Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0080 - SOUND TRANSIT - AIR CONDITIONING UNIT
SOUND TRANSIT 4524 S 134 PL M15-0080 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2613200007 Permit Number: 4524 S 134TH PL Issue Date: Permit Expires On: SOUND TRANSIT M15-0080 12/28/2015 6/25/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CPSRTA (SOUND TRANSIT) 401 S JACKSON ST , SEATTLE, WA, 98104 NICOLE SIEBEL 401 S JACKSON ST , SEATTLE, WA, 98104 AFFIDAVIT ON FILE Phone: (206) 370-5693 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALLATION OF AIR CONDITIONING UNIT AT EXISTING TRACTION POWERED BY CENTRAL LINK LIGHT RAIL SUBSTATION Valuation of Work: $11,170.00 Type of Work: Fuel type: Fees Collected: $350.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: pf4e, Date: I2 17,0M I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: AlciL sood Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL i CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.Kiv Mechanical Permit No. tt y 1 'CCe)0 Project No. Date Application Accepted: Date Application Expires: 0 ' 1� (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 4514 I e + 7 (ing Co Assessor's Tax No.: 004300300 Site Address: Suite Number: Floor: Tenant Name: CPSRTA (Sound Transit) PROPERTY OWNER Name: CPSRTA Address: 401 S Jackson Street City: Seattle State: WA Zip: 98104 CONTACT PERSON — person receiving all project communication Name: Nicole Siebel Address: 401 S Jackson Street City: Seattle State: WA Zip: 98104 Phone: (206) 370-5693 Fax: Email: nicole.siebel@soundtransit.org New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Installation of air condition unit at existing traction powered Central Link Light Rail substation. 11,170 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement m Fuel Type: Electric 1 Gas ❑ Other: H:Wpplications\Forms-Applications On Line\2011 Applications \Mechanical Permit Application Revised 8.9-I1.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor fumace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty I Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Q` Signature: I TH RIZED AGENT: Print Name: Nicole Siebel for CPSRTA Mailing Address: 401 S Jackson Street Date: (PAr3/‘ Day Telephone: (206) 370-5693 Seattle WA 98104 City State Zip H:\Applications\Forms-Applications On Line\201 I Applications \Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 201 I bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK . $1,3O 80 EL15-0589 Address: 11060 TUKWILA INTERNATIONAL BLVD BLDG Apn: 0323049029 $303.98 ELECTRICAL $289.50 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $289.50 TECHNOLOGY FEE $14.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.48 EL15-0590 Address: 4524 S 134TH PL Apn: 2613200007 $303.98 ELECTRICAL $289.50 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $289.50 TECHNOLOGY FEE $14.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.48 M15-0080 Address: 4524 S 134TH PL Apn: 2613200007 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $13.48 M15-0081 Address: 11060 TUKWILA INTERNATIONAL BLVD BLDG Apn: 0323049029 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5633 R000.322.900.04.00 0.00 $13.48 $1,308.80 Date Paid: Monday, June 29, 2015 Paid By: CPSRTA (SOUND TRANSIT) Pay Method: CREDIT CARD 087034 Printed: Monday, June 29, 2015 11:17 AM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit rill W PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project; G(6At)b. 'T "-Aic rr Type of Inspection: 41604/1--AnGAL cAr�tL Address: Date Called: Special Instructions: CALL Date Wanted % ' i . a.rr p.m. Requester. PAUL Phone No: 360 3c 1- s-c9 o Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: r Dater /06 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. rocr=© Non -Critical Instrument House HVAC Installation Cutsheets RECEIVED CITY OF Tit4WILA JUN 2 9 2015 PERMIT CENTER Page 3 of 11 Motor BHP I) Octave Center freq. 63 1.48 II 1.06 (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 1.22 0.79 (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 78 1 84 77 II 84 75 83 77 84 125 76 78 75 77 73 76 73 76 250 68 69 68 69 65 67 67 68 500 1000 63 63 64 64 60 61 62 63 58 58 1 60 60 54 55 59 59 2000 54 54 54 54 50 51 53 53 4000 53 53 51 51 49 49 49 50 8000 47 47 44 45 42 44 42 44 (a) Blower Operation = supply fan only sound power, dB re 10-12 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10'12W. (c) Test duct dimension: 14 inches wide by 24 inches high by 6 feet long (0.36 m X 0.61 m X 1.83 m) for side ducted inlet; Tes duct termination is flush with the wall in the reverberation room; No test duct elbow ( 3uct end (sound reflection) correction: (9,5,2,1,0,0,0,0) dB for side ducted inlet at (63,125,250,500,1k,2k,4k,8k) Hz Base unit 4 & 5 ton Precedent direct or belt drive with Horizontal Configuration Sound component Ducted Discharge Power source 60Hz. Motor tap (high/low) ITgh Low Supply fan speed (rpm) 1061 1124 920 1076 Supply fan S.P. (in H20) 0.55 1.18 0.42 1.17 Supply fan CFM 1728 1024 1475 890 Motor BHP 1.5 1.06 1.22 0.79 Octave Center freq. (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 63 87 92 87 92 83 92 85 92 125 81 82 79 81 77 79 78 79 250 75 76 72 73 72 73 71 72 500 73 73 69 70 69 69 68 68 1000 69 69 66 66 65 66 65 65 2000 65 66 62 63 61 62 61 62 4000 63 63 59 60 59 60 57 59 8000 56 57 52 53 51 53 50 52 (a) Blower Operation = supply fan only sound power, dB re 10-12 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10-12 W, (c) Test duct dimension: 15.5 inches wide by 18 inches high by 6 feet long (0.39 m X 0.46 m X 1.83 m) for side ducted discharge Test duct termination is flush with the wall in the reverberation room; No test duct elbow (d) Duct end (sound reflection) correction: (10,6,2,1,0,0,0,0) dB for side ducted discharge at (63,125,250,500,1 k,2k, 4k,8k) Hz Base unit Sound component Power source 1 4 & 5 ton Precedent direct or belt drive with Downflow Configuration Ducted Discharge 60Hz. II 11 1 http://tranenetclkl/common/clkpsodocs/PrecedentSoundData.htm 3/14/2006 System Lineup PRODUCT MODELS AND CONTROLLERS Au - ACV - 2 Indoor Unit Models Mitsubishi Electric indoor units are available in a wide variety of styles and capacity ranges to provide an almost unlimited number of applications. If there is a problem, we have a solution. PKA (HA/HAL, KA/KAL) WALL —MOUNTED SERIES Air -Conditioner and Heat Pumps 12,000 to 34,200 Btu/h • PKA-HAL/KAL use a wireless hand-held controller • Ideal utilization in the following spaces: Churches, classrooms, day care centers, out buildings, guard houses, and more PCA CEILING —SUSPENDED SERIES Air -Conditioner and Heat Pumps 24,000 to 42,000 Btu/h • i-see" Sensor optional • Knockout for ventilation air • AUTO fan speed control • Ideal for applications such as: Restaurants, classrooms, building entrances, retails stores, quick additions and renovations l fic PLA CEILING —RECESSED SERIES Air -Conditioner and Heat Pumps 12,000 to 42,000 Btu/h • Built-in condensate lift mechanism • i-see" sensor optional • Knockouts for ventilation air and branch duct run • Ideal utilization in the following spaces: Retail stores, classrooms, office spaces, conference rooms, lobbies, and more PEA/PEAD HORIZONTAL DUCTED SERIa= E Air -Conditioner and Heat Pumps 12,000 to 42,000 Btu/h OGgI.`" 1.41 • • Automatic fan speed control • Built-in condensate lift mechanism • Ideal utilization in the following spaces: Retail stores, classrooms, office spaces, conference rooms, lobbies, and more 30 .