Permit M15-0029 - SKB MARKET READY - GAS UNIT HEATER AND EXHAUST VENT
SKB MARKET READY 606 INDUSTRY DR EXPIRED 11/02/15 M13-0029 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0223400010 Permit Number: 606 INDUSTRY DR Issue Date: Permit Expires On: SKB MARKET READY M 15-0029 5/6/2015 11/2/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: BLUE DOG PROPERTIES TRUST PO BOX 847 C/0 THOMSON REUTERS PTS, CARLSBAD, WA, 92018 INNA BUCKWALTER 1916 220 ST SE STE M101, BOTHELL, WA, 98021 PACIFIC AIR CONTROL INC 1916 220TH ST SE SUITE M101, BOTHELL, WA, 98021 License No: PACIFAC230P8 Lender: Name: Address: ,,, Phone: (206) 512-9647 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL GAS UNIT HEATER AND ROUTE EXHAUST VENT THROUGH ROOF Valuation of Work: $700.00 Type of Work: NEW Fuel type: GAS Fees Collected: $174.86 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Permit Center Authorized Signature: LOJL r 2014 2014 2014 2012 Date: C.'s_6'4 C I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit an agree to the conditions ttached to this permit. Signature: Print Name: /N/(/A i� tic.e.t),4 Date:LS—/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 18: All ceiling heat detectors within 25 feet of the heater should be replaced with high temperature heat detectors. 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. (,5- —g Project No. Date Application Accepted: 3 -).-k-f Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 022 3'/D0Dl DO / Site Address:60/2Q %1 ydlu Rive Tukw! LA WA- t� Suite Number: 0,614 Floor: / s7 Tenant Name: 5K U / PROPERTY OWNER Name: Ate_ PVP tg-n plove,,2 Ex cu1iv-e PaAk Address: g) 0 NW nis _ 1 1 s 5+ 3 0 cD City: P t-u�V1 GR State: CR Zip: 9 -7 CONTACT PERSON - person receiving all project communication Name: /,vi 8i�/CKi04_ /1 el `' Address: 19 lb 2:20f 'I1 &- - s+e M Ot City:B0_►T�pV1jl „ State: W f, Zip: sgozi Phone: 2O6-.s i 27%4-7 Fax: 206 _ 3 4O--2 7o Email: l '/VMA BP MOP l CA I k C D!vT 2I5Lt CCM New Tenant: ❑ Yes Z..No MECHANICAL CONTRACTOR INFORMATION Company Name: pat ice' lC Ana. . �.G�o / ti Address: 1g 16 2_20H, S/L- 4 'E i'fM e o/ City: B ► i e lL State: wA. Zip: 9802J Phone:204_68Z _6 393 Fax: 2Y_ 3g0-2270 Contr Reg No.: ?AC 1 FAC 23oP8 Exp Date: / pit /is �- Tukwila Business License No.: ELi _ 09 95-D 9 % Valuation of project (contractor's bid price): $ 70 0 Describe the scope of work in detail: I n S+CL...L_ .gas u n r+ h.ea+eR A-A/b RoW e Ex/1»-usf verd Use: Residential: New ❑ Replacement ❑ Commercial: New [ Replacement ❑ Fuel Type: Electric ❑ Gas 0 Other: /Z'e H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu I` Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTHORIZED AGENT: Signature: Print Name: /N/V4 13Gl C i.l'(JA L-[' Mailing Address: Date: L 'J 7//S Day Telephone: 2106 "-/2 -,9to 1-7 7 l.9)I Z201-6 S+ MI®1 &i LL WA 51e02-j City State Zip H:\Applications\Forms-Applications On Line \2011 Applications'Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $332.13 EL15-0268 Address: 606 INDUSTRY DR Apn: 0223400010 $72.77 ELECTRICAL $69.30 PERMIT FEE MULTI-FAM/COMM I R000.322.101.00.00 0.00 $69.30 TECHNOLOGY FEE $3.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.47 M15-0029 Address: 606 INDUSTRY DR Apn: 0223400010 $174.86 MECHANICAL $168.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $102.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $33.63 TECHNOLOGY FEE $6.73 TECHNOLOGY FEE R000.322.900.04.00 0.00 $6.73 PG15-0040 Address: 606 INDUSTRY DR Apn: 0223400010 $84.50 GAS $81.25 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $16.25 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4889 R000.322.900.04.00 0.00 $3.25 $332.13 Date Paid: Tuesday, March 24, 2015 Paid By: INNA BUCKWALTER Pay Method: CREDIT CARD 085216 Printed: Tuesday, March 24, 2015 1:53 PM 1 of 1 CRWSYSTEMS 2012 Washin•ton S; to Ener• Code Com•Iiance Forms for Commercial Grou• R1 and > 3 sto R2 and R3 fiance Forms for Commercial, Group R1, and > 3 sto Revised June 2013 2012 Washington Staterfer Proje m0� .�v� Q‘,\ly`r� ik G GO ,4,0 GGG �Q�� � ,1o1-J �� P .