Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG15-0127 - WASHINGTON PLACE / HOTEL INTERURBAN - UNDERGROUND PLUMBING AND PIPING
WASHINGTON PLACE - UNERGROUND 223 ANDOVER PARK E PG15-0127 Parcel No: Address: ON of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-93SO Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT 0223100090 Permit Number: PG15-0127 223 ANDOVER PARK E Issue Date: 11/20/2015 Permit Expires On: 5/18/2016 Project Name: WASHINGTON PLACE - UNDERGROUND Owner: Name: WASHINGTON TOWERS LP Address: 18230 E VALLEY HIGHWAY #195 , KENT, WA, 98032 Contact Person: Name: MICHAEL BARRETT Address: 4230 B ST NW, AUBURN, WA, 98001 Contractor: Name: APOLLO SHEET METAL INC Address: PO BOX 7287, KENNEWICK, WA, 99336 License No: APOLLSM187MK Lender: Name: Address: Phone: (253) 872-5151 Phone: (509) 586-1104 Expiration Date: 4/9/2016 DESCRIPTION OF WORK: COMPLETE UNDERGROUND PLUMBING AND PIPING FOR NEW HOTEL/APARTMENT This underground permit is for DWV only. Valuation of Work: $115,000.00 Fees Collected: $1,928.56 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: ( S I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the con ' 'on ttached to this permit. Signature: Date: i(L4 l Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: Applicant shall apply for a separate Public Works permits for installation of two Detector Double Check valves Assemblies (DDCVAs) on the fire suppression lines fire inside the building and domestic water service backflows. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND 4 �1 CITY OF TUKWIL Community Development Department Permit Center- • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No.T GIs — Qa� Project No. Date Application Accepted: Date Application Expires: —t use PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 022310-0090 Site Address: 223 Andover Park E Suite Number: Floor: Tenant Name: Washington Place, LLC New Tenant: © .....Yes []..No PROPERTY OWNER Name: Washington Place, LLC Address: 18230 E. Valley Highway #195 City: Kent State: WA Zip: 98032 CONTACT PERSON — person receiving all project communication Name: Michael Barrett Address: 4230 B Street NW City: Auburn State: WA Zip: 98001 Phone: (253) 872-51.51 Fax: (253) 872-5930 Email: mike.banfett@apollomech.com Valuation of Project (contractor's bid price) 115,000 Scope of Work (please provide detailed information): Complete underground plumbing and piping for new Apartment/Hotel. Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: PLUMBING CONTRACTOR INFORMATION Company Name: Apollo Mechanical Address: 4230 B St. NW City: Auburn State: WA Zip: 98001 Phone: (253) 872-5151 Fax: (253) 872-5930 Contr Reg No.: APOLLSM187MK Exp Date: 04/09/2016 Tukwila Business License No.: BUS-0995010 Sewer: H:1ApplicationstFornu-Applical ions On Line%2011 ApplicationsTlumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or g, ,iping outlets being installed and the quantity , w: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler(per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet CDD Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: _ Print Name: Michael Barrett Mailing Address: 4230 B Street NW Date: 10/30/2015 Day Telephone: (253) 852-5151 Auburn WA 98001 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK PAID $1,557.68 PG15-0127 Address: 223 ANDOVER PARK E Apn: 0223100090 $1,557.68 PLUMBING $1,483.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $1,451.00 TECHNOLOGY FEE $74.18 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: ' .. • • R000.322.900.04.00 0.00 $74.18 Date Paid: Friday, November 20, 2015 Paid By: CHRISTINE LEE Pay Method: CREDIT CARD 00284D Printed: Friday, November 20, 2015 11:04 AM 1 of 1 Ut 7 SYSTEMS Date Paid: Friday, October 30, 2015 Paid By: AMY HIGHTOWER Pay Method: CREDIT CARD 052322 Printed: Friday, October 30, 2015 2:26 PM 1 of 1 I?WSYS7EM5 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PFo orlt � � / TYPe.gf nspect�On: i AddresA. 6 V �.� Date Called:. Special Instructions: u� Date Wanted: / a.m. s- -'�,, p.m. Re jester: �S A e4— Phone No: Inspector: Date ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection 3 INSPECTION RECORD Retain a copy with permit I TION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of In ection: % Address: - ,vim Date Called: / 2 Special Instructions: 4ifMl Date Wanted: a.m. � p,m, Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: awto L! c r' O ^. Inspector: Date: 4— REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD (TI Retain a copy with permit7 INS N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: 01 Address: 919. ave i'1�r Date Called: Z I Special Instructions: Hate Wanted: a.m. p.m. Requester: l Phone No: Inspector: Date/-,>, r� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. i INSPECTION RECORD Retain a co with rmit P� �`�N-7 SPECTION NO. copy "�PfRMI NO. CITY OF TUKWIL.A BUILVid IVISf�`�� 6300 Southcenter Blvd., #100, Tukwila. WA 98188���F (206) 431-3670 Permit Inspection Request Line (206) 438-9350 G� Pr je/� 6je%� —1 r ln pection: TyRe,o1PWV Address-j.nf� �O't0� Date Called: Special Instrucctions: W5F / f{ � p�` '(ItrJe Date Wanted: D� a.m. p.m. Request r: Phone No: S r Inspector: Date:j� s ` ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. c Cast Iron Submersible Sump PUMPS ,4 - - � . 114 hp 1-112" Discharge } The most advanced 114 hp pump available! �.- Features: h�, x # • Unique one-piece cast iron housing "' • Peripheral port inlets eliminate • ,%.� .�.. _,..:., . ram• ,.� =-`� �' r bottom suction .' , • 304 stainless steel intake plate °' �, • Quick -disconnect 10' standard power cord allows replacement ' of cord in seconds without .,;,,•;;,�;�/"` �' breaking seals to motor. (25' length optional) w. - °'- r _ • Available in three switch styles �•. 1 including Liberty's VMF switch Modes: 240 Manual 241 Wide -Angle Float, YearWarranty Quick Disconnect 243 Wide -Angle Float, Series Plug -,� 247 VMF, Vertical Magnetic Float `� Wide -Angle Floats are mercury -free, mechanically activated. 240-SERIES A 1/4 hp Sump Pump for Professionals! ALL MODELS FEATURE: • Rugged 1/4 hp motor, oil filled with thermal overload protection • 1/4" solids handling • 1-1/2" discharge • Hermetically sealed motor and switch cavities, and permanently lubricated bearings • Liberty's UNI-BODY casting - a solid, one-piece housing that eliminates the lower motor seal ring found on other pumps • Integral, mid -mounted "peripheral -port" inlets - eliminate bottom suction of debris and foreign material • Maximum Fluid Temperature:140OF MOTOR SPECIFICATIONS.