•.MITSUBISHI ELECTRIC Outdoor Unit Models The Mitsubishi Electric P-Series outdoor units, either cooling -only (PUY) or heat pump (PUZ) models, are compatible with each of the four different style indoor units, creating a wide range of installation possibilities. The outdoor units are completely assembled, piped, wired, and test run at the factory. The rugged, heavy-duty cabinet is constructed from a galvanized steel plate, finished with an electrostatically applied, thermally -fused acrylic or polyester powder coating for corrosion protection. The front fan grille is high -impact ABS plastic. The Mitsubishi Electric built INVERTER -driven compressors for models PUY/Z- A18/24/30/36 are DC twin -rotor type, and the compressor for model PUY/Z- A42 is a Frame Compliant Scroll compressor. All compressors are part of the Variable Speed Inverter Drive Technology, which varies the compressor speed dynamically to match the room load, increasing the efficiency of the system and resulting in significant energy savings. Electronic linear expansion valves are used to measure precisely and provide fine controls to the refrigerant flow ensuring exact capacity delivery. The outdoor units employ advanced Pulse Amplitude Modulation (PAM) circuitry. PAM adjusts the form of the current output wave to emulate the form of the supply voltage wave to effectively utilize 98% of the input power supplied. ,kcc-I PUY/PUZ-NHA3 Cooling -only and Heat Pump • 4-7 12,000 to 18,000 Btu/h Acc-2 24,000 to 36,000 Btu/h a Q r PUZ-HA**NHA2 (H2i • i 5 Hyper -Heating INVERTER rl 4 r 42,000 Btu/h 30,000 to 36,000 Btu/h (See page 44 for more information) Set Temperature Timer Menu Mode Set Time Timer On/Off WIRED REMOTE CONTROLLER On/Off Fan Speed Filter Test Run Check IAirflow Up/Down r Louver .. r..M,.., rC+l:..>re. �r„CE erCss Tl �i 1rINr•n>y,r �: W m "AlrrtYsryr>asow uor to lien ee.Yti:lll'>eYs nr, V�"" ..1 (MX. COr:HM. �1;., • od44u1Mrt 10 Wired controller for the indoor unit. (multi-lingual) Ventilation ..MITSUBISHI ELECTRIC 31 IPFiA.rJCKA MODELSIU'v4 I F ER R PKA COOLING -ONLY k 1 _`fo q r ^ ' HA/KA = Wired controller HAUKAL = Wireless controller BS = Seacoast Protection V ( _ .,..... 144IFJiA l i1'[p;�rrf r 1��,o,'� fu(g,rra:11.4111 1Z+ 31Ss19: fR,Aci,4.:ity, �,Y�� r tiVal• /I rr t �ll� J�,�ill rah it '1nfnl- Srl„� •:1i,`,4,.F1JR '!M 1'.% n r s�Zlll t :+ ctk a TtJtf li,,.) 9�I,L I �: r '' k*t i Rated Capacity Btu/h 12,000 18,000 24,000 30,000 34,200 I Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-34,200 '1 Total lnput W 1,190 2,240 2,270 4,130 5,030 Cooling Energy Efficiency SEER 15.2 15.3 17.0 _ 15.5 14.0 Moisture Removal Pintsm 2.0 5.2 5.0 8.1 9.2 Sensible Heat Factor 0.81 0.68 0.77 0.70 0.70 Power Supply Phase, Cycle, Voltage 1-phase, 60Hz, 208 / 230V '2 Indoor - Outdoor St - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24 Voltage Indoor - Remote Controller DC12V: Wired Type (HA/KA) Indoor - Remote Controller Wireless Type (HAUKAL) MCA A 1 Fan Motor F.L.A. 0.33 0.36 0.57 Fan Motor Output W 30 56 56 DRY (CFM) 320-370-425 635-705-775 705-810-920 Airflow (to -Mid -Hi) WET (CFM) 290-335-380 570-635-700 635-730-830 Sound Pressure Level (Lo-Mid-Hi) dB(A) 36-40-43 39-42-45 43-46-49 Indoor Unit External Finish Color Munseli No. 1.OY 9.2 / 0.2 W: In. 35-3/8 46-1/16 1 Dimension Unit 0: In. 9-13/16 11-5/8 H: In. 11-5/8 14-3/8 Weight Unit Lbs. 29 46 Field Drainpipe Size I.O. In. 5/8 MCA A 13 18 25 MOCP A 15 1 20 30 40 Fan Motor F.L.A. 0.35 0.75 Fan Motor Output W 40 75 Model (Type) DC INVERTER -driven Twin Rotary Compressor R.L.A. 12 L.RA. 14 ( 17.5 0utdoorUnil Airflow CFM 1,200 I 1,940 Refrigerant Control Linear Expansion Valve Sound Pressure Level at Cooling '1 d8(A) 46 1 48 External Finish Color Munsell No. 3Y 7.8 / 1.1 Wain. 31-1/2 37-3/8 •Dimensions 0: In. 13 + 7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 Weight Lbs. 90 1 97 163 . Remote Controller Type HA/KA: Wired Controller; HALA(AL: Wireless Controller (Packaged with Indoor Unit) Type R410A Charge Lbs. 2,14 1 3,12 6,10 Refrigerant 00 Type (fl oz.) MEL56 {20) FV50S (28) Gas Side 0.D. In. 1/2 5/8 ' Refrigerant Pipe Liquid Side 0.D. In. 1/4 3/8 Height Difference (Max.) Ft. 100 Refrigerant Pipe Length Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. '1. Rating conditions (coating) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). Indoor units receive power from outdoor units through field -supplied interconnected wiring. 4pecifications are subject to change without notice. LIMITED WARRANTY 1 Seven-year warranty on compressor. Five-year warranty on parts. 34 AMITSUBISHIELECTRIC Job Information 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Sound Transit Track Power Substation Seattle Main Office (Y31)Michael Woods Tag Quantity Unit Information AC-5T 1 Model number THC060 Tonnage 5 Ton Min. Unit Operating Weight 679.0 lb Design Airflow 2000 cfm Unit function DX cooling Max Unit Operating Weight 900.0 lb Cooling Information Gross Total Capacity 65.86 MBh Gross Sensible Capacity 65.88 MBh Gross Latent Capacity 0.00 MBh Net Total Capacity 63.39 MBh Net Sensible Capacity 63.39 MBh Net Sensible Heat Ratio 1.00 Number Cooling Entering Dry Bulb 90.00 F Cooling Entering Wet Bulb 53.00 F Cooling Leaving Unit DB 61.08 F Cooling Leaving Unit WB 39.33 F Ambient Temp 85.00 F Heating Information Heating capacity Without electric heat Motor/Hectricat Information Voltage 208-230/60/1 Design ESP 0.700 in H2O Indoor Motor Power 0.60 kW Indoor Mtr. Operating Power 0.81 bhp Compressor Power 3.20 kW System Power 4.17 kW MCA 41.40 A MOP 60.00 A Condenser Fan FLA 2.50 A Evaprator Fan FLA 7.60 A Compressor 1 RLA 25.00 A Electrical values provided ere estimated only and are subject to change without notice and may differ from nameplate values. Field installed low or high static drive kits may be needed. Please check the fan performance tables in the product catalog for application ranges. 6/17/2013 Product Version 1.0.0.0 Page 1 of 2 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Job Information THANE" Sound Transit Track Power Substation Seattle Main Office (Y31)Michael Woods Tag Quantity AC-5T 1 Model number THC060 nformation for LEED Projects ASHRAE 90.1 Yes IEER Rating 0.00 Refrig charge (HFC-410A) - ckt 1 6.1 lb Compressor Power 3.20 kW Refrig charge (HFC-410A) - ckt 2 0.0 Ib Outdoor Motor Power 0.37 kW Rated capacity (AHRI) 61.00 MBh Indoor Mtr. Operating Power 0.81 bhp EER @ AHRI Conditions 14.8 EER Exhaust fan power 0.65 kW Note: This product meets the minimum equipment efficiency requirements of ASHRAE Standard 90.1.2007 end -2010 (which ere based on AHRI standard rating conditions) and, therefore. also meets the LEED "Minimum Energy Performance' prerequisite in the Energy and Atmosphere section. The power data listed above is at actual user -entered conditions. Refer to the product catalog for performance at AHRI standard rating conditions. The LEED Green Building Rating System", developed by the U.S. Green Building Council, provides independent, third -party verification aol a building prn3nct meets gran building end performance measure, Electrical values provided are estimated only and are subject to change without notice and may differ from nameplate values. Field Installed low or high static drive kits may be needed. Please check the fan performance tables in the product catalog for application ranges. 81172013 Product Version 1.0.0.0 Page 2 of 2 TRANE° Sound Transit Track Power Substation EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE 4 1/4" 27 5/8" 47 7/8" 2" ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) THROUGH THE BASE CONDENSATE PLAN VIEW UNIT DIMENSION DRAWING SUPPLY 237/8" 1 a RETURN .— / 00 32 1/4" 4 3/4" —19 1/4" —88 518" CONDENSATE 9 3/8" " 18 3/4'—' TOP PANEL 111 DIA. HOLE ■• SERVICE NIT CONTROL WIRE GAUGE PORT ACCESS 318" DIA. HOLE UNIT POWER WIRE 3.1 D Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job') 6/17/2013 10:48:04 AM CONDENSER FAN CONDENSER COIL ONTROL AND COMPRESSOR ACCESS PANEL NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. 