HomeMy WebLinkAboutPermit PG15-0032 - BOEING #9-101 - OVEN GAS PIPINGBOEING #9-101 - DE BULK OVEN 9725 E MARGINAL WAY S BLDG 9-101 PG15-0032 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 0003400018 Permit Number: PG15-0032 Address: 9725 E MARGINAL WAY S BLDG 9-101 Issue Date: 4/10/2015 Permit Expires On: 10/7/2015 Project Name: BOEING #9-101- DE BULK OVEN Owner: Name: BOEING COMPANY THE Address: PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Contact Person: Name: CONNIE HARDIN Phone: (206) 250-4530 Address: 4600 S 134 PL , SEATTLE, WA, 98168 Contractor: Name: HOLADAY PARKS, INC. Phone: (206) 248-9700 Address: PO BOX 69208, SEATTLE, WA, 98188 License No: HOLADPI379NO Expiration Date: 9/3/2015 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL GAS PIPING TO EXISTING OVEN Valuation of Work: $7,000.00 Fees Collected: $126.76 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: O /0 lS I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru tion or the performance of work. I am authorized to sign and obtain this development ermit and a ree o conditions attached to this permit. Signatur Date: l� Print Na JC_t I/aW- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 9: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 10: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 12: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.aov Plumbing/Gas Permit No. t5 .• Y� Project No. Date Application Accepted: Date Application Expires:q—_1 5 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" :CONTACT PERSON -person receiving all project communication Name: n Address: 12001- PJ City: StateU IL • Zip• Phon Fax:7.6 Emai • . :► Valuation of Project (contractor's bid price): $_ Dom/ Scope of Work (please proy4e detailed information): "N vk�" i " p y-d� Building Use (per Int'l Buildin Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Co Assessor's Tax No. Suite Number: Floor: New Tenant: ❑ .....Yes .. to PLUMBING CONTRACTOR INFORMATION Company Name: tno Address:L4 Lot!) sALr City: State: Q Zilrt Phone: Fax: Contr Reg No. p Date: Tukwila Business License No.: Sewer: 011 H:WpplicationsTo-ts-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-1 Ldo" Revised: August 2011'. bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets I Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Mailing Date: 7� 1 z— I Day Telephone City State — —Zip H:\Apphmtions\Fornns-App1ications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $882.20 M15-0028 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $755.44 MECHANICAL $726.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $548.60 PLAN CHECK FEE R000.322.102.00.00 0.00 $145.28 TECHNOLOGY FEE $29.06 TECHNOLOGY FEE R000.322.900.04.00 0.00 $29.06 PG15-0032 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE • .FEES PAIDRECEIPT:1 R000.322.900.04.00 0.00 $4.88 Date Paid: Friday, March 13, 2015 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 03098G Printed: Friday, March 13, 2015 10:24 AM 1 of 1 SYSTEMS - N INSPECTION RECORD Retain cowith ermi 2- � Ep� 1 E----------- I a pt py INSPECION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 I J, ct- -- Type at Inspectiop:' Address: q 7 -2-3 �,q ( Wvol Date Called. ff',d - Special Instructions: V 4M 9,o®v . . .... Date Wanted, a.m. f - rc p.m. RequesVer: r q f5 1740 Phone No: 2a6 - 7-0 -7- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter 8tvd.. Suite 100. Catt to schedule reinspection. 1ff INSPECTION RECORD 00 3 Retain a copy with permit K7 /I PECTIQN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Sotithcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P 't - ec Type of lns5ict X 5�j"" - R Address. V D te Called: Special instructions, v Date W f d. am. 17 - j-- aid 11-to r rj"- p.m. I Cq(( 15- W r' AJA f-jj�j eq Ruest r. Pq � P t-b ((*d-Q 1dT114g 113hone No: )-G — 7 -T, Vow I REINSPECTION FEE REQUIRED, Prior to next inspection. fee must be paid at 6300 Southcenter Btvd.. Suite 100, Call to schedule reinspection. Job# Boeing # (W1943174) Job Name 9-101 Debulk Oven Gas Sizin FSi consulting engineers Subject Gas Burner Line Sizing for DEBULK Oven (W1943174) Date 9/29/2014 By KRL �r *k* v Sheet 1 of 1 oft - ---- WL 1►■ Capacity per Burner: 4.0 MM BTU/HR = 4000 MBTU/HR (2) Burner Capacity Need = 8000 MBTU/HR = 8000 Cubic Feet of Gas/HR Pressure need at equipment = 12 psi Plant Gas Supply Pressure: = 29-30 