`a ,► Vp`iiu�ant �,�� l� �,��� Project Address /_ /n d� po tee %Lr t iii (C�7 /� Date 3//4/U For Building Dept. Use f88 A !leant Name: /�N��� is „, ,� 1 1 5,542 Applicant Address:/C�// 220/4K-GV 5.55E N/D� ��// {o L✓� �j Phone: �-- Boa-�z-g6�� Project D scri` `it� v Briefly describe eta .- system type and f legs. FA Includes Plans /�sLL /7P,e.�!%� , 06ka.Gt.I V I I/'� �i Include documentation requiring compliance J�LC�/�? tr'�%�1��,c��1 �i� �2d�e- L� `"� �y iG�0> '. p {� �g ' ' LXLIE COPY with commisegin.+.rovisiions�ppet"S eect1en'G4®8. Compliance Option %.imple System complex System plo.(ystems Analysis t : w ..,•' '...-.'• *- -- Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery YIN Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency' Heat Recovery Y/N LIM Wri R-Qat/ ok J)n -P-30 301)0P WA. moo 2V6cV S2 A/ he cik Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service Service Water Heating Equipment Schedule Equip. ID IDorn Equipy Type Brand Name' Model No.' Input Capacity Sub- Category EF7 EF' �"} �KWyILa MAR 7 4 2015 PERMIT CENTER 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per Simple Systems C403.3.1 or Complex Systems C403.4.1. 7 Efficiency Factor per Table C404.2. Mechanical 2012 Washington State Energy Permit Plans Checklist - Page 1 of 3 Group R1, and > 3 story R2 & R3 MECH-CHK Code CompliancepForms for Commercial, Revised June 2013 Project Address / Ob j n ,�/, uc ,{� ! „ r v /f '-T1 vi / r+ .4 b /9- Q e—g Date 3,J/6//5 The following information is necessary to check a hanical permitapplicationfor commercial provisionVlcompliance77Jwith the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance N h C403.2.1 Load calculations Load calculations performed perASHRAE Std 183 or equivalent per Chapter 3 y,e6 C403.2.2 Equipment and system sizing Output capacityof heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken yyt ,'/ �- C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC VI S 7 C403.2.3 & C403.2.3.2 & C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment %�—1 pi Ar C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. y,,es C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) /► .� / NI At r & C403.2. C403.10.32.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. C403.2.3 Maximum air cooled chiller capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit A/A C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non - standard operational conditions A/A- C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fans) meet efficiency requirements for axial fan open circuit cooling towers y495 C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss %9'"-/ AM, C403.2.3.3 Packaged electric heating/cooling equipment List equipment required to be heat pumps on schedule V !Y C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria ii,systems C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter Ai A C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lockout temp WAC403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling NC403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override A/A C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions l Y C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and retum air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions taken) /t A. �/ C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls V A, C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions A,Q 1 C403.2.4.6 Combustionquipment heating e Indicate modulating or staged control NAC403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum /) /�/` v �^s C403.2.4.8 / 9 Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken N4C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially occupied /I /'/j, V C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loadingdock and enclosed parking p g garage ventilation system activation and control method ArA, C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method /� /� V fT C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or altemative method taken (VAV, semi -conditioned makeup, or GERM calculation) #,J, C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions /VA, C403.2.6.2 Energy recovery -condensate systems Indicate on -site steam heating systems requiring energy recovery ArA— C403.2.6.3 Energy recovery -condenser systems Indicate remote refrig. condensers requiring ER and use of captured energy M'chanical Permit Plans Checklist - Page 2 of 3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3 Date ' MECH-CHK Revised June 2013 J p4,1is Project Address tr p 14 n ams72 / / o ? 