BEEN CLOUDED & A REVISION #2 TAG HAS BEEN INCLUDED WITH THE CLOUD. FMCEM GwoFTUXWLA Sheet Number(s): "Cloud" or highlight all areas of revision including date o revisio Received at the City of Tukwila Permit Center by: P�--Entered in Permits Plus on 3—� U — I s H: ApplicationsTouns-Applications On Line\2010 Applications\?-2010 - Revision Submittal.doc Revised: May 2011 UNIVERSAL REFRIGERATION T-kIC Page I of 2 Home Inicio en Espanol Contact Safety Washington State Departrnent of Labor & Industries UNIVERSAL REFRIGERATION INC Search L&I A-% Index Help &ty Secure I: `i<I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO BOX 614 GATES, CHRISTOPHER A AUBURN, WA98071-0614 253-939-6501 Principals KING County GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT VERNON, GUY E (End: 01 /01 /1980) JACKSON, SHELDON G (End: 01 /0111980) OSENBAUGH, CHARLES R (End:01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. Business type 600 699 723 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties COMMERCIAUINDUSTRIAUREFRIG License no. UNIVER1159RF Effective — expiration 12/06/1985— 04/01/2016 Bond ................. AMERICAN STATES INS CO $6,000.00 Bond account no. EX903622 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance ............................. American Economy Insurance Co $1,000,000.00 Policy no. 01 C179965210 Received by L&I Effective date 03/12/2015 04/0112015 Expiration date https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 4/14/2015 SEISMIC ROOF CURB ATTACHMENT DETAIL 211 Is IN.r I 4" I l4 4" \ ` 0 o 1-1/2" 3" o i � o 0 4" 3" RTU NEOPRENE GASKET WOOD NAILER X SECURE BRACKET TO CURB WITH (4) #10 SCREWS (I I ( 18 GA. RESTRAINT BRACKET FACTORY CURB NOTES: 1. ATTACH BRACKET TO INSIDE TOP OF CURB USING TEK SCREWS SUPPLIED AS SHOWN, ATTACH MOUNTING BRACKET TO CURB BEFORE MOUNTING BEFORE MOUNTING UNIT ON CURB. 2. AFTER SETTING UNIT ON CURB, ATTACH BOTTOM OF BRACKET TO BASE RAIL ON UNIT WITH TEK SCREWS SUPPLIED AS SHOWN. 3. A QUANTITY OF FOUR (4) SEISMIC BRACKETS PER ROOFTOP PACKAGE UNIT. 4. ONE SEISMIC BRACKET IS TO BE INSTALLED ON EACH CORNER OF THE ROOFTOP PACKAGE UNIT. NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. 11 GAS PIPING REGULATOR DETAIL ii Q 409.4 MP REGULATOR VALVES A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR 02 409.5 APPLIANCE SHUTOFF VALVE EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1, 409.5.0, OR 409.5.3 03 VENT LIMITERS ARE DESIGNED FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUE TO DIAPHRAGM FAILURE IS CRITICAL. VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13A15 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN VENT PROTECTION IS REQUIRED. ® 411.1.6 UNIONS A UNION FITTING SHALL BE PROVIDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN 6 FEET (1829 MM) OF THE APPLIANCE. Q 410.1 PRESSURE REGULATORS A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER PRESSURE THAN THE SUPPLY PRESSURE. LINE PRESSURE GAS REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSIZ21.80. ACCESS SHALL BE PROVIDED TO PRESSURE REGULATORS. PRESSURE REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUDOOR INSTALLATION. © A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE -MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. Q7 A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE -MEASURING INSTRUMENT. II HVAC ABBREVIATIONS II AFF ABOVE FINISHED FLOOR BDD BACKDRAFT DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CU CONDENSING UNIT DB DECIBEL DH DUCT HEATER DN DOWN EC EVAPORATOR COIL EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EG EXHAUST GRILLE ESP EXTERNAL STATIC PRESSURE EXH