Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0030 - 4501 BUILDING - ROOFTOP UNITS, HEATERS, EXHAUST FANS ETC
4501 BUILDING 4501 S 134 PL M15-0030 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2613200045 Permit Number: M15-0030 4501 S 134TH PL 4501 BUILDING Issue Date: 4/7/2015 Permit Expires On: 10/4/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SMITH COURT LLC PO BOX 146 , RENTON, WA, 98057 ALEX BURKHART 727 S KENYON ST, SEATTLE, WA, 98108 EVERGREEN REFRIGERATION LLC 727 S KENYON ST, SEATTLE, WA, 98108 EVERGRL954R2 Phone: (206) 763-1744 Phone: (206) 763-1744 Expiration Date: 1/6/2016 DESCRIPTION OF WORK: INSTALLATION OF 2 ROOFTOP UNITS, 2 UNIT HEATERS, 4 EXHAUST FANS, DUCT WORK, AND GRILLES/DIFFUSERS. Valuation of Work: $0.00 Type of Work: NEW Fuel type: GAS Fees Collected: $520.26 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature/I 7 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. U" Signature: �""�1"—n Date: I / 115 l Print Name: / t)Lt / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2013 edition). 1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 2: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 5: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 7: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 8: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 9: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***MECHANICAL PERMIT CONDITIONS*** 15: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 16: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0609 0705 0701 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUICW„Ldi Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. t\ 1\ S" Project No. r� _ Date Application Accepted: Date Application Expires: g i a t i l 5 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 050 I 5. I3 ` t P Tenant Name: PROPERTY OWNER Name: 51,11 i AC'i CAA- L� , Address: vo v 11_16 City: Revykryin State: oW/ Zip: a t 0 5-1 CONTACT PERSON - person receiving all project communication Name:/fin v, n uv Address:` -vb.-1 5,v.N,1 I 8.0„, SA- , City: stAittle,State: i/is- Zip: Tan Phone: 206=14.3- rLti`4. Fax: 2,06 --/c3 -23tei Email: 41e)i‘,,,e evn,,.c¢,v,,kv-i-c.-Gow. King Co Assessor's Tax No.: Zoo 13 Zova 4 5 Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: � tt I k]-► ,3c r'i'' 't JIB, Address: 721 5r,A4, ke.„, , S City: - State: kA4),,_. Zip: ci 4 ig Phone: 7,6G _-16} - 11q'4 Fax: 2pGG - 1t 3 - ri l Contr Reg No.:.uL R614, Li stf xp Date: ( 16 / V- Tukwila Business License No.: Bus _ O 6l e( z 77 Valuation of project (contractor's bid price): $ ' "1%66 -It' Describe the scope of work in detail: ��> , CZ) �� l•cR.k'er� �� ��\ �� I-►'►� � L� <-}-� (Z) rw c - u �� J Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement Gas [,]' Other: H:Wpplications Forms -Applications Ou Line ,2011 Applicatious\Mechanical Permit Application Revised 8.9.11.docx Revised: Aueus12011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater 2 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 2 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 4 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser i Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: / Signature: A/' Date: / 1/5 ( Print Name:Atill" Day Telephone: 2i l,3 _ Illy Mailing Address: 12:7 sow LanAph Sk. City State Zip H:\Applications\Forins-Applications On Line \201 I Applcations\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bit Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $724.30 EL15-0270 Address: 4501 S 134TH PL Apn: 2613200045 $77.28 ELECTRICAL $73.60 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $73.60 TECHNOLOGY FEE $3.68 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.68 M15-0030 Address: 4501 S 134TH PL Apn: 2613200045 $520.26 MECHANICAL $500.25 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $367.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $100.05 TECHNOLOGY FEE $20.01 TECHNOLOGY FEE R000.322.900.04.00 0.00 $20.01 PG15-0042 Address: 4501 S 134TH PL Apn: 2613200045 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4896 R000.322.900.04.00 0.00 $4.88 $724.30 Date Paid: Wednesday, March 25, 2015 Paid By: EVERGREEN REFRIGERATION Pay Method: CHECK 7054 Printed: Wednesday, March 25, 2015 10:02 AM 1 of 1 rmSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ifQ)) i3a5 Type of In potion: e A --;:--it-44--( Address: '/SQ/ q /30 PI Date Called: l iP-- Special Instructions: AJ_ Date Wanted: Requester: yA-A) Phone No: 2eVX"7�i /35 pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: ector: Date. 2f/6- e REINSPECTION FEE REQUIRED. Prior to next inspection, f must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. insp V L--49224d44-- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 41/5 ,30 Project; , , tiiCt i 4C/itil KV/ Type of Inspec on: Ofiik'CA /&,.0..