Loading...
HomeMy WebLinkAboutPermit M15-0010 - ULTA BEAUTY - RTU AND CURB WORKULTA BEAUTY 17320 SOUTHCENTER PKWY M15-0010 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049110 Permit Number: 17320 SOUTHCENTER PKWY Project Name: ULTA BEAUTY Issue Date: Permit Expires On: M 15-0010 3/9/2015 9/5/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC 3333 NEW HYDE PARK RD #100 PO C/O KIMCO REALTY CORP, NEW HYDE PK, IL, 11042 TIM KUHN 5100 RIVER RD - SUITE 125 , SCHILLER PARK, IL, 60176 THREE RIVERS CONST & DEV INC 155 DESIGN PLACE STE 101, SPARKS, NV, 89441 THREERC891RZ Phone: (847) 916-2745 Phone: (775) 825-5248 Expiration Date: 1/3/2016 DESCRIPTION OF WORK: REPLACEMENT OF THE (4) EXISTING RTU'S WITH (4) NEW RTU'S AND ASSOCIATED STRUCTURAL CURB WORK. Valuation of Work: $55,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $927.82 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Date: %r I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: � `" Date:31 Print Name: • to iu\c This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Mechanical Permit No. Project No. ML-ooio Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 17320 S Center Parkway Tukwila, WA 98188 Suite Number: n/a Floor: 1 Tenant Name: ULTA Beauty Store#191 PROPERTY OWNER Name: Kimco Realty (Matt Barker) Address: 3535 Factoria Blvd SE, Suite 520 City: Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Tim Kuhn - RGLA Solutions, inc. Address: 5100 River Rd, Suite 125 City: Schiller Park State: IL Zip: 60176 Phone: (847) 916-2745 Fax: (847) 671-4200 Email: tkuhn@rgla.com New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 725,098 55;e9cc°' Describe the scope of work in detail: Replacement of the 4 existing RTU's with 4 new RTU's and associated structural curb work. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas J Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 4 Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/I ,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature: Date: 01/29/2015 Print Name: Tim Kuhn Mailing Address: 5100 River Rd, Suite 125 Day Telephone: (847) 916-2745 Schiller Park IL 60176 City State Zip H:\Applications\Forms-Applications On Line\201 I ApplicationsVNechanical Permit Application Revised 8.9-11.docx Revised: August 2011 bh Page 2 of 2 Receipt Number DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $1,782.07 EL15-0093 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $768.60 ELECTRICAL $732.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $732.00 TECHNOLOGY FEE $36.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $36.60 M15-0010 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $749.39 MECHANICAL $713.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $681.20 TECHNOLOGY FEE $35.69 TECHNOLOGY FEE R000.322.900.04.00 0.00 $35.69 PG15-0007 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $264.08 PLUMBING $251.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $219.00 TECHNOLOGY FEE $12.58 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4776 R000.322.900.04.00 0.00 $12.58 $1,782.07 Date Paid: Monday, March 09, 2015 Paid By: JAMES MCCALLTHREE RIVERS CONS Pay Method: CREDIT CARD 01096G Printed: Monday, March 09, 2015 2:41 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I Perm itTRAK PAID $4,637.16 D15-0022 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $4,212.85 DEVELOPMENT $4,212.85 PLAN CHECK FEE R000.345.830.00.00 0.00 $4,212.85 EL15-0093 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $183.00 ELECTRICAL $183.00 PLAN CHECK FEE R000.345.832.00.00 0.00 $183.00 M15-0010 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $178.43 MECHANICAL $178.43 PLAN CHECK FEE R000.322.102.00.00 0.00 $178.43 PG15-0007 Address: 17320 SOUTHCENTER PKWY Apn: 2623049110 $62.88 PLUMBING $62.88 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R4385 0.00 $62.88 $4,637.16 Date Paid: Friday, January 30, 2015 Paid By: ANDREW PAROLINE Pay Method: CREDIT CARD 210340 Printed: Friday, January 30, 2015 9:59 AM 1 of 1 CWSYSTEMS INSPECTION RECORD Retain a copy with permit i'M-CPO INSP''!T� NO. PERMIT NO. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ti.tP� -21 Permit Inspection Request Line (206) 438-9350 Project: 0 L4 Av�f Type of Inspection: ' / # j' //Hjz Address: '14 S0 /%a Z Si. Date Called: Special Instructions: `') Date Wanted: 7—Z. VC a.m. p.m. Requester: Phone No: "77c4/5tI rl 5(1 Approved per applicable codes. O Corrections required prior to approval. M M ENTS: 714 cov_e_ cou-ece-uo (oA Kef iq �K+pfeyr /f a rtaer AiLte_c- Inspector: Date - ,3 1 J REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r evt'iq eJtt 6lv, =L> /kw% . fir®v 1011.1 Retain a copy with permit INSPECTION RECORD ECTI N NO. PERMIT NO. A/Ur-0qt° CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prkkje\tk_: ,(y)k,‘,i_A\i Type inspectr: ......" IN_ Address: \7 ->U) 5(1\11/414j)k r 4171A1 D Date ailed: Special Instructions: D te tt nted: - ,1-- -) a.m. P.m. 