Loading...
HomeMy WebLinkAboutPermit PG15-0082 - CHEVRON - BATHROOM AND GROUND GREASE INTERCEPTORCHEVRON 14415 TUKWILA INTERNATIONAL BLVD EXPIRED 05110116 PG15-0082 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 0040000136 Permit Number: PG15-0082 Address: 14415 TUKWILA INTERNATIONAL Issue Date: 8/19/2015 BLVD Permit Expires On: 2/15/2016 Project Name: CHEVRON Owner: Name: APNA INVESTMENTS GROUP LLC Address: 26220116TH AVE SE #201, KENT, WA, 98030 Contact Person: Name: DAVID MALIK Address: 26220116TH AVE SE, KENT, WA, 98030 Contractor: Name: AFFIDAVIT - PARAS MALIK Address: License No: Lender: Name: Address: "I , DESCRIPTION OF WORK: RELOCATE BATHROOM PER BUILDING PERMIT D14-0346 Phone: (206) 841-3355 Phone: Expiration Date: INCLUDES INSTALLATION OF "ENDURA" MODEL #3907A02 - 7GPM ABOVE GROUND GREASE INTERCEPTOR. Valuation of Work: $1,000.00 Fees Collected: $348.02 Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Cj `�� Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit an agree to the conditions attached to this permit. Signature: '' Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKR I Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 litip://www.Tukwi]aWA.Rov 9 Plumbing/Gas Permit No. YJ Project No. Date Application Accepted: 1 J Date Application Expires: For o ice use only 1 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION I /� � _ I , , (� King Co Assessor's Tax No.: Site Address: I `"ITI 1 W (L �N ��' �� y8� L��b �11 0 Suite Number: Floor: Tenant Name: Gt w /ITV New Tenant: ❑ .....Yes�f-7No PROPERTY OWNER Name: 11 mT l--h�-���1-� r�l I , `l, V r J Address:/ Otto`1 �J-Z"ip� City: �/r-t'1DT State: - CONTACT :PERSON — person receiving all project communication Name: T) V o lJ '�/j Address: d° ,6 AAA l � 6 / )) AV Cl\1 -L City: r-,-7�� Stater q Zip!9ev3 () Phone�V � ��. (.�?'�ax: /�.1t Email: rkL �IC1,(� �L(I Iy .-_ K WA PLUMBING CONTRACTOR INFORMATION Company Name: r ^, r-- C/ / i Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: to , Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or piping outlets being installed and the quantit, .;low: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain ' Shower, single head trap Sinks 3 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 I gallon capacity) Each�additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric- 1� type vacuum breakers 2` inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective 'device other than --- `atmospheric-type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain ` Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas , Each lawn sprinkler System on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). _ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AGENT: Date: / f Day Telephone: C' b Mailing Address: v�o If 6T7) S z City ­7�� o / - Kowl- 'M� 9�o3a State Zip H:Wpplications\Forms-Applications On Line12011 ApplicationsTlumbing Permit Application Revised 8-9-11.docx Revised: August2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $348.02 PG15-0082 Address: 14415 TUKWILA INTERNATIONAL BLVD Apn: 0040000136 $348.02 PLUMBING $334.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $235.20 PLAN CHECK FEE R000.322.103.00.00 0.00 $66.93 TECHNOLOGY FEE $13.39 TECHNOLOGY FEE TOTAL$348.02 R000.322.900.04.00 0.00 $13.39 Date Paid: Tuesday, July 21, 2015 Paid By: DEVENDRA MALIK Pay Method: CREDIT CARD 09078D Printed: Tuesday, July 21, 2015 3:04 PM 1 of 1 .�j �R' I���SYS7EM5 W z ) (ti Z � = � on.a c*ls o JUL'23 •-+ o Z TUKV Ua cam,— PUBLIC) CL 53'-3 1/4" 38'-6 1/4" M I I6'-10` NEW 2x6 WALL i �2 NEW 3¢6=� E31Q RELOCAA TED COOLER RM >< 104 \ 152.4 SF RM a 101 D N W T KIN A FA rF� EXIST. COOLER RELOCATED I�'O NEW STOGKINC AREA a TO TH15 LOCATION 8q.5 SF. SIMP�SON HUG612 HANGER EXIST. \ SIMPSON (,.a RANGE NEW bx8 i '¢ H.F.-2 BM. '—} E EXIST. /' `\ E E AVE \� 3¢ � --7—�IEW.6Rf----�IEW7RIP----- ---COL MNS L --- �XI�T. SE'r�EirLlFl LINh EX15TIN6 T H.F.-I BM. H.F-I BM. RM N105 WATER Tf NK NEW 6.10 RFI -102 O EXIST. OFFICE H.F.-I BM. Q N WN ACTH 51.0 SF R -101 48.T5 SF. NEW EXIST. \I NEW ABOVE 3¢6¢ GROUND GREASE INTERCEPTOR I T v i NEW FLOOR DRAIN HEW SINK 3-COMPARTMENT m \ E3¢T \ Qm \ EXI5TING NEW GLEAN OUT HAND SINK RM a106 O ry RM -100 NEW PREP AREA ry FX15T. SALES 85.0 5F w v a 1 2420 5F w � I I I I O I I I I I I I EXIST. E E E E 5¢ I OEJ I 20'-l" 3'-8" 10'-O"10'-O" 3'-9" JUL1 46'-9' J 62'-O" rtFiMl PCB 19 0082 VED 2015 tALA NORKS -%ii ! � TUKWILA 21 2015 CENTER [FCl�[9 GREASE INTERCEPTORS lLU CC LU Uj r l/1LU Q f _p i H V w Ln V) J a. z u Engineering grease manag solutions for plumbing and food service professionals Rt , 1 4 201 .,,:try gfTukwila BUILDING DIVISION CORRECTION! LTR# RECEIVED 'AUG 1' 1201a TUMR-A LIC WORKS RECEIVED CITY OIL TUKWILA AUG 10 2015 PERMIT CEIVTF 0 0 2,vt - _ an 0A11aX; Canplas is one of North America's leading producers of plastic products for the building and construction Industries and part of the Aliaxis Group of Companies. Specializing in injection moulded products, Canplas has five decades of expertise and experience in the manufacturing and distribution of plastic plumbing products, processing multiple materials and producing millions of fittings and products on an annual basis. Endura grease interceptors have demonstrated effective, efficient and consistent performance with over a decade offield installation and operation. Endura is a multi -patented product builtto withstand the toughest environments and provides the flexibility of in -floor, on -floor and semi -recessed application. Canplas has been instrumental in changing the traditional practices regarding the installation of grease management solutions, plastic alternatives to metal interceptors being now substantially accepted Nationwide as the new standard for grease management in commercial foodservice applications. Grease Interceptor Series Canplas Earth friendly solutions for Grease Management 3907AO2 - 7GPM (0.44 LPS) 2" (51 mm) connection Canplas is committed to the continuous 391 OA02 -1 OGPM (0.63 LPS) 2" (51 mm) connection improvement of our environmental 3915A02C -15GPM (0.94 LPS) 2" (51 mm) connection performance and to meeting or exceeding the Compact models use a development of the patented Canplas baffle system to enhance requirements of all applicable environmental laws and regulations. separation performance at low flow rates. EZ-(Iean tank design —Aids exterior cleaning. our manufacturing process waste and office waste Economizing In our use of water _ 3925A021.0 25GPM 0.6 LPS) 2"(51mm) connection Endura* Lo-PRO for tight on -floor applications where space is at a premium. '- and energy to maximize Same dimensional footprint as 35gpm and 50gpm Endura' models. ` Overall height 11 inches, still meeting requirements of ASME112.14.3. Internal components can be removed in less than 6"of additional clearance. a processes that helps protect the environment it 3920A02 20GPM (1.26 LPS) 2" (51 mm) connection 3925AO2 25 GPM (1.6 LPS) 2"(51mm) connection - Continual ; : refinemerrttomaximizeeffidency 3925A03 25 GPM (1.6 LPS) 3"(76mm) connection ,' .r - while minimizing waste Our original tank, 20-259pm units are perhaps the most commonly installed product ' + *' Both 2"and 3"connections suit on -floor and in -floor application respectively. • Fewer installations and replacements result in lower lifetime costs & less landfill waste. • Injection molded in engineered thermoplastics, Endura Grease Interceptors 3935AO3 35GPM (2.2 LPS) 3" (76mm) connection will not corrode, chip, or peel, even underthe r 3935AO4 35GPM (2.2 LPS) 4" (110 mm) connection most severe Applications. " Structured foam molding technology provides rigidity and durability • Durability provides consistent operation — no ir" while reducing unit weight. Diffuser baffle aids separation at increased compromise of effectiveness due to 1w' flow rates. deterioration of key parts • Light -weight grease �'"`**► 3950A03 50 GPM (3.2 LPS) 3" (76 mm) connection interceptor units enable alk smaller carbon footprint and 3950A04 50 GPM (3.2 LPS) 4"(110 mm) connection low -emissions transport f A tall version of our 35gpm model the 50gpm interceptor uses common • Injection molded 4 parts incorporating all the best features of the Endura product design in thermoplastic requires less energy to produce 4 a comparatively light weight solution to that of its metal competitors. than metal grease interceptors • Endura interceptors are manufactured a minimum of 5% recycled material. -2- The Grease interceptor industry has developed significantly in the past decade with not only more advanced and improved products but also development of performance standards and harmonization of common terms and references. Traditionally the term "Grease Trap" was commonly applied and is still used in the industry today. This term is progressively disappearing from nomenclature and technical references based on an industry wide recognition that theterm trap"wouldsuggestthe presence of a water seal, integrally located within the interceptor. This practice substantially teased many years ago, modem interceptors being designed to be installed in conjunction with external water seal traps as a standard part of the system. In addition to this clarification, with publication of the 2006 UPC plumbing code three generic types of Grease Interceptor were introduced and have since become the industry standard for designating the type of interceptor being considered. Generically the appOcadon of a Grease Interceptor regardless of type is defines as follows: Grease Interceptor: A plumbing appurtenance or appliance that is installed in a sanitary drainage system to intercept nonpetroleum fats, oil, and grease (FOG) from a wastewater discharge. Specific characteristics then define the three types of Interceptor: Hydmmechankal Grease Interceptor (HGQ "An HGI is sized by flow rate (GPM) and qualified separation/retention efficiency, validated against National performance Standards. An HGI incorporates a defined means of flow control, acts to entrain air to influent includes interior baffling, or barriers in combination or separately, working to promote hydromechanical separation. HGI's are generally installed inside the facility they serve." Gravity Grease Mtetce W (GGQ "A GGI is characterized by volume, minimum 30 minute retention time, baffle(s), not less than two compartments, a total volume of not less than 300 gallons (1135 Q, and gravity separation. If not recognized by an official body, a GGI will be designed by a registered professional engineer. GGrs are generally installed outside the building they serve and buried below grade." Grease removal Device (GRID) AGRD is a hydromechanical grease interceptor that mechanically removes non -petroleum fats, oils and grease (FOG) from the separation chamber, the control of which is either automatic or manually initiated and involves maintaining liquefied state of intercepted FOG by heating. GRD's are installed inside the facility they serve.." •; ; r v PDI G101 - PDI G101 None PDI G101 . -(SA B481 - (SA B481 - CSA B481 -ASMEA112.14.3 -ASMEA112.14.3 -ASMEA112.14.4 UPC -UPC UPC(500USG+) UPC - IPC - IPC IPC (300 USG+) IPC NPCC NPCC -NPCC NSPC NSPC NSPC y. Typically Not Typically Not Yes Yes Plastic (PP- Polypropylene) - Cast iron - GRP/Fiberglass Stainless Steel - Epoxy Coated Steel - Concrete - Plastic (PE) - Steel 93%-99% -Based on ASME Min 90% (based on Performance No Assessment Possible Min 90% (based on Al12.14.3 - Tested to breakdown Standards) Performance Standards) r A` = Min 20 years -Typically life of -Cast Iron (10-15 yrs) GRP/Fiberglass (20Yrs+) -Tank (10Yrs+) system - Epoxy Coated Steel (3-5yrs) - Concrete (8-10yr5) -Mechanical (1-3yrs) - Plastic (PE) (20yrs+) Steel (7-12yts) Yes with Accessible flow control Yes (Required for PDI compliance) No Yes 1 .9 -1.5 8-10 6-8 8-10 0S-1 z= 1 1 Min 10 1 Flow Rate Flow Rate Capacity (US Gallons) Flow Rate On -Floor -2-3hrs -On-Floor -2-3hrs 12-15hrs 2-Ars - In Floor - 4-6brs - In Floor - 4-8hrs Licensed Plumber - Licensed Plumber - Licensed Plumber/ Groundworker - Licensed Installer - Common tools/practices Common tools/practices - Earthmoving/Excavation - Common tools/practices u ; Licensed Plumber - Licensed Plumber - Licensed Plumber (Hook Up) - Licensed Plumber - Ground worker (install) - Licensed Electrician - Stock Item - National/Reglonal/ - National/Regional/ Local Local/Regional Manufacturer Direct - Manufacturer Direct - Local Local Plumbing Wholesale Plumbing Wholesale - Special Order-Regional/Local Representation - Restaurant Equipment - Restaurant Equipment Plumbing Wholesale Distributors Distributor -3- Grease Interceptor .. Model Chart Compact tank / small footprint 7 GPM 3907AO2 - 2" Minimum of 5% ;;. Injection molded in proven 10 GPM 391 OA02 - 2' .