HomeMy WebLinkAboutPermit PG15-0105 - ANDERSON RESIDENCE - ROUGH-TRIM AND GAS PIPING716 INDUSTRY DR
PG15-0105
City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 2523049008 Permit Number: PG15-0105
Address: 716 INDUSTRY DR Issue Date: 9/28/2015
Permit Expires On: 5/10/2016
Project Name: TAMARA ANDERSON
Owner:
Name: NCWP ANDOVER EXECUTIVE PARK
Address: 810 NW MARSHALLS ST #300 ,
PORTLAND, WA, 97209
Contact Person:
Name:
CHRIS PARADISO
Address:
2608 SECOND AVE #541, SEATTLE,
WA, 98121
Contractor:
Name:
PARADISO MECHANICAL
Address:
2608 2 N D AVE #541, SEATTLE, WA,
98121-1212
License No:
PARADM*981LP
Lender:
Name:
Address:
Phone: (206) 251-6854
Phone:
Expiration Date:
DESCRIPTION OF WORK:
ROUGH -TRIM 50 GALLON ELECTRIC WATER HEATER, TRIPPLE SINK, TRENCH DRAIN, DISHWAHER AND CLOTHES
WASHER
REVISION #1: ADD GAS PIPING TO ORIGINAL SCOPE OF WORK
Valuation of Work: $26,500.00 Fees Collected: $282.76
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature: Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this rmit does not presume to give authority to violate or cancel the provisions of any other
state or local laws r g ating construction or the performance of work. I am authorized to sign and obtain this
development i to the conditions attached to this permit.
Signature: Date:( y S
Print Name: �� 7
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000
GAS PIPING FINAL
8004
GROUNDWORK
8004
GROUNDWORK
1900
PLUMBING FINAL
9002
ROUGH -IN GAS PIPING
8005
ROUGH -IN PLUMBING
City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone:206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 2523049008 Permit Number: PG15-0105
Address: 716 INDUSTRY DR Issue Date: 9/28/2015
Permit Expires On: 3/26/2016
Project Name: TAMARA ANDERSON
Owner:
Name:
NCWP ANDOVER EXECUTIVE PARK
Address:
810 NW MARSHALLS ST #300 ,
PORTLAND, WA, 97209
Contact Person:
Name:
CHRIS PARADISO
Phone: (206) 251-6854
Address:
2608 SECOND AVE #541, SEATTLE,
WA, 98121
Contractor:
Name:
PARADISO MECHANICAL
Phone:
Address:
2608 2ND AVE #541, SEATTLE, WA,
98121-1212
License No:
PARADM*981LP
Expiration Date: 8/15/2016
Lender:
Name:
Address:
DESCRIPTION OF WORK:
ROUGH -TRIM 50 GALLON ELECTRIC WATER HEATER, TRIPPLE SINK, TRENCH DRAIN, DISHWAHER AND CLOTHES
WASHER
Valuation of Work: $26,500.00 Fees Collected: $217.76
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition: 2012 National Electrical Code: 2014
International Residential Code Edition: 2012 WA Cities Electrical Code: 2014
International Mechanical Code Edition: 2012 WAC 296-46B: 2014
Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012
International Fuel Gas Code: 2012
Permit Center Authorized Signatu
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws reg g construction or the performance of work. I am authorized to sign and obtain this
development permi and ag a onditions attached to this permit.
Signature: Date: /Z01s
Print Name:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: `PLUMBING/GAS PIPING PERMIT CONDITIONS'
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
8004 GROUNDWORK
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
CITY OF TUKWI
Community Development Department
• Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
litip:/iwww.Tukwi]aWA.aov
SITE LOCATION
Plumbing/Gas Permit No. V (0 l �- — 0
Project No.
Date Application Accepted: ^
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
.�.� King Co Assessor's Tax No.: 2-5z3/'>1tdk9QW
Site Address: Suite Number: f-� Floor: (sc
TenantName: ������ New Tenant: M..... Yes El.. No
PROPERTY OWNER —p Name:
Address:
City: — �—v�/ 1, J� State: \xVA Zip:
CONTACT PERSON — person receiving all project
communication
Name: CVkZVS --�:�.R-AQSO
Address:2Go!E5 -Z�� ANiz
City: — State:\,,_)� Zip: q 121
• 1.