-W- �i 17 5/ i S /341Address: j �� , Date Called: IIP- Specialq Instructions: �L( Date Wanted: / ///T am p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Nam" /*roue" i(,av D:c IL) rk Inspector: Date: i ir-3/1/5 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 AUS---0030 Pr t: Ppa 0 ( 4 ( Type of Insp ction: f2 o '? ` --(4 At G'1 A1(rS:i L' Date Calle'� Special Instructions. ittm 6, ` '�7i" _ \ �— t © c c_-+rr�t.t`c-1( Date Wanted: a.m. Re uester. Rev e a Gk Phone No: Approved per applicable codes. E J Corrections required prior to approval. OMMENTS: Inspector: Date: 1 ( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. C INSPECTION RECORD Retain a copy with permit IN PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 �I.r. 003o Project: / LI.Zt 6i3 Typ of Inspection: t t1/4----ik Aitg-cli Address A3—d 153, r311 pJeg-e- Date Cal: Special Instructions: /� ,�^ , l Date Wanted: -7— 04 a.m. P.m - Requester: %ncr4G+ Phone No: Z©6--677-3(13� Approved per applicable codes. Corrections required prior to approval. COMMENTS: 04- 4)1-EH - 6tkoi re-s-t-ir- 6- a. (AA_S Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MEOH-SUM Revised June 2013 Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Pr . )eD FOR RIIIITukwila, CODE COMPLIANCE APPROVED APR0 1 2015 • i)(75 X' V� Project Address 4501 S 134th P1. Date 3/17/2015 WA 98168 For Building Dept. Use Applicant Name: Alex Burkhart Applicant Address: 727 South Kenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744 ext. 247 Project Briefly6yfjiIVISION systenThrMleatures. Includes Ulivt T> iNila Installation of two (2) rooftop units, two (2) unit heaters, and four (4) exhaust fans. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Plans 0 Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception6 Heat Recovery Y/N RTU-1 Lennox ZGA03654B 35800 240 13 N/A Econmizer N RTU-2 Lennox ZGA036S4B 35800 240 13 N/A Econmizer N Heating Equipment Schedule Equip. ID Equip Type Brand Nam& Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N 1TU-1 Lennox ZGA036S4B 52000 240 65000 52000 80 N RTU-2 Lennox ZGA036S4B 52000 240 65000 52000 80 N UH-1 Reznor UDAP-45 37350 N/A 45000 37350 83 N UR-2 Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service EF-1 Broan QTR110 90 0.20 0.05 CV Ceiling EP-2 Broan QTR110 90 0.20 0.05 CV Ceiling EF-3 Broan QTR110 90 0.20 0.05 CV Ceiling EF-4 Broan QTR110 90 0.20 0.05 CV Ceiling Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category EF7 Location of Service 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 6 Flow contro pes: me (VAV), constant volume (CV), or variable speed (VSJ1 �iiil t exception number per atb.. r : CITY OF TUKlit/i`. _: Plan review a flr,,,z i Permit Mo. MAR 2 5 2r5 CNio 1T1ei1 DEDcnrT- tschrrnr1 r Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 4501 S 134th Pl. Date 3 / 17 /2 015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance Yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 M1 Yes C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken M1 Yes .. C40325 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC M1 Yes C403.2.3 & C403.2.3.2 &efficiency C403.2.12.1 Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment M1 N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. N/A C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) N/A C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. N/A C403.2.3 capacity Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced heatersair furnace and unit Indicate intermittent ignition or IID, flue/draft damper & jacket loss N/A C403.2.3.3 heating/cooling equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M1 Yes C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp M1 Yes C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling M1 Yes C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M1 Yes C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions M1 Yes C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M 1 Yes C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls M1 N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating i equ pment Indicate modulating or staged control N/A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A C403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Yes C403.2.5.1 ventilation Demand controlled Indicate high -occupancy spaces and systems requiring DCV M1 Yes C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or altemate means provided to automatically reduce OSA when partially M1 Yes C403.2.5.3 Enclosed loading dock/parkinggarage ventillationionsystem