Loading...
HomeMy WebLinkAboutPermit PG15-0089 - PROLOGIS - GAS PIPING TO ROOFTOP PACKAGE UNITPROLOGIS - UPLAND TI 1139 ANDOVER PARK W PG15-0089 is City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 3523049102 Permit Number: PG15-0089 Address: 1139 ANDOVER PARK W Issue Date: 8/19/2015 Permit Expires On: 2/15/2016 Project Name: PROLOGIS - UPLAND TI Owner: Name: AMB PROPERTY CORP Address: 60 STATE ST STE 1200 C/O RE TA, BOSTON, WA, 02109 Contact Person: Name: HEATH HAMBLEN Phone: (253) 939-5501 Address: 4102 B PLACE NW, AUBURN, WA, 98001 Contractor: Name: UNIVERSAL REFRIGERATION INC Phone: (253) 939-5501 Address: 4102 "B" PL NW, AUBURN, WA, 98001 License No: UNIVER1159RF Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: INSTALL GAS PIPING TO NEW ROOFTOP PACKAGE UNIT FROM EXISTING MAIN LINE Valuation of Work: $2,100.00 Fees Collected: $126.76 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Center Authorized Signature:W�/ f 1� WPermit Date: l/ ` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print ture: Date: l Name: flfiy7 C�U �� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 " http://www.Tukwi]aWA.gov SITE LOCATION Site Ten, Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: or office use onl PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" PROPERTY OWNER Name: _ IO 1S Zac.• Address: 11 City��' •�`� 4 S te: Zip- %% CONTACT PERSON — person receiving all project communication Name: Heath Hamblen Address: 4102 B Place NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email: heath@universalrefrig.com Kine Co Assessor's Tax No.:S52 Number: Alp, Floor: u New Tenant: ❑✓ .....Yes ❑..No PLUMBING CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B Place NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 939-5501 Contr Reg No.: UN]VERI 159RF Exp Date: 04/01 /2012 Tukwila Business License No.: BUS-0993124 ao Valuation of Project (contractor's bid price): $ 2100 . Scope of Work (please provide detailed information): j #3 A Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code):/ / Utility Purveyor: Water: _ �U Sewer: H:Wpplicatiorts\Forrrts-Applications On Line\201 I ApplicationsTlumbing Permit Application Revised 8-9-11.do« Revised: August 2011 Pagel of 2 bh Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water cooler head Lavatory Urinal Water beater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease intercevtors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch 51 mm diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O Z M 7�E AGENT: Signature: 4/ Date: 3 S Print Name: /-/ E9 40,01E.5 Day Telephone: (253) 939-5501 Mailing Address: 4102 B Place NW Auburn WA 98001 City State Zip H:VApplications\Pomis-Applications On Unc\2011 Applications\Plumbing Pemut Application Revised 8-9-11.dom Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS• QUANTITY PAID PermitTRAK $628.81 EL15-0671 Address: 1139 ANDOVER PARK W Apn: 3523049102 $86.31 ELECTRICAL $82.20 PERMIT FEE MULTI-FAM/COMM 11000.322.101.00.00 0.00 $82.20 TECHNOLOGY FEE $4.11 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.11 M15-0101 Address: 1139 ANDOVER PARK W Apn: 3523049102 $415.74 MECHANICAL $399.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $287.30 PLAN CHECK FEE R000.322.102.00.00 0.00 $79.95 TECHNOLOGY FEE $15.99 TECHNOLOGY FEE R000.322.900.04.00 0.00 $15.99 PG15-0089 Address: 1139 ANDOVER PARK W Apn: 3523049102 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.88 TOTAL Date Paid: Tuesday, August 04, 2015 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 49787 Printed: Tuesday, August 04, 2015 3:57 PM 1 of 1 (r-')"p�7 SYS7EM5 INSPECTION RECORD Retain a copy with permit IP&L5- o�q IN NLCXN No. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: � Type of Insp �><ion��. dress: ((3y 61%r Art 0 . Date Called: Special Instructions: e Date Wanted: a.m. "J l� p.m. Requester: Phone No: Inspector: Date: It—e REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 104 INSPECTION RECORD Retain a copy with permit IP615--007 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: - f Type of In pection: Ad1dr3 park � Date C tl d: Special Instructions: A -AA Date Wanted: a.m. p.m. Re ues er: cje—b Phone No: 2S3 Inspector: Dat�yCam- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. D INSPECTION RECORD Retain a copy with permit _dd1 ®r, ION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProjeSt: , a C l Type of Inspe lion: ` �� l� Address: If I Date Called( SpecialInstructions: /tM"! Date Wante a.m. — p.m. Requester: Phone No: RA REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0089 DATE: 08/05/15 PROJECT NAME: PROLOGIS - UPLAND TI SITE ADDRESS: 1139 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: hw(/ Aa 0� Building Division b 4J Fire Prevention ❑ Planning Division ❑ AN W t� Public Works Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 08/06/15 Not Applicable ❑ Structural Review Required ❑ (no approvallreview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/06/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 UNIVERSAL REFRIGERATION ITT Page 1 of 2 Home Inicio en liSpanol Contact. Safety Washington State Department of Labor & Industries UNIVERSAL REFRIGERATION INC Search L&I �� a�r� A-'L Indcx Help i41y Secure I &I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO BOX 614 AUBURN, WA98071-0614 Principals 253-939-5501 GATES, CHRISTOPHER A, PRESIDENT KING County GALVIN, BRYAN S, VICE PRESIDENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. Business type 600 599 723 Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..................................- Meets current requirements. License specialties COMMERCIAL/INDUSTRIALIREFRIG License no. UNIVER1159RF Effective — expiration 12106/1985— 04/01/2016 Bond ................ AMERICAN STATES INS CO $6,000.00 Bond account no. EX903622 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance American Economy Insurance Co $1,000,000.00 Policy no. 01 C179965210 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=LNIVERI159RF&SAW= 8/19/2015