City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone:206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 0003400018 Permit Number: PG15-0032
Address: 9725 E MARGINAL WAY S BLDG 9-101 Issue Date: 4/10/2015
Permit Expires On: 10/7/2015
Project Name: BOEING #9-101- DE BULK OVEN
Owner:
Name:
BOEING COMPANY THE
Address:
PO BOX 3707 M/C 20-00 PROPERTY
TAX DEPT, SEATTLE, WA, 98124
Contact Person:
Name:
CONNIE HARDIN
Phone: (206) 250-4530
Address:
4600 S 134 PL , SEATTLE, WA, 98168
Contractor:
Name:
HOLADAY PARKS, INC.
Phone: (206) 248-9700
Address:
PO BOX 69208, SEATTLE, WA, 98188
License No:
HOLADPI379NO
Expiration Date: 9/3/2015
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALL GAS PIPING TO EXISTING OVEN
Valuation of Work: $7,000.00 Fees Collected: $126.76
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW
SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature: Date: O /0 lS
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating constru tion or the performance of work. I am authorized to sign and obtain this
development ermit and a ree o conditions attached to this permit.
Signatur Date: l�
Print Na JC_t I/aW-
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
9: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
10: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
12: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
9002 ROUGH -IN GAS PIPING
9001 UNDERGROUND
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.aov
Plumbing/Gas Permit No. t5 .• Y�
Project No.
Date Application Accepted:
Date Application Expires:q—_1 5
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
:CONTACT PERSON -person receiving all project
communication
Name:
n
Address:
12001- PJ
City: StateU IL • Zip•
Phon Fax:7.6
Emai
• .
:►
Valuation of Project (contractor's bid price): $_ Dom/
Scope of Work (please proy4e detailed information):
"N
vk�" i " p y-d�
Building Use (per Int'l Buildin Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Co Assessor's Tax No.
Suite Number: Floor:
New Tenant: ❑ .....Yes .. to
PLUMBING CONTRACTOR INFORMATION
Company Name:
tno
Address:L4
Lot!) sALr
City: State: Q Zilrt
Phone: Fax:
Contr Reg No. p Date:
Tukwila Business License No.:
Sewer:
011
H:WpplicationsTo-ts-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-1 Ldo"
Revised: August 2011'.
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
ease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
I
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Print Name:
Mailing
Date: 7� 1 z— I
Day Telephone
City State — —Zip
H:\Apphmtions\Fornns-App1ications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-1 Ldocx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
ACCOUNTQUANTITY
PAID
$882.20
M15-0028 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018
$755.44
MECHANICAL
$726.38
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$548.60
PLAN CHECK FEE
R000.322.102.00.00
0.00
$145.28
TECHNOLOGY FEE
$29.06
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$29.06
PG15-0032 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018
$126.76
GAS
$121.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.38
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
• .FEES PAIDRECEIPT:1
R000.322.900.04.00
0.00
$4.88
Date Paid: Friday, March 13, 2015
Paid By: CONNIE HARDIN
Pay Method: CREDIT CARD 03098G
Printed: Friday, March 13, 2015 10:24 AM 1 of 1
SYSTEMS
- N INSPECTION RECORD
Retain cowith ermi
2- � Ep�
1
E----------- I a pt
py
INSPECION NO. PERMIT NO,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 438-9350
I J, ct- --
Type at Inspectiop:'
Address:
q 7 -2-3 �,q ( Wvol
Date Called.
ff',d -
Special Instructions: V
4M
9,o®v . . ....
Date Wanted, a.m.
f - rc p.m.
RequesVer:
r q f5 1740
Phone No:
2a6 - 7-0 -7-
Inspector: Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter 8tvd.. Suite 100. Catt to schedule reinspection.
1ff
INSPECTION RECORD 00 3
Retain a copy with permit K7 /I
PECTIQN NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Sotithcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
P 't -
ec
Type of lns5ict
X
5�j""
- R
Address. V
D te Called:
Special instructions, v
Date W f d. am.
17 - j--
aid 11-to
r rj"- p.m.
I
Cq(( 15- W r' AJA f-jj�j
eq Ruest r.
Pq � P t-b ((*d-Q 1dT114g
113hone
No:
)-G — 7 -T,
Vow I
REINSPECTION FEE REQUIRED, Prior to next inspection. fee must be
paid at 6300 Southcenter Btvd.. Suite 100, Call to schedule reinspection.
Job# Boeing # (W1943174) Job Name 9-101 Debulk Oven Gas Sizin
FSi consulting engineers
Subject Gas Burner Line Sizing for DEBULK Oven (W1943174) Date 9/29/2014
By KRL �r *k* v Sheet 1 of 1
oft - ---- WL 1►■
Capacity per Burner:
4.0 MM BTU/HR
=
4000 MBTU/HR
(2) Burner Capacity Need = 8000 MBTU/HR = 8000 Cubic Feet of Gas/HR
Pressure need at equipment
=
12 psi
Plant Gas Supply Pressure:
=
29-30 psi
Pipe Type:
Schedule
40 Metallic
Length of piping run:
200 ft
Pressure drop from supply to point of use (found from Table 402.4(7) reference below):
=
3.5 psi
Pressure Available at Equipment
=
25.5-26.5 psi
Per 20121FGC, Table 402.4(7)
E
MFOLU
N
E
Maximum Supply Capacity Available with Following Assumptions
APO
E
-
200 ft of pipe length
-
2" Pipe
-
Natural Gas-BuUm
N
=
14,700 Cubic Feet of Gas Per Hour
tj
Capacity Needed
=
8000 Cubic Feet of Gas Per hour
I-T
R
Since the needed capacity (8000) is less than the capacity available (14,700) the pressure
supplied at the equipment (25.5-26.5 psi) is larger than the pressure needed at the equipment
(12 psi) a 2" Schedule 40 Metallic Pipe is an adequate sizing.
