Loading...
HomeMy WebLinkAboutPermit PG15-0095 - CENTURYLINK - MOP SINK AND FAUCETCENTURYLINK 6101 S 180 ST PG15-0095 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.Tukwi[aWA.Rov PLUMBING/GAS PIPING PERMIT Parcel No: 3523049120 Address: 6101 S 180TH ST 101 Project Name: CENTURYLINK Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028, TUKWILA, WA, 98138 Contact Person: Name: JUMAR NEWMAN Address: 6846 48 AVE N E , SEATTLE, WA, 98115 Contractor: Name: CLEARVIEW MECHANICAL INC Address: 6846 48TH AVE NE, SEATTLE, WA, 98115 License No: CLEARM1051134 Lender: Name: Address: "I , DESCRIPTION OF WORK: Permit Number: PG15-0095 Issue Date: 9/4/2015 Permit Expires On: 3/2/2016 Phone: (206) 527-8515 Phone: (206) 527-8515 Expiration Date: 11/3/2016 REMOVE EXISTING SHOWER, REPLACE WITH MOP SINK AND FAUCET IN THE SAME LOCATION Valuation of Work: $6,000.00 Fees Collected: $163.16 Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr or the performance of work. I am authorized to sign and obtain this development permit and agre o th onditions attache 1015M ermit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSP',C ONS REQUIRED ' • ` Permit Inspection Line: (206) 438-9350 1 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://ww-vv.TukwilaWA.gpv Plumbing/Gas Permit No. Project No. Date Application Accepted: 'T� Date Application Expires: /Fnrnfirrp vco -A') PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 352304-9120 Site Address: 6101 South 180th ST, Tukwila, WA.. 98188 Suite Number: NSA Floor: I Tenant Name: Century Link New Tenant: ❑ .....Yes m ..No PROPERTY OWNER Name: Century Link Address: 12550 26th AVE NE City: Seattle State: WA Zip: 98125 CONTACT PE communication ON —person receiving. all project Name: Jumar Newman Address: 6846 48th AVE NE City: Seattle State: WA Zip: 98115 Phone: (206) 527-8515 Fax: (206) 527-7967 Email: jumar@clearviewmechanical.com PLUMBING CONTRACTOR INFORMATION Company Name: Clearview Mechanical Inc. Address: 6846 48th AVE NE City: Seattle State: WA Zip: 98115 Phone: (206) 527-8515 Fax: (206) 527-7967 Contr Reg No.: CLEAW105I P4 Exp Date: 11/03/2016 Tukwila Business License No.: BUS-0995927 Valuation of Project (contractor's bid price): $ 6,000 Scope of Work (please provide detailed information): Remove existing Shower, replace with a Mop Sink and Faucet in the same location. Building Use (per lnt'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: H:\Applications\Forms-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8.9-1 I.docc Revised: August 2011 bh Sewer: Pagel of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 1 Rain water system -per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler(per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backfiow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction - In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional.period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING R OR AUTHORIZED AGENT: Signature: Newman Mailing Address: 16846 48th AVE NE Date: Day Telephone: (206) 527-8515 Seattle WA 98115 City State Zip H:1ApplicationslForms-Applications on Line12011 ApplicalionsMumbing Permit Application Revised 9-9-1 Ldocs Revised: August 2011 Page 2 of 2 bit DESCRIPTIONS PermitTRAK PAID $163.16 PG15-0095 Address: 6101 S 180TH ST 101 Apn: 3523049120 $163.16 PLUMBING $156.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $93.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $31.38 TECHNOLOGY FEE $6.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5978 R000.322.900.04.00 0.00 $6.28 $163.16 Date Paid: Friday, August 21, 2015 Paid By: JUMAR NEWMAN Pay Method: CREDIT CARD 00114G Printed: Friday, August 21, 2015 11:30 AM 1 of 1 SYSTEMS INSPECTION RE Retain a copy with INS CTION NO. -ORD permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje . • Z' .;CA / Type of Inspection* Address: fh Date Called: Ithlo Special Instructions: Date Wanted: a.m. 1 P.M. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �6-(-5 -dig fj PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prolectt, r � Type of Inspectio : &tom ctl� Add n. � t � 0 �J I # (® 1 Date Called: Special Instructions: Date Wanted: a.m. -1 ^ 7T J _ p.m. Requester: Phone No: 13— EJ FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0095 DATE: 08/21/15 PROJECT NAME: CENTURYLINK SITE ADDRESS: 6101 S 180 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Public Woks Structural ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator 01 DATE: 08/25/15 Structural Review Required ❑ DATE: DUE DATE: 09/22/15 Approved with Conditions R- Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CLEARVIEW MECHANICAL 1N0 Page 1 of 2 Home lnicio en Espanol Contact Safety Washington State Department of Labor & Industries CLEARVIEW MECHANICAL INC Owner or tradesperson Principals LEAVER, GREGORY E W, MANAGER WONG, BENSON D, AGENT BELL, TRACY W,SECRETARY (End: 10/09/2014) Doing business as CLEARVIEW MECHANICAL INC Search L&I A-Z Index Help Ivly Secure L&I Claims & Insurance Workplace Rights Trades & Licensing 6846 48TH AVE NE SEATTLE, WA 206-527-8515 KING County WA UBI No. Business type 601 655 738 Corporation Governing persons GREGORY EW LEAVER TRACY WAYNE BELL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CLEARM1051 P4 Effective — expiration 10/24/1995-1110312016 Bond ................. RLI INS CO $12,000.00 Bond account no. LSM0095756 Received by L&I Effective date 08112/2009 10/01 /2009 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy no. CWP2843929-25 Received by L&I Effective date 09/22/2014 10/01/2013 Expiration date 10/01/2015 Insurance history https:Hsecure.Ini.wa.gov/verifyIDetail.aspx?UBI=60165573 8&LIC=CLEARMI05 I P4&SAW= 9/4/2015 MECHANICAL SCHEDULES 91 F, VFD SCHEDULE SYMBOL LOCATION EQUIPMENT SERVED MANUFACTURER MODEL