� engineered thermoplastics for 15 GPM 3915A02C - 2' _ strength and durability OUTLET INLET ' i EZ-Open cover latches 7A i a Odor lock cover gasket - EZ-Qean exterior tank profile with a non -ribbed section at the lower two 7GPM3907A02 inches of the tank using lohncouPgngs -10 GPM 3910A02 10 Year limited Manufacturers allowing for use of various 15 GPM 3915AO2C Warranty piping materials MATERIAL VFOR NEVEN SUPPORT WSORBENTOF TANK Injection molded in proven - 20 GPM 392OA02 -Y Minimum of 5% _ engineered thermoplastics for -25 GPM 3925AO2 - 2" strength and durability 25 GPM 3925AO3 - 3' r? EZ-Open cover latches OUTLET ; INLET Oda lock cover gasket i Load rated cover supports up to 440 Ole I m pounds of pedestrian and light duty -, traffic Connected using 20GPM 3920A02 25gpmwith 2"or3'connections mechardaijolmncauplings 25 GPM3925AO2 allowing for use ofvadois 25GPM3925A03 10YearLimitedManufacturers pipingmatMals. LEVEL, NON -ABSORBENT Warranty MATERIAL FOR EVEN SUPPORT OF TANK 11"in height, ideal for under sink - 25 GPM 3925AO210 - r Minimum of 5% installation Requires only 6'of clearance for wr fl y maintenance i Injection molded in proven engineered k (I.ET �. INLET thermoplastics for strength and durability - EZ-Open cover latches Connected using Oda lock cover gasket mechanical joint coupikgs EZ-Clean tank exterior allowing for use of various piphg materials. LEVEL, NON -ABSORBENT 25 GPM 3925AO2LO 10 Year limited Manufacturers MATERIAL FOR EVEN SUPPORT OF TANK Warranty ip Injection molded in proven engineered - 35 GPM 393SA03 - 3" Minimum of 5% thermoplastics for strength and 35 GPM 3935A04 - 4" durability EZ-Open cow latches -Odor lock covergasket r OUTLET INLET Load rated k over supports up to 440 r pounds of pedestrian and light duty 1 traffic Connected using _ mechanical joim couplings 10 Year Limited Manufacturers allowing for use of various Warranty piping materials. - 35 GPM 3935A03 Supplied with 2 piece flow control MATERIA L FOR EON -ABSORBENT SUPPORT OF TANK 35 GPM 3935A04 - 50 GPM 395OA03 - 50 GPM 395OA04 Injection molded in proven engineered - 50 GPM 395OA03 - 3" Minimum of 5% thermoplastics for strength and 506PM 395DA04-,r durability EZ-Open coo latches Oda lock covergasket Load rated cover supports up to 440 pounds of pedestrian and light duty traffic Connected using 10 Year Limited Manufacturers mechanical joint co ings allowing for use of various Warranty plying materials. - Supplied with 2 piece flow control '-- LEVEL, NON -ABSORBENT MATERIAL FOR EVEN SUPPORT OF TANK 4 # 1 t" q,it S m' YfRF MAR. A '6l# yy t y # T CONCRETE FLOOR NYC 3•Part Master. - Commonwealth Format of Massachusetts Spedlortions, G-101 CAD dmftp r_ t & DIM drawings • H Continuous available at ° N/A N/A B481.1 �S discharge at /� �y`�� hty, 104'C(220'F) ! V�V V :com A' »Z.,4E w��waa Instaflatlon Guide availableat •Cheddocalcodesfaracceptanceofin-floor!mUAation °P� ina� • Finish to floor level awrimodating requisite materials, E.G.Tde, mortar, etc Excluding 7 GPM CONCRETE FLOOR MODULAR EXTENSION RISER AVAILABLE ----� --- / .. 0. NYC Commonwealth 3-Put Master Fornwt c101 of Massachusetts specMations, CADdmwimgs & DIM drawings { • - Skmidtfxrmoddemy, +l�• B481.1 *y Continuous dischargeat availableat nRCfi.com allows auesstoIn-now lowallitrddwke E ti3— r....w.f 104'C(220'F) 6°111lOd" riser Custom length of SDR 35 orSDR Al12.14.3 Measurement markings Stackableupto3sets (18"Total) 28 sewer Pipe to be used for access sleeve P� Guide available at entknkroerceim.com •Rmshtofkwrlevel accommodatin requisite g -3920AX6 392 -r2o3w,6^SOR35/28 materiah E.G.Tde,mortar, etc sewerpipedametu NYC 341'art Master S Commonwealth Format G-101 of Massachusetts Spedfiations, CAD drawilings On -Floor & BIM drintrimp Ittstallatlon Only N/A N/A11 L Continuous discharge at available at r. `. 104'C (2207) ARC V .com A712.14.3 Installation Guide available at endurainterceptacmn CONCRETE MODULAR EXTENSION FLOOR---- F RISER AVAILABLE cur yS,'` �G�i•G c101 NYC Commonwealth of Massachusetts 3-Part Mister Format SPodfic+Hons. _ --------- y ' UDdrawimgs & DIM drawings s�° Continuous available at — shekitagowsaaxssto B4e1.1 3 discharge at 104'C(220-F) / RC V.com r III flow an" device ofSDR " "'°"• 6' Modular dser Custom length 35 or SDR 28 sewer pipe to be used for A112.14.3 Insteilatlon Measurement markings Stackable up to 3 sets (I rTotal) accessslem -r39=w,6•sDR35/28 °po Guide available at endurakie eptOLCom •Rnishto floor level aaanmodaVing"Me -3935AX6 sewer pipedmrreter materleb,EG.T8e,nwWe1L -4"392201 WSDR35/28 sewerpipedameter MODULAR CONCRETE EXTENSION FLOOR RISER AVAILABLE ' G-101 ° NYC Commonwealth of Massachusetts 3-Part Master For1118t Spedf cadons, CAD dravdmgs --- s, n & DIM drawings 8481.1 Continuous discharge at available at p�'�A'�'' 9@-etdtallmawmto 2 4E 104 d rModulardser Measurement markings Stackable Lip to sets (18"TotaO hs•B 06we nvofdeNce Custom length of$DR 35 orSDR 28sewerpipetobeusedfa amess- sleety A °pa . InsWlation 6ulde available at endlmaktteroeptorcan • Rnish tofktmrlevel accommodating requbite 3935AX6 -r392203w, 6-SDR35/28 sewer pipe dameter -4"39220ew, 8"SDR35Ra materials, LG.Tile, mortar, etc sewer pipe dameter 3907AO2 - 7GPM (0.44 LPS) 2"(51 mm) connection 391 OA02 -1 OGPM (0.63 LPS) 2" (51 mm) connection 3915AO2C - 15GPM (0.94 LPS) 2" (51 mm) connection Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2'INLET/ OUTLET MODELS 3920A02 20GPM (1.26 LPS) 2" (51 mm) connection 3925AO2 25 GPM (1.6 LPS) 2" (51 mm) connection 3925AO3 25 GPM (1.6 LPS) 1 1 m 3"(76mm) connection CIL Notes: D Dftnenslan: ACCESSIBLE FLOW CONTROL 3920A02:12.9" 3925A02:12.8' DEVICE (FCD) IS SUPPLIED FOR 3925A03:12.2' INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2" or 3" III TOP VIEW INLET REINFORCED XYPROPYLENE COVER ONE-PIECE TANK ISO VIEW 17.5' FRONT VIEW SIDE VIEW TOP VIEW 23.6' INLET REINFORCED POLYPROPYLENE tj., COVER ONE-PIECE TANK 150 VIEW 17.5" ff C c C Dimemlon- C I 392OA02: 3.5' 9 39.25AO2: 3.5' 9 MM03:4.1' INLET/OUTLET MODELS FRONT VIEW SIDE VIEW Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2" INLET/OUTLET MODEL LATCHES 2: REINFORCED it POLYPROPYLENE COVER INLET J _�` ONE-PIECE vzz==TANK TOP VIEW ISO VIEW OUTLET I 31" INLET 4" T_ 7 FRONT VIEW SIDE VIEW -6- I 31 3935A03 35GPM (2.2 LPS) 3"(76mm) connection 3935A04 35GPM (2.2 LPS) INLET 23.5" .aa...a..a.a...a.aa...a..... ooe.o.00000000eo..000000..00 p000000a0000000000.00.000000 4"(110 mm) connection 000000.0000.o.00aaoa0000000 e0.00000000e.000.00000000o aa. 0000 O............ o 000. o0 o00000000o0000000000 ... ............... o000000 000 000000000000000000000 00000000.000000000000. 00000000000000000000 00 000000000000000000000 Notes: ACCESSIBLE FLOW CONTROL TOP VIEW 150 VIEW DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM � 31"� �--23.5"---� OFTHE GREASE INTERCEPTOR (GI) OUTLET -3"or 4" INLET/OUTLET MODELS INLET 12.5" 1 �I F--- 29" 1 FRONT VIEW SIDE VIEW REINFORCED ERROPYLENE ?-PIECE IK REINFORCED 31LATCHES POLYPROPYLENE %�— COVER ----------------- o..........000000000000.000 / �. °.o .00.000000..o000 ..00.000°oeo°000000000000e0000 ° e.o 00 ..... Ooo....000 e.°aaaa o.000000000.000.o 0o00O0 00000000000.. O 0......0 .. -.. 0000000000000000,00000000 00000 000 0.0.00.000o....aaa INLET 230 0°000000000000000°OOOOOOOO .5 o°a.....a...aaa....a.a.0...a 3950A03 50 GPM (3.2 LPS) ° °°°°°° . 00.0000000000000000000000° 00000000000000000000000000 0000000000.00000 000. 3" (76 mm) connection °°°°°°°°°°°°°°°°°°°°°000ao a o oo00000000eoo.0000.000 ao. 0000000000.00000000000000000 e000000000000000000 .. ........ 0000e00e00000000 3950A04 50 GPM (3.2 LPS) 4" 010 mm) connection TOP VIEW 31'� Notes: OUTLET —' — INLET ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM 2 OF THE GREASE INTERCEPTOR (GI) 18.5" -3" or 4" INLET/OUTLET MODELS FRONT VIEW ISO VIEW f --- 23.5" SIDE VIEW NE -PIECE \NK -7- Sizing For Endura models Canpias recommends sizing by flow rate. The use of a flow control with a Hydromechanlcal Grease Interceptor is considered mandatory. Without a properly sized flow control, the discharge rate through into the interceptor may exceed the design rating of the unit, causing lower efficiencies and increase the risk of grease, passing into the downstream system. Be careful not to confuse liquid capacity and flow rate. Liquid capacity is stated in gallons (or liters) while flow rate is referenced in gallons per minute (gpm) or Usec. If sizing based on a 1 minute drain time indicates that a higher flow rate Interceptor is required, there are two options. 1. Use a larger interceptor to accommodate full accommodate the flow of the Imin drain down 2. Use a 2 min drain time in your calculation Floor Drains & Floor Take the volume of water produced by the number of hose bibs (ie 1.5-2.0 gpm per 3/4" faucet) Note. if using a 2 minute drain time this will cause the interceptor to be 50% of the original number calculated. Although a smaller unit will be less expensive, the lesser r physical grease capacity will dictate an increased frequency of cleaning. � ' Sizing Calculator Visit our website for our easy to use online GI Sizing Calculator. www.EnduraGiCalculatorcom A Procedure for Sizing InterceptorsTable Grease STEP FORMULA EXAMPLE 1 Determine cubic content of fixture by multiplying length x width x depth A sink 24"long by 20"wide by 12"deep. Cubic content: 24 x 20 x 12 = 5,760 cubic inches (61.0 x 50.8 x 30.48 cm3 ) 2 Determine capacity in gallons. 1 = 2 1 inches Contents in gallons: gallon cubic 5,760 / 231 = 24.9 gallons (94,451 A2 / 1,000 = 94A5 litres) 3 Determine actual drainage load. The fixture is normally filled to approximately 75% of ca achy with water as the items being washed displace about 25% Actual drainage load: 75 x 24.9 =18.7 gallons (0.75 94.45 70.84 litres) of the total fixture content. x = Actual drainage load = 75% of fixture capacity 4 Determine flow rate and drainage period. Calculate flow rate for one minute drainage period: In general, good practice dictates a one minute drainage pe- riod; however, where conditions a two minute drainage 18.7 11 =18.7 g.p.m. flow rate 1 permit, period is acceptable. Drainage period is defined as the actual (70.84 / min. = 70.84 Lp.m.) Calculate flow rate for two minute drainage period: time required to completely drain the fixture. 