HomeMy WebLinkAboutPermit M15-0010 - ULTA BEAUTY - RTU AND CURB WORKULTA BEAUTY
17320 SOUTHCENTER PKWY
M15-0010
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
2623049110 Permit Number:
17320 SOUTHCENTER PKWY
Project Name: ULTA BEAUTY
Issue Date:
Permit Expires On:
M 15-0010
3/9/2015
9/5/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
KIR TUKWILA 050 LLC
3333 NEW HYDE PARK RD #100 PO
C/O KIMCO REALTY CORP, NEW HYDE
PK, IL, 11042
TIM KUHN
5100 RIVER RD - SUITE 125 , SCHILLER
PARK, IL, 60176
THREE RIVERS CONST & DEV INC
155 DESIGN PLACE STE 101, SPARKS,
NV, 89441
THREERC891RZ
Phone: (847) 916-2745
Phone: (775) 825-5248
Expiration Date: 1/3/2016
DESCRIPTION OF WORK:
REPLACEMENT OF THE (4) EXISTING RTU'S WITH (4) NEW RTU'S AND ASSOCIATED STRUCTURAL CURB WORK.
Valuation of Work: $55,000.00
Type of Work: REPLACEMENT
Fuel type: GAS
Fees Collected: $927.82
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: HIGHLINE,TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2012
Date: %r
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: � `" Date:31
Print Name: • to iu\c
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: ***MECHANICAL PERMIT CONDITIONS***
10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
11: Manufacturers installation instructions shall be available on the job site at the time of inspection.
12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance
#2437)
14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings
shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the
power source of the air -moving equipment upon detection of smoke in the main return -air duct served by
such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall
be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1)
15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437)
16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City
Ordinance #2437)
17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437)
18: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400 FIRE FINAL
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
0702 SMOKE DETECTOR TEST
CITY OF TUKWIL
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
ML-ooio
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 17320 S Center Parkway Tukwila, WA 98188 Suite Number: n/a Floor: 1
Tenant Name:
ULTA Beauty Store#191
PROPERTY OWNER
Name: Kimco Realty (Matt Barker)
Address: 3535 Factoria Blvd SE, Suite 520
City: Bellevue State: WA Zip: 98006
CONTACT PERSON — person receiving all project
communication
Name: Tim Kuhn - RGLA Solutions, inc.
Address: 5100 River Rd, Suite 125
City: Schiller Park State: IL Zip: 60176
Phone: (847) 916-2745 Fax: (847) 671-4200
Email: tkuhn@rgla.com
New Tenant: ❑ Yes
MECHANICAL CONTRACTOR INFORMATION
Company Name: TBD
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 725,098 55;e9cc°'
Describe the scope of work in detail:
Replacement of the 4 existing RTU's with 4 new RTU's and associated structural curb work.