- 1/4 hp 115V 6.0 amps 60Hz 3400 RPM Thermally Protected & Permanently Lubricated DIMENSIONAL DATA: Weight: 21 LBS. Height: 10" Major Width: 9.0" (manual model 240) Model 240 Manual, no switch Model 241 Quick -disconnect wide-angle float, Mmercury -free. Cerkfi�eof � P� MtMOtR ® c US Certified Specifications subject to change without notice. • Stainless steel volute intake plate, internally mounted. Will not corrode. • 8 vane, glass reinforced thermoplastic impeller, Non -clog design. • Quick -disconnect 10' standard power cord allows replacement of cord in seconds without breaking seals to motor. (25' length optional) For 25' cord option, add a "-2" suffix to model number. Example: 247-2 for Model 247 with 25' cord. • Fasteners - all non -corrosive stainless steel • Stainless steel rotor shaft PERFORMANCE CURVE 25 m 6 � 20 w c 15 cts 5 4 d ro 10 2 H r 5 0 5 0 10 15 20 25 30 35 U.S. Gallons Per Minute 28.4 55.8 85.2 113.5 Liters Per Minute Model 243 Wide-angle float with series (piggy -back) plug, allows manual operation of pump. Model 247 VMF VMF switch, magnetically operated vertical float - operates in a 10" diameter sump. Liberty Pumps • 7000 Apple Tree Avenue • Bergen, New York 14416 • Phone 800-543-2550 Fax (585) 494-1839 www.libertypumps.com Copyright © Liberty Pumps, Inc. 2011 All rights reserved. LLIT400-R10/11 2012 Washinqton State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Com fiance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug2015 Project Info Project Address: WASHINGTON PLACE Date 10/30/2015 223 ANDOVER PARK E. For Building Dept. Use __ .._.._ TUKWILA, WA98188 Applicant Name: GROUP WEST COMPANIES, PLLC Applicant Address: 3601 FREMONT AVE. N., SUITE 314, SEATTLE, WA 98103 Applicant Phone: 206-812-8886 __.... Project Description Briefly describe mechanical systems in the text box provided ❑ Total Bldg Performance Bldg Performance compliance includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis Summary forms required. ❑� New Building ❑ Building Addition ❑ Tenant Improvement] FIL I--�IVt �-� System I2Jtrofit No Systerp hanges CODE CONI DANCE APPROVED NOVotal � 2015 ' O19 City of Tukwila Mechanical Systems Summary BUILDING DIVISION! Equip ID Type of System (Note 1) Space(s) Served Compliance Path Heating and Cooling Fan Flow Controls Air Economizer (Note 2) Ventilation (Note 3) Energy Recovery Note 1 - Provide basic description of system type, for example: unitary rooftop air handler, built-up central air handler,' single -packaged, split system or packaged terminal air conditioner or heat pump; unit heater, warm -air furnace, electric resistance heater, 4-pipe fan coil, VRF system, energy recovery air handler, make-up air system, ground or water -source heat pump, etc. Note 2 - If taking an exception to air economizer, select exception taken from drop down menu and complete MECH-ECONO form. Summary definitions of each exception are listed in MECH-ECONO. Note 3 - If ventilation "Not applicable " is selected, provide explanation in Project Description box above. HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Water -loop heat pump ❑ No hydronic systems ❑ Hydronic heating ❑Geothermal Service Water Heating Systems Equipment Type (s) pC(`� �,, ❑ Hot water heating tank(s) ❑ Instantaneous [ f _N8 5`Ofn> T�Pems ❑ Dedicated boiler ❑ Heat exchange from space heat boiler or 6 ILP central hot water/steam Distribution Type (s) OCT 3 0 2015 ❑ Circulation System ❑ On -demand Mechanical Schedules ❑ Mechanical Plans ❑ MECH-EQ Form Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans a// applicable compliance information listed in MECH-EQ tables. Design Load Calculations ❑ Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 ❑ Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. Fan Power ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds Shp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.10 and MECH-FANSYS-DOC for requirements and exceptions. Commissioning Exception ❑ Commissioning will be provided for all applicable systems Summary Commissioning Exceptions: Describe means of eligibilty for commissioning exception (capacity, ❑Mechanical system(s) etc) for all systems noted as taking exception in Mechanical Systems Summary table. Refer to Section C408.2 and C408.4 for exceptions. ❑ Service water heating system(s) For systems requiring commissioning, Figure C408.1.2.1 Commissioning Compliance Checklist shall be submitted to the code official upon project completion. Low Energy and Semi -Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity, Btu/h Capacity, Btu/h Capacity, Compliance Type Location in Plan(s) Space(s) Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C101.5.2 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h-sf. Note 7 - Refer to Section C402.1.4 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 btuh/sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 2012 Washinaton State Enerav Code Compliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and all R1 Revised Auq 2015 Project Address WASHINGTON PLACE Date 10/30/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes GENERAL PROVISIONS Equipment Sizing & Performance na C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 Equipment and system Output capacities of heating and cooling equipment and systems do not exceed the next larger na C403.2.2 sizing available equipment size above the calculated loads; note exceptions taken Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable na C403.2.5 Minimum ventilation of being reduced to minimum requirement per IMC C403.2.3 & Equipment minimum Provide equipment schedules or complete MECH-SUM tables with e, capacity,efficient , P type, Y na C403.2.3.2 & efficiency test standard (or other efficiency source) for all mechanical equipment C403.2.12.1 na C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, and efficiency for all motors; note exceptions taken For all applicable systems > 5hp, provide system total nameplate hp in MECH-FANSYS-SUM na C403.2.10.1 Fan power limitation form For all applicable fan systems > 5hp, verify fan system motor hp or bhp complies with fan na C403.2.10.1 Fan power limitation power limits per Table C403.2.10.1(1), provide MECH-FANSYS form for each system Indicate fan motors specified are the smallest available motor hp size greater than fan bhp, na C403.2.10.2 Motor nameplate hp note exceptions taken na C403.2.10.3 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. & C403.2.13 na C403.2.3 Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit capacity Non-standard water-cooled Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard na C403.2.3.1 chillers operational conditions Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan na C403.2.12.1.2 towers open circuit cooling towers na C403.2.3 Forced air furnace and unit Indicate intermittent ignition or IID, flue/draft damper & jacket loss heaters Packaged electric Verify all packaged electric equipment that