Phone: ,,, ` �J Fax:
rEmail:GL'��,J��``��Lt
Yk.-.
PLUMBING CONTRACTOR INFORMATION
Company Name:
Address: "2-(p0�
City: c�3 State:,jj Zip: �g12 l
Phone 7 ZSl / ��4 Fax:
Contr Reg Nog` Exp Date: 1 2c� t6
Tukwila Business License No.:<)
Valuation of Project (contractor's bid price): $ Z Co I Soy
Scope of Work (please provide detailed information): Zov64# --r,z
Tci kS t NY— , D1k« -0\Slil wAsl��) � �-c�H� " A-SV6! --
Building Use (per Int'1 Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
H:\Applications\Forms-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-1 l.docz
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/ is piping outlets being installed and the quan jelow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
I
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections 1-5
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
rotections over 5
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
ease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch 51 mm diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will. be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN
Signature
G OW R AUTHf:.A
Print Name: C,4ZkS ' jPATuQlS'6 Day Telephone:�� 7 Sl GeSA
Mailing Address: 2 Co Qa 2°'° A\ 9F"r?'
City State Zip
H:\Applications\Forms-ApplicationsOnLine\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011 Page 2 of 2
bh
Date Paid: Wednesday, December 30, 2015
Paid By: CHRIS PARADISO
Pay Method: CREDIT CARD 022411
Printed: Wednesday, December 30, 2015 10:40 1 of 1 CI?W SY57EM5
AM
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$217.76
PG15-0105 Address: 716 INDUSTRY DR Apn: 2523049008
$217.76
PLUMBING
$209.38
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$135.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$41.88
TECHNOLOGY FEE
$8.38
TECHNOLOGY FEE
TOTAL'. 11
R000.322.900.04.00
0.00
$8.38
Date Paid: Tuesday, September 08, 2015
Paid By: CHRISTOPHER PARADISO
Pay Method: CREDIT CARD 013011
Printed: Tuesday, September 08, 2015 8:05 AM 1 of 1
MT
SYSTEMS
3
INSPECTION RECORD
o Retain a copy with permit S
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING [DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project.
Type�upellr lei (
/
Ad`ores :
Date Called:
Special Instructions:
A
44l
Date W n ed: %C
7/�s/N
a.m.
p.m.
Requester:
Phone No:
jlnspector:je'-7,, Iuate:rq_ ZZ— I / I
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
r&
INSPECTION RECORD 6
Retain a copy with permit 71
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Typ of Insg4on: f
c �� 0
P- f f
Addr
-7(e s:
Date Called:
Special Instructions:
Date Wanted: a.m.
P.M.
Requ seer:
Phone No:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
v�
INSPECTION RECORD
Retain a copy with permit f
SP CTIQN NO. PERMIT NO
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro'e-ctt:''
/ —me - �a'll
Type o speciio/n: ,
LC /i / >
A>��ss: ��
Date ailed:
Special Instructions:
Date Wanted: a.
P.M.
Requester:
Phone No:
1 i Approved per applicable. codes. E Corrections required prior to approval.
u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Insp tion: /
f
Address:
l 6 IL
Date Called:
Special Instructions:
n
Date Wanted:
a.m.
Requester:
if
s-
Phone No: r
%66
�/
ElApproved per applicable codes. LJ Corrections required prior to approval.
`-I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit I P&(T 0 i(U
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspectio /
Address:
Date Called:
r
Spetial Instructions:
Date Wanted a.m.
p.m.
Requester.: c ,
ri 0
Phone No:
lek -IF
.�
caG w'"
Iinspector: I/ — Iuatel, p ,_�5— I
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
MPD TM-N �11 4 -f t:E:) - �S - 0\0S7
� 1 0
. lk
Perm. Ft No.
Ph-, - ivjew appruwll is subject W errors and omissions.