40 7/8" -'--3 7/8" PACKAGED COOLING 18 1/2 9 5/8" 5 5/8" DIMENSION DRAWING 4 1/4" 5 5/8" 7 518" 531 /4 HORIZONTAL AIR FLOW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 1 TRAM Sound Transit Track Power Substation 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job) 6/17/2013 10:48:04 AM 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" ISOMETRIC -PACKAGED COOLING 4 3/4" TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE, Page: 2 Sound Transit Track Power Substation 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job') 6/17/2013 10:48:05 AM 'ELECTRICAL / GENERAL DATA GENERAL (2)(4)(6) Model: THCO6OF Unit Operating Voltage: 187-253F Unit Primary Voltage: 206 Unit Secondary Vottage 230 Unit Hertz: 60 Unit Phase: 1 SEER '15.0 Standard Motor Oversized Motor Minimum Circuit Ampacity. "41.4 Minimum Circuit Ampaclty. N/A Maximum Fuse Size: 60.0 Maximum Fuse Size: N/A Maximum (HACR) Circuit Breaker. 60.0 Maximum (HACR) Circuit Breaker. N/A Field Installed Oversized Motor Minimum Circuit Ampacity. N/A Maximum Fuse Size: N/A Maximum (HACR) Circuit Breaker. NIA INDOOR MOTOR Standard Motor Outsized Motor Field Installed Oversized Motor Number .1 Number: N/A Number: N/A Horsepower. 1.0 Horsepower. N/A Horsepower: N/A Motor Speed (RPM): — Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase: 1 Phase: N/A Phase: N/A Full Load Amps: 7.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: — Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: .1 Number. 1 Horsepower: 4.4 Horsepower. 0.40 Phase: 1 Motor Speed (RPM): 1075 Rated Load Amps: 25.0 Phase: 1 Locked Rotor Amps: 134.0 Full Load Amps: 2.5 Locked Rotor Amps: 6.6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type 'R-410 Phase: N/A Type: Throwaway Horsepower. N/A Furnished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Circuit #1 6.1 lb Full Load Amps: N/A Recommended 16"x25"x2" Circuit #2 N/A Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not Include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 3 Sound Transit Track Power Substation TIRAuvE. 3-10 Ton R410A PKGO Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job') 6/17/2013 10:48:05 AM 1 CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST HEATER REHEAT THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD 20.0 Ib SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET O 219.0 Ib O 135.0Ib (E) LENGHT (F) WIDTH 774.0 Ib 679.0 Ib O O 189.0 Ib 137.0 Ib 43" 21" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LES TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS. RIGGING AND CENTER OF GRAVITY TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 4 Sound Transit Track Power Substation 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job) 6/17/2013 10:48:05 AM CLEARANCE 36" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" PACKAGED COOLING CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 48" CLEARANCE 36" CLEARANCE ROOF OPENING --- UNIT OUTLINE--- 46" 88 5/8" PACKAGED COOLING 1 46" 53 1/4" DOWNFLOW TYPICAL ROOF OPENING TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 5 reavE° Sound Transit Track Power Substation 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not' In Job') 6/17/2013 10:48:05 AM L.1 U •*::::::::::• ..*. : ••• '• \ 00 00 ECONOMIZER HOOD ECONOMIZER HOOD 6 7/8" 16 3/4" ECONOMIZER HOOD ACCESSORY TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 6 Page 3 of 11 Motor BHP 1.48 I 1.06 j 1.22 0.79 Octave Center freq. (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 63 78 84 77 84 75 83 77 84 125 76 78 75 77 73 .76 73 76 250 68 69 68 69 65 67 67 68 500 63 63 64 64 60 61 62 63 1000 58 58 60 60 54 55 59 59 2000 54 54 54 54 50 51 53 53 4000 8000 53 53 51 51 49 49 49 50 47 47 44 45 42 44 42 44 (a) Blower Operation = supply fan only sound power, dB re 10-12 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10 -12W. (c) Test duct dimension: 14 inches wide by 24 inches high by 6 feet long (0.36 m X 0.61 m X 1.83 m) for side ducted inlet; Test duct termination is flush with the wall in the reverberation room; No test duct elbow (d) Duct end (sound reflection) correction: (9,5,2,1,0,0,0,0) dB for side ducted inlet at (63,125,250,500,1k,2k,4k,8k) Hz Base unit 4 & 5 ton Precedent direct or belt drive with Horizontal Configuration Sound component Ducted Discharge Power source 60Hz. Motor tap (high/low) H gh Low Supply fan speed (rpm) 1061 1124 920 1076 Supply fan S.P. (in H20) 0.55 1.18 0.42 1.17 Supply fan CFM 1728 1024 1475 890 Motor BHP 1.5 1.06 1.22 0.79 Octave Center freq. (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 63 87 92 87 92 83 92 85 92 125 81 82 79 81 77 79 78 I 79 250 75 76 72 73 72 73 71 72 500 73 73 69 70 69 69 68 68 1000 69 69 66 66 65 66 65 65 2000 65 66 62 63 61 62 61 62 4000 63 63 59. 60 59 60 57 59 8000 56 57 52 53 51 53 50 52 (a) Blower Operation = supply fan only sound power, dB re 10-12 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10'12 W. (c) Test duct dimension: 15.5 inches wide by 18 inches high by 6 feet long (0.39 m X 0.46 m X 1.83 m) for side ducted discharge Test duct termination is flush with the wall in the reverberation room; No test duct elbow (d) Duct end (sound reflection) correction: (10,6,2,1,0,0,0,0) dB for side ducted discharge at (63,125,250,500,1 k,2k, 4k,8k) Hz Base unit Sound component Power source 4 & 5 ton Precedent direct or belt drive with Downflow Configuration Ducted Discharge 60Hz. II II http://tranenetclkl/common/clkpsodocs/PrecedentSoundData.htm 3/14/2006 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Job Information G. TRANE' Sound Transit Track Power Substation Seattle Main Office (Y31)Michael Woods Tag Model number Quantity AC-4T 1ph 4TCY4048-1000 1 Refrigerant Cooling Capacity Electrical characteristics Unit Information AHRI Capacity Design Airflow Design net total capacity Design net latent capacity Cooling EDB Cooling EWB Design heating capacity Cooling Information R-410A Pkg cooling 14 SEER 4 Ton 14 SEER 208-230/1/60 I 48500.00 Btu/hr 1400 cfm 48706.00 Btu/hr 12529.00 Btu/hr 80.00 F 87.00 F SEER @ AHRI Field applied voltage Design net sensible capacity Cooling LDB Cooling LWB Electric heat capacity @ 0®6 volts Heating LDB Low speed cooling airflow Low speed net total capacity High speed cooling airflow High speed net total capacity Medium speed cooling airflow L. Medium speed net total capacity Heating Information 14.20 btuh/watt 230 Volt 36177.00 Btu/hr 56.00 F 55.00 F 1806 cfm 1583 cfm 49617.00 Btu/hr Low speed cooling TESP Low speed net sensible capacity High speed cooling TESP High speed net sensible capacity Medium speed cooling TESP Medium speed net sensible capacity Low speed heating airflow Low speed heating leaving temperature High speed heating airflow Med / med-low speed heating Airflow Med low spd.heating leaving temperature Med-high speed heating airflow Low speed heating TESP High speed heating leaving temperature High speed heating TESP Med / med-low spd htg TESP Med-high spd heating TESP Med-high speed heating Ivg temperature 4/12/2013 Product Version 1,0 1.164 In H2O 0.895 In H2O 38673.00 Btu/hr Page 1 of 1 Page 1 of 1 13 SEER unit selection Sound Transit Track Power Substation AC-4T 1ph Refrigerant: No option selected Cooling Capacity: No option selected Electrical characteristics: No option selected j 4 SEER unit selection Refrigerant: R-410A Pkg cooling 14 SEER Cooling capacity: 4 Ton 14 SEER Electrical characteristics: 208-230/1/60 AHRI data AHRI Capacity: 48500.00 Btu/hr SEER @ AHRI: 14.20 btuh/watt EER @ AHRI: 12.0 EER field arcked voltage Field applied voltage: 