provides > 20,000 Btu/h cooling capacity and na C403.2.3.3 heating/cooling equipment heating is a heat pump, note in equipment schedule na C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria na C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems C403.2.4.1.1 Heat pump supplementary Indicate staged heating (compression/supplemental) and outdoor lock -out temperature is set na heat to 40°F or less na C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling na C403.2.4.3 Automatic setback and Indicate zone t-stat controls with required automatic setback & manual override shutdown na C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions C402.4.5.2 & OSA, exhaust, and relief air Indicate location of outdoor air supply intake, and exhaust and relief outlet dampers; verify na C403.2.4.4 dampers P Class 1 leakage rating and control type motorized or gravity); note exceptions taken 9 9 YP ( 9 Y); P Indicate location of return air dampers that are integral to economizer operation; verify na C402.4.5.2 Return air dampers motorized control and Class 1 leakage rating; note exception taken Indicate location of stairway and shaft vents, verify Class 1 leakage rated motorized dampers na C402.4.5.1 Stairway and shaft vents and method of activation na C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls na C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions na C403.2.4.6 Combustion heating Indicate modulating or staged control equipment Group R1 hotel/motel Indicate method for guest room temperature automatic setback (heating) & set-up (cooling), na C403.2.4.7 systems confirm adjustment of at least 5°F minimum. Group R2/R3 dwelling and Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback na C403.2.4.8 / E sleeping unit systems periods and 10°F deadband; note exceptions taken na C403.2.5.1 Demand controlled Indicate high -occupancy spaces and systems requiring DCV ventilation Indicate spaces requiring occupancy -based system control and method; or alternate means na C403.2.5.2 Occupancy sensors provided to automatically reduce OSA when partially occupied 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 PermitMechanical Plans ■ 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address WASHINGTON PLACE Date 10/30/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation system activation and na C403.2.5.3 dock/parking garage control method ventilation Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning na C403.2.5.4.1 Kitchen exhaust hoods method Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative na C403.2.5.4.2 Laboratory exhaust systems method taken (VAV, semi -conditioned makeup, or CERM calculation) na C403.2.6.1 Energy recovery (ER) - Indicate ventilation systems requiring ER, method & efficiency; note exceptions ventilation systems na C403.2.6.2 Energy recovery (ER) - Indicate on -site steam heating systems requiring energy recovery condensate systems na C403.2.6.3 Energy recovery (ER) - Indicate remote refrig. condensers requiring ER and use of captured energy cooler/freezer condensers Energy recovery (ER) - Indicate condenser systems requiring ER to pre -heat service water; indicate ER effectiveness; na C403.4.6 condenser systems note exceptions taken Variable flow control - Indicate fan and pump motors z 7.5 hp and the method of variable flow control (VSD or na C403.2.12 fans/pumps equivalent controls) Variable flow control - heat Indicate heat rejection equipment and cooling tower fans requiring variable flow control and na C403.2.12.1 rejection equipment method Indicate single zone fan systems requiring airflow reduction capability in response to reduced na C403.2.12.2 Large volume fan systems cooling or heating demand in a zone, or adjacent zones without separating walls, with > 10,000 CFM supply air; note exceptions taken Indicate method of cooling demand -based fan control for air conditioning systems > 110,000 na C403.2.12.2 Single zone AC systems Btu/h serving single zones Identify all DDC system input/output control points and indicate capability for trending and na C403.2.4.10 DDC system capabilities demand response setpoint adjustment Ducting Systems C403.2.7.1 & Indicate all ductwork constructed and sealed per IMC, C402.4 leakage requirements and IBC na C403.2.7.3 Duct construction vapor retarder requirements na 403.2.7.3.1- Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide test results to na test jurisdiction when completed na C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork Piping Systems na C403.2.8 Piping insulation Indicate R-value of insulation on piping na C403.2.8.1 1 Piping insulation exposed to Indicate method of protection from damage/degredation weather SIMPLE SYSTEMS Qualifying Systems Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, does not have active na C403.3 systems humidifcation or simultaneous heating/cooling na C403.3 Qualifying 2-pipe heating Verify 2-pipe heating -only system does not exceed capacity limits systems na C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers na C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule na C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) na C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA; note exceptions taken na C403.3.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with capacity > 65,000 Btu/h operation na C403.3.1.1.3 Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) controls 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 3 of 4 MECH-CHK, 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address WASHINGTON PLACE Date 10/30/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes COMPLEX SYSTEMS Complex System Economizers na C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule na C403.4.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) For eligible systems where water economizer may be provided in lieu of air economizer, na C403.4.1.1 Water economizer capacity indicate system is capable of 100% cooling capacity at 50°F db/45°F wb OSA Water economizer Indicate precooling coils and heat exchangers in water economizer system do not exceed na C403.4.1.2 maximum pressure drop pressure drop limit na C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water economizer systems operation Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating na C403.4.1.4 impact lenergy usage during normal operation Specific System Requirements na C403.4.2 & VAV fan control Indicate fans requiring variable flow control and method C403.2.12 na C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans; include at least one sensor per major duct branch sensors na C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most pressure setpoint VAV systems serving Indicate supply air systems serving multiple zones, method of primary air control, and zones na C403.4.5 multiple zones served; Indicate VAV or note exceptions taken C403.4.5 VAV systems serving For each air system terminal, indicate the maximum air flow rate of primary supply air during na multiple zones zone peak cooling and the maximum air flow rates during zone peak heating. na C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads Large capacity cooling Indicate method of multi -stage or variable control for building cooling system capacity > 300 na C403.4 systems tons na C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method na C403.4.3 Large capacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 Btu/h systems na C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers na C403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & isolation boilers when not in use na C403.4.3.6 & Variable flow control - Indicate pumps requiring variable flow control & method C403.2.12 pumps na C403.2.