EXHAUST FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FPM FEET PER MINUTE FSD FIRE AND SMOKE DAMPER GA GAUGE GF GAS FURNACE GRD GRILLE, REGISTER, DIFFUSER HP HORSEPOWER, HEAT PUMP ID INSIDE DIMENSION IHP INDOOR (SECTION) HEAT PUMP IRH INFRARED HEATER KW KILOWATT MBH THOUSAND BTU PER HOUR MCD MOTORIZED CONTROL DAMPER NC NOISE CRITERIA NIC NOT IN CONTRACT NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIMENSION OR DIAMETER OHP OUTDOOR HEAT PUMP OSA OUTSIDE AIR OSCI OWNER SUPPLIED CONTRACTOR INSTALLED POC POINT OF CONNECTION RPM REVOLUTIONS PER MINUTE RA RETURN AIR RAG RETURN AIR GRILLE RTU ROOFTOP UNIT SA SUPPLY AIR SG SUPPLY GRILLE SP STATIC PRESSURE SSG SIDEWALL SUPPLY GRILLE TBD TO BE DETERMINED TG TRANSFER GRILLE TYP TYPICAL UH UNIT HEATER VFD VARIABLE FREQUENCY DRIVE VTR VENT TO ROOF VVT VARIABLE VOLUME AND TEMPERATURE HVAC LEGEND (D 0 INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN SIDEWALL EXHAUST FAN VAV FAN BOX CEILING EXHAUST FAN OM GAS METER ZD12 LJ VVT DAMPER THERMOSTAT T-BAR SUPPLY DIFFUSER T-BAR RETURN GRILLE z HARDLID SUPPLY DIFFUSER 11 HARDLID RETURN GRILLE FD FIRE DAMPER FSD FIRE SMOKE DAMPER VOLUME DAMPER SD SMOKE DETECTOR FLEXIBLE DUCT SA/RA ROUND DUCT UP l 1 ROUND DUCT DOWN 10x10 CD 300 CFM•10"0 DIFFUSER TAG NO changes ,hall be m� cf^aorl< �n�i p nclr' to the scope fihol.ra tier approval of Tulsa"ails Building Division Revisions will require a n^iv ,r an and may include additional plan re jq ,f f bmitfal � 11. '� Femnm Plan rQvilrvv approval is subject to errors and omisciori:,. Approval of construction documents does not authorize `Illy violation of any adopted code or ordinance. Ric ,ij0t Of apProvad Field Copy and conditions is acknowtodged: By: Date:.._.._YI�Y���s CRY of Tulvilla BUILDING DIVISION t.�IF := MIT PJI�u;��tn!Cal 1�(i'lurnbing 0 Gas Piping G`y of Tukwila D';1/ISION II HVAC NOTES II 1. DUCT INSULATION TO MEET THE REQUIREMENTS OF SECT- ION c403.2.7.2/3 OF THE 2012 WSEC AND SECTION 604 OF THE IECC (INTERNATIONAL ENERGY CONSERVATION CODE). 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2012 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3. DUCTWORK-MAINTRUNK IS R-4.2 IN CONDITIONED SPACES AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2012, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2012, SECTION C403.3.1. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON -SITE FOR INSPECTIONS. 6. ALL HVAC EQMT. TO BE LABELED TO THE SPACE SERVED. 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12 4' MAX., HORIZONTAL AT 10'4" MAX. WITH STRAP, OR 8'-0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF C403.2.9 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0&M MANUALS, SYSTEM BALANCE REPORT, AND A COMMIS- SIONING REPORT. - 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC C403.2.7. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER SEAMS SHALL BE SEALED. 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS. 11. WSEC FORMS, DUCTING PLANS, BALANCING FEATURES, AS WELL AS VENTILATION REQUIREMENTS (AS PER TABLE 403.3, 2012 IMC MINIMUM VENTILATION RATES) AND OCCUPANCY, ALONG WITH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. SCOPE OF WORK JOB#15046 1. INSTALL NATURAL GAS PIPING FOR NEW OWNER SUPPLIED EQUIPMENT NOTE: REFER TO TABLE 402.4(7) OF THE 2012 INTERNATIONAL FUEL GAS CODE FOR SCHEDULE 40 METALLIC PIPE @ 5 PSI CORRECTION LTR# ra a ICvoi=VVED FOR CODE COMPLIANCE APPROVED APR 0 2 201 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 3 0 2015 PERMIT CENTER CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 z O f_Z cr U) Q z O U) r 1t LO i PRINT/PLOT DATE: k 3/27/15 PROJECT START