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric ❑
Gas J
Other:
H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
4
Unit Type
Qty
Air handling unit
>10,000 cfin
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/I ,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER AUTHORIZED AGENT:
Signature: Date: 01/29/2015
Print Name: Tim Kuhn
Mailing Address: 5100 River Rd, Suite 125
Day Telephone: (847) 916-2745
Schiller Park IL 60176
City State Zip
H:\Applications\Forms-Applications On Line\201 I ApplicationsVNechanical Permit Application Revised 8.9-11.docx
Revised: August 2011
bh
Page 2 of 2
Receipt Number
DESCRIPTIONS ACCOUNT QUANTITY I PAID
PermitTRAK $1,782.07
EL15-0093 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $768.60
ELECTRICAL $732.00
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$732.00
TECHNOLOGY FEE $36.60
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$36.60
M15-0010 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $749.39
MECHANICAL $713.70
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$681.20
TECHNOLOGY FEE $35.69
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$35.69
PG15-0007 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $264.08
PLUMBING $251.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$219.00
TECHNOLOGY FEE $12.58
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R4776
R000.322.900.04.00 0.00 $12.58
$1,782.07
Date Paid: Monday, March 09, 2015
Paid By: JAMES MCCALLTHREE RIVERS CONS
Pay Method: CREDIT CARD 01096G
Printed: Monday, March 09, 2015 2:41 PM 1 of 1
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT I QUANTITY I
Perm itTRAK
PAID
$4,637.16
D15-0022 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110
$4,212.85
DEVELOPMENT
$4,212.85
PLAN CHECK FEE R000.345.830.00.00
0.00
$4,212.85
EL15-0093 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110
$183.00
ELECTRICAL
$183.00
PLAN CHECK FEE R000.345.832.00.00
0.00
$183.00
M15-0010 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110
$178.43
MECHANICAL
$178.43
PLAN CHECK FEE R000.322.102.00.00
0.00
$178.43
PG15-0007 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110
$62.88
PLUMBING
$62.88
PLAN CHECK FEE R000.322.103.00.00
TOTAL FEES PAID BY RECEIPT: R4385
0.00
$62.88
$4,637.16
Date Paid: Friday, January 30, 2015
Paid By: ANDREW PAROLINE
Pay Method: CREDIT CARD 210340
Printed: Friday, January 30, 2015 9:59 AM 1 of 1
CWSYSTEMS
INSPECTION RECORD
Retain a copy with permit
i'M-CPO
INSP''!T� NO. PERMIT NO.
CITY OF TUKWILA BUILDING
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ti.tP� -21
Permit Inspection Request Line (206) 438-9350
Project:
0 L4 Av�f
Type of Inspection: ' /
# j' //Hjz
Address: '14 S0
/%a Z Si.
Date Called:
Special Instructions:
`')
Date Wanted:
7—Z. VC
a.m.
p.m.
Requester:
Phone No:
"77c4/5tI rl 5(1
Approved per applicable codes. O Corrections required prior to approval.
M M ENTS:
714 cov_e_
cou-ece-uo (oA
Kef iq �K+pfeyr
/f a
rtaer
AiLte_c-
Inspector:
Date - ,3 1 J
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
r
evt'iq eJtt 6lv, =L> /kw% . fir®v
1011.1 Retain a copy with permit
INSPECTION RECORD
ECTI N NO. PERMIT NO.
A/Ur-0qt°
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Prkkje\tk_: ,(y)k,‘,i_A\i
Type inspectr:
......" IN_
Address:
\7 ->U) 5(1\11/414j)k r 4171A1
D
Date ailed:
Special Instructions:
D te tt nted:
-
,1--
-)
a.m.
P.m.
'Requeec, A
If—V-'
Phone No:
Approved per applicable codes. El Corrections required prior to approval,
OMMENTS:
iq cue;it
Inspector:
Date: Lr
E
RE1NSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection
INSPECTION RECORD
Retain a copy with permit
IN ON NO. PERMIT NO.
M I5-00 10
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Projeit:
( fi 6e-fANA.f
Type of trig o :
0-0k
Address:
177 22 fo,cf-k Or l'r441,
Date Called:
Special Instructions: ,
itv/vi
Date Wanted:
a.m.
Requester:
Phone No:
DApproved per applicable codes. Corrections required prior to approval.
CO
MMENTS: fl/tAJE r-icA,
P74-- '<V(t ordrme,5
gsb
inspector:
F
Date: ti
0 (
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection.
F"
INSPECTION RECORD
Retain a copy with permit
NSP TION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
AtCr -00 (0
Irp
LLI
ec.r.
-111 /lest vo---
Type of flspection:
P( QU1/40- ''"tAl 1/L-1
fd:
Address:
173 2-0 rout-ft/Lc-fp
y
iff-4./V•
Date Cat
Special Instructions: Ai(
Date Wanted:
3 - 2-,-{
- (J-
a.m.
p.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval,
COMMENTS:
A flvx_.,T- -7(rfd:y X00
ac) Ot'71
)F.E....,, Inspec r:
F
••••••••••••*
DI- 2-9 fj
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
./0/5--- 00
Project:
(-{ itrt
'Type
of Inspe tion:
.gaLki-it
ddress:
1 7-40 fd LeflA Cii" 0-41
Date Cafe
Special Instructions: Ai
Pltafe = er-013-1f—
Date Wanted: a.m.
f_S— P.m.