Indicate enclosed loading dock and enclosed parking garage ventilation activation and control method M1 N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) N/A C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions N/A C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery N/A C403.2.6.3 Energy recovery - condenser systems Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 for Commercial, Group R1, and> 3 story R2 and R3 2012 Washington State Energy Code Complianc MECH-CHK Revised June 2013 Project Address 4501 S 134th PI. Date 3/17/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N/A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) N/AInC403.2.12.1Var ltowerslow control cooling dicate cooling tower fans requiring variable flow control and method N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N /� / C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and demand response setooint adiustment Ducting Systems Yes C403.2.7.1 &Duct C403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements M1 N/A C403.2.7.3.1 ; Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans N/Atest C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Yes C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork M 1 Piping Systems N/A C403.2.8 Piping insulation Indicate R-value of insulation on piping N/A C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems Yes C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidification or simultaneous heating/cooling M1 N/A C403.3 systems Qualifying 2-pipe heating syst Verify 2-pipe heating -only system does not exceed capacity limits N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M 1 Yes C403.3.1.1.3 controls Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M1 Yes C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh M 1 Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) M 1 COMPLEX SYSTEMS Complex System Economizers Yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation M1 Yes C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems M 1 N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) Mechanical Permit Plans Checklist - Page 3 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 4501 S 134th PI. Date 3/17/2015 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A C403.4.2 2 c403.2.1 Variable flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N A / C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating bumer for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control pumps Indicate pumps requiring variable flow control & method N/A C403.2.12.1Variable & C403.4.403.4.4 flowcontrol cooling towers Indicate cooling tower fans requiring variable flow control and method N/A C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by >_ 50% for systems > 300,000 N/A C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/A C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes N/A C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A C403.4.6 recovery Condenser water heat Indicate system provided to pre -heat service water and efficiency N/A C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A C403.5 / 6 and condenser fans Cooler / freezer - evaporator Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Wa er Systems N/A C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A C404.5 water Insuheater Indicateunder Indicate R-10 insulation under tank N/A C404.6 Service water piping ii nsulaton Indicate R-value of insulation on piping; note exceptions taken N/A C404.7 / 8 Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas N/A C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters >_ 4 COP N/A C404.10.1 / 2 Pool heater on /off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use VISSER ENGINEERING ..,,"`- FILE COPY Permit Not n.r a re..l STRUCTURAL CALCULATIONS (HVAC Unit Support) Project: 4501 Building 4501 South 134th Place Tukwila, WA 98169 Project No.: 14-049 Client: Wayne Jones Lakeridge Development, Inc. PO Box 146 Renton, WA 98057 By: Date: RECEIVED CITY OF TUKWILA MAR 2 S '2015 PERMIT CENTER Andy Derrick, P.E., S.E. Mike Visser, P.E., S.E. March 23, 2015 REViEWEP FOR CODE COMPLIANCE APPROVED APR 01 2015 N5 City of Tukwila BUILDING DIVISION 1411‘ • oc331 HVAG UNIT BY OTHERS %" HEX HEAD 5D5T SCREWS @ 12"oc ALONG CURB - (4) SCREWS MIN. PER SIDE J MECHANICAL CURB BY OTHERS • 1/ L3x3x1/4 BTWN J015T5 - CUT VERT. LEG AT END AND WELD TO JOIST TOP CHORD JOIST PER PLAN VISSER ENGINEERING 32121 WEYERHAEUSER WAY 5. SUITE 103 FEDERAL WAY, WA.18001 VOICE: (253) 835-0810 FAX: (253) 835-0813 1 Rooftop HVAG Unit Support ELECTRONICALLY SIGNED HILTI 1/4-20 KWIK FLEX SCREWS @ 12 "oc FROM CURB TO L3x3 - (4) SCREWS MIN. PER SIDE lb 34. 