NO. ELECTRICAL MOTOR HP DISCONNECT BYPASS SERVICE SWITCH AC LINE REACTORS ENCLOSURE REMARKS VFD-EF-32 ROOF EF-32 SQUARE D E-FLEX EFDEH4VYA07B08AO9 460/60/3 2 YES YES YES 5% NEMA-3R SEE NOTES VFD-EF-37 ROOF EF-37 SQUARE D E-FLEX EFDFH4VYA07BO8AO9 460/60/3 5 YES YES YES 3% NEMA-3R SEE NOTES VFD-EF-38 ROOF EF-38 SQUARE D E-FLEX EFDFH4VYA07BO8AO9,� 460/60/3 5 YES YES YES 3% NEMA-3R SEE NOTES NOTES: (1) FURNISH TO ELECTRICAL FOR MOUNTING AT ROOF VFD 05/19/15 DAMPER SCHEDULE LOCATION EQUIPMENT SERVED FUNCTION DAMPER TYPE BLADE ARRANGEMENT SIZE W X H DESIGN AIRFLOW CFM MANUFACTURER AND MODEL LEAKAGE CLASS REMARKS RTU 16A SUPPLY DUCT RTU-16A ISOLATION AIRFOIL PARALLEL 46 X 65 20,000 RUSKIN CD-60 AMCA 1A BATTERY ROOM SUPPLY AIR DUCT BATTERY RM BALANCING AIRFOIL OPPOSED 32 X 32 6,000 RUSKIN CD-60 AMCA 1A FIT WITH QUADRANT HANDLE FOR MANUAL BALANCING RTU 16 RETURN AIR RTU-16 ECONOMIZER AIRFOIL PARALLEL 72 X 27 20,000 RUSKIN CD-60 AMCA 1A RTU 16 OUTDOOR AIR RTU-16 ECONOMIZER AIRFOIL PARALLEL 60 X 28 20,000 RUSKIN CD-60 AMCA 1A RTU 17 RETURN AIR RTU-17 ECONOMIZER AIRFOIL PARALLEL 72 X 27 20,000 RUSKIN CD-60 AMCA 1A RTU 17 OUTDOOR AIR RTU-17 ECONOMIZER AIRFOIL PARALLEL 60 X 28 20,000 RUSKIN CD-60 AMCA 1A EF-37 DUCT BELOW ROOF EF-37 ISOLATION AIRFOIL OPPOSED 54 X 54 20,000 RUSKIN CD-60 AMCA 1A EF-38 DUCT BELOW ROOF EF-38 ISOLATION AIRFOIL OPPOSED 54 X 54 20,000 RUSKIN CD-60 AMCA 1A EXHAUST FAN SCHEDULE SYMBOL BMS NUMBER SYSTEM SERVED CONSTRUCTION TYPE DRIVE TYPE OPPERATING CONDITIONS MOTOR OPER. WEIGHT LBS DESIGN BASIS REMARKS EFF % HP INSULATION TYPE NOMINAL RPM VOLTS/ PHASE FLOW CFM STATIC IN WC SPEED RPM BHP EF-32 reuse existing BATTERY ROOM ROOF DOWNBLAST BELT 6500 0.75 580 1.3 2 F 1750 460/3 320 GREENHECK GB-300 SEE NOTES 1, 2, 3 EF-37 EF-04026-RT37 ECONOMIZER RELIEF ROOF LOUVERD PH BELT 20000 0.375 277 2.72 5 F 1750 460/3 600 GREENHECK LBP 54 SEE NOTES 2 & 3 EF-38 EF-04026-RT38 ECONOMIZER RELIEF ROOF LOUVERD PH BELT 20000 0.375 277 2.72 5 F 1750 460/3 600 GREENHECK LBP 54 SEE NOTES 2 & 3 NOTES: (1) EF32 REPLACES A SMALLER EF-7, PROVIDE NEW CURB AND DUCT WORK. BACKDRAFT OR ISOLATION DAMPER. (2) FURNISH FANS WITH ROOF CURBS (3) PROVIDE VFD COMPATIBLE MOTORS COORDINATE LARGER ROOF PENETRATION, ELECTRICAL, AND CONTROLS. FAN RUNS CONTINUOUSLY AND DOES NOT REQURIE A AIR BALANCE SCHEDULE SYMBOL EXISTING OR NEW UNIT LOCATION UNIT SERVICE AREA TOTAL SA CFM TOTAL RA CFM MIN OA CFM NON- RECIRC EXH CFM ZONE PRESSURIZATION CFM REMARKS RTU-16 EXISTING ROOF PCOR & BATTERY 20,000 20,000 500 500 500 RTU-17 EXISTING ROOF PCOR & BATTERY 20,000 20,000 500 500 500 RTU-16A NEW ROOF PCOR & BATTERY 20,000 14,000 5,000 6,000 - 6000 LOST TO CONTINUOUS BATTERY ROOM EXHAUST EF-32 NEW ROOF BATTERY - - - 6,500 BATTERY ROOM EXHAUST, VFD MODULATES SPEED EF-37 NEW ROOF PCOR - - - 20,000 ECONOMZIER EXHAUST, VFD MODULATES SPEED EF-38 NEW ROOF PCOR - - 20,000 ECONOMZIER EXHAUST, VFD MODULATES SPEED NOTES: (1) RTU 16A, 16 ,& 17 UNITS ARE TIED TOGETHER IN A COMMON SUPPLY; DUCT TO PROVIDE N+1 COOLING OF 40,000 CFM. 16A OPERATES CONTINUOUSLY ALONG WITH EITHER 16 OR 17. 