230 Volt Design. maem per9'ntance Design Airflow : 1400 cfm Design net total capacity: 48706.00 Btu/hr Design net sensible capacity: 36177.00 Btu/hr l ooi w per onance Design net latent capacity: 12529.00 Btu/hr Cooling LDB: 56.00 F Cooling LWB: 55.00 F Medium speed cooling airflow: 1583 cfm Medium speed cooling TESP: 0.895 in H2O Medium speed net total capacity : 49617.00 Btu/hr Medium speed net sensible capacity : 38673.00 Btu/hr High speed cooling airflow: 1806 cfm High speed cooling TESP: 1.164 in H2O kdittitional Result 1n: orrnetion Ship Cycle Ship cycle: Standard ship cycle Accessories Roof curbs: Hinged filter access door. Thermostat: Roof curb Hinged filter access door No option selected Crankcase heater: Low ambient control: Crankcase heater Low ambient control kit Exderided Warranties ompressor parts warranty: None Parts only: None file://C:\Documents and Settings\jdella.CDI\Local Settings\Temp\7z0468.tmp\1.5-5 ton Pkgd. Cooling Roof... 8/29/2013 Sound Transit Track Power Substation TRANI' 4/12/2013 8:56:42 AM 175D Cooling (Wet Coil), Horizontal Configuration AC4I' 1ph o 33) 4QD 45) �tirflONRidstate M -M ■ 1 e 1 1 11 1 1 1 1 1 1 1 I 1 I►► r Till ► I► 1 1 Q1 02 Q3 04 Q5 Q6 07 Q8 Tctd tic F ue(in!-�j TOPSS Fan Curve / Acoustical Information Page: 1 Sound Transit Track Power Substation 1.5-5 ton Phgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:40 AM UNIT - TOP VIEW .71" .56' SECTION Y-Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS d .70^ SECTION X-X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 2 5/16" 6 15/16" 33/8" 1711/16" - 1711/16"- j-1215/16'1 UNIT - BACK AND PENETRATION VIEW re- 37 3/8' - 22 9/16" 14 1/8" 24V ENTRY 11 5/16" 8 7/8 4 5/8" UNIT- BOTTOM PENETRATION VIEW NOTES: VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 20 7/8' OWER ENTRY 1 1/8 DIA HOLE 1 3/8' DIA. KNOCKOUT CONDENSATE DRAIN FOR 1 5/8" DIA. KNOCKOUT 3/4" FEMALE NPT 4 3/16" OWER ENTRY 1 1/6" DIA. HOLE 1 3/8" DIA KNOCKOUT 5 7/8" 1 5/8" DIA. KNOCKOUT SINGLE POINT ENTRY 1 3/8" DIA. HOLE 1 5/8" DIA. KNOCKOUT 2 7/16" DIA. KNOCKOUT UNIT - LEFT SIDE VIEW UNIT - RIGHT SIDE VIEW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 1 TRANE Sound Transit Track Power Substation 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:41 AM 'ELECTRICAL / GENERAL DATA POWER CONNECTION Model: 4TCY4048A1 Voltage Range: 208-230/1/60 Min. Circuit Arnpacity: 33.8 Max. Circuit Breaker. 50.0 Prot. Rtg. Recmd: 50.0 EER/SEER 11.9/14.25 Noise Rating # : 72 COMPRESSOR Number. 1 Phase: 1 Rated Load Amps: 20.5 Locked Rotor Amps: 109.0 OUTDOOR MOTOR Number. Horsepower .25 Phase 1 Full Load Amps: 1.40 Locked Rotor Amps: 3.37 INDOOR MOTOR Number: Horsepower. Motor Speed (RPM): Phase Full Load Amps: Locked Rotor Amps: .75 Variable 1 6.8 6.8 REFRIGERANT Type: Factory Charge Circuit #1: 'R-410A 8.2 HEATER Model: Voltage: Phase: Heater Capacity (Kw): Heater (Btu): # of Stages: Stage # 1: Stage # 2: MCA: MBS: SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION Single Power Entiy Kit Minimum Circuit Ampacity Maximum Over -Current Device 1. Single Circuit Power fuses are supplied if required for unit and / or heater. 2. Wiring requirements if unit and electric heaters are operated from a single circuit using a single power entry kit. NOTES: UNIT ONLY 1. Rated in accordance with A.H.R.I. Standard 2101240. 2. Rated In accordance with D.O.E. test procedure. 3. Rated in accordance with A.H.R.I. Standard 270. ELECTRIC HEATER ACCESSORY ONLY 4. Any power supply and circuits must be wired and protected in accordance with local electrical codes. 5. The MCA values listed are for electric heater only. 6. The MCA values listed are for electric heater only. 7. Field wire must be rated at least 75 C. 8. The HACR circuit breaker is for U.SA. installations only. 9. For Canada Installations reference only. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 2 Sound Transit Track Power Substation 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1 ph Qty: 1 Tags: AC-4T 1 ph 4/12/2013 8:56:41 AM W1 W3 W4 CENTER OF GRAVITY UNIT WEIGHT CORNER WEIGHT CENTER OF GRAVITY SHIPPING NET W1 W2 W3 W4 A B 607.01b 479.0 lb '168.0 lb 105.0 lb 79.0 lb .127.0 lb • • '16 5/16" '25"20" CLEARANCE TO COMBUSTIBLE MATERIAL RECOMMENDED SERVICE CLEARANCE BOTTOM 0 UNIT WITH O.A. DAMPER/ECON. WITH 2 POS. DAMPER BACK SIDE 1" BACK SIDE 12" 30" LEFT SIDE 6" LEFT SIDE 36" 42" RIGHT SIDE 6" RIGHT SIDE 24" FRONT SIDE 12" FRONT SIDE 30" TOP 36" LIFTING LUG KITS FOUR REUSABLE LUGS IN EACH KIT ALLOW UNITS TO BE EASILY LIFTED TO ROOFTOP INSTALLATIONS. THESE LUGS SNAP (NO SCREWS REQUIRED) INTO SLOTS IN THE UNIT DRIP LIP CHANNEL. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 3 Sound Transit Track Power Substation TRANE' 1.5.5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:41 AM 38 7/8" ISOMETRIC - ROOF CURB (UNINSULATED) ACCESSORY DRAWING 56 1/8 ' NOTES: VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION ATTENTIONII CURB DRAWINGS ARE NOT INTENDED TO BE USED AS A BASIS TO CONSTRUCT, BUILD, MODIFY OR INSTALLATION.THE MANUFACTURER IS NOT RESPONSIBLE FOR THE UNAUTHORIZED USE OF THESE DRAWINGS AND EXPRESSLY DISCLAIMS ANY LIABILITY FOR DAMAGES RESULTING FROM SUCH UNAUTHORIZED USE SEE INSTALLER'S GUIDE 18-HE38D10-5. 14" 3" 41 7/8" 20" 19 1/2" SUPPLY 19 1/2" RETURN 4 3/4" TOP VIEW - ROOF CURB (UNINSULATED) —10 7/8"— ACCESSORY DRAWING TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 4 Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer rain hood Mist -limi- nator Relief damper Roofcurb 001000000 • 0000 .i-o. 000010 0 00000 0• .400 0moa oo 0 00000000 00 04040 O 00 400 ®Outside air dampers X Retum r air damp./ ers Required filter kit, order separately Retum Duct Economizer Unit Application Models A BAYEC0N101A 4TC*,WC*,YC*,DC* 20.125" *018-036 BAYECON 102A 4TC*,WC,YC, DC 24.375" *042-060 BAYECON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail re- garding job layout only.These drawings are not intended to be used as a basis to con- struct, build or modify the items depicted in the draw- ings. The manufacturer is not responsible for the unauthor- ized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Mixed Air Sensor Rain Hood Economizer A 8 C 0 E F BAYECON200AA 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201AA 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" 20 MANE' Sound Transit Track Power Substation 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:41 AM PACKAGEOCOOLNGIELECTRIC HEAT UNIT UNIT CONTROL BOX r r -• r • r UNT HEATER AREA POLARZED PLUG ELECTRIC HEATER CONTROL BOX r 1 Q 4 H(aBK) G I r I I I I —L AA sR))wI 41C(BR)W2 I I r- — — — 35P(RD) R �J I I I ( UNT LOW VOLTAGE AREA 1 FIELD PH PH 1 I 1 I I I t 14 1 `JUMPER O J� iPH IPH ..L o r w RI+�t1 JUMPER POWHi POWER ,. NOTES GROUND L..) �A TYPICAL THERMOSTAT WIRE 3 PH 3PH NOTE 1,& POWBT POWER UNIT HEATER COMMON FAN COMPRESSOR 1ST STAGE ELECTRIC HEAT 2ND STAGE ELECTRIC HEAT 24 VOLTS NOTES: I. FUSED DISCONNECT SITE, POWER WIRING AND GROUNDNG OF EQUIPMENT MUST COMPLY WITH CODES 2. BE SURE POWER SUPELY AGREESWITH EQUIPMENT ANO HEATER NAMEPLATE. 3. LOW VOLTAGE WRING TO BE 10 AWG MYNIMUM CONDUCTOR. 4. SEE HEATER NAMEPLATE FOR CURRENT RATING OF HEATER USED. S. SEE UNIT AND HEATER DIAGRAM FOR ELECTRICALCONNECTION DETALS. 5. JUMPER MUST BE CONNECTED BETWEEN 1 AND 2 FOR FAN TO OPERATE IN HEATING. 