Request
&,q we tf-03 1(1( t/evi-
Phone No•
3100030
IFirApproved per applicable codes.
COMMENTS:
EJCorrections required prior to approval.
/
(r
K.....C......, Inspector: '
ate:
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection,
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Mechanical Summary
MECH-SUM
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Revised June 2013
Project Info
Project Address ULTA #191 PARKWAY SUPERCENTER
Date 1/13/2015
17320 S. CENTER PARKWAY
For Building Dept. Use
PLIIANCE WITI-
PA ° 70 - NEC
TURWILA, WA 98188 REVIEWED��
Applicant Name: RGLA SOLUTIONS, INC j S
Applicant Address: 5100 RIVER RD, STE 125 SCHILLER PARK
T�VL,
Applicant Phone: 847-671-7452
Project Description
Briefly describe mechanical
system type and features.
Includes Plans
j�jj'UE COPY ^.1..
u +�
FEB 11 2015
(ILL
!r Hog
i ofTukwila
Drawings must contain notes requiring compliance with commissim
Fib i . vi ' ijiiW Fell k
ki
Compliance Option
[
( Simple System ( :Complex_SyStem s"v :-(- Systems Analysis
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on
the plans. For projects without plans, fill in the required information below.
Cooling Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
Capacity2
Btu/h
OSA CFM
or Econo?
SEER
or EER
IPLV3
Econmizer
Option or
Exceptions
Heat
Recovery
Y/N
RTU-1
DX
LENNOX •
LGH120H4B
124
ECONO
12.0 EER
N/A
ECONO
N
RTU-2
DX
LENNOX
LGH12OH4B
124
ECONO
12.0 EER
N/A
ECONO
N
RTU-3
DX
LENNOX
LGH12OH4B
124
ECONO
12.0 EER
N/A
ECONO
N
RTU-4
DX
LENNOX
LGH120H4B
124
ECONO
12.0 EER
N/A
ECONO
N
Heating Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
Capacity2
Btu/h
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency°
Heat
Recovery
Y/N
RTU-1
GAS
LENNOX
LGH120H4B
240
ECONO
240
192
80
N
RTU-2
GAS
LENNOX
LGH120H4B
240
ECONO
240
192
80
N
RTU-3
GAS
LENNOX
LGH120H4B
240
ECONO
240
192
80
N
RTU-4
GAS
LENNOX
LGH12OH4B
240
ECONO
240
192
80
N
Fan Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
CFM
Sp1
HP/BHP
Flow Controls
Location of Service
RTU-1
FAN
3850
1.00
3.00
CV
SUPPLY AIR BLOWER
RTU-2
FAN
4000
1.00
3.00
CV
SUPPLY AIR BLOWER
RTU-3
FAN
3825
1.00
3.00
Cv
SUPPLY AIR BLOWER
RTU-4
Service
Equip.
ID
EXIST
FAN
Water
Equip
Type
Heating Equipment
Brand Name'
Schedule
Model No.1
4070
Input
Capacity
1.00
Sub -
Category
3.00
EFL
CV
Location
SUPPLY AIR BLOWER
. v.
of Service
1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustin1'fipncIt,,olatfasA
applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Ecorai e e pti Err
M
soo(o
JAN 3 0 2015
PERMIT CENTER
Mechanical Permit Plans Checklist - Page 1 of 3
MECH-CHK
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Revised June 2013
Project Address ULTA#191 PARKWAY SUPERCENTER
Date 1/13/2015
The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012
WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages.