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method & C403.4.4 cooling towers Hydronic system part load Indicate heating & chilled water systems have the capability to automatically reset supply water na C403.4.3.4 controls temp AND reduce flow by >_ 50% for systems > 300,000 Btu/h na C403.4.3.2 Two -pipe changeover Indicate deadband, heating/cooling mode scheduling and changeover temperature range systems Water loop heat pump - Indicate capability of central equipment to provide min. 20°F water supply temp deadband na C403.4.3.3.1 deadband between heat rejection and heat addition modes na C403.4.3.3.2.1 Water loop heat pump - Indicate method used to limit system heat loss when heat rejections is not needed heat rejection, Zone 4 na C403.4.3.3.2.2 Water loop heat pump - Provide heat exchanger that separates cooling tower and heat pump loop heat rejection, Zone 5 C403.4.3.3.3 Water loop heat pump - Indicate 2-way isolation valve on each heat pump and variable flow control for systems with na isolation total pump power> 10 hp na C403.5 Walk-in cooler / freezer - Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters anti -sweat heaters na C403.5 / 6 Cooler / freezer - evaporator Indicate motor type for evaporator and condenser fans < 1 hp and condenser fans 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Permit Plans Checklist - Page 4 of 4 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address WASHINGTON PLACE Date 10/30/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes SERVICE WATER HEATING Service Water Systems Water -heating equip min. Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency na C404.2 efficiency source na C404.3 Temperature controls Indicate temperature controls have required setpoint capability na C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge na C404.5 Insulation underwater Indicate R-10 insulation under electric water heater tanks heater yes C404.6 Service water piping Indicate R-value of insulation on piping; note exceptions taken insulation UG-P0.1 na C404.7 / 8 Circulation systems and • Indicate shut-off capability based on occupancy and periods of limited demand heat trace shut-off Group R-2 service hot water Indicate method of usage metering for dwelling units served by a central service hot water na C404.9 meters system Pools & In -Ground Permanently Installed Spas Pool heating equip min. Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency na C404.10.1 efficiency source Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that na C404.10.1 / 2 Pool heater on / off controls operates independent of thermostat setting; note exceptions taken na C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required na C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F na C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use; note exceptions taken COMMISSIONING Specific System Requirements C408.2 Mechanical systems Indicate all mechanical systems to be commissioned; for those that will not be commissioned, na commissioning note exception taken Service water heating Indicate all service water heating systems to be commissioned; for those that will not be na C408.4 systems commissioning commissioned, note exception taken na C408.1.1 Commissioning plan Provide commissioning plan for all systems requiring commissioning; include in plan all required items per this section C408.2.2.1 & Air system and hydronic Include in commissioning plan that air and hydronic systems shall be balanced in a manner to na C408.2.2.2 system balancing first minimize throttling losses, then adjust to meet design flow conditions C408.2.2.1 Air system balancing Indicate devices that provide the capability to balance all supply air outlets, zone terminals and na devices equipment requiring system balancing C408.2.2.2 Hydronic system balancing Indicate devices that provide the capability to isolate, balance and measure flow for all hydronic na devices equipment requiring system balancing Mechanical systems Provide description of functional performance testing procedures for all applicable systems na C408.2.3 functional performance including: equipment, controls, economizers testing Service water heating Provide description of functional performance testing procedures for all applicable systems na C408.4.1 functional performance including: equipment, controls, pools and spas testing na C408.1.4 Systems operation training Indicate required systems operation training measures to be provided C408.1.2 & Documentation Indicate required documentation including: record documents, manuals, balancing reports, na C403.1.3 commissioning preliminary and final reports Indicate that Commissioning Compliance Checklist (Figure C408.1.2.1) is required upon na C408.1.2.1 Acceptance report completion of preliminary commissioning report inve rix ENGINEERING To: City of Tukwila — KC Ellis From: Emily Bettridge Project: Washington Place-U/G Plumbing Re: Permit #PG15-0127 Building Division Review Memo-11/4/15 Copy To: File, Patrick Strobridge, Sean Damon, Kevin Gutman, Mike Barrett KC Ellis, November 10, 2015 Project Number: 1430 The following is a response to the Underground Plumbing Permit review comments provided to the design team on November 4, 2015, by the City of Tukwila (reviewer, KC Ellis): 1. General Notes were modified to include references to details on sheet UG-P3.10. General Notes were also modified to update outdated sheet references. 