Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG15-0040 - SKB MARKET READY - GAS PIPING
0 m 33 V41 a m w 0 a W41 606 INDUSTRY DR PG15-0040 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 0223400010 Permit Number: PG15-0040 Address: 606 INDUSTRY DR Issue Date: 4/3/2015 Permit Expires On: 9/30/2015 Project Name: SKB MARKET READY Owner: Name: BLUE DOG PROPERTIES TRUST Address: PO BOX 847 C/O THOMSON REUTERS PTS, CARLSBAD, WA, 92018 Contact Person: Name: INNA BUCKWALTER Address: 1916 220 ST SE STE M101, BOTHELL, WA, 98021 Contractor: Name: PACIFIC AIR CONTROL INC Address: 1916 220TH ST SE SUITE M101, BOTHELL, WA, 98021 License No: PACIFAC230P8 Lender: Name: Address: Phone: (206) 512-9647 Phone: Expiration Date: DESCRIPTION OF WORK: ROUTE NEW GAS PIPING FROM GAS UNIT HEATER TO NEW METER (INSTALLED/DESIGNED BY OTHERS) Valuation of Work: $200.00 Fees Collected: $84.50 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 A Permit Center Authorized Signature: �(�( �J C Date: Ps I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature Print Nat This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND CITY OF TUKWL.-_ _ Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. to 001to Project No. Date Application Accepted: Date Application Expires: or office use only PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION j l King Co Assessor's Tax No.: d 2-2 37600/00 Site Address: &ob n S .0 Ve 7u kwj Lq WA Suite Number: 6 f% A Floor: / S*� Tenant Name: %) -PQ New Tenant: ❑ .....Yes JO..No PROPERTY OWNER Name N-CkIDh-r6YOVQ( FK1-'CINiA2 AWL Address: UIO NW /j'�"5hqtPtt s�30 City: .�/cn j State: p Zip: 972D CONTACT PERSON - person receiving all project communication h p Name: //V70 Address: /Y/6 2207% S4 JE Jf.2 M )0/ City: e-LL State: WA Zip: q8D 1 Phone: _ _ 2'g 647 Fax: 2 D I - � ` Q-22-7 Email: I NNA 8 pACi pjCh_ll p Con-jp404 Valuation of Project (contractor's bid price): $ 2 X PLUMBING CONTRACTOR INFORMATION Company Name: 'PaCiFIC 47R C1011*02 14 Address: MIA 220-M Si SE 3-1-,e IW O City: ,[-(_ State: t y 4 Zip: 4��Q� Phone: 2—D6�i_''11 / 802_ / 39 ax: V2 Z _ 3 L `DJ 22 Contr Reg No.: 1t7n � 1PAc Z30PpExp Date: Tukwila Business License No.: 814S - 09 9 -�;D9 / Scope of Work (please provide detailed information): QS iz^,rl Aea-l� teu) fP Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code)): Utility Purveyor: Water: Wes/ R4- �7�� Sewer: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 l.docx Revised: August 2011 Page 1 of 2 bh Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity -elow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water cooler (per head Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow rotections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch 51 mm diameter Gas piping outlets / Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER -OR AUTHORIZED AGENT: Signature: _ Date: 3/ / 3//' .-. Print Name: %N NA jU,C��pL(iQ ej-21Q Day Telephone: Z D6 - �7 2- '- 91 Y7 Mailing Address: I N I L 22 �i S+ ,� E & _ M )n I Be+6,e LL IVA 9F02/ City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $332.13 EL15-0268 Address: 606 INDUSTRY DR Apn: 0223400010 $72.77 ELECTRICAL $69.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $69.30 TECHNOLOGY FEE $3.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.47 M15-0029 Address: 606 INDUSTRY DR Apn: 0223400010 $174.86 MECHANICAL $168.