7. SOME THERMOSTATS PROVIDE'NE 'G' SIGNALIN THE COCUNG MODE ONLY. TO PROVIDE THE 'G' SGNAL IN THE HEATING MODE AN ACCESSORY RELAY IS REQUIRED. SEE FIG.3 FOR PROPER CONVECTIONS. S. FOR COOLING ONLY OMIT THE ELECTRIC HEATER, ASSOCATED POWER WIRES,AAD THE W SIGNAL THERMOSTAT WIRE. 9 FIG 4 DEMONSTRATESCONVECTION OF THE TWO STAGE ELECTRIC HEAT THERMOSTAT ACCESSORYOM.Y. FOR FLRTHER UNT CONNECTION DETAILS REFER TO THE OTHER FIGURES, 10. THE 41A(13R) WIRE IS FIRST STAGE ELECTRIC HEAT. IF THE ELECTRIC HEATER ACCESSORY HAS TWO HEATING STAGES THE 4IC(BR) WIRE IS SECONDSTAGE ELECTRIC HEAT, FIG. 1 SINGLE POWER ENTRY ACCESSORY CONNECTIONS TO ECONOMIZER FACTORY FIELD WIRES NSTALLED FIG2 ECONOMIZER ACCESSORY CONVECTIONS PROVICED (NOT APPLICABLE TO THE TCMF MODELS) UNR CONTROL BOX UNIT HEATER AREA TO COMPR. CONTACTOR FACTORY PROVIDED FIELD CONNECTED ELECTRIC HEATERVVIRES CONTROL 1 35E 36E BL) B HrE(Vy I 47E(BK) 47A(BK)G _ _ rr — _ _ _57 I EMDryR) R'f4A(YL')Y I 1 r r---- -- — — IV —' SPE VEATFR FUSES ��I-440 I I-- 41A(191)WI — UNIT LOW I I I r r - - 41C(BR)W2 VOLTAGE AMAI I I I I r-- sL 35A(RD) R I I ACCESEQRY KIT I I UN TLOW VO AGE AREA—Tj II1111 I I I I I I FIELD INSTALLED JUMPER `v' I PH POWER 3 PHP SINGLEPOWER ENTRY GROUND WIRE = VER M111©©i„�%013 'TYPICAL2STAGE THERMOSTAT FIG.3 AUTO CHANGEOVER THERMOSTAT CONNECTIONS NOTE 7 1 FIG. 4 TWO STAGE ELECTRIC HEAT CONVECTIONS 36B(BL)B J? I—�? 47A(BK) G UNIT VOLTAGE AREA LOW NOTE 10 — — — -FL 41A(BR)W1 ' r- - - —R— 41C(BR) W2 Q r 44A(YL) Y J p r 41A(BR)Wt 1 - JL 41 C(B R) W 2 UNIT LOW VOLTAGEAIFA 1 1 r �- 1 I I I — 35A(RD)R 111I I r - - — I BAY24x542 IiL—I— — J_i_—i--_ 41 H VI0YlvnwxCIN FIELD INSTALLED TYPICAL -THERMOSTAT JUMPER I I rl FIELD J I INSTALLED al JUMPER DD©00 TYPICAL THERMOSTAT INTER-COMPONTENT WRING 24V. FACTORY LINE V. WIRING 24V. FIELD LINE V. WIRING WIRE COLORDESIGNATION ABBR COLOR ABBR COLOR BK BLACK PR PURPLE BL BLUE RD RED BR BROWN WH WHRE GR GREEN yL YELLOW OR ORANGE TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 5 Design Weather Parameters & MSHGs ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM Design Parameters: City Name Location Latitude .. w Longitude Elevation ._. Summer Design Dry -Bulb Summer Coincident Wet -Bulb Summer Daily Range .____... _.. Winter Design Dry -Bulb . ... . Winter Design Wet -Bulb . . Atmospheric Clearness Number Average Ground Reflectance ., Soil Conductivity ___ ... Local Time Zone (GMT +/- N hours) Consider Daylight Savings Time Simulation Weather Data ._ Current Data is Design Cooling Months Design Day Maximum Solar Heat Gains (The MSHG values are expressed in BTU/(hr-ft2) ) __ Seattle IAP Washington 47.5 Deg. 122.3 Deg. 449.0 ft 85.0 °F 65.0 °F 18.3 °F 23.0 °F .19.2 °F 1.05 0.20 0.800 BTU/(hr-ft-°F) 8.0 hours No noneN/A 2001 ASHRAE Handbook January to December Month N NNE NE ENE E ESE SE SSE S January 16.1 16.1 16.1 53.6 129.0 183.4 230.6 251.9 257.9 February 21.4 21.4 36.9 112.4 175.7 229,5 253.9 260.9 262.5 March 27.1 27.1 91.8 159.2 217.2 242.8 253.0 243.7 238.0 April 33.0 68.6 137.1 195.3 225.5 239.1 225.9 204.4 192.1 May 37.3 105.1 162.3 210.6 229.9 225.1 199.4 170.1 154.1 June 51.1 117.6 171.4 213.7 226.9 216.7 186.9 154.0 137.4 July 39.4 104.2 161.3 207.5 222.7 220.4 195.6 165.7 151.0 August 34.8 65.4 134.3 187.4 219.3 230.1 218.4 197.6 186.3 September 28.2 28.2 86.3 145.2 203.9 232.3 242.6 235.6 227.9 October 22.1 22.1 36.4 105.4 171.4 216.2 245.2 253.6 252.2 November 16.3 16.3 16.3 56.6 123.7 184.3 224.4 244.6 251.3 December 13.7 13.7 13.7 34.5 105.1 162.2 212.5 238.1 245.0 Month SSW SW WSW W WNW NW NNW HOR Mult January 251.9 227.1 188.2 121.9 59.5 16.1 16.1 92.5 1.00 February . 262.5 255.6 227.5 179.4 105.7 40.2 2.1.4 147.6 1.00 March 244.1 251.9 247.4 210.6 163.3 87.7 27.1 199.6 1.00 April 204.0 224.1 238.5 228.6 194.9 132.9 70.0 238.0 1.00 May 169.6 197.8 223.8 231.1 208.5 165.6 103.6 259.3 1.00 June 152.9 185.9 214.0 228.2 209.8 175.3 113.9 265.4 1.00 July 164.4 194.2 217.4 226.5 202.6 164.4 101.1 257.6 1.00 August 197.1 216.1 229.9 220.5 187.9 129.3 68.8 234.8 1.00 September 235.7 242.6 232.9 203.5 146.7 86.2 28.2 191.4 1.00 October 252.2 242.3 219.1 167.3 108.3 30.0 22.1 144.2 1.00 November 245.2 225.7 182.6 125.7 52.6 16.3 16.3 91.1 1.00 December 235.2 212.0 163.5 105.1 33.6 13.7 13.7 69.9 1.00 ult. = User -defined solar multiplier factor. Hourly Analysis Program v4.60 Page 1 of 1 Schedule Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 24/7 Sched (Fractional) Hourly Profiles: 1:Profile One Hour 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Value 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Assignments: Design Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1 1 1 1 1 1 1 1 1 1 1 1 Monday 1 1 1 1 1 1 1 1 1 1 1 1 Tuesday 1 1 1 1 1 1 1 1 1 1 1 1 Wednesday 1 1 1 1 1 1 1 1 1 1 1 1 Thursday 1 1 1 1 1 1 1 1 1 1 1 1 Friday 1 1 1 1 1 1 1 1 1 1 1 1 Saturday 1 1 1 1 1 1 1 1 1 1 1 1 Sunday 1 1 1 1 1 1 1 1 1 1 1 1 Holiday 1 1 1 1 1 1 1 1 1 1 1 1 Hourly Analysis Program v4.60 Page 1 of 1 Wall Constructions ST TO19 2013-018 CDi Engineers 08/29/2013 04:53Plvi Signal House Wall Wall Details Outside Surface Color Absorptivity w...,. Overall U-Value Wall Layers Details (Inside to Outside Dark 0.900 0.080 BTU/(hr-ft2 °F) Layers Thickness in Density Ib/ft Specific Ht. BTU / (Ib - °F) R-Value (hr-ft2-°F)/BTU Weight Ib/ft' Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 2" batt insulation 2.000 0.5 0.20 6.41026 0.1 1" Poly insulation 1.000 2.0 0.22 5.00000 0.2 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 12.42847 3.0 TPSS Wall Wall Details Outside Surface Color Absorptivity .... ..... Overall U-Value Wall Lavers Details (Inside to Outside Dark 0.900 0.094 BTU/(hr-ft2 °F) Layers Thickness in Density ib/ft3 Specific Ht. BTU / (Ib - °F) R-Value (hr-ft= °F)/BTU Weight Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 3" batt insulation 3.000 0.5 0.20 9.61538 0.1 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 10.63359 2.9 Hourly Analysis Program v4.60 Page 1 of 1 Roof Constructions ST TO19 2013-018 CDi Engineers 08/29/2013 04:54PM Signal House Metal Roof Roof Details Outside Surface Color Absorptivity ........ ,.. Overall U-Value Roof Lavers Details (Inside to Outside Medium 0.675 0.080 BTU/(hr-ft2 °F) Layers Thickness in Density Ib/ft' Specific Ht. BTU / (lb - °F) R-Value (hr-f 3 °F)/BTU Weight Iblft' Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 Poly rigid insulation 1.000 2.0 0.22 5.00000 0.2 batt insulation 2.000 0.5 0.20 6.41026 0.1 22 gage steel deck 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 12.42847 3.0 TPSS Metal Roof Roof Details Outside Surface Color Absorptivity ... Overall U-Value Roof Lavers Details (Inside to Outside Medium 0.675 0.094 BTU/(hr-ft'-°F) Layers Thickness in Density Ib/ft' Specific Ht. BTU / (lb - °F) R-Value (hr-ftz--°F)/BTU Weight Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 batt insulation 3.000 0.5 0.20 9.61538 0.1 22 gage steel deck 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 10.63359 2.9 Hourly Analysis Program v4.60 Page 1 of 1 Door Constructions ST 7019 2013-018 CDi Engineers 08/29/2013 04:54PM Double Metal Door Door Details: Gross Area ..,. ... Door U-Value 48.0 ft2 0.652 BTU/(hr-ft - F) Glass Details: Glass Area 0.0 ft' Glass U-Value.., .._ 0.580 BTU/(hr-ft2°F) Glass Shade Coefficient 0.880 Glass Shaded All Day? No Single Metal Door Door Details: Gross Area .. Door U-Value ............... 24.0 ft2 0.652 BTU/(hr-ft2F) Glass Details: Glass Area ... .. 0.0 ft2 Glass U-Value 0.580 BTU/(hr-ft2°F) Glass Shade Coefficient 0.880 Glass Shaded All Day? ... ._. No Hourly Analysis Program v4.60 Page 1 of 1 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM Signal Hse e-w 1. General Details: Floor Area ,... ... Avg. Ceiling Height Building Weight 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 0.0 OA Requirement 2 0.00 Space Usage Defaults .... _... ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 200.0 ft' 9.5 ft 130.0 lb/ft' CFM/person CFM/ft' Recessed (Unvented) 1.50 W/ft' ........ 1.00 24/7 Sched 0.00 W/ft' None 39.50 W/ft' 24/7 Sched 2.4. People: Occupancy Activity Level.. Sensible ..,..... Latent . ..._ _. Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent .. Schedule ... .... Exp. Wall Gross Area (ft') Window 1 Qty. Window 2 Qty. Door 1 Qty. W 145.0 0 0 0 S 72.5 0 0 0 E 145.0 0 0 1 N 72.5 0 0 0 3.1. Construction Types Wall Type 3.2. Construction Types Wall Type 3.3. Construction Types Wall Type Door Type 3.4. Construction Types Wall Type 4. Roofs, Skylights: for Exposure W Signal House Wall for Exposure S for Exposure E Signal House Wall Signal House Wall Single Metal Door for Exposure N Signal House Wati Exp. Roof Gross Area (ft') Roof Slope (deg.) Skylight Qty. H 200.0 0 0 4.1. Construction Types for Exposure H Roof Type Signal House Metal Roof 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 CFM 0.00 CFM .........0.0 Person User defined 250.0 BTU/hr/person 200.0 BTU/hr/person None 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v4.60 Page 1 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 2 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM Signal Hse n-s 1. General Details: Floor Area .. Avg. Ceiling Height Building Weight ,.,. ..... 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 ,. ... ... 0.0 OA Requirement 2 ..... ......... ._... 0.00 Space Usage Defaults . ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 200.0 ft2 .9.5 ft 130.0 lb/ft2 CFM/person CFM/ft2 Recessed (Unvented) _. 1.50 W/ft2 .. 1.00 24/7 Sched 0.00 W/ft2 None 45.05 W/ft2 2417 Sched 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 72.5 0 0 0 S 145.0 0 0 0 E 72.5 0 0 1 N 145.0 0 0 0 3.1. Construction Types for Exposure W Wall Type 3.2. Construction Types for Exposure S Wall Type 3.3. Construction Types for Exposure E Wall Type Door Type Signal House Wall Signal House Wall ............. Signal House Wall Single Metal Door 3.4. Construction Types for Exposure N Wall Type 4. Roofs, Skylights: Signal House Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 200.0 0 0 4.1. Construction Types for Exposure H Roof Type .. Signal House Metal Roof 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 CFM 0.00 CFM 0.0 Person User defined ......_.....250.0 BTU/hr/person 200.0 BTU/hr/person None 0 BTU/hr _. None ,.,... .0 BTU/hr None Hourly Analysis Program v4.60 Page 3 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 4 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM Small Signal House 1. General Details: Floor Area 36.0 ft2 Avg. Ceiling Height .. 7.5 ft Building Weight ... ...... 130.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage .. ...,...... ... User -Defined OA Requirement 1 0.0 CFM/person OA Requirement 2 0.00 CFM/ft2 Space Usage Defaults ........_ ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type .,. Recessed (Unvented) Occupancy .. 0.0 Person Wattage _ . 400.0 Watts Activity Level User defined Ballast Multiplier . 1.00 Sensible ....250.0 BTU/hr/person Schedule 24/7 Sched Latent ... „ ,.... 200.0 BTU/hr/person Schedule None 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule None Latent .. 0 BTU/hr Schedule None _ 5004.0 Watts 24/7 Sched Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 45.0 0 0 0 S 45.0 0 0 0 E 45.0 0 0 1 N 45.0 0 0 0 3.1. Construction Types for Exposure W Wall Type Signal House Wall 3.2. Construction Types for Exposure S Wall Type 3.3. Construction Types for Exposure E Wall Type Door Type 3.4. Construction Types for Exposure N Wall Type 4. Roofs, Skylights: Signal House Wall Signal House Wall Single Metal Door Signal House Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 36.0 0 0 4.1. Construction Types for Exposure H Roof Type ... Signal House Metal Roof 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 CFM 0.00 CFM Hourly Analysis Program v4.60 Page 5 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 6 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM TPSS e-w 1. General Details: Floor Area .,, ... 790.0 ft2 Avg. Ceiling Height ... 9.6 ft Building Weight .._ 130.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 ._ 0.0 CFM/person OA Requirement 2 0.00 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: Fixture Type __. . ... Recessed (Unvented) Wattage 1.50 W/ft2 Ballast Multiplier ..._ 1.00 Schedule _. ._. ,.. . 2417 Sched 2.2. Task Lighting: Wattage ,..,. Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 0.00 W/ft2 None 32230.0 Watts 24/7 Sched 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft=) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 470.0 0 0 0 S 138.0 0 0 1 E 470.0 0 0 0 N 138.0 0 0 2 3.1. Construction Types Wall Type 3.2. Construction Types Wall Type ,.. ... Door Type 3.3. Construction Types Wall Type 3.4. Construction Types Wall Type Door Type 4. Roofs, Skylights: for Exposure W TPSS Wall for Exposure S TPSS Wall Single Metal Door for Exposure E for Exposure N TPSS Wall TPSS Wall Double Metal Door Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 790.0 0 0 4.1. Construction Types for Exposure H Roof Type 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. TPSS Metal Roof _ 0.00 CFM/ft2 0.00 CFM 0.00 CFM 0.0 Person User defined ,250.0 BTU/hdperson 200.0 BTU/hr./person None 0 BTU/hr ,,, None 0 BTU/hr None Hourly Analysis Program v4.60 Page 7 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type ... Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 8 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM TPSS n-s 1. General Details: Floor Area 790.0 ft2 Avg. Ceiling Height ._. 9.6 ft Building Weight 130.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 .. 0.0 CFM/person OA Requirement 2 0.00 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: Recessed (Unvented) _..... __ 1.50 W/ft2 1.00 24r7 Sched 0.00 W/ft2 None 32230.0 Watts 24/7 Sched 2.4. People: Occupancy Activity Level Sensible._ ..__. Latent ... Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent ... Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 138.0 0 0 1 S 518.0 0 0 0 E 138.0 0 0 1 N 518.0 0 0 0 3.1. Construction Types Wall Type Door Type 3.2. Construction Types Wall Type 3.3. Construction Types Wall Type Door Type 3.4. Construction Types Wall Type 4. Roofs, Skylights: for Exposure W TPSS Wall Single Metal Door for Exposure S for Exposure E for Exposure N TPSS Wall TPSS Wall Double Metal Door TPSS Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 790.0 0 0 4.1. Construction Types for Exposure H TPSS Metal Roof Roof Type 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM/ft2 0.00 CFM 0.00 CFM 0.0 Person User defined 250.0 BTU/hr/person 200.0 BTU/hr/person None ..... ...... 0 BTU/hr None .......0 BTU/hr None Hourly Analysis Program v4.60 Page 9 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 10 of 10 Signal House Split Sys e-w Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:55PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones 2. System Components: Ventilation Air Data: Airflow Control ................. . Ventilation Sizing Method Unocc. Damper Position _. Damper Leak Rate Outdoor Air CO2 Level Central Cooling Data: Supply Air Temperature Coil Bypass Factor Cooling Source Schedule Capacity Control Central Heating Data: Supply Temperature Heating Source Schedule Capacity Control Supply Fan Data: Fan Type Configuration Fan Performance Overall Efficiency Fan Control Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Return Air Via 3. Zone Components: Space Assignments: Signal House Split Sys e-w Split AHU Single Zone CAV Constant Ventilation Airflow Sum of Space OA Airflows . Closed 400 ppm _. 