11/2 21/2 JOIST PER PLAN L3x3x'4 PER PLAN TITLE Rooftop HVAG Unit Support PROJECT: 4501 Building 5. 134th Place Tukwila, WA MT: Lance Mueller Associates SCARE: 3/4 ": ('-O" 130 Lakeside Seattle, WA Beak ADD CAD: ADD PROD. O. 14-041 ISSUE DATE 03/23/15 T: 1 I CALCULATION SHEET VISSER ENGINEERING t z,42.."7:7: itNr 1,111.4; p - 10t3J Title: P.0 • Project: 45t:ii \ Client: Date: Page: i , , 1 , i -+. 4 i , ......_. 1 ‘ I <:` p 1,„4. q J.A.4 Z 10- 111/\4/. ) q2c-, L,--4 CT) • CALCULATION SHEET VISSER ENGINEERING . P. rqL.,( v • L 9 , fT\ W Cst - Title: 4c—C) Project: Client: Date: Page: (ou,s biL.Ttr-lciAL (2e-\, • ) )k,.* ) I r 9 f- '4,; F-UL.;;;: • k-'7.", ) CALCULATION SHEET VISSER e:414,0", ENGINEERING ,L'a'd • r Title: Project: Client: Date: Page: 'ANC, f„). 1„.( c-ss ( ••••-r ( 444 3 '1 14- C1. 1\14147-ET74.1-\.L. I ...... /' rf3,-- `r. 1, . , 1.•-i,„•.;: t e I . "•\ e4) C)C FLEX 7,) -7- ft(- = ALL' > Sf 114 s;. 3f — -.7-7.-- , - — CALCULATION SHEET VISSER %;•],l'ifs:".47, ENGINEERING • :14,;;;: ft:" 31411----1(7), OF Co') \?\ CDT 11/4'1, -42 -JCT. 4/ 2) j Title: Project: Client: stt, Date: Page: 4, t4',-) 4 ---1- .1.3"T° )i4SIC,c1.77 o N.( : . fikS.77-..„--qii,r•i(;,- "I' TZ,'Er ,i-,Ti4kt-L. u'i----_1 FT LUIt‘, .._ Lk.) LA,,, Tik 3c)i a-t-s f -zr 7'73 -- • . , • 1 vi Ll VISSER ENGINEERING Calculation Sheet Project: 4501 Building (14-049) Client: Jones Date: 03/21/15 Page: ,C., Title: Bending of Single Angle About Geometric Axes (Equal Leg) - No Lateral Torsional Restraint Section: L3x3x1/4 Is Angle -Leg Tip in Compression or Tension: T E = 29000000 psi b = 3 in t = 0.25 in I = 1.23 in Cb = 1.5 Fy = 36000 psi Sx = 0.569 ire 4b = 0.9 For Compression in Angle -Leg Tip Mob = 174912 lb -in My = 16387 lb -in Mn = 24581 lb -in M,ix = 6500 lb -in For Tension in Angle -Leg Tip Mob = 768735292 lb -in My = 16387 lb -in Mn = 24581 lb -in Check: M,tt/I)bM,x = 0.29 OK Screw Fasten:ny Systems Self -Drilling Screws 3.6.2 3.6.2.1 Product Description The Hilti Self -Drilling Screws are designed to drill their own hole in steel base materials up to 1/2" thick. These screws are available in a variety of head styles, thread lengths and drill -flute lengths for screw diameters #6 through 1/4". Hilti self -drilling screws meet ASTM C 1513, ASTM C 954 and SAE J78 standards, as applicable. Product Features • Hex head for metal -to -metal applications • Flush head for wood -to -metal applications • For metal from 0.035" to 0.500" thick • Winged reamers for wood over 1/2" thick • Stitch screws for Tight gauge metal -to -metal • Sealing screws for water resistant fastenings 3.6.2.2 Material Specifications Material ASTM A 510 Grade 1018-1022 Heat Treatment Case hardened and tempered • Sizes 8, 10 and 12: 0.004" to 0.009" case depth • Size 1/4": 0.005" to 0,011" case depth Plating • Wood decking screws: Black Phosphate (8-18 x 1-5/16" PFH #3 and 8-18 x 1-15/16" and 5/16" PFH #3) • Kwik-Cote and Kwik-Seal screws: 0.0007" to 0.0015" Kwik-Cote Treatment Note: Due to environmental considerations, Hilti does not plate with cadmium. • Most Hilti zinc plated screws conform to ASTM F 1941 (which replaces ASTM B 633), as tested in accordance with ASTM B 117. The minimum zinc thickness is 5 microns. Refer to Section 3.6.2.5 for screw coating information, Kwik-Cote Treatment Kwik-Cote is a unique copolymer coating that provides greater corrosion resistance than zinc or cadmium plating. 3.6.2.3 Technical Data Ultimate Tensile Strengths - Pullout (Tension), lb (kN)1-2.3,4,5.6.7 3.6.2.1 Product Description 3.6.2.2 Material Specifications 3.6.2.3 Technical Data 3.6.2.4 Installation Instructions 3.6.2.5 Ordering information Listings/Approvals ICC-ES (International Code Council) ESR-2196 COLA (City of Los Angeles) RR 25678 €LA D85 WriiirenVoscarnosounty ICC-ES ESR-2196, provides IBC 2006/2009 recognition of Hilti's Self -Drilling Screw fasteners for most common applications (e.g. CFS connections, gypsum to CFS, etc.), including HWH, PPH, PBH, PWH, PPCH, PFUCH and PFTH head style screws. Screw Designation Nominal Diameter in. Thickness of steel member not in contact with the screw head, GA (in.) 20 (0.036) 18 (0.048) 16 (0.060) 14 (0.075) 12 (0.105) 10 (0.135) *6 0.138 190 (0.85) 250 (1.11) 320 (1.42) 395 (1.76) 555 (2.47) 715 (3.18) *7 0.151 210 (0.93) 275 (1.22) 345 (1.53) 435 (1.93) 605 (2.69) 780 (3.47) *8 0.164 225 (1.00) 300 (1.33) 375 (1.67) 470 (2.09) 660 (2.94) 845 (3.76) *10 0.190 260 (1.16) 350 (1.56) 435 (1.93) 545 (2.42) 765 (3.40) 980 (4.36) *12 0.216 295 (1.31) 395 (1.76) 495 (2.20) 620 (2.76) 870 (3.87) 1120 (4.98) 1/4in. «.. 0.250 345 (1.53) 460 (2.05) 575 (2.56) _ 715 (3.18) 1000 (4.45) 1290 (5.74) The lower of the ultimate pull-out, pullover. and tension fas ever strength of screw should be used fo design. 