2. Pool substrate system and details were deleted in accordance to RFI 66 3. Pool Drains and pool system are by Pool Contractor. A 4" Hub Drain was added to the Pool Equipment room per Pool Contractor's requirements. The Hub Drain is routed to the Sanitary Sewer. See Hub Drain Installation Detail 1/UG-P3.10 for airgap compliance. The following is a response to the Underground Plumbing Permit review comments provided to the design team on November 10, 2015, by the City of Tukwila (Public Works Department): 1. Note was added to all connections to Civil: "CIVIL TO TRANSITION TO INVERTS LISTED. SEE CIVIL DRAWINGS FOR COORDINATION." End of Memo CORRECTION LTR#__,Q_____ RECEIVED CITY OF TUKWILA NOV 10 2015 PERMIT CENTER 911 western Ave., Suite 406, Seattle, WA 98104 o P: 206.515.4004 F: 206.515.2026 4 www.inventrixeng.com I City of Tukwila Department of Community Development 5/3/2016 MICHAEL BARRETT 4230 B ST NW AUBURN, WA 98001 RE: Permit No. PG15-0127 WASHINGTON PLACE - UNDERGROUND 223 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/6/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/6/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: PG15-0127 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 9 Fax 206-431-3665 City of Tukwila Department of Community Development November 09, 2015 MICHAEL BARRETT 4230 B ST NW AUBURN, WA 98001 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG15-0127 WASHINGTON PLACE - UNDERGROUND - 223 ANDOVER PARK E Dear MICHAEL BARRETT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: KC ELLIS at 206-431-3677 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size I lxl7 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature; the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Cross reference details on sheet P3.10 with piping floor plan shown on sheet PLO. 2. Delete pool substrate details if not utilized per RFI. 3. Pool drains shall discharge into the Sanitary Sewer. Provide pool drain details and identify the airgap required between the drain and the sanitary sewer. PW - PG DEPARTMENT: Mike Cusick at 206-431-2441 if you have questions regarding these comments. The invert elevations for the points of connection for the 2 sanitary sewers and 3 roof drain leaders do not match the invert elevation shown sheets C4 of 8 and C5 of 8 dated September 2, 2005 by Barghausen Consulting Engineers. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resownittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, Rachelle Ripley Permit Technician File No. PG15-0127 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ARMIT COORQ COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0127 DATE: 11/10/15 PROJECT NAME: WASHINGTON PLACE - UNDERGROUND SITE ADDRESS: 223 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Yj "(/ [illy Building Division * Fire Prevention ❑ Public Works Structural ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator P DATE: 11/12/15 Structural Review Required ❑ DATE: DUE DATE: 12/10/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 Date: 11 I 1 0 15 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi]aWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan ChecWPermit Number: � � I S D L )- � ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Addre; Contact Person: M t—k & (Wcl Phone Number: a b( -?) �> 33 Summary of Revision: 0ffV09TUKfflLA =�. . Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision c Received at the City of Tukwila Permit Center by: P— Entered in TRAKiT on ( H 0 "( S- PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG15-0127 DATE: 10/30/15 PROJECT NAME: WASHINGTON PLACE - UNDERGROUND SITE ADDRESS: 223 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: yj OW lqI Building Division Fire Prevention ❑ Planning Division ❑ MG MYV, 111� Public Works Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 11/03/15 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 12/01/15 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Perinit Center Use Only CORRECTION LETTER MAILED: V II Departments issued corrections: Bldg Fire ❑ Ping ❑ PW �f Staff Initials: 12/18/2013 APOLLO SHEET METAL INC Page 1 of 6 home lnicio e n .ESpafiol Contact Safety Claims & Insurance Washington State Department of k Labor & Industries APOLLO SHEET METAL INC Owner or tradesperson PO BOX 7287 KENNEWICK, WA 99336 Principals 509-586-1104 RATCHFORD,BRUCE W BENTON County CRAWFORD,JAN VANSCHOIACK, JESSE, SECRETARY HAISCH, ANGIE, TREASURER VANSCHOIACK, JESSE, AGENT Doing business as APOLLO SHEET METAL INC WA UBI No. Business type 600 443 607 Corporation Governing persons ANGIE Search L&i i_r» A-L Index Help My Secure L&I Workplace Rights Trades & Licensing HAISCH BOB HIGHTOWER; BRUCE WAYNE RATCHFORD; DAN BRISCOE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. APOLLSM187MK Effective — expiration 07/12/1982— 04/09/2016 Bond ................ Western Surety Co $12,000.00 Bond account no. 58722918 Received by L&I Effective date 03/03/2015 04/09/2015 Expiration date Until Canceled Bond history Insurance .... _ .................. _.. . Cincinnati Ins Co $1,000,000.00 Policy no. EPP0044685 Received by L&I Effective date �� 09/25/2015 09/30/2011 v v https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=600443607&LIC=APOLLSM187MK&SAW= 11/20/2015 PIPING I L TIO E UL. INSULATION PIPE SIZE _j SYSTEM INSULATION NOTES TYPE (°) THICKNESS (") UP TO 1 '/ DOMESTIC AND NON -POTABLE COLD GLASS FIBER 1,2 GREATER THAN 1 1 WATER (ABOVE GROUND) DOMESTIC AND NON -POTABLE HOT UP TO 2 1 WATER AND HOT WATER RE-CIRC GLASS FIBER 1,2 (ABOVE GROUND) GREATER THAN 2 1'/z UPTO2 1 DOMESTIC AND NON -POTABLE HOT CELLULAR FOAM 1, 2 GREATER THAN 2 1'h WATER (BELOW GROUND) DOMESTIC AND NON -POTABLE COLD CELLULAR FOAM UP TO 8 '/ 2 WATER (BELOW GROUND) UP TO 2% 3 ENGINE EXHAUST (EMERGENCY HYDROUS CALCIUM 2 3 TO 6 4 GENERATOR) SILICATE 8T018 5 ROOF AND OVERFLOW DRAIN PIPING GLASS FIBER ALL 1 2 AND ROOF DRAIN SUMPS NOTES: 1. RUNOUTS UP TO 2" TO FIXTURES WHICH ARE LESS THAN 12 FEET IN LENGTH MAY HAVE 1/2 INCH INSULATION. 2. WHERE SCHEDULE EXCEEDS WASHINGTON STATE ENERGY CODE REQUIREMENTS, CODE MINIMUM IS ACCEPTABLE FOR USE. MAXIMUMLOADING BY BUILDING DRAIN COPYRIGHT © 2006-2008, PROVENT SYSTEMS INC., ALL RIGHTS RESERVED SLOPE 2% (1/4" PER FOOT) SLOPE 1% (1/8" PER FOOT) DRAIN SIZE FIXTURE UNITS FIXTURE UNITS 3" 42 36 4" 216 180 5" 350 280 6" 850 680 8" 2700 2160 10" 3900 3120 12" 5800 4640 MAXIMUM LOADING SST COPYRIGHT © 2006-2008, PROVENT SYSTEMS INC., ALL RIGHTS RESERVED STACK SIZE FIXTURE UNITS 3" 64 3" (OVER 7 STORIES) 102 4" 504 5" 1010 6" 2200 8" 3900 MAXIMUM LOADING BY BRANCH COPYRIGHT © 2006-2008, PROVENT SYSTEMS INC., ALL RIGHTS RESERVED I SLOPE 2% (1/4" PER FOOT) SLOPE 1% (1/8" PER FOOT) DRAIN SIZE FIXTURE UNITS FIXTURE UNITS 2" 6 5 I 3„ i 16 13 4" 90 72 0 DRAIN G FIXTRURE UNIT EQUIV ELANTS COPYRIGHT© 2006-2008, PROVENT SYSTEMS INC., ALL RIGHTS RESERVED FIXTURE FIXTURE UNITS BATHROOMS WATER CLOSET: FLUSH VALVLE 6 WATER CLOSET: TANK OPERATED 4 URINAL: PEDESTAL I 6 URINAL: NON -PEDESTAL 2 BIDET 2 BATHTUB (WITH OR W/O SHOWER) 2 SHOWER (PER SHOWERHEAD) 2 LAVATORY 1 BATHROOM GROUP 1: LAVATORY, BATHTUB (WITH OR W/O SHOWER), FLUSH VALVE WATER CLOSET 8 BATHROOM GROUP 1: LAVATORY, BATHTUB (WITH OR W/O SHOWER), TANK OPERATED WATER CLOSET 5 KITCHENS SINK (WITH OR W/O WASTE DISPOSAL) 2 SINK (SCULLERY) 2 DISHWASHER 2 LAUNDRY ROOM WASHING MACHINE 3 LAUNDRY TRAY (ONE OR TWO COMPARTMENTS) 2 SPECIALTY FIXTURES SINK: FLUSHING RIM WITH VALVES 6 SINK: SERVICE (P-TRAP) i 2 SINK: SERVICE (STANDARD TRAP) 3 I LAVATORY: SURGEON 2 LAVATORY: HAIRDRESSER, BEAUTY PARLOR 2 MISCELLANEOUS FLOOR DRAIN: 2" 2 DRINKING FOUNTAIN 1 G ESE TE SEE TOR TAG MANUFACTURER MODEL # SIZE (GALLONS) INLET/OUTLET SIZE NOTES GW-1 OLDCASTLE 5106-GA-1500 1500 6" 1 NOTES: 1. PROVIDE WITH H-20 WHEEL LOADING CAPABILITIES lur r 1� E ffi r ""Its i n= PLUMBING UNDERGROUND PERMIT SHEET LIST UG-P0.1 SCHEDULES - PLUMBING UG-P1.0 FOUNDATION PLAN - PLUMBING UG-P2.10 ENLARGED PLANS - PLUMBING UG-P3.10 DETAILS - PLUMBING UG-P4.20 PIPING DIAGRAM - PLUMBING UG-P4.21 PIPING DIAGRAM - PLUMBING UG-P4.22 PIPING DIAGRAM - PLUMBING UG-P4.23 PIPING DIAGRAM - PLUMBING UG-P4.24 PIPING DIAGRAM - PLUMBING UG-P4.25 PIPING DIAGRAM - PLUMBING UG-P4.26 PIPING DIAGRAM - PLUMBING UG-P4.27 PIPING DIAGRAM - PLUMBING UG-P4.28 PIPING DIAGRAM - PLUMBING UG-P4.29 PIPING DIAGRAM - PLUMBING UG-P4.40 PIPING DIAGRAM - PLUMBING 1. THIS WASTE SYSTEM IS AN ENGINEERED WASTE SYSTEM IN COMPLIANCE WITH CHAPTER 7 OF THE 2012 UPC. FOLLOW PROVENT MANUFACTURERS INSTRUCTIONS FOR THE INSTALLATION OF THE WASTE SYSTEM. A REQUEST FOR APPROVAL OF ALTERNATE MATERIALS AND METHODS WILL BE SUBMITTED FOR THE ABOVE GRADE PERMIT. 2. SIZING FOR ALL WASTE AND VENT PIPING IS REFERENCED IN THE WASTE AND VENT PIPING DIAGRAM. REFER TO P4 SERIES SHEETS FOR PIPE BRANCH AND RISER SIZING, AND FOR PROVENT FITTING LOCATIONS. 3. WASTE RISER DRAINAGE FIXTURE UNIT CALCULATIONS ARE PROVIDED AT THE BOTTOM OF EACH RISER DIAGRAM SHEET. THESE ARE THE SUM OF FIXTURE UNITS SHOWN ON THAT SHEET. THE NUMBER INDICATED AS "DFU" REFERS TO DRAINAGE FIXTURE UNITS AS CALCULATED BY CHAPTER 7 OF THE 2012 UPC. THE NUMBER INDICATED AS "PROVENT +" REFERS TO HOW MANY DRAINAGE FIXTURE UNITS ARE ADDED TO THE UPC CALCULATION TO BE IN COMPLIANCE WITH PROVENT MANUFACTURER'S REQUIREMENTS. 4. ON RISER DIAGRAM SHEETS SHOWING THE BASE OF A WASTE RISER, A SECOND SET OF NUMBERS ARE INCLUDED AT THE BOTTOM OF THE SHEET. THESE NUMBERS INDICATE THE ACCUMULATIVE DRAINAGE FIXTURE UNIT CALCULATION FOR EACH RISER. THE NUMBER INDICATED AS "DFU" REFERS TO DRAINAGE FIXTURE UNITS AS CALCULATED BY CHAPTER 7 OF THE 2012 UPC. THE NUMBER INDICATED AS "PROVENT +" REFERS TO HOW MANY DRAINAGE FIXTURE UNITS ARE ADDED TO THE UPC CALCULATION TO BE COMPLIANCE WITH PROVENT MANUFACTUER'S REQUIREMENTS. 5. ALL UNDERGROUND PIPING WILL BE A TRADITIONAL CAST IRON WASTE AND VENT SYSTEM AND WILL COMPLY WITH SIZING AND METHODS SET FORTH BY CHAPTER 7 OF THE 2012 UPC. C7Pefl ft" V7� 1 01 Plan review approval is subject to errors and omissions. Approval Of construction documents does not authorize the violation of any adopted code or ordinance. Receipt Of approved FieldnonditionsBy: Date:Z� is City of Tukwrila BUILDING DIVISION -RIECEIV - - NOV 13 2[ of work v thout pr or c ; p,-i0V0 b PUB Tuk rnta Buildi o NOTE* Revisions will rFquilro S � �.7 `cn v t3iliC}i'CSI wid may mdude addition 1 Flan mwsw tom`' RECEIVED CITY OF TUKWILA CO1 E TION NOV 10 2015 LTR# PERMIT CENTER ti • Date: 10/30/2015 Job No: 1430 Drawn By: EB Checked By: ESB Revision Schedule # Description Date 1 UG PERMIT 11/10/15 REVIEW REV1E1,.A1ED FOR CODE ::0-,MP LANCE ' I t r"f I wKwl la BUILDING DIVISION SCHEDULES - PLUMBING UG-PO-1 UNDERGROUND PERMIT GENERAL NOTES: 1. SYSTEMS SHOWN ARE DIAGRAMMATIC AND DO NOT INCLUDE ALL OFFSETS, FITTINGS, AND REQUIRED ROUTING. CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF COMPLETE AND OPERATIONAL SYSTEM WITH COMPLIANCE TO ALL APPLICABLE CODES AND AUTHORITY HAVING JURISDICTION. 2. ALL WORK SHALL BE CONCEALED AND NOT EXPOSED IN ANY FINISHED ROOM. 3. COORDINATE PIPE ROUTING WITH DUCTWORK, SPRINKLER PIPING, AND ELECTRICAL POWER/LIGHTING CIRCUITING AND STRUCTURAL MEMBERS PRIOR TO INSTALLATION. 4. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION OF PLUMBING FIXTURES, FLOOR D ALL HORIZONTAL WASTE PIPING 3" AND LESS IN SIZE SHALL BE SLOPED AT 2% GRADE, UNLESS OTHERWISE NOTED.— I 6. ALL HORIZONTAL WASTE PIPING 4" AND GREATER IN SIZE SHALL BE SLOPED AT 1% GRADE, UNLESS OTHERWISE NOTED. I ALL NEW PIPING ROUTING DOWN EXTERIOR WALLS TO SERVE NEW PLUMBING FIXTURES SHALL BE ON THE INTERIOR SIDE OF THE WALL INSULATION. 8. ALL DOMESTIC WATER PIPING IN UNCONDITIONED SPACES SHALL HAVE HEAT TRACE UNDERNEATH INSULATION. COORDINATE ELECTRICAL CONNECTIONS WITH DIVISION 26. ! WASTE SYSTEM IS AN ENGINEERED WASTE SYSTEM IN COMPLIANCE WITH CHAPTER 7 OF THE 2012 UPC. FOLLOW PROVENT MANUFACTURERS INSTRUCTIONS FOR THE INSTALLATION F E E ST 0. SIZING FOR ALL WASTE AND VENT PIPING IS REFERENCED IN THE WASTE AND VENT PIPING DIAGRAM. REFER TO UG-P4 SERIES SHEETS FOR PIPE BRANCH AND RISER SIZING, AND FOR PROVENT FITTING LOCATIONS. SIZING FOR RAIN LEADERS AND OVERFLOW PIPING IS REFERENCED IN THE RAIN LEADER RISER DIAGRAM. REFER TO SHEET UG-P4.40 FOR PIPE SIZING. 1 ALL RISERS FOR ROOF AND OVERFLOW DRAINS SHALL HAVE A CLEANOUT WHEN PIPE ! TRANSITIONS FROM VERTICAL TO HORIZONTAL. I I.d 3. REFERENCE DETAIL 1/UG-P3.10 FOR CLEANOUT TO FLOOR (COTF) AND CLEANOUT TO GRADE i (COTG) DETAILS. 1 REFERENCE DETAIL 2/UG-P3.10 FOR FLOOR DRAIN INSTALLATION DETAILS. d 5. REFERENCE DETAIL 3/UG-P3.10 FOR HUB DRAIN INSTALLATION DETAILS. s: f f IN f {[ z I } k { f I I� i i f � f } G/ T( 26.56 6" W SEE CIVIL FOR (, , ', .......... 4" COTG.... 4" COTG ........ "COTF CONTINUATION. " GW " GW 1IL TO TRANSITION T INVERTS LISTED. SEE CIVIL DRAWINGS FOR GW CO RDINATION 1 Jul 11 1 II 2" W UP WITH P-TRAP AND ; h PRIMER II 2" COTF II II 4'1 GW 3"VUP 2" W I> ........... I� �2" V I II II 2" W UP WITH P II II TRAP AND PRIMER > �V—V= II 2" V 2"WUP 2"VUP 4"WUP 2"VUP V_A" CO 411"W 211 W� 4"W UP TO HUB DRAIN FOR POOL SYSTEM DISCHARGE. 2" W UP WITH P TRAP AND PRIMER LIIY l7/1IV117L � 1 V I IICRJ. 1 f 1 FOUNDATION PLAN - PLUMBING 1 /8" - 1'-0" 2" W UP WITH P-TRAP AND PRIMER 2" COTF 2 COTF 2" W UP WITH P-TRAP AND PRIMER 2" V-/' '-211 W 2" W UP- 2"V UP TO I i \-3" V UP 2" V 12" AFF — _V— i 2" W ' 2" W- 2" V 2" V- (2) 2"VUP TO (1) 2" V ±12"AFF �A E 2" W- \ 211 II \-8"WUP II W sI W 2"V 4"WUP ss 4, �' 3 II ,1W I 2" W UP WITH P-TRAP , ; II ; € 2" W UP WITH P- RAP f ) I> AND PRIMER . AND PR ER I I. W II �_ S I 11 J 'I 11 W II II _ — ` 16 — —v= 2� v n II (2) 2" v UP To ` 1 1 II II (1) 2" V 12" AFF P a.. v 2" W UP WITH - RAP II II •�.,- .��.��-.�...•��,--w--.