pECE1Vl�C3
t
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
March 20, 2015
CONNIE HARDIN
4600 S 134 PL
SEATTLE, WA 98168
RE: Correction Letter # 1
PLUMBING/GAS PIPING Permit Application Number PG15-0032
BOEING #9-101 - DE BULK OVEN - 9725 EAST MARGINAL WAY S
Dear CONNIE HARDIN,
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these
comments.
• (GENERAL NOTE)
PLAN SUBMITTALS: (Min. size l 1x17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same. size sheets as those previously submitted.)
(If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp,
not copied) by Washington State licensed architect, structural engineer or civil engineer.
(BUILDING REVIEW NOTES)
1. The cover sheet has a lot of unrelated information for this permit to include outdated code notes and special
inspections. Provide a cover sheet indicating current code compliance and clearly indicating the scope of work for
this permit only and if applicable any special inspections required. Please only provide sheets related to the gas
piping.
2. Provide gas pipe sizing calculations.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-431-3655.
Sincerely,
c
Bill Rambo
Permit Technician
File No. PG15-0032
OPY
PLANEREVIE4W/ROUTING SLIP
PERMIT NUMBER: PG15-0032 DATE: 4-1-15
PROJECT NAME: BOEING #9-101-DE BULK OVEN
SITE ADDRESS: 9725 E MARGINAL WAY S
Original Plan Submittal
X Response to Correction Letter # I
Revision #
Revision #
DEPARTMENTS:
4
Building Division Fire Prevention ❑
Public Works ❑ Structural ❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
before Permit Issued
after Permit Issued
Planning Division ❑
Permit Coordinator IN
DATE: 4-2-2015
Structural Review Required ❑
DATE:
DUE DATE: 4-30-15
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG15-0032 DATE: 03/13/15
PROJECT NAME: BOEING #9-101- DE BULK OVEN
SITE ADDRESS: 9725 E MARGINAL WAY S
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
t� 3-15-K
Building Division IN Fire Prevention ❑ Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 03/17/15
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
DUE DATE:
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only Z Qj
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg j4'S-- Fire ❑ Ping ❑ PW ❑ Staff Initials:
04/14/15
12/18/2013
r-
�J,�,�, wqs City of Tukwila
Department of Community Development
` 6300 South Boulevard, Suite # 100 �it+lii
%i? Tukwila, Washington 98188 6F T1J
XWU
�' •......_....... Phone: 206-431-3670'APR'O 12015
7908 Fax: 206-431-3665
Web site: http:•//www.ci.tukwila.wa.us
Iaa4T ��t�
Revision submittals must he submitted in person at the Permit Center. Revisions will not he accepted through
the mail, fax, etc.
Date: /w/ � Plan ChecWPermit Number:
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
. PG15-0032
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Boeing #9-101 — De Bulk Oven
Project Address: 9725 E Marginal Way S
Contact Person: Gos1nZ gC!/'i/i�1 Phone Number: 264v 'Z�-O• y93�
Summary of Revision:
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
[ Entered in TRAKiT on
\applications\fomis-applications on line\revision submittal
Created: 8-13-2004
Revised:
HOLADAY PARKS INC
Page 1 of 3
Home inicio en Iispaflol Contact
Safety
CAm Washington State Department of
j Labor & Industries
HOLADAY PARKS INC
Search L&I I "
A -'!.Index Help My Secure L,&I
Claims & Insurance Workplace Rights Trades & Licensing
Owner or tradesperson 4600 S 134TH PL
PARKS, GERALD T JR SEATTLE, WA98168
206-248-9700
Principals KING County
PARKS, GERALD T JR, PRESIDENT
NAILON, JUNE ANNETTE, VICE PRESIDENT
O'CONNOR, BONNY K, SECRETARY
BECK, DAVID CLARENCE, TREASURER
VAN DER VEEN, ERIC M, VICE PRESIDENT
(End: 08/14/2013)
PIZZEY, GRACE KATHERINE, VICE
PRESIDENT
(End: 08/14/2013)
VAN DER VEEN, JULIE
ELIZABETH, MEMBER
(End: 08/14/2013)
CONNELL, DANIEL AARON, MEMBER
(End: 08/14/2013)
GIRI, BUTT, MEMBER
(End: 08/14/2013)
KIEL, RINALD HOWARD, MEMBER
(End: 08/14/2013)
WHITMYRE, CHRISTIAN, MEMBER
(End: 08/14/2013)
NELSON, MICHAEL, SECRETARY
(End: 11 /04/2010)
PARKS, DAVID L, TREASURER
(End: 11/04/2010)
TALBOT, PAUL, TREASURER
(End: 11 /04/2010)
Doing business as
HOLADAY PARKS INC
WA UBI No. Business type
578 004 089 Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
......._....................... .--.................................
Meets current requirements.
License specialties
GENERAL
License no.
HOLADPI379NO
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 04/10/2015