Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0014 - CHURCH OF THE VIETNAMESE MARTYRS - EXHAUST FANS AND COOKING APPLIANCES
CHURCH OF THE VIETNAMESE MARTYRS 6841 S 180 ST M15-0014 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3623049087 Permit Number: 6841 S 180TH ST Issue Date: Permit Expires On: CHURCH OF THE VIETNAMESE MARTY M 15-0014 2/18/2015 8/17/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ARCHDIOCESE OF SEATTLE 710 9TH AVE C/O LAURA TOEPFER, SEATTLE, WA, 98104 KIEN NGUYEN 6841 S 180 ST, TUKWILA, WA, 98188 OWNER AFFIDAVIT - KIEN NGUYEN Phone: (253) 951-6449 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL 2 EXHAUST FANS AND COOKING APPLIANCES IN TEMPORARY STORAGE UNIT. Valuation of Work: $5,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $258.96 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Klet�-')Y€t Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 4: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ***MECHANICAL PERMIT CONDITIONS*** 7: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKJ A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Mechanical Permit No. CO(2, Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 3 CoZ.3O 4- R ca 7 Floor: Tenant Name: V h'11Slb H At PZS New Tenant: ❑ Yes 15,..No Ce7,4::,1 D. I8cc� `� PROPERTY OWNER N m 4 til C z3e1.7113 Addre-7 1' q' /6...-i . , City: �CTZ State: i.4 Zip: Fit c4 CONTACT PERSON - person receiving all project communication Name:V I NCvY k Address l `J . I e=C:'-e-Lt.�- c 1 City: State: 1-, State: la& Zip: q £'leg Phone: ax: Z53.9s1, • Email - tin I C 1,44-1�.*4 t Ca e&t!_.._, GtpM Suite Number: MECHANICAL CONTRACTOR INFORMATION Com an Name: '�, Pl.-C.)t+trijAtfo # Imecm6141c4iL Ace4.3 ot . CcGr-t €;-. City: State: Zip: ���-r-rt...G- c Sil e Phone: ax: ZOKe. • 7 t 754.4 Contr Reg s�o t21 Q 14- 4) Dat%:, - l . (5- IBC Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: j P St -L-C_ 7.- 5041-40c' t_ IF,t kJ- ( ,QPL( -r--rnPe:,12-06a=r Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric Gas ❑ Other: 11:\Applications\Forms-Applications On Line\2011 ApplicationsWlechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Z. Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment • Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed=and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review -applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension oftime for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE IiA.WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: t 3 • t `T' Print Name: C; (�R�I�C—� Day Telephone: 70,Cp • CZ, • 75-- Mailing Address: 5'S S . ,641'1_46J4Tk . 55t ''3 7( S E-teem-G- City - • • State Zip H:\Applications\Porms-Applications On Line\2011 Applications Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $793.06 D15-0028 Address: 6841 S 180TH ST Apn: 3623049087 $408.02 DEVELOPMENT $388.80 PERMIT FEE R000.322.100.00.00 0.00 $384.30 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE R000.322.900.04.00 0.00 $19.22 M15-0014 Address: 6841 S 180TH ST Apn: 3623049087 $209.16 MECHANICAL $199.20 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.96 PG15-0009 Address: 6841 S 180TH ST Apn: 3623049087 $175.88 GAS $167.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $135.00 TECHNOLOGY FEE $8.38 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4563 R000.322.900.04.00 0.00 $8.38 $793.06 Date Paid: Wednesday, February 18, 2015 Paid By: KIEN NGUYEN Pay Method: CREDIT CARD 87977Z Printed: Wednesday, February 18, 2015 8:37 AM 1 of 1 S SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R4467 DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID $341.48 D15-0028 Address: 6841 S 180TH ST Apn: 3623049087 $249.80 DEVELOPMENT $249.80 PLAN CHECK FEE R000.345.830.00.00 0.00 $249.80 M15-0014 Address: 68415180TH ST Apn: 3623049087 $49.80 MECHANICAL $49.