DATE: 3/24/15 DRAFTER: BSJ DESIGNER: HH PROJECT MANAGER: HH JOB NUMBER: 15046 SHEET NUMBER: A_ REV tWED FOR CODE COMPLIANCE APPROVED t APR 0 2 2015 RECEIVED CITY OF TUKWILA MAR 3 0 2015 PERMIT CENTER CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING-2001 z O I— CL U w 0 z O W �.i J U' w 0 cc IL R u0 T N 0-EC. 0.12Mr., 3/27/15 PROJECT START DATE: �VAC FLOOR PLAN H LNOTE: These plans are diagrammatical only. SCALE: 3/32" Please verify all dimensions at job site. PENDING CITY APPR SHEET NUMBER: 1 2 3 4 5 6 7 8 9 10 11 12 A - 1, 23 CFH SECTION (1) 1-1/2" g 1 1�2° SECTI ) S.E0OQLL(i6 SECTION (8) �� 1„_ SECTION (21) 800 CFH EXISTING 5 PSI M 1 �� SECTION(17) 3/4�� 3/4�� SECTION (7) @ 700' @ 5 PSI SECTION (6) AS METER SECTION (20) �NA1-IEN WATE-HE 114 CFH 114 CFH @ 758 CFH 11' SECTION (15) 200 FH 3/4" SE TION (4) 3/4" 200 CFH D 1-1/4" OON-(5) 2" EXISTING SECTION (12) EXISTING EXISTING EXISTING 3/4" E SECTION-(1-4) EX1S-TONG- STI 2 CFH EXIS ING SECTION 10 U D AS30 1-1/4" DN TO OVENS 3/4 �� 3/4" 1,740 CFH TOTAL 3/4" 172 CFH 3/4" F fi SECTION (13) ECTION (9) SECTION (3) 3/4" � �am. �. __ w u .� . �. _ .... .� _ .. _ EXI T NG TUBE HEATER � 3/ �� 200 FH- _ � SECTION (2) SECTION (1 9 S T (4) EX - -- - IG-TIN TIM H - OF - - _ UP r __ MTMTUM_ _.__ -. - 1 G 3) EXISTING 'S 236 CFH EXISTING EXISTI G 0 0 0 ® - 200 CFH MA—.-g 7MIELV�- 0 11 n K)- a, sr f i M GAS METER L ®FOIE c - CO PLIANCE APPROVED APR 0 2 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL MAR 3 0 2015 RM.LT_(-F_m-Ti: N NOTE: These plans are diagrammatical only. FULL BUI11- LDING PLAN SCALE.1 - 20-0 Please verify all dimensions at job site. GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 MEDIUM PRESSURE GAS PIPING Section 1 INLET PRESSURE I 6 PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 210.000 BTU CALCULATE CFH BASED ON INPUT 200 CFH PIPE ID REQUIRED= 0.511642 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedt MEDIUM PRESSURE GAS PIPING Section 2 INLET PRESSURE J57PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 210,000 BTU CALCULATE CFH BASED ON INPUT 200 CFH 1D REQUIRED= 0.511642 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 i PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 meta AUM PRESSURE GAS PIPING Section 3 ?T PRESSURE PSI =T TOTAL PRESSURE 19.7 3.5 PSI PRESSURE DROP 16.2 JT APPROXIMATE LINEAR LENGTH P400 FT JT BTUH INPUT OF EQUIPMENT BTU CULATE CFH BASED ON INPUTCFH PIPE ID REQUIRED= 0.666283 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table MEDIUM PRESSURE GAS PIPING INLET PRESSURE L.5 PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 210,000 BTU CALCULATE CFH BASED ON INPUT 200 CFH is pipe p 7) schedule 40 metallic pipe Section 4 PIPE ID REQUIRED= 0.511642 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedt MEDIUM PRESSURE GAS PIPING Section 5 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 210,000 BTU CALCULATE CFH BASED ON INPUT 200 CFH PIPE ID REQUIRED= 0.511642 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402,4(7) schedt MEDIUM PRESSURE GAS PIPING Section 6 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 840,000 BTU CALCULATE CFH BASED ON INPUT 800 CFH PIPE ID REQUIRED= 0.867663 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1" = 1.049 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.411 schedule MEDIUM PRESSURE GAS PIPING Section 7 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 120,000 BTU CALCULATE CFH BASED ON INPUT 114.2857 CFH PIPE ID REQUIRED= 0.413398 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedt MEDIUM PRESSURE GAS PIPING Section 8 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 960,000 