6,000 CFM OF SUPPLY AIR GOES INTO THE BATTERY ROOM WHERE IT IS EXHAUSTED BY EF-32. ECONOMIZER EXHAUST FANS EF-37 & 38 REMOVE THE OA SUPPLIED BY RTU'S 16 & 17 DURING ECONOMIZER MODE BY MODULATING TO MAINTAIN SPACE PRESSURE. r AIR HANDLING UNIT SCHEDULE UNIT ELECTRICAL SUPPLY FAN EXHAUST FAN COOLING COIL ENERGY CODE FILTERS FAN FAN DRIVE FAN MAX FAN FAN FAN PRESSURE SUPPLY FAN MOTOR FAN DRIVE SPEED BLADE MOTOR MOTOR MOTOR TOTAL SENS AIRSIDE TYPE SYMBOL AREA EXISTING MANUFACTURER SUPPLY MINIMUM SEE NOTE 4 OPERATING BSME # REMARKS TSP ESP QTY BHP HP FLA EFF VOLTAGE/ VELOCITY ENTERING I LEAVING ROWS F FINS PD EER IEER PRE -FILTER TOTAL FILTER SERVED OR NEW AND MODEL AIRFLOW OA VOLTAGE/ FLA MCA MOCP TYPE QUANTITY TYPE SPEED SPEED EFF DISCHARGE QUANTITY TYPE RPM PITCH BHP NOMINAL EFF VOLTAGE/ CAPACITY CAPACITY WEIGHT CFM CFM PHASE RPM RPM % EACH % PHASE DEGREES PHASE MBH MBH FPM F DB/WB F DB/WB FPI IN WC LBS RTU-16 PCOR & BATTERY RM EXISTING TRANE 20,000 0 460/3 1 1 20 EXISTING DX COOLING COIL 8.6 8.9 6,300 RTU-17 PCOR & BATTERY RM EXISTING TRANE 20,000 0 460/3 1 1 20 EXISTING DX COOLING COIL 8.6 8.9 6,300 RTU-16A PCOR & BATTERY RM NEW BASIS ANON RN050 20,000 6,000 460/3 130 135 1 150 BACKWARD CURVED 2 DIRECT 1545 1800 66 PLENUM 4.14 2.25 1 2 1 9.70 1 15 1 21.0 0.9 460/3 2 DIRECT 1136 20 1 1.33 2 87.5 460/3 603 458 457 75/64 53.7/53.5 4 1 14 0.52 11.1 12.7 2" MERV 8 4" MERV 15 6,840 16A 01026-RT40 SEE NOTES NOTES: 1. BASIS OF DESIGN SELECT RTU-16A IS 0.49 INCH WC CLEAN FILTER LOSS WITH AN ADDITIONAL 0.35" DIRTY FILTER ALLOWANCE 2. PROVIDE RTU-16A WITH 100% OUTDOOR AIR CAPABILITY, WITH RELIEF TO OCCUR AT ROOF HOOD. E_PAR XF E FERi"M(T 3. PROVIDE RTU-16A WITH FAN SHAFT GROUNDING AND INTERGRAL VFD'S FOR SUPPLY AND EXHAUST FANS. R QUIRED FOR: REVISIONS 4. EXCEEDS MINIMUM PERFORMANCE REQURIED BY WASHINGTON STATE ENERGY CODE TABLE C403.2.3(1) OF 10.0 EER AND 10.1 IEER �ll�chani�t NO changes shall he made to the scope c nww 1n1: . ; ,.1 MECHANICAL ABBREVIATIONS AFF ABOVE FINISHED FLOOR MFGR MANUFACTURER APPROX APPROXIMATE MIN MINIMUM BOP BOTTOM OF PIPE NC NORMALLY CLOSED CBBD COUNTER BALANCED BACKDRAFT NO NORMALLY OPEN DAMPER O/C ON CENTER CFM CUBIC FEET/MINUTE OSWF ON-SrrE WORK FORCE CLG CEILING OA OUTSIDE AIR CONC CONCRETE PD PRESSURE DIFFERENCE COND CONDENSATE PF PLUG FAN CONN CONNECTION PG PRESSURE GAUGE CONTT CONSTRUCTION PSIG POUNDS/SQUARE INCH, GAUGE CONTR CONTRACTOR PRESS PRESSURE CHWS CHILLED WATER SUPPLY RA RETURN AIR CHWR CHILLED WATER RETURN RECIRC RECIRCULATION db DRY BULB REG REGISTER DIA DIAMETER REQD REQUIRED DIM DIMENSION RPM REVOLUTIONS/MINUTE DN DOWN RM ROOM DWG DRAWING SA SUPPLY AIR EA EXHAUST AIR SP STATIC PRESSURE ELECT ELECTRICAL SPEC SPECIFICATIONS ENGR ENGINEER SQ SQUARE