Loading...
HomeMy WebLinkAboutPermit M15-0050 - PRICECO - AIR CONDITIONING UNIT, HEAT PUMP AND GAS UNIT HEATERPRICECO 1002 ANDOVER PARK E EXPIRED 11/23/15 M15-0050 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049101 Permit Number: 1002 ANDOVER PARK E Project Name: PRICECO Issue Date: Permit Expires On: M15-0050 5/27/2015 11/23/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: 1006 ANDOVER ASSOCIATES 5851 S 194TH ST C/O CABLE MANAGEMENT, KENT, WA, 98032 JIM DIDCAKE 420 37 ST STE H , AUBURN, WA, 98001 BUDGETHVACUS LLC 3902 W VALLEY HWY N STE 408 , AUBURN, WA, 98001 BUDGEC*882B7 Phone: (206) 473-9914 Phone: (206) 473-9914 Expiration Date: 1/28/2016 DESCRIPTION OF WORK: REPLACE EXISTING 40 YEAR OLD 2.5 TON A/C UNIT WITH ELECTRIC HEAT WITH A NEW HIGH EFFICIENCY 2 TON HEAT PUMP. REPLACE GAS UNIT HEATER IN WAREHOUSE. Valuation of Work: $15,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $389.62 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name (\/\., 1 lb C.-4 Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2013 edition). 11: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: IS - Date Application Expires: t 1 _ 10 (For office use only) M -fX1.Aj MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: / O (3 Z. G\IF,1f K C ;L.ti(G Tenant Name: Pi CE Ce / King Co Assessor's Tax No.: Suite Number: New Tenant: PROPERTY OWNER Name: L S R Pi 4 f rri £s, Address:-s31 � iu , 0 y S" r'° City: k,z i , State: G.lA Zip.,B 1Z CONTACT PERSON — person receiving all project communication Name --I NA,.b i ib L. K .+C Address: // City: � Zip: Phone: � Fax: S Email: 1-4 \/4C .0 S -''I I'" i D P iv-0 ET Floor: jiir Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: c J,c, c. .-r.1,4 V G ' 0 5-- Address: ci, 2,4 7'--t.[t , S-- * it City: ,i1/4V eV IZr,„j State: G..ftc Zipmao t Phone: hoc—Y?3-29/Fp: Contr Reg No.: 6 carl6Q.... 9,R9ExpDate: `_3/` Lc Tukwila Business License No.: CO Valuation of project (contractor's bid price): $ t ."✓ ooe Describe the scope of work in detail: A.C- PG A i me #(/c vD 7- , r,7'X( Cc. cTlt'c .r. 7.7e A/c J /d/S 4' fi 7—es," j kE-XT pvwl/. Ae-PGAc; S On-'YAf€c.(IdR. ,cov�s Use: Residential: Commercial: New ❑ Replacement ❑ New ❑ Replacement A Fuel Type: Electric � Gas Other: H:Wpplications\Forms-Applications On Line \2011 Applications Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Fumace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: - ' 14 b 1 b Cr 4 Mailing Address: ti- b 3 —?c=u tJ CJ—s; -41"4.4 Date: 1 L 5 Day Telephone: --02.6 —Ya 3 — ? 9 1 `{ 4u o CJ JA 9 66 / City State Zip H:WpplicationsWorms-Applications On Line \20I 1 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $389.62 M15-0050 Address: 1002 ANDOVER PARK E Apn: 2623049101 $389.62 MECHANICAL $374.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $267.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $74.93 TECHNOLOGY FEE $14.99 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5228 R000.322.900.04.00 0.00 $14.99 $389.62 Date Paid: Wednesday, May 06, 2015 Paid By: BUDGETHVAC.US LLC Pay Method: CREDIT CARD 121158 Printed: Wednesday, May 06, 2015 11:15 AM 1 of 1 CLLWSYSTEMS 2 Google eALIE civ:jeft Permit No. (V\ 19 'VD P:C5 Approval the violation of approved Hold By: Da - , met (491:4*- 7-'71 P ATP_ PER 74; -I is subject to errors and omissions. does not authorize tic cc or c7...7,^^-41. Receipt Cop and conditions is acknow:-4: City of Tukwila BUILDING DIVISION frlISOO cal Piping r- 1 WED FOT CO COMPLIANCE APPROVED MAY 1 9 2015 12)f City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 0 6 2015 PERMIT CENTER REVISIONS anges shall ho made to the scope work withoprior approval of TtL Building Division .'wtUrquirc nEw On submittal Wan QAC.4 h' .�.._ g us' 3902 W Valley Hwy. N, Ste. #408 Auburn, WA 98001 Project /O 6.2 4 b t L1CJ Job # Date L/'' �' /✓ By - k I — Page Of l z ,47 FILE COPY fi)<I si IN RN A1iLC, I`{'DIT? l`��. t t : �'F {j C. t.t T, k i"" -'r-QT � L I c, R rr +1 c) P-"r I S:. 3.20 Lt �� i' P L.3 m � rr ?LKc 41 1 IQij: I l'7: , Cis„, �, /C + XT 4 'r . M1S--00E0 RECEIVED CITY OF TUKWILA MAY 0 6 2015 PERMIT CENTER IXLECON Single Packaged Heat Pump 14 SEER Convertible 4WCC4024A1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance." MIS'OO'O RECEIVED CITY OF TUKWILA MAY 0 6 2015 TAG: PERMIT CENTER A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2014 4WCC4024A—SUB-1A-EN ($)!ngersollRand Product Specifications MODEL 4WCC4024A1000A RATED Volts/PH/Hz 208-230/1/60 Performance Cooling BTUH (a) 24600 Indoor Airflow (CFM) 758 Power Input (KW) 1.9 EER/SEER (BTU/Watt-Hr.) (b) 12.00 / 14.00 Sound Power Rating [dB(A)] (c) 66.4 PERFORMANCE HEATING (High Temp.) BTUH 22000 Power Input (KW) 1.8 (Low Temp.) BTUH 14300 Power Input (KW) 1.12 HSPF (BTUH/Watt-Hr) 8.0 POWER CONN. — V/Ph/Hz 208-230/1/60 Min. Brch. Cir. Ampacity (d) 19.4 Fuse Size — Max. (amps) 30 Fuse Size — Recmd. (amps) 30 COMPRESSOR SCROLL VOLTS/PH/HZ 208-230/1/60 R.L. Amps — L.R. Amps 12.8 / 58.3 OUTDOOR COIL — TYPE SPINE FIN Rows/F.P.I 2 / 24 Face Area (sq. ft.) 13.32 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE INDOOR COIL — TYPE PLATE FIN Rows/F. P.I 3 / 15 Face Area (sq. ft.) 3.5 Tube Size (In.) 3/8 Refrigeration Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT OUTDOOR FAN — TYPE SWEPT DIA. (IN.) 23.4 DRIVE/NO. SPEEDS DIRECT/ 3 CFM @ 0.0 in. w.g. (e) 2550 Motor — HP/R. P. M 1/12 / 850 Volts/Ph/Hz 208-230/1/60 F.L. Amps/L.R Amps .54 / .82 INDOOR FAN — TYPE CONSTANTTORQUE ECM Dia. x Width (In.) 10.62 X 10.68 Drive/No. Speeds DIRECT / 3 CFM @ 0.0 in. w.g. (e SEE FAN PERF TABLE Motor— HP/R.P.M. 1/3 / 1050 Volts/Ph/Hz 208-230/1/60 F.L. Amps 2.8 FILTER / FURNISHED NO Type Recommended THROWAWAY Recmd. Face Area (sq. ft) (a) 2.7 REFRIGERANT R-410 Charge (lbs.) 5.74 CHARGING SPECIFICATIONS Subcooling 16° DIMENSIONS H X D X W Crated (In.) 46 X 45 X 52 WEIGHT Shipping (lbs.) / Net (lbs.) 40 328 \ (a) (b) (c) Rated in accordance with AHRI Standard 210/240. Rated in accordance with D.O.E. test procedure. Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (d) Calculated in accordance with currently prevailing Nat'l Electrical Code. (e) Standard Air — Dry Coil — Outdoor. (0) Standard Air — Dry Coil — Indoor (co Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. LNr EC,a�aM izQ �, .3 tE'F-Z- t .� 't 2 4WCC4024A—SUB-1 A -EN Outline Drawings 79.50 [3-1/8] 398.22 [15-II/16] (OUTSIDE) BACK DUCT OPENINGS 17.78 SECTION X-X TYPICAL (81 SIDES OF SIDEFLOW DUCT OPENINGS Figure 2. 2 - 3 TON MODELS 296.62 [11-11/16] (OUTSIDE) 1:millf 58.19 [2-9/32] 177.55 [7] 398.22 [15-11/16] (OUTSIDE) 1155.4S [45-1/2] (SURFACE AREA) BACK SIDE Model Height MM/IN APPROX. CORNER WEIGHT KG / LBS SHIPPING WIGHT KG / LBS TOTAL UNIT WIGHT KG / LBS CENTER OF GRAVITY MM/IN. A W1 W2 W3 W4 B C 4TCC4024 898.53 [35-3/8] 58.3 [1291 36.8 [81] 26.1 [58] 41.0 [90] 196.1 (432) 162.4 (358) 479.8 [18.9] 527.8 [20.8] 4TCC4030 61.3 [135] 38 7 [85] 27.5 [61] 43.1 [95] 204.8 (451) 171.1 (377) 406.5 [16.0] 594.1 [23.4] 4TCC4036 949.33 [37-3/8] 61.7 [136] 38 9 [86] 27.7 [61] 43.7 [96] 205.7 (453) 172.0 (379) 414.3 [16.3] 697.6 [27.5] 4WCC4024 52.9 [117] 33.3 [73] 24.1 [53] 38.3 [84] 182.3 (402) 148.6 (328) 430 [16.9] 565.3 [22.3] 4WCC4030 1050.93 [41-3/8] 55.3 [122} 50.3 [110) 16.6 [37] 39.2 [86] 195.0 (430) 161.3 (355) 413.5 [16.3] 581 [22.9] 4WCC4036 59.6 [131] 37 3 [82] 26.6 [59] 41.7 [92] 199.0 (439) 165.3 (364) 430 [17.0] 535 [21.1] 4 4WCC4024A-SUB-1 A -EN Outline Drawings Figure 3. 2 - 3 TON MODELS 304.80 [12] (INSIDE) 75.41 [2-31/32] RECOMMENDED SERVICE CLEARANCE MM11N. NITR ECONOMIZER BACK SIDE 304.8 [121 762.0 1307 LEFT SIDE 762.0 (301 911.4 [361 RIGHT SIDE 609.6 1211 FRONT SIDE 1066.8 142] CLEARANCE TO COMBUSTIBLE MATERIAL MN/IN. BOTTOM 0 BACK SIDE 25.4 [11 LEFT SIDE 152.1 16] RIGHT SIDE 152.4 [61 FRONT SIDE 304.8 1121 TOP 911.1 [361 35919 [14-5/32] 24V ENTRY 1 288.42 225f 68 [11-II/32] [8.-/8] 117.13 [4-5/8] 85.22 [3-I1/32 406.40 [161 (INSIDE) BOTTOM DUCT OPENINGS 173.46 [6-27/32] 406.40 [161 (INSIDE) 167.89 [6-5/8] a. OMNI 128.08 [5-1/32] RIGHT SIDE POWER ENTRY 28.58 [1-1/81 DIA. KNOCKOUT POWER ENTRY 28.58 [1-1/81 DIA. KNOCKOUT 34.93 [I-3/81 DIA. KNOCKOUT 50.01 [I-31/32] DIA. KNOCKOUT SINGLE POINT ENTRY 34.93 [I-3/8] DIA. KNOCKOUT 50.01 [I-31/32] DIA. KNOCKOUT 62.11 [2-15/32] DIA. KNOCKOUT 4WCC4024A-SUB-1 A -EN 5 Supplementary Electric Heater Table 3. BAYHTRV — Supplementary Electric Heaters UNIT MODEL ELECTRIC HEATER MODEL RATED VOLT- AGE PHASE AMPS HEATER CAPACITY NO. OF STAGES KW/STAGE MCA MAX. FUSE OR HACR CKT BKR SIZE CANADA ONLY MAX. CKT BKR SIZE KW BTUH 1 2 4024-4060 BAYHTRV105 208/240 1 18/21 3.76/5.0 1 8 00/ 1 35 0/ - 23/26 25/30 25/30 4024-4060 BAYHTRV108 208/240 1 29/33 6.0/8.0 20 300500/ 1 8 p/ - 36/41 40/45 40/45 4024-4060 BAYHTRV110 208/240 1 36/42 7.5/10.0 341 00/ 1 10.0 - 45/52 45/60 45/60 4030-4060 BAYHTRV115 208/240 1 54/63 11.27/ 15.0 38500/ 51200 2 7.5/ 10.0 3.76/ 5.0 68/78 70/80 70/80 4042-4060 BAYHTRV120 208/240 1 72/83 15.0/ 20.0 51200/ 68300 2 7.5/ 10.0 7.5/ 10.0 90/ 104 90/110 90/110 4042-4060 BAYHTRV125 208/240 1 90/ 104 18.78/ 25.0 64100/ 85300 2 11.26/ 15.0 7.5/ 10.0 113/ 130 125/150 125/150 Table 4. BAYSPEK — Single Power Entry Kit SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION UNIT MODEL SINGLE POWER ENTRY KIT HEATER MODEL MIN CKTAMP MAX OVER -CURRENT DEVICE 4WCC4024A BAYSPEK60 BAYHTRV105 45 50 BAYHTRV108 60 60 BAYSPEK62 BAYHTRV110 71 80 8 4WCC4024A-SUB-1 A-E N Optional Equipment — Filter Rack Optional Equipment — Economizer Table 5. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Retum Air Opening) HVAC Unit Economizer Unit Application Models BAYECON101A 4024-036 \ Economizer rain hood .�eee.®.-.®.-.®® '. 000000000.� 0 0 0 0 0 0 11=5 0 0 0 0 r, .q p-ri , Outside air dampers r , Mist �separately eliminator c_ -''/ Return air dampers 1 Required ,.......----filter kit, order BAYECON102A 4042-060 • Relief damper / -- Return Duct Roofcurb �- Table 6. BAYCON200, 201A Horizontal Economizer and Rain Hood Economizer - Duct Q� ,6 e" \ u B� / • I`'. < Mixed Sensor �) Air ---jr' r„ / ( ' ,1 l'''"''',.-- 440 _® • Gaskets (2) Rain Hood Economizer Models A B C D E F F BAYECON200AA 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201AA 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 10 4WCC4024A-SUB-1 A -EN ALUMINIZED STEEL GAS -FIRED HEAT EXCHANGER ELECTRONIC IGNITION SYSTEM 10-15 TON DUAL CIRCUITED TRANE 5-15 TON COOLING AND HEATING/COOLING UNITS FILE COPY CONDENSER FAN CONDENSER SECTION OVERHANGS ROOF CURB LIFTING LUG BURNER FLAME VIEWING PORT FORCED COMBUSTION BLOWER CONDENSER COIL EVAPORATOR COIL URN AIR %:f;a" COMPRESSOR SUPPLY AIR 2.4 TON COOLING ONLY SUPPLY FAN FORCED COMBUSTION BLOWER ELECTRONIC IGNITION SYSTEM HORIZONTAL SUPPLY AND RETURN OPTION GASKETED ACCESS PANELS WITH QUICK -RELEASE LATCHES AND LIFTING HANDLES ALUMINIZED STEEL GAS -FIRED HEAT EXCHANGER EVAPORATOR COIL CONDENSER FAN CONDENSER COIL COMPRESSORRECEI 234-4 TON HEATING/COOLING UPPlibTY OF T w ARI7E AIR COND/TIONING MECHANICAL SPECIFICATIONS PERMIT CENTER GENERAL — All units are factory assembled, piped, internally wired and fully charged with R-22. All units are designed to operate at outdoor ambient temperatures as high as 120° F. 2-10ton units certified byARI Standard 210and 270. National Rating Standard of the Air Conditioning and Refrigeration Institute. SFCAISFHA Heating/Cooling units design i&cer- tified by American Gas Association (A.G.A.) specifically for outdoor applications using propane or natural gas. All Cool- ing Units are Underwriters' Laboratories listed. All units are designed for outdoor rooftop or ground level installation. Exterior surfaces of all units are phosphatized, zinc -coated steel with epoxy resin primer and gray -green baked enamel finish. All 2-15 ton Horizontal units have weldedshell, 3600 RPM compressors. 400ro 5-15 TON HEATING/COOLING (SFCA) AND COOLING (SAGA) UNITS CASING — All access panels are gasketed and provided with fasteners and handles. One inch, one pound density foil - faced glass fiber insulation is on heat exchanger section (SFCA units). Same composition mat -faced insulation is in evaporator section. REFRIGERATION CONTROLS — Refrigeration controls include . condenser fan, evaporator fan and compressor contactors, and 24 volt transformer. Safety controls include high and low pressure controls, (except 5 ton), winding thermostat and compressor overloads. Cycle guard prevents unit cycling on overloads and safety controls to be reset at thermostat inside the building. Each circuit of the unit has a separate set of refrigeration controls. (10-15 has 2 independent circuits). FIGURE 14-1 k/.s! f G / E DIMENSIONS — SAHA 2-4 „s"-A At< , 3Y4 N.P.T. DRAIN CONN. CENTERED FIGURE 14-2 NOTE: Supply return casing for 3 and 4 ton only. "C" IDIA. K.O. ELECT. HEAT CONN. PIPE SUPPORTS FIELD SUPPLIED SIDE VIEW END VIEW / FIGURE 14-1 Page 14 — $AHA Unit 20-40 Unit Dimensions SAHA 20 25 30 40 A 131/s 16% 20% 28% B 12914 1514 19 25% C 11 114 "-'2�1 2 Net Wt. 300 320 / 356 454 Ls I FIGURE 14-2 Page 14 — Clarification of Cut -Away SAHA 20 25 30 40 H 3914 47+/4 A 1814. 19%4 1 23 3144 B 1714 2014 24 3214 TABLE 14-1- Net Weights_ ACCESSORY NET WEIGHTS SUPPLY RETURN CASING 180 RELIEF DAMPER 15 ECONOMIZER 92 OUTSIDE AIR HOOD 56 ROOF CURB 56 CONCENTRIC DUCT 60 MOUNTING HOLES 16 DIA. (4) 60 i 1334 1Y4 35114 SUPPLY -RETURN CASING ECONOMIZER AND OUTSIDE AIR HOOD 13T/a 2 2 x 2 NAILING STRIP 41413 491 ' �a ,5 .� ' CONCENTRIC DUCT t4) .Ntr CONCENTRIC DIFFUSER 1314 14 City of Tukwila Department of Community Development 10/1/2015 JIM DIDCAKE 420 37 ST STE H AUBURN, WA 98001 RE: Permit No. M15-0050 PRICECO 1002 ANDOVER PARK E Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/23/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/23/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley2 Permit Technician File No: M15-0050 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0050 PROJECT NAME: PRICECO SITE ADDRESS: 1002 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 05/06/15 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: k,i IIJ Building Division Public Works Wu 002 Fire Prevention U Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/07/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 06/04/15 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 BUDGETHVACUS LLC Page 1 of 2 Home lnicio en Espanol Contact Search L&I A-Z Index Help My Secure I &I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & industries BUDGETHVACUS LLC Owner or tradesperson Principals DIDLAKE, JAMES RICHARD, PARTNER/MEMBER Doing business as BUDGETHVACUS LLC WA UBI No. 603 169 929 3902 W VALLEY HWY N STE 408 AUBURN, WA98001-2428 206-473-9914 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................................................................... Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. BUDGEL*882B7 Effective — expiration 01 /27/2012— 01/28/2016 Bond Wesco Insurance Co Bond account no. 46WB041039 $6,000.00 Received by L&I Effective date 01/28/2014 01/26/2014 Expiration date Until Canceled Bond history Insurance Security National Insurance Policy no. NA110010600 $1,000,000.00 Received by L&I Effective date 01/23/2015 01/26/2015 Expiration date 01/26/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&l Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603169929&LIC=BUDGEL* 882B7&SAW= 5/27/2015