�.W 5" RDL UP AND P ER 21' V (2) 2" V UP " V ; 811 W TO(1)2"V ± 12" AFF 8"WUP /—loll W 0" W 10" COTI 5" RDL WASTE AND VENT NOTES: 1. DRAINAGE FIXTURE UNITS (DFU) ARE BASED ON REQUIREMENTS SET BY THE 2012 UPC CHAPTER 7, SANITARY DRAINAGE. FIXTURE UNIT EQUIVALENTS ARE BASED ON TABLE 702.1 AND 703.3 SIZING PER APPENDIX C, TABLE C 303.1(2). 2. PROVENT DRAINAGE FIXTURE UNITS ARE BASED ON REQUIREMENTS SET BY THE MANUFACTURER. SEE PROVENT DRAINAGE EQUIVALENTTABLES ON SHEET P0.3. T2 INVERT ELEVATION IE:26.88' — 6" RDL STUBBED OUT 5'-0" FROM BUILDING SEE CIVIL FOR CONTINUATION. CIVIL TO TRANSITION TO INVERTS LISTED. SEE CIVIL DRAWINGS FOR COORDINATION. A T 10" COTG 10" W STUBBED OUT 5'-0" FROM BUILDING SEE CIVIL FOR CONTINUATION. INVERT ELEVATION I E: 24.80' CIVIL TO TRANSITION INVERTS LISTED. SEE CIVIL DRAWINGS FOR COORDINATION. i i .t `5" RDL STUBBED OUT 5'-0" FROM BUILDING SEE CIVIL FOR.CONTINUATM. INVERT ELEVATION IE. 26.64' CIVIL TO TRANSITION TO INVERTS LISTED. SEE CIVIL DRAWINGS FOR COORDINATION. RECEIVED CITY OF TUKWILA NOV 1-0 2015 PERMIT CENTER PROJECT NORTH NDERGROUND PERMIT Mv Date: 10/30/2015 Job No: 1430 Drawn By: MT Checked By: ESB Revision Schedule # Description Date 1 UG PERMIT 11/10/15 REVIEW CODE ., City c3 Tukwila FOUNDATION PLAN - PLUMBING 2" GW UP WITH P-TRAP AND PRIMER Q�4" GW/ SEE UG-P/1.0 FOR CONTINUA 2" W A� 4" W SEE UG-P1.0 FOR CONTINUA GENERAL NOTES: 1. SYSTEMS SHOWN ARE DIAGRAMMATIC AND DO NOT INCLUDE ALL OFFSETS, FITTINGS, AND REQUIRED ROUTING. CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF COMPLETE AND OPERATIONAL SYSTEM WITH COMPLIANCE TO ALL APPLICABLE CODES AND AUTHORITY HAVING JURISDICTION. 2. ALL WORK SHALL BE CONCEALED AND NOT EXPOSED IN ANY FINISHED ROOM. 3. COORDINATE PIPE ROUTING WITH DUCTWORK, SPRINKLER PIPING, AND ELECTRICAL POWER/LIGHTING CIRCUITING AND STRUCTURAL MEMBERS PRIOR TO INSTALLATION. 4. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION OF PLUMBING FIXTURES, FLOOR DRAINS, ETC. 5. ALL HORIZONTAL WASTE PIPING 3" AND LESS IN SIZE SHALL BE SLOPED AT 2% GRADE, UNLESS OTHERWISE NOTED. 6. ALL HORIZONTAL WASTE PIPING 4" AND GREATER IN SIZE SHALL BE SLOPED AT 1% GRADE, UNLESS OTHERWISE NOTED. 7. ALL NEW PIPING ROUTING DOWN EXTERIOR WALLS TO SERVE NEW PLUMBING FIXTURES SHALL BE ON THE INTERIOR SIDE OF THE WALL INSULATION. 8. ALL DOMESTIC WATER PIPING IN UNCONDITIONED SPACES SHALL HAVE HEAT TRACE UNDERNEATH INSULATION. COORDINATE ELECTRICAL CONNECTIONS WITH DIVISION 26. 9. WASTE SYSTEM IS AN ENGINEERED WASTE SYSTEM IN COMPLIANCE WITH CHAPTER 7 OF THE 2012 UPC. FOLLOW PROVENT MANUFACTURERS INSTRUCTIONS FOR THE INSTALLATION W T 10. SIZING FOR ALL WASTE AND VENT PIPING IS REFERENCED IN THE WASTE AND VENT PIPING DIAGRAM. REFER TO UG-P4 SERIES SHEETS FOR PIPE BRANCH AND RISER SIZING, AND FOR PROVENT FITTING LOCATIONS. 11. SIZING FOR RAIN LEADERS AND OVERFLOW PIPING IS REFERENCED IN THE RAIN LEADER RISER DIAGRAM. REFER TO SHEET UG-P4.40 FOR PIPE SIZING. 12. ALL RISERS FOR ROOF AND OVERFLOW DRAINS SHALL HAVE A CLEANOUT WHEN PIPE TRANSITIONS FROM VERTICAL TO HORIZONTAL. 13. REFERENCE DETAIL 1/UG-P3.10 FOR CLEANOUT TO FLOOR (COTF) AND CLEANOUT TO GRADE (COTG) DETAILS. 14. REFERENCE DETAIL 2/UG-P3.10 FOR FLOOR DRAIN INSTALLATION DETAILS. 15. REFERENCE DETAIL 3/UG-P3.10 FOR HUB DRAIN INSTALLATION DETAILS. Q A A A A A A A I j� s s } 2" GW UP WITH P-TRAP AND PRIMER 2"GVUP 2"GVUP) 2 2 "GVUP 2" GV " 1�GV 2" GV I 4 GW " GW �G 2" W „ GW 4" GW UP WITH PAND � PRIMER 2" GV UP TO (1) 2" GV @ t 18" AFF 4" GW- 2" GW 3" COTF 3" GW 2" GW 3" GW 2" GV 2" GW UP WITH P-TRAP AND PRIMER 3" GW UP WITH P-TRA AND NO PRIMER 2" GV UP TO (1) 2" GV @ t 18" AFF SEE UG-P1.0 FOR CONTINUA 2"GVU :2" GV T "GW /-4" GW " COTF 2"WU 2"W 2"WUP 2"VUP 2" GW UP 2„ GW UP 2„V 2" GW UP 2"VUP _ 2"V � 2"VUP 2"GV _ 2" GV UP - - 2" GW 2" GV 2"WUP 2"GWUP 2" COTF ._............ .................... .......... _2" 1/V.__. _. �-2" GW 4" GW-J ;L i �%-2" GV 2" GV- 4" GW- 2"VU 2"V- 2"WUP ` aNd 2" W UP-/ 2" 1 '--4" COTF GV GV `2" GW UP WITH P-TRAP AND PRIMER 4" GW UP WITH P-TRAP AND PRIMER WUP W 2" GW UP WITH P-TRAP AND PRIMER W SEE UG-P1.0 FOR CONTINUATION)Q A A . A 1 ENLARGED PLAN - TI KITCHEN FOUNDATION - PLUMBING 1 1 /4" = V-0" RECEIVED CITY OF TUKWILA NOV 10 2065 PERMIT CENTER ru Date: 10/30/2015 Job No: 1430 Drawn By: EB Checked By: ESB Revision Schedule # Description Date 1 UG PERMIT REVIEW 11/10/15 REVIEMD ECR -'CODE COMPLIANCE PPRO TD NOV 1 9 2Q l CAt''Y -of TaaI�WiI BUILDING DIVISION ENLARGED PLANS - PLUMBING UG-P2.1 0 C HUB DRAIN INSTALLATION DETAIL NOT TO SCALE ;EIVED TUKWILA 1-0 2r5 ru-nrvu I' CEIvTER ® l•-i L. U Q a • • a C FD Z W v) Date: 10/30/2015 Job No: 1430 Drawn By: EB Checked By: ESB Revision Schedule # Description Date 1 UG PERMIT 11/10/15 REVIEW REVIEWED FOR CODE COMPLIANCE PPROVED 1,,0V 19 2015 CitY of Tukwila BUILDING DIVIRI DETAILS - PLUMBING UG-P3.1 0 5" VTR 3" VTR-)��T' VTR " VTR 5" VTR 4" VTR 4" VTR 4" VTR 4" VTR 5" VTR 6" VTR-\ �3" VTR �4" VTR KEYNOTES ROOF--- -f—- - - - - -- ---1 - I--- - I 1----—-- - - ---- --I - — - - - —I------ PROVENT AERATOR T I P8 P6 P6 P7 P7 1 I 1 O CONNECTIONS TO BE FITTING. INE SIZE. I� 1 1 I 4° V I L A � � I I I 1 INSTALL ACCORDING TO 1 z 4 V / 1 5' V 4 1 P7 P7 4 4 1 5" V i A 2 z z z 2 1 1 2"FD-1 4" V ( I 2 w 4 V I 1 1 1 4" V I P2 I P2 � 1�2" HUB DRAIN 4" V � P2 P2 2"FD-1 P3 P4 2"FD-1 2"FD-1 4" V I MANUFACTURERS 1 I 1 1 1 INSTRUCTIONS. _I___________ 1 I _g --� - -- -- - 1 --- --- 1 � - ---------1---- - -- - --- 1 1 2 PROVENT DEAERATOR FITTING. LOUNGE- - - - - � 1 " V I 1 I P8 I � � CONNECTIONS TO BE LINE SIZE. I INSTALL ACCORDING TO I I 5 V I 4"V I 1 MANUFACTURERS 6' V O I " V 5" V 1 1 I 1Q I 1 1� 4" W 1Zj5 5" VINSTRUCTIONS. V 4" V 14"W3W2„W 3W2" W2" W4' v 4" v 4° v I „ W 4"w 4„ W v6 V I I 2' W 4" VTR 1 4 V 2" W 2" W ---5" V 4" V 3" W 2" WI V 4 V 1 3ONNECTIONF NSTALLTE 4 V _ - -- - - - - - - - - - - - - - - -- -� I 1 - 5' V I 4 V ACCORDING TO PROVENT 3" V 4" V 4" V L -MANUFACTURERS 4"V I 4"V I I I 4"W ------ --�—--------- _ _ _ _— -- INSTRUCTIONS. � =1 — —j — — — — — — — — — — -- ----- —------------ — — — ---1-- �-'- �' 1 1 1 F- - - - - - - - - - - - - - - - - - - - - - - 1 I I - - - - - I - - 1 - WASTE AND VENT NOTES: LEVELI -T - -- - - - - -4V ,- I I 1 DRAINAGE FIXTURE UNITS (DFU) - -1- 1--- I -- I I - i - I -- - - -- 1--- 1 1 4 V 20 ARE BASED ON REQUIREMENTS 1 - SET BY THE 2012 UPC CHAPTER 7, I " 4 V 4" V 4 V � 4„ V 4„ V 4' V 4" V 4 V 4 V 4 V SANITARY DRAINAGE. FIXTURE 1 I I 4" V 4" V 4" V 4" W 4" V f V 4" V 4" V 4" V 4" V 4" V 4" V UNIT EQUIVALENTS ARE BASED ON TABLE 702.1 AND 703.3 SIZING PER . 4" V 4" V APPENDIX C, TABLE C 303.1(2). 1 i 1 i i PROVENT DRAINAGE FIXTURE II UNITS ARE BASED ON REQUIREMENTS SET BY THE LEVELI7� -1 -- -- -- -- - -- I-�-- -- - - -- - —- - - -- -- - - - -- - - -- - - -- -- -- -- -- - - MANUFACTURER. SEE PROVENT I DRAINAGE EQUIVALENTTABLES ON 1 SHEET.P0.3. I�n �n� o� I �z �d �N Rz �d 1nl P -4" \N Rri -4" 1N PA -4" W R7 �4" W RR i I 1-4" W R10 �4" W R11 /-4" W R12 /-4" W R13 " W R14 r-4" W R15 /-4" W R16 1-4" W R17 i-4" W R18 4" W R19 �4" W R20 �4" W R21 �4" W R22 �4" W R23 4" W R24 3" W 5 �-4" W R26 4" W R27 ) LEVEL 161 I I LEVEL 15 1 I G-P4.2 LEVEL 141 LEVEL 1 LEVEL 12i LEVEL11-i I I I LEVEL 10-I I I I LEVEL 9—I I I I LEVEL 8-I I 1 I G-P4.2 I LEVEL 7-1 I LEVEL 6 -! I I I LEVEL 5 I I I LEVEL 4 I I LEVEL _ 1 , G-P4.2 LEVEL 2 L-2" --L V -- — --8- $_ 2" V-N 3" V i 4" HUB DRAIN 1 1 2"FD-1 1 FOR FIRE SPRINKLER LEVEL 1 2" COTF 1 I SYSTEM d 4" W R28- - - W - -I- - F- - t - - - - - I - - - --i - - -0 - - -0 V- t- - - 1- — — - — - — - — — - — — — — - - — — - — - - — - — - — - - - — - — - — — - - — - — - — -� - — - — - - — - — - — - - — - - — - — - — - — - — - �3" V F- — - — - — - - — - — - — — - - — - — - — I _ 2Q - 02 38 DFU 12- U O - - O I 4" W 4" W 4" W W 4" W 3" W 4" W 4" W 4" W 4" W 4' W 4 4" W 4" W 4" W W R25 3" W R29 "WR24 -- - - - - - - - - - - - - - - 1 1 I I 1 , G-P4.2 1 PROVEN PROVEN PROVEN 7p-R-bV-ffN-j PROVEN PROVEN PR-6VENJ PROVEN PROVEN PROVEN PROVEN +45 DFU +54 DFU +36 DFU +66 DFU +60 DFU +50 DFU +50 DFU +50 DFU +64 DFU +32 DFU +50 DFU I ' - - - - - I - - i146 DFU 'i138 DFU 154 DFU i165 DFU !150 DFU L110 DFU 110 DFU ',108 DFU i162 DFU 61 DFU ;116 DFU I - 1 --- --- - -- - PROVEN --- Q O 4W V8" "W O 8„W 20 8W 6W 6'W 6W 6W 41 +ODFU 12 20�6"W20 „W "W ws W 8"w 20 w 20 20 „W 20 , 24 DFU I 6" I -- - 6 w 4" W W - W-/ P8 P7 W P6 P6 - P7 I--=-T--��-1--I TTTT� _ 4 4 2 4 4 4 4 4 2 2 2 PROVEN PROVEN PROVEN +36 DFU i 311 V I " W 4 DFU P2 P1 1 2"FD-1 P1 P1 I P1 1 P1 1 P1 2"FD-1 P3 1 P4 +64 DFU +68 DFU- - - - - 4" COTF 248 DFU 124 FU 187 DFU �� 8" W-/ TO STORAGE --*"'I I 1 L� —� -- 1 - - - -- -- FOOD SERVICES - — -- �L- -� I— 1 g 1 g (- 1 Q 0 0 1= 8" W 2" V , 2" V 1 4" w -- 3" W RECEIVED 8" W 2" V 6" W - - - - - - - - - _ _ PROVEN -r - - - - - - - - - - - - - 4„ W 384 DFU +135 DFU CITY OF TUKWILA 6" W 2" V 4" W 1 1, T- 1 �2" V I P7 1 P6 1 P6 1 P6 1 P7 ( I �?`:° --�---- - ------�-8-------J� - - - - - __ a colw OCT ��, 1 I P7 1 P7 1 4 18 DFU 1- T T 66 DFU I 1 I I I 2" COIW 8 W I 4" " �T --F TTTT LAUNDRY - ? I ? 1 ? I P7 l 4 1 P7 1 4 1 KITCHEN 4" COI W i 4 a 4 4 4 YP2 1 4" HUB DRAIN IN STAIRWELL PERMIT CENTER 1 P5 I P5 I 4" HUB DRAIN 2"FD-1 2"FD-1 2"FD-1 P2 P2 P4 I P2 I P1 I I P1 I P1 1 P1 IN STAI RWELL � 17 _g1 1 g 982 DFU PROVEN - - - - - - - — _+422 DFU � � g 73 DFU IL 17 4" HUB DRAIN I UT 22 10" W TO CITY MAIN AT 1% SLOPE. SEE IN STAIRWELL I ?" CIVIL FOR ADDITIONAL INFORMATION. M 25 �i a� V) Date: 10/30/2015 Job No: 1430 Drawn By: DW Checked By: ESB Revision Schedule # I Description Date PERMIT 8/28/15 2 REVIEW COMMENTS REVIEIVVED FOR — CCDE COz PI_IA3``ICE PROVED [ilov 19 21015 City of Tukwila BUILDING DIVISION PIPING DIAGRAM - PLUMBING 6" OVERFLOW DRAIN FOR FIRE TANK 116 GPM 10" W-/ 8" W-j \-4" Vi \-2" WX 565 DFU "--4" W 10"WTO VILFORCITY MAIN IONALI SLOPE. SEE WASTE AND VENT PIPING DIAGRAM CIVIL FOR ADDITIONAL INFORMATION. 1 - -- r------- NOT TO SCALE PROVEN +702 DFU 1240 SFj 146U Sri ZbSU 5rl wy oror ivou orb 2"RD-1 2"OD-1 2"RD-1 2"OD-1 a?"RD-1 2"OD-1 2"RD-1 2"OD-1 2"RD-1 2"OD-1 2"RD-1 2"OD-1 ROOF- - - - - - - - - - — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2"RD-1 1V v' 'v 2"OD-1 2"RD-1 v 12"OD-1 mv ' \ `-3"ODL _ - 3"RDL 4"RDL 3"RDL / �4"ODL �3"RDL 3"ODL 4"ODL - ---- 3"ODL 3"ODL 600 SF 1110 S 3"RDL 1080 S 630 SF 420 SF 1280 S 5"RDL 200 SF 1142 5"RDL 4"RDL 680 SF 2"RD-1 2"OD-1 2"RD-1 2"OD-1 2"RD-1 2"OD-1 2"RD-1 2"OD-1 2"RD-1 2"OD-1 2"AD-1 2"RD-1 2"OD-1 2"AD-1 2"RD-1 2"OD-1 LOUNGE- - - T - - T- - - - - - - - _� �- - - - - - �� - -�- - - - - - - - - - - - - - - - - - - - - - - - - - - - \-4"ODL �3"RDL 4"RDL 3"ODL mop "RDL 2"RD-1 2"OD-1 \t3"RDL ��-4"RDL 3"RDL \-3"RDL 3."RDL `3"RDL 3"RDLJ / 4"RDL 3"KUL YF<UL " Sq —� 3"ODL 4"ODL 3"ODL 3 RDL \\t3"RDL 5"RDL 5"RDL 4"RDL 3"RDL 3"ODL 5" RDL — — — — — — — — — — — — — — —R — — — — — — — — — — — — — — — — — — — — — — — — LEVEL18- - - - - - - - - - - - - - - - - - - - - - - i RAIN LEADER NOTES: 1. COMBINED STORM DRAINAGE SYSTEM SIZED PER 2012 UPC 1101.11:2.2(B). 2. NUMBERS IN PARENTHESES INDICATE LEVEL 17- - - -COLLECTIVE SQUARE FOOTAGE OF AREA - - - - - - - - - - - - - DRAINED. 3. ALL RISERS FOR ROOF AND OVERFLOW DRAINS SHALL HAVE A CLEANOUT WHEN PIPE TRANSITIONS FROM VERTICAL TO HORIZONTAL. LEVEL 16- — - - - - — - — - - - - - - - — - - - - — - - - 4"RDL 3" RDL i LEVEL 15---- --—- - - - - -- - - - -- - I— — — — — — — — — — — — — — -- \-3"RDL �4"RDL 5"RDLJ LEVEL 14 - — - — - — - — - — - — - -—---- t- I--r- - - - - —- I------I---N� -- --- \-5"RDL \-5"RDL 0 1 - — - - - - - - - -i - - - - - a- - - - - - - - - - LEVEL 13- — - — - — - — - — - — - — - — - — - — - — - - — - — - — - — — — — — — -- - — — — — — — — — — ---I — — — — — — — — — — — t N LEVEL 12-----------------1-1--1-----------I-------T--- - LEVEL 11- - - — - - - — - - - — - - - - - - - - — - - - - - - - - - - - - - - - - LEVEL 9- - — - — - - - - - - - - — - — - - 4---1 - -t-- - — - - - - I- - — - - - - --r - - - - - /_ - - LEVEL 8 - - — - - - — - - - - — - — - - - - [I - -t- - — - - - — - LEVEL 7- - - - - - - — - - - — - - - — 4"F LEVEL6 - — - — - — - — - — - — - — - — - — - — - — - - LEVEL 5- - - - — - — - - — - - - - - - LEVEL 4- — - - - - - — - - - - - - - Y LEVEL - — - - - — - — - - - - — - - - — - - - - - - - RDL "--4"RDL 5"RDL- - - - - - - -�_-211�---------------------- --- -r- - - - - —- - - - J*-- — — — — — — — — — — — --- ------ - 11\ ---------- ------ ---------------------- �5"RDL \-5"RDL \ - — - — - — - — - — - - — - — - — - — - — - — - — - — - — - — - — — — — — — — — — — — — — I — — — — — — — — — — — — — — — — — — — N� — — — —1 — — — — -- r — — — — — — — — — — — — — — — — — — — — — --------I----'------------1-----a------------- - i18 00 S 2"OD-1 2"RD-1 — — — — — — — s — — — — — — L 34l 600 S F 2"OD-1 2"RD-1 (1080 SF) (5350 SF) 3"RDL -cry 3"RDL- 5"RDL 2"AD-1 a — - - — - - - - - — - - - - — - — - - - - - — - - - - - - - - - — - - - --(6430SF) — - - - �- - - - - - - - - - - - - - LEVEL 2- - 2"SD TO STORM SEWER. SEE CIVIL FOR CONTINUATION. (4910 SF) 6"RDL (7320 SF) \-- 3"RDL-/ \-4"RDL `6"RDL 3"RDL—/ RECEIVED (630 SF) (1700 SF) (8130 SF) CITY OF TUKWILA 8" CO--\ OCT3020i5 "RDL -- -- - (s76o- - - - - - - - - -- -- - - -- - - - - - - - - - - -- - - - - -- - -- - - - PERMIT CENTER SP 4"RDL 1 (2950 SF) (46 OLSF) 5"RDL TO STORM SEWER. SEE 76 OLSF) "RDL TO STORM SEWER. SEE CIVIL FOR CONTINUATION. ( CIVIL FOR CONTINUATION. GROUND PERMIT 4"SD TO POOL SUBSTRATE DRAIN. 8"RDL 8"RDL TO STORM SEWER. SEE (11710 SF) CIVIL FOR CONTINUATION. 1 RAIN LEADER PIPING DIAGRAM NOT TO SCALE EXPIRES 2C / 7 Date: 10/30/2015 Job No: 1430 Drawn By: BA Checked By: ESB Revision Schedule # I Description Date i r� REV . ° D �'F.14' ,,� �5 Cr�a rF`�..4 :.r �,Y y ri o� u City Of Tukwila BUILDING DIVISION PIPING DIAGRAM PLUMBING UG-P4.4(