18.7 / 2 = 9.4 g.p.m. flow rate Flow rate =Actual Drainage Load (70.84 / 2 min. = 35A2 I.p.m.) Drainage Period 5 Select Interceptor. For a one minute drainage period: From Table B select the interceptor with a flow rating at least equal to the calculated flow rate. When the calculated flow rate 18.7 g.p.m. (70.84 I.p.m.) flow rate = 20 g.p.m. G.I. For a two minute drainage period: falls between two sizes, select the larger of the two 9A g.p.m. (35.42 I.p.m.) flow rate =10 g.p.m. G.I. interceptors. Table C PrOUdUre PDI Size Symbol for Sizing 4 Grease 7 Interceptors 10 15 20 25 35 50 Flow Rate US Gallons per Minute (GPM) 4 7 10 15 20 25 35 50 Flow Rate Liters per Second (LPS) .25 .44 .63 .95 1.26 1.58 2.20 3.16 Grease Capacity Pounds (Lbs) 8 14 20 30 40 50 70 100 Grease Capacity Kilograms (Kgs) 13.63 16.35 19.07 113.61 118.14 122.68 131.75 145.36 -8- PM Rating (GPM) 7 1 10 15 20 25 LO 1 25 35 50 Capacity - min. (Ibs) 14 20 30 40 50 1 50 70 100 litres Per Second - (LPS) 0.44 0.63 0.94 1.26 1.6 1.6 2.2 3.2 Capacity -(Kg) 6.35 9.07 13.6 18.1 22.68 22.7 31.8 45.4 Endura Part Number 3907A02 391OA02 3915A02C 392OA02 392SA02LO 3925A02 (2-) 3935A03 (3") 3950A03 (3") 3925A03 (3') 3935A04 (4") 395OA04 (4') Average Effidemy % (ASME All 12.14.3) 95.5% 92.5% 92.0% 95.4% 97.1% 92.5% 98.6% 93.9% Actual Grease Capacity Uis (Kg) 31.95 (14.49) 33.1(17.28) 3497 (18.58) 76.4 (34.65) 53.4 (24.22) * 74 (33.6) 1385 (62.8) * 122 (55.3) 0p Wl g TemWratureCapaWies 2107 2207 2201 2207 2207 2207 2207 220' F (104'0 1 (104'Q (104'() (104.0 (104'Q (104"C) 004'{) (104Y) Cover Lead Capacity 440lbs 440lbs 440lbs 440lbs 440lbs 440lbs 440lbs 440lbs (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) Unit weight Capacity (Empty) 15.8Lbs 15.8Lbs 15.8Lbs 23 Ibs 23.9 Ibs 23 bs 45 bs 601bs (7.17kgs) (7.17kgs) (7.17kgs) (10.4 kgs) (10.85 ) (10.4 kgs) (20.4 kgs) (27.2 kgs) Liquid Capacity 12.96 gal 12.96 gal 12.96 gal 21.6 gal 18.9 gal 21.6 gal 39.4gal 52.0 gal (49.06 L) (49.06 L) (49.06 L) (81.8 L) (71.54) (81.8 L) (149.1 L) (1971.) Connecdonsin (nominaq 2" 2" 2' 1 2' _F­2` 2"(3915A02) 3"(393SA03) 3"(3950A03) 3"(3925A03) 4`(3935A04) 4`(3950A04) Capacity based PDI G101 minimum requirements for respective GPM rating at ASME A112.14.3 Breakdown. Actual Grease Capacity recorded at Breakdown of ASME A112.14.3 test 1 Piece Compact Flow Control Row Control & Air hitake Combined Connection Compact tron Pipe 5ize (Solvent weld) rh x h B L�111 A A 3.94" 000mm) 8 3.44" (87.4mm) C t D , 2 Piece Flow Controls (3"Version Illustrated) R w Control Body Air Intake Tee Connection Iron Pipe Size (Soiventweld) Yhxh 3'hxh 4"hxh r e _ a I 4i Iffi I (.7mm) 3"spgxh 4"spgxh A 3" (76.2mm) 4.23' (107.4mm) 6.13" (155.7mm) 2.67" (67.8mm) 3.19" (81mm) 8 3.84" 5.93' 6.84" 4.01" 5.04" (97.5mm) (151mm) (173 <-A .A (101.9mm) (128mm) C 2.27" 2.72' (57.7mm) (69.1mm) Installation "np las interceptor is supplied with full Installation and operation instructions.ation, Use & Care manual Is available for reference atdv:!" WARNING! DO NOT PRESSURE TEST. RISK OF SERIOUS INJURY. As a gravity fed plumbing appurtenance, a grease interceptor MUST be isolated from the drainage system in the event that final drain testing or other system pressure testing is required by the AFIJ. A Venting - Grease Interceptors must have a vented waste, sized in accordance with local code requirements for venting interceptors to retain a CAUTION water seal and prevent siphoning. Most codes dictate that two vents be installed, one upstream and one downstream of the grease interceptor. The upstream vent must not be placed between the air intake and the grease interceptor. ASystem longer .than 8 feet? - If more than 8 feet (2.4 m) of fall exists between appliance outlet and interceptor inlet, a secondary flow control must be installed immediately CAUTION preceding the grease interceptor to maintain flow velocities in the system. See installation drawing. Installed under a sink - If installed under a sink or similar obstruction ensure there is sufficient clearance to remove • the baffles for cleaning and maintenance. Clearance of 21" CAUTION for 50 GPM models, 5" for LoProfile model, 15" for all other models. If this is not practical, semi -recessing the tank may be an option. Floor Drains - Some local jurisdictions require that the interceptor service the floor drains. The floor drain must bypass the flow control to ensure the restriction does CAUTION not flood the drain. Therefore, the flow control should be installed as close to the fixture as possible or directly preceding the floor drain connection. -9- Installation All Endure Grease Interceptors are manufactured with standard no flub connections to accept locally approved/accepted MJ (Mechanical Joint) couplings. This method allows resilience in the connections to prevent stress and a flexible means of integrating metallic or plastic plumbing systems. Should adaption of pipe connection be required, use appropriate mechanical joint reducers but do not allow decrease pipe diameter across the unit. (i.e. 3 inch inlet, 2 inch outlet.) Due to regional and local code variation, models with threaded connections (FPT) are available by adding suffix'T'to the part number. Both tank and flow control (TFCD) will be supplied with FPT connections in this instance based on the respective nominal pipe size. Likewise Endura Interceptors can be supplied with spigot format flow controls (SFCD) by adding suffix'S'to the part number. Please Note: Solvent cement is not an acceptable jointing method from the piping system to the interceptor. This will result in leakage. The flow control device furnished with the Endure Grease Interceptor is essential to the proper operation of this unit. The flow control limits the unit to its rated capacity allowing enough time for grease separation to take place inside the interceptor. The flow control fitting is molded in PVC and must be solvent welded using PVC or PVC/ABS transition cement as appropriate. it is to be located in the drain line beyond the last connection from the fixture and as close as possible to the underside of the lowest fixture, see page 6-7 for typical installation. When the discharge from two or more sinks or fixtures are combined and served by one interceptor, a single flow control fitting should be used. The flow control device can be recessed into the floor if required and extension sleeves are available to complete a good finish at final floor level. Compact -� Version —,r &am*3922125C bblilmilMub Version le:3933125 2piecrfortnat -3'Wrrodels (2"availabk) • Flow direction spigot Version - - bx rnI3933125S & mut o -3r -3"&models (2"available) • Flow control orifice Threaded Venlon *; Exam*39331257 2 piece forrRat I-3"&rmodels �f (2"availade) The installation of a ball valve upstream of the flow control is recommended. A ball valve provides a means of drain line isolation for maintenance. Some local plumbing codes require that grease interceptors have an internal flow control to ensure drain lines do not bypass the grease interceptor. However, if the flow control device is located immediately upstream of an interceptor, this is often considered as forming part of the interceptor. Therefore, officials having jurisdiction may accept such design as meeting the intent of the requirement. If local codes dictate the flow control must be installed directly preceding the grease interceptor inlet, and the fixtures being served are in excess of 8 ft (2.4 m) from the interceptor, we recommend a second flow control being installed as close to the last fixture as possible. Please contact your local representative if you require further clarification. AIR INTAKE • Preferred Installation • 6ptionall Id floor Some local jurisdictions require warewashing installations to be made on an indirect basis incorporating an air gap. An air gap prevents back up of contaminated water into the sinks/appliances in the event of a system back flow.The flow control device must be incorporated before the indirect connection to prevent overflow occurring during high/maximum waste water discharge. If an air gap is located within 6" of flow control device*, installation of the air intake tee is optimal. (*Verify with Authority Having Jurisdiction) AIR INTAKE •TightEndosures 4y- • Flow Control DeAce Gap/ Air Break -10- Installation 3 4 3 6 6 7 • UNIX 2 5 = j � Do Not Exceed 25 ft (7.6 m) O• Flow Control Device © • Vented Waste © • Sink © • Grease Interceptor Q • Air Intake Q 0 Minimum Clearance 15 /2l" QCAU71ON: CLEARANCE REQUIRED 15"clearance (21"for 50 GPM model) to remove the baffles for CAUTION cleaning and maintenance. O• Flow Control Device © • Semi Recessed Option © • Grease Interceptor O • Sink © • Vented Waste 0.0 Minimum Clearance 15"/ 21" Q• Air Intake QWhen backfilling in -floor, the interceptor must have both the cover fitted and be filled with water to the inket/outlet level. This will ensure the tank itself will not move during backfilling, CAUTION pouring and/or floor finishing. When backfilling in particular, care should be taken to do so evenly around the unit and with light manual pressure only. QEnsure that the interceptor is clearly identified to flooring contractors to prevent it from being covered with flooring CAUTION material. Taping cardboard to the cover is generally effective. QCAUTION. CLEARANCE REQUIRED 15"clearance (21 "for 50GPM model) above the grease interceptor CAUTION is required to remove the baffles for cleaning and maintenance. 6" Modular risers available where deeper installation Is necessary to accomodate existing drainage. - Stackable up to 3 sets (18"Total) . , 3920AX6 (20/25gpm) and 3935AX6 (35/50gpm) The Endura Lo-PRO is installed on floor. Ensure you design/locate the grease interceptor so as to allow for maintenance. Placement should allow the cover to be easily removed for cleaning. A minimum clearance of only 6 inches is required above the top of the Grease Interceptor to allow removal of the internal baffles for a complete cleanout. QCAUTION: CLEARANCE REQUIRED 6"clearance above the grease interceptor required to CAUTION remove the baffles for cleaning and maintenance. O• Flow Control Device ©A •Vented Waste `7 •n Minimum Clearance 6" Cleanout maybe required in some jurisdictions © • Grease Interceptor O• Air Intake O • Sink - 11 - * If more than 8 feet (2.4 m), a *8 ft• secondary flow control must be installed preceding the grease interceptor to maintain flow velocities in the system. • Fork Lift, Pump Truck Traffic Area Do Not Exceed 25 ft (7.6 m) Do Not Exceed 25 ft (7.6 m) ✓0 Multiple Fixture Installation One interceptor serving multiple fixtures is recommended only when the fixtures are located close together (max 25ft of developed pipe run). In such installations, each fixture should be individually trapped and back -vented. O• Flow Control Device © • Grease Interceptor © •Vented Waste O• Air Intake © • Sink AProvision of a concrete pit with a load rated access cover will be required where pump CAUTION trucks of fork lifts travel. 0 • Flow Control Device © Grease Interceptor © • Hanger (Supplier by installer) O• Concrete pit Q• Vented Waste G• Air Intake O • Sink Q• Load Rated Access Cover A Due to the degree of risk and potential liability for the installer, great care must be taken in designing a hanger system. Canplas recommends consulting CAUTION an engineer before installing in this manner. Q• Flow Control Device © • Vented Waste © • Grease Interceptor O . Air Intake .� • Hanger (Supplier by installer) O • Sink QHanger must accommodate min. 541 Ibs (246kg) plus safety. CAUTION -12- Specifications SPEC NOTE: See www.arcat.com website for Microsoft Word (editable) document. SPEC NOTE: Canplas LLC and Canplas Industries Ltd. are members of the Aliaxis Group of companies, a global leader of plastic solutions for fluid transport in the field of building materials. The Aliaxis Group provides products for both residential and commercial building markets, in new build and renovation segments, as well as a wide range of solutions for industrial and public utility applications. S-ECTION 22 13 23 - GREASE INTERCEPTORS PART 1 G"iXERAL 1.1 S%CT!001i\CLU0175 A. Grease interceptors. 1.2 RcLATED 5ECTIC?!S A. Section 23 05 00 - Common Work Results for HVAC. 1.3 R77 R2i!CI:S A. CAN/CSA-B481.1: Testing and Rating of Grease Interceptors using Lard. 1.4 SUMMITTALS A. Submit under provisions of Section 01 30 00 - Administrative Requirements. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Minimum 5 years experience manufacturing similar products. B. Installer Qualifications: Minimum 2 years experience installing similar products. 1.6 P-12-INSTALLATiON Pi'-i':T: 'GS A. Convene minimum two weeks prior to starting Work of this section. 1.7 C'�:LIV-,nY, STORAG2, f1ZD',gAigC!-I:�!G A. Deliver and store products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation. B. Handling: Handle materials to avoid damage. 1.8 ?:301 ':C a COi:Ji1":t✓�:; A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits. 1.9 SrF0'_.4f-,' G A. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress. 1.10 ' 'ARRA:'7 Y A. Endura Grease and Solids Management as manufactured by Canplas Industries LLC shall be supported by a 10 year manufacturer's extended warranty. ?A-i': 2 1'!100 is *ZTS 2.1 A. Acceptable Manufacturer: Canplas Industries Ltd.; 500 Veterans Dr. P.O. Box 1800, Barrie, ON, Canada L4M 4V3. ASD. Toll Free Tel: (800) 461-1771. Tel: (705) 726-3361. Fax: (705) 726-2186. Email: canplas@canplas.com Web: http://www.canplas.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 GREASZ 'fANAG- iZNT A. Grease and solids management shall be from a single source of Endura Grease Management products manufactured by Canplas Industries Ltd. 2.3 GREASE INTc:ICEPTORS A. Product: Endura Lo-Pro as manufactured by Canplas Industries Ltd. 1. Model No. 3925A02LO.The interceptor shall be serviced with a minimum of 6 inches (152 mm) of overhead clearance. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally air tight seal. The cover shall also utilize a quick access latching system to functionally retain and secure the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. Flow: 25 US Gallons per Minute (1.6 liter per second). b. Capacity: 50 Pounds (22.68 kg). c. Average Efficiency % (ASME 112.14.3): 97.1 %. d. Grease Capacity Ibs (Kg) actual: 53.4 (24.22). e. Unit Weight (Empty): 23.9 lb (10.85 kg). f. Liquid Capacity:18.9 gal (71.54 Q. g. Connection size (mechanical): 2 inches (51 mm) 010 mm available on request). -13- 2. Model 3922125: A flow control with a rate of 25 gpm (95 Ipm) will also be installed in accordance to manufacturer's instructions. a. Flow Control: 2 inches (51 mm) h x h. b. Air Intake: 2 inches (51 mm) spg x h. B. Product: Endura Compact GI as manufactured by Canplas Industries Ltd. 1. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally airtight seal.The cover shall also utilize a quick access latching system to functionally retain and secure the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. A flow control device with integrated air intake and tool -less access to the orifice in service shall be provided with the interceptor. 2. Model 3907A02 - ENDURA GI 7GPM/14LB. a. Flow Control: Model 3922107C. b. Flow: 7 US Gallons per Minute (0.44 liter per second). c. Capacity: 14 Pounds (6.35 kg). d. Average Efficiency % (ASME 112.14.3): 95.5%. e. Grease Capacity Ibs (Kg) actual: 31.95 (14A9). f. Unit Weight (Empty): 13.8 lb (6.26 kg). g. Liquid Capacity:12.96 gal (49.06 Q. h. Connection size (mechanical): 2 inches (51 mm) 3. Model 391 OA02 - ENDURA GI 10GPM/20LB. a. Flow Control: Model 3922110C. b. Flow: 10 US Gallons per Minute (0.63 liter per second). c. Capacity: 20 Pounds (9.07 kg). d. Average Efficiency % (ASME 112.14.3): 92.5%. e. Grease Capacity Ibs (Kg) actual: 38.1 (17.28). f. Unit Weight (Empty): 13.8 lb (6.26 kg). g. Liquid Capacity:12.96 gal (49.06 Q. h. Connection size (mechanical): 2 inches (51 mm). 4. Model 3915A02C - ENDURA GI 15GPM/30LB. a. Flow Control: Model 3922115C. b. Flow:15 US Gallons per Minute (0.94 liter per second). c. Capacity: 30 Pounds (13.6 kg). d. Average Efficiency % (ASME 112.14.3): 92%. e. Grease Capacity Ibs (Kg) actual: 40.97 (18.58). f. Unit Weight (Empty): 13.8 lb (6.26 kg). g. Liquid Capacity:12.96 gal (49.06 Q. h. Connection size (mechanical): 2 inches (51 mm). C. Product: Grease Interceptor 20-25 GPM as manufactured by Canplas Industries Ltd. 1. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally air tight seal. The cover shall also utilize a quick access latching system to functionally secure and retain the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. A flow control device with integrated air intake and tool - less access to the orifice in service shall be provided with the interceptor. 2. Model 3920A02 - Endura GI 20GPM/40LB. a. Flow Control: 3911120C. b. Flow: 20 US Gallons per Minute (1.26 liter per second). c. Capacity:40 Pounds (18.1 kg). d. Average Efficiency % (ASME 11 2.14.3):95A%. e. Grease Capacity Ibs (Kg) actual: 76.4 (34.65). f. Unit Weight (Empty): 23 lb (10.4 kg). g. Liquid Capacity: 21.6 gal (81.8 Q. h. Connection size (mechanical): 2 inches (51 mm). 3. Model 3925A02 - Endura GI 25GPM/50LB. a. Flow Control: 3922125C. b. Flow: 25 US Gallons per Minute (1.6 liter per second). c. Capacity: 50 Pounds (22.7 kg). d. Average Efficiency % (ASME 112.14.3): 92.5%. e. Grease Capacity Ibs (Kg) actual: 74 (33.6). f. Unit Weight (Empty): 23 lb (I OA kg). g. Liquid Capacity: 21.6 gal (81.8 Q. h. Connection size (mechanical): 2 inches (51 mm). 4. Model 3925A03 - Endura GI 25GPM/50LB. a. Flow Control: 3933125. b. Flow: 25 US Gallons per Minute (1.6 liter per second). c. Capacity: 50 Pounds (22.7 kg). d. Average Efficiency % (ASME 112.14.3): 92.5%. e. Grease Capacity Ibs (Kg) actual: 74 (33.6). f. Unit Weight (Empty): 23 lb (10.4 kg). g. Liquid Capacity: 21.6 gal (81.8 Q. h. Connection size (mechanical): 3 inches (76 mm). D. Product: Grease Interceptor 35-50GPM as manufactured by Canplas Industries Ltd. 1. The unit.shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally air tight seal. The cover shall also utilize a quick access latching system to functionally secure and retain the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. A flow control device with integrated air intake and tool - less access to the orifice in service shall be provided with the interceptor. -14- 2. 3. 4. I•1 Model 393SA03 - Endura GI 3SGPM/70LB. a. Flow Control: 3933135. b. Flow: 35 US Gallons per Minute (2.2 liter per second). c. Capacity: 70 Pounds (31.8 kg). d. Average Efficiency % (ASME 112.14.3): 98.6%. e. Grease Capacity Ibs (Kg) actual:138.5 (62.8). f. Unit Weight (Empty): 45 lb (20.4 kg). g. Liquid Capacity: 39A gal 049.1 Q. h. Connection size (mechanical):3 inches (76 mm) (110 mm available on request). Model 393SA04 - Endura GI 3SGPM/70LB. a. Flow Control: 3934135. b. Flow: 35 US Gallons per Minute (2.2 liter per second). c. Capacity: 70 Pounds (31.8 kg). d. Average Efficiency % (ASME 112.14.3): 98.6%. e. Grease Capacity Ibs (Kg) actual:138.5 (62.8). f. Unit Weight (Empty):45 lb (20.4 kg). g. Liquid Capacity: 39.4 gal (149.1 Q. h. Connection size (mechanical): 4 inches (102 mm). Model 39SOA03 - Endura GI SOGPM/1001.6. a. Flow Control: 3933150. b. Flow: 50 US Gallons per Minute (3.2 liter per second). c. Capacity:100 Pounds (45.4 kg). d. Average Efficiency % (ASME 112.14.3): 93.9%. e. Grease Capacity lbs (Kg) actual:122 (55.3). f. Unit Weight (Empty): 60 lb (27.2 kg). g. Liquid Capacity: 52 gal (197 Q. h. Connection size (mechanical): 3 inches (76 mm) (110 mm available on request). Model 39SOA04 - Endura GI SOGPM/1001.6. a. Flow Control: 3934150. b. Flow: 50 US Gallons per Minute (3.2 liter per second). c. Capacity:100 Pounds (45A kg). d. Average Efficiency %(ASME 112.14.3): 93.9%. e. Grease Capacity Ibs (Kg) actual:122 (55.3). f. Unit Weight (Empty): 60 lb (27.2 kg). g. Liquid Capacity: 52 gal (197 Q. h. Connection size (mechanical): 4 inches (102 mm). 2.4 A. 2. Product: Solids Interceptor as manufactured by Canplas Industries Ltd. Parts in direct contact with flow shall be constructed of engineered thermoplastic capable of withstanding operational temperatures of 220 degree F (104 degree Q. Baffles shall be perforated with slots as opposed circular perforations for enhanced straining of elongated debris e.g. mop strings, spaghetti etc. The solids interceptor shall be removable for cleaning and in operation have a minimum flow rate greater than 50 GPM (3.2 liter per second) when loaded to 50% of its solids -holding capacity. Any baffles/straining method used shall also be removable for maintenance and operation shall use a dual means of filtration on solid material within the flow. When installed in a stand-alone configuration the tank will meet the same specification as above and have both a lid which is airtight and capable of supporting 440 lb (220 kg). Type: Stand Alone Model 3911 A02: Solids Interceptor. Complete with Solids Basket Accessory (SBA): 2 inches (51 mm) inlet. 3. Type: Integral to Interceptor Model 3911 A-1: Solids Basket Accessory (SBA). 3.1 ,..°. A. Do not begin installation until substrates have been properly prepared. B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 rt s S� A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 3.3 �...:`. 1 .. ~.N A. Install in accordance with manufacturer's instructions. B. Do not pressurize any interceptor as there is a serious risk of injury and death. The interceptor as an appurtenance shall be isolated for the purposes of leak testing the upstream and downstream drainage system when commissioning and verifying the system operation. C. Interceptor tank will be installed to the associated drainage system using mechanical joint couplings approved by the Authority Having Jurisdiction (AHJ). Supplied by others. D. When installing in -floor tanks will be filled to static water level with water to prevent movement and resist pressure of backfilling process. E. Cover will be secured in place during backfilling process to maintain structural rigidity and form and to prevent ingress of foreign bodies into both the interceptor and drainage system. 3.4 A. Provide inspection certificates of Authority Having Jurisdiction (AHJ). 3.5�:.. A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. -1s- qlk U Grease Interceptor n. Am, AW*..M' %Mir-sc Its/ Canplas Industries Ltd. P.O. Box 1800, 500 Veterans Dr. Barrie, ON, Canada L4M 4V3 Tel: (705) 726-3361 www.arcat.com www.csc-dcc.ca www.csinet.org Toll Free: 1-800-461-5300 Fax: (705) 726-2186 Toll Free Fax: 1-888-432-2201 j Canplas LILC 11402 East 53rd Ave. Suite 200, Denver, CO, USA 80239 Tel: (303) 373-1918 Toll Free: 1-888-461-5307 Fax: (303) 373-1923 Toll Free Fax: 1-888-461-5309 an 0AIlaXIS Company G601672-M14 Printed In Canada Grease Interceptor i P; t REVIEWED FOR CODE COMPLIANCE APPROVED AUG 14 2015 City of Tukwila: BUILDING DIVISION RECEIVE `AUG 112015 I TUKWIIri Molding a better future PUBLIC WORKS The Canplas manufacturing location in Barrie, RECEIVED Ontario, Canada is ISO9001 and 14001 registered CITY OF TUKWILA facility. Our quality management system has AUG 10 2015 been registered for the design, manufacture and distribution of high quality injection molded PERMIT CENTER CORRECTION products used in plumbing, industrial, ventilation LTR I and central vacuum applications. P& , saw 1DOfI2 ARGq Canplas Industries Ltd. pesc P.O. Box Veterans Dr. VCSI Canplas East 11402 East 5 Ave. N, Ca ad Barrie, ON, Canada L4M 4V3 Tel: (705) 726-3361 env3rd Suite 200, Denver, CO, USA 80239 Tel: (303) 373-1918 www.arcat.com Toll Free: 1-800-461-5300 www.csc-dcc.ca www.csinet.org Fax: (705) 726-2186 Toll Free:1-888-461-5307 Fax: (303) 373-1923 Toll Free Fax: 1-888-432-2201 Toll Free Fax: 1-888-461-5309 www.endurainterceptor.com GD-01677-03-14 Printed In Unada an OAHQXis c=pmy umaii - t-omment Letier rage i of ,+ trfi, ,$)t t,�li. L Comment Letter 2 messages Rachelle Ripley <Rachelle.Ripley@tukwilawa.gov> To: "malikd@gmail.com" <malikd@gmail.com> July 30, 2015 DAVID MALIK 26220 116TH AVE SE KENT, WA 98030 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG 15-0082 CHEVRON - 14415 TUKWILA INTERNATIONAL BL Dear DAVID MALIK, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: devendra malik <malikd@gmail.com> Thu, Jul 30, 2015 at 3:31 PM https://mail.google.com/mail/u/0/?ui=2&ik=164bl b653b&viev--pt&search=inbox&th=14ee... 8/7/2015 The Grease Interceptor Industry has developed significantly in the past decade with not only more advanced and improved products but also development of performance standards and harmonization of common terms and references. Traditionally the term "Grease Trap" was commonly applied and is still used in the industry today. This term is progressively disappearing from nomenclature and technical references based on an industry wide recognition that the term"trap"would suggest the presence ofa water seal, Integrally located within the interceptor. This practice substantially ceased many years ago, modem interceptors being designed to be installed in conjunction with external water seal traps as a standard part of the system. In addition to this clarification, with publication of the 2006 UPC plumbing code three generic types of Grease Interceptor were introduced and have since becomethe industry standard for designating the type of interceptor being considered. Generkaliy the application of a Grease Interceptor regardless of type Is defines as follows: Grease Interceptor. 