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $102.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $33.63 TECHNOLOGY FEE $6.73 TECHNOLOGY FEE R000.322.900.04.00 0.00 $6.73 PG15-0040 Address: 606 INDUSTRY DR Apn: 0223400010 $84.50 GAS $81.25 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $16.25 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.25 'TOTAL FEES PAID BY RECEIPT: . . . Date Paid: Tuesday, March 24, 2015 Paid By: INNA BUCKWALTER Pay Method: CREDIT CARD 085216 Printed: Tuesday, March 24, 2015 1:53 PM 1 of 1 C SYSTEMS � IS - C)OI-t O INSPECTION 6RECORD] W I Retain a copy with permit INSPECTION NO. PERM!T NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Prajec pe of in ection: Address: 1��t D ate Called: Special Instructions: /1 Date Wanted: p.m. Requester: Phone No: 11')�/� Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. I , LOW, '40 INSPECTION RECORD00yo ko I Retain a copy with permit I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 _4206) 4" 1 -. 3670 -(� Permit Inspection Request Line (206) 438-9350 (p4t_ T y IT Project: Type of Inspectipn: ess A&�6P-P- Date Called: I -- Special Instructions. Date WarvteU7- a.m. lRequester: i&c L'1- C ---- P on No: ty 2,3 CID v REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 1 /4/2016 INNA BUCKWALTER 1916 220 ST SE STE M 10 1 BOTHELL, WA 98021 RE: Permit No. PG 15-0040 SKB MARKET READY 606 INDUSTRY DR Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/23/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. OTC 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/23/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File No: PG15-0040 6300 Southcenter Boulevard Suite #100 e Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 8/6/2015 INNA BUCKWALTER 1916 220 ST SE STE M101 BOTHELL, WA 98021 RE: Permit No. PG15-0040 SKB MARKET READY 606 INDUSTRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/30/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/30/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, --1W Bill Rambo Permit Technician File No: PG15-0040 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0040 DATE: 03/24/15 PROJECT NAME: SKB MARKET READY SITE ADDRESS: 606 INDUSTRY DR X Original Plan Submittal Revision # Response to Correction Letter # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �3 -fwc., --ul l �1GJ Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/26/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/23/15 Approved 0 Corrections Required ❑ (corrections entered in Reviews) Notation: Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: L4 I (OA) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PACIFIC AIR CONTROL INC Page I of 2 inWashington State Department of Labor & Industries PACIFIC AIR CONTROL INC Owner or tradesperson RUTTAN, GARY JAMES Principals RUTTAN, GARY JAMES, PRESIDENT CRAWFORD, LARRY C, SECRETARY (End: 10/05/2011) Doing business as PACIFIC AIR CONTROL INC WA UBI No. 601 298 907 License Home Inicio en Espanol Contact Safety Claims & Insurance 1916 220TH ST SE STE 101 BOTHELL, WA 98021-8427 206-682-6393 SNOHOMISH County Business type Corporation Search L&I A-7, Index Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................................................................... Meets