Loading...
HomeMy WebLinkAboutPermit M15-0078 - 76 CONVENIENCE STORE - WALK-IN COOLER UNIT76 CONVENIENCE STORE 15060 TUKWILA INT'L BLUR EXPIRED 01/12/16 M15-.0078 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0041000680 Permit Number: 15060 TUKWILA INTERNATIONAL BLVD 76 CONVENIENCE STORE Issue Date: Permit Expires On: M15-0078 7/16/2015 1/12/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: DESMOIRE FRANK SR 5245 BALL CT FAMILY TRUST, CHINO, WA, 97100 KEITH TA 5930 1ST AVE S , SEATTLE, WA, 98108 GREAT SUN CORP Address: 5930 1ST AVE S , SEATTLE, WA, 98108-3248 License No: GREATSC951D1 Lender: Name: Address: /1/ Phone: (206) 683-1414 Phone: (206) 329-8027 Expiration Date: 3/27/2017 DESCRIPTION OF WORK: INSTALL ONE (1) WALK-IN COOLER UNIT Valuation of Work: $12,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $350.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: 1 1/(41 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: R4LF\:R $!RK This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 18: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshal's Office and are acceptable with the following concerns: 14: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. (INSTALL A LISTED, WEATHERPROOF, RATE COMPENSATION TYPE HEAT DETECTOR IN THE COOLER.) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 15: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKW. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M l ' o S Project No. ( Date Application Accepted: _ , 1" 1 J Date Application Expires: % J 11 J I C (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 566 0 IV,K wt � 1-61 f - &V rrl Tenant Name: —7/7 COM tre e5f0l� PROPERTY OWNER Name: E g 5 F z-Z Address: /r7 06 0 %t1�vf/i(ti . .i/t4.(/ • 7� ,,/ S wo( City: f, /G State: tA/2 Zip: cg(e)F' CONTACT :PERSON — person receiving all project communication Name: j/ 4, / �/ �'t�U-e S . Address: _q 3v /� State: Ltm Zip: City: ftt 11 v7x Phone: J.:0/_ _ 653.1 7v Fax: jot_ . G%__ 7C�� (7 Email: . at /-e.,J514 G0✓�• C-011i1 King Co Assessor's Tax No.: (X) y/ o) — 06 g" 0 Suite Number: Floor: New Tenant: ❑ Yes j'. No MECHANICAL CONTRACTOR INFORMATION Company Name: `✓ea1-wm Address:5 4 t. 5 City: �_" ` ._ State: � ,7F/DEr Phone: a0/ _ 3� % 50)7 Fax: »f , q ,vc Contr Reg No.:6_ F 7 p9 xp Date: 3 4Tukwila Business License No.: Valuation of project (contractor's bid price): $ j.1./ 00 Describe the scope of work in detail: Y., `j/,{/tic 0 j,{/pt (4 — Z vter?'" %y / f Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric 4 Gas ❑ Other: H1ApplicationsTorms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment ' Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWOR AUTHORIZED AGENT: Signature: . Print Name: (7\ ( Mailing Address: 30 1 %4-c. Day Telephone: City Date: Of7/4c- -65 3-/fR:/ f WO State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: Augusl 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY I PAID $283.03 M15-0078 Address: 15060 TUKWILA INTERNATIONAL BLVD Apn: 0041000680 $283.03 MECHANICAL $269.55 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5746 R000.322.900.04.00 0.00 $13.48 $283.03 Date Paid: Thursday, July 16, 2015 Paid By: BIRK ENVIRONMENT Pay Method: CHECK 1328 Printed: Thursday, July 16, 2015 4:20 PM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY I PAID PermitTRAK $67.39 M15-0078 Address: 15060 TUKWILA INTERNATIONAL BLVD Apn: 0041000680 $67.39 MECHANICAL $67.39 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R5580 R000.322.102.00.00 0.00 $67.39 $67.39 Date Paid: Friday, June 19, 2015 Paid By: GREAT SUN CORP Pay Method: CHECK 8642 Printed: Friday, June 19, 2015 3:18 PM 1 of 1 CIR-ifr-VrSYSTEMS �I 1 Ib r F opt rn pi z i o '' AI 50106.1 A4 FT a o 11 831N3311W83d 1 (S2f3H1c 1 MEC i WALK-IN COOLER CONFIGURATION 53/2" 1'-53/4' "7'-11" 1'-83/4" 40'-9" 8'-7" co QO 6, FO Ci Go 0 ,rn PROJECT:' --- ?