'A plumbing appurtenance or appliance that is installed in a sanitary drainage system to intercept nonpetroleum fats, oil, and grease (FOG) from a wastewater discharge. Specific characteristics then define the three types of Interceptor: Hydromechanical Grease Interceptor (HGI) An HGI is sized by flow rate (GPM) and qualified separation/retention efficiency, validated against National performance Standards. An HGI Incorporates a defined means of flow control, acts to entrain air to Influent, includes interior baffling, or barriers in combination or separately, working to promote hydromechanical separation. HGI's are generally installed inside the facility they serve." Gravity Grease interceptor (GGi) A GGl is characterized by volume, minimum 30 minute retention time, baffle(s), not less than two compartments, a total volume of not less than 300 gallons (1135 Q, and gravity separation. If not recognized by an official body, a GGI will be designed by a registered professional engineer. GGI's are generally installed outside the building they serve and buried below grade" Grease removal Device (GRD) A GRID is a hydromechanical grease interceptorthat mechanically removes non -petroleum fats, oils and grease (FOG) from the separation chamber, the control of which is either automatic or manually initiated and involves maintaining liquefied state of intercepted FOG by heating. GRD's are installed inside the facility they serve.." wpm I r i National Performance - PDI G101 PDI G101 None - POI G101 Standards -CSA B481 CSA B481 -CSA B481 -ASMEAl12.14.3 - ASME Al 12.14.3 -ASMEA111.14.4 Plumbing Code Approvals/ -UK -UPC UPC (500 USG+) -UPC Listing - IPC - IPC IPC (300 USG+) - IPC - NPCC - NPCC - NPCC - NSPC - NSPC - NSPC Specific AHJ Approval Typically Not Typically Not Yes Yes Material Plastic (PP- Polypropylene) - Cast Iron GRP/Fiberglass Stainless Steel - Epoxy Coated Steel - Concrete - Plastic (PE) - Steel Efficiency 93%-99% -Based on ASME Min 90% (based on Performance No Assessment Possible Min 90% (based on Ai12.14.3 -Tested to breakdown Standards) Performance Standards) Average Lifespan Min 20 years -Typically life of - Cast Iron (10-15 yrs) GRP/Fiberglass (20Yrs+) -Tank (IOYrs+) system - Epoxy Coated Steel (3-5yrs) - Concrete (8-1 Oyrs) - Mechanical (1-3yrs) - Plastic (PE) (20yrs +) Steel (1-12yrs) Managed Flow Yes - with Accessible Flow control Yes (Required for PDI compliance) No Yes Cost Ratio Index - Product 1 .9 -1.5 8-10 6-8 Annual Operation Cost Ratio 1 t 8-10 0.5-1 (Assumes third party service) Footprint Ratio 1 1 Min 10 1 Sizing Method Flow Rate Flow Rate Capacity (US Gallons) Flow Rate Typical Installation Time -On-Floor-2.3hrs -On-Floor -2-3hn 12-15hrs 2-4hrs -In floor -4-6hrs -In Roor-4-8hrs Nature of Installation - Licensed Plumber Licensed Plumber Licensed Plumber/ Groundworker - Licensed Installer - Common tools/practices - Common tools/practices - Earthmoving/Excavation Common tools/practices Installer Profile - LicensedPlumber - LicensedPlumber - LicensedPlumber(HookUp) - LicensedPlumber Ground worker (Install) - Licensed Electrician Product Availability - Stock Item - National/Regional/ - National/Regional/ Local Local/Regional Manufacturer Direct Manufacturer Direct - Local Local Plumbing Wholesale Plumbing Wholesale SpecialOrder-Regional/Local Representation -Restaurant Equipment - Restaurant Equipment Plumbing Wholesale Distributors Distributor -3- Grease Interceptor Series fa Canplas is one of North America's leading producers of plastic products for the building and construction Industries and part of the Aliaxis Group of Companies. Specializing in injection moulded products, Canplas has five decades of expertise and experience in the manufacturing and distribution of plastic plumbing products, processing multiple materials and producing millions of fittings and products on an annual basis. Endura grease interceptors have demonstrated effective, efficient and consistent performance with over a decade offield installation and operation. Endura is a multi -patented product builtto withstand thetoughest environments and provides the flexibility of in -floor, on -floor and semi -recessed application. Canplas has been instrumental in changing the traditional practices regarding the installation of grease management solutions, plastic alternatives to metal interceptors being now substantially accepted Nationwide as the new standard for grease management in commercial foodservice applications. Endura 7GPM -10GPM -15GPM Models !. 3907A02 - 7GPM (0.44 LPS) 2" (51 mm) connection 391 OA02 -10GPM (0.63 LPS) 2" (51 mm) connection 3915A02C - 15GPM (0.94 LPS) 2" (51 mm) connection Compact models use a development of the patented Canplas baffle system to enhance separation performance at low flow rates. EZ-Clean tank design — Aids exterior cleaning. Endura Lo-PRO Grease Interceptor 25GPM Model 3925A02LO 25GPM (1.6 LPS) 2" (51 mm) connection Endura° Lo-PRO for tight on -floor applications where space Is at a premium. Same dimensional footprint as 359pm and 50gpm Endura* models. Overall height 11 Inches, still meeting requirements of ASME112.14.3. Internal components can be removed in less than 6"of additional clearance. Endura 20GPM - 25GPM Models 3920A02 20GPM (1.26 LPS) 2" (51 mm) connection 3925A02 25 GPM (1.6 LPS) 2" (51 mm) connection 3925A03 25 GPM (1.6 LPS) 3"(76mm) connection Our original tank, 20-25gpm units are perhaps the most commonly installed product. Both 2" and 3"connections suit on -floor and in -floor application respectively. Endura 35GPM Models 3935A03 35GPM (2.2 LPS) 3"(76mm) connection 3935A04 35GPM (2.2 LPS) 4"(110 mm) connection Structured foam molding technology provides rigidity and durability while reducing unit weight. Diffuser baffle aids separation at increased flow rates. Endura 50GPM Models 3950A03 50 GPM (3.2 LPS) 3" (76 mm) connection 3950A04 50 GPM (3.2 LPS) 4"(110 mm) connection A tall version of our 35gpm model the 50gpm interceptor uses common parts incorporating all the best features of the Endura product design in a comparatively light weight solution to that of Its metal competitors. Canplas Earth friendly solutions for Grease Management Canplas is committed to the continuous improvement of our environmental performance and to meeting or exceeding the requirements of all applicable environmental laws and regulations. r Recycling our manufacturing . process waste and office waste Economizing in our use of water i and energy to maximize l~ne�rt'�"p� uY'i"i C24?n�� Responsible Manufacturing processes that helps protect the environment +" Continual Product Design refinement to maximize efficiency r * ' while minimizing waste Durability • Fewer installations and replacements result in lower lifetime costs & less landfill waste. • Injection molded in engineered thermoplastics, Endura Grease Interceptors will not corrode, chip, or peel, even under the most severe Applications. • Durability provides consistent operation — no compromise of effectiveness due to deterioration of key parts Green by Design Light -weight grease interceptor units enable smaller carbon footprint and low -emissions transport • Injection molded thermoplastic requires less energy to produce than metal grease interceptors - Endura Interceptors are manufactured a minimum of 5% recycled material. -2. Page 1 o1 i Pilot #:065942173 Reference#:129960 Current Status: RECOVERED AT DESTINATION To receive POD information. Click Here. Date: 08/03/2015 Time: 12:49 (ET) Print Tracking Info **Est. Del. Date: 08/07/2015 17:00 ** Estimated delivery date/time may not be accurate due to services required, residential delivery, or special conditions. Pilot is not responsible for delays due to weather or natural disasters. http: //www.pilotdelivers. com/tracking/ShipmentDetail. aspx?ShipmentID= l 3 3 63 769& Custo... 8/7/2015 " 1,10 Grease Interceptor Model Chart acts Compact tank/ small footprint 7 GPM 3907AO2 - 2" Minimumof5% 10 GPM 391OA02 - 2' Injection molded in proven 15 GPM 3915AO2C - 2- engineered thermoplastics for strength and durability OUTLET INLET EZ-Open cover latches Odor lock cover gasket Ole EZ-(lean exterior tank profile with a Endura Compact Grease Interceptor non -ribbed section at the lower two inches of the tank Connected using 7 GPM 3907AO2 mechanicaljoint couplings 10 GPM 391OA02 lOYear Limited Manufacturers allowing for use ofvarlous 15 GPM 3915AO2C Warranty piping materials. LEVEL, NON ABSORBENT MATERIAL FOR EVEN SUPPORT OF TANK Injection molded in proven engineered thermoplastics for 20 GPM 3920A02 - 2" 25 GPM 3925AO2 - 2' Minimum of5% strength and durability 25 GPM 3925AO3 - 3' EZ-Open cover latches Odor lock cover gasket OUTLET r INLET Load rated cover supports up to 440 Ole pounds of pedestrian and light duty Enclura Grease Interceptor traffic Connected using 20 GPM 3920A02 25gpm with 2"or 3'connections mechanicaljoint couplings 25 GPM 3925AO2 25 GPM 392SA03 10 Year Limited Manufacturers 'llowing for use orivarious Piping materials. LEVEL NON -ABSORBENT Warranty MATERIAL FOR EVEN SUPPORT OF TANK 11 " in height ideal for under sink installation Requires only 6'of clearance for - 25 GPM 3925AO2LO - 2" Minimum of5% maintenance Injection molded in proven engineered thermoplastics for strength and ovw IN - durability EZ-Open cover latches Connected using Odor lock cover gasket mechanical joint couplings Endura Low Profile Grease Interceptor EZ-(Iean tank exterior allowing for use ofvadous piping materials. LEVEL, NON -ABSORBENT 25 GPM 3925A021.0 10 Year Limited Manufacturers MATERIAL FOR EVEN SUPPORT OF TANK Warranty Injection molded in proven engineered 35 GPM 3935A03 - 3' Minimum ofS% thermoplastics for strength and 35 GPM 3935AO4 - 4" durability EZ-Open cover latches Odor lock cover gasket Load rated cover supports up t( 440 ) OUTLET INLET g pounds of pedestrian and light duty I traffic Connected using 10 Year Limited Manufacturers mechanical joint couplings allowing for use of various Endura Grease Interceptor Warranty piping materials. _­l=LEVEI 35 GPM 3935AO3 35 GPM 3935AO4 Supplied with 2 piece flow control NON -ABSORBENT MATERIAL FOR EVEN SUPPORT OF TANK Injection molded in proven engineered 50 GPM 395OA03 - 3" Minimum of5% thermoplastics for strength and 50GPM 39SOA04 - 4" durability MERRIER EZ-Open cover latches Odor lock cover gasket Load rated cover supports up to 440 — &1 T1 I I ' l OUTLET INLET pounds ofpedestrian and light duty traffic 10 Year Limited Manufacturers Connected using mechanical joint couplings allowing for use of various Warranty piping materials. Endura Grease Interceptor 50 GPM 3950A03 Supplied with 2 piece flow control 50 GPM 395OA04 LEVEL, NON -ABSORBENT MATERIAL FOR EVEN SUPPORT OF TANK -4- CONCRETE FLOOR NYC 3-Part Master Commonwealth Format cq° of Massachusetts Specifications, G-101 CAD drawimgs & BIM drawings AContinuous available at N/A N/A 6 Si:a discharge atp.) �e1.1l 104'C(220'Fl /Kq.com `4E At 12.14.3 MU I"606f Installation Guide available at Check local codes for acceptance of in -floor installation Finish to floor level accommodating requisite materials, � d endurainterceptor.com E.G.TIe, mortar, etc. " Excluding 7 GPM CONCRETE FLOOR MODULAR EXTENSION RISER AVAILABLE �1 NYC Commonwealth 3-Part Master Format 4z? r. • e` f; c-101 of Massachusetts Specifications, CAD drawimgs & BIM drawings 11 8481.1 s. Continuous discharge atallows available at (]�'/��' Sleeve access3"mooarflowdel only, % e 104-C(220'F) /� tqr V.com 6" Modular riser control devictoln-floorflow Custom Custom length of SDR 35 or SDR A�k Alz143 M Installation • Finish to floor level accommodating -Measurementmarkings Stadcableupto3sets(18"Total) 28 sewer pipe to be used for access sleeve °" �® �d Guide available at endurainterce ptor.com requisite -3920AX6 -3"392203W,6'SDR35/28 materials, E.G. Tile, mortar, etc sewer pipe diameter NYC 3-Part Master Commonwealth Format G-101 of Massachusetts Specifications, On Floor CAD drawimgs Installation Only B481.1 Continuous & BIM drawings available at N/A N/A E gs yg< ^w•� discharge at 104-C (220'F) p�/�'� / V C V .cam INAAate.. Al 12.14.3 Installation Guide available at enduainterceptor.com CONCRETE MODULAR r EXTENSION FLOOR / RISER AVAILABLE '�� I O NYC Commonwealth of Massachusetts 3-Part Master Format Specifications, CAD drawimgs g s & BIM drawings �7 Continuous availableat s. Sleevekitailowsaccessto In -floor flow control device Bae1.1 o� yP discharge at 104-C(220'F) /� p / �]C U.Com Custom length of SDR35orSDR 6"Modularriser 28 sewer pipe to be used for A112.14.3 Installation Measurement markings -Stadcableupto3sets(18"Total) access sleeve 3"392203W,6"SDR35R8 °p� S-!:w Guide available at enduainterceptoccom Finish tofloorlevelaccommodatingrequisite -3935AX6 sewer pipe diameter materials, E.G. Tile, mortar, etc 4"392204W, 8"SDR 35/28 e sewer pipe diameter MODULAR CONCRETE EXTENSION FLOOR RISER AVAILABLE I-=— !