Loading...
HomeMy WebLinkAboutPermit M15-0026 - MICROSOFT - FIRE/SMOKE DAMPERSMICROSOFT 3355 S 120 PL M15-0026 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 1023049082 3355 S 120TH PL BLDG 5 Project Name: MICROSOFT MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M15-0026 3/25/2015 9/21/2015 Owner: Name: SABEY CORPORATION Address: 4TH FLOOR 12201 TUKWILA INTL BLVD, SEATTLE, WA, 98168 Contact Person: Name: JIM THOMAS Address: 5005 THIRD AVE S , SEATTLE, WA, 98134 Contractor: Name: Address: License No: Lender: Name: Address: MCKINSTRY CO LLC 5005 3RD AVE S , SEATTLE, WA, 98124 MCKINCL942DW /1/ Phone: (206) 763-4819 Phone: (206) 762-3311 Expiration Date: DESCRIPTION OF WORK: INSTALL TWENTY-FOUR (24) FIRE/SMOKE DAMPERS Valuation of Work: $56,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $938.74 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: i✓' Date: 3) 616 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: ? �s l s Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 3: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ***MECHANICAL PERMIT CONDITIONS*** 6: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 7: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0704 SMOKE CONTROL TEST Tenant Name: CITY OF TUKW),__ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: --1 O-i (For ofce use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1023049082 Site Address: 3355 S 120th Pl Suite Number: Floor: 2nd MS TUK 5 WAN Room New Tenant: ❑ Yes ®..No PROPERTY OWNER . . Name: Sabey Corporation Address: 12201 Tukwila International Blvd - 4th Flr City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jim Thomas w/ McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 763-4819 Fax: (206) 762-2624 Email: permits@mckinstry.com MECHANICAL CONTRACTOR INFORMATION Company Name: McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle - State: WA Zip: 98134 Phone: (206) 762-3311 Fax: (206) 762-2624 Contr Reg No.: MCKINCL942DW Exp Date: 03/16/2016 Tukwila Business License No.: BUS-0994320 Valuation of project (contractor's bid price): $ 56,000 Describe the scope of work in detail: Installing twenty-four (24) fire/smoke dampers. Use: Fuel Type: Residential: Commercial: New ❑ Replacement ❑ New ., ❑ Replacement ❑ Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper 24 Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AJGEN /J� Signature: ,l%ii rs) G Print Nam • Jim Thomas w/ McKinstry Co LLC Mailing Address: 5005 3rd Ave S Date: 03/09/2015 Day Telephone: (206) 763-4819 Seattle WA 98134 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docs Revised: August 2011 bh Page 2 of 2 LJ Cash Register Receipt City of Tukwila Receipt Number R4898 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $666.72 M15-0026 Address: 3355 S 120TH PL BLDG 5 Apn: 1023049082 $666.72 MECHANICAL $641.07 PERMIT FEE R000.322.100.00.00 0.00 $512.85 PLAN CHECK FEE R000.322.102.00.00 0.00 $128.22 TECHNOLOGY FEE $25.65 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4898 R000.322.900.04.00 0.00 $25.65 $666.72 Date Paid: Wednesday, March 25, 2015 Paid By: MCKINSTRY CO Pay Method: CHECK 12890 Printed: Wednesday, March 25, 2015 11:44 AM 1 of 1 CRWSYSTEMS Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $272.02 M15-0026 Address: 3355 S 120TH PL BLDG 5 Apn: 1023049082 $272.02 MECHANICAL $261.56 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $176.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $52.31 TECHNOLOGY FEE $10.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4785 R000.322.900.04.00 0.00 $10.46 $272.02 Date Paid: Tuesday, March 10, 2015 Paid By: JIM THOMAS MCKINSTRY Pay Method: CREDIT CARD 004625 Printed: Tuesday, March 10, 2015 11:54 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 /415--0o2.6 'Project: Cekt-ULP t.