1 v- 7 uik � I 1 vli <y ml The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH•CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) C403.2.12.1 Variable flow control -cooling towers Indicate cooling tower fans requiring variable flow control and method WA, C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken iv A. C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh l V A C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and demand response setpoint adjustment Ducting Systems C403.2.7.1 & C403.2.7.3 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements/ y..e g C403.2.7.3.1-3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans ,.-/ A/ A C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed ' V TJ C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork Piping Systems N4 C403.2.8 Piping insulation Indicate R-value of insulation on piping WAr C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems W A C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling A �" C403.3 Qualifying 2-pipe heating systems Verify2-pipe heating -only system does not exceed capacity limits g y y p ty NA C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers NA-, C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. NAC403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception / Y As C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) Ai A, C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh A% A. C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) COMPLEX SYSTEMS Complex System Economizers N/4, C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. A / �i iV j7 C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation N� C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems A i /T Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA �A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit Wit C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) echanical Permit Plans Checklist - Page 3 of 3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3 MECH-CHK Revised June 2013 P Project Address /' Ob J "Ji / /di 'jrL� J l�.Q / `/,e 7 1,0 / { ,4- %/4 9f Js/� [acJmechanical Date 3 //6/ jS The following information is necessary ttoo}check permit applicationapfor commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements NA,v A C403.4.2 C403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch MA C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure PVzones A C403.4.5 VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken &A C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads i v i y AMQ C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons � / A ° C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method t/ A_ C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh WAG403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N A 0403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use iv A C403. C403.4. 4.23.6 & Variable flow control - pumps Indicate pumps requiring variable flow control & method NA C4 & 03.2.12.1C403.4.4 Variabletowers flow control -cooling Indicate cooling tower fans requiring variable flow control and method IV C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by z 50% for systems > 300,000 btuh A /A V C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range NA. C403.4.3.3.1 deadbandWater loop heat pump - Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes MA C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 NI C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp %A v C403.4.6 Condenser water heat recovery Indicate system provided to pre -heat service water and efficiency I11 C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters Atifi- C403.5 / 6 Cooler / freezer -evaporator and condenser fans _ Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems A/A-. C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) ' VA C404.3 Temperature controls Indicate temperature controls have required setpoint capability NA, C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge / V C404.5 Insulation under water heater Indicate R-10 insulation under tank C404 6 Service water piping insulation Indicate R-value of insulation on piping; note exceptions taken N11 J�] C404 7 / 8 trace shut-off Circulation systems and heat Indicate shut-off capability based on occupancy and periods of limited demand %v A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas Q iv C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters a 4 COP AfAs C404.10.1 / 2 Pool heater on /off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or exception taken ArA, C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required / V 4 C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F 947, C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use Model UDAP tx 0 DESCRIPTION STANDARD FEATURES RECEIVED CGS', OF TUKWILA vfR242015 PERMIT CENTER OPTIONAL FEATURES - FACTORY INSTALLED Page Number Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters ODZ COMPLIANCE P►PR 28 2015 CSA 2.6b oc T6 ukW lts NG DMi&O4` of Sizes 30-125 carry an additional approval -for-use.in residential garage/workshops under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada ANSI Z83.8b eznor® V3 Series Model UDAP gas -fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. All sizes are approved for commercial/industrial installations. Sizes 30-125 carry an additional approval for use in attached residential garage/workshop application. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the TcoRE2 heat exchanger and single burner combustion system. Other standard features include a single -stage gas valve, multi -try direct spark ignition with timed lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency, easier installation, and a new look - both inside and out. Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled corner to know you have a genuine Reznor heater. • Sizes 30-400 certified for commercial/industrial heating application • Sizes 30-125 carry an additional approval for use in residential garage/workshop heating applications • 82-83% Thermal efficient - TOP in its class! • 50-60°F Rise range • TCORE2 titanium stabilized aluminized steel heat exchanger • Patented " single burner combustion system including a one-piece burner assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload protection • Transformer for 24-volt controls • Integrated circuit board with diagnostic indicator lights • Multi -try direct spark ignition with timed lockout • Fan relay (included on the circuit board) • Single -stage natural gas valve (field adjustable for operation to 9,000 ft. elevation m) • Vibration/noise isolated fan and venter motors - designed for low noise operation • 2-pt and 4-pt Suspension - standard on all sizes • External terminal strip for 24-volt wiring • External gas connection • Full fan guard - engineered for safety • Improved cabinet design with less visible hardware • Single -stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation e) • Two -stage natural gas or propane gas valve - Sizes 60-400 • 409 or 316 Stainless steel heat exchangers • Totally enclosed fan motor (Sizes 30-250, 115V only) • Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) " U.S. Patent No. 6,889,686. e Pressure switch change required for installations above 6,000 ft. Form RZ-C-UH (Version H) Page 8 Page Number of OPTIONAL FEATURES - FIELD INSTALLED TECHNICAL DATA Model UDAP • Vent cap • Thermostat • Thermostat guard with locking cover • Vertical louvers • Downturn nozzle kits • Gas conversion kits (natural and propane) • Primary/secondary controls for zoning up to six units • Ceiling suspension kit - Sizes 30-125 • Hanger kits for 1" pipe • Stepdown transformer (for 208/115, 230/115 or 460/115 supply voltage) • Manual