HomeMy WebLinkAboutPermit M15-0071 - EDDIE BAUER - HEAT PUMP AND CONDENSING UNITEDDIE BAUER 660 SOUTHCENTER MALL M15-0071 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 Permit Number: M15-0071 660 SOUTHCENTER MALL Project Name: EDDIE BAUER Issue Date: 2/18/2016 Permit Expires On: 8/16/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940, CARLSBAD, MI, 92013 AMY DIEKEVERS 75 - 60TH ST SW , WYOMING, MI, 49548 CASSNIK CONTRACTING LLC 15 NORTH CENTRAL AVENUE , CANONSBURG, PA, 15317 CASSNCL848CQ Phone: (616) 493-9334 Phone: (724) 941-2055 Expiration Date: DESCRIPTION OF WORK: TENANT IMPROVEMENT - REUSE OF EXISTING INTERIOR HEAT PUMP AND EXTERIOR CONDENSING UNIT. Valuation of Work: $12,789.00 Type of Work: Fuel type: Fees Collected: $363.48 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 • 2012 Permit Center Authorized Signature: 1it'i.tI 0 Date: v I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit , nd agree to the conditions attached to this permit. Signature: /� r Print Name: A MFS S Date: 02/ % 3/ / 6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshal's Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M 19 ' CC 1 I Project No. Date Application Accepted: 1,9161 \'t Date Application Expires: 1' \ l (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: le ?xtt c" PROPERTY OWNER Name: vo5Q Address: -2. -'5 3\ ftr City:s.j .i State: \op‘ Zip:.,SIN CONTACT PERSON — person receiving all project communication Name: Address: nS-_V)..O�,r�� j City: C,1 yState: Zip:1 I 1N Phone: `9t t „qc( jji ax: to// 4_ _ 7 9,2 9 1 Email: 0-91YVAR OcestA\eNN.W3ri M\ , �� King Co Assessor's Tax No.: Suite Number: 7. F or: New Tenant: Yes ❑ „No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 12.. Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: 11AApplicatbns\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan l connected to single duct . Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Pj Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ROR AU ORIZED AGENT: Signature: � .t �c +- Print Name: T l i �� Q(S Mailing Address: (A - J Date: b - `1 t Day Telephone: `Q` �►.�-�0�� still �F-��� State Zip City n:\Applicaliore\Porms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2of2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PermitTRAK PAID $293.58 M15-0071 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $293.58 MECHANICAL $279.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $247.10 TECHNOLOGY FEE $13.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7700 R000.322.900.04.00 0.00 $13.98 $293.58 Date Paid: Tuesday, February 16, 2016 Paid By: CASSNIK CONTRACTING LLC Pay Method: CHECK 003129 Printed: Tuesday, February 16, 2016 10:57 AM 1 of 1 CPSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY PAID $1,948.77 D15-0132 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $1,678.69 DEVELOPMENT $1,678.69 PLAN CHECK FEE I R000.345.830.00.00 0.00 $1,678.69 EL15-0525 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $165.30 ELECTRICAL $165.30 PLAN CHECK FEE R000.345.832.00.00 0.00 $165.30 M15-0071 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $69.90 MECHANICAL $69.90 PLAN CHECK FEE R000.322.102.00.00 0.00 $69.90 PG15-0069 Address: 660 SOUTHCENTER MALL Apn: 9202470010 $34.88 PLUMBING $34.88 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R5493 R000.322.103.00.00 0.00 $34.88 $1,948.77 Date Paid: Tuesday, June 09, 2015 Paid By: PRECISION PERMIT Pay Method: CHECK 13465 Printed: Tuesday, June 09, 2015 1:03 PM 1 of 1 r9SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /l'1 r - Oo 7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project . dd:j� bQ-u' e-k' Type o�spectio , ,'t? c-h, f r icy/ Address: 67° l�(4-f c,4 �C,(f Date Called: Special Instructions: 11 /l't Date Wanted: 3 — a.m. p.m. Requester. Phone No: pproved per applicable codes. L Corrections required prior to approval. OM M ENTS: /1)114- 514.top-€ D -1- -- % r_ e_ (duct— 4I Inspector: Date: i I_ / 3 t /6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD /1 r'0O Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ect: �� 6/6 Typeinspection: Address: 6603o Ck1r ®�a Date Called: +Date Special Instructions: (" ((^ Ct(e6 O"�e�( e.I -1--tro ° .., Wanted. _ 6 a.m. . , . Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: .r& Date: 3 —0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director December 1, 2015 Amy Diekevers Precision Permit Services 75 60th St SW Wyoming, MI 49548 RE: Request for Application Extension Eddie Bauer— 660 Southcenter Mall Dear Ms. Diekevers, This letter is in response to your written request for an extension to Application Number M15-0071. The Building Official has reviewed your letter and considered your request to extend the above referenced application. It has been determined that the City of Tukwila Building Division will be extending your permit application an additional 180 days, through June 9, 2016. If you should have any questions, please contact our office at (206) 431-3670 extension 1. Sincerely, Bill Rambo Permit Technician File: Permit M15-0071 W.\Per,nit Center\Extension Letters\Applications\2015\1Y115-0071 App Extension Letter.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Bill Rambo From: Amy Diekevers <amyd@precisionpermits.com> Sent: Friday, November 20, 2015 11:05 AM To: Bill Rambo Subject: Request for Plan Review Extensions EDDIE BAUER SOUTHCENTER Attachments: EL15-0525.pdf; PG15-0069.pdf; M15-0071.pdf; D15-0132.pdf Importance: High Hi Bill, Per the attached notices, I am requesting plan review approval extensions on all of them. We are scheduled to start construction on 2/1/16. Let me know if this is enough to extend the approvals or if there is something additional I need to do. Thank you, Precision Permit Services 75 60th St SW Wyoming MI 49548 616-493-9334 ph 616-493-9351 fax Request for Extension # 1 , Current Expiration Date: Extension Request: C)--9-/s IApproved for / ,ra days ❑ Denied (provide explanation) Signature/Initials i City of Tukwila Department of Community Development November 4, 2015 AMY DIEKEVERS 75 60TH ST SW WYOMING, MI 49548 RE: Application No. M15-0071 EDDIE BAUER 660 SOUTHCENTER MALL Dear AMY DIEKEVERS: Jim Haggerton, Mayor Jack Pace, Director Permit application