---( v( t_ Type of Inspec n: , io"r1 (A_cti Address: 135-1- . /7° ftta Date Called: Specia Instructions: De atW7tedi).3 _ ( r — a.m. P.m. RequAster: 5hC(LA"-& , f CoArt Phone No: 7 03- 3 (12-- -7:6 - 2- pproved per applicable codes. El Corrections required prior to approval. CO MENTS: Inspector: Z.c...„ Date: r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 • f r Pro'ect: 6....r voc_tro Typeyspecton: f Fr kt-ed Date Calltd: 2-0G - 5qg - 5 7 e.tz ot F f Alls5.0 (.2_011..k a_ Special Instrugtions: 0--(5611. 101114 km 6)4_, , C÷IIIISICA0 Date Verite....... Is_ a,m. p.m. Requnterd c /14:7 feY&S467 ,...7:00. zstra. Approved per applicable codes. Corrections required prior to approval. C MMENTS: t_ jd 5„.„ 5. ft, le,@2 cectr e inspector: r- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 r Pr?ect: Z.- TypKinspectiory 4,k - Most% Address: acri 3-337 fd' ' (2-orV-e, 'lids Date CaIIA: Special Instructions: 1 i AA4 ....._ , f , ikt( Gir- 0,5•01------r . Date Wanted: -2_6-0- a.m. P.m. 3 Requester: if 9 Ja-fetecg Aitc,,K-( kf 17 Phone No: z5;z ---3 q' 6 —t7 Li '2- co Approved per applicable codes. Corrections required prior to approval. MEN7(Af-- irmcA\T‘v(3 fl(rOzt&Alf CO (qc Inspector: Date _LI__ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER /4_ &-/K PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: orm - Type of Inspection: fi/f 7"agg - s Address: Suite #: ,135 5 5. /2-o 727 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,AsS 1te°A tip -- / ems Id, A/ 1/pc,/ i Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Sso dii3' Date: ��Z j S'— Hrs.: /. 6— / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 RUSKIN® FILE Copy °•,‘ 1111.I 3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816) 761-7476 -•----"F -X-{$ 6 765-8955 FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 11/2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION The FSD36 series combination fire and smoke dampers point -of -origin fire and smoke containment. The FSD36 i high strength V-groove blade and control closure technol flexibility in static or dynamic smoke management systems. The FSD36LP low profile and low pressure drop combin and smoke damper provided with an integral sleeve/tram all FSD36 series dampers may be installed vertically in wal izontally in masonry floors and are rated for airflow and I either direction. STANDARD CONSTRUCTION L`zw. Description FSD36 FSD36LP Frame 5" x 16 gage (127 x 1.6) galvanized, single piece, hat -shaped channel, struc- turally superior to 13 (2.3) gage channel frame. Integral sleeve and frame 20 (1.0) gage galvanized single piece. Blades 6" (152) wide and 16 (1.6) gage galvanized steel. Blades are approximately 6" (152) on center. One-piece low profile aerodynamic shape, 20 gage (1.0) galvanized. Bearings Stainless steel sleeve type, pressed into frame. Stainless steel sleeve type, pressed into frame. Jamb Seal Stainless steel, flexible metal compression type. Stainless steel, flexible metal compression type. Stainless steel, flexible metal compression type. Blade Seal Silicone edge type for smoke seal to 450°F (232°C) and galvanized steel for flame seal to 1900°F (1038°C) mechanically fastened to the blade edge. Linkage Concealed in frame. N/A DAMPER SIZES Sizes indicated below are for ratings of 2000 FPM (10.2 m/s) and 4 in. w.g. (1 kPa). MINIMUM SIZE FSD36LP - 6"w x 6"h (152 x 152) FSD36 - 8"w x 6"h (203 x 152) MAXIMUM SIZE FSD36LP Single Section Vertical or Horizontal — 36"w x 14"h (914 x 356) FSD36 Single Section Vertical or Horizontal — 36"w x 48"h (914 x 1219) FSD36 Multiple Section Vertical 126"w x 96"h (3200 x 2438) or 72"w x 122"h (1829 x 3099) Multiple Section Horizontal Electric Actuator — 120"w x 96"h (3048 x 2438) Pneumatic Actuators — 144"w x 96"h (3658 x 2438) CONTROLLED CLOSURE DEVICE (HEAT -ACTUATED) EFL (Electric Fuse Link) - 165°F (74°C) standard. 