BTU CALCULATE CFH BASED ON INPUT 914.2857 CFH PIPE ID REQUIRED= 0.912948 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1" =1.049 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedt MEDIUM PRESSURE GAS PIPING Section 9 INLET PRESSURE 5 PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 135,000 BTU CALCULATE CFH BASED ON INPUT 128.5714 CFH ID REQUIRED= 0.432372 INCHES ROUND UP TO NEAREST ID PIPE SIZE Wit" = .824 meta P pe pe GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 m MEDIUM PRESSURE GAS PIPING Section 10 INLET PRESSURE __JPSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 180,000 BTU CALCULATE CFH BASED ON INPUT 171 A286 CFH PIPE ID REQUIRED= 0.482458 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 11 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 315,M0 BTU CALCULATE CFH BASED ON INPUT 300 CFH PIPE ID REQUIRED= 0.597113 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 MEDIUM PRESSURE GAS PIPING Section 12 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 30.000 BTU CALCULATE CFH BASED ON INPUT 28.57143 CFH PIPE ID REQUIRED= 0.243772 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedul MEDIUM PRESSURE GAS PIPING Section 13 INLET PRESSURE l..�.�IPSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 345,000 BTU CALCULATE CFH BASED ON INPUT 328.5714 CFH metallic pipe PIPE ID REQUIRED= 0.618172 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 14 INLET PRESSURE ®PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 1,827,000 BTU CALCULATE CFH BASED ON INPUT 1740 CFH PIPE ID REQUIRED= 1.166602 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1 1/4" = 1.380 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 15 INLET PRESSURE 5 PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH QFT INPUT BTUH INPUT OF EQUIPMENT BTU CALCULATE CFH BASED ON INPUT CFH ID REQUIRED= 1.246075 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1 114" = 1.380 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table MEDIUM PRESSURE GAS PIPING INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 3,132,000 BTU CALCULATE CFH BASED ON INPUT 2982.857 CFH i) schedule 40 metallic pipe Section 16 PIPE ID REQUIRED= 1.432546 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1 1/2" = 1.610 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 17 INLET PRESSURE L�PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 120,000 BTU CALCULATE CFH BASED ON INPUT 114.2857 CFH PIPE ID REQUIRED= 0.413398 INCHES ROUND UP TO NEAREST ID PIPE SIZE 3/4" = .824 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 18 INLET PRESSURE PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 3,252,000 BTU CALCULATE CFH BASED ON INPUT 3097.143 CFH PIPE ID REQUIRED= 1.453215 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1 1/2" =1 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 19 INLET PRESSURE C 5 PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 1,075,000 BTU CALCULATE CFH BASED ON INPUT 1023.81 CFH PIPE ID REQUIRED= 0.953163 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1 112" =1.610 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 20 INLET PRESSURE C�PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 796,000 BTU CALCULATE CFH BASED ON INPUT 758.0952 CFH PIPE ID REQUIRED= 0.850058 INCHES ROUND UP TO NEAREST ID PIPE SIZE 1"= 1.049 GAS PIPING SPREADSHEET BASED ON 2012 IFGC Table 402.4(7) schedule 40 metallic pipe MEDIUM PRESSURE GAS PIPING Section 21 INLET PRESSURE �PSI INLET TOTAL PRESSURE 19.7 USE 3.5 PSI PRESSURE DROP 16.2 INPUT APPROXIMATE LINEAR LENGTH 700 FT INPUT BTUH INPUT OF EQUIPMENT 5,123,000 BTU CALCULATE CFH BASED ON INPUT 4879.048 CFH PIPE ID REQUIRED= 1.727942 INCHES ROUND UP TO NEAREST ID PIPE SIZE 2" = 2.067 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE GAS PIPING INSTALLATIONS Gas Natural Inlet Pressure 5.0 psi Pressure Drop 3.5 psi Specific Gravity 0.60 PIPE SIZE (inch) Nominal 1/2 3/. 