M15-0071 for the work proposed at EDDIE BAUER (660 SOUTHCENTER MALL) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 12/09/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0071 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0071 DATE: 06/15/15 PROJECT NAME: EDDIE BAUER SITE ADDRESS: 660 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: As p 6; 74 ��► *NU V11.141t9 Building Division NJ Fire Prevention Public Works Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/16/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 07/14/2015 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CASSNIK CONTRACTING LLC - Home Espanol Contact. Page 1 of 2 Search L&I Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-Z Index Help Ivty Secure 1.,&I Workplace Rights Trades & Licensing CASSNIK CONTRACTING LLC Owner or tradesperson HRABIK, DOUGLAS J Principals HRABIK, DOUGLAS J, PARTNER/MEMBER WA UBI No. 603 584 720 15 NORTH CENTRAL AVENUE CANONSBURG, PA15317 724-941-2055 Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CASSNCL848CQ Effective — expiration 02/18/2016— 02/18/2018 Bond ................ Western Surety Co Bond account no. 62680345 $12,000.00 Received by L&I Effective date 02/18/2016 02/17/2016 Expiration date Until Canceled Insurance ......................... United Specialty Insurance Com $1,000,000.00 Policy no. SI13904A0758902 Received by L&I Effective date 02/18/2016 12/09/2015 Expiration date 12/09/2016 Say.in ................gs No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............... No L&I tax debts are recorded for this contractor license during the previous 6 year period, ut some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603584720&LIC=CASSNCL848CQ&SAW= 2/18/2016 1 B' 142"X20" (2) J R-051 `A' 6 130 1 0 0 r=4 0 42"X2-0"--1 'A' 18" 205 •-0 `A' 10" 0 320 22" 0 0 0 32aL 0 7,7 O 0 0 V 7 7:777 07 1' 'A' 10 " 0 320 32(11. 18"0 iy `A 10"0 7-7 FC .10"0 320 \ :, 'A' 10" 0 320 'A-10" 7- 320 .- 0 I 14"0 12"0 0 0 O A 10 _..__..T._ . 320 O .- HVAC PLAN 1/4" = 1'-0" ABBREVIATIONS SYMBOL LEGEND AC AFF AMP AP BTU CBV CFH CFM CHW CHWR CHWS CLG CO CR CW DB DEMO DIA DIFF DWG DX EAT ELEC ELEV EMS ESP EWB EWT EXH EXIST F FSD FCO FD FD FDC FFE FLR FPM FT GA GAL GC HPH HT HVAC HW HZ ID AIR CONDITION (-ING, -ED) ABOVE FINISHED FLOOR AMPERE (AMP, AMPS) ACCESS PANEL BRITISH THERMAL UNIT CIRCUIT BALANCING VALVE CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CIRCULATING HOT WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING CLEANOUT CONDENSATE RETURN COLD WATER DECIBEL DEMOLITION DIAMETER DIFFUSER DRAWING DIRECT EXPANSION ENTERING AIR TEMPERATURE ELECTRICAL ELEVATION ENERGY MANAGEMENT SYSTEM EXTERNAL STATIC PRESSURE ENTERING WET BULB ENTERING WATER TEMPERATURE EXHAUST EXISTING FAHRENHEIT COMBINATION FIRE/SMOKE DAMPER FLOOR CLEANOUT FIRE DAMPER FLOOR DRAIN FIRE DEPARTMENT CONNECTION FINISHED FLOOR ELEVATION FLOOR FEET PER MINUTE FOOT OR FEET GAGE OR GAUGE GALLONS GENERAL CONTRACTOR GALLONS PER HOUR HORSEPOWER HEIGHT HEATING, VENTILATING, AIR CONDITIONING HOT WATER HERTZ INSIDE DIAMETER INV KW LAT LBS LWB LWT MA MAX M MBIN MISC NA NC NIC NTS OA OBD ORD PH PVC RD REC REL RH RM RPM SA SAN SF SP SPEC ST STD TD TSP TYP V VFD VSD VOL WVTR W/ W/0 WC WCO WT INVERT KILOWATT LEAVING AIR TEMPERATURE POUNDS LEAVING WET BULB LEAVING WATER TEMPERATURE MIXED AIR MAXIMUM THOUSAND BTU'S/HR MINIMUM MISCELLANEOUS NOT APPLICABLE NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW ROOF DRAIN PHASE (ELECTRICAL) POLYVINYL CHLORIDE RETURN AIR ROOF DRAIN RECESSED RELIEF RELATIVE HUMIDITY ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SANITARY SMOKE DAMPER SQUARE FEET STATIC PRESSURE SPECIFICATION STORM STANDARD TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE TYPICAL VOLTS VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE VOLUME VENT THROUGH ROOF WATTS WITH WITHOUT WATER CLOSET WALL CLEANOUT WEIGHT EQUIPMENT TAGS ACCU AHU AHUP BP CDWP CEF CHWP CP CPR CRP CUH DHC ECH EF EHC ES EUH EWC EWH FCU FP B AIR COOLED CONDENSING UNIT AIR HANDLING UNIT AIR HANDLING UNIT PUMP BOOSTER PUMP CONDENSER WATER PUMP CEILING EXHAUST FAN CHILLED WATER PUMP CIRCULATING PUMP CONDENSATE PUMP AND RECEIVER CONDENSATE RETURN PUMP CABINET UNIT HEATER DUCT HEATING COIL ELECTRIC CABINET HEATER EXHAUST FAN ELECTRIC HEATING COIL ELECTRONIC SENSOR ELECTRIC UNIT HEATER ELECTRIC WATER COOLER ELECTRIC WATER HEATER FAN COIL UNIT FAN POWERED VARIABLE AIR VOLUME GWH HU HUH. HWP IH MAU PCWP PHWP PRV REF RF RH RTU SCWP SEP SHWP SP TF USF BOX VA WS GAS WATER HEATER HUMIDIFIER HORIZONTAL UNIT HEATER HEATING WATER PUMP INTAKE HOOD MAKE-UP AIR UNIT PRIMARY CHILLED WATER PUMP PRIMARY HEATING WATER PUMP POWER ROOF VENTILATOR RELIEF EXHAUST FAN RETURN FAN RELIEF HOOD ROOFTOP UNIT SECONDARY CHILLED WATER PUMP SEWAGE EJECTOR PUMP SECONDARY HEATING WATER PUMP SUMP PUMP TRANSFER FAN UTILITY SET FAN VARIABLE AIR VOLUME BOX VERTICAL UNIT HEATER WATER SOFTENER DUCTWORK SUPPLY DUCT UP SUPPLY DUCT DOWN SUPPLY DUCT UP THROUGH ROOF RETURN/RELIEF DUCT UP RETURN/RELIEF DUCT DOWN RETURN/RELIEF DUCT UP THROUGH ROOF EXHAUST DUCT UP EXHAUST DUCT DOWN EXHAUST DUCT UP THROUGH ROOF MANUAL VOLUME DAMPER MOTORIZED DAMPER FIRE DAMPER W/ACCESS PANEL FIRE/SMOKE DAMPER W/ACCESS PANEL SMOKE DAMPER W/ACCESS PANEL DUCT RISE (OR DROP) EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO BE REMOVED 12/12 f 12/12 X 12/12 �x� 12/12 12/12 12/12 f• 12/12 12/12 1 2/1 2 I •C f-12/12 W ri2p2miL ,L 12/12 f f°, 12/12 f FSD IL 12/12 ! f SD 12/12 f fUP (OR DN) f 12/12 SUPPLY AIR TERMINAL RETURN/EXHAUST/TRANSFER AIR TERMINAL VAV BOX ACCESS PANEL THERMOSTAT TEMPERATURE SENSOR SMOKE DETECTOR LONG RADIUS ELBOW SHORT RADIUS ELBOW WITH VANES EQUIPMENT TAG REVISION TRIANGLE CONNECTION TO EXISTING KEY NOTE SPRINKLER HEAD (SEMI -RECESSED) SPRINKLER HEAD (UPRIGHT) SPRINKLER HEAD (FULLY RECESSED) SPRINKLER HEAD (SIDEWALL) DIFFUSER TYPE I NECK SIZE AIRFLOW QUANTITY 8 XXX 1 0 0 GENERAL NOTES A. COORDINATE LOCATIONS OF DIFFUSER GRILLES W/ARCH REFLECTED CEILING PLAN. B. A COMPLETE AIR BALANCE MUST BE COMPLETED PRIOR TO CONSTRUCTION WALK-THRU. SUBMIT COPIES OF TEST & BALANCE REPORT TO LANDLORD, OWNER & ENGINEER. C. ADJUST DISCHARGE PATTERN OF THE DIFFUSER FOR A VERTICAL FLOW. D. REMOVE ALL EXISTING GRILLES, REGISTERS, AND DIFFUSERS