'Requeec, A If—V-' Phone No: Approved per applicable codes. El Corrections required prior to approval, OMMENTS: iq cue;it Inspector: Date: Lr E RE1NSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permit IN ON NO. PERMIT NO. M I5-00 10 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projeit: ( fi 6e-fANA.f Type of trig o : 0-0k Address: 177 22 fo,cf-k Or l'r441, Date Called: Special Instructions: , itv/vi Date Wanted: a.m. Requester: Phone No: DApproved per applicable codes. Corrections required prior to approval. CO MMENTS: fl/tAJE r-icA, P74-- '<V(t ordrme,5 gsb inspector: F Date: ti 0 ( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. F" INSPECTION RECORD Retain a copy with permit NSP TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 AtCr -00 (0 Irp LLI ec.r. -111 /lest vo--- Type of flspection: P( QU1/40- ''"tAl 1/L-1 fd: Address: 173 2-0 rout-ft/Lc-fp y iff-4./V• Date Cat Special Instructions: Ai( Date Wanted: 3 - 2-,-{ - (J- a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval, COMMENTS: A flvx_.,T- -7(rfd:y X00 ac) Ot'71 )F.E....,, Inspec r: F ••••••••••••* DI- 2-9 fj REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ./0/5--- 00 Project: (-{ itrt 'Type of Inspe tion: .gaLki-it ddress: 1 7-40 fd LeflA Cii" 0-41 Date Cafe Special Instructions: Ai Pltafe = er-013-1f— Date Wanted: a.m. f_S— P.m. Request &,q we tf-03 1(1( t/evi- Phone No• 3100030 IFirApproved per applicable codes. COMMENTS: EJCorrections required prior to approval. / (r K.....C......, Inspector: ' ate: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection, 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address ULTA #191 PARKWAY SUPERCENTER Date 1/13/2015 17320 S. CENTER PARKWAY For Building Dept. Use PLIIANCE WITI- PA ° 70 - NEC TURWILA, WA 98188 REVIEWED�� Applicant Name: RGLA SOLUTIONS, INC j S Applicant Address: 5100 RIVER RD, STE 125 SCHILLER PARK T�VL, Applicant Phone: 847-671-7452 Project Description Briefly describe mechanical system type and features. Includes Plans j�jj'UE COPY ^.1.. u +� FEB 11 2015 (ILL !r Hog i ofTukwila Drawings must contain notes requiring compliance with commissim Fib i . vi ' ijiiW Fell k ki Compliance Option [ ( Simple System ( :Complex_SyStem s"v :-(- Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU-1 DX LENNOX • LGH120H4B 124 ECONO 12.0 EER N/A ECONO N RTU-2 DX LENNOX LGH12OH4B 124 ECONO 12.0 EER N/A ECONO N RTU-3 DX LENNOX LGH12OH4B 124 ECONO 12.0 EER N/A ECONO N RTU-4 DX LENNOX LGH120H4B 124 ECONO 12.0 EER N/A ECONO N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N RTU-1 GAS LENNOX LGH120H4B 240 ECONO 240 192 80 N RTU-2 GAS LENNOX LGH120H4B 240 ECONO 240 192 80 N RTU-3 GAS LENNOX LGH120H4B 240 ECONO 240 192 80 N RTU-4 GAS LENNOX LGH12OH4B 240 ECONO 240 192 80 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM Sp1 HP/BHP Flow Controls Location of Service RTU-1 FAN 3850 1.00 3.00 CV SUPPLY AIR BLOWER RTU-2 FAN 4000 1.00 3.00 CV SUPPLY AIR BLOWER RTU-3 FAN 3825 1.00 3.00 Cv SUPPLY AIR BLOWER RTU-4 Service Equip. ID EXIST FAN Water Equip Type Heating Equipment Brand Name' Schedule Model No.1 4070 Input Capacity 1.00 Sub - Category 3.00 EFL CV Location SUPPLY AIR BLOWER . v. of Service 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustin1'fipncIt,,olatfasA applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Ecorai e e pti Err M soo(o JAN 3 0 2015 PERMIT CENTER Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address ULTA#191 PARKWAY SUPERCENTER Date 1/13/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na)Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance YES C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 Replaced w/ same YES C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken Replaced w/ same YES C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC M-3 YES C403.2.3 & C403.2.3.2 & C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment M-3 YES C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. M 3 YES C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) M-3 N/A C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. N/A C403.2.3 Maximum air cooled chiller capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss N A / C403.2.3.3 heating/cooling equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria YES C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M-1, M-2 N/A C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp YES C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling M-4, M-5, EMS YES C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M-4, M-5 YES C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions M-3, M-4, M-5, EMS YES C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions - N/A C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions YES C403.2.4.6 Combustion heating equipment Indicate modulating or staged control M-3 N/A C403.2.4.7 Group R1 hoteVmotel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A C403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken N/A C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV N/A C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially N/A / C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) N/A C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions NA / C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery NA / C403.2.6.3 Energy recovery - condenser systems • A Indicate reorote refrig/Eondensers regwinhgR and Use of captured' ergy Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address ULTA #191 PARKWAY SUPERCENTER !Date 1/13/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N/A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) N/A VarC403.2.12.1 cooling t flow we control cooling towers Indicate cooling tower fans requiring variable flow control and method N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N A / C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendino and demand response setpoint adiustment Ducting Systems YES C403.2.7.1 & C403.2.7.3 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements M-4, M-5 YES :::.403.2.7.3.1-: Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M-4, M-5 N/A C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed YES C403.2.7.1 /2 Duct insulation Indicate R-value of insulation on ductwork M-1 Piping Systems YES C403.2.8 Piping insulation Indicate R-value of insulation on piping P-6, P-7 N/A C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems YES C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heatinq/cooling M-3 N/A C403.3 Qualifying 2-pipe heating systems Verify 2-pipe heating -only system does not exceed capacity limits N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers YES C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M-3 YES C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M-3 YES C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M-3 YES C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh M-5 N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) COMPLEX SYSTEMS Complex System Economizers N/A C40341 .. Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. N/A C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation N/A C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A c403.3.1 Air economizer exceptions Indicate.eligible exception(s) taken and provisions to comply with eotion(s) Mechanical Permit Plans Checklist - Page 3 of 3 2012 Washington State Energy Code Compliance Forms tor Commercial, Group R1, and> 3 story R2 and R3 MECH-CHK Revised June 2013 Project Address ULTA #191 PARKWAY SUPERCENTER Date 1/13/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/AC403.2.12Variable C403.4.2 & flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N/A C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method / A CN & C403.4.4 & C4.2.12.103.4.4 Varcooling towers flow control - cooling Indicate cooling tower fans requiring variable flow control and method N/A C403.4.3.4 Hydronic system part load controls reset supply water temp AND reduce flow by a 50% for systems > 300,000 N/A C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/A C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes N/A C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A C403.4.6 recovery Condenser water heat Indicate system provided to pre -heat service water and efficiency N/A C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A C403.5 / 6 Cooler / freezer -evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems N/A C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) EXIST N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability EXIST N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A C404.5 Insulation under water heater Indicate R-10 insulation under tank EXIST YES C404.6 Service water piping insulation Indicate R-value of insulation on i n note exce tions taken p p g' p P-6, P-7 YES C404.7 / 8 Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand EXIST N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas N/A C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters a 4 COP N/A C404.10.1 / 2 Pool heater on /off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0010 DATE: 01/30/15 PROJECT NAME: ULTA BEAUTY SITE ADDRESS: 17320 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Al_kw/ 2r6-I' Building Division IN Public Works Al4A }2-IO Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 02/03/15 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 03/03/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 THREE RIVERS CONST & DEV T'`TC Home Inicio en .Espanol Contact Page 1 of 2 Search L&I A-Z Index Help Day Secure L&I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries THREE RIVERS CONST & DEV INC Owner or tradesperson VAN JR, ROBERT LYNN Principals VAN JR, ROBERT LYNN, PRESIDENT VAN, MICHELLE LYNN, SECRETARY Doing business as THREE RIVERS CONST & DEV INC WA UBI No. 603 158 536 155 Design Place Ste 101 SPARKS, NV 89441 775-825-5248 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................................... Meets current requirements. License specialties GENERAL License no. THREERC891RZ Effective — expiration 01/03/2012— 01/03/2016 Bond ................ Old Republic Surety Co Bond account no. W150111287 Received by L&I 12/05/2011 Insurance State National Ins Co Inc Policy no. XNDP0105800 $12,000.00 Effective date 11/20/2011 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date 10/09/2014 10/05/2014 Expiration date 10/05/2015 Insurance history Savings .................. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ........................................ No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603158536&LIC=THREERC891 RZ&SAW= 03/09/2015