212°F (100°C), 250°F (121°C), 350°F (177°C) available. PFL (Pneumatic Fuse Link) - 165°F (74°C) standard. 212°F (100°C), 285°F (141°C) available. NOTES 1. Dampers are furnished approximately 1/4" (6) smaller than given opening dimensions. 2. Dimensions shown in parentheses ( ) indicate millimeters. REVIEWED FOR ZDE COMPLIANCE gyforludes APPROVED ion fire MAR 19 2015 design. or hor- kage Ott dit f Tukwlta DING OIV,SIO MAXIMUM OPERATIONAL RATINGS Description FSD36 FSD36LP UL555S Leakage Rating Class II Class II UL555 Hourly Rating 11/2 Hour 11/2 Hour Maximum Velocity 2000 FPM (10.2 m/s) 2000 FPM (10.2 m/s) Maximum Pressure 4 in. wg (1 kPa) 4 in. wg (1 kPa) Temperature 350°F (177°C) 350°F (177°C) • • • • • • • OPTIONS FM Approvals as Specification Tested Product. DTS (Damper Test Switch) test switch for cycle testing. TS150 FireStat for reopenable operation in dynamic smoke man- agement systems. DSDF/DSDN Duct Smoke Detector (Flow rated or No -Flow). SP100 Switch Package to allow remote indication of damper blade position. MCP control panels for test purposes or smoke management systems. Factory Sleeves of various lengths and gages to ensure field compliance with UL installation requirements. I� FAST Angle factory supplied for labor saving angle opka� , ram+, tion. Other angles of various sizes and gagesdls O F T U K W I L A side or two -side installation. CC..iTY 15 UL CLASSIFIED UL555 Listing R5531, UL555S Listing R5531 MAR 1 0/ 10 PERMIT CUNT Model FSD36 series meets the requirements for smoke dampers established by: • National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B and 101 • ICC International Building Codes • CSFM California State Fire Marshal Listing (#3235-0245:0124) • New York City (BSA Listing #176-82-SM) ER Spec FSD36-211/Replaces FSD36-80L S TED TICE OR OBLIGATION. ©Ruskin 2011 AMCA LICENSED LEAKAGE AND AIR PERFORMANCE DATA amca OERTICIED RATIA6f AIR performance MR movEmEnT nnD CORTROI msocinTIOn InTERnnTlonnt. Inc. Ruskin Company certifies that the FSD36 shown hereon is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance for the FSD36. The FSD36LP pressure drop depicted on the chart below is preliminary data only. AMCA Certified testing pending. To determine the AMCA Licensed air performance: Locate the applicable feet per minute face velocity on the bottom of the velocity vs. pressure drop chart below. Move up the chart to the most appropriate size damper line. From the intersection point, move left to determine the pressure drop on the left side of the chart. For other damper sizes refer to Air Performance Data For All Fire and Smoke Dampers spec sheet. PRESSURE DROP (INCHES W.G.) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 .09 .08 .07 .06 .05 .04 .03 .02 .01 VELOCITY vs. PRESSURE DROP 04A�ry } ^ti Ilry 40 y 2 3 4 6 7 8 9 100 500 1000 2 3 4 6 7 8 9 5000 10000 FACE VELOCITY — FEET/MINUTE AMCA Fig. 5.3 EXTENDED OPERATIONAL RATINGS (FSD36 ONLY) The UL555 and UL555S Test Standards require all fire smoke dampers to prove closure or operation against heated air flow veloci- ties of at least 2,000 feet per minute (10.2 m/s) and 4 inches of water (1 kPa) and minimum operating temperature of 250°F. All Ruskin fire smoke dampers in all sizes meet the minimum requirements. In addi- tion Ruskin FSD36 dampers exceed those minimum requirements. Ruskin FSD36 dampers exceed these minimum requirements in many cases. 