AND ASSOCIATED DUCTWORK NOT BEING REUSED. NOTHING TO BE ABANDONED ON ROOF. REFER TO ARCHITECTURAL DEMOLITION PLANS. PROVIDE PROPER PROTECTION UNDER ALL MECHANICAL DUCTWORK. E. CONTRACTOR SHALL COMPLETELY REMOVE FROM THE PREMISES ALL EQUIPMENT, PIPING, DUCTWORK, CONTROLS, CONTROL WIRING, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN ON TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. F. DIFFUSER RUNOUT EQUAL TO DIFFUSER CONNECTION UNLESS OTHERWISE SPECIFIED. G. SPRINKLER HEAD LOCATIONS ARE FOR REFERENCE ONLY. THE FINAL LOCATIONS NEED TO BE INSTALLED PER CODE AND ARE THE RESPONSIBILITY OF THE CONTRACTOR WHO INSTALLS. H. SPRINKLER SUBCONTRACTOR IS TO VERIFY POINT OF CONNECTION TO LANDLORD'S SYSTEM AND SCOPE OF WORK INDICATED PRIOR TO BID. IF INCONSISTENCIES ARE DISCOVERED BETWEEN THESE DOCUMENTS AND THE LANDLORD'S REQUIREMENTS, EDDIE BAUER'S CONSTRUCTION MANAGER IS TO BE NOTIFIED PRIOR TO BID SUBMITTAL. I. SUBCONTRACTOR IS TO VERIFY THE SCOPE OF WORK INDICATED HEREIN PRIOR TO BID. IF INCONSISTENCIES ARE DISCOVERED BETWEEN THESE DOCUMENTS AND THE LANDLORD'S REQUIREMENTS, EDDIE BAUER'S CONSTRUCTION MANAGER IS TO BE NOTIFIED PRIOR TO BID SUBMITTAL. J. EVERY EFFORT HAS BEEN MADE TO ASCERTAIN EXISTING CONDITIONS. DUCTWORK INDICATED HAS BEEN ROUTED AND SIZED TO MAINTAIN CEILING CONDITIONS AND HEIGHTS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLAN. SUB CONTRACTOR IS TO SURVEY THE SPACE TO VERIFY THAT DUCTWORK CAN BE INSTALLED AS INDICATED, PRIOR TO DUCT MANUFACTURE. IF CONFLICTS ARE ENCOUNTERED AS A RESULT OF THIS SURVEY, EDDIE BAUER'S CONSTRUCTION MANAGER IS TO BE NOTIFIED IMMEDIATELY. K. HVAC SUBCONTRACTOR IS TO VERIFY LANDLORD'S EXACT REQUIREMENTS FOR ROOFTOP EQUIPMENT MOUNTING AND SUPPORT PRIOR TO ANY WORK COMMENCING. L. CHANGE FILTERS UPON COMPLETION. M. MARK HVAC UNITS WITH "EDDIE BAUER" AND SPACE NUMBER PER PROJECT STANDARDS AND ANY LANDLORD REQUIREMENTS. MAIN DUCT BRANCH MANUAL VOLUME DAMPER - SPIN -ON BELLNOSE FITTING RIGID ROUND DUCT BRANCH DUCT 4" RIGID DUCT EXTENSION ATTACHED TO DIFFUSER NECK 12'-2" A.F.F. DIFFUSER TYP. DIFFUSER/DUCT CONNECTIONS NO SCALE DUCT MOUNT DIFFUSER KEY NOTES SERVICE AND CLEAN EXISTING (TRANE TWE120) FAN COIL UNIT (FCU-EX) TO BE RELOCATED TO LOCATION SHOWN. REPLACE AND REPAIR UNIT COMPONENTS AS REQUIRED TO MAKE UNIT FULLY FUNCTIONAL, INCLUDING BUT NOT LIMITED TO: FANS, BELTS, BEARINGS, COILS, DAMPERS, DAMPER OPERATORS, MOTORS, OPERATING AND SAFETY CONTROLS. CONTROLS TO BE REPLACED WITH NEW. SEE SPECIFICATION FOR NEW CONTROLS AND CLEANING HVAC SYSTEM. SERVICE AND CLEAN EXISTING (TRANE TWA120) HEATPUMP (HP -EX) TO REMAIN. REPLACE AND REPAIR UNIT COMPONENTS AS REQUIRED TO MAKE UNIT FULLY FUNCTIONAL, INCLUDING BUT NOT LIMITED TO: FANS, BELTS, BEARINGS, COILS, DAMPERS, DAMPER OPERATORS, MOTORS, OPERATING AND SAFTEY CONTROLS. SEE SPECIFICATIONS FOR NEW CONTROLS AND CLEANING HVAC SYSTEM. PROVIDE NEW REMOTE TEMPERATURE SENSOR FOR FCU-EX-1 CONTROL. MOUNT AT 48" A.F.F. IN THE SALES AREA. PROVIDE NEW CONTROLLER FOR FCU-EX-1 CONTROL. MOUNT AT 48" A.F.F. INSTALL DUCT SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR IN RETURN MAIN DUCT. DETECTOR SHALL SHUT DOWN HVAC UNIT UPON DETECTION OF SMOKE. EXHAUST FAN PROVIDED BY ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR TO CONNECT 6"0 DUCT FROM THE EXHAUST FAN THRU THE ROOF TO THE GOOSENECK. SEE DETAIL 3/M1. LOCATE TOILET EXHAUST STACK SO THAT ALL ROOF PENETRATIONS OCCUR AT A MINIMUM OF TEN FEET (10'-0") AWAY FROM ANY MECHANICAL EQUIPMENT INTAKES OR OUTSIDE AIR INTAKE HOODS. USE LANDLORD DESIGNATED ROOFING CONTRACTOR FOR ALL ROOF WORK. PROVIDE 3/4" INSULATED CONDENSATE PIPE FROM CONDENSATE CONNECTION ON UNIT. ROUTE PIPE TO LAV TAILPIECE. ROUTE CONDENSATE PIPING DOWN IN WALL AND TERMINATE WITH CODE APPROVED AIR GAP OVER FLOOR DRAIN. TRAP DRAIN PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE 2" DEEP GALVANIZED SECONDARY DRAIN PAN WITH WET SWITCH. O8 PROVIDE TRANSFER GRILLE OPENING ON BOTH SIDES OF WALL. MOUNT TRANSFER GRILLE ON STOCK ROOM SIDE AS HIGH AS POSSIBLE. MOUNT TRANSFER GRILLE ON SALES SIDE SO TOP EDGE OF TRANSFER GRILLE IS JUST BELOW BOTTOM EDGE OF TRANSFER GRILLE ON STOCK ROOM SIDE. NO LIGHT SHOULD BE ABLE TO PASS THROUGH FROM STOCKROOM TO SALES AT TRANSFER GRILLE LOCATIONS. % COVER RETURN AIR OPENING WITH 1 "X1" WELDED WIRE MESH. 10 REBALANCE FCU-EX TO 3600 CFM SUPPLY AIR, 820 CFM OA. 11 EXTEND AND CONNECT NEW 24"X24" OUTSIDE AIR INTAKE DUCT FROM FCU-EX TO EXISTING OUTDOOR AIR DUCT THRU ROOF. FIELD VERIFY EXACT LOCATION OF EXISTING DUCT. FILE Pernet. na„...111119' 01)11 Plan roViaVi a prc. va is subject to ari d urriiions. f; _ oVa of cy sr:.,,: actin t documents does not authorize the violation of and adopted code or ordinance. Receipt cf approved Ficld Co d conditions is acknowledged: By: Date: DO NOT PLACE ANYTHING ON BACKWRAP WALL EXCEPT VIDEO ARRAY EQUIPMENT. SEE KEYNOTE 2 ON SHEET El. City of Tukwila BUILDING DIVISION EF AM EXHAUST FAN SCHEDULE UNIT TAG EF-1 AREA SERVED RESTROOM MANUFACTURER GREENHECK MODEL NUMBER SP-B110 DRIVE (BELT, DIRECT) DIRECT FAN DATA CFM 100 ESP 0.25 POWER 80W ELECTRICAL V-PH-CY 115/1/60 DISCONNECT DIV. 16 WEIGHT (LBS) 10 REMARKS INTERLOCK WITH TOILET ROOM LIGHTS GRILLE AND DIFFUSER SCHEDULE aft TYPE A B ITEM SUPPLY TRANSFER DESCRIPTION DUCT MOUNT SIDEWALL MANUFACTURER TITUS TITUS MODEL NUMBER TMRA 35OZRL' REMARKS STD. WHITE FINISH STD. WHITE FINISH REVISIONS No change stall ho made to the scope I of work without prior epproval of Tu.kl,viia Building Division_ i 1.T: T i evi_!ons will require a new plan submittal I r r -i may inu'Lde additional plan ',vim!? fees. 0/f. Lc -,anicat a! . Electrical i Piumbing %Gas Piping Ci y of Tukwila F'L.' _`.� • DIVISION RECEIVED CITY OF TUKWILA JUN 0 9 2015 PERMIT CENTER J J Wa z� UJ Ow CO CD 11E1 Project No: MI5-2I24.013 ■■■■■■■■■.■■.■ fili.iis1- 1 �Tri■■.a1 ■ r 1i I za :I■ UMWoAPPUI 1■■'IFI ■■■■■■■■■■■ ARCH: TEC` ■■■ ■■■■■■■■■■■ •■■■■■■■■■■■■■ ■■■■■■■■■■■■■■ •201, N. 00 WW m w z (79 Qz 2 W \V D L. ONAL LL Review Set Issued: 05/06/20 15 Permit Set Issued: 05/26/20 15 Bid Set Issued: 05/26/20 15 Construction Set Issued: Revisions No.: Date: MJB reviewed by: MDB/RLL scale: AS NOTED Sheet Title _D FCC HANICAL PLIANCE PLAN VED 2015 gig ukwila --mtiCillt�! Sheet No. M1 R-051 HVAC SPECIFICATIONS NOTE: MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE LANDLORD. 1. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH ALL APPLICABLE CODES AND THE LANDLORD'S MINIMUM REQUIREMENTS AS STATED HERON, OR OTHERWISE INDICATED BY THE LANDLORD. 2. SEE ARCHITECTURAL GENERAL AND SPECIAL CONDITIONS. CONDITION REQUIREMENTS SHALL APPLY UNLESS OTHERWISE NOTED. 3. ALL WORK SHALL BE PERFORMED AS INDICATED ON DRAWINGS UNLESS FIELD CONDITIONS REQUIRE MINOR CHANGES BE MADE. MINOR CHANGES SHALL BE MADE WITH NO ADDITIONAL COST. 4. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF THE WORK BY OWNER. 5. ACTUAL LOCATIONS OF LANDLORD'S SERVICES MUST BE FIELD VERIFIED. CHANGES TO CONFORM TO LANDLORD'S POINTS -OF -CONNECTION SHALL BE MADE AT NO ADDITIONAL COST. 6. CONTRACTOR SHALL PREPARE AND SUBMIT AS -BUILT DRAWINGS TO OWNER AND LANDLORD. AS -BUILT DRAWINGS SHALL INDICATE ACTUAL MANUFACTURER OF THE EQUIPMENT INSTALLED, THE EXACT LOCATION OF EQUIPMENT WITH CAPACITY. 7. EQUIPMENT, FIXTURES, AND ACCESSORIES SHALL NOT BE SUPPORTED FROM LANDLORD'S CEILING, SOFFIT, NEUTRAL PIERS, PIPING DUCTWORK, METAL ROOF DECK, LATERAL BRACING, BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM STRUCTURE WHICH HAS BEEN APPROVED BY THE LANDLORD FOR SUPPORT. 8. ALL ROOF WORK PENETRATIONS AND REPAIRS SHALL BE TOTALLY PERFORMED BY ONLY THOSE ROOFING CONTRACTORS APPROVED BY THE LANDLORD. 9. INSTALLATION OF ROOF MOUNTED EQUIPMENT SHALL BE COORDINATED WITH THE LANDLORD'S DESIGNATED REPRESENTATIVE. 10. DEFICIENCIES AND NON -CONFORMING ITEMS SHALL BE CORRECTED BY THE CONTRACTOR. FAILURE TO CORRECT SUCH ITEMS SHALL PERMIT THE LANDLORD TO CORRECT SAME AT A COST TO THE CONTRACTOR. 11. INSTALLATIONS OF EQUIPMENT SUCH AS FANS, FLOOR DRAINS, ETC., SHALL CONFORM TO THE LANDLORD'S STANDARD DETAILS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH THE LANDLORD'S MINIMUM STANDARDS. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL PERMITS AND PAYING FOR SAME. HE SHALL INCLUDE IN HIS BID CHARGES FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THE SPACE INCLUDING BUT NOT LIMITED TO LOCAL, COUNTY, OR STATE SERVICE CHARGES AND PERMIT FEES, AND LANDLORD'S UTILITY, AND/OR EQUIPMENT CHARGES. 13. SCOPE OF WORK OF THIS CONTRACT: 13.1. RELOCATE EXISTING FAN COIL UNIT. 13.2. PROVIDE AND INSTALL ALL DUCT WORK, INSULATION, AIR DEVICES, DUCT ACCESSORIES, MATERIAL AND LABOR 13.3. PROVIDE AND INSTALL ALL PIPING, FITTINGS, VALVES, INSULATION AND ACCESSORIES, MATERIAL AND LABOR 13.4. PROVIDE AND INSTALL EXHAUST SYSTEM INDICATED 13.6. PROVIDE ALL EQUIPMENT SUPPORTS AND HANGERS INCLUDING AUXILIARY STEEL REQUIRED ANY STRUCTURAL MODIFICATION TO THE BUILDING STRUCTURE SHALL BE MADE WITH THE WRITTEN APPROVAL OF THE LANDLORD THE T.G.C. MUST COORDINATE THIS WORK WITH A PROFESSIONAL STRUCTURAL ENGINEERED AND OBTAIN ALL REQUIRED CONSTRUCTION DOCUMENTATION FROM SUCH ENGINEER. 13.7. CLEAN AND TEST ALL SYSTEMS HEREIN SPECIFIED. 13.8. PROVIDE BALANCE REPORT PREPARED BY INDEPENDENT AIR BALANCE CONTRACTOR. 13.9. WARRANTY ALL WORK HEREIN SPECIFIED, FOR A PERIOD OF ONE YEAR. 14. MATERIALS: 14.1. ALL MATERIALS SHALL BE NEW AND OF RECOGNIZED COMMERCIAL QUALITY. USED MATERIALS SHALL NOT BE PERMITTED. 14.2. DUCTWORK: • SHALL BE GALVANIZED SHEET METAL, FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF SMACNA - "HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE". DUCTWORK 18" WIDTH AND LARGER SHALL BE CROSS -BROKEN OR RIBBED AND STIFFENED, SO THAT IT WILL NOT "BREATHE", RATTLE, VIBRATE OR SAG. 14.3. FLEXIBLE DUCTWORK: • SHALL HAVE IMPERVIOUS INNER CORE WITH WIRE REINFORCEMENT. THE INNER DUCT SHALL BE COVERED WITH 1-1/2" FIBERGLASS INSULATION WITH A POLYETHYLENE VAPOR -PROOF JACKET. FLEXIBLE DUCT SHALL BE UL-181-LISTED, CLASS 1, AND SHALL MEET ALL LOCAL CODES. • ADJUSTABLE STAINLESS STEEL OR NYLON STRAPS SHALL BE USED TO SECURE DUCT FITTINGS AND EQUIPMENT. A SECOND BAND SHALL BE APPLIED OVER THE JACKET TO MAINTAIN THE VAPOR BARRIER. • FITTINGS TO CONNECT THE FLEX DUCT TO THE TRUNK DUCT SHALL BE DESIGNED TO TWIST INTO THE TRUNK DUCT AND SHALL HAVE BUTTERFLY -TYPE VOLUME DAMPER. FITTING SHALL EXTEND INTO THE DUCT TO PROVIDE SOME AIR SCOOP DEVICE FOR AIRFLOW. • DUCT SHALL BE THE PRODUCT OF AN ESTABLISHED MANUFACTURER OF SUCH PRODUCTS AND EQUIVALENT TO CERTAINTEED - MODEL G-25, WIREMOLD - WGC, OR PPG - GLOSSFLEX. 14.4. DUCT INSULATION: • ALL SUPPLY DUCTS SHALL BE INSULATED EXTERNALLY, UNLESS OTHERWISE NOTED. • INTERNAL INSULATION SHALL BE 1" DUCT LINER WITH K FACTOR OF 2.6 AT 100 DEG F AND ACCEPTABLE FOR VELOCITY UP TO 2500 FPM. • INSULATION ON THE EXTERIOR OF THE DUCT SHALL BE 1" DUCT WRAP WITH A VAPOR PROOF JACKET OF ALUMINUM FOIL OR FOIL-SCRIM-KRAFT PAPER HAVING UL LABEL. DENSITY OF WRAP SHALL BE 1-1/2 LB/CF. • RETURN DUCT SHALL BE INSULATED WITH 1/2" DUCT LINER FOR SOUND CONTROL. ALL INSULATION AND ACCESSORIES SHALL BE UL LABELED FOR FIRE AND SMOKE RATINGS. INSULATION SHALL BE EQUAL TO PRODUCTS MANUFACTURED BY CERTAINTEED. • INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE MANUFACTURER. 14.5. FIRE DAMPER: • SHALL BE PROVIDED AS INDICATED OR REQUIRED BY LOCAL AUTHORITY, TO MEET THE REQUIREMENTS OF NFPA 90A. DAMPERS SHALL BE INTERLOCKING BLADE TYPE WITH UL LABEL, WITH OPEN AREA EQUAL TO THE CLEAR DIMENSION OF THE ADJACENT DUCTWORK. • ACCESS DOOR SHALL BE PROVIDED IN THE DUCTWORK FOR MAINTENANCE OF THE DAMPER. • DAMPER SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS OF SMACNA - LOW VELOCITY STANDARDS. 14.6. AIR DEVICES: • CEILING DIFFUSERS SHALL HAVE FRAME STYLE COMPATIBLE WITH TYPE OF CEILING USED. IN GENERAL, DIFFUSERS SHALL BE SUITABLE FOR TEE -BAR CEILING. THE FACE PLATE SHALL HAVE TURNED UP EDGES AND BE OF THE SAME NOMINAL SIZE AS THE CEILING MODULE. • DIFFUSER SHALL BE CAPABLE OF DELIVERING 1-WAY, 2-WAY, 3-WAY OR 360 DEG HORIZONTAL CEILING PATTERN AND BE ADJUSTABLE TO OBTAIN A DOWN AIR PATTERN. DIFFUSERS MUST HAVE HIGH ANTI -SMUDGE CHARACTERISTICS. • RETURN AIR UNITS SHALL MATCH THE SUPPLY DIFFUSERS. DEVICES ARE TO BE FURNISHED IN STANDARD WHITE FINISH, TO BE PAINTED TO MATCH ADJACENT SURFACES IN THE FIELD. 