psi Pipe Type: Schedule 40 Metallic Length of piping run: 200 ft Pressure drop from supply to point of use (found from Table 402.4(7) reference below): = 3.5 psi Pressure Available at Equipment = 25.5-26.5 psi Per 20121FGC, Table 402.4(7) E MFOLU N E Maximum Supply Capacity Available with Following Assumptions APO E - 200 ft of pipe length - 2" Pipe - Natural Gas-BuUm N = 14,700 Cubic Feet of Gas Per Hour tj Capacity Needed = 8000 Cubic Feet of Gas Per hour I-T R Since the needed capacity (8000) is less than the capacity available (14,700) the pressure supplied at the equipment (25.5-26.5 psi) is larger than the pressure needed at the equipment (12 psi) a 2" Schedule 40 Metallic Pipe is an adequate sizing. pECE1Vl�C3 t City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director March 20, 2015 CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG15-0032 BOEING #9-101 - DE BULK OVEN - 9725 EAST MARGINAL WAY S Dear CONNIE HARDIN, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size l 1x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same. size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. The cover sheet has a lot of unrelated information for this permit to include outdated code notes and special inspections. Provide a cover sheet indicating current code compliance and clearly indicating the scope of work for this permit only and if applicable any special inspections required. Please only provide sheets related to the gas piping. 2. Provide gas pipe sizing calculations. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, c Bill Rambo Permit Technician File No. PG15-0032 OPY PLANEREVIE4W/ROUTING SLIP PERMIT NUMBER: PG15-0032 DATE: 4-1-15 PROJECT NAME: BOEING #9-101-DE BULK OVEN SITE ADDRESS: 9725 E MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # I Revision # Revision # DEPARTMENTS: 4 Building Division Fire Prevention ❑ Public Works ❑ Structural ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: before Permit Issued after Permit Issued Planning Division ❑ Permit Coordinator IN DATE: 4-2-2015 Structural Review Required ❑ DATE: DUE DATE: 4-30-15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0032 DATE: 03/13/15 PROJECT NAME: BOEING #9-101- DE BULK OVEN SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: t� 3-15-K Building Division IN Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/17/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only Z Qj CORRECTION LETTER MAILED: Departments issued corrections: Bldg j4'S-- Fire ❑ Ping ❑ PW ❑ Staff Initials: 04/14/15 12/18/2013 r- �J,�,�, wqs City of Tukwila Department of Community Development ` 6300 South Boulevard, Suite # 100 �it+lii %i? Tukwila, Washington 98188 6F T1J XWU �' •......_....... Phone: 206-431-3670'APR'O 12015 7908 Fax: 206-431-3665 Web site: http:•//www.ci.tukwila.wa.us Iaa4T ��t� Revision submittals must he submitted in person at the Permit Center. Revisions will not he accepted through the mail, fax, etc. Date: /w/ � Plan ChecWPermit Number: ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued . PG15-0032 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9-101 — De Bulk Oven Project Address: 9725 E Marginal Way S Contact Person: Gos1nZ gC!/'i/i�1 Phone Number: 264v 'Z�-O• y93� Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: [ Entered in TRAKiT on \applications\fomis-applications on line\revision submittal Created: 8-13-2004 Revised: HOLADAY PARKS INC Page 1 of 3 Home inicio en Iispaflol Contact Safety CAm Washington State Department of j Labor & Industries HOLADAY PARKS INC Search L&I I " A -'!.Index Help My Secure L,&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 4600 S 134TH PL PARKS, GERALD T JR SEATTLE, WA98168 206-248-9700 Principals KING County PARKS, GERALD T JR, PRESIDENT NAILON, JUNE ANNETTE, VICE PRESIDENT O'CONNOR, BONNY K, SECRETARY BECK, DAVID CLARENCE, TREASURER VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUTT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11 /04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11 /04/2010) Doing business as HOLADAY PARKS INC WA UBI No. Business type 578 004 089 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ......._....................... .--................................. Meets current requirements. License specialties GENERAL License no. HOLADPI379NO https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 04/10/2015