2,000 FPM Fail Close Operation MODEL SIZE STATIC PRESSURE TEMPERATURE INSTALLATION FSD36 126" x 96" or 72" x 122" 4" w.g. 350° Vertical FSD36 144" x 96" 4" w.g. 350° Horizontal FSD36LP 36" x 14" 4" w.g. 350° Vertical or Horizontal ACTUATOR REQUIREMENTS * UL555S requires that all smoke dampers have factory mounted actuators in order to bear the UL label. • Fire smoke dampers larger than single section may require mul- tiple actuators. See "Smoke Damper Multiple Section Detail" spec sheet for details. • Ruskin's smoke dampers are UL555S labeled with either electric FSD36LP SLEEVE DIMENSIONAL DATA or pneumatic actuators mounted internal (in air stream) or exter- nal (out of air stream). • Fire smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous clo- sure. All field wiring shall be in accordance with applicable codes, ordinances and regulations. The drawing shows the standard position of the FSD36LP when installed. The mounting location provides enough space for the actuators, controls (FAST) retaining angles and duct connections. The minimum sleeve length is 20" (508). Consult Ruskin for shorter sleeve lengths. NOTES 1. The entire frame is not required to be installed within the wall. The center line of the closed blade, should be contained within the wall. 2. See basic UL installation instructions for complete installation requirements. FSD36 SLEEVE DIMENSIONAL DATA 20" (508) or — 24" (610) Wall Depth 11 'H' Dim. 101/2" (267) Min. 12" (305) Max. The drawing and corresponding table show the position of the damper when mounted in a factory sleeve. The standard mounting locations provide enough space for the mounting of actuators, controls, installation of retaining angles, and duct connections. The minimum factory sleeve length is 17",(432). Consult Ruskin for shorter sleeve lengths. The standard location of a damper mounted in a factory sleeve ("L" dimension) is shown at right. "Minimum Sleeve Length Formula: Sleeve Length = "L" dimension + wall/floor thickness + 3" sleeve non - motor side NOTE: 1. The entire damper frame is not required to be installed within the wall. The damper blades, when closed should be contained within the wall. 2. See basic UL installation instructions for complete installation requirements. "Sleeve Length _ `L' _ Wall/ Dim. Floor 3" (76) Ref. `H' Dim. 1 `H' High and tinder "Sleeve Length L' Wall/ 3" (76) -Dim. Floor Ref. Over `H' High `H' Dim. Actuator Side All dampers with EFL or PFL All dampers with TS150, SP100 or DTS Electric Actuators Pneumatic Actuators ,H, Over10" (254) High H, 10"(254)( High and Under ,H, " 21 Over533 (533) High (see note) 'H' 21" ) High and Under (see note) 331-4827(P) 331-2961(P) 331-3060(P) `H' Over 28" (711) High `H' 28" (711) High & Under 'H' Over 32" (813)High High `H' 32" (813) & Under `H' Over 40" (1016) High `H' 40" (1016) High & Under "L" 71/8" (181) 105/8" (270) 71/8" (181) 105/8" (270) 71/8" (181) 105/8" (270) 71/8" (181) 105/8" (270) 71/8" (181) 105/8" (270) Note: The 21" (533) dimension becomes 32" (813) when the MS4120, MS8120, GGD221 or FSNF and FSAF Series are utilized. FSD36 SERIES SPACE ENVELOPE Combination fire smoke dampers are required by the UL listing to have all actuators and acces- sories factory mounted, wired and/or piped. The Ruskin standard is for the actuator to be located on the right hand side of the damper (onto a fac- tory installed sleeve or side plate) as viewed from the jackshaft face of the unit. Larger units may require multiple actuators which are located on the right, left and maybe intemal mount locations. See the "Multiple Section Detail" specification sheet for details. Ruskin's fire smoke dampers are not air flow directional, so the dampers may be rotated 180° or tumed over as long as the blades are running horizontally in a position to accommo- date installation obstructions. The adjacent chart indicates an "S" and a "T" dimension for the space envelope that each actu- ator requires for installation. The "S" dimension