2 Load values based upon calculations done in accordance with Section E4 of the AISI North American Specification for the Design of Cold -Formed Steel Structural Members (NASPEC) 2007 edition. 3 The NASPEC recommends a safety factor of 3.0 be applied for allowable strength design, a 4) factor of 0.5 be applied for LRFD design or a 47 factor of 0.4 be applied for LSD design. 4 ANSI/ASME standard screw diameters were used in the calculations and are listed in the tables. 5 The screw diameters in the table above are available in head styles of pan. hex washer, pancake, flat, wafer and bugle. 6 The load data in the table is based upon sheet steel with Fo = 45 ksi, For Ft, = 55 ksi steel, multiply values by 1.22. For F = 65 ksi steel, multiply values by 1.44. 7 Refer to Section 3.6.2.5 to ensure drilling capacities. Hilti, Inc. (US) 1-800-879-8000 I www.us.hilLcom I en espanol 1.800.879-5000 1 Hilti (Canada) Corp. 1-800-363.4458 I www.hilti.ca I Direct Fastening Technical Guide 2011 147 Self -Drilling Screws 3.6.2 Ultimate Shear Strengths - Bearing (Shear), lb (kN)122.3,0,6,7 Screw Designation Nominal Diameter in Thickness of steel member in contact with screw head GA (in.) Thickness of steel member not in contact with the screw head, GA (in.) 20 (0.036) 18 (0.048) 16 (0.060) 14 (0.075) >_ 12 (0.105) 20 (0.036) 500 (2.22) 660 (2.94) 660 (2.94) 660 (2.94) 660 (2.94) #7 0.151 18 (0.048) 500 (2.22) 660 (2.94) 880 (3.91) 880 (3.91) 880 (3.91) t 16 (0.060) 500 (2.22) 660 (2.94) 890 (3.96) 890 (3.96) 890 (3.96) 20 (0.036) 525 (2.34) 715 (3.18) 715 (3.18) 715 (3.18) 715 (3.18) #8 0.164 18 (0.048) 525 (2.34) 805 (3.56) 955 (4.25) 955 (4.25) 955 (4.25) t 16 (0.060) 525 (2.34) 805 (3.58) 1120 (4.98) 1170 (5.20) 1170 (5.20) 20 (0.036) 565 (2.51) 830 (3.69) 830 (3.69) 830 (3.69) 830 (3.69) #10.12 0.190 18 (0.048) 565 (2.51) 865 (3.85) 1110 (4.94) 1110 (4.94) 1110 (4.94) 16 (0.060) 565 (2.51) 865 (3.85) 1210 (5.38) 1390 (6.18) 1390 (6.18) 2 14 (0.075) 565 (2.51) 865 (3.85) 1210 (5.38) 1645 (7.32) 1645 (7.32) 20 (0.036) 565 (2.51) 830 (3.69) 830 (3.69) 830 (3.69) 830 (3.69) #10-16 0.190 18 (0.048) 565 (2.51) 865 (3.85) 1110 (4.94) 1110 (4.94) 1110 (4.94) >_ 16 (0.060) 565 (2.51) 865 (3.85) 1210 (5.38) 1215 (5.40) 1215 (5.40) 20 (0.036) 565 (2.51) 830 (3.69) 830 (3.69) 830 (3.69) 830 (3.69) #10-18 0.190 18 (0.048) 565 (2.51) 865 (3.85) 1110 (4.94) 1110 (4.94) 1110 (4.94) 16 (0.060) 565 (2.51) 865 (3.85) 1210 (5.38) 1390 (6.18) 1390 (6.18) t 14 (0.075) 565 (2.51) 865 (3.85) 1210 (5.38) 1645 (7.32) 1645 (7.32) 20 (0.036) 600 (2.67) 930 (4.14) 945 (4.20) 945 (4.20) 945 (4.20) #12-14 0.216 18 (0.048) 600 (2.67) 925 (4.11) 1260 (5.60) 1260 (5.60) 1260 (5.60) 16 (0.060) 600 (2.67) 925 (4.11) 1290 (5.74) 1570 (6.98) 1570 (6.98) 2 14 (0.075) 600 (2.67) 925 (4.11) 1290 (5.74) 1800 (8.00) 1880 (8.36) 20 (0.036) 600 (2.67) 930 (4.14) 945 (4.20) 945 (4.20) 945 (4.20) 18 (0.048) 600 (2.67) 925 (4.11) 1260 (5.60) 1260 (5.60) 1260 (5.60) #12-24 0.216 16 (0.060) 600 (2.67) 925 (4.11) 1290 (5.74) 1570 (6.98) 1570 (6.98) 14 (0.075) 600 (2.67) 925 (4.11) 1290 (5.74) 1800 (8.00) 1970 (8.76) t 12 (0.090) 600 (2.67) 925 (4.11) 1290 (5.74) 1800 (8.00) 2285 (10.16) 20 (0.036) 645 (2.87) 1020 (4.54) 1090 (4.85) 1090 (4.85) 1090 (4.85) 18 (0.048) 645 (2.87) 995 (4.43) 1400 (6.23) 1460 (6.49) 1460 (6.49) 1/4 in. 0.250 16 (0.060) 645 (2.87) 995 (4.43) 1390 (6.18) 1820 (8.10) 1820 (8.10) 14 (0.075) 645 (2.87) 995 (4.43) 1390 (6.18) 1940 (8.63) 2280 (10.14) 0.1111 t 12 (0.090) 645 (2.87) 995 (4.43) 1390 (6.18) t 1940 (8.63)1 2440 (10.85) __ The lower of the ultimate shear bearing and shear fastener strength of screw should be used for design. 2 Load values based upon calculations done in accordance with Section E4 of the AISI North American Specification for the Design of Cold -Formed Steel Structural Members (NASPEC) 2007 edition. It is assumed that the steel sheets are tight together with no gaps. 3 The NASPEC recommends a safety factor of 3.0 be applied for allowable strength design, a 4) factor of 0.5 be applied for LRFD design or a 4) factor of 0.4 be applied for LSD design. 4 ANSI/ASME standard screw head diameters were used in the calculations and are listed in the tables. 5 Load values in table are for Hex Washer Head (HWH and HHWH), Phillips Pan Head (PPH), Philips Truss Head (PTH), Phillips Pancake Head (PPCH), and Philips Flat Truss Head (PFTH) style screws. Philips Bugle Head (PBH) and Phillips Wafer Head (PWH) styles are not covered by this table because they are not intended for attachment of steel to steel. 6 The load data in the table is based upon sheet steel with F. = 45 ksi. For F = 55 ksi steel, multiply values by 122. For F. - 65 ksi steel, multiply values by 1.44. 