Applicability
(yes,no,na)Code
Section
Code Provision
Information Required
Location on
Plans
Building Department
Notes
GENERAL PROVISIONS
Equipment Sizing & Performance
YES
C403.2.1
Load calculations
Load calculations performed per ASHRAE Std 183 or equivalent per
Chapter 3
Replaced w/ same
YES
C403.2.2
Equipment and system
sizing
Output capacity of heating and cooling equipment and systems do not
exceed calculated loads, note exceptions taken
Replaced w/ same
YES
C403.2.5
Minimum ventilation
Ventilation (natural or mechanical) provided per IMC; indicate mechanical
ventilation is capable of being reduced to minimum requirement per IMC
M-3
YES
C403.2.3 &
C403.2.3.2 &
C403.2.12.1
Equipment minimum
efficiency
Provide equipment schedules or complete MECH-SUM tables with type,
capacity, efficiency, test standard (or other efficiency source) for all
mechanical equipment
M-3
YES
C403.2.13
Electric motor efficiency
Provide equipment schedule with hp, rpm, efficiency for all motors; note
except.
M 3
YES
C403.2.10
Fan power limitation
Fan system motor hp or bhp does not exceed limits per Table
C403.2.10.1(1)
M-3
N/A
C403.2.10.3
& C403.2.13
Fractional hp fan motors
Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency
req.
N/A
C403.2.3
Maximum air cooled chiller
capacity
Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit
N/A
C403.2.1
Non-standard water-cooled
chillers
Full -load and NPLV values for water-cooled centrifugal chiller adjusted for
non-standard operational conditions
N/A
C403.2.12.1.2
Centrifugal fan cooling
towers
Large capacity cooling towers with centrifugal fan(s) meet efficiency
requirements for axial fan open circuit cooling towers
N/A
C403.2.3
Forced air furnace and unit
heaters
Indicate intermittent ignition or IID, flue/draft damper & jacket loss
N A
/
C403.2.3.3
heating/cooling equipment Packaged electric
List equipment required to be heat pumps on schedule
N/A
C403.2.3.4
Humidification
Indicate method of humidification (note requirements for systems with
economizer)
HVAC System Controls & Criteria
YES
C403.2.4.1
Thermostatic controls
Indicate locations of thermostatic control zones on plans, including
perimeter systems
M-1, M-2
N/A
C403.2.4.1.1
Heat pump supplementary
heat
Indicate staged heating (compression/supplemental) & outdoor lock -out
temp
YES
C403.2.4.2
Setpoint overlap (deadband)
Indicate 5°F deadband minimum for systems controlling both heating &
cooling
M-4, M-5, EMS
YES
C403.2.4.3
Automatic setback and
shutdown
Indicate zone t-stat controls with required automatic setback & manual
override
M-4, M-5
YES
C403.2.4.3.3
Automatic (optimum) start
Indicate system controls that adjust equip start time to match load
conditions
M-3, M-4, M-5, EMS
YES
C402.4.5.2 &
C403.2.4.4
Dampers
Indicate location of OSA, exhaust, relief and return air dampers; include
AMCA rated leakage and control type (motorized or gravity; note exceptions
-
N/A
C403.2.11
Heating outside a building
Indicate radiant heat system and occupancy controls
N/A
C403.2.4.5
Snow melt systems
Indicate shut-off controls based on outdoor conditions
YES
C403.2.4.6
Combustion heating
equipment
Indicate modulating or staged control
M-3
N/A
C403.2.4.7
Group R1 hoteVmotel
systems
Indicate method for guest room automatic setback & set-up of 5°F minimum
N/A
C403.2.4.8 / g
Group R2/R3 dwelling unit
systems
Indicate 5-2 programmable thermostats in primary spaces with minimum of
two setback periods; note exceptions taken
N/A
C403.2.5.1
Demand controlled
ventilation
Indicate high -occupancy spaces and systems requiring DCV
N/A