current requirements. License specialties Heating/VenVAir-Conditioning and Refrig (HVAC/R) License no. PACIFAC230P8 Effective — expiration 10/28/1977-10/01/2015 Bond ................. TRAVELERS CAS & SURETY $6,000.00 Bond account no. 104920215 Received by L&I Effective date 05/09/2007 05/26/2007 Expiration date Until Canceled https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601298907&LIC=PACIFAC23OP8&SAW= 04/03/2015 HVAC GENERAL NOTES 1. VERIFY SITE CONDITIONS. 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC. 3. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. 4. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. 5. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. 6. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT", 2012. 7. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED PER LOCAL CODE. 8. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN. 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS -BUILT DRAWING. 10. COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OF OCCUPANCY, PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCE WITH THE PROVISIONS OF SECTION C408 OF THE 2012 WSEC 11. WALK-THRU INSTRUCTION: PROVIDE ON SITE WALK-THRU FOR CUSTOMER TO DEMONSTRATE OPERATION OF SYSTEM AND ANSWER QUESTIONS. 12. ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE FACTORY ROOF CURB FOR NOISE CONTROL. 13. GAS PIPE: SCHEDULE 40, BLACK STEEL. PAINT PIPE EXPOSED TO WEATHER. 14. SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM. 15. PIPE HANGERS: SWIVEL LOOP STYLE, MICHIGAN NO.100 OR CLEVIS STYLE, NO.400 OR EQUAL BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS. 16. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES (2012 IMC SECTION 301.10). LINE VOLTAGE WORK BY OTHERS. DUCT NOTES 1. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE 2012 IMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS NOTED. 2. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF DIFFUSERS. 3. DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALL BE INSULATED TO MINIMUM OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.7 OF 2012 WSEC. 4. DUCT SEALING -GENERAL: 0 TO 2" STATIC PRESSURE - SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS. ABOVE 2"-SEAL SEAMS, JOINTS AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS-181" GRAY OR APPROVED EQUAL PER UL 181 A-M, 181 B-M LISTED. OUTSIDE: POLYURETHANE, MAMECO VULKEM 116. OR APPROVED EQUAL. 5. TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER SMACNA STANDARD. 6. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED. 7. SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA. 8. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK-UPS TO ISOLATE AIR HANDLING EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) 9. DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR RECTANGULAR DUCTS THAT ARE NOT LINED. PROVIDE CIRCULAR EQUIVALENT OF RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE SUBSTITUTED TO BETTER FIT SPACE. 10. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL OPENINGS. NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A UNIT HEATER SCHEDULE UNIT NO. SERVICE & LOCATION MANUFACTURER & MODEL NO. HEATING, MB AFUE BLOWER ELECTRICAL WT/ INPUT OUTPUT CFM RPM I HP VOLT/PH APM LBS UH-1 BLDG 4, STE 606A REZNOR V3 SERIES UDAP-30 1 30 24.6 82 456 1 1550 10.06 1 115V/1 1.9 54 NOTES: 1. EQUIPMENT SIZING PER WA ENERGY CODE 2012 C202 (SEMI -HEATED SPACE). 