14.7. PIPING AND FITTINGS: SERVICE: CONDENSATE DRAINPIPE MATERIAL: COPPER TYPE "L" JOINTS: SOLDERED FITTINGS: WROUGHT COPPER 15. EQUIPMENT: • HVAC UNIT(S): EXISTING FAN COIL UNIT TO BE RELOCATED AND REUSED. • THERMOSTAT: PROVIDE ONE HEATING/COOLING THERMOSTAT WITH REMOTE SENSOR TO CONTROL THE OPERATION OF EACH FAN COIL UNIT. MOUNT THERMOSTAT (CONTROLLER) AT 4'-0" A.F.F. IN THE OFFICE. SEE SHEET M-1 FOR APPROXIMATE LOCATION. CONTROLS SHALL BE COMPATIBLE WITH LANDLORDS SYSTEM. • EXHAUST FAN EF-1&2: FURNISH AND INSTALL EXHAUST FAN AS SCHEDULED. 16. EXECUTION: 16.1. GENERAL: • ACCESSIBILITY - ALL EQUIPMENT SHALL BE INSTALLED IN SUCH A WAY THAT ALL COMPONENTS REQUIRING ACCESS ARE LOCATED AND INSTALLED THAT THEY MAY BE SERVICED, RESET, REPLACED, OR RECALIBRATED, ETC., BY SERVICE PEOPLE WITH NORMAL SERVICE TOOLS AND EQUIPMENT. • WORK BY OTHER TRADES - CUTTING, PATCHING, FURRING, PAINTING, ELECTRICAL, PLUMBING, ETC., SHALL BE DONE BY THE AFFECTED TRADE AT THIS CONTRACTOR'S EXPENSE FOR THE CHANGES REQUIRED IN WORK ALREADY INSTALLED OR WORK REQUIRED BY OTHER TRADES FOR CHANGES MADE BY THIS CONTRACTOR IN TYPE OR SIZE OF EQUIPMENT PURCHASED. • WORK NOT INCLUDED - POWER WIRING, INCLUDING FINAL CONNECTIONS, IS BY THE ELECTRICAL CONTRACTOR. THIS CONTRACTOR SHALL INSTALL ALL MOTORS, AND FURNISH THE STARTING EQUIPMENT TO THE ELECTRICAL CONTRACTOR' FOR INSTALLATION. CONTROL WIRING, INCLUDING 115V FROM POWER SOURCE, CONDUIT, AND SWITCHES SHALL, LIKEWISE, BE FURNISHED BY THE ELECTRICAL CONTRACTOR. • CONTROL DEVICES, THERMOSTATS, INTERLOCKS, ETC. SHALL BE FURNISHED BY THIS CONTRACTOR WITH WIRING DIAGRAMS AND INSTRUCTIONS, TO THE ELECTRICAL CONTRACTOR FOR INSTALLATION, UNLESS SPECIFICALLY OTHERWISE INDICATED ON THE PLANS. • EARLY START-UP - THIS CONTRACTOR SHALL SEE THAT THE. MECHANICAL EQUIPMENT IS POWERED NO LATER THAN 3 WEEKS PRIOR TO CONSTRUCTION COMPLETION SO THAT FINAL BALANCING AND TESTING CAN BE STARTED. • CLEANING AND PAINTING - THOROUGHLY CLEAN ALL EQUIPMENT AND REMOVE ALL TRASH, CARTONS, ETC., FROM THE AREA. MAKE ANY NECESSARY CORRECTIONS OR REPAIR/REPLACE ANY DAMAGED MATERIALS OR EQUIPMENT. LEAVE THE ENTIRE SYSTEM IN A THOROUGHLY CLEAN AND ORDERLY MANNER. • ANY FINISHED SURFACES THAT HAVE BEEN SCRATCHED OR DISCOLORED SHALL BE TOUCHED UP OR REPAINTED WITH PAINT TO MATCH THE ORIGINAL COLOR. IF ANY PART HAS BENT, BROKEN, OR OTHERWISE DAMAGED, IT SHALL BE REPLACED PRIOR TO PROJECT CLOSE OUT. • ALL METAL ITEMS INSIDE THE BUILDING SUBJECT TO RUSTING, AND ALL FERROUS METAL EXPOSED TO THE WEATHER, SHALL BE GIVEN ONE COAT OF RUST PREVENTIVE PRIMER AS SOON AS INSTALLED. 16.2. EQUIPMENT: • CONNECT THE REQUIRED DRAIN FROM THE DRAIN PAN TO THE NEAREST ACCEPTABLE OPEN SITE DRAIN, AS DIRECTED BY THE LANDLORD. PROVIDE DEEP SEAL TRAP IN DRAIN LINE AT CONNECTION TO THE DRAIN PAN. SLOPE DRAIN LINE AS MUCH AS IS PRACTICAL. • MAKE ELECTRICAL CONNECTION, TAKING CARE THAT THESE DO NOT BLOCK ACCESS TO ANY PART OF THE EQUIPMENT REQUIRING SERVICE. • CHECK ALL BEARING FOR PROPER LUBRICATION BEFORE STARTING THE UNIT. ADJUST THE VARIABLE PITCH PULLEY FOR THE PROPER FAN SPEED. INSTALL FILTERS, FOR COMPLETE INSTALLATION. • PAINT UNIT AS DIRECTED BY THE LANDLORD. STENCIL EDDIE BAUER AND SPACE NUMBER ON TWO SIDES OF THE UNIT IN 2" HIGH LETTERS. 16.3. DUCTWORK: • LOW PRESSURE DUCTWORK AND FITTINGS SHALL BE MADE TIGHT FOR MINIMUM AIR LEAKAGE. DUCT TAPE SHALL NOT BE USED TO SEAL JOINTS, TO MAKE TRANSITIONS OR FOR AND OTHER REASON ON THE OUTSIDE OF WRAPPED INSULATION. INSTALL DUCTWORK AS HIGH AS POSSIBLE. • PROVIDE TURNING VANES AT ALL CHANGES IN DIRECTION. PROVIDE SPLITTER DAMPERS AT BRANCH CONNECTIONS SERVING MORE THAN ONE DIFFUSER. • PROVIDE VOLUME CONTROL DAMPERS AND BALANCING DEVICES AS REQUIRED TO DISTRIBUTE THE AIR AS INDICATED ON THE PLAN. NOTE: DIMENSIONS INDICATED ON THE PLAN ARE INSIDE CLEAR DIMENSIONS. 16.4. FLEXIBLE DUCTWORK: • DUCTWORK SHALL BE LIMITED IN LENGTH TO THAT NECESSARY TO MAKE CONNECTIONS BETWEEN TRUNK DUCTS AND AIR DEVICES. THIS SHALL NOT EXCEED 3'-0". • ALL DUCT SHALL BE FULLY STRETCHED OUT TO REDUCE RESISTANCE. • CONNECTIONS TO FITTINGS OR AIR DEVICES SHALL BE MADE WITH STAINLESS STEEL BANDS. THE INNER LINER SHALL BE CLAMPED TIGHT WITH THE BAND, THEN THE INSULATION AND JACKET PULLED UP TIGHT AGAINST THE DUCT OR AIR DEVICE AND SECURED WITH A SECOND BAND OR STRAP. INSTALLATION SHALL BE AS RECOMMENDED BY THE DUCT MANUFACTURER. SUPPORT THE FLEXIBLE DUCT WITH ADEQUATE HANGERS TO RELIEVE STRAIN ON ANY FITTING. UNNECESSARY BENDS, SAGS, TWISTS, ETC., WILL NOT BE ALLOWED. 16.5. DUCT INSULATION: • ALL PORTIONS OF DUCT DESIGNATED TO RECEIVE DUCT LINER SHALL BE COMPLETELY COVERED WITH LINER. TRAVERSE JOINTS SHALL BE NEATLY BUTTED AND THERE SHALL BE NOT INTERRUPTIONS OR GAP • DUCT LINER SHALL BE CUT INSURE OVERLAPPED AND COMPRESSED LONGITUDINAL CORNER JOINTS. • FASTENERS SHALL START WITH IN 3" OF THE UPSTREAM TRAVERSE EDGES OF THE LINER AND 3" FROM THE LONGITUDINAL JOINTS AND SHALL BE SPACED AT A MAXIMUM OF 12" O.C. AROUND THE PERIMETER OF THE DUCT. ELSEWHERE THEY SHALL BE A MAXIMUM OF 18" 0.C., EXCEPT THAT THEY SHALL BE PLACED NOT MORE THAN 6" FROM A LONGITUDINAL JOINT OF THE LINER OR 12" FROM A CORNER BREAK. • DUCT WRAP SHALL BE INSTALLED IN A NEAT AND COMPETENT MANNER, WITH ALL EDGES NEATLY COVERED WITH APPROVED METALLIC DUCT TAPE TO VAPOR -PROOF ENTIRE DUCT. LAPS AND JOINTS SHALL BE SECURED WITH INSULATION STAPLES AND THE COVERED WITH APPROVED TAPE. 16.6. AIR DEVICES: • INSTALL ALL GRILLES, REGISTERS AND DIFFUSERS FLUSH WITH THE SURFACE AND LEVEL OR STRAIGHT WITH OTHER CEILING FEATURES. MOUNT DIFFUSERS IN THE CENTER OF THE INDICATED CEILING TILE. • SUPPORT THE REGISTER FROM THE DUCT AT THE PROPER LEVEL TO HOLD IT SNUG AGAINST THE CEILING. • ALL ROOF PENETRATIONS SHALL BE INSTALLED PER THE LANDLORD'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO FAMILIARIZE HIMSELF WITH THE REQUIREMENTS OF THE LANDLORD. 18. TEMPERATURE CONTROLS: • FURNISH AND INSTALL, UNLESS NOTED OTHERWISE, ALL THERMOSTATS, SENSORS, CONTROLLERS, RELAYS, CONTACTORS, DAMPERS, ACTUATORS, TUBING, CONTROL WIRING AND ALL OTHER ITEMS AND MATERIALS NECESSARY FOR A COMPLETE AND PROPERLY OPERATING TEMPERATURE CONTROL SYSTEM AS SPECIFIED BELOW. ALL THERMOSTATS AND OTHER CONTROL COMPONENTS SHALL BE HONEYWELL, OR APPROVED EQUAL, UNLESS SPECIFIED OTHERWISE. ALL CONTROL WIRING SHALL BE BY MECHANICAL CONTRACTOR AND SHALL BE INSTALLED IN CONDUIT. SEQUENCE OF OPERATION: FCU/HP, SPLIT SYSTEM HEAT PUMP WITH SUPPLEMENTAL ELECTRIC HEAT: . . . 1. 2. 3. 4. 5. 6. COOLING CYCLE - OCCUPIED HOURS: UPON A RISE IN SPACE TEMPERATURE ABOVE THE OCCUPIED COOLING SETPOINT OF THE THERMOSTAT, THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FAN AND RETURN/RELIEF FAN SHALL OPERATE CONTINUOUSLY. THE OUTDOOR AIR DAMPER SHALL BE OPEN TO THE MINIMUM POSITION. HEATING CYCLE - OCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE OCCUPIED HEATING SETPOINT OF THE THERMOSTAT, THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. UPON A FURTHER CALL FOR HEAT, THE SUPPLEMENTAL ELECTRIC HEATING COIL SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FAN AND RETURN/RELIEF FAN SHALL OPERATE CONTINUOUSLY AND THE OUTDOOR AIR DAMPER SHALL BE OPEN TO THE MINIMUM POSITION. COOLING CYCLE - UNOCCUPIED HOURS: UPON A RISE IN SPACE TEMPERATURE ABOVE THE UNOCCUPIED COOLING SETPOINT OF THE THERMOSTAT, THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FAN AND RETURN/RELIEF FAN SHALL CYCLE AS REQUIRED AND THE OUTDOOR AIR DAMPER SHALL BE CLOSED. HEATING CYCLE - UNOCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE UNOCCUPIED HEATING SETPOINT OF THE THERMOSTAT, THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. UPON A FURTHER CALL FOR HEAT, THE SUPPLEMENTAL ELECTRIC HEATING COIL SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FAN AND RETURN/RELIEF FAN SHALL CYCLE AS REQUIRED AND THE OUTDOOR AIR DAMPER SHALL BE CLOSED. HEATING CYCLE - UNOCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE UNOCCUPIED HEATING SETPOINT OF THE THERMOSTAT, THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. THE SUPPLY FAN AND RETURN/RELIEF FAN SHALL CYCLE AS REQUIRED AND THE OUTDOOR AIR DAMPER SHALL BE CLOSED. ECONOMIZER CYCLE: WHEN, UPON A CALL FOR COOLING, THE OUTDOOR AIR ENTHALPY IS BELOW THE RETURN AIR ENTHALPY, THE REFRIGERATION SYSTEM OPERATION SHALL BE CONTROLLED BY THE ECONOMIZER. THE ECONOMIZER SHALL MODULATE THE OUTDOOR AIR AND RETURN AIR DAMPERS IN ORDER TO INTRODUCE UP TO 100% OUTDOOR AIR TO SATISFY THE COOLING LOAD IN THE SPACE. IF THE COOLING EFFECT OF THE OUTDOOR AIR IS NOT SUFFICIENT TO COOL THE SPACE, THE REFRIGERATION SYSTEM SHALL CYCLE AS REQUIRED TO SUPPLEMENT THE ECONOMIZER. SPRINKLER SPECIFICATIONS THE WORK CONSISTS OF: • FURNISHING ALL LABOR, MATERIALS, TOOLS, EQUIPMENT SERVICES AND SUPERVISION REQUIRED TO INSTALL, TEST AND PLACE IN SERVICE A COMPLETE FIRE PROTECTION SYSTEM IN STRICT ACCORDANCE WITH THIS SPECIFICATION AND APPLICABLE DRAWINGS. • NEW SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), INDUSTRIAL RISK INSURANCE (IRI), LANDLORD'S INSURANCE UNDERWRITER AND THE LOCAL AUTHORITIES HAVING JURISDICTION. • TESTING OF SPRINKLER SYSTEM SHALL BE ACCORDING TO LOCAL CODES AND MUST BE WITNESSED BY LANDLORD'S REPRESENTATIVE AND/OR REPRESENTATIVE OF LOCAL FIRE MARSHAL'S OFFICE. CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS, PRIOR TO SUBMITTING A BID. SYSTEM SHALL BE HYDRAULICALLY VERIFIED BASED ON THE FOLLOWING COVERAGE, SUBJECT TO THE APPROVAL OF DESIGN BY LANDLORD'S INSURANCE UNDERWRITER AND LOCAL CODES. • COVERAGE SHALL BE BASED ON NET LEASED SPACE. • MINIMUM DENSITY: 0.20 GPM/SF OVER MOST REMOTE 2500 SF • MAXIMUM COVERAGE/HEAD: 130 SF • MINIMUM COVERAGE/HEAD: 90 SF • MINIMUM OPERATING PRESSURE FOR ANY SPRINKLER SHALL NOT BE • LESS THAN 7 PSI; MAXIMUM DISCHARGE PRESSURE USED AT STARTING POINT SHALL NOT EXCEED 60 PSI. CONTRACTOR SHALL PREPARE DRAWINGS TO LOCATE HEADS SHOWN ON PLAN AND SHALL BE RESPONSIBLE FOR THE COST OF ALL PERMITS AND FEES. SPRINKLER MAINS AND BRANCHES: • PIPING MATERIAL: BLACK STEEL, SCHEDULE 40 OR LIGHTWEIGHT • SPRINKLER PIPE, SCHEDULE 10, ASTM A 135 (IF ALLOWED BY LANDLORD AND LOCAL AUTHORITIES) • FITTINGS: THREADED, CLASS 175. MECHANICAL COUPLINGS AND TEES OF A ROLLED GROOVED TYPE WILL BE ACCEPTED (IN LIEU OF THREADED) IF BOTH U.L. AND FIRE MARSHAL LISTED AND APPROVED. • INSTALLATION: ALL SPRINKLER PIPING SHALL BE CONCEALED UNLESS OTHERWISE INDICATED. ALL PIPING SHALL BE LOCATED TO AVOID INTERFERENCE WITH ALL OTHER ELEMENTS ABOVE CEILINGS, ETC. • SUPPORT ALL HORIZONTAL PIPING AT NOT GREATER THAN 10 FOOT INTERVALS, EXCEPT PIPES OF SIZE 1-1/2" AND LARGER WHICH HALL BE SUPPORTED AT NOT GREATER THAN 15 FOOT INTERVALS, WITH APPROVED SWIVEL SPLIT RING HANGERS WITH ROD SUPPORTS AND SWAY BRACES AT EVERY THIRD HANGER. • ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT IT CAN BE THOROUGHLY DRAINED, AND WHERE PRACTICAL, ARRANGED TO DRAIN TO THE MAIN VALVE. SPRINKLER HEADS: • ALL SPRINKLER HEADS IN AREAS WITH FINISHED DRYWALL CEILINGS SHALL BE CONCEALED TYPE, 165 DEG RATED, MATTE WHITE MODEL G1 AS MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO. INC OR APPROVED EQUAL. • EXTENDED COVERAGE SIDEWALL SPRINKLER HEADS SHALL BE USED IN THE HIGHER CEILING OF THE STOREFRONT AND CENTER OF STORE. SPRINKLER HEAD SHALL BE MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO., INC OR APPROVED EQUAL. • SPRINKLER HEADS IN AREAS WITH LAY -IN CEILINGS SHALL BE SEMI -RECESSED TYPE, 165 DEG RATED, CHROME PLATED HEAD WITH ESCUTCHEON COLOR TO MATCH CEILING COLOR, MODEL G AS MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO. INC OR APPROVED EQUAL. • SPRINKLER HEADS IN AREA OF NO CEILING SHALL BE MODEL G CHROME PLATED UPRIGHT AS MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO. INC. OR APPROVED EQUAL. ALL SPRINKLER HEADS SHALL BE 1/2" ORIFICE, RATED AT 165 DEGREES WITH A `K-FACTOR' OF 5.65. • ALL SPRINKLER HEADS THAT ARE TO REMAIN AND BE REUSED SHALL BE PROTECTED DURING CONSTRUCTION AND CLEANED THOROUGHLY TO INSURE THAT THEY ARE CLEAR OF PAINT AND DEBRIS AND ARE IN GOOD WORKING CONDITION, PRIOR TO PROJECT CLOSEOUT. • SPRINKLER HEADS IN WOOD CEILINGS SHALL BE PROVIDED WITH COVERS THAT MATCH THE SURROUNDING FINISH. • ALL SPRINKLER HEADS SHALL BE INSTALL IN ACCORDANCE TO NFPA 13 AND ALL LOCAL CODES THAT APPLY. 