1 1'/. 1 1'/2 2 2% 3 4 Actual 10 0.622 0,824 1 1.049 1 1.380 1 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Cubic Feet of Gas Per Hour 10 3,190 6,430 11,800 24,200 36,200 69,700 111,000 196,000 401,000 20 2,250 4,550 8,320 17,100 25,000 49.300 78,600 139,000 283.000 30 1.840 3,720 6,790 14,000 20.900 40.300 04.200 113,000 231,000 40 1,590 3,220 5,880 12,100 18,100 34,900 55,600 98,200 200,000 50 1,430 2,880 5.260 10,800 16,200 31,200 49.700 87,900 179,000 60 1,300 2,630 4,800 9,860 14.800 28,500 45,400 80,200 164,000 70 1,200 2,430 4,450 9,130 13,700 26,400 42,000 74,300 151.000 80 1,150 2,330 4.260 8,540 12,800 24,700 39,300 69,500 142.000 90 1.060 2,150 3,920 8,050 12,100 23,200 37,000 65,500 134.000 100 979 1.980 3.620 7,430 11,100 21,400 34,200 60,400 123.000 125 876 1,770 3.240 6,640 9,950 19,200 30,600 54,000 110.000 150 786 1,590 2,910 5,960 8,940 17,200 27,400 48.500 98.900 175 728 1,470 2,690 5,520 8,270 15,900 25.400 44.900 91.600 200 673 1,360 2,490 5.100 7.650 14,700 23,5W 41,500 84,700 250 558 1,170 2,200 4.510 6,760 13,000 20,800 36.700 74,900 300 506 1,060 1.990 4,090 6,130 11,800 18.800 33.300 67.800 350 465 973 1,830 3.760 5,640 10,900 17,300 30,600 62,400 400 433 905 1,710 3,500 5,250 10,100 16.100 28,500 58.100 450 406 849 1,600 3,290 4,920 9,480 15,1(H) 26,700 54,500 500 384 802 1,510 3,100 4,650 8,950 14,300 25,200 51,500 550 364 762 1,440 2,950 4,420 8,500 13,600 24,000 48,900 600' 348 727 1,370 2,810 4,210 8.110 12,900 22,900 46,600 650 333 696 1,310 2,690 4.030 7,770 12,400 21,900 44,600 700 320 669 11 2,590 3.880 7,460 11,900 21,000 42.900 750 308 644 1,210 2,490 3,730 7.190 11,500 20,300 41.300 800 298 622 1,170 2,410 3,610 6,940 11,100 19,600 39,900 850 298 602 1,130 2,330 3,490 6,720 10,700 18.900 38,600 900 279 584 1,100 2,260 3,380 6,520 10,400 18,400 37,400 950 271 567 1,070 2.190 3,290 6,330 10.100 17,800 36,400 1,000 264 551 1,040 2,130 3,200 6,150 9,810 17,300 35,400 1,100 250 524 987 2,030 3,030 5,840 9,320 16,500 33,600 1,200 239 500 941 1,930 2,900 5.580 8,890 15,700 32,000 1,300 229 478 901 1,850 2,770 5,340 8,510 15,000 30,700 1,400 220 460 866 1,780 2,660 5,130 8,180 14,500 29.500 1.500 212 443 834 1.710 2,570 4,940 7,880 13,900 28,400 1,600 205 428 806 1,650 2,480 4,770 7,610 13,400 27,400 1,700 198 414 780 1,600 2,400 4,620 7.360 13,000 26,500 1.800 192 401 756 1.550 2,330 4,480 7,140 12,600 25,700 1 186 390 734 1.510 2.260 4,350 6,930 12,300 25,000 2,000 181 379 714 1,470 2.200 4,230 6.740 11.900 24,300 For S1: ) inch = 25.4 mm, 1 foot = 304.8 min. 1 pound per square inch = 6.895 1 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.2931 W. 1 cubic foot per hour = 0.0283 m'/h, 1 degree = 0.01745 rad. Note: All table entries have been rounded to three significant digits. See the commentaryfor Section 402.4. r � REVIEVifED " OR BODE COMPLIANCE 2012 INTERNATIONAL FUEL GAS CODE`COMMENTARY APppOVED APR 0 2 2015 City of Tukwila BUILDING DIVISION 4-21 RECEIVED CITY OF TUKWILA MAR 3 0 2015 PERMIT CENTER z O CL rr U U) W n z O U) W cc W n WU) U7 �= O �U) rr W W 13-Id � Ln CV 00 00 U 0-) � Q J W U W O � O LIL C/) Elf C 73 Q LIJ � O N NR� CID � PRINT/PLOT DATE,,:-, 3/27/15 PROD _ 3/24/15 ' A E d • BSJ DESIG R: HH PROJECT MANAO�ffR. HH JOB NUMBER: 15046' SHEET NUMBS ii l NOTE: These plans are diagrammatical only. Please verify all dimensions at job site.