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 PG15-0009 Address: 6841 S 180TH ST Apn: 3623049087 $41.88 GAS $41.88 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R4467 R000.322.103.00.00 0.00 $41.88 $341.48 Date Paid: Wednesday, February 04, 2015 Paid By: BRODERICK ARCHITECTS PLLC Pay Method: CHECK 17035 Printed: Wednesday, February 04, 2015 2:25 PM 1 of 1 CRWS /I)/6=ooi/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: ti Type of Inspection: / Address: to w 1,S /F6)z-h sT Date Called: Special Instructions: I1I/4 Date Wanted: - c./-/`5.-- a.m. p.m. Requester: / Phone No: 77cL fctei0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: zcfrvip-,t/a),V, 1 ry ecl l et) o Twc�t�� t S Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 7/1/2015 KIEN NGUYEN 6841 S 180 ST TUKWILA, WA 98188 RE: Permit No. M15-0014 CHURCH OF THE VIETNAMESE MARTY 6841 S 180 ST Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/17/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/17/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0014 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT C fD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0014 DATE: 02/04/15 PROJECT NAME: CHURCH OF THE VIETNAMESE MARTYRS SITE ADDRESS: 6841 S 180 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 02/05/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 03/05/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ss. 4-ENi NiaurENI [please print name] , states as follows: PERMIT NO: 11/11-0O-R+ P41-bbm 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. ner/Owner's Signed and sworn to before me this day of `'4 �/t.G�(�lJ , 20J. NOTARY PUBLIC in and for the State of Washington Residing at 'l . j , County Name as commissioned: � %III Vf/(- My commission expires: D 1 9' --/c- 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. REVISIONS BY Vulcan VSP100 110 kBTU Single 2-Ring Burner Stock Pot Range Vutcan VSPIOOIVSPI00-1IVSPi00-2 0.6 IN. WC. PRESSURE 1"x10' IRON PIPE ----- IQ ncluded Options Reviews Mfg.: Vulcan Models: VulcanVSP100, VulcanVSP100-1, Vulcan-VSP100-2 This item is brand new and ships directly from the supplier. Please note the image above is for reference only. Item: Vulcan 110 kBTU Single 2-Ring Burner Stock Pot. Range Model:VSP100-1, VSP100-2 Features • Stainless steel front and sides. • Heavy cast iron top grate(s). • Two concentric 55,000 BTU/hr. ring -type burners per 18" section; 110,000 BTU/hr. input persection. • Standing pilot ignition system. • Two infinite heat control valves per section. • Heat shield to protect control valves. • 3/4" rear gas connection and gas pressure regulator. • One year limited parts and labor warranty. HOBART SERVICE WILL PERFORM A "FREE EQUIPMENT CHECK OUT" FOR ALL VULCAN EQUIPMENT. PLEASE CALL US DIRECTLY FOR MORE INFORMATION ON THIS SERVICE. 115/21715 DAYTON DorablastVent,DirectDrfve,5-1M Ii- Deert,blastCent^Irugel Roof Ventilator's - 5DVR8I5DVR8-Grainger IndusttIal St illy FIVACand Refdgeratoe. S RoafVontittlers 1 DowektlnetCentrifugal Roof VoD1n1irs S 11affn6betVorrt,DrnotDrlvs,3-1(4h Sack la Product Family Ai How crrn we irrtnrcvo our Product Images? ' csmper• Technical $poc fro- m Dcweblast Ventilator Drive Type Direct -- Number of Spends 3 Vs9,eel Die. CFM 41) 0.060.11. SP CFM f 0.12541. SP 4201555/701 Downblast Vent, Direct Drive, 8-1/4 In DAYTON Sleet 71111 r4Y4 Price. $552,00 / each Pet er*fme et* eetatreetder EyeryaltiT„ Add • Add to List rt Cheek Avethbinj Pam► Add Repair & Replacement Cr/verse* tor101.95each, • © View RspilrPartetor this Nem 1=t ia. 1 1': '1.1' Be the first In wrtt6 a review I Ask 8.Answer Item # 50Vila Mfr. Model # 50VR8 Catalog Pagew# 4144 Shipping weight 22.5414e. • Country of Origin USA I Country oft>re'nissob/MID champ. 