C403.2.5.2
Occupancy sensors
Indicate spaces requiring occupancy -based system control and method; or
alternate means provided to automatically reduce OSA when partially
N/A
/
C403.2.5.3
Enclosed loading
dock/parking garage
ventilation
Indicate enclosed loading dock and enclosed parking garage ventilation
system activation and control method
N/A
C403.2.5.4.1
Kitchen exhaust hoods
Indicate kitchen hoods requiring make-up air; indicate make-up air source
and conditioning method
N/A
C403.2.5.4.2
Laboratory exhaust systems
Indicate lab exhaust systems requiring heat recovery, method & efficiency;
or alternative method taken (VAV, semi -conditioned makeup, or GERM
calculation)
N/A
C403.2.6.1
Energy recovery -
ventilation systems
Indicate ventilation systems requiring ER, method & efficiency; note
exceptions
NA
/
C403.2.6.2
Energy recovery -
condensate systems
Indicate on -site steam heating systems requiring energy recovery
NA
/
C403.2.6.3
Energy recovery -
condenser systems
• A
Indicate reorote refrig/Eondensers regwinhgR and Use of captured' ergy
Mechanical Permit Plans Checklist - Page 2 of 3
MECH-CHK
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Revised June
2013
Project Address ULTA #191 PARKWAY SUPERCENTER !Date 1/13/2015
The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012
WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages.
Applicability
(yes,no,na)
Code Section
Code Provision
Information Required
Location on
Plans
Building Department
Notes
GENERAL PROVISIONS, CONTINUED
HVAC System Controls & Criteria, Continued
N/A
C403.2.12
Variable flow control -
fans/pumps
Indicate fan & pump motors requiring VF control & method (VSD or equiv
controls)
N/A
VarC403.2.12.1 cooling t flow
we control
cooling towers
Indicate cooling tower fans requiring variable flow control and method
N/A
C403.2.12.2
Large volume fan systems
Indicate fan systems requiring airflow reduction based on heating and
cooling demand; or exception taken
N/A
C403.2.12.2
Single zone AC systems
Indicate method of cooling demand -based fan control for sys. > 110,000
btuh
N A
/
C403.2.4.10
DDC system capabilities
Identify all DDC system input/output control points and indicate capability
for trendino and demand response setpoint adiustment
Ducting Systems
YES
C403.2.7.1 &
C403.2.7.3
Duct construction
Indicate all ductwork constructed and sealed per IMC, C402 leakage
requirements and IBC vapor retarder requirements
M-4, M-5
YES
:::.403.2.7.3.1-:
Duct pressure classifications
Identify location of low, medium and high pressure ductwork on plans
M-4, M-5
N/A
C403.2.7.3.3
High pressure duct leakage
test
Indicate high pressure duct leakage testing requirements on plans; provide
test results to jurisdiction when completed
YES
C403.2.7.1 /2
Duct insulation
Indicate R-value of insulation on ductwork
M-1
Piping Systems
YES
C403.2.8
Piping insulation
Indicate R-value of insulation on piping
P-6, P-7
N/A
C403.2.8.1
Piping insulation exposed to
weather
Indicate method of protection from damage/degredation
SIMPLE SYSTEMS
Qualifying Systems
YES
C403.3
Qualifying single zone
systems
Verify unitary or packaged equipment does not exceed capacity limits, does
not have active humidifcation or simultaneous heatinq/cooling
M-3
N/A
C403.3
Qualifying 2-pipe heating
systems
Verify 2-pipe heating -only system does not exceed capacity limits
N/A
C403.3.2
Hydronic system controls
Refer to Complex Systems Section C403.4.3
Simple System Economizers
YES
C403.3.1
Air economizer required
Indicate cooling systems requiring economizer controls; note in equip
sched.