EQUIP EQUIPMENT SS STAINLESS STEEL ESP EXTERNAL STATIC PRESSURE STD STANDARD EXH EXHAUST STRUCT STRUCTURE, STRUCTURAL F DEGREES FAHRENHEIT SW SWITCH FD FLOOR DRAIN_ TD TEMPERATURE DIFFERENCE FLR FLOOR TEMP TEMPERATURE FPI FINS PER INCH THRU THROUGH FPM FEET PER MINUTE TMTR THERMOMETER FV FACE VELOCITY TSP TOTAL STATIC PRESSURE GA GAUGE TSTAT THERMOSTAT GAL GALLON TYP TYPICAL GPM GALLONS/MINUTE V VENT HP HORSEPOWER VEL VELOCITY KW KILOWATT VD MANUAL VOLUME DAMPER LB POUND W WASTE MAX MAXIMUM wb WET BULB MBH BTUH IN THOUSANDS MECH MECHANICAL MECHANICAL LEGEND NEW DUCTWORK EXISTING DUCTWORK DEMOLITION DUCTWORK Of ® RA/EA RETURN AIR, RELIEF AIR OR EXHAUST AIR DUCT / RISER ® SA SUPPLY AIR DUCT / RISER y 11 t a1:9 DUCT TURNIING DOWN NEW EQUIPMENT EXISTING EQUIPMENT CEILING MOUNTED RETURN OR EXHAUST GRILLE / REGISTER CEILING MOUNTED SUPPLY DIFFUSER (THROW) 1 1 SIDEWALL RETURN GRILLE AP ACCESS PANEL O WALL MOUNTED THERMOSTAT O WALL MOUNTED SPACE PRESSURE SENSOR MAJOR EQUIPMENT CALLOUT EF-4 MINOR EQUIPMENT CALLOUT O NOTE REFERENCE COND CONDENSATE CONTROL VALVE, MOTORIZED L� FLOOR DRAIN BUTTERFLY VALVE R=1.5D D DN UP Y-STRAINER BALL VALVE BALANCING VALVE EXISTING FIRE/SMOKE DAMPER MOTORIZED DAMPER VOLUME DAMPER COMBINATION FIRE/SMOKE DAMPER 90' HEEL TAP TAKEOFF (RECTANGULAR DUCT) TEE ECCENTRIC TRANSITION (A = 15' MAXIMUM) RECTANGULAR -TO -ROUND TRANSITION (A = 15' MAXIMUM) DUCT OFFSET, DOWN DUCT OFFSET, UP MITERED ELBOW (WITH TURNING VANES) RADIUS ELBOW ❑ Piumbing Q-6as Pik City of Tukwila GENERAL MECHANICAL NOTES 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS, ELBOWS, ETC., WHICH MAY BE REQUIRED FOR PROPER INSTALLATION OF WORK. PROVIDE ADDITIONAL BENDS AND/OR OFFSETS AS REQUIRED TO COMPLETE WORK AT NO ADDITIONAL COST. 3. COORDINATION OF WORK WITH OTHER TRADES EMPLOYED IN THE PROJECT IS MANDATORY. CAREFULLY EXAMINE THE SPACE AVAILABLE TO DETERMINE FINAL ROUTING AND ELEVATIONS OF SERVICES. SHOULD REARRANGEMENT OR RE-ROUTING OF LINES OR PIPING BE NECESSARY, PROVIDE FOR APPROVAL THE SIMPLEST LAYOUT POSSIBLE FOR THAT PARTICULAR PORTION OF THE WORK. 4. THE EXISTENCE OF ANY PIPING, DUCTS OR OTHER SERVICE FACILITIES ARE SHOWN IN A GENERAL WAY ONLY. THE CONTRACTOR SHALL VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE OF ANY SUCH FACILITIES PRIOR TO THE SUBMISSION OF HIS BID. 5. CONTRACTOR TO REMOVE MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 6. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 7. ALL WORK TO BE INSTALLED PER CURRENT CENTURYLINK STANDARDS. 