is the "side" clearance, the "T" dimension is the "top" clearance required for the various actuators approved for use with Ruskin fire smoke dampers. Ruskin recommends 6" (152) of additional space beyond the "S" dimension for ease of mainte- nance. ACTUATORS S T ML, FSLF, H2000 MS4209 4" (102) 2" (51) FSNF, FSAF, MS4120 5" (127) 5" (127) 331-4827 5" (127) 6" (152) 331-2961 8" (203) 8" (203) 331-3060 9" (229) 11"(279) NOTES 1. The dimensions shown in the chart above are for dampers 14" (356) tall. 2. Dampers shorter than 14" (356) tall, increase the "T" dimension by 1" (25) for every 1" (25) the damper is less than 14" (356). 3. Dampers taller than 14" (356) high reduce the "T" dimension by 1" (25) for every 1" (25) the damper height is greater than 14" (356). Example: a) 12" (305) tall damper with a FSLF actuator, 'T' = 2" (52) and "S" = 4" (102). b) 18" (457) tall damper with a FSNF actuator, 'T" = 1" (25) and "S" = 5" (127). FSD36 INTERNAL MOUNT ACTUATOR DIMENSION Ruskin model FSD36 has been tested for internal mount actua- tors and accessories. These applications may be preferred where space is limited on the outside of the damper. Internally mounted actuators do not require the damper to have a factory installed sleeve or side plate. 'x, x Dim. Dim. ,B, Dim. ,B, Dim. ACTUATORS B Dim and Above B Dim and Above B X B X ML, FSLF, H2000 MS4209 10" (154) 10" (154) 18" (457) 71/2" (191) FSNF, FSAF, MS4120 12" (305) 123/4" (324) 21" (533) 51/2" (533) 331-4827 16" (406) 15" (381) 21" (533) 71/2" (191) 331-2961 16" (406) 17" (432) 24" (610) 71/2" (191) 331-3060 20" (508) 19" (483) 26" (660) 9" (229) (Model FSD36LP not available with internal mount actuators) FSD36 DIMENSIONAL INFORMATION 'B, FSD36 Style Sleeve Length FSD36 Style C and WC FSD36LP Style C Sleeve Length Dia.+2"(51) Dia. Sleeve ACTUATORS TO BE INTERNAL FSD36 Style LO,CO & WO FSD36LP Style LO & CO Dia. +2"(51) See Note FSD36 Style R, CR and WR FSD36LP Style R & CR Sleeve Length 6" (152) Height DUCT TRANSITION CONNECTIONS FSD36 Series dampers may be supplied with Round, Oval and Rectangular duct connections. Style Description B Units Under 6" Tall R Round Non -Sealed (Low Pressure) CR Round Sealed (Medium Pressure) WR Round Welded (High Pressure) C Rectangular Sealed (Low and Medium Pressure) WC Rectangular Welded (High Pressure) LO Oval Non -Sealed (Low Pressure) CO Oval Sealed (Medium Pressure) WO Oval Welded (High Pressure) The square damper size will be 2" (51) larger in width and height than the round, oval or rectangular duct size ordered. p �1 FSD36(LP) Style B A FSD36LP Style A MINIMUM and MAXIMUM SIZES Round Transitions Minimum 4" (102) diameter Maximum 94" (2388) diameter Rectangular and Oval Transitions Minimum 6"w x 4"h (152 x 102) Maximum 118"w x 94"h (2997 x 2388) in diameter `B' Style Transitions Minimum height 4" (102) `B' style transitions are utilized on units where the damper height is less than 6" (152). Consult Ruskin for other available styles and sizes. Note: For medium pressure units (Styles CR, C and CO) the collar extends 11/2" (38) beyond the sleeve length and for low pressure and high pressure units (Styles R, WR, WC and LO) the collar extends 21/2" (64) beyond the sleeve length. Approximate damper assembly weight: 17 lbs. per sq. ft. for Style A assembly • SPECIFICATION Combination fire smoke dampers meeting or exceeding the follow- ing specifications shall be furnished and installed at locations shown on plans or as described in schedules. Combination fire smoke dampers shall be produced in an ISO 9001 certified factory and shall be warranted to be free from defects in material and workmanship for a period of 5 years after date of shipment. Dampers shall meet the requirements of NFPA80, 90A, 92A and 92B and shall have