�"'`7 ��, ">r'-+++- c-101 ° NYC Commonwealth of Massachusetts 3-Part Master Format Specifications, r *' .. SP° Continuous CAD drawimgs & BIM drawings available at o Sleeve kitallowsaccessto B481.1( '`f "IE g, Yr- ��-yam discharge at 104'((220'F) /� p�/�� / RC V .com f I f % 6"Modularriser In -floor A112A4.3 Installation 1. -Measurement markings Stadcableupto3sets(18"Total) 393SAX6 Custom length of5DR35or5DR 28sewerpipetobeusedfor access sleeve °po o Guide available at enduainterceptocmm - - 3"392203W, 6'SDR 35/28 ;0 Finish to floor level accommodating requisite sewer pipe diameter - 4"392204W, 8"SDR 35/28 materials, E.G. Tile, mortar, etc sewer pipe diameter Endura® 14.5" LATCHESftlYPROPYLEENE REINFORCED7GPM -10GPM -15GPM °° POLYPROPYLENE no 00 00°0008 0� •:rti� COVERm' `d' p•:ModelsINLET R 3907AO2 - 7GPM (0.44 LPS) 2" (51 mm) connection 391 OA02 - 1 OGPM (0.63 LPS) 2" (51 mm) connection 3915AO2C - 15GPM (0.94 LPS) OUT 2" (51 mm) connection TOP VIEW i--14.5' 1 INLET Notes: 12 8 ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2"INLET/ 1z° ONE-PIECE TANK ISO VIEW i 17.5" 1' 1 3.5" OUTLET MODELS FRONTVIEW SIDE VIEW En ura® 23.6" LATCHES REINFORCED jjjfl�POLYPROPYLENE °°®°°°°°°°°®°°�° COVER 0 M - 25GPM Models �oaoa000 aooa°aa0000000 0° o� 3920A02 20GPM (1.26 LPS) 2" (51 mm) connection 3925AO2 25 GPM (1.6 LPS) 2" (51 mm) connection 3925AO3 25 GPM (1.6 LPS) 3"(76mm) connection Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2" or 3" INLET/OUTLET MODELS Endura Lo-PRO Grease Interceptor 25GPM Model 3925AO2LO 25GPM (1.6 LPS) 2" (51 mm) connection Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2- INLET/OUTLET MODEL 1 TOP VIEW I-23.6 -{ oU I I D Dimension: 3920A02:12.8" 3925A02: 12.8" 3925A03: 12.2" FRONT VIEW 31" 23.5" INLI INLET ECE i„rvn 150 VIEW --17s =I1 C 16 3" C Dimension: 3920A02: 3.5" 3925A02: 3.5" L 3925A03: 4.1" 1s"­__� SIDE VIEW LATCHES REINFORCED POLYPROPYLENE COVER INLET ONE-PIECE TANK TOP VIEW ISO VIEW OUTLET 31-INLET23.5"--{� 4" E727.8757" 11" i 7 20.5" FRONT VIEW SIDE VIEW -6- 3935A03 35GPM (2.2 LPS) 3" (76mm) connection 3935A04 35GPM (2.2 LPS) 4" (110 mm) connection Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -3" or 4" INLET/OUTLET MODELS Endura° 50GPM Models 3950A03 50 GPM (3.2 LPS) 3" (76 mm) connection 3950A04 50 GPM (3.2 LPS) 4" (110 mm) connection Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -3"or 4" INLET/OUTLET MODELS 2. TOP VIEW INLET 31 OUTLET I INLET 12.5" 1 �I f 29--I FRONT VIEW TOP VIEW 31 OU 1 f 29°---.a FRONT VIEW LA INLET INLET 2 ISO VIEW i-23.5'=—I SIDE VIEW E-PIECE JK REINFORCED °^'VPROPVLENE ER ISO VIEW 23.5'=� SIDE VIEW VE-PIECE \NK -7- Sizing For Endura models Canplas recommends sizing by flow rate. The use of a flow control with a Hydromechanical Grease Interceptor is considered mandatory. Without a properly sized flow control, the discharge rate through into the interceptor may exceed the design rating of the unit, causing lower efficiencies and increase the risk of grease, passing into the downstream system. Be careful not to confuse liquid capacity and flow rate. Liquid capacity is stated in gallons (or liters) while flow rate is referenced in gallons per minute (gpm) or Usec. If sizing based on a 1 minute drain time indicates that a higher flow rate interceptor is required, there are two options. 1. Use a larger interceptor to accommodate full accommodate the flow of the 1min drain down 2. Use a 2 min drain time in your calculation •. Sink Size SizingGuide LPS US/GPM 2" 84 22 3" 142 37.5 4" 170 45 FloorDrains & Floor Take the volume of water produced by the number of hose bibs (ie 1.5-2.0 gpm per 3/4" faucet) Note: If using a 2 minute drain time this will cause the interceptor to be 50% of the original number calculated. Although a smaller unit will be less expensive, the lesser grease capacity will dictate an increased frequency of cleaning. physical 9 P Y q Y Sizing Calculator } Visit our website for our easy to use online GI Sizing Calculator. www.EnduraGiCalculator.com Table A - Procedure for Sizing Grease Interceptors STEP FORMULA EXAMPLE 1 Determine cubic content of fixture by multiplying length x A sink 24" long by 20"wide by 12" deep. width x depth Cubic content: 24 x 20 x 12 = 5,760 cubic inches (61.0x50.8x30.48cm3) 2 Determine capacity in gallons. 1 = 231 cubic inches Contents in gallons: 5,760 gallon / 231 = 24.9 gallons (94,451.42 / 1,000 = 94.45 litres) 3 Determine actual drainage load. The fixture is normally filled to approximately 75% of capacity Actual drainage load: 75 x 24.9 =18.7 gallons with water as the items being washed displace about 25% of (0.75 x 94.45 = 70.84 litres) the total fixture content. Actual drainage load = 75% of fixture capacity 4 Determine flow rate and drainage period. Calculate flow rate for one minute drainage period: In general, good practice dictates a one minute drainage pe- 18.7 / 1 = 18.7 g.p.m. flow rate riod; however, where conditions permit, a two minute drainage (70.84 / 1 min. = 70.84 I.p.m.) period is acceptable. Drainage period is defined as the actual Calculate flow rate for two minute drainage period: time required to completely drain the fixture. 18.7 / 2 = 9.4 g.p.m. flow rate Flow rate = Actual Drainage Load (70.84 / 2 min. = 35.42 I.p.m.) Drainage Period 5 Select Interceptor. For a one minute drainage period: From Table B select the interceptor with a flow rating at least equal to the calculated flow rate. When the calculated flow rate 18.7 g.p.m. (70.84 I.p.m.) flow rate = 20 g.p.m. G.I. For a two minute drainage period: falls between two sizes, select the larger of the two 9.4 g.p.m. (35.42 I.p.m.) flow rate = 10 g.p.m. G.I. interceptors. Table• • PDI Size Symbol • 4 • Grease 7 Interceptors 10 15 20 25 35 50 Flow Rate US Gallons per Minute (GPM) 4 7 10 15 20 25 35 50 Flow Rate Liters per Second (LPS) .25 .44 .63 .95 1.26 1.58 2.20 3.16 Grease Capacity Pounds (Lbs) 8 14 20 30 40 50 70 100 Grease Capacity Kilograms (Kgs) 3.63 16.35 19.07 113.61 118.14 122.68 131.75 45.36 -8- - PDI Rating (GPM) 7 1 10 1 15 1 20 1 25 LO 1 25 1 35 1 50 Capacity - min. (Ibs) 14 1 20 30 40 50 1 50 1 70 1 100 UtresPerSecond -(LPS) 0.44 0.63 0.94 1.26 1.6 1.6 2.2 3.2 Capacity -(Kg) 6.35 9.07 13.6 18.1 22.68 22.7 31.8 45.4 Endura Part Number 3907AO2 391OA02 3915AO2C 392OA02 3925AO2LO 3925AO2 (21 3935AO3 (3") 39SOA03 (3") 3925AO3 (3") 393SA04 (41 395004 (V) Average Effidency%(ASME A112.14.3) 95.5% 92.5% 92.0% 95.4% 97.1% 92.5% 98.6% 93.9% Actual Grease Capacity lbs (Kg) 31.95 (14.49) 33.1(17.28) 34.97 (18.58) 76.4 (34.65) 53.4 (24.22) * 74 (33.6) 138.5 (62.8) " 122 (55.3) Operating Temperature Capabilities 220'F 220'F 2201 220'F 2207 2201 1107 2207 (104'() (104'Q (104-C) (104'C) (104'Q (104.0 (104'C) (104-C) Cover Load Capacity 440lbs 440lbs 440lbs 440lbs 4401bs 440lbs 440lbs 440lbs (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) (200 kgs) Unit Weight Capacity (Empty) 15.8Lbs 15.8Lbs 15.8Lbs 23lbs 23.9lbs 23lbs 451bs 60lbs (7.17kgs) (7.17kgs) (7.17kgs) (10.4 kgs) (10.85 kgs) (10.4 kgs) (20.4 kgs) (27.2 kgs) Liquid Capacity 12.96 gal 12.96 gal 12.96 gal 21.6 gal 18.9 gal 21.6 gal 39.4 gal 52.0 gal (49.06 L) (49.06 L) (49.06 L) (81.8 L) (71.54L) (81.8 L) (149.1 L) (1971) Connection size (nominal) 2' 2" 2" 2" 2" 2(3925AO2) 3"(3935AO3) 3"(395OA03) 3"(392SA03) 4"(3935AO4) 4"(395OA04) Capacity based POI G101 minimum requirements for respective GPM rating at ASME Al12.14.3 Breakdown. Actual Grease Capacity recorded at Breakdown of ASME Al 12.14.3 test. (Q� 1 Piece Compact Flow Control Flow Control & Air Intake Combined Connection Compact Iron Pipe Size (Solvent weld) 2"h x h l3 A -� A 3.94" (100mm) B 3.44" (87.4mm) C Qb 2 Piece Flow Controls (3"Version Illustrated) Flow Control Body Air Intake Tee Connection Iron Pipe Size (Solventweld) 2"hxh 3"hxh 4"hxh e { I i y�� Iffi 3"spgxh 4"spgxh A 3" (76.2mm) 4.23" (107.4mm) 6.13" (155.7mm) 2.67" (67.8mm) 3.19" (81mm) B 3.84" (97.5mm) 5.93" 1 (151mm) 6.84" (173.7mm) k-"->I I -A.] 4.01" (101.9mm) 5.0V (128mm) C 2.27" 2.72" (57.7mm) (69.1mm) n sta I I a t i o n Every Canplas interceptor is supplied with full installation and operation instructions. The Installation, Use & Care manual is available for reference at http-//www.canplaspiumbing.com/Portals/9/ProductDownloads/3935A-17_Endura_GI_Manual.pdf [CdutlOnS Bef� e WARNING! DO NOT PRESSURE TEST. RISK OF SERIOUS INJURY. As a gravity fed plumbing appurtenance, a grease interceptor MUST be isolated from the drainage system in the event that final drain testing or other system pressure testing is required by the AHJ. fma A Venting - Grease Interceptors must have a vented waste, sized in accordance with local code requirements for venting interceptors to retain a CAUTION watersealand prevent siphoning. Most codes dictate that two vents be installed, one upstream and one downstream of the grease interceptor. The upstream vent must not be placed between the air intake and the grease interceptor. A System longer than 8 feet? - If more than 8 feet (2.4 m) of fall exists between appliance outlet and interceptor inlet, a secondary flow control must be installed immediately CAUTION preceding the grease interceptor to maintain flow velocities in the system. See installation drawing. A Installed under a sink - If installed under a sink or similar obstruction ensure there is sufficient clearance to remove the baffles for cleaning and maintenance. Clearance of 21" CAUTION for 50 GPM models, 5" for LoProfile model, 15" for all other models. If this is not practical, semi -recessing the tank may bean option. Floor Drains - Some local jurisdictions require that the 1 interceptor service the floor drains. The floor drain must bypass the flow control to ensure the restriction does CAUTION not flood the drain. Therefore, the flow control should be installed as close to the fixture as possible or directly preceding the floor drain connection. -9- Installation., All Endura Grease Interceptors are manufactured with standard no hub connections to accept locally approved/accepted MJ (Mechanical Joint) couplings. This method allows resilience in the connections to prevent stress and a flexible means of integrating metallic or plastic plumbing systems. Should adaption of pipe connection be required, use appropriate mechanical joint reducers but do not allow decrease pipe diameter across the unit. (i.e. 3 inch inlet, 2 inch outlet.) Due to regional and local code variation, models with threaded connections (FPT) are available by adding suffix'T'to the part number. Both tank and flow control (TFCD) will be supplied with FPT connections in this instance based on the respective nominal pipe size. Likewise Endura Interceptors can be supplied with spigot format flow controls (SFCD) by adding suffix'S'to the part number. Please Note: Solvent cement is not an acceptable jointing method from the piping system to the interceptor. This will result in leakage. � ow Cent of In to la ion The flow control device furnished with the Endura Grease Interceptor is essential to the proper operation of this unit. The flow control limits the unit to its rated capacity allowing enough time for grease separation to take place inside the interceptor. The flow control fitting is molded in PVC and must be solvent welded using PVC or PVC/ABS transition cement as appropriate. It is to be located in the drain line beyond the last connection from the fixture and as close as possible to the underside of the lowest fixture, see page 6-7 for typical installation. When the discharge from two or more sinks or fixtures are combined and served by one interceptor, a single flow control fitting should be used. The flow control device can be recessed into the floor if required and extension sleeves are available to complete a good finish at final floor level. Compact Hub Version " l Version , c Example:3933125 :* Example:3922125C 1pieceformat / 2pieceformat (' 11 -3"&4"models L. ! (2"available) • Flow direction —r - Spigot Version Example:3933125S t % — 2piece format f -3"&4"models ! (2"available) Threaded Version Example:393312ST �— 2pieceformat The installation of a ball valve upstream of the flow control is recommended. A ball valve provides a means of drain line isolation for maintenance. Some local plumbing codes require that grease interceptors have an internal flow control to ensure drain lines do not bypass the grease interceptor. However, if the flow control device is located immediately upstream of an interceptor, this is often considered as forming part of the interceptor. Therefore, officials having jurisdiction may accept such design as meeting the intent of the requirement. If local