Loading...
HomeMy WebLinkAboutPermit PG15-0072 - 393 BUILDING / VACANT SPACE - SEWER CONNECTION AND GREASE MAIN LINESVACANT SPACE 393 STRANDER BLVD PG15-0072 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 ` Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 2623049064 Permit Number: PG15-0072 Address: 393 STRANDER BLVD Issue Date: 6/23/2015 Permit Expires On: 12/20/2015 Project Name: VACANT SPACE Owner: Name: REGENCY CENTERS LP Address: PO BOX 790830 C/O PROPERTY TAX DEPT, SAN ANTONIO, WA, 78279 Contact Person: Name: 10SHUA KLIMP Phone: (206) 678-2467 Address: 10118 428 AVE SE, NORTH BEND, WA, 98045 Contractor: Name: RETROFIT PLUMBING LLC Phone: (206) 930-5617 Address: 10118 428TH AVE SE, NORTH BEND, WA, 98045-9466 License No: RETROPC914CP Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: CONNECT TO EXISTING SEWER AND GRESE MAIN LINES UNDER SLAB, ROUTING TO NEW LOCATION FOR USE BY FUTURETENANT Valuation of Work: $5,800.00 Fees Collected: $181.36 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature:UAM Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: [n�"' � `�b°f7—�-- Date: Print Name: K t Ci io / , 1 no This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWIL Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 � lipe//www.TukwilaWA.Ro_y Plumbing/Gas Permit No. N� Project No. r _ Date Application Accepted: Date Application Expires: use PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION ,}� ,j, i ,Q King Co Assessor's Tax No.: q Site Address: ` 3 e, � �"'k , `yy` • Suite Number: '313 Floor: Tenant Name: 1 JA New Tenant: ❑ .....Yes EJ..No PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name:�e U 9 Address:2.- O Ci1y: t State: w ZipiqM Phone: F Email: Zf} (o 2 q l� Valuation of Project (contractor's bid price): $ 5goo. 00 PLUMBING CONTRACTOR INFORMATION Company Name: 44 l Address: /01/ (?Z � � City: Y State:Zip:, �S Phone: u)tl ow -Zq(D Fax: Contr Reg No.:.,-, � 1 C xp Date: Tukwila Business License No.: Scope �� of Work (please provide detailed information): CMG' hit eG�IJ � TD eY i X A' n i SAY A AX ot. J Yf0. S e. VVLAA^ U rae r S /,r-S y D mLt1 [ 0 C11 c7rt Y i/ S-L' fi �'+� ri/✓� t�`tGLn Building Use (per Int'l Building Code). - Occupancy (per Int'l Building Code): * Utility Purveyor: Water: Sewer: H: AMficationsTorms-Applications On L'ute\2011 ApplicationsTiumbing Pemrit Application Reviscd 8-9-1 Ldocr Revised: August 2011 Page 1 of 2 bh Indicate type of plumbing fixtures and/or gu.. piping outlets being installed and the quantity t—ow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water cooler r head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water I treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES- Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch 51 mm diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn Sprinkler system on any one meter including backflow protection devices Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Date: Print Name: VOSAVA, Day Telephone: �l�P �i -7, 2 I (07 Mailing Address: A-uc'- iJa d k q 90q City State Zip iil4pptieatiom\Forms-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $181.36 PG15-0072 Address: 393 STRANDER BLVD Apn: 2623049064 $181.36 PLUMBING $174.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $107.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $34.88 TECHNOLOGY FEE $6.98 TECHNOLOGY FEE TOTAL FEES PAID R000.322.900.04.00 0.00 $6.98 Date Paid: Friday, June 12, 2015 Paid By: JOSHUA KLIMP Pay Method: CHECK 2842 Printed: Friday, June 12, 2015 10:20 AM 1 of 1 j�' �S ��' l��Y57EM5 INSPECTION RECORD PG Z Retain a copy with permit 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Pr j ct: Type of Inspect, n: A dress: 1 ® ( Jd b Date Called: Speaa Instructions: �M Date nt a.m. VGA p.m. Requester: Phone No: Inspector: Date/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit f /5--O IN CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 roject: _ Type of Inspection: guess: ,rr (1� Date Called: Special Instructions: Date Wrtec ,_ r a.m. l J m. p Requester: Phone No: Inspector: 1Date- El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0072 DATE: 06/12/15 PROJECT NAME: VACANT SPACE SITE ADDRESS: 393 STRANDER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: /�-T AWL Building Division Fire Prevention ❑ Planning Division ❑ ASS NIA Public Works Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/16/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/14/15 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 RETROFIT PLUMBING LLC Page 1 of 2 Search L&I Hone Inicio on Espauiol Contact Safety kiWashington State Department of Labor & Industries RETROFIT PLUMBING LLC A-7. InClex. Help My Secure I.,&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 10118 248TH AVE SE KLIMP, JOSHUA JOHN NORTH BEND, WA98045 206-678-2467 Principals KING County KLIMP, JOSHUA JOHN, PARTNER/MEMBER Doing business as WA UBI No. Business type 603 321 598 Limited Liability Company Governing persons JOSHUA KLIMP License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction.Contractor. Active. Meets current requirements. License specialties PLUMBING License no. RETROPL853D4 Effective -- expiration 03/19/2015— 03/19/2017 Bond .....__........ American Contractors Indem CO $6,000.00 Bond account no. 100270971 Received by L&I Effective date 03/19/2015 03/13/2015 Expiration date Until Canceled Insurance ... . ........................ Ohio Security Ins Co $1,000,000.00 Policy no. BKS53790064 Received by L&I Effective date 03/19/2015 02/06/2015 Expiration date 02/06/2016 Savings .................. No..savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ........................................ No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603321598&LIC=RETROPL853D4&SAW= 6/24/2015