58.0 °F 0.100 Air -Cooled DX JFMAMJJASOND .. Cycled or Staged Capacity - Fan On 95.0 °F Electric Resistance JFMAMJJASOND Cycled or Staged Capacity - Fan On Forward Curved __. Draw-thru 0.00 in wg 54 % 1-speed fan, cooling and heating 0 0 Ducted Return Zone 1: Signal House Zn Signal Hse e-w x1 Thermostats and Zone Data: Zone Cooling T-stat: Occ. Cooling T-stat: Unocc. Heating T-stat: Occ. Heating T-stat: Unocc. T-stat Throttling Range Diversity Factor Direct Exhaust Airflow ... Direct Exhaust Fan kW Thermostat Schedule Unoccupied Cooling is .. Supply Terminals Data: Zone Terminal Type Minimum Airflow Zone Heating Units: Zone Zone Heating Unit Type All 80.0 80.0 70.0 65.0 1.50 100 0.0 0.0 Sample Schedule Available °F °F °F °F °F CFM kW All Diffuser 0.00 CFM/person All None Hourly Analysis Program v4.60 Page 1 of 2 Signal House Split Sys e-w Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:55PM Zone Unit Heat Source Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Cooling Supply Temperature Supply Fan Airflow ... Ventilation Airflow Heating Supply Temperature Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T Safety Factors: Cooling Sensible Cooling Latent Heating Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method Electric Resistance JFMAMJJASOND . 58.0 °F 1333.0 CFM 0.0 CFM 95.0 °F 10.0 °F 20.0 °F 5 0 % Sum of space airflow rates Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1333.0 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load . 31.0 MBH Design OAT 95.0 °F Equipment Sizing .. . . . Auto -Sized Capacity Oversizing Factor 0 % ARI Performance Rating .._ 11.000 EER DX System Configuration 2-stage compression, separate circuits Conventional Cutoff OAT 55.0 °F Low Temperature Operation -. .. Used Low Temperature Cutoff OAT 0.0 °F Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM Air System Information Air System Name Signal House Split Sys e-w Equipment Class ._. ., SPLT AHU Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Central Cooling Coil Sizing Data Total coil load ._. Total coil load.. Sensible coil Toad Coil CFM at Jul 1500 .. Max block CFM ... Sum of peak zone CFM Sensible heat ratio _.. ft2/Ton ...... BTU/(hr-ft2) Water flow @ 10.0 °F rise 2.6 Tons __......_. 31.0 MBH 31.0 MBH 1333 CFM 1333 CFM 1333 CFM 1.000 77.3 155.2 N/A Central Heating Coil Sizing Data Max coil load. .. 3.2 MBH Coil CFM at Des Htg 1333 CFM Max coil CFM _... 1333 CFM Water flow @ 20.0 °F drop ._NIA Supply Fan Sizing Data Actual max CFM Standard CFM . . Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2.. ,...,.. 1333 CFM ..1312 CFM 6.66 CFM/ft2 0 CFM , 0.00 CFM/ft2 Number of zones Floor Area Location Calculation Months._. Sizing Data ,. 200.0 ft2 Seattle IAP, Washington Load occurs at ....... OADB/WB ...... . Entering DB / WB Leaving DB / WB . . _. ... Coil ADP Bypass Factor Resulting RH . __. ...._ Design supply temp. Zone T-stat Check Max zone temperature deviation Load occurs at ... BTU/(hr-ft2) Ent. DB / Lvg DB . Fan motor BHP Fan motor kW Fan static _... CFM/person ... ....Jan to Dec ,., Calculated Jul 1500 85.0 / 65.0 81.6 / 48.7 ...59.7/37.9 57.2 0.100 ...., 0 58.0 0 of 1 0.1 °F °F °F °F °F OK °F Des Htg 15.9 70.4 / 72.7 °F 0.00 BHP 0.00 kW 0.00 in wg 0.00 CFM/person Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CD' Engineers 08/29/2013 04:57PM Air System Information Air System Name ._. .. Signal House Split Sys e-w Equipment Class SPLT AHU Air System Type . .. SZCAV Sizing Calculation Information Zone and Space Sizing Method: Number of zones Floor Area _. _. 200.0 ft2 Location .,. Seattle IAP, Washington Zone CFM....... .. Sum of space airflow rates Calculation Months .,. Space CFM.,, _ ..,. Individual peak space loads Zone Sizing Data Sizing Data _ 1 .Jan to Dec ... Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Row (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft' Signal House Zn 31.2 1333 1333 Jul 1500 3.0 200.0 6.66 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Signal House Zn Signal Hse e-w 1 31.2 Jul 1500 1333 3.0 200.0 6.66 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft' - - Wall Transmission 411 ft' 1055 - 411 ft' 1554 - Roof Transmission 200 ft' 621 - 200 ft' 756 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 24 ft' 25 - 24 ft' 735 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 7900 W 26952 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1484 0 0% 0 0 » Total Zone Loads - 31161 0 - 3046 0 Zone Conditioning - 31031 0 - 3184 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1333 CFM 0 - 1333 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 1333 CFM 0 - 1333 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 31031 0 - 3184 0 Central Cooling Coil - 31031 0 - 0 0 Central Heating Coil - 0 - - 3184 - » Total Conditioning - 31031 0 - 3184 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " Signal Hse a-w' IN ZONE " Signal House Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F OCCUPIED T-STAT 80.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 411 ft2 1055 - 411 ft2 1554 - Roof Transmission 200 ft2 621 - 200 ft2 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 25 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 7900 W 26952 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1484 0 0% 0 0 » Total Zone Loads - 31161 0 - 3046 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " Signal Hse e-w " IN ZONE " Signal House Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2 °F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 145 0.080 - 637 - 548 S EXPOSURE WALL 73 0.080 - 183 - 274 E EXPOSURE WALL 121 0.080 - 164 - 458 DOOR 24 0.652 - 25 - 735 N EXPOSURE WALL 73 0.080 - 71 - 274 H EXPOSURE ROOF 200 0.080 - 621 - 756 Hourly Analysis Program v4.60 Page 4 of 4 Signal House Split Sys n-s Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones Signal House Split Sys n-s Split AHU Single Zone CAV 1 2. System Components: Ventilation Air Data: Airflow Control ......._ Constant Ventilation Airflow Ventilation Sizing Method ...Sum of Space OA Airflows Unocc. Damper Position Closed Damper Leak Rate _.. 0 % Outdoor Air CO2 Level 400 ppm Central Cooling Data: Supply Air Temperature 58.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control . Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source .. Electric Resistance Schedule _.. JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type . Forward Curved Configuration Draw-thru Fan Performance ._ 0.00 in wg Overall Efficiency 54 % Fan Control ... 1-speed fan, cooling and heating Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Return Air Via 3. Zone Components: Space Assignments: .0 % 0 % Ducted Return Zone 1: Signal House Zn Signal Hse n-s x1 Thermostats and Zone Data: Zone All Cooling T-stat: Occ. ,.. .80.0 °F Cooling T-stat: Unocc. 80.0 °F Heating T-stat: Occ. 70.0 °F Heating T-stat: Unocc. 65.0 °F T-stat Throttling Range ...... 1.50 °F Diversity Factor 100 % Direct Exhaust Airflow 0.0 CFM Direct Exhaust Fan kW .-. 0.0 kW Thermostat Schedule ... ... Sample Schedule Unoccupied Cooling is Available Supply Terminals Data: Zone All Terminal Type Diffuser Minimum Airflow .. 0.00 CFM/person Zone Heating Units: Zone . . All Zone Heating Unit Type None Hourly Analysis Program v4.60 Page 1 of 2 Signal House Split Sys n-s Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Zone Unit Heat Source ... Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow ... Heating Supply Temperature Hydronic Sizing Specifications: Chilled Water Delta-T _. Hot Water Delta-T Safety Factors: Cooling Sensible Cooling Latent Heating .__. Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method Electric Resistance JFMAMJJASOND 58.0 °F 1499.5 CFM 0.0 CFM 95.0 °F 10.0 °F _ 20.0 °F 5 % .0 % 0 Sum of space airflow rates Individual peak space Toads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1499.5 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load 34.9 MBH Design OAT.... 95.0 °F Equipment Sizing .. .. Auto -Sized Capacity Oversizing Factor , .., . 