I
A,pprovai &Wtl�rueiion documents does riot aut
the Violation of ;,,,-Iy a opto-, horize
U r ordinance. Receipt
Of QPPrcv0l,--j* fic-ld C Py and on i0l"s is acknom',edged:
py: —
.y R-EF
1 40
117 IT
r
n c a I
C! C;4 icy]
b i n g
C:is Aping
REVISIONS
No changes sh.nij
rn,' 3 to the scm*
Of prior approvel of
G '!dinr
UP, *,
C'!-f submita I
-T—=Tm1t-- "
k4boj000
r2
TAA<Y--
"'ity of � " ,
BUILDING 1VI:
KIWILWED FOR
CO E E COMPLIANCE
APPROVED
I EC 2 3 2015
AJ
G ty of Tukwila
13UILPjNG DIVISION
RECEIVED
CITY OF TWINILA
DEC 1 4' 2015
PERMIT CENTER'
P��S•Dlo5
�-' you- 4 v off--
b
op-0
'JpLv%
I It
REA
�) r-A)
6la 04� 0 STV,,
REVIEWED FOR
CODE COMPLIANCE
APPROVED
DEC 2 3 2015
City of Tukwila
BUILDING DIVISION
RC -!V,o
CITY Or TUKWILA
DEC 1 4'2015
PERMIT CENTER
1. 3`' C- o 1Z�F
3. a3" S , V
S-
3x 2 coNc�o
� .
31,11'rx 2"
q .
2 f 40ts�o
t o •
3x Z V%<1F
tt ,
2y
C,pM$o
1Z
3x
t3.
3y
t
14.3
V
Q� -rev
15.
2y
"t - 1-TIAr
L6. `rve %OL- ?NMW— VA -W
CA) Div SV43 a i
OC -, e Q+ -PZa11 r4
OID `ccAz— SNAL
C) MACkIr
FILE COPY
Permit No. 12GIL-0106.
.
Plan review approval is subject to errors and omissions.
Approval of construction documerKs does not authorize
the violation of any adopted code or ordnance. Receipt
of approved Field Copy conditions is a knowle W:
5f.
Date: 4 17
City of Tukwila
BUILDING DIVISION
PF-41AA T
"ZOO IRED FOR:
OfAecnaracel
rGas Prang
City of Tukwila
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a now plan submittal
and may include additional plan review fees. r
C1
O 4 ul
v,/� Acr-"-?S�LZ7 LM .
A
3.1
2.
M
Q0
3�
FOR
SEP 2 4 2015
Qf T
WlWfNG DIVISION
1
Z"
Z,_'
"'IfY OF Ti;
SEP 21 2015
-;ERMIT CENTER
3"
wriea., Fit
ORRECTll W
LTRiV
P,gtS • 0105
13
1
To Si. A4 -
'W
Z
4;
v
IV
YL (S)
(2) vt wam.-
v W�6tf MA<q1N3
no_
FOR
SEP 2 4 2015
City ofTukwlM
BUILDING DM810tJ
RACE, -;IV ED
CITY OF TUMLA
SEP 21 2015
"IERMIT CENTER
T4".
S'�vtc�
61•B.
.0
7on
Rit*H C E IVill D
CITY OF TUK iLA
SEP 21 2015
PERMIT CENTER
7g
w,
r= F5 2 r
2'r
r -
r
Z,, E
I:! IE
tn E
ta
b! E
E
tl
—E
—E
E
tl E
E
E
E
E
tn E
El
r
r
E
E
r
tj
tq,
Ir
E
LS
I
—A
WY
In
9t
2 4
"MAW"V . . . . . . . . . . .
IL L—
Es.
R
ZIA
21E
Z'-t.
It
rn
V
E a
qL may
gio.lo
a
0
AUTOMATIC TRAP PRIMER VALVE
" 695 SERIES PrimePerfeer
SPECIFICATION
Where replenishment of water in floor drain traps is required; trap primer valves
shall be 1/2" FIP inlet x 1/2' MIP outlet, automatic trap primer valves which activate
with a 10 PSIG pressure drop between 30-150 PSIG. Water release shall be
factory set. Trap primer valve shall have large port openings and a non-
corrosive brass finish. Must be UPC/IAPMO listed, and ASSE certified to the
ASSE 1018 standard.