1 "vrt:a culiuiiig ulvision_ I NOTi Rc islons will require a new plan submittal and may include addiMotW plan review tees. ISSUES REVISIONS NO. DESCRIPTION DATE BY nness inu►irn nrk nr-ku A A /A-/ /4 G r9 1 1 I VU/O VVVNLR RLVICr1 v-r/vi/ Zvi Iwu 2 I 100% OWNER REVIEW j 05/15/15 RJJ 3 BID SET _ 05/18/15 RJJ _-- i I, -- - --- - ----._ --- -- - -- ....... - ---- - _ i --- i i RLEu�. Permit�+ I fan raview approval is subject to errors and cmissba i %pproval cif a :,;- ruction documents don riot audwfiza it; . ation cf eny adopted c oc I pp. oved Fiald Copy an is By: Dater--f�/.5 City of Tuila BUILDING DIVISION RECEIVED CITY OF TUKWILA. AUIJ 21" 2015 PERMIT CENTER 150241 1600 7IH AVE. SEATH.E. WASMCM OFFICE OF THE DR. PROPERLY LIM. KDW S A *.,44 , CIS iRIEN'l 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p.206.547.1940 f.206.547.8212 j www.kdw.net Is I f " aztbW W* daN rAt a astod to orAcAsd p.el. R Y mat 1Q m bF d ON OONSULTAMr FF64 REVI'EVVED FOR CODE COMPLIANCE APPROVED AUG 2 8 2015 wr` City of Tukwila BUILDING DIVISION �® ®® BUILDING ID FLOIR2 ®® �® BMILBNG NAVE TUKWILA CYBER CENTER Smu ADDRESS 6101 SOUTH 180TH STREET CenturyLinkl Cny, STATE TUKWILA, WA 98188 AIM MECHANICAL LEGEND AND NOTES COMMEMIT NAME KDW SALAS O'BRIEN No fff JCL ck% mAw PqE 04/07/15 CHECIM fff RJJ MAM NO REVISED BY SCU AS NOTED m 32"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90 32"0E0 32" 0 SQUARE TO ROUND TRANSITION 3202 AIRFOIL DAMPER WITH MANUAL QUADRANT ACCESSIBLE FROM LID OF BATTERY ROOM -.-- 3202 LID ABOVE BATTERY RM 3202 FSD ELBOW WITH AIRFOIL TURNING VANES BATTERY RM L 2DMOP SINK l SCREENED SUPPLYa1 AIR OPENING 7 FIRE RATED ENCLOSURE, REF ARCH FLAG NOTES: D INTENTION IS TO DUMP UP TO 6,000 CFM OF SUPPLY AIR INTO THE AISLE IN FRONT OF THE RECTIFIERS. ADJUST SCREENED OPENING SIZE AFTER WALL DEMOLITION DETERMINES AVAILABLE SPACE. 2D SEE M2.1. MECHANICAL SECTION SCALE: 1/4" = 1'-0" r- @ BATTERIES 6,500 CFM I © RECTIFIERS /-- EF-32 MECHANICAL DETAIL SCALE: NONE MD-20 AIR FLOW DIAGRAM SCALE: NONE CUT BACK EXISTING RC AND INSULATION 6" AR CURB LOCATION. BUIL WEATHERTIGHT AT ALL ' CUT OPENING IN EXIST DECK. SEE STRUCTUR EXISTING ROOF TRUSS AC-1 RTU-4 RTU-2 RECEIVE© CITY OF TUKWILA AUG 2 1' 2015 PERMIT CENTER EXHAUST FAN GREENHECK LBP54 EXHAUST FAN BASE PREMANUFACTURED INSULATED CURB, SECURED PER STRUCT ROOF MEMBRANE PATCH UP AND OVER CURB RIGID INSUL TO MATCH EXISTING (AVERAGE R-23) STEEL ANGLES PER STRUCT TEMPERATURE SENSOR IN AIR STREAM ACCESS FROM ABOVE r I\ L— V I .J I V I V ,J NO. DESCRIPTION DATE BY _ 1 60% OWNER REVIEW 04/07/15 RJJ 2 I 100% OWNER REVIEW 05/15/15 RJJ 3 BID SET 05/18/15 RJJ 1800 7M AVE. SEATH& WASH�IGTOM W CE OF DE DR PROPEM UM 7m, faeem� ma0dmd enr dam mt r� Iy�a�mtad�i4.elo�erw dry � j OONSU MT H N KDW &a, e, gO'BRIEN' 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 P.206.547,1940 f.206.547.8212 www.kdw.net I i REVIEWED FOR DE COMPLIANCE s ,APPROVED 7a AUG 2 8 2015 City of Tukwila BUILDING DIVISION 150241 ®® ®® 13UMNG ID FLOOR ® ® ® ® 13UILMNGNAME TUKWILA CYBER CENTER y.7 ADfm 6101 SOUTH 180TH STREET Ce ntu ry L i n k ra—msmi TUKWILA, WA 98188 DmRImm MECHANICAL DETAILS AND DIAGRAMS CONSULTANT NAME CONSULTANT NAME KDW SALAS O'BRIEN DRAWN IY JCL CASE NUMER JOB'. 150241 04/07/15 oRAa�+c Pro. SHEET ram. M5.1 FUMED L AS NOTED