7 Refer to Section 3.6,2.5 to ensure drilling capacities. 3.6.2.4 Installation Instructions For general discussion of Hilti screw fastener installation, reference Section 3.6.1.7. For allowable diaphragm shear loads and stiffness values for steel roof or floor deck utilizing Hilti self -drilling screws as frame or sidelap fasteners, reference Section 3.5 and download Hilti's Profis DF software at www.us.hilti.com/ decking (US), or www.hilti.ca (Canada). To estimate the number of sidelap screws on a steel roof or floor deck project, reference Section 3.5.1.6. Waming: Because of the potential for delayed hydrogen assisted stress corrosion cracking, many hardened steel fasteners are not recommended for use with dissimilar metals or chemically treated wood when moisture may be present or in corrosive environments. For further information, contact Hilti Technical Support at 1-877-749-6337. Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879.5000 1 Hilti (Canada) Corp. 1-800.363.4458 1 www.hiti.ca I Direct Fastening Technical Guide 2011 149 Screw Fastening Systems 3.6.4 Kwik-Flex Self -Drilling Screws 3.6.4.1 Product Description 3.6.4.2 Material Specifications 3.6.4.3 Technical Data 3.6.4.4 Installation Instructions 3.6.4.5 Ordering Information Listings/Approvals 3.6.4.1 Product Description Hilti Kwik-Flex fasteners combine the in -place economy of self -drilling screws with the strength and performance of bolted connections. The precision - milled point and lead threads of a Kwik- Flex fastener are selectively hardened for dependable self -drilling and tapping. The balance of the fastener retains the ductility. This results in superior resistance to embrittlement that can be caused by stress, dissimilar metals and moisture. ICC-ES (International Code Council) ER-4780 COLA (City of Los Angeles) RR 25095 Es Au oes Hex Washer Head: uses standard tools, efficient drive system, resists pullover Kwik-Flex Head: Marking simplifies inspection Product Features • Virtually immune to embrittlement failure • Self -drilling for convenience, labor savings • Kwik-Cote finish provides up to three times the corrosion resis- tance of cadmium or zinc plating • Complies with the Buy America Act • Suitable for: Aluminum to steel Fire retardant plywood Corrosive environments Tapping Threads eliminate nuts to simplify installation AMU 44 Shank has Grade 5 bolt ductility and strength (SAE J429 and ASTM A 449) without embrittlement; Rc 28-34 hardness Precision -milled drill point speeds installation Hardened to Rockwell C52 min. for drilling and tapping 3.6.4.2 Material Specifications Mechanica Properties Yield Strength, Fy ksi (MPa) Yield Strength, F� ksi (MPa) 92 (634) 120 (828) 3.6.4.3 Technical Data Kwik-Flex Screw Allowable Pull -Out Values (Tension)12,3 Flutes remove metal chips for easy drilling Note: These fasteners address delayed failure due to hydrogen assisted stress corrosion cracking. They are not any more resistant to other corrosion effects than standard Hilti Kwik-Cote screws. Screw Sizd Drill Point Type Pullout (lb) Steel Gauge or Thickness (in.) Aluminum Thickness ( n.) 18 GA 16 GA 14 GA 12 GA 1/8 3/16 1/4 5/16 3/8 1/2 1/8 1/4 3/8 10-16 3 158 200 254 638 677 - - - - - 306 - - 12-14 3 158 210 284 460 620 1159 - - - - 210 914 - 1/4-14 3 159 212 274 480 740 1015 - - - - 240 969 - 1/4-20 4 - 206 260 500 765 1045 1215 1 1275 - - 230 700 1473 1 Steel members shall conform o ASTM A 36. Aluminum members shall be 6063-T5 aluminum alloy. 2 Based on using a safety factor of 3.0, 3 Refer to Section 3.6.4.5 for maximum drilling capacities. 158 Hilti, Inc. (US) 1.800-879-8000 { www.us.hilti.com I en espanol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 i www.hilti.ca I Direct Fastening Technical Guide 2011 Kwik-Flex Self -Drilling Screws 3.6.4 Kwik-Flex Screw Allowable Shear Values''2.3 Screw Sizd 10-16 12-14 Drill Point Type Shear (Ib) Steel Gauge or Thickness - Fastened Material - Base Material Aluminum Thickness (in.) 1/8"-1/4" 1/4-14 1/4-20 18-14 16-16 14-14 GA GA GA 545 693 585 1/8"-3/16" 3/16"-1/4" 1/4"-12 GA 1/8"-1/8" 1/8"-1/4" 3 526 847 662 727 3 558 925 672 967 635 4 540 835 633 980 670 715 587 335 405 660 395 1 Steel members sha 1 conform to ASTM A 36. Aluminum membersshallbe 6063-T5 aluminum alloy. 2 Based on using a safety factor of 3.0. 3 Refer to Section 3.6.4.5 for maximum drilling capacities. 