M-3
YES
C403.3.1.1.1
Air economizer capacity
Indicate modulating OSA control capability up to 100% OSA, or exception
M-3
YES
C403.3.1.1.3
Air economizer high limit
controls
Indicate high limit shut-off control method per Table C403.3.1.1.3(2)
M-3
YES
C403.1.1.2
Integrated air economizer
operation
Indicate capability for partial air economizer operation for systems with
capacity > 65,000 btuh
M-5
N/A
C403.3.1
Air economizer exceptions
Indicate eligible exception(s) taken and provisions to comply with
exceotion(s)
COMPLEX SYSTEMS
Complex System Economizers
N/A
C40341
..
Air economizer required
Indicate cooling systems requiring economizer controls; note in equip
sched.
N/A
C403.4.1.4
Economizer heating system
impact
Verify control method of HVAC systems with economizers does not
increase building heating energy usage during normal operation
N/A
C403.4.1.3
Integrated economizer
operation
Indicate capability for partial economizer operation for air or water econo
systems
N/A
Moved
Water economizer capacity
Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb
OSA
N/A
C403.4.1.2
Water economizer
maximum pressure drop
Indicate precooling coils and heat exchangers do not exceed pressure drop
limit
N/A
c403.3.1
Air economizer exceptions
Indicate.eligible exception(s) taken and provisions to comply with
eotion(s)
Mechanical Permit Plans Checklist - Page 3 of 3
2012 Washington State Energy Code Compliance Forms tor Commercial, Group R1, and> 3 story R2 and R3
MECH-CHK
Revised June 2013
Project Address ULTA #191 PARKWAY SUPERCENTER
Date 1/13/2015
The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012
WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages.
Applicability
(yes,no,na)
Code Section
Code Provision
Information Required
Location on
Plans
Building Department
Notes
COMPLEX SYSTEMS, CONTINUED
Specific System Requirements
N/AC403.2.12Variable
C403.4.2 &
flow control - fans
Indicate fans requiring variable flow control and method
N/A
C403.4.2.1
VAV fan static pressure
sensors
Indicate sensor locations on plans; include at least one sensor per major
duct branch
N/A
C403.4.2.2
VAV fan static pressure
setpoint
Indicate fan system static pressure setpoint based on zone requiring most
pressure
N/A
C403.4.5
VAV systems serving multi-
zones
Indicate supply air systems serving multiple zones that are required to be
VAV, method of primary air control, and zones served; note exceptions
taken
N/A
C403.4.5.4
VAV system supply air reset
Indicate controls that automatically reset supply air temp in response to
loads
N/A
C403.4
Large capacity cooling
systems
Indicate method of multi -stage or variable control for building cooling
system capacity > 300 tons
N/A
C403.4.7
Hot gas bypass limitation
Indicate cooling equipment unloading or capacity modulation method
N/A
C403.4.3
Large capacity boiler
systems
Indicate multi -stage or modulating burner for single boilers > 500,000 btuh
N/A
C403.4.3
Boiler sequencing
Indicate automatic controls that sequence operation of multiple boilers
N/A
C403.4.3.5
Chiller / boiler plant pump
isolation
Indicate capability to automatically reduce overall plant flow and shut-off
flow through chillers & boilers when not in use
N/A
C403.4.2 &
C403.4.3.6
Variable flow control -
pumps
Indicate pumps requiring variable flow control & method
/ A
CN
& C403.4.4
& C4.2.12.103.4.4
Varcooling towers flow
control -
cooling
Indicate cooling tower fans requiring variable flow control and method
N/A
C403.4.3.4
Hydronic system part load
controls
reset supply water temp AND reduce flow by a 50% for systems > 300,000
N/A
C403.4.3.2
Two -pipe changeover
systems
Indicate deadband, heating/cooling mode scheduling and changeover
temperature range
N/A
C403.4.3.3.1
Water loop heat pump -
deadband
Indicate capability of central equipment to provide min. 20°F water supply
temp deadband between heat rejection and heat addition modes
N/A
C403.4.3.3
Water loop heat pump -
heat rejection
Provide heat exchanger that separates cooling tower and heat pump loop in
Climate Zone 5
N/A
C403.4.3.3.3
Water loop heat pump -
isolation
Indicate 2-way isolation valve on each heat pump and variable flow control
for systems with total pump power > 10 hp
N/A
C403.4.6
recovery Condenser water heat
Indicate system provided to pre -heat service water and efficiency
N/A
C403.5
Cooler / freezer - anti -sweat
heaters
Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat
heaters
N/A
C403.5 / 6
Cooler / freezer -evaporator
and condenser fans
Indicate motor type for evaporator and condenser fans < 1 hp
SERVICE WATER HEATING
Service Water Systems
N/A
C404.2
Water -heating equip min.