a fire rating of 11/2 hours in accordance with the latest edition of UL555 and shall be classified as Leakage Class II Smoke Dampers in accordance with the latest version of UL555S. Dampers shall be AMCA Licensed and shall bear the AMCA certi- fied rating seal for air performance. AMCA certified testing shall verify pressure drop does not exceed .03" w.g. at a face velocity of 1000 fpm on a 24" x 24" (610 x 610) damper. Damper frame, where size permits, shall be constructed using the UniFrame Design Concept (UDC) and shall be minimum 16 (1.6) gage galvanized steel formed into a structural hat channel superior to 13 gage (2.30) channel frame. Assemblies less than 36" (914) wide x 14" (356) high shall be Low Profile (LP) design to maximize the free area of these smaller dampers. Damper blades shall be single skin 16 (1.52) gage galvanized steel with three longitudinal grooves for reinforcement. Jamb seals shall be stainless steel com- pression type. Bearings shall be stainless steel, permanently lubri- RUSKIN® 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 www.ruskin.com cated sleeve type turning in an extruded hole in the frame for maxi- mum life. Combination fire smoke dampers and their actuators shall be qual- ified in accordance with UL555S to an elevated temperature of 250°F (121°C) or 350°F (177°C) depending upon the actuator. Appropriate electric or pneumatic actuators (specifier select one) shall be installed by the damper manufacturer at time of damper fabrication. Electric actuators, factory installed on dampers, shall have been tested for prolonged periods of holding (minimum 1 year) with no evidence of reduced spring return performance. Each damper shall be rated for leakage and airflow in either direction through the damper. In addition to the leakage ratings already specified, the dampers shall be AMCA licensed for Air Perfor- mance. Optional FM Approvals Specification Each combination fire smoke damper shall be listed in Factory Mutual (FM) approvals Specification Tested Product and labeled accordingly. Combination fire smoke dampers shall be Ruskin FSD36 Series. (Consult www.ruskin.com for electronic version of this "Quick" spec as well as for complete 3-part CSI MasterFormat Specifications) Printed on recycled paper using vegetable based inks ,'3°%7 RUSKIN® 3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 CD36 LOW LEAKAGE CONTROL DAMPER GALVANIZED STEEL STANDARD CONSTRUCTION FRAME 5" x 1" x 16 gage (127 x 25 x 1.6) galvanized steel hat channel rein- forced with corner braces for structural strength equal to 13 gage (2.28). Low profile 31/2" x 3/8" x 16 gage (89 x 10 x 1.6) galvanized steel channel top and bottom frame on dampers under 13" (330) high. BLADES 6" (152) wide, 16 (1.6) gage galvanized steel blades approximately 6" (152) on center. Parallel or opposed action. SEALS Blade edge is PVC coated polyester fabric mechanically locked into blade edge. Jamb is flexible metal, compression type. BEARINGS Synthetic. LINKAGE Concealed in frame. Exposed linkage optional. AXLES 1/2 " (13) plated steel hex. CONTROL SHAFT 6" (152) x 1/2 " (13) diameter. Outboard shaft support bracket supplied with all single section dampers for field mounted actuators. Factory - installed jackshaft supplied with all multiple section dampers. MAXIMUM SIZE Single section — 48"w x 72"h (1219 x 1829). Multiple section assembly — Unlimited size. MINIMUM SIZE Single blade — 5"w x 5"h (127 x 127). Two blades, parallel or opposed action, exposed linkage — 8"w x 14"h (203 x 356). Two blades, parallel or opposed action, concealed linkage — 5"w x 10"h (127 x 254). TEMPERATURE LIMITS -25°F (-32°C) minimum and +180°F (+83°C) maximum. SHIPPING WEIGHT Approximately 7 lbs./sq. ft. NOTES • Dimensions shown in