3.6.4.4 Installation Instructions For general discussion of Hai Screw Fastener installation, reference Section 3.6.1.7. For specific Kwik-Flex spacing and edge distance recommendations, reference the following table. Kwik-Flex Screw Specification Table Fastener Size/Diameter Fastened Material Minimum Spacing (in.) Minimum Edge Distance (in.) No. 10 Steel 5/8 9/32 Aluminum 15/32 3/8 No. 12 Steel 11/16 3/8 Aluminum 9/16 7/16 1/41nch Steel 3/4 3/8 Aluminum 5/8 1/2 Description' Countersinking Head SNVD 10 24 x' 1:1/4" WH3 KF . : S-WD 12-14 x 1" PFHUC3 KF $Wd12 14x.1.1/T' ,F It C3KF' S-WD 14-20 x 3" PFHUC4 KF' SrWAti'1+4.20 x ' PFHU KF', *10 Diameter S MO 1O1 16.x /4" PPH3;# 'a , _ S-MD 10-16 x 3/4" HWH3 KF e12 Diameter HWH SMD1214x7,18"HWH3KF 0.210" S-MD 12-14 x 1" HWH3 KF 0.210" S MD 12 14 t 1 1/2" :HWH3 KF : ' 0210' S-MD 12-14 x 1 1/2" HWH4 KF' 0.312" - S-MD'12-14 x 2";HWH3 KF `..:.;.;. , 0.210" S-MD 12-14 x 3" HWH3 KF' 0.210" S-MD 12-24 x 1 3/4" HWH5 KF' 0.500" 1/4 Diameter HWH S-MD 1/4-14 x 1" HWH3 KF 0.220" S-MD 1/4-14 x 1 1/2" HWH3 KF 0.220" S-MD 1/4-14 x 2" HWH3 KF 0.220" S-MD 1/4-20 x 1 1/8" HWH4 KF' 0.312" S-MD 1/4-20 x 1 1/2" HWH4 KF 0.312" S-MD 1/4-20 x 1 3/4" HWH5 KF' 0.500" S-MD 1/4-20 x 2" HWH4 KF 0.312" S-MD 1/4-20 x 2 1/2" HWH4 KF 0.312" S-MD 1/4-20 x 3 3/8" HWH4 KF' 0.312" S-MD 1/4-20 x 4" HWH4 KF1 0.312" 5/16 Diameter HWH S-MD 5/16-18 x 1-1/2" HWH3 KF1 S-MD 5/16-24 x 1-1/2" HWH4 KF' S-MD 5/16-24 x 2" HWH4 KF' 1 Available only through special order. Hiiti, Inc. (US) 1-800-879-8000 i www.us.hili.com 1 en esparto) 1-800-879-5000 I Hilti (Canada) Corp. 1-800.363.4458 I www.hifti.ca I Direct Fastening Technical Guide 2011 159 475 590 570 3.6.4.5 Ordering Information Maximum Drilling Capacity 0.210" ':•4110"_ „ W.. -' 0.312" ,'0412114 0.175" 0.220" 0.312" 0.312" Maximum Total Thcikness (MT) 0.750" 0.500" 2.500" 0.500" 0.470' 0.500" 1.000'1:.; 0.875" 1.500" 2.500" 0.800" 0.450" 0.950" 1.450" 0.500" 0.830" 0.800" 1.330" 1.830" 2.700" 3.500" 0.850" 0.850" 1.350" Recess Box City .PH2.TEK a,.`.: ;5,000. '' PH2 TEK 4,000 PH�3h 500 t HJ.. r. 1 F gt 1},.>.500 t .. 'H2fiEI< ; 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 6,000 5,000 4,000 2.500 2,500 2,000 1,000 2,500 3,000 2,000 1,500 2,500 2,000 1,000 1,500 1,000 500 500 1,000 1,000 1,000 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0030 PROJECT NAME: 4501 BUILDING SITE ADDRESS: 4501 S 134TH PL X Original Plan Submittal Response to Correction Letter # DATE: 3-25-15 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural rJ Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 3 c2LQ-3_oi5 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 4 ^ 93 ii 5 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 VICINITY MAP SCALE : NONE Se GAS UNIT HEATER SCHEDULE MARK MANF. MODEL BTU INPUT BTU OUTPUT VOLTAGE FLA NET.WT. UH 1 REZNOR UDAP 45 45,000 37,350 115V 2.4 59 LB. UH 2 REZNOR UDAP 45 45,000 37,350 115V 2.4 59 LB EXHAUST FAN SCHEDULE MARK MANF. MODEL CFM S.P. VOLTS PHASE Hp/A/W NOTES EF 1,2 BROAN QTR110 90 0.2" 115 1 71 W LOCATED ON CEILING EF 3,4 BROAN QTR110 90 0.2" 115 1 71 W LOCATED ON CEILING CONTROL NOTE: SWITCH W/LIGHT BY ELECTRICIAN COMMISSIONING PLAN ALL COMMISSIONING OF HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS AS REQUIRED BY SECTION C408 'SYSTEM COMMISSIONING' OF THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATI❑N, LLC, THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE 'COMMISSI❑NING COMPLIANCE CHECKLIST' SHOWN BELOW. AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTI❑N C408 OF WSEC THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATI❑N WILL BE SIGNED AND DATED. THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY. SECTION C408.1.2.1 OF WSEC, Project Information COMMISSIONING COMPLIANCE CHECKLIST Project Name: Project Address: Commissioning Authority: Commissioning Plan (Section C408.1.1) Commissioning Plan was used during construction and Included Items below • A narrative description of activities and The persomel Intended to accorplish each one • Heosurable criteria for performance • Functions to be tested Systems Balancing (Section C408,2,2) Systems Balancing has been completed • Air and Hydranic systems ore proportionately balanced In a manner to FMst minimize throttling losses • Test ports are provided on each pimp for measuring pressure across the pump Functional Testing (Sections C408.2.3) ® HVAC Equipment Functional Testing has been completed (Section C408.2.3.1) HVAC equipment has been tested to demonstrate the Installation and operatlon of components, systems and pl systeans and m-by-specifsystem IC Interfacingations relationships in accordance with approved ® HVAC Controls Functional Testing has been completed (Section C408.2.3.2) HVAC control have been ested to ensure that control devices are calibrated, adjusted and operate property. Sequence of opec atlon hh ve been functionally tested to ensure they t r tr Itb approved plans anti specfticattlonsw Economizers Functional