=;�' } / 76 Convenience Store n -r,. rn Z N r1 / 15060 Tukwila Int. Blvd , _ 0 3' rn r D / Tukwila, WA 0 rn w — = o o - Ei 6 co co x cwowN 0 (o X A7c m (0 m w�C) O — T X 0) - - • Q _ Qo N m III r ,• o c 77 • II CO 17 w w cn m mm cp cpo CO -o = m CO CO o -vm0 w x w m x- m r. m p o co * v n' v 0m o 6 m v m w 0 coco a co '0 w w 7k- CD m o o w m• ID cn = \ — Iv* .-i- 0 5 * o0 v o = o - i 11 D o w 3 i -0 ZD 7 co c m o- o D m m Refrigeration Component CD = `� %, - c r- Cr �, 0 0 0,rrr 0 'D,m, = 1y 0 Fri C i'P1 •n vzo 0 m Condensing Unit T Y OF TUKWIL Oty. Model # SUN 1 9 2015 Unit Cooler Oty. Model # PERMIT CENTER System Capcity BTU/H Exterior light switch w/ plot light Vapor proof light fixture Thermometer flush mounted Ri:C; ivr.n Wall Interior: 25 GA Stucco embossed galv. aluminum Wall Exterior: 25 GA Stucco embossed galv. steel Ceiling Interior: 25 GA stucco embossed galv. allum. Ceiling Exterior: 25 GA stucco embossed galv. steel 4" Hardnose T&G high density urethane foam rail (Non CFC class I rigid foam w/ R-25 Insulation) & 25 GA galvanized steel skins, meeting ASTM A525, 4 inch wood frame. The panels shall comply with flame spread & smoke index development OR ASTM E85. The Panels are joined together utilizing Kason type 1156 B Camlock Rigid rail i locking point. uoll.ena0 4UOJd aanjx!d ion 01 uop!MS 41.16!l Spring Hindged for Automatic Door Closure 831N33 1IINa3c 5 co 0 _C 0 73 n '—n mm r- v c ©r 0- o xipm mC 0C 0 C M ' c 3 C •;.; . oNJ i'i1 r �0 0 z0 cr DZ m ainpu 346l1Mid iodeA 0 Trap & Terminate above floor sink per local codes rr caulking 3/8"x6" Round head bolt /8 3 „ USS flat washer } Air flow Evap. Drain pan 3/$" flat washer 3/8" Nut Drain line & Evap. Detail (Typical) Exit at nearest point Copper tubing Min. Pitch 1/4' — Per foot wrap inside portion wit-heaterafitfxeezer. C p t vm , cmmc _Com ) o m -I ,-. E. ® m 7 o rn�� to=' ; ,Da m n /7x7.0_,. v�xiav ( iI v m `° C Z iv A m : <C 33 r D rn v v V v vvv v1vv1 vvvv v1 v. vv. d oovo dv4 v v v vv v v 4v v v v v 4 0 z0 cr)z -n- �o v� v 0 tri 0mCr:a n. �t Eri ms' CI) 00 {. i so • O\co = C cuoi m m o =I Z y m = .m 0 t.-- o t7) (I) rn co IVA IS) 0 3.3 • _ in- -0 o ?Pc City of Tukwila Department of Community Development 12/1/2015 KEITH TA 5930 1ST AVE S SEATTLE, WA 98108 RE: Permit No. M15-0078 76 CONVENIENCE STORE 15060 TUKWILA INT'L BLVD Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/12/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. Hit is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/12/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: M15-0078 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0078 DATE: 06/22/15 PROJECT NAME: 76 CONVENIENCE STORE SITE ADDRESS: 15060 TUKWILA INT'L BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AA{��AA tt``II A Building ivisiori ...i Fire Prevention Public Works Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/23/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 07/21/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 GREAT SUN CORP Page 1 of 2 Home Inicio en Espanol Contact. Search'L&I A-Z Index Help My Secure I: &I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries GREAT SUN CORP Owner or tradesperson Principals TA, KEVIN, PRESIDENT Doing business as GREAT SUN CORP WA UBI No. 601 984 317 5930 1st Ave S SEATTLE, WA98108 206-329-8027 KING County Business type Corporation Governing persons CHAU TAN KEVIN TA; MIKE AU YONG; YEN LEE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties INST EQUIP/STAT FURN/LAB T/LO License no. GREATSC951DI Effective — expiration 03/21 /2005— 03/27/2017 Bond ._...._....... Philadelphia Indemnity Ins Co Bond account no. PB03138600212 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 02/09/2012 03/10/2012 Expiration date Until Canceled Bond history Insurance ........................ Farmers Ins Exchange $1,000,000.00 Policy no. 035029268 Received by L&I Effective date 02/17/2015 02/15/2015 Expiration date 02/15/2016 Insurance history Savings .................... No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601984317&LIC=GREATSC951D1&SAW= 7/16/2015