parenthesis ( ) indicate millimeters. • Units furnished approximately 1/4" (6) smaller than given opening dimensions. FEATURES The CD36 offers sturdy, steelconstruction with interlocking frame design. Damper locks together without bolts, screws, or rivets that could shake loose. Frame corners are internally braced to reduce racking. Axles positively lock to blades without screws or welds. Non-stick, noncorrosive bearings assure long life and ease of operation. Axles and bearings combine with a shake proof linkage for low mainte- nance operation. When tested in accordance with AMCA Standard 500, the CD36 also exhibits low leakage performance that exceeds the frequently specified, 10 cfm/sq. ft. at 4" w.g. requirement. OPTIONS Options available at additional cost include: • Enamel and epoxy finishes. • Factory -installed, pneumatic and electric actuators. • SP100 Switch Package to remotely indicate damper blade posi- tion. • Heavier frame construction with U-channel frame. • Front, rear or double flange frame with or without bolt holes. • 304 stainless steel construction. • Thrust washers for vertical blade installation. Spec CD36-704/Replaces CD36-104 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. ©Ruskin 2004 CD36 PERFORMANCE DATA AND INSTALLATION INFORMATION Damper ' Width Maximum System Pressure . Maximum System Velocity " %. Leakage* % o of max. flow CFM/ .. sq. ft. 48" (1219) 2.5" w.g. 1500 fpm 0.25 3.7 36" (914) 3.0" w.g. 1500 fpm 0.25 3.7 24" (610) 4.0" w.g. 1500 fpm 0.32 4.8 12" (305) 5.0" w.g. 1500 fpm 0.47 7.0 *Leakage information based on pressure differential of 1" w.g. tested per AMCA Publication 500. Pressure Drop - Damper Open 24" x 24" size) 0.7 17.78 Static Pressure Drop in INCHES and MILLIMETERS of WATER 0.5 12.7 0.3 7.62 0.2 5.08 0.1 2.54 .07 1.78 .05 1.27 .03 .75 .02 .51 .01 200 300 500 700 1000 2000 3000 60.96 91.44 152.40 213.36 304.80 609.60 914.40 Air Velocity in FEET and METERS per minute through FACE AREA. Tested per AMCA Std. 500, Fig. 5.3, ductwork upstream and down- stream. SUGGESTED SPECIFICATION The CD36 is structurally designed for velocities to 2000 fpm and above. Turbulence may produce objectionable noise in some conditions with velocities above 1500 fpm. Dampers may tolerate higher pressures and velocities than those listed here. Conservative ratings are presented inten- tionally in an effort to avoid misapplication. Consult Ruskin or your Ruskin representative when a damper is to be applied in conditions exceeding recommended maximums. INSTALLATION CD36 IS NOT RECOMMENDED FOR INSTALLATION WITH BLADES RUNNING VERTICALLY unless ordered with thrust washers. For proper installation, damper must be installed square and free from racking. Actuator must be installed on linkage side. Opposed blade dampers must be operated from a power blade or shaft. See "Induct Mount Control Dampers Installation Instructions" for details. BRACING OF MULTIPLE SECTION DAMPER ASSEMBLIES The CD36 is intended to be self supporting only in its largest single section size. Multiple section damper assemblies may require bracing to support the weight of the assembly and to hold against system pressure. Ruskin recommends appropri- ate bracing to support the damper horizontally at least once for every 8' of damper width. Vertical assemblies and higher system pressures may require more bracing. Furnish and install, at locations shown on plans, or in accordance with schedules, control dampers that meet the following minimum construction standards. Frame shall be 16 gage (1.6) galvanized steel structural hat channel with tabbed corners for reinforcement. The blades shall be single skin, 16 gage (1.6) galvanized steel with three longitudinal grooves for reinforcement. Blade edge seals shall be PVC