Testing has been completed (Section C408.2,3,3) Economizers operate In accordance with manufacturer's specifications Supporting Documents (Section C408,1,3.2) ® Manuals, record documents and training have been completed or are scheduled • System documentation has been provided to the owner or scheduled • Record documents have been submitted to Diner or scheduled • Tralnhg has been completed or scheduled date' Commissioning Report (Section C408.1.2) ® Preliminary Commissioning Report submitted to Owner and Includes Items below • Deflctendes found during testing required by this section wHch have not been corrected et the the of report preparation • Deferred tests, which cannot be performed et the time of report preperation due to climatic conditions. Certification ® I hereby certify that all requirements for Commissioning have been completed In accordance with the Washington State Energy Code, Including all Items above. Building Owner or Owner's Representative�-----W--------r---- Date rREVISIONS No changes shall bo made to the scope of work without prior approval of Ttl!(��,,11 P',,,- i; vi i.- . P!oTE: ;ovs;:. k'i I 1 cr,;fr-i;1!iM; GAS PACKAGE EQUIPMENT SCHEDULE MARK MANF. MODEL TONS. AIRFLOW CFM SP WG MIN. OSA POWER DRIVE COOLING HEATING ELECTRICAL WEIGHT FILTER SIZES NOTES CFM HP STYLE TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE M.C.A. TOTAL BTUH BTUH BTUH (%) (V) (A) LBS NO. (LxWxD) RTU 1 LENNOX ZGA036S4B 3.0 1200 0.5 240 . . 1.00 BD 35,800 13.0 11.5 65,000 52,000 80% 460 30 8.0 645 4 (14" x 20" x 2") 1 0.5 240 1.00 BD 35,800 13.0 11.5 65,000 52,000 80% 460 . 30 8.0 645 4 (14" x 20" x 2") 1 RTU 2 LENNOX ZGA036S4B 3.0 1200 NOTES: 1. THE ROOFTOP UNIT COMES COMPLETE WITH AN ECONOMIZER AIR TERMINAL UNIT SCHEDULE ITEM MARK MANUFACTURER MODEL MATERIAL MOUNTING FINISH SIZE REMARKS CEILING DIFFUSER CD-1 TITUS MCD STEEL SURFACE WHITE SEE SCHEDULE LAY -IN CEILING -BORDER TYP 3 HARD CEILING -BORDER TYP.6 CEILING GRILLE CG-1 TITUS 50F ALUMINUM SURFACE WHITE = NECK SIZE SQ SUPPLY DIFFUSER SIZE SIZE RANGE 6"X6" 0-100CFM 8" X 8" 101 - 250 CFM 10" X 10" 251 - 425 CFM 12"X12" 426650 CFM FILE 073 Permit Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: L4 %i I IS City of Tukwila BUILDING DIVISION SEPARATE F r:'?•.1ST' REQUIRED FOR: ❑ Mechanical I( Electrical Plumbing Gas Piping CRy of i L s}('3.' La GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS-7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 . GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T-BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOiv1ATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. C402.4.5.4 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. C403.4.1 MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2012 SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION 0 DUCT SECTION SUPPLY va DUCT SECTION - RETURN/EXHAUST RECTANGULAR DUCT 14'x8' ROUND DUCT 14' FLEXIBLE DUCT MVD MANUAL VOLUME DAMPER I 1 I 4BDD BDD BACKDRAFT DAMPER I 1 I QM MD MOTORIZED DAMPER I I FD FIRE DAMPER -r► FSD FIRE/SMOKE DAMPER (120V POWER REQ.) CEILING RADIATION DAMPER -EH SD SD SMOKE DETECTOR Q T THERMOSTAT S SENSOR R REFRIGERANT LINES -R- - - -R -G- G NATURAL GAS LINES - - -G Ea CEILING DIFFUSER (SUPPLY) F CEILING DIFFUSER (RETURN/EXHAUST) 3 EXHAUST FAN (CEILING MOUNTED) INLINE FAN D8 PROPELLER FAN 1/ SIDEWALL DIFFUSER 1 I DUCT FITTING 14- ZD ZONE DAMPER Mk111/ NI TA 4.1 rwl; w 11:1 a) a0 N NOT PUBLISHED, ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS, U) 4 0 N) 0 Q 0 0 0 REVIEWED FOR CODE COMPLIANCE APPROVED. APR01201 City of Tukwila BUILDING DIVISION DESIGN DEVELOPMENT FOR CONSTRUCTION 0 W In AS BUILT DRAWINGS IN ■ ❑ SEATTLE, WASHINGTON 98108 727 SOUTH KENYON EVERGRL954R2 z 0 m l(7 d' HVAC COVER SHEET REVISIONS NO DATE ITEM RECEIVED ciTY OF TUKWILA MAR 2 5 2015 PERIVIIT CENTE DWG. BY: GN CHK. BY: MG/JS JOB NO.: 514400 SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. ND PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LDSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. 45 CFH 3/4" r WAREHOUSE 101 3/4" r- L - J 14" • -8" UP 350 CFM 3/4" WA % EF) 350 CFM 16" EH OU SE 101 GAS METER IMIM) 200' 110 CFH 1" 3/4" 1- J ON ROOF j- 65 CFH HVAC. FLOOR PLAN SCALE : 1/8" = 1'-0" J Q 1" 150' 110 CFH FAX (206) 763 2389 (206) 763 - 1744 LO 4 O M O I IJ 0 In ZZ N) O LIJ Q 0 LIJ 0 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 1 2015 City of Tukwila BUILDING DIVISION DEVELOPMENT ISSUED FOR CONSTRUCTION AS BUILT DRAWINGS SEATTLE, WASHINGTON 98108 727 SOUTH KENYON EVERGRL954R2 z CT) -J m yr- •411- HVAC FLOOR PLAN REVISIONS NO DATE ITEM RECEIVED CITY OF TUKWIL!', MAR 2 5 2015 PERMIT CENTER DWG. BY: GN CHK. BY: MG/JS JOB NO.: 514400 SHEET: