HomeMy WebLinkAboutPermit M15-0064 - RIVERTON APARTMENTS - BUILDING A - DUCTLESS HEAT PUMPRIVERTON APARTMENTS BUILDING A 14461 41 AVE S M15-0064 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0040000244 Permit Number: 1446141ST AVE S Project Name: RIVERTON APARTMENTS - BLDG A Issue Date: Permit Expires On: M15-0064 6/15/2015 12/12/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 VIELKA ANSARI 2820 A ST , TACOMA, WA, 98402 RESICON LLC 19817 SUNNYSIDE DR N #J304 , SHORELINE, WA, 98133 RESICL*874OF 111 Phone: (253) 629-7952 Phone: (253) 355-5565 Expiration Date: 9/6/2015 DESCRIPTION OF WORK: INSTALL DUCTLESS HEAT PUMP MINI SPLIT IN EACH UNIT (6) UNITS Valuation of Work: $7,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $285.10 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree tote conditions attached to this permit. Signature: Print Name: I 6f2/s%7 Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWL_ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. K l' DO yi4. Project No. Date Application Accepted: CQ ' 0- Date Application Expires: iiit, (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION )� ,, King Co Assessor's Tax No.: Site Address: I44{t 1 4t4,T Ave SUU (P) Suite Number: N/A Floor: N/A Tenant Name: Riverton Terrace - King County Housing Authority New Tenant: ❑ Yes O..No PROPERTY OWNER Name: King County Housing Authority Address: 600 Andover Park West City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Vielka Ansari Address: 2820 A Street City: Tacoma State: WA Zip: 98402 Phone: (253) 625-7952 Fax: Email: Vielka@Resiconllc.com MECHANICAL CONTRACTOR INFORMATION Company Name: Resicon LLC Address: 2820 A Street City: Tacoma State: WA Zip: 98402 Phone: (253) 625-7952 Fax: Contr Reg No.: RESICL*919N7 Exp Date: 08/19/2015 Tukwila Business License No.: BUS-0996147 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Install Ductless Heat Pump mini Split in each unit 000 td h n9 Pt Ras Co u u, Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric 0 Gas El Other: H:\Applications\Forms-Applications On Line\20I I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cool ing system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: Print Name: Vielka Ansari Mailing Address: 2820 A Street Date: 06/03/2015 Day Telephone: (253) 625-7952 Tacoma WA 98402 City State Zip H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $285.10 M15-0064 Address: 14461 41ST AVE S Apn: 0040000244 $285.10 MECHANICAL $274.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $54.83 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5463 R000.322.900.04.00 0.00 $10.97 $285.10 Date Paid: Friday, June 05, 2015 Paid By: RESICON Pay Method: CHECK 1662 Printed: Friday, June 05, 2015 10:14 AM 1 of 1 r ,1 SYSTEMS RESICON LLC Page 1 of 2 Horne Irricio en Espanol Contact A-Z.Index Help My Secure I,8rI Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & industries RESICON LLC Owner or tradesperson Principals CHRISTENSEN, CRAIG ALLEN, PARTNER/MEMBER Doing business as RESICON LLC WA UBI No. 602 942 448 2820 A STREET TACOMA, WA98402 253-355-5565 KING County Business type Limited Liability Company Governing persons CRAIG CHRISTENSEN VIELKA ANSARI; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. RESICL*919N7 Effective — expiration 08/27/2009— 08/19/2015 Bond ................. American Contractors Indem CO Bond account no. 100229176 $12,000.00 Received by L&I Effective date 08/16/2013 08/19/2013 Expiration date Until Canceled Bond history Insurance .......................... Starr Surplus Lines Insurance Policy no. SLPG-GL02783-00 Received by L&I 08/19/2014 Arch Insurance Co Policy no. ag100336800 $1,000,000.00 Effective date 08/19/2014 Expiration date 08/19/2015 $1,000,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602942448&LIC=RESICL*919N7&SAW= 06/15/2015 jal(5'-00(01-1 --t INSPECTION RECORD �^ / Retain a copy with permit? ECTION NO. TEZ/76—(t PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr c,: ' /0 V \ /ire%-/C/ /5 �u of Inspection: g,itel C� Address: f 11� Date Called: Spe is I structions: • . Date Wanted: / - . l/ Z p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspectio. , fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. .r7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ,1/t/may P ct: s 41 o WAype of Inspection: /I.�1✓CDate 101:6�J Called: if Special Instructions: ,g, 'j Date Wanted: l%lw m. Reque er Phan eDlq 5. /„9. ,_/ / 5_, Approved per applicable codes. COMMENTS: 1----l/ Corrections required prior to approval. /M© cwRepivoS� Inspector: 05' G'ivatz____ Date: REINSPECTION FEE REQUIRED. Prior to next inspectioh. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDIN WMI 6300 Southcenter Blvd., #100, Tukwila. WA 9818 `(2 6 431-3670 Permit Inspection Request Line (206) 438-9350 flog,��: � B lC Pr erkt: ( ver fok. A((r Type of Inspectio : ‘ . 1 vq 1 Address: iIttr I WI--AkSer Date Called: Special Instructions: 6149 01— fr•efolt Date Wanted• a.m. Requester: V -Z'% Res 1 CJ6 G( Phone No: _ ZS3 --� — 7(efe, 'e Approved per applicable codes. • r tf L( ,6c'37 Corrections required prior to approval. COMMENTS: 1 Ait&-icac4 ( Pc &/ 144--or , Pfau? k � e(ec c0 1 Pt -ram( at IrritI � P ,, r (re_ ( r utta-1-; k 4 /41- v 0 7-7 r °' d pi Inspector: Dater (o v /J REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. "1 o g 00 .r 41. 9,0 CO t if i I's TA <TR%e T c 510Fi55 • Q NC 0 Cf. so CQ O c CD z O Q?11' CD " 3 0 CD (/) cD ci3AOJlddd JNINNd"1d r {{N - VY 4,1/4 aA P7 IN Ti RECEIVED 1 CITY OF TUKWILA JUN .0, 5 2015 PERMIT CENTER O O73 - yom Zo -�p"C)ni Z 0 0 P3 m 1,m9 -0* '2cA I i .. - a . a , .,..,...,,..,,,,,, . • ,....., . ,. 1..r ' 1. 51 'c! A a 4. 5 1 1 I 2 5 13 rJ c11 al el o 3 1 a .s 5 3 Tr 1 1 117 -1; I I 1.1 4 --"‘f \( r • drri r1 .L a. ff .1 ! t71 - -1 r _ 1 1 ' "MITSUBISHI ELECTRIC COOLING & HEATING Job Name: M-SERIES SUBMITTAL DATA: MSZ-GE12NA-8 & MUZ-GE12NA 12,000 BTU/H WALL -MOUNTED HEAT -PUMP SYSTEMS Location: Date: Purchaser: Submitted to: Engineer: For ❑Reference DApproval ❑Construction System Designation: Schedule No.: NERSY STAR Indoor Unit MSZ-GE12NA-8 Most Efficient 2013 www.energystargev Wireless Remote Controller GENERAL FEATURES • Wall -mounted indoor unit • Standard Hybrid Catechin Prefilter is included with indoor unit • Quiet operation • Auto fan speed control: Quiet, Low, Medium, High, and Super High; • Hand-held Wireless Remote Controller • Indoor unit powered from outdoor unit using A -Control • Auto restart following a power outage • Base heater is available as an option • Anti -allergy Enzyme Filter • Limited warranty: five years parts and seven years compressor ACCESSORIES Outdoor Unit o Base Heater (MAC-640BH-U) o Drain Socket Assembly (MAC-860DS) Indoor Unit o Condensate Pump (230V; SI3100-230) Controller Options o Wireless Wall -mounted Remote Controller Kit (MHK1)* o Portable Controller (MCCH1)* o Outdoor Air Sensor (MOS1)* *See Submittal for information on each option. o Wired Wall -mounted Controller (PAR-21MAAU requires MAC-3331F) o System Control Interface (MAC-333IF) Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Outdoor Unit: MUZ-GE12NA REVIEWED FOR CODE COMPLIANCE APPROVED JUN 10 2015 CI of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN U.5 2015 PERMIT CENTER IR MI5 -CO0- SPECIFICATIONS: MSZ-GE12NA-8 & MUZ-GE12NA Minimum Capacity SEER 20.5 Btu/h/W Total Input 960 W Heating at 47°F* Rated Capacity Cooling* Rated Capacity 12,000 Btu/h 3 800 Btu/h 14,400 Btu/h Minimum Capacity 5,500 Btu/h HSPF 10.0 Btu/h/W Total Input 1,170 W Heating at 17°F* Rated Capacity 8,800 Btu/h Rated Total Input 900 W Maximum Capacity** 11,200 Btu/h Maximum Total Input 1,200 W * Rating Conditions per AHRI Standard Cooling I Indoor: 80° F (27° C) DB / 67° F (19° C) WB Cooling I Outdoor: 95° F (35° C) DB / 75° F (24° C) WB Heating at 47°F I Indoor: 70° F (21° C) DB / 60° F (16° C) WB Heating at 47°F I Outdoor. 47° F (8° C) DB / 43° F (6° C) WB Heating at 17° F I Indoor. 70° F (21° C) DB / 60° F (16° C) WB Heating at 17° F I Outdoor. 17° F (-8° C) DB / 15° F (-9° C) WB ** Maximum Capacity is at full speed and performance for INVERTER -driven System. Electrical Requirements Power Supply 208 / 230V, 1-Phase, 60 Hz Breaker Size 15 A OPERATING RANGE Indoor Intake Air Temp. Outdoor Intake Air Temp. Cooling Maximum 90° F (32° C) DB 73° F (23° C) WB , 115° F (46° C) DB Minimum 67° F (19° C) DB 57° F (14° C) WB 14° F (-10° C) DB Heating Maximum 80° F (27° C) DB 67° F (19° C) WB 75° F (24° C) DB 65° F (18° C) WB Minimum 70° F (21° C) DB 60° F (16° C) WB -4° F (-20° C) DB -5° F (-21° C) WB Voltage Indoor - Outdoor S1-S2 AC 208 / 230V Indoor - Outdoor S2-S3 DC ±24V Indoor - Remote Controller MHK1 DC 3V PAR-21 MAAU DC 12V PAR-FL32MA DC 3V Indoor Unit MCA 1 A Blower Motor (ECM) 0.76 F.L.A. Airflow (Quiet - Lo - Med Hi - Super Hi) Cooling 145 - 170 - 237 - 321 - 399 Dry CFM 109 - 134-201 -286-364 Wet CFM Heating 145 - 170 - 237 - 321 - 406 Dry CFM Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Cooling 19 - 22 - 30 - 37 - 45 dB(A) Heating 19 - 22 - 30 - 37 - 43 dB(A) DIMENSIONS UNIT INCHES 1 MM W 31-7/16 / 799 D 9-1/8 / 232 H 11-5/8 / 295 Weight 22 Ibs.7 10 kg External Finish Munsell No. 1.0Y 9.2 / 0.2 Field Drainpipe Size O.D. 5/8" / 15.88 mm Outdoor Unit Compressor DC Inverter -driven MCA 12 A Fan Motor (ECM) 0.50 F.L.A. Sound Pressure Level Cooling 49 dB(A Heating 51 dB(A) DIMENSIONS INCHES / MM W 31-1/2/800 D 11-1/4 / 286 H 21-5/8 / 549 Weight 77 lbs. / 35 kg External Finish Munsell No. 3Y 7.8 / 1.1 Refrigerant Type R410A Refrigerant Pipe Size O.D. Gas Side 3/8" / 9.52 mm Liquid Side 1/4" / 6.35 mm Max. Refrigerant Pipe Length 65 ft. / 20 m Max. Refrigerant Pipe Height Difference 40 ft. / 12 m Connection Method Flared Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. M f• DIMENSIONS: MSZ-GE12NA-8 & MUZ-GE12NA MSZ-GEI 2NA-8 2- 5/16 3/4 7/16x1 Oblong hole Installation plate 31-7/16 30-15/16 1/4 � llllllllll� llllllllll� lllllllll� l l lllllllll� llllllllll� illlllllll� � � I�f1•��IIf1•���� II1NNIINN �11�---m11 Indoor unit 3-1/8 0 8-7/8 I 8-7/8 17 m 1-15/16 24-3/8 5-1/8 11 . 1 2-3/16 2-3/1 1 Unit: inch 7/16x13/16 Oblong hole 3-1/8 m ch A m 13-5/16 Air in 6-1/8 6-1/8 13-9/16 Installation •late m m u> 2-1/8 Wall hole 02-9/16 Pi in Air out /3/1 4-3/8 m 1.5/8 N Drain hose is, a Insulation 01 - 3/8 O.D Liquid line 01/4 19 -11/16 (Flared connection 01/4) Gas line 03/8 16 - 15/16 (Flared connection: 03/8 (GE06/09112NA), 01/2 (GE15/18NA)) Drain hose Insulation e1-1/8 O.D Connected part 05/8 O.D MUZ-GE12NA 7/8 , < handle v Drain hole $1-5/8 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIII 111111111111111111111111111111 IIIIIII IIIIIIIIIIIIIIIIII11111111111111 IIIIIII 111111111111111111111111111111111111111 1111111111111111111111111111111111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Illlllllllllllllllllllilllllllllllllllll uuuuuuunnuuuuu unuunl <,5-15116 11-29 32 19-11/16 c 31-1/2 c 2-23/32 REQUIRED SPACE 29/32 11-1/4 17/32 Unit: inch Basically open 4 inch or more without any obstruction in front and on both sides of the unit. Open two sides of left, right, or rear side. Liquid pipe :1/4 (flared) Gas pipe :3/8 (flared) (GE09/12) 1/2 (flared) (GE75) ,, tvvt.ahrlditectury.org Unitary Small HP ':. AHRI Standard 210/240 C cn4,1,6-IMiep11,,npMl !ib I,, 0w,InAr,Al. Intertek IrtMITSUBISHI ELECTRIC COOLING & HEATING Live Better 1340 Satellite Boulevard Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Toll Free: 800-433-4822 www.mehvac.com FORM# MSZ-GE12NA-8 — MUZ-GE12NA- 201304 Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. How does the sound decrease with distance? sound pressure distance wave drop decrease ... Page 8 of 13 1.0 0.7 r4;) 0.6 0.5 o 0.4 0.3 le 0.2 0.1 0 rILE 2 3 4 5 6 7 8 9 10 Relative distance r1/t 2 1/32 = 1/9 = 0.1111 4 1/42 = 1/16 = 0.0625 5 1/52 = 1/25 = 0.0400 6 1/62 = 1/36 = 0.0278 7 1 /72 = 1 /49 = 0.0204 8 1/82 = 1/64 = 0.0156 9 1 /92 = 1 /81 = 0.0123 10 1/102=1/100 = 0.0100 REVE WEL CODE COMP APPROV JUN 1 0 CIof Tuk BUILDING DI FOR JANCE ED 015 vila 'ISION Sound Level L and the DistanceC RECEIVED ITY OF TUKWILA Distance -related decrease of sound level JUN 4 5 2015 ERMIT CENTER httn://www.sengoielaudio.com/calculator-SoundAndDistance.htm 6/4/201 How does the sound decrease with distance? sound pressure distance wave drop decrease ... Page 9 of 13 Levels of sound pressure and levels of sound intensity decrease equally with the distance from the sound source. Sound power or sound power level has nothing (!) to do with the distance from the sound source. Thinking helps: A 100 watt light bulb has in 1 m and in 10 m distance really always the same 100 watts, which is emitted from the lamp all the time. Watts don't change with distance. Sound is here the sound level, whether it is the sound pressure level or the sound intensity level. tor+ Calculatio Reference distance ri from sound source Sound level Li at reference distance r1 1.00 m or ft 151 dBSPL Another distance r2 from sound source Sound level L2 at another distance r2 40.9 " dBSPL 3.2 m or ft reset calculate I 1 of the aistance r2 where we get the specific sour Sound level Li at reference distance r1 Reference distance from sound source r1 [100 dBSPL 11.00 m Sound level L2 at another distance r2 Another distance from sound source r2 94 dBSPL m reset calculate v Mix c/B5PL MeasccY-ea4 l +es 141 ��cwi C+u4dcor u� t (4BSPL- level 61.-4 3.2-M or elproXrwia_le9,j 10 Fr d level L2. Formulas to calculate the sound level L in dB (sound pressure level or sound intensity level) in dependence of the distance r from a sound source. Sound level L and Distance r LZ = L1— 120 .lo ' `. r2 f2 = '1L1- 211 20 i J1 s\ 2 = Ll — 110 • log —1 7 r22 r1�1—L21'i'. 10- 20 012 b c V L: d BsPt 1),-1 (jeartH.ce. sc I ever a - 1144 1'= retetat e dtclAux 3vf� iv = l\leu) ctiS cc (10-f4 ,n -HAK COO L2 � 51 -1Z0 ))VW 1 Often we talk only of sound level. However, sound pressure as a sound 1, 2 = s 1 _ I . 10.11 1 field size is not the same as sound intensity as a sound energy size. q00137. I PL. http://www. sengpielaudio. com/calculator-SoundAndDistance.htm 6/4/2015 3-12. SOUND PRESSURE LEVELS MSZ-GE24NA OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 ybar) 90 80 70 60 5 4 3 2 NOTCH SPL(dB(A)) LINE COOLING(Rated) 53 •---• HEATING(Rated) 53 CO----0 1111kSik. billikallm.— - _- �a— NC-70 61 NC-601 \a.1614111 Ili 1 Waft gligilligraNC-30 NC.4Oi - 1 I• APPROXIMATE THRESHOLD OF ' HEARING CONTINUOUS NOISE NOISE = = -NC•401 = 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz (2) Outdoor Unit MUZ-GEO9NA2 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 Oar) 90 80 70 60 5 4 NOTCH SPL(dB(A)) LINE COOLING 46 ••—• HEATING 50 O—O MIAMI '-bb� NC-70 -NA 014‘4111d\�� _NC-G01 � NC501 Iffi MW�M NC-40 ii INKS NC-30i _ -NC-I01 APPROXI THRESHOLD OF HEARING FOR CONTINUOUS NOISE N= = - 20 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz WALL UNIT 39-3/8 inch (1m) 31-1/2 inch (0.8 MICROPHONE • NOTE:The sound level is measured in an anechoic room where echoes are few,when compressor stops.The sound may be bigger than displayed level under actual installation condition by surrounding echoes.The sound level can be higher by about 2 dB than the displayed level during cooling and heating operation. MUZ-GE12NA2 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 ybar) 90 80 70 60 50 4 3 2 1 l e>t=(s were AneaSU C).-4 l vri 41061 ULU (T NOTCH: SPL(dB(A)) LINE COOLING 49 • HEATING 51 0 0 4 Eh ‘`.-�‘� AMA. bk\i'l E $ = NC40 I _ _ _N,411.,„ CfiOi MtiiI _ ., NC•�l isi.2.j2 140 MIME.grin - APPROXIMATE TNRESHOLD OF HEARING FOR CONTINUOUS NOISE = - _ _ N470i 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz Due to continuing improvement, above specification may be subject to change without notice. hAC7-(FAIA7-"AR NA_Cn.nc -. NAC7I1,AI t7.(^-CNIA) )AI A\ 11/1ITCIIDICUI CI C/`TDIt`/`ADDADATIAAI PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0064 DATE: 6/5/15 PROJECT NAME: RIVERTON APARTMENTS - BLDG A SITE ADDRESS: 14461 41ST AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: iftw Building Division Public Works El witt, (1-4-K efq, 6,14‘ Fire Prevention Planning Division Structural Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 6/9/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: n 7/6/15 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013