520nWlfrb5 CFM 0,25041,.5P 2931471V533 CFM 0,3754,. SP 43731557 CFf.10 0,5a0-11.SP .H473 CFM Q9 0.525-4.8P 43S5 CFM 0,7504.SP 44. t,e,na9 0.1254L SP 3.9t5AJL5 rg 6 Ft. 5y,netia t{g 0250. L 5P 4.215.517.4 m 6FI,. Motor Vorege 115 Passe Ht ea UNSP$G # 40101502 RP 105011300(1550 Open Whit 11r Bean Lorgle Base I Leigh I. Overall Dia. 10- 14M" O. vrell Height 14-5fd" Shn:10?.0. Whuol End 1fr Mounf,i,g Lt.taiR n Roof SltaSCie. Sheave End 112" Mex. filet Temp. Hove Wit Speed Control 130 Degrees Backwardlnelnad Csne1Nugd 454112 Speed Controllable yes Adt.12 311'H Root 4C570 Curb Stock*. anufactiturer In Manufacturer Model Model. List price: Uses Gas?::' Vulcan` VSP100 VSP.10,o-1 VSP1002 $1;332.00.,::. Yes.. 110„000 Iiriiiinslons Weight, Depth; . Hight: 145 1:bs 18 in 24i 23 in. hipping InfarrrlatNn ;:, Shipped from Ft Mitchell, KY 41017 Packing Charge: usto net Pick, tip Not Available {Shipping Only 0.6 IN. WC. PRESSURE 1 "x:32' IRON PIPE EXISTING KITCHENAREA EXISTING 2 PSI. 3,000 CPH GAS METER MODEL U 3H115 EXISTING 2" 2 PSI EXISTING REDUCING PRESSURE REGULATOR SENSUS GAS REGULATOR Model # 243-12-2 12" ABOVE GRADE IRON PIPE - NEW REDUCING PRESSURE REGULATOR SENSUS GAS REGULATOR Model # 243-12-2 16"x16" MAKE—UP AIR LOUVERED WINDOW 40'x8' CARGO CONTAINNER UNDER A SEPARATE PERMIT VENTILATION SIZING 40'x8'x8'ROOM SIZE EXHAUST FANS 0 .125 SP EXHAUST FAN INLET 425 CFM AT LOW SPEED (x2 ) 700 CFM AT HI SPEED (x2 ) 2,560 CF 18" ROUND 840 CFM 1400 CFM 1.77 SF 50,400 CFH 84,000 CFH 237 FPM 395 FPM MAKE—UP AIR LOUVERED WINDOW 16"x16" 1.77 SF AIR CHANGE AT LOW SPEED AIR CHANGE AT . HI SPEED 19.69 / HR 32.81 / HR — NEW (TEMPOARY VENTILATION ) ONLY FOR VIETNAMESE NEW YEAR USED IN 4 WEEKS /YEAR FOR REMOVING STEAM , _VAPOR ANDHEAT FROM STEAMING EQUIPMENTS — MAKE—UP AIR LOUVERED WINDOW WITH FILTER AUTO. FIRE SHUT—OFF VALVE 0.6' IN. WO. PRESSURE 2"x10' IRON PIPE O���HARD'�CAPEDAFTER USE) eo GAS UNION Ro% CipO 00R 1100 1460 2560 GAS SIZING GAS SIZING BASE ON 2012 INTERNATIONAL FUEL GAS CODE TABLE 402.4 1050 1391 2441 3000 STOCK POT RANGE VULCAN VSP 100 NEW ITEMOARY) GAS LOAD PROPOSED EXISTING GAS LOAD (KITCHEN EQP. tJ4V-A-611111117 TOTAL' NEW t EXISTING GAS LOAD _ EXISTING GAS METER MODEL tt 3HI75 2 — NEW (TEMPOARY GAS) ONLY FOR VIETNAMESE NEW YEAR USED IN 4 WEEKS /YEAR. — 0.6 IN.W.C.,w NATURAL GAS OF 0.60 SPECIFIC GRAVITY BASE ON PRESSURE DROP OF 0.5 IN. WATER COLUMN _ — 60' MAX. FR: GAS REGULATOR TO THE MOST REMOTE0 UTLET - EXISTING & NEW GAS PIPING = IRON PIPE SCHEDULE # 40 (RUN ABOVE GROUND) (/A R 0.6 IN. WC. PRESSURE 2"x32' IRON PIPE 16"x16" MAKE-UP AIR LOUVERED WINDOW FILE COPY Permit No. M i Oqi Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and conditions is acknowledged: Date: :.►al Z i I B City of Tukwila BUILDING DIVISION REVISIONS . No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal . and may include additional plan review fees. I SEPARATE PERMIT REQUIRED FOR: ❑ echanical ICJ Electrical iumbing t Gas Piping Ci y of Tukwila B.I.P c=!NG DIVISION M)S0O11-J S'Oce va11Vs Ity tJ4 �ti.la pia RECEIVED CITY OF TUKWILA FEB 0 4 2015 PERMIT CENTER INSPECTOR: THIS IS A TEMPORARY INSTALLTION NOVEMBER 2014 - FEBRUARY 2015. CONTAINER MUST BE REMOVED FROM THE SITE AFTER FEBRUARY. SEE L14-0070. STAR PLUMBING • MECHANICAL 3939 S. GRAHAM ST. TEL: (2O6)119-154 WA. STATE LIC.# STARPM*999NW S. 18Oth STREET co a) a 0 DRAWN : NAM DAO CHECKED : DATE : 0I/I5/I5 SCALE : AS NOTED JOB NO. : 001 SHEET Emi Max, Cperallr.g Amps 5.4511.5V12.44 Aff1.5 318'H Roof Cub 40453 Slack tdo, OF . 1 SHEETS