WORKING PRESSURE
30-250 PSIG
OPERATING PRESSURE
Activates with a 10 PSIG pressure drop at 30-150 PSIG
Vil.j L E
ITEM # SUBMITTED
JOB NAME
LOCATION
ENGINEER
CONTRACTOR
PO# TAG
IMVIEVVED FOR
91041PLIANCE
00
VED
SEP 2 4 2015
INSTALLATION
Install to a convenient 1h"-11/2" nominal water line, nearest the rap oft lovT
served. Install in the upright, vertical position only. Install at le @�
above the grid of the floor drain or the flood rim of the sink or ��!
serves. Install near plumbing fixtures to insure a full pressure drop of 10 P I or
more. If the trap primer is installed too far upstream in the system, the pressure
drop may not be enough for activation. To help prevent sediment buildup, install a
vertical loop that rises above the supply line tee. (see figure 1) Flush trap primer
branch line prior to installing the trap primer. Install MIP adapter. Thread on trap
primer. Install FIP union to bottom. Use PTFE tape sealant on both connections.
Do not use pipe dope. Do not solder or braze directly to trap primer or fittings
installed in trap primer. Water discharge is factory set —no adjustment is required
on normal installations. However, for static pressures over 100 PSI, adjustments
may be necessary. First loosen the nipple locknut (10, below), then turn the nipple
(19, below) counter -clockwise until the trap primer starts dripping, turn the nipple
clockwise 1/4-turn, and re -tighten nipple locknut.
DIMENSIONS
Inlet
1/2" FIP
Outlet
1/2" MIP
Diameter
23/4"
Length
51/4"
COMPONENTS
1: Cap, brass -plated Zamac No. 3
2: Stainless steel screws
3: Diaphragm
4: Valve stem spring
5: Valve stem nut
6: rubber valve disc
7: Valve stem guide
8: Body, brass -plated Zamac No. 3
9: Nipple seat washer
10: Nipple locknut
RE_CE1V"E0 trap
CITY OF TUK ILA
SEP 2 1 2015
PERMIT CENTER
11: Vacuum breaker
12: Sediment screen
13: Diaphragm stop washer
14: Diaphragm spring retainer
15: Valve stem
16: Diaphragm spring
17: Valve washer ""''�
��
18: Diaphragm adjustment nuj p R R ECT i���/
19: Brass nipple
TR#
Create Item N
695-01
ACCESSORIES
695-Y52 = wye splitter
695-D20 = two 1/4" male sweat branches
695-030 = three 1/4" male sweat branches
695-D40 = four 1/4" male sweat branches
695-D432 = two 114" male sweat branches,
two spin -closed branches
Moc rertrcct
898
%- ac ' 1
695-01
' cold water suppl y
trap primer
vacuum breaker
gravity line
.— floor drain
figure 1
695-D432F = four 1Fi" FIP branches with two plugs
695-D4325 = two 1h" female sweat branches,
two spin -closed branches
Sioux Chief Manufacturing Company I P: 1.800.821.3944 1 F: 1.800.758.5950 1 www.siouxchief.com
V441�i-(A05-
Product Specification
Click here to print this document / export to PDF
Part Description:
35GPM GREASE INTERCEPTOR
Part Number:
3935A03
SUBMITTAL SHEET
Canplas Industries Ltd Canplas LLC
500 Veterans Drive 11402 East 53rd Ave.
Barrie, Ontario, 1-800-461-5300 Denver, CO 1-888-461-5307
TOP VIEW
��{{ I
I
I
(a ASME
G _
FRONT VIEW
SIDE VIEW
Part B Part UPC Size (Inches) Ctn aty
Ctn Bar Cade Ctn Wt (K®s) Ctn Wt (Ibs) Skid Cubic (m) Skid Cubic ((t) Ctns/Skid
3935A03 662671390103 3 1
10662671390100 23.97 52.84 1.98 69.80 6
Dinro w—(Inch-)
A B C D E F
G
31.00 23.50 5.20 1220 17.40 28.75
21.25
SVVED FOR
I CQ, IMPUANCI
�t �0 OVZD
SEP 2 4 2015
CRY OfTulk"I
WILDING DIVISION
CITY OF TuY<VlitLA
SEP 2 12015
PERMIT CENTER
� oRRECa
L TR#
P&I ILY_ 0109
http://www.canplaspiumbing.com/DesktopModules/Canplas.Prodmenus/Submittal Sbect.aspx?PartID=39275
�r About Us I Price Lists I Rep Locator I Contact Us I Corporate Home
search Advanced Search
L' PLUMBING
DWV Fittings Specialty Plumbing Endura Grease Management Sewer Downloads
Sign up for our eNewsletter
S@lectCountry: Canada _Gj - -- -•--_ _� _ __ _____._ _ ..-
Grease Interceptor Calculator
Downloads
U.S. Price Lists
Canadian Price Lists
Literature
Sentry Software Download
Warranty Info
Warranty Registration
Terms of Sale
10 Credit Application
Grease Interceptor
Calculator
Canplas Plumbing
F DWV Fittings
10
Specialty Plumbing
Endura Grease
Management
Sewer
Moro From Plumbing
10
Product News
Upcoming Events
0 Press Releases
Industry Links
Downloads
Warranty
Endura Warranty
Registration
Terms of Sale
Credit Application
Export Pricing
Pricing Announcement
10 Binder Registration
Try it on Canplas
[Endum Gre2se Unte rce ptop Sizing C211cul2$oc
1 Measure vaur sinks. (Nota- inrJude frP.Pstandlnn wall and mnn sinks in this sertinnl
Length
(inches),
Width Depth
(inches), .(inches) _
Cubic Capacity
(Inches.)_
Volume
(US gallons)
l ompartment/BOWI 1
18 .I
1.a
111_
I 6¢4
CompartmenUBowl_2
19 I
la I
It
I FT564__
Compartment/Bowl_3
l s_ . _. Ito
I t l
I 3564
Sub Total-Sink1
[�00
10692
46.286 Gallons
Compartment/Bowl 1
o�—Il�e
_11
_J
C.p_artment/Bowl2-
�o—I
UO IMo
-
INo
I®
CompartmenUBgwl 3
_ ICI
O�—I
Sub Total -Sink 2
r---
L
Gallons
Co_m,partmen_t/Bowl1.
—IF
—1
Compartment/Bowl 2
F-7—IUo
IPo _
IL9 1
CompartmenVBowl3—II—I
Sub Total - Sink 3
t�OL�J�u----
o Gallons_
Maximum Discharge
�'0���
46 286. G_ailons,
Drainage Load A
(Max Discharge x 0.75) 34.715 Gallons
2. Select a '1' or '2' minute drain period.
Note: Where possible it is recommended to design based on a t minute drain period. Drain Period is
however a convenience factor allowing a more compact (lower capacity interceptor to be used in the
calculated application. The trade off is greater frequency of maintenance of that more compact solution.
Formula assumes a 1 minute drain period - For minute enter'2'�� _ inute_
Actual Drainage Load 34.715
Gallons/Minute (GPM)
3a. Sizing a Dishwasher - Gravity Discharge.
Note: Dishwashers can be connected to a GI only if allowed by local code. Each dishwasher will require a
seperate GI.
Convert to GPM x Separation Factor (10min) 0 Gallons/Minute (GPM)
3b. SJzLn9 a Dishwasher - Pumped Discharge.
Manufacturers specified Peak/Max_Discharge GPM
3c. Add any Additional Appliances/Drains.
Note: For floor drains/sinks take the volume of water produced by the number of hose bibs (i.e. 1.5-2.0 GPM
Der 3/4 inch faucet)
( _ Floor Sink 1/0ther Appliance jo iGPMf
Floor Sink 2/0ther Appliance F0
FloorSin k-3/OtherAppliance. _ Ip
Total Additional Discharge (Dishwasher plus AdditionalAppliances/Drains)` o GPM
LGrease Interceptor Capacity Required L 5.-_ . GPM )
P
the above cell displays "Flow Rating Exceeded" consider using a 2 minute drain period. Ifstillshowing
Flow Rating Exceeded' contact your national Canplas Customer Service location for assistance. These
are listed below for your convenience. _
This application requires a Canplas Endura r° ? Note: Sufhx'S' denotes OPTIONAL spigot
Part Code: �41h,..1' ' 4 ,,-Y - version Flow Control Device
Alternate Parts: NB: 3 Inch hubs standard, 4 Inch hubs also available,
product code 393SA04 (S)
Canplas Customer Service Canada: 1:800-;46_i-5300 U.S.A.: 1-888-461-5307
Click here to print this document / export to PDF
Product Warranty Terms of Use PrivacyPolicy Site Map
canp1Y3 .0AlldXit ornpay
City of Tukwila
Department of Community Development
September 15, 2015
CHRIS PARADISO
2608 SECOND AVE #541
SEATTLE, WA 98121
RE: Correction Letter # 1
PLUMBING/GAS PIPING Permit Application Number PG15-0105
TAMARA ANDERSON - 716 INDUSTRY DR
Dear CHRIS PARADISO,
Jinn Haggerton, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these
comments.
• (GENERAL NOTE)
PLAN SUBMITTALS: (Min. size I Ix17 to maximum size of 2406; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) All Structural Drawings and structural calculations sheets to be stamped .(original signed wet stamp,
not copied) by Washington State licensed architect, structural engineer or civil engineer.
(BUILDING REVIEW NOTES)
1. Provide manufactures specifications with sizing and installation information for the grease trap. Indicate if this is
an above or below floor unit. Grease trap shall be located where it is easily accessible for maintenance.
2. Show providing a trap seal primer for all floor -sinks and floor drains. Trap primer supply connection shall be
located to where it can be accessed for maintenance.
3. I could not find a building permit for this tenant space or previous use of this tenant space. A building permit
shall be required where walls, ceilings and roof penetrations are opened for plumbing and electrical installation in
the wall framing and for any alterations or additions to the building framing. Please provide information
specifically what it being altered and indicate if this space has a certificate of occupancy. An occupancy
certification is provided after the building permit is completed. Final inspection for building shall not be approved
until the plumbing has final plumbing inspection approved.
4. Provide clarification and an explanation for this space indicating type of occupancy (Previous occupancy).
Indicate what type of business shall be conducted for this space. A health department permit shall be required
where food is prepared for public consumption.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
As Znn 4Z,,,,.1,n,,,,1a,,-4 c,,;*..4/n0 . T,.l,..;1 oR IRR . M 7nA_A? 1 1K7n . V-,.')nA A? 1 2441Z
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail
or by a messenger service.
If you have any questions, I can be reached at (206) 433-7165.