coated polyester fabric suitable for -25°F to +180°F (-32°C to +83°C) mechanically locked into the blade edge. Adhesive or clip -on type seals are unacceptable. Jamb seals shall be flexible metal, compression type to prevent leakage between blade end and damper frame. Blade end overlapping frame is unacceptable. Bearings shall be corrosion resistant, molded synthetic sleeve type turning in an extruded hole in the damper frame. Axles shall be hexagonal positively locked into the damper blade. Linkage shall be concealed out of airstream, within the damper frame to reduce pressure drop and noise. Submittal must include leakage, pressure drop, maximum velocity and maximum pressure data based on AMCA Publication 500. Dampers shall be in all respects equivalent to Ruskin Model CD36. Specifier Select Option Dampers shall be equipped with factory installed damper position indication switch package. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper blade position. The switch package shall provide the capability to interface with the HVAC control system and provide remote damper blade position status. Switch packages shall be in all respects equivalent to Ruskin Model SP-100. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0026 DATE: 03/10/15 PROJECT NAME: MICROSOFT SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ''JH' Building Division ig Public Works rvvi AP 3 « 1t Fire Prevention Structural n Planning Division Permit Coordinator n PRELIMINARY REVIEW: DATE: 03/12/15 Not Applicable n Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/09/15 Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MCKINSTRY CO LLC Hone Inicio en E piinnol Contact Page 1 of 4 Search L&I A-Z Index Hell, My Secure 1 I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries MCKINSTRY CO LLC Owner or tradesperson ALLEN, DEAN CHARLES Principals ALLEN, DEAN CHARLES, PARTNER/MEMBER MOORE, DOUGLAS JAMES, PARTNER/MEMBER ALLEN, DAVID EDWARD, PARTNER/MEMBER TEPLICKY, JOSEPH WILLIAM, PARTNER/MEMBER PEDERSEN, JAMIE D, AGENT Doing business as MCKINSTRY CO LLC WA UBI No. 602 569 922 PO BOX 24567 SEATTLE, WA98134 206-762-3311 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MCKINCL942DW Effective — expiration 03/16/2006— 03/16/2016 Bond ................ WESTERN SURETY CO Bond account no. 929511574 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 09/02/2010 09/09/2010 Expiration date Until Canceled Bond history Insurance ............................ Travelers Indemnity Company Th $2,000,000.00 Policy no. VTC2KCO5643B901IND14 Received by L&I Effective date 12/01/2014 01/31/2014 Expiration date 01/31/2016 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602569922&LIC=MCKINCL942DW&SAW= 3/25/2015 MCKINSTRY CO LLC Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........................................................ No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Self Insured. 706,165-00 This business is certified to cover its own workers' comp costs. No premiums due. Doing business as MCKINSTRY CO Estimated workers reported N/A L&I account representative (360)902-4817 Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Citation issue date 09/10/2014 Inspection no. 317420271 Location 16106 E. Indiana Spokane, WA 99216 Citation issue date 02/11/2014 Inspection no. 316962778 Location 801 E. Wheeler Road Moses Lake, WA 98837 Citation issue date 02/06/2014 Inspection no. 316960889 Location 7761 Randolph Rd Moses Lake, WA 98837 Citation issue date 12/14/2012 Inspection no. 316258235 Location 726 Broadway Ave Seattle, WA 98124 Violations No violations No violations Violations Page 2 of 4 Citation issue date No violations https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602569922&LIC=MCKINCL942DW&SAW= 3/25/2015