2. UNIT HEATER PROVIDED WITH INTERMITTENT IGNITION. 3. UNIT HEATER IS SERVED FOR FREEZE PROTECTION AND PROVIDED WITH LOCKABLE THERMOSTAT. LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARK #5 LESS UP RR OPER R/W TAX PARCEL NUMBER: 022340-0010 (I NCWP ANDOVER EXECUTIVE PARK BUILDING 4 SITE PLAN SCALE: 1 "=30'-0" - REVISIONS P"da ass .174-111 hr± made to the scope prior approval of ^` d� Bui± dir,,g Division. ;1�ls vAl require a now plan submittal 1 Unu ay in ;;ude additional plan roviovi fees. I R S17PA- ' M1 fir. ,T €� f r., �, SIT MULi�anical Clac.l iwul ta'riumaing Gas Piping of \/IrIKIITY WAIF PARCEL: 022340-001ONCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A t fan rcvioW aPpprcj%ird i,3 su?L�p < to cr ors cnd ©missiom. A n _,1 , ',,;c. -lnr r�, a. C, tr S 0s !-tr,3(3r0llt�tf 0 Cull fL:., ..:;1 w� u riu�+l.y C�,3i;x..� riW.1; autholIzo the Violation of any %is ,D for oirdinm 0. Roccipt of approved Fialcl Copy and 1 " ;ef`� is ac'�ilotiti�Iod ow: Datl�:/,1%s LEGEND & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION ® ® SUPPLY DUCT FIRE DAMPERED DUCT 00 RETURN/EXHAUST DUCT PENETRATION OF A HORIZONTAL SEPARATION SL SOUNDLINED DUCT ® FIRE DAMPERED DUCT VD MANUAL VOLUME DAMPER PENETRATION OF A FC FLEX CONNECTOR VERTICAL SEPARATION TV TURNING VANES m TIMER 0-4 HR ADJUSTABLE EC END CAP O THERMOSTAT/HVAC UNIT # ® SD SUPPLY DIFFUSER, CEILING ® SENSOR/HVAC UNIT # ® MG MAKEUP GRILLE Q SENSOR (CEILING MOUNT) 171 RG RETURN GRILLE, CEILING EXHAUST FAN 0 EG EXHAUST GRILLE, CEILING PIPE/DUCT UP 0 TG TRANSFER GRILLE, CEILING PIPE/DUCT DOWN �-- SIDEWALL SUPPLY/MAKEUP PIPE TEE DOWN -I -� SIDEWALL RETURN/EXHAUST PIPE TEE UP F1 _-_2_771 EQUIPMENT TAG EXIST DUCTWORK, EQUIP AFF ABOVE FINISHED FLOOR NEW DUCTWORK, EQUIP BD, BDD BACKDRAFT DAMPER ADJ ADJACENT BS BIRDSCREEN BSC BIOLOGICAL SAFETY CABINET DN DOWN CFH CHEMICAL FUME HOOD EA EXHAUST AIR CFM CUBIC FEET PER MINUTE OA, OSA OUTSIDE AIR DB DUCT BOARD RA RETURN AIR L,S LIQUID, SUCTION SA SUPPLY AIR N NECK (N) NEW NIC NOT IN CONTRACT (E)/EXIST EXISTING ON OUTSIDE AIR INTAKE (R) RELOCATED RD ROUND DIFFUSER BWG BOTTOM WALL GRILLE SHC SENSIBLE HEATING CAPACITY TWG TOP WALL GRILLE SR SUPPLY REGISTER TYP TYPICAL TC TOTAL COOLING VD VOLUME DAMPER VEL VELOCITY (�M DEMO WH WATER HEATER C=_) REVISIONS AIR TERMINAL LEGEND GRILLE, REGISTER, XX 8x8 -- NECK SIZE (INCHES) DIFFUSER IN LEGEND 140 SQUARE OR RECTANGULAR AIR QUANTITY (CFM) XX 8"0 ----- NECK SIZE (INCHES) 140 ROUND Air Quantity (CFM) ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS NO ARROWS INDICATE FOUR WAY PATTERN FIRE SPRINKLER HEADS TO BE FAST REACTION TYPE BY OTHERS. DESCRIPTION OF WORK: RECE'VED 1. INSTALL (1) NEW GAS UNIT HEATER AS SHOWN ON PLAN. INSTALL NEW CITY OF TUKWILA EXHAUST VENT THROUGH ROOF. MAR 2 4 2015 2. ROUTE NEW GAS PIPING SERVING UH-1 TO NEW METER (BY OTHERS). PERMIT CENTER DRAWING INDEX M-1 LEGEND & ABBREVIATIONS, VICINITY MAP, NOTES, SITE PLAN AND EQUIPMENT SCHEDULE M-2 ANDOVER BUSINESS PARK, BLDG 4, STE 606A - PARTIAL HVAC & GAS PIPING PLAN REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 2 City of Tukwl a BUILDING DIVISION �z,. �,.a� *txurn• � a�.arsos' Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230138 www.pacificaircontrol.com 0 w n 0 w Cn q 0 w NO. DATE DESCRIP110N 03/05/15 PERMIT ISSUE THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION. DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER DESIGNED BY GL IB DRAWN BY CHECKED BY IB GL SCALE PROJECT NO. AS NOTED T150305 DRAWING 77US LEGEND & ABBREVIATIONS VICINITY MAP, NOTES, EQUIPMENT SCHEDULES & SHEET INDEX SHEET NUMBER FI LEPATH : I:\constructton\Autocad EXECUTIVE PMK\lndover Executive Park 606 Industry Drivel 1 of 2 COPYRIGHT 02001 PACIFIC AIR CONTROL, INC. INSTALL NEW GAS METER (BY OTHERS) TO SERVE UH-1 IN STE 606A WHSE SPACE ; PRESSURE INLET — LESS THAN 2 PSI PRESSURE DROP — 0.5 W.C. SPECIFIC GRAVITY— 0.5 ROUTE (N) 3/4"0 GAS LINE (20' L) FROM (N) GAS METER TO UH-1 (30 MB INPUT) SECURELY SUPPORT NEW GAS LINE FROM BUILDING STRUCTURE PER IFGC 2012 407 REQUIREMENTS; CONNECT NEW GAS LINE TO UH-1; INSTALL SHUT—OFF VALVE AND DRIP LEG PER IFGC 2012 409 REQUIREMENTS UH-1 INSTALL THE UNIT HEATER IN ACCORDANCE WITH LOCAL BUILDING CODE, NFGC 2012, ANSI Z223.1 & MANUFACTURER REQ'S. SUSPEND THE UNIT 4' FROM ROOF FRAMING STRUCTURE WITH 3/8" THREADED RODS FROM THE THREADED NUT RETAINERS AND BRACE FROM BOTH HORIZONTAL DIRECTIONS (2—POINT SUSPENSION). N -� I•----- M - -I M and N - Hanger Dimensions for both 2-pt and 4-pt Suspension R - Hanger Dimension for - 2-pt Suspension P and 0 - — Combustion Hanger P Air Inlet Dimensions for 4-pt — R Suspension Thermostat REAR (4-pt is L TOP VIEW � Connection O VIEW required if !► (30-125 Vertical; installing 150-40o Horizontal) optional Q { 3/8"-16 Female Thread nozzle.) I _ all suspension points ine t Voltage ts K �'I External Inlet Vent Collar (For ( H Gas size, see Technical at circuit board) Connection Data in the APPENDIX on page 38.) e E 1.1 /4 ---------- F (32) RIGHT SIDE VIEW (Access Panel) 0 Model UDAP Dimensions (inches ± 1/16) Size I A I B I C I D I E I F I G I H J K I M N I P I Q I R 30,45 12-1/8 26-5/8 10 13-13116 26 21-9/1& 5-3/16 6-112 2-11116 3-7/8 17-3/8 11116 4-5/16 13 9-9/16 0)�,NIT UH-1 DETAIL NEW 4"0 UNIT HEATER COMBUSTION AIR EXHAUST, VENT THROUGH ROOF PROVIDE LOCKABLE THERMOSTAT AT UNIT HEATER HEIGHT ELEVATION FOR FREEZE PROTECTION 72-----------r -I.Il'"' \ WAREHOUSE AREA 1510 SF RR I RR` 1 RR I RR 1 —f I I 1 OPEN AREA I 1 I OFFICE OFFICE L---------------a 606 INDUSTRY DRIVE, STE 606A WAREHOUSE AREA OPEN AREA WAREHOUSE AREA :: OPEN AREA OFFICE 606 INDUSTRY DRIVE, STE 6068 606 INDUSTRY DRIVE, STE 606C NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A - PARTIAL HVAC & GAS PIPING PLAN SCALE: 1 /4" = 1' - 0" A nrA r%r- lAff% H/ El RE\AEVVED FOR CODE COMPLIANCE APPROVED 15 rila 1SION NCWP ANDOVER EXECUTIVE PARK BUILDING 4 KEY PLAN NTS . RECEIVED CITY OF TUKWILA MAR 2 4 2015 PERMIT CENTER Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230138 www.pacificaircontrol.com 0 LL- I-- U W tY a- I) W M 0 li W NO, DATE DESCRIPTION 0 03/05/15 PERMIT ISSUE Al THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER DESIGNED BY GL IB DRAWN BY CHECKED BY IB GL SCALE PROJECT NO. AS NOTED T150305 DRAWING 77US NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A — PARTIAL HVAC PLAN SHEET NUMBER FILEPATH: EXECUTIVE PARK\Andover Executive Park 606 Industry Drive 2 of 2 COPYRIGHT ©2001 PACIFIC AIR CONTROL, INC.