Sincerely,
41�
elipley
Permit Technician
File No. PG15-0105
6300.cnuthwntnr Rnulovnrd SY4ity #lnn a Tij")iln Wnchinotnn 9R1RR • Phnna ?n6-431-3671) a Fnr ?n6-a71-3665
PERMIT COORD COF11
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG15-0105 DATE: 12/17/15
PROJECT NAME: TAMARA ANDERSON
SITE ADDRESS: 716 INDUSTRY DR
Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # X Revision # 1 after Permit Issued
DEPARTMENTS:
Building Division 0
Public Works 10
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
Fire Prevention ❑
Structural ❑
Planning Division ❑
Permit Coordinator ❑
DATE: 12/17/15
Structural Review Required ❑
DATE:
DUE DATE: 01/14/15
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
��•iii,'. COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG15-0105 DATE: 09/23/15
PROJECT NAME: TAMARA ANDERSON
SITE ADDRESS: 716 INDUSTRY DR
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
Building Division Fire Prevention
Public Works ❑ Structural
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
❑ Planning Division ❑
❑ Permit Coordinator ❑
DATE: 09/24/15
Structural Review Required ❑
DATE:
DUE DATE: 10/22/15
Approved with Conditions
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG15-0105 DATE: 09/08/15
PROJECT NAME: TAMARA ANDERSON
SITE ADDRESS: 716 INDUSTRY DR
X Original Plan Submittal
Response to Correction Letter #
DEPARTMENTS:
k11 �110
Building Division
14k J(4 �IIO
Public Works
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
Revision # before Permit Issued
Revision # after Permit Issued
Fire Prevention ❑
Structural ❑
Planning Division ❑
Permit Coordinator 0
DATE: 09/10/15
Structural Review Required ❑
DATE:
DUE DATE: 10/08/15
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
YV—
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PROJECT NAME: -TAM MA WA" ' b r , PERMIT NO: PPIq U I U
SITE ADDRESS: '11U IU ORIGINAL ISSUE DATE:
REVISION LOG
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
4-
Summary of Revision: To L%MAI
W
Received by:
u
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
City of Tukwila
Department of Community Devel
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: l --zd � ,q, Plan Check/Permit Number T(S 1 � 1 — 0 L os
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
Revision # 1 after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:
Project Address:
Contact Person: Phone Number:
Summary of Revision:
CUST�tT� �2---�Ca
1 \ V
�-,..:
,F1 Y U)- i ui', i L A
DEC 14 2015
Sheet Number(s)•
"Cloud" or highlight all areas of revision including date of revision
�
Received at the City of Tukwila Permit Center by: W V
❑ Entered in TRAKiT on
U
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: Plan ChecWPermit Number: PG 15-0105
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner �� � TlW1LA
❑ Deferred Submittal #
Project Name: TAMARA ANDERSON ->Ral= GNtA
Project Address: PG15-0105
Contact Person: C#45 ytso Phone Number: ?,ffo ZS'i i6$S4
Summary of Revision:
CLOP A` MIt -4,, L_ 1—�V1 CA-r—r-CD Cr— -k->LANS
Ste-. 341�rk— Wpap
S-FCA4a W cM Aug X\—9, kxp.." a�
tNG OV1=5NIN6
�w O uAL3 PD MkXA v,)G No Sy mm— 4%Ar-,� GES, WiF
-I&J I I NV Te? MAC (\ " -&-2 NOD
�'�LcylwS '�tv> T S WAyz-&X)s, , kS
Sheet Number(s): -1�-2- RNIS;2D 6k zIl I ixns
"Cloud" or highlight all areas of revision including Ote of rev' con
Received at the City of Tukwila Permit Center by:
❑ Entered in TRAKiT on
W:\Permit CemeffemplatefformARevision Submittal Porm.doc
Revised: August 2015
PARADISO MECHANICAL
Page 1 of 2
4nWashington State Department of
Labor & Industries
PARADISO MECHANICAL
Owner or tradesperson
Principals
PARADISO, CHRIS, OWNER
Doing business as
PARADISO MECHANICAL
WA UBI No.
601 389 402
License
Home Inicio en .Espanol Contact
Safety Claims & Insurance
2608 2ND AVE #541
SEATTLE, WA 98121
206-251-6854
KING County
Business type
Individual
Search L&IJii
A-`L Index Help My Secure L&I
Workplace Rights Trades & Licensing
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor. Active.
Meets current requirements.
License specialties
PLUMBING
License no.
PARADM'981 LP
Effective — expiration
06/17/2002— 08/15/2016
Bond
................
Wesco Insurance Co
$6,000.00
Bond account no.
46W BO64899
Received by L&I
Effective date
08/06/2015
06/15/2015
Expiration date
Until Canceled
Bond history
Insurance
American States Insurance Co
$1,000,000.00
Policy no.
01 C175319120
Received by L&I
Effective date
03/02/2015
04/01 /2016
Expiration date
04/01/2016
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
................
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
........................................ _...............
No license violations during the previous 6 year period.
https:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=601389402&LIC=PARADM*981LP&SAW= 09/28/2015