7. UPON COMPLETION OF THE SYSTEM, THE INSTALLATION CONTRACTOR SHALL PROVIDE A MATERIAL TEST AND CLARIFICATION FORM TO THE BUILDING DEPARTMENT, THE FIRE MARSHALL, LANDLORD'S CONSTRUCTION COORDINATOR AND LANDLORD'S INSURANCE CARRIER CERTIFYING SATISFACTORY COMPLETION OF THE SPRINKLER SYSTEM INSTALLATION IN ACCORDANCE WITH APPROVED PLANS, CODES, PROCEDURES AND SPECIFICATIONS. • ALTERATIONS TO THE AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE APPROVED UNDER A SEPARATE PERMIT FROM THE FIRE PREVENTION SECTION. QUICK RESPONSE TYPE HEADS SHALL BE USED. PLANS, PERMIT APPLICATION AND FEES SHALL BE SUBMI I I LD BY THE MALL APPROVED SPRINKLER CONTRACTOR AND PERMIT APPROVAL SHALL BE OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE PROTECTION SYSTEM. PLUMBING SPECIFICATIONS NOTE: MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE OWNER'S REPRESENTATIVE. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS OF THE LANDLORD. 1. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH ALL APPLICABLE CODES AND THE LANDLORD'S MINIMUM REQUIREMENTS AS STATED HEREIN, OR OTHERWISE INDICATED BY THE LANDLORD. 2. SEE ARCHITECTURAL GENERAL AND SPECIAL CONDITIONS. CONDITION REQUIREMENTS SHALL APPLY UNLESS OTHERWISE NOTED. 3. ALL WORK SHALL BE PERFORMED AS INDICATED ON DRAWINGS UNLESS FIELD CONDITIONS REQUIRE MINOR CHANGES BE MADE. MINOR CHANGES SHALL BE MADE WITH NO ADDITIONAL COST. 4. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF THE WORK BY OWNER. 5. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS BID. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. 6. THE LANDLORD PROVIDES FOR CONNECTION TO WASTE AND VENT AND DOMESTIC WATER SYSTEMS. 7. ACTUAL LOCATIONS OF EXISTING SERVICE STUBS MUST BE FIELD VERIFIED. CHANGES TO CONFORM TO ACTUAL POINTS -OF -CONNECTION SHALL BE MADE AT NO ADDITIONAL COST. 8. CONTRACTOR SHALL PREPARE AND SUBMIT AS -BUILT DRAWINGS TO OWNER AND LANDLORD. 9. AS -BUILT DRAWINGS SHALL INDICATE ACTUAL MANUFACTURER OF THE EQUIPMENT INSTALLED, THE EXACT LOCATION OF EQUIPMENT WITH CAPACITY. 10. EQUIPMENT, FIXTURES, AND ACCESSORIES SHALL NOT BE SUPPORTED FROM CEILING, SOFFIT, NEUTRAL PIERS, PIPING, DUCTWORK, METAL ROOF DECK, LATERAL BRACING, BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM STRUCTURE WHICH HAS BEEN APPROVED BY THE LANDLORD FOR SUPPORT. 11. ALL ROOF WORK PENETRATIONS AND REPAIRS SHALL BE TOTALLY PERFORMED BY ONLY THOSE ROOFING CONTRACTORS APPROVED BY THE LANDLORD. CONTRACTOR SHALL EMPLOY THOSE ROOFING CONTRACTORS APPROVED BY THE LANDLORD FOR ALL ROOF REQUIRED BY THE TENANT'S APPROVED DESIGN. 12. DEFICIENCIES AND NON -CONFORMING ITEMS SHALL BE CORRECTED BY THE CONTRACTOR. FAILURE TO CORRECT SUCH ITEMS SHALL PERMIT THE LANDLORD TO CORRECT SAME AT A COST TO THE CONTRACTOR. 13. INSTALLATIONS OF EQUIPMENT SUCH AS FLOOR DRAINS, WATER HEATERS, ETC., SHALL CONFORM TO THE LANDLORD'S STANDARD DETAILS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH THE LANDLORD'S MINIMUM STANDARDS. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL PERMITS AND PAYING FOR SAME. HE SHALL INCLUDE IN HIS BID CHARGES FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THE SPACE INCLUDING BUT NOT LIMITED TO LOCAL, COUNTY, OR STATE SERVICE CHARGES AND PERMIT FEES, AND LANDLORD'S UTILITY, AND/OR EQUIPMENT CHARGES. 15. SCOPE OF WORK: • WORK INCLUDES FURNISHING ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST, AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS AND SYSTEMS IN SERVICE. 15.1. SOIL, WASTE AND VENT SYSTEM 15.2. DOMESTIC WATER SYSTEM 15.3. DOMESTIC WATER HEATER 15.4. PLUMBING FIXTURES AND TRIM 15.5. MISCELLANEOUS STEEL WORK, FLOOR AND WALL SLEEVES, SLOTS AND INSERTS, PLATES, SUPPORTS, AND HANGERS 15.6. ALL OTHER PLUMBING ITEMS INDICATED ON THE DRAWINGS, SPECIFIED HEREIN OR NEEDED FOR A COMPLETE AND FUNCTIONAL PLUMBING INSTALLATION IN ACCORDANCE WITH ALL PERTINENT CODES AND REGULATIONS. 15.7. CLEANING AND TESTING OF ALL SYSTEMS 15.8. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR 16. MATERIALS: 16.1. SANITARY DRAIN, WASTE, AND VENT SHALL BE: • SOIL AND WASTE UNDER FLOOR - SERVICE WEIGHT CAST IRON, HUB AND SPIGOT SOIL PIPE AND FITTINGS, COATED INSIDE AND OUT, FED SPEC WW-P-401. JOINTS DOUBLE SEAL COMPRESSION -TYPE GASKETS, EQUAL TO TY-SEAL. • SOIL, WASTE, AND VENT, ABOVE FLOOR - HUBLESS CAST IRON PIPE AND FITTINGS, COATED INSIDE AND OUT, CIPI-301. JOINTS STAINLESS STEEL SHIELD AND CLAMP WITH NEOPRENE SEALING SLEEVE. • OR AS APPROVED BY THE LOCAL ADMINISTRATIVE AUTHORITY. • AT THE CONTRACTOR'S OPTION SCHEDULE 40PVC-DWV. 16.2. DOMESTIC WATER PIPING SHALL BE: • TYPE L COPPER, HARD DRAWN, FEDERAL SPECIFICATION WW-T-799 AND WROUGHT COPPER FITTINGS, 95/5 SOLDER. (LEAD FREE) 16.3. PIPING INSULATION • INSULATE ALL DOMESTIC WATER PIPING AND ALL HORIZONTAL WASTE PIPING ABOVE TENANT SPACES. • INSULATE DOMESTIC HOT WATER PIPING AND P-TRAP BELOW LAVATORY TO PROVIDE HANDICAPPED ACCESSIBILITY. • DOMESTIC WATER PIPING SHALL BE COVERED WITH 1/2" THICK GLASS FIBER COLD WATER PIPE INSULATION WITH VAPOR BARRIER AND ALL SERVICE J ACKET. • HORIZONTAL WASTE PIPING SHALL BE COVERED WITH 1" THICK GLASS FIBER INSULATION WITH VAPOR BARRIER AND ALL SERVICE JACKET. • GLASS FIBER INSULATION SHALL BE OF THE TYPE HAVING A 4.0 LB DENSITY AND A K-FACTOR OF 0.25. ALL EXPOSED AND CONCEALED INSULATED PIPING TO HAVE AN ALL- SERVICE JACKET SIMILAR TO OWENS-CORNING FIBERGLASS ASJ25 WITH SELF SEALING LAP AND JOINT SEALING STRIPS. • AT THE CONTRACTOR'S OPTION AND WITH THE PERMISSION OF THE LANDLORD, CONTRACTOR MAY PROVIDE PRE -FORMED PIPE INSULATION OF CLOSED CELL ELASTOMERIC FOAM. 16.4. DRAINAGE ACCESSORIES: • FLOOR DRAIN SHALL BE WADE W-1100 CAST IRON FLOOR DRAIN WITH FLANGE, INTEGRAL REVERSIBLE CLAMPING COLLAR AND 7" DIAMETER NICKEL BRASS STRAINER. • PROVIDE CAST IRON P-TRAP AT OUTLET OF EACH FLOOR DRAIN. INSTALL TOP OF FLOOR DRAIN 1/16" BELOW FINISHED FLOOR. • FLOOR CLEANOUTS SHALL BE WADE W -7030 CAST IRON WITH ADJUSTABLE HOUSING, FERRULE WITH COUNTERSUNK BRASS PLUG AND ROUND SECURED NICKEL -BRASS SCORIATED TOP. ■ WALL CLEANOUT SHALL BE WADE W-8450 CLEANOUT FERRULE WITH BRASS PLUG AND ROUND FRAME WITH SMOOTH NICKEL BRASS SECURED ACCESS COVER. 16.5. WATERHAMMER ARRESTORS SHALL BE PROVIDED ON ALL HOT AND COLD WATER LINES, AT INDIVIDUAL FIXTURES AND OTHER SUCH LOCATIONS TO BRING WATER SYSTEM IN CONFORMANCE WITH PLUMBING AND DRAINAGE INSTITUTE STANDARD PDI-WH2O1. ACCEPTABLE MANUFACTURERS - WADE SHOKSTOP, JOSAM ABSORPTION, OR SMITH -HYDRATROL. • IN LIEU OF MANUFACTURED WATERHAMMER ARRESTORS, CONTRACTOR MAY PROVIDE 12" HIGH AIRCHAMBERS AT EACH SUPPLY. 