efficiency
Provide equipment schedule or complete MECH-SUM table with type,
capacity, efficiency, test standard (or other efficiency source)
EXIST
N/A
C404.3
Temperature controls
Indicate temperature controls have required setpoint capability
EXIST
N/A
C404.4
Heat traps
Indicate piping connected to equipment have heat traps on supply &
discharge
N/A
C404.5
Insulation under water
heater
Indicate R-10 insulation under tank
EXIST
YES
C404.6
Service water piping
insulation
Indicate R-value of insulation on i n note exce tions taken
p p g' p
P-6, P-7
YES
C404.7 / 8
Circulation systems and
heat trace shut-off
Indicate shut-off capability based on occupancy and periods of limited
demand
EXIST
N/A
C404.9
Group R-2 service hot water
meters
Indicate method of usage metering for dwell. units served by central HW
system
Pools & In -Ground Permanently Installed Spas
N/A
C404.10.1
Pool heating equip min.
efficiency
Provide equipment schedule or complete MECH-SUM table with type,
capacity, efficiency, test standard (or other eff. source); heat pump heaters
a 4 COP
N/A
C404.10.1 / 2
Pool heater on /off controls
Indicate automatic on/off control based on scheduling & accessible on/off
switch on heater that operates independent of thermostat setting; or
N/A
C404.10.3
Pool covers
Indicate vapor retardant cover and insulation rating as required
N/A
C404.10.3
Pool assembly insulation
Indicate rating of insulation on sides and bottom of pools heated to > 90°F
N/A
C404.10.4
Heat recovery
Indicate method, exhaust air temperature reduction and recovered energy
use
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M15-0010
DATE: 01/30/15
PROJECT NAME: ULTA BEAUTY
SITE ADDRESS: 17320 SOUTHCENTER PKWY
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Al_kw/ 2r6-I'
Building Division IN
Public Works
Al4A }2-IO
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 02/03/15
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
n
n
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 03/03/15
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
THREE RIVERS CONST & DEV T'`TC
Home Inicio en .Espanol Contact
Page 1 of 2
Search L&I
A-Z Index Help Day Secure L&I
Safety Claims & Insurance Workplace Rights Trades & Licensing
Washington State Department of
Labor & Industries
THREE RIVERS CONST & DEV INC
Owner or tradesperson
VAN JR, ROBERT LYNN
Principals
VAN JR, ROBERT LYNN, PRESIDENT
VAN, MICHELLE LYNN, SECRETARY
Doing business as
THREE RIVERS CONST & DEV INC
WA UBI No.
603 158 536
155 Design Place Ste 101
SPARKS, NV 89441
775-825-5248
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
..........................................................................
Meets current requirements.
License specialties
GENERAL
License no.
THREERC891RZ
Effective — expiration
01/03/2012— 01/03/2016
Bond
................
Old Republic Surety Co
Bond account no.
W150111287
Received by L&I
12/05/2011
Insurance
State National Ins Co Inc
Policy no.
XNDP0105800
$12,000.00
Effective date
11/20/2011
Expiration date
Until Canceled
$1,000,000.00
Received by L&I Effective date
10/09/2014 10/05/2014
Expiration date
10/05/2015
Insurance history
Savings
..................
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
........................................
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603158536&LIC=THREERC891 RZ&SAW= 03/09/2015