shutoff valves Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400 Input Heating Capacity BUH T 30,000 45,000 60,000 75,000 105,000 120,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 8.8 13.2 17.6 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency (%) 82 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Heating Capacity c BTUH 24,600 37,350 49,800 62,250 87,150 99,600 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 kw/h 7.2 11.0 14.6 18.3 25.6 29.2 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection (inches) ° Natural 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size E (inches diameter) 4 4 4 4 4 4 5 5 5 5 5 6 6 6 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection F 15 15 15 15 15 15 15 15 15 15 15 20(1 20 20 Normal Power Consumption (watts) 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise ('F) 50 55 60 60 60 60 60 60 60 60 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 M3/minute 12.9 17.8 21.8 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening Area ft2 0.96 0.96 1.25 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 M2 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 Fan Motor HP ° - Open 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Enclosed 0.06 0.06 0.06 0.06 1/20 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1550 1550 1550 1550 1050 _1/20 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter (inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dba @ ft 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net Weight Ibs 54 59 67 72 96 101 172 187 187 203 215 269 294 306 kg 24 27 30 33 44 46 78 85 85 92 98 122 133 139 Approximate Ship Weight Ibs 61 66 74 79 118 123 204 219 219 245 257 321 346 358 kg 27 30 33 36 54 56 93 100 100 111 117 146 157 163 c GSA rating for altitudes to 2000 ft. ° Size shown is for gas connection to a single stage gas valve, not supply line size. e Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I-V-PV. If vent diameter is different from vent connection, reducer/enlargers will be field -required. F MOP = 2.25 x largest motor FLA + remaining load. Answer is rounded down to the next size of commercially available circuit breaker or fuse. ° All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. For installations where dirt dust, and other air borne contamination Is present In the Indoor environment, It Is recommended to use separated combustion units (Model UDAS). These models use air from outside the space for combustion. This will help reduce the build up of contaminates on the burner which would affect the combus- tion process. Refer to the Installation manuals for recommended frequency of maintenance and cleaning. Form RZ-C-UH (Version H) Page 9 DIMENSIONS Model UDAP ±1/16" (2mm) Page Number of Size A B C D E F G H J K M N P Q R 30, 45 12 1/8 25 5/8 10 13 13/16 26 21 9/16 5 3/16 6 1/2 2 11/16 3 7/8 17 3/8 11/16 4 5/16 13 9 9/16 60 15 1/8 25 5/8 13 13 13/16 27 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 75 15 1/8 25 5/8 13 13 13/16 27 5/8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 100 23 1/8 25 5/8 21 13 13/16 28 5/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 125 23 1/8 25 5/8 21 13 13/16 29 3/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 150, 175, 200 20 1/8 38 3/16 16 23 42 35 3/8 8 1/2 8 1/4 5 7/16 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 16 3/8 225, 250 26 1/8 38 3/16 22 23 42 35 3/8 13 1/16 8 13/16 9 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 15 5/8 300, 350, 400 34 1/8 41 30 23 42 35 3/8 17 1/16 9 11 13/16 7 5/16 27 11/16 1 3/8 8 3/16 22 3/16 16 3/16 Size A B C D E F G H J K M N P Q R 30, 45 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (243) 60 (384) (651) (330) (351) (686) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 75 (384) (651) (330) (351) (702) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 100 (587) (651) (533) (351) (727) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 125 (587) (651) (533) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 150,175' 200 (511) (970) (406 ) (584) (1,067 ) (899) (216) (210) (138) (165) (652) (35) (208) (564) (416) 225,250 (664) (970) (559) (584) (1,067) (899) (332) (224) (229) (165) (652) (35) (208) (564) (397) 300, 350, 400 (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208)(564) (411 ) P and Q - Hanger Dimensions for 4-pt Suspension TOP VIEW R - Hanger Dimension for 2-pt Suspension 1 f3/8"-16 Female Thread I I - all suspension points _i_ t B D T0/,-���1 A C REZNOR .,_ FRONT `s , . VIEW It _- i. ♦ ETORE2 CLEARANCES FROM COMBUSTIBLES Thermostat Connection (30-125 Vertical; 150-400 Horizontal) l� Line Voltage Inlet (connects at circuit board) Combustion Air Inlet 4- K 4--- H External Gas Connection F Vent Connection (see Technical Data for size) RIGHT SIDE VIEW (Access Panel) Size Top Flue Connector Access Panel' Non -Access Side Bottom " Rear L inches mm inches mm inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 " Access Panel clearance is required for service clearance to controls " Suspend the hea er so that the bottom is a minimum of 5' (1.5M) above the floor. Rear clearance is required for air movement. Rear clearance should be measured from the fan motor. Form RZ-C-UH (Version H) Page 10 City of Tukwila Department of Community Development 10/1/2015 INNA BUCKWALTER 1916 220 ST SE STE M 101 BOTHELL, WA 98021 RE: Permit No. M 15-0029 SKB MARKET READY 606 INDUSTRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/2/2015. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/2/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley2 Permit Technician File No: M15-0029 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0029 PROJECT NAME: SKB MARKET READY SITE ADDRESS: 606 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # DATE: 03/24/15 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division um Public Works Fire Prevention Structural Planning Division Permit Coordinator n ■ PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/26/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/23/15 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PACIFIC AIR CONTROL INC Page 1 of 2 Home lnicio en Espanol Contact Search L&I 13`J A-Z Index Help My Secure I.'zl Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries PACIFIC AIR CONTROL INC Owner or tradesperson RUTTAN, GARY JAMES Principals RUTTAN, GARY JAMES, PRESIDENT CRAWFORD, LARRY C, SECRETARY (End: 10/05/2011) Doing business as PACIFIC AIR CONTROL INC WA UBI No. 601 298 907 1916 220TH ST SE STE 101 BOTHELL, WA98021-8427 206-682-6393 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. PACIFAC230P8 Effective — expiration 10/28/1977-10/01/2015 Bond ................. TRAVELERS CAS & SURETY Bond account no. 104920215 $6,000.00 Received by L&I Effective date 05/09/2007 05/26/2007 Expiration date Until Canceled Insurance .............................. PHOENIX INSURANCE COMPANY THE $1,000,000.00 Policy no. 4TC07314N491PHX09 Received by L&I Effective date 06/17/2014 07/01/2010 Expiration date 07/01/2015 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601298907&LIC=PACIFAC230P8&SAW= 5/6/2015 HVAC GENERAL NOTES 1. VERIFY SITE CONDITIONS. 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC. 3. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. 4. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. 5. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. 6. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT", 2012. 7. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED PER LOCAL CODE. 8. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN. 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS -BUILT DRAWING. 10. COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OF OCCUPANCY, PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCE WITH THE PROVISIONS OF SECTION C408 OF THE 2012 WSEC 11. WALK-THRU INSTRUCTION: PROVIDE ON SITE WALK-THRU FOR CUSTOMER TO DEMONSTRATE OPERATION OF SYSTEM AND ANSWER QUESTIONS. 12. ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE FACTORY ROOF CURB FOR NOISE CONTROL. 13. GAS PIPE: SCHEDULE 40, BLACK STEEL. PAINT PIPE EXPOSED TO WEATHER. 14. SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM. 15. PIPE HANGERS: SWIVEL LOOP STYLE, MICHIGAN NO.100 OR CLEVIS STYLE, NO.400 OR EQUAL BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS. 16. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES (2012 IMC SECTION 301.10). LINE VOLTAGE WORK BY OTHERS. DUCT NOTES 1. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE 2012 IMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS NOTED. 2. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF DIFFUSERS. 3. DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALL BE INSULATED TO MINIMUM OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.7 OF 2012 WSEC. 4. DUCT SEALING -GENERAL: 0 TO 2" STATIC PRESSURE - SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS. ABOVE 2"-SEAL SEAMS, JOINTS AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS-181" GRAY OR APPROVED EQUAL PER UL 181 A-M, 181B-M LISTED. OUTSIDE: POLYURETHANE, MAMECO VULKEM 116. OR APPROVED EQUAL. 5. TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER SMACNA STANDARD. 6. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED. 7. SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA. 8. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK-UPS TO ISOLATE AIR HANDLING EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) 9. DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR RECTANGULAR DUCTS THAT ARE NOT LINED. PROVIDE CIRCULAR EQUIVALENT OF RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE SUBSTITUTED TO BETTER FIT SPACE. 10. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL OPENINGS. NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A UNIT HEATER SCHEDULE UNIT NO. SERVICE & LOCATION MANUFACTURER & MODEL NO. HEATING, MB AFUE BLOWER ELECTRICAL WT/ INPUT OUTPUT CFM RPM HP VOLT/PH APM LBS UH-1 BLDG 4, STE 606A REZNOR V3 SERIES UDAP-30 30 24.6 82 '456 1550 0.06 115V/1 1.9 54 NOTES: 1. EQUIPMENT SIZING PER WA ENERGY CODE 2012 C202 (SEMI -HEATED SPACE). 2. UNIT HEATER PROVIDED WITH INTERMITTENT IGNITION. 3. UNIT HEATER IS SERVED FOR FREEZE PROTECTION AND PROVIDED WITH LOCKABLE THERMOSTAT. LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARK #5 LESS UP RR OPER R/W TAX PARCEL NUMBER: 022340-0010 NCWP ANDOVER EXECUTIVE PARK BUILDING 4 SITE PLAN SCALE: 1 "=30'-0" SYMBOL ABBREV. Zi i � s 111 z -I N-- SEPARATE r"L:;.! i^J T REQUIRED FOR: 0 Mechanical t Electrical Plumbing Gas Piping City of Tukwila C:i ,if i.Y: !;:4 DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PARCEL: 022340-0010NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A Fria ©. f 16 D Plan review approval is subject to errors and omissions, Approval of construction documents does not authorize the violation of any adopted cod© or ordinance. Receipt of approved Field Copy ei conditions is w Qc fJ i; By: Date: City cfTukwila BUILDING DIVISION SL VD FC TV EC SD MG RG EG TG 1-27 AFF LEGEND & ABBREVIATIONS DESCRIPTION SUPPLY DUCT RETURN/EXHAUST DUCT SOUNDLINED DUCT MANUAL VOLUME DAMPER FLEX CONNECTOR TURNING VANES END CAP SUPPLY DIFFUSER, CEILING MAKEUP GRILLE RETURN GRILLE, CEILING EXHAUST GRILLE, CEILING TRANSFER GRILLE, CEILING SIDEWALL SUPPLY/MAKEUP SIDEWALL RETURN/EXHAUST EQUIPMENT TAG ABOVE FINISHED FLOOR BD, BDD BACKDRAFT DAMPER BS DN EA BIRDSCREEN DOWN EXHAUST AIR OA, OSA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR (N) NEW (E)/EXIST EXISTING (R) RELOCATED BWG TWG TYP VD BOTTOM WALL GRILLE TOP WALL GRILLE TYPICAL VOLUME DAMPER DEMO REVISIONS AIR TERMINAL LEGEND GRILLE, REGISTER, DIFFUSER IN LEGEND ARROWS INDICATE AIR NO ARROWS INDICATE SYMBOL ABBREV. DESCRIPTION e FIRE DAMPERED DUCT PENETRATION OF A HORIZONTAL SEPARATION V FIRE DAMPERED DUCT PENETRATION OF A VERTICAL SEPARATION m TIMER 0-4 HR ADJUSTABLE THERMOSTAT/HVAC UNIT # SENSOR/HVAC UNIT # SENSOR (CEILING MOUNT) CI EXHAUST FAN o PIPE/DUCT UP PIPE/DUCT DOWN PIPE TEE DOWN o PIPE TEE UP EXIST DUCTWORK, EQUIP NEW DUCTWORK, EQUIP ADJ ADJACENT BSC BIOLOGICAL SAFETY CABINET CFH CHEMICAL FUME HOOD CFM CUBIC FEET PER MINUTE DB DUCT BOARD L,S LIQUID, SUCTION N NECK NIC NOT IN CONTRACT OAI OUTSIDE AIR INTAKE RD ROUND DIFFUSER SHC SENSIBLE HEATING CAPACITY SR SUPPLY REGISTER TC TOTAL COOLING VEL VELOCITY WH WATER HEATER NOV.02 2 5 XX 8x8 -- NECK SIZE (INCu•f }.,.,-R.,,.... 