16.6. TRAP PRIMER VALVE- JOSAM NO. 88250. EXTEND AND CONNECT 1/2" TRAP PRIMER PIPING TO FLOOR DRAIN CONNECTION. COORDINATE ROUTING IN FIELD. ■ MANUFACTURERS - CHICAGO FAUCET - #7, HAMMOND - #2002 16.7. WATER HEATER SHALL BE AS SCHEDULED ON DRAWINGS PLUMBING FIXTURES SHALL BE AS SCHEDULED ON DRAWINGS. 17. EXECUTION: 17.1. PIPING INSTALLATION: • EXCEPT AS OTHERWISE INDICATED PROVIDE FACTORY -FABRICATED HANGER AND SUPPORTS COMPLYING WITH MSS SP-58 . HANGERS AND SUPPORTS SELECTED BY THE INSTALLER TO SUIT FIELD CONDITIONS, IN ACCORDANCE WITH MSS SP-69 AND TO MANUFACTURERS' PUBLISHED PRODUCT INFORMATION. USE ONLY ONE TYPE, BY ONE MANUFACTURER FOR EACH SERVICE. SELECT SIZE OF HANGER AND SUPPORTS TO EXACTLY FIT AROUND PIPING WITH INSULATION WITH SADDLE OR SHIELD FOR INSULATED PIPE OR DUCT. PROVIDE COPPER -PLATED HANGERS AND SUPPORTS FOR COPPER -PIPING SYSTEMS. • PIPE TO BE SUPPORTED SECURELY FROM HANGERS AS FOLLOWS: • PIPE HANGERS TO BE SUPPORTED FROM STRUCTURAL STEEL BEAMS BY MEANS OF BEAM CLAMPS. ■ HANGERS ARE NOT TO BE SUPPORTED FROM STEEL FLOOR AND/OR ROOF DECKING. • WHERE REQUIRED, AND UPON LANDLORD'S APPROVAL, CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION OF AUXILIARY STEEL SUPPORT OF HANGER. 17.1.1. DRAIN, WASTE AND VENT: • CAST IRON PIPE MUST HAVE HANGERS THAT ARE 10 FEET ON CENTER MAXIMUM, WITH A MINIMUM OF ONE HANGER FOR EACH SECTION OF PIPE, AND AT CHANGES IN DIRECTION. ■ PVC PIPE SHALL BE SUPPORTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. • THE BASE OF STACK SHALL BE SUPPORTED AT EACH FLOOR AND AT THE ROOF, IF APPROPRIATE. • ALL HORIZONTAL DRAINAGE AND VENT PIPING SHALL BE RUN AT A MINIMUM OF 1/8" PER LINEAR FOOT. • CHANGES IN DIRECTION OR SIZE OF DRAINAGE PIPING SHALL BE MADE WITH APPROPRIATE FITTINGS HAVING LONG RADIUS. • SLIP JOINT FITTINGS WILL BE PERMITTED ONLY ON TRAP CONNECTIONS. 17.1.2. DOMESTIC WATER PIPING: • HORIZONTAL PIPING SHALL BE SUPPORTED FROM STRUCTURE ABOVE AS REQUIRED BY LOCAL PLUMBING CODE, OR AT A MINIMUM AS FOLLOWS: . 1/2" COPPER TUBE- 5'0" • 3/4" & 1" COPPER TUBE -6'0" • WATER LINES SHALL RUN PARALLEL OR PERPENDICULAR TO THE LINES OF THE BUILDING. • PROVIDE FITTINGS AT EACH CHANGE IN DIRECTION OR CHANGE PIPE SIZE. • PROPER ALLOWANCE SHALL BE MADE FOR EXPANSION, AND ALL BRANCHES SHALL BE BLOCKED AS MAYBE NECESSARY TO PREVENT NOISE OR VIBRATION. ',PROVIDE SHUT OFF VALVE AT CONNECTION TO EACH FIXTURE. 17.2. FLOOR DRAINS, INSTALLED ABOVE GRADE, SHALL BE FLASHED WITH 6 LB. SHEET LEAD (AS DIRECTED BY THE LANDLORD) CLAMPED UNDER FLASHING RING, EXTENDING 18" FROM DRAIN IN ALL DIRECTIONS. ■ ALL DRAINS SHALL BE PROVIDED WITH DEEP SEAL TRAP. 17.3. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED TO PERFORM HIS WORK. STATED CUTTING AND PATCHING SHALL CONFORM TO RELEVANT GENERAL CONDITIONS SPECIFICATIONS. 17.4. ALL FLOOR PENETRATIONS SHALL BE CORE DRILLED, PER LANDLORD'S REQUIREMENTS. ALL FLOOR PENETRATIONS SHALL BE PROVIDED WITH WATERPROOF SLEEVE. • PROVIDE CAST BRASS ESCUTCHEON WITH SET SCREWS, DEEP TYPE, TO COVER SLEEVES OR FITTING PROJECTIONS AT FLOOR PENETRATIONS. PROVIDE ESCUTCHEON AT ALL EXPOSED PIPES AT FLOOR, CEILING OR WALL PENETRATIONS. • LOCATION OF ALL OPENINGS THROUGH FLOOR SLABS AND ROUTING OF PIPING TO BE INSTALLED ABOVE THE CEILING OF THE SPACE BELOW THE LEASED PREMISES IS SUBJECT TO THE APPROVAL OF THE LANDLORD. • FURTHER, IF REQUIRED, THIS CONTRACTOR SHALL BE RESPONSIBLE FOR EXCAVATION AND BACKFILL OF TRENCHES AND ANY CONCRETE SLAB REPLACEMENT BEYOND THE NORMAL TOILET ROOM BLOCK -OUT PROVIDED BY THE LANDLORD. • THIS CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE SPECIFIC REQUIREMENTS OF THE LANDLORD. 17.5. ROOF PENETRATIONS FOR VENT SHALL BE CUT AND FLASHED IN STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE LANDLORD'S SPECIFIC REQUIREMENTS. • FLASH VENT PIPES PASSING THROUGH ROOF WITH LEAD ROOF FLASHING CONSTRUCTED OF NUMBER 4 SHEET LEAD, WITH BASE EXTENDING NO LESS THAN 12 INCHES ON EACH SIDE OF VENT. THE VERTICAL PORTION OF FLASHING SHALL EXTEND UPWARD THE ENTIRE LENGTH OF THE P:PE AND BE TURNED DOWN INSIDE THE PIPE. • MINIMUM VENT THRU THE ROOF SHALL BE 3". • THIS CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LANDLORD AND/OR THE LOCAL UTILITY FOR INSTALLATION OF REQUIRED WATER METER. THIS INCLUDES PURCHASE OF REQUIRED METER, AND INSTALLATION OF SAME IN LOCATION DESIGNATED BY THE LANDLORD. • THIS CONTRACTOR SHALL EXTEND DOMESTIC WATER LINE FROM METER LOCATION TO THE LEASED PREMISES. ROUTING OF WATER LINE THROUGH THE MALL COMMON AREAS IS SUBJECT TO THE APPROVAL OF THE LANDLORD. 17.6. THIS CONTRACTOR SHALL PAY ALL FEES REQUIRED FOR INSTALLATION OF WATER SERVICE AND METER. 18. CONTRACTOR SHALL TEST ALL SYSTEMS INSTALLED. 18.1. DOMESTIC WATER PIPING SHALL BE TESTED AT 100 PSI. PRESSURE SHALL BE MAINTAINED FOR A PERIOD OF ONE HOUR. IF LEAKS APPEAR LINES SHALL BE DRAINED AND REPAIRED AND RETESTED. 18.2. SOIL, WASTE AND VENT PIPING SHALL BE TESTED WITH WATER. THE WATER SHALL MAINTAIN A CONSTANT LEVEL AT THE HIGHEST POINT OR AT LEAST TEN FEET ABOVE THE MEAN ELEVATION OF THE PIPING UNDER TEST FOR AT LEAST 4 HOURS. IF LEAKS APPEAR, LINES SHALL BE DRAINED, LEAKS REPAIRED AND RETESTED. 19. DOMESTIC WATER SYSTEMS SHALL BE CHLORINATED IN ACCORDANCE WITH PROCEDURES DESCRIBED IN ALL WH C601-08. CHLORINE SHALL BE ADDED TO THE SYSTEM AT A RATE SUFFICIENT TO PRODUCE A CHLORINE CONCENTRATION OF 50 MG/L AVAILABLE CHLORINE AND HELD IN TRECEi Y ED SYSTEM FOR A 24 HOUR RETENTION PERIOD. AFTER CHLORINATMY WETUKWILA SYSTEM SHALL BE FLUSHED AND PUT INTO SERVICE. JUN DI 2015 20. MATERIALS, EQUIPMENT, AND INSTALLATION SHALL BE GUARANTEVEF ft'ENTEF. PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR FROM THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. • FOR THE SAME PERIOD, THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND//R INSTALLED BY HIM. J J CC H Z U J �Q O w CD CO HD Project No: K 15-2 124.0 13 ■■■■■■■■■■■■■■ �s1,�Tsa■■.■ ■: rill II I :i 5■■EMI 30 :I■ ill ARCHITEC` ■■■ ■■■■■■■■■■■ MIALLIIIPLUMNIILICAD ■■■■■■■■■■■■■■ ■■■■■■■■■■■i■■ 2pi. 00 Z WI CO Z fn Q Z 2 W g Co � • Pr) Qf W L °° mr, co CO = • mom. � L o3v -CP r.0 U • m L C) .E o • 0 v 0 L() Lc \ID L. LL Review Set Issued: 05/06/20 15 Permit Set Issued: 05/26/20 15 Bid Set Issued: 05/26/20 15 Construction Set Issued: Revisions No.: Date: drawn by: MJS reviewed by: M DD/RLL scale: AS NOTED Sheet Title MECHANICAL SPECIFICATIONS Sheet No. M2