codes dictate the flow control must be installed directly preceding the grease interceptor inlet, and the fixtures being served are in excess of 8 ft (2.4 m) from the interceptor, we recommend a second flow control being installed as close to the last fixture as possible. Please contact your local representative if you require further clarification. ) AIR INTAKE AIR INTAKE �N • Preferred Installation s=. •t• r •F, y • bpi3onal'k5 Floor Indire Con e • •dons AM ap AIR INTAKE right Enclosures Some local jurisdictions require warewashing installations to be made on an indirect basis incorporating an air gap. An air gap prevents back up of contaminated water into the sinks/appliances in the event of a system back flow. The flow control device must be incorporated before the indirect connection to prevent overflow occurring during high/maximum waste water Fbw control oeAce discharge. If an air gap is located within 6"of flow control device, installation of the air intake tee is optimal. (*Verify with Authority Having Jurisdiction) Gap/ Air Break -10- Installation A\ Do Not Exceed 25 It (7.6 m) Do Not Exceed 25 ft (7.6 m) O• Flow Control Device © • Vented Waste © • Grease Interceptor O • Air Intake © • Sink OA Minimum Clearance • 15"/21" Lo-PRE Gr -a n erceptor QCAUTION: CLEARANCE REQUIRED 15" clearance (21"for 50 GPM model) to remove the baffles for CAUTION cleaning and maintenance. O• Flow Control Device © • Semi Recessed Option i© • Grease Interceptor O' Sink © • Vented Waste O . Q Minimum Clearance 15"/ 21 " OAir Intake QWhen backfilling in -floor, the interceptor must have both the cover fitted and be filled with water to the inlet/outlet level. This will ensure the tank itself will not move during backfilling, CAUTION pouring and/or floor finishing. When backfilling in particular, care should be taken to do so evenly around the unit and with light manual pressure only. QEnsure that the interceptor is clearly identified to flooring contractors to prevent it from being covered with flooring CAUTION material. Taping cardboard to the cover is generally effective. QCAUTION: CLEARANCE REQUIRED 15"clearance (21 "for 50 GPM model) above the grease interceptor CAUTION is required to remove the baffles for cleaning and maintenance. 6" Modular risers available where deeper installation is necessary to accomodate existing drainage. Stackable up to 3 sets (18"Total) 3920AX6 (20/25gpm) and 3935AX6 (35/50gpm) The Endura Lo-PRO is installed on floor. Ensure you design locate the grease interceptor so as to allow for maintenance. Placement should allow the cover to be easily removed for cleaning. A minimum clearance of only 6 inches is required above the top of the Grease Interceptor to allow removal of the internal baffles for a complete cleanout. QCAUTION: CLEARANCE REQUIRED 6"clearance above the grease interceptor required to CAUTION remove the baffles for cleaning and maintenance. O• Flow Control Device ©• Grease Interceptor © • Vented Waste Q • Air Intake © •QMinimum Clearance 6" O •Sink Cleanout maybe required in some jurisdictions MTV iyp' F. r U tt ! I Multiple Fixture Installation I One interceptor serving multiple fixtures is recommended only when the fixtures are located © ' j close together (max 25ft of developed pipe run). In such installations, each fixture should be individually trapped and back -vented. * If more than 8 feet (2.4 IT), a *8 f� secondary flow control must be installed preceding the grease • interceptor to maintain flow velocities in the system. • Fork Lift, Pump Truck Traffic Area ! ;u�I�-: D. 5 ON dedI allatoon ii Idl+l Do Not Exceed 25 ft (7.6 m) 0 • Flow Control Device © • Grease Interceptor © •Vented Waste Q• Air Intake © • Sink QProvision of a concrete pit with a load rated access cover will be required where pump CAUTION trucks of fork lifts travel. O• Flow Control Device ©• Vented Waste © • Grease Interceptor O • Air Intake © • Hanger (Supplier by installer) O • Sink O• Concrete pit Q • Load Rated Access Cover ADue to the degree of risk and potential liability for the installer, great care must be taken in designing a hanger system. Canplas recommends consulting CAUTION an engineer before installing in this manner. O• Flow Control Device ©• Vented Waste © • Grease Interceptor O • Air Intake © • Hanger (Supplier by Installer) O • Sink A Hanger must accommodate min. 541 Ibs (246kg) plus safety. CAUTION -12- Specifications SPEC NOTE: See www.arcat.com website for Microsoft Word (editable) document. SPEC NOTE: Canplas LLC and Canplas Industries Ltd. are members of the Aliaxis Group of companies, a global leader of plastic solutions for fluid transport in the field of building materials. The Aliaxis Group provides products for both residential and commercial building markets, in new build and renovation segments, as well as a wide range of solutions for industrial and public utility applications. SECTION 2213 23 - GREASE INTERCEPTORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Grease interceptors. 1.2 RELATED SECTIONS A. Section 23 05 00 - Common Work Results for HVAC. 1.3 REFERENCES A. CAN/CSA-B481.1:Testing and Rating of Grease Interceptors using Lard. 1.4 SUBMITTALS A. Submit under provisions of Section 01 30 00 - Administrative Requirements. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Minimum 5 years experience manufacturing similar products. B. Installer Qualifications: Minimum 2 years experience installing similar products. 1.6 PRE -INSTALLATION MEETINGS A. Convene minimum two weeks prior to starting Work of this section. 1.7 DELIVERY, STORAGE, AND HANDLING A. Deliver and store products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation. B. Handling: Handle materials to avoid damage. 1.8 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits. 1.9 SEQUENCING A. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress. 1.10 WARRANTY A. Endura Grease and Solids Management as manufactured by Canplas Industries LLC shall be supported by a 10 year manufacturer's extended warranty. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Canplas Industries Ltd.; 500 Veterans Dr. P.O. Box 1800, Barrie, ON, Canada L4M 4V3. ASD.Toll Free Tel: (800) 461-1771. Tel: (705) 726-3361. Fax: (705) 726-2186. Email: canplas@canplas.com Web: http://www.canplas.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 GREASE MANAGEMENT A. Grease and solids management shall be from a single source of Endura Grease Management products manufactured by Canplas Industries Ltd. 2.3 GREASE INTERCEPTORS A. Product: Endura Lo-Pro as manufactured by Canplas Industries Ltd. 1. Model No.3925A02LO.The interceptor shall be serviced with a minimum of 6 inches (152 mm) of overhead clearance. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally airtight seal.The cover shall also utilize a quick access latching system to functionally retain and secure the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. Flow: 25 US Gallons per Minute (1.6 liter per second). b. Capacity: 50 Pounds (22.68 kg). c. Average Efficiency % (ASME 112.14.3): 97.1%. d. Grease Capacity Ibs (Kg) actual: 53.4 (24.22). e. Unit Weight (Empty): 23.9 lb (10.85 kg). f. Liquid Capacity:18.9 gal (71.54 Q. g. Connection size (mechanical): 2 inches (51 mm) (110 mm available on request). -13- 2. Model 3922125: A flow control with a rate of 25 gpm (95 Ipm) will also be installed in accordance to manufacturer's instructions. a. Flow Control: 2 inches (51 mm) h x h. b. Air Intake: 2 inches (51 mm) spg x h. B. Product: Endura Compact GI as manufactured by Canplas Industries Ltd. 1. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally air tight seal.The cover shall also utilize a quick access latching system to functionally retain and secure the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. A flow control device with integrated air intake and tool -less access to the orifice in service shall be provided with the interceptor. 2. Model 3907A02 - ENDURA GI 7GPM/14LB. a. Flow Control: Model 3922107C. b. Flow: 7 US Gallons per Minute (0.44 liter per second). c. Capacity: 14 Pounds (6.35 kg). d. Average Efficiency % (ASME 112.14.3): 95.5%. e. Grease Capacity Ibs (Kg) actual: 31.95 (14.49). f. Unit Weight (Empty): 13.8 lb (6.26 kg). g. Liquid Capacity:12.96 gal (49.06 Q. h. Connection size (mechanical): 2 inches (51 mm) 3. Model 391 OA02 - ENDURA GI 10GPM/20LB. a. Flow Control: Model 3922110C. b. Flow: 10 US Gallons per Minute (0.63 liter per second). c. Capacity: 20 Pounds (9.07 kg). d. Average Efficiency % (ASME 112.14.3): 92.5%. e. Grease Capacity Ibs (Kg) actual: 38.1 (17.28). f. Unit Weight (Empty): 13.8 lb (6.26 kg). g. Liquid Capacity:12.96 gal (49.06 Q. h. Connection size (mechanical): 2 inches (51 mm). 4. Model 391 SA02C - ENDURA GI 15GPM/30LB. a. Flow Control: Model 3922115C. b. Flow: 15 US Gallons per Minute (0.94 liter per second). c. Capacity: 30 Pounds 03.6 kg). d. Average Efficiency % (ASME 112.14.3): 92%. e. Grease Capacity Ibs (Kg) actual: 40.97 (18.58). f. Unit Weight (Empty): 13.8 lb (6.26 kg). g. Liquid Capacity:12.96 gal (49.06 Q. h. Connection size (mechanical): 2 inches (51 mm). C. Product: Grease Interceptor 20-25 GPM as manufactured by Canplas Industries Ltd. 1. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally air tight seal.The cover shall also utilize a quick access latching system to functionally secure and retain the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access.The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. A flow control device with integrated air intake and tool - less access to the orifice in service shall be provided with the interceptor. 2. Model 3920A02 - Endura GI 20GPM/40LB. a. Flow Control: 3911120C. b. Flow: 20 US Gallons per Minute (1.26 liter per second). c. Capacity:40 Pounds (18.1 kg). d. Average Efficiency % (ASME 112.14.3): 95.4%. e. Grease Capacity Ibs (Kg) actual: 76.4 (34.65). f. Unit Weight (Empty): 23 lb (10.4 kg). g. Liquid Capacity: 21.6 gal (81.8 Q. h. Connection size (mechanical): 2 inches (51 mm). 3. Model 3925A02 - Endura GI 25GPM/50LB. a. Flow Control: 3922125C. b. Flow: 25 US Gallons per Minute (1.6 liter per second). c. Capacity: 50 Pounds (22.7 kg). d. Average Efficiency % (ASME 112.14.3): 92.5%. e. Grease Capacity Ibs (Kg) actual: 74 (33.6). f. Unit Weight (Empty): 23 lb (10.4 kg). g. Liquid Capacity: 21.6 gal (81.8 Q. h. Connection size (mechanical): 2 inches (51 mm). 4. Model 3925A03 - Endura GI 25GPM/50LB. a. Flow Control: 3933125. b. Flow: 25 US Gallons per Minute (1.6 liter per second). c. Capacity: 50 Pounds (22.7 kg). d. Average Efficiency % (ASME 112.14.3): 92.5%. e. Grease Capacity Ibs (Kg) actual: 74 (33.6). f. Unit Weight (Empty): 23 lb (10.4 kg). g. Liquid Capacity: 21.6 gal (81.8 Q. h. Connection size (mechanical): 3 inches (76 mm). D. Product: Grease Interceptor 35-50GPM as manufactured by Canplas Industries Ltd. 1. The unit shall be comprised of engineered thermoplastics to withstand operational temperatures up to 220 degree F (104 degree C) comprising a pedestrian rated cover capable of supporting 440 lb (200 kg)and incorporating an operationally air tight seal. The cover shall also utilize a quick access latching system to functionally secure and retain the cover to the tank, but allow consistent removal and replacement of the cover without operational compromise. Functional elements such as baffles will be made of material that prevents corrosion or deterioration and shall be easily removable for the purposes of maintenance, providing unrestricted upstream and downstream drain access. The grease interceptor shall be certified to the current version of the PDI-G101, ASME Al 12.14.3 or CSA B481.1 and where locally applicable have UPC listing. a. A flow control device with integrated air intake and tool - less access to the orifice in service shall be provided with the interceptor. -14- 2. Model 3935A03 - Endura GI 35GPM/70LB. a. Flow Control: 3933135. b. Flow: 35 US Gallons per Minute (2.2 liter per second). c. Capacity: 70 Pounds (31.8 kg). d. Average Efficiency % (ASME 112.14.3): 98.6%. e. Grease Capacity Ibs (Kg) actual:138.5 (62.8). f. Unit Weight (Empty): 45 lb (20.4 kg). g. Liquid Capacity: 39.4 gal (149.1 Q. h. Connection size (mechanical): 3 inches (76 mm) (110 mm available on request). 