140 SQUARE OR RECTANGULAR AIR QUANTITY (CFM) XX 8"0 NECK SIZE (INCHES) 140 ROUND Air Quantity (CFM) PATTERN FOR CEILING DIFFUSERS FOUR WAY PATTERN FIRE SPRINKLER HEADS TO BE FAST REACTION TYPE BY OTHERS. DESCRIPTION OF WORK: 1. INSTALL (1) NEW GAS UNIT HEATER AS SHOWN ON PLAN. INSTALL NEW EXHAUST VENT THROUGH ROOF. 2. ROUTE NEW GAS PIPING SERVING UH-1 TO NEW METER (BY OTHERS). REV;EWED FOR CODE COMPLIANCE APPROVED APR 2 8 2015 Cit4 of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 4 2015 PERMIT CENTER DRAWING INDEX M-1 LEGEND & ABBREVIATIONS, VICINITY MAP, NOTES, SITE PLAN AND EQUIPMENT SCHEDULE M-2 ANDOVER BUSINESS PARK, BLDG 4, STE 606A - PARTIAL HVAC & GAS PIPING PLAN Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 www. pacificaircontrol.com _ In 44( to (0 LU co 0 al W co co Ce Ck= co E n (-) g X to W Ce Cl.40( DATE 03/05/15 DESCRIPTION PERMIT ISSUE A A A n A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER GL DESIGNED BY IB DRAWN BY IB CHECKED BY GL SCALE AS NOTED PROJECT NO. T150305 DRAWING TITLES LEGEND & ABBREVIATIONS VICINITY MAP, NOTES, EQUIPMENT SCHEDULES & SHEET INDEX SHEET NUMBER ¥115OO.Z? Mm1 FILEPATH: I:\Construction\Autocad Flles\Autocad\IProJecta\ANDOVER EXECUTIVE PARK\Andover Executive Park 606 Industry Drive 1 of 2 COPYRIGHT 0,2001 PACIFIC AIR CONTROL, INC. N ► Pand 0-� Hanger p Dimensions for 4-pt - Suspension (4-pt is required if installing optional Q nozzle.) 1 3/8"-16 Female Thread - all suspension points M and N - Hanger Dimensions for both 2-pt and 4-pt Suspension R - Hanger Dimension for 2-pi Suspension Thermostat Connection (30-125 Vertical; 150-400 Horizontal) Line Voltage Inlet (connects at circuit board) 1.1/4 —. (32) E Combustion Air Inlet • K 4- H INSTALL NEW GAS METER (BY OTHERS) TO SERVE UH-1 IN STE 606A WHSE SPACE ; PRESSURE INLET — LESS THAN 2 PSI PRESSURE DROP — 0.5 W.C. SPECIFIC GRAVITY— 0.5 ROUTE (N) 3/4"0 GAS LINE (20' L) FROM (N) GAS METER TO UH-1 (30 MB INPUT) SECURELY SUPPORT NEW GAS LINE FROM BUILDING STRUCTURE PER IFGC 2012 407 REQUIREMENTS; CONNECT NEW GAS LINE TO UH-1; INSTALL SHUT—OFF VALVE AND DRIP LEG PER IFGC 2012 409 REQUIREMENTS UH-1 INSTALL THE UNIT HEATER IN ACCORDANCE WITH LOCAL BUILDING CODE, NFGC 2012, ANSI Z223.1 & MANUFACTURER REQ'S. SUSPEND THE UNIT 4' FROM ROOF FRAMING STRUCTURE WITH 3/8" THREADED RODS FROM THE THREADED NUT RETAINERS AND BRACE FROM BOTH HORIZONTAL DIRECTIONS 'N (2—POINT SUSPENSION). External Vent Collar (For Gas size, see Technical Connection Data in the APPENDIX on page 38.) F RIGHT SIDE VIEW (Access Panel) Model UDAP Dimensions ('aches +_ 1(16) Size 30, 43 A R C D 12-1/8 26-5/8 10 13-13/16 26 21-9/1665-3/16 6-1 t2 2-11 /16 3-7/8 17-3/8 l 11116 4.5116 6 EK F G H J UNIT UH-1 DETAIL NTS M N P Q R 13 9-9/1 RR RR RR RR OPEN AREA WAREHOUSE AREA 1510 SF NEW 4"0 UNIT HEATER COMBUSTION AIR EXHAUST, VENT THROUGH ROOF PROVIDE LOCKABLE THERMOSTAT AT UNIT HEATER HEIGHT ELEVATION FOR FREEZE PROTECTION r WAREHOUSE AREA OFFICE OFFICE i RR WAREHOUSE AREA RR OPEN AREA OPEN AREA 1 606 INDUSTRY DRIVE, STE 606A OFFICE 606 INDUSTRY DRIVE, " 606 INDUSTRY DRIVE, STE 606B STE 606C NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A - PARTIAL HVAC & GAS PIPING PLAN SCALE: 1/4" = 1' - 0" AREA OF WORK NVII 115 02 2 ae� � REVEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2015 City of Tukwila BUILDING DIVISION LJ LMEM STE 606A NCWP ANDOVER EXECUTIVE. PARK BUILDING 4 KEY PLAN NTS RECEIVED CITY OF TUKWILA MAR 2 4 2015 PERMIT CENTER Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 www.pacificaircontrol.com 0 Li. W 0 PROPOSED NO. DATE DESCRIPTION n 03/05/15 PERMIT ISSUE A A A A A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER DESIGNED BY GL IB DRAWN BY IB CHECKED BY GL SCALE PROJECT NO. AS NOTED T150305 DRAWING TITLES NCWP ANDOVER EXECUTIVE PARK BLDG 4, STE 606A — PARTIAL HVAC PLAN SHEET NUMBER 2 of 2 FILEPATH: 1:\Conetructton\Autocad Fllee\Autocad\IProjecte\ANDOVER EXECUTIVE PARK\Andover Executive Park 606 Industry Drive COPYRIGHT ©2001 PACIFIC AIR CONTROL, INC.