3. Model 3935A04- Endura GI 35GPM/70LB. a. Flow Control: 3934135. b. Flow: 35 US Gallons per Minute (2.2 liter per second). c. Capacity: 70 Pounds (31.8 kg). d. Average Efficiency % (ASME 112.14.3): 98.6%. e. Grease Capacity Ibs (Kg) actual:138.5 (62.8). f. Unit Weight (Empty):45 lb (20.4 kg). g. Liquid Capacity: 39.4 gal (149.1 Q. h. Connection size (mechanical): 4 inches (102 mm). 4. Model 3950A03 - Endura GI 50GPM/1001.8. a. Flow Control: 3933150. b. Flow: 50 US Gallons per Minute (3.2 liter per second). c. Capacity: 100 Pounds (45.4 kg). d. Average Efficiency % (ASME 112.14.3): 93.9%. e. Grease Capacity Ibs (Kg) actual:122 (55.3). f. Unit Weight (Empty): 60 lb (27.2 kg). g. Liquid Capacity: 52 gal (197 Q. h. Connection size (mechanical): 3 inches (76 mm) 010 mm available on request). 5. Model 395OA04 - Endura GI 50GPM/100LB. a. Flow Control: 3934150. b. Flow: 50 US Gallons per Minute (3.2 liter per second). c. Capacity:100 Pounds (45.4 kg). d. Average Efficiency % (ASME 112.14.3): 93.9%. e. Grease Capacity Ibs (Kg) actual:122 (55.3). f. Unit Weight (Empty): 60 lb (27.2 kg). g. Liquid Capacity: 52 gal (197 Q. h. Connection size (mechanical):4 inches (102 mm). 2.4 SOLIDS INTERCEPTOR A. Product: Solids Interceptor as manufactured by Canplas Industries Ltd. 1. Parts in direct contact with flow shall be constructed of engineered thermoplastic capable of withstanding operational temperatures of 220 degree F (104 degree C). Baffles shall be perforated with slots as opposed circular perforations for enhanced straining of elongated debris e.g. mop strings, spaghetti etc. The solids interceptor shall be removable for cleaning and in operation have a minimum flow rate greater than 50 GPM (3.2 liter per second) when loaded to 50% of its solids -holding capacity. Any baffles/straining method used shall also be removable for maintenance and operation shall use a dual means of filtration on solid material within the flow. When installed in a stand-alone configuration the tank will meet the same specification as above and have both a lid which is airtight and capable of supporting 440 lb (220 kg). 2. Type: Stand Alone Model 3911 A02: Solids Interceptor. Complete with Solids Basket Accessory (SBA): 2 inches (51 mm) inlet. 3. Type: Integral to Interceptor Model 3911 A-1: Solids Basket Accessory (SBA). PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until substrates have been properly prepared. B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 3.3 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Do not pressurize any interceptor as there is a serious risk of injury and death. The interceptor as an appurtenance shall be isolated for the purposes of leak testing the upstream and downstream drainage system when commissioning and verifying the system operation. C. Interceptor tank will be installed to the associated drainage system using mechanical joint couplings approved by the Authority Having Jurisdiction (AHJ). Supplied by others. D. When installing in -floor tanks will be filled to static water level with water to prevent movement and resist pressure of backfilling process. E. Cover will be secured in place during backfilling process to maintain structural rigidity and form and to prevent ingress of foreign bodies into both the interceptor and drainage system. 3.4 FIELD QUALITY CONTROL A. Provide inspection certificates of Authority Having Jurisdiction (AHJ). 3.5 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION -15- City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 4/ 1 /2016 DAVID MALIK 26220 116TH AVE SE KENT, WA 98030 RE: Permit No. PG15-0082 CHEVRON 14415 TUKWILA INTERNATIONAL BL Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/10/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. zre 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/10/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: PG] 5-0082 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director July 30, 2015 DAVID MALIK 26220 116TH AVE SE KENT, WA 98030 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG15-0082 CHEVRON - 14415 TUKWILA INTERNATIONAL BL Dear DAVID MALIK, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size I Ix17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. Please provide a floor plan and isometrics showing plumbing layout of drain waste/vent and water supply to each fixture, point of connection, floor drain traps provided with trap primers and T P specifications, RPPBP location with specifications and any other new plumbing fixtures and piping not specified. Floor plan plumbing drawings shall be on 11 x 17 sheets to scale where notes and drawings are legible. Reduced sheets shall not be acceptable. 2. Provide manufactures installation and specifications for the grease interceptor. Be clear with drawings if necessary the location is such that it will be convenient for serving. PW - PG DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1. Your Plumbing Permit application lists one (1) backflow, however no backflow is depicted on your plan. What will this backflow protect? Please show location of proposed backflow, specify size/manufacturer/model number on your plan. What is this backflow protecting? 2. Submit backflow cut sheet, circle the devise to be installed. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard .Suite #700 • Tukwila Washington. 98188 * Phone 206-4.3 7- 3670 • Fax 206-4.31-.3665 In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, kw V 11 Rachelle Ripley Permit Technician File No. PG15-0082 630f) Snuthrentar Rnl/levnrd .G/ity #100 • Tukwdn Wn.chinvtnn 9R/RR 6 Phnna 206-437-3670 • Fnr 906-d31-g665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0082 DATE: 08/10/15 PROJECT NAME: CHEVRON SITE ADDRESS: 14415 TUKWILA INTERNATIONAL BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: MN& Xj jlv Building Division W �C, 4 Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: Fire Prevention ❑ Structural ❑ Planning Division ❑ Permit Coordinator Is DATE: 08/11/15 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/08/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0082 DATE: 07/23/15 PROJECT NAME: CHEVRON SITE ADDRESS: 14415 TUKWILA INTT BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C&P 44 -1I1! Building Division Fire Prevention ❑ Planning Division ❑ ;)I �/ Public Works Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 07/28/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/25/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Q1 REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED:-/ Departments issued corrections: Bldg X Fire ❑ Ping ❑ PWX� Staff Initials: 12/18/2013 City1\L' ♦ itJ1Vl\ of Tukwila sBmITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. r Date: 8 r' I �/ 1 Plan Check/Permit Number: u Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: p /� r,1 -f FT p( - o A/( �1 ;7 n� / j r / /� Project Address: _l 44/ � / �--t T 1 Vll ll A ,�A ayjl -72 P %� , 1� U V I TJ Contact Person: T� & 1� F�— A L tK Phone Number: /-9P � Summary of Revision: Cof,'�VCITI-P Cow Sheet Number(s): "Cloud" or highlight all areas of revision including date Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on H:\Applications\Fortns-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Revised: May2011 �J v1VLA: 9s Permit Center Building Division o' .. .. CITY OF TUKWILA � z 2o6 431-3670 J , t Department of Community Development Public Works Department 6300 Southcenter Boulevard, Tukwila, WA 98188 2o6 433-0179 Telephone: (2o6) 431-367o FAX (2o6) 431-3665 Planning Division 1908 ' E-mail: tukplanpci.tukwila.wa.us 2o6 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: 1?(9 la — On 9-Z STATE OF WASHINGTON) ss. COUNTY OF KING ) states as follows: [please print name] i. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.ogo applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number / 3, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction w k. LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 Owner/Owner's Agent* Signed and sworn to before me this day of /��✓� s� ,20IS� PUBLIC in Residing at Name as commissioned: for the State of Washington County My commission expires: 651a9//Y 18.27.ogo Exemptions. The registration provisions of this chapter do not apply to: i. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; io. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician;; or an electrical trainee -meeting the requirements of chapter,) 9.28. RCW to perform plumbing work that is incidentally, directly, -and immediately appropriate to thelike-in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by -a certified electHeiari while performing plumbing work. " Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. 01 INSPECTION RECORD �"y� Retain a copy with permit 00 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: CXJ Type of Inspection: f Address: Date C H Special Instructions: ,�jn Date Wanted: �% 2 p.m. Requester: Phone No: Approved per applicable codes. orrections required prior to approval. COMMENTS: -)6 LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Mi INSPECTION RECORD Retain a copy wit(4 h permit f&jT—o I TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Ty of Inspe ion: p� Ald_rgss:�� ' //..�� D to Calldg Special instructions: 414 Date anted• a.m. /0 LS-- C- p.m. Requester: Phone No: Inspector: Date T� �`- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit P6 l5 �� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projectt:/ C�1t tJr/L�l �f Type of Inspe�jtion: e nCu 0 r1 Address: Date Called: Special Instructions: Date Wanted: a.m. Z 1 - lfS p.m. Requester: Phone No: oApproved per applicable codes. LJ Corrections required prior to approval. Inspector: �/J Date: l/ AA< �?- Z / s l Z5"" El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. AM INSPECTION RECORD jc) Z Retain a copy with permit I)pg /5 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: cl��� Typ of Inspection: P/gym d Address: Date Called: Special Instructions: Date Wanted: a.m. -26-16 p.m. Requester: Phone No: ❑ Approved per applicable codes. OCorrections required prior to approval. Inspector: Date 5 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. /A INSPECTION RECORD Retain a copy with permit �� IN CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro' t: hX6jV -k1 Ty p of inspection: j k F Address: / / �- ll�t�liGWlhl �!�'�l Date Called: Special Instructions: Date Wanted: a.m. ��- p.m. Requester: Phone No: ❑ Approved per applicable codes. 121 Corrections required prior to approval. [1W REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit l INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Ty6 of Inspjction Address: lclql ��GtJ� ��CVW/ X1061 Date Called: Special Instructions: ,�AA �`��' Date Wanted: a.m. � 2-el p.m. Requester: Phone No: ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Z, -& Date: C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. REVISED PLUMBINGLAYOUT SCALE 1/4" =1'-0" C,p SCALE N.T.S. Cp NN CO W,�T�TRNGERET cNN�c TQTp Tp � T N .� S�PpIY�NERw ��`I C lei � TD Q �xl el z I �V�- I� yl- - �f� 1 1/2" REVISIMS O�IP�` I I - Ito i all be made to 0W. Scope U I, q cf 1•'! -1 M%+�taut price approval of 3y1�1� gp nwision. Q I �NbASRUV INT L Nt and #390,1 PT Apt °R �GP M y. � City of Tukwila BUILDING DIVISION G2TY PLUMBING FIXTURES DRAIN SIZE VENT SIZE FIXTURE UNITS TOTAL FIXTURE UNITS 51ZE H.W. SIZE G.W. I WATER GLOSET(W.G.) 3" (P 3" (P 5 3 --- 1/2" I LAVATORY I-1/2"0 1-1/2"(P 1 1 1/2" I/2" I 3 COMP. SINK 2110 2110 3 3 1/2" 1/2" I GREASE INTERCEPT. 2110 2111P --- --- --- AP TOTAL EQUIVALENT FIXTURE UNITS : 7 EQUIVALENT IVALENT FIXTURE UNIT TABLE SCALE SIZING FOR WASTE, VENT & WATER SEPARATE PERMIT REQUIRED FOR: �.L'Cim A3 eedrw 0 Piurnt*g fir&s Piping City of TukrAla CORRECTION LTR# 1 - .WED FOR OMPLIANCE DROVED AUG 14 2015 City of Tukwila BUILDING DIVISION M611 2015 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA AUG 10 2015 PERMIT CENTER 3 "' r I S 0 0 a a t� O Q N d) > N 4 0 � S �1 client PARAS, INC. 0/0 DAVID MALIK TUKWILA CHEVRON 14415 PACIFIC H15HWAY SOUTH TUKWILA, WASHINOTON (206) 541-5355 Project REMODEL/ADDITION 14415 PACIFIC HIGHWAY SOUTH TUKWILA, WA5HINGTON Sheet Description REVI5ED PLUMBING LAYOUT EQUIVALENT FIXTURE UNIT TABLE WA5TE/VENT/WATER RISER DIAGRAM drawn by M. FO5TER check by L55 /55MAGVEIGH Scale date AS SHOWN 05/0-1/2015 discipline job number 2014-M4 Sheet Number FD— I 1f