0 ARI Performance Rating 11.000 EER DX System Configuration 2-stage compression, separate circuits Conventional Cutoff OAT 55.0 °F Low Temperature Operation Used Low Temperature Cutoff OAT 0.0 °F Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name ... Signal House Split Sys n-s Equipment Class _,....... _. SPLT AHU Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM. _.._ Sum of space airflow rates Space CFM Individual peak space loads Central Cooling Coil Sizing Data Total coil Toad Total coil load . . Sensible coil load Coil CFM at Jul 1400........... Max block CFM. Sum of peak zone CFM Sensible heat ratio .__..__ . ft2/Ton BTU/(hr-ft2) ,.,.. Water flow @ 10.0 °F rise 2.9 34.9 34.9 1500 1500 1500 1.000 68.8 174.5 N/A Tons MBH MBH CFM CFM CFM Central Heating Coil Sizing Data Max coil load...... 3.4 MBH Coil CFM at Des Htg .. ... . 1500 CFM Max coil CFM. _. 1500 CFM Water flow @ 20.0 °F drop ..... N/A Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2 1500 CFM 1475 CFM 7.50 CFM/ft2 0 CFM 0.00 CFM/ft2 Number of zones .... Floor Area Location Calculation Months Sizing Data Load occurs at OADB/WB Entering DB / WB Leaving DB / WB Coil ADP Bypass Factor Resulting RH Design supply temp. Zone T-stat Check Max zone temperature deviation _ 200.0 ft2 Seattle IAP, Washington Load occurs at BTU/(hr-ft2) Ent. DB / Lvg DB Fan motor BHP Fan motor kW Fan static CFMlperson .Jan to Dec ...,,Calculated Jul 1400 84.5 / 64.8 _. 81.6 / 48.8 59.7 / 38.0 57.3 _. 0.100 58.0 0of1 0.1 °F °F °F °F °F OK °F Des Htg 17.0 70.6/72.7 °F 0.00 BHP 0.00 kW 0.00 in wg 0.00 CFM/person Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name . ... Signal House Split Sys n-s Equipment Class SPLT AHU Air System Type , ..__ SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Space CFM Zone Sizing Data Number of zones ... 1 Floor Area 200.0 ft2 Location ...... ._..._ _ Seattle IAP, Washington Sum of space airflow rates Calculation Months Individual peak space Toads Sizing Data .. _. ... Jan to Dec _Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft=) Zone CFM/ft' Signal House Zn 35.1 1500 1500_ Jul 1400 3.0 200.0 7,50 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft°) Space CFM/ft° Signal House Zn Signal Hse n-s 1 35.1 Jul 1400 1500 3.0 200.0 7.50 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OA DB / WB 84.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 411 ft2 914 - 411 ft2 1554 - Roof Transmission 200 ft2 692 - 200 ft2 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 18 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 9010 W 30739 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1669 0 0% 0 0 » Total Zone Loads - 35055 0 - 3046 0 Zone Conditioning - 34895 0 - 3400 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1500 CFM 0 - 1500 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 1500 CFM 0 - 1500 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 34895 0 - 3400 0 Central Cooling Coil - 34895 0 - 0 0 Central Heating Coil - 0 - - 3400 - » Total Conditioning - 34895 0 - 3400 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " Signal Hse n-s' IN ZONE " Signal House Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OA DB / WB 84.5 °F / 64.8 °F OCCUPIED T-STAT 80.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft2 - - Wall Transmission 411 ft2 914 - 411 ft2 1554 - Roof Transmission 200 ft2 692 - 200 ft2 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 18 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 9010 W 30739 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1669 0 0% 0 0 » Total Zone Loads - 35055 0 - 3046 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " Signal Hse n-s " IN ZONE " Signal House Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2 °F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 73 0.080 - 255 - 274 S EXPOSURE WALL 145 0.080 - 448 - 548 E EXPOSURE WALL 49 0.080 - 67 183 DOOR 24 0.652 - 18 - 735 N EXPOSURE WALL 145 0.080 - 143 - 548 H EXPOSURE ROOF 200 0.080 - 692 - 756 Hourly Analysis Program v4.60 Page 4 of 4 Signal House thru wall Input Data Project Name: ST T019 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type ... Number of zones Signal House thru wall ,... Undefined ., ... Single Zone CAV 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method .. Sum of Space OA Airflows Unocc. Damper Position Closed Damper Leak Rate ... 0 % Outdoor Air CO2 Level 400 oc Supply Fan Data: Fan Type .... Forward Curved Configuration Draw-thru 0.00 in wg 54 % Fan Performance Overall Efficiency Duct System Data: Supply Duct Data: Duct Heat Gain ... Duct Leakage Return Duct or Plenum Data: Retum Air Via 3. Zone Components: Space Assignments: .0 0 . Ducted Return Zone 1: Signal House Zn Small Signal House x1 Thermostats and Zone Data: Zone. All Cooling T-stat: Occ. 80.0 °F Cooling T-stat: Unocc. 80.0 °F Heating T-stat: Occ. 70.0 °F Heating T-stat: Unocc. 65.0 °F T-stat Throttling Range 1.50 °F Diversity Factor . . 100 % Direct Exhaust Airflow. 0.0 CFM Direct Exhaust Fan kW 0.0 kW Thermostat Schedule ,. Sample Schedule Unoccupied Cooling is _. __. __ Available Supply Terminals Data: Zone _ .. All Terminal Type ._. Diffuser Minimum Airflow 0.00 CFM/person Zone Heating Units: Zone All Zone Heating Unit Type None Zone Unit Heat Source Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Supply Fan Airflow Ventilation Airflow .. Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T .Any JFMAMJJASOND .. 851.5 CFM 0.0 CFM .. 10.0 °F 20.0 °F Safety Factors: Cooling Sensible .. 5 Hourly Analysis Program v4.60 Page 1 of 2 Signal House thru wall Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Cooling Latent ... Heating .......... ............ Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method 0 0 Sum of space airflow rates Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 851.5 - - 5. Equipment Data No Equipment Data required for this system. Hourly Analysis Program v4.60 Page 2 of 2 . Air System Sizing Summary for Signal House thru wall Project Name: ST TO19 2013-018 08/29/2013 Prepared by: CDi Engineers 04:59PM Air System Information Air System Name .. Signal House thru wall Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM individual peak space loads Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft= 851 CFM _.838 CFM ....23.65 CFM/ft2 Number of zones Floor Area Location ... ..... Calculation Months Sizing Data .. Fan motor BHP Fan motor kW Fan static 1 Seattle IAP, Washington ...Jan to Dec _. Calculated 0.00 BHP 0.00 kW ..... 0.00 in wg Outdoor Ventilation Air Data' Design airflow CFM 0 CFM CFM/person . _. ... 0.00 CFM/person CFM/ft2 0.00 CFM/ft2 Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Signal House thru wail Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name Signal House thru wall Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM .... Space CFM Zone Sizing Data Sum of space airflow rates Individual peak space loads Number of zones .., Floor Area 36.0 ft2 Location Seattle IAP, Washington Calculation Months Sizing Data 1 Jan to Dec Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Signal House Zn 19.9 851 851 Jul 1500 1.5 36.0 23.65 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft°) Space CFM/ft= Signal House Zn Small Signal House 1 19.9 Jul 1500 851 1.5 36.0 23.65 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Signal House thru wall Project Name: ST TO19 2013-018 Prepared by: CDI Engineers 08/29/2013 04:59PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' - - 0 ft' - - Wall Transmission 156 ft' - - 156 ft' 590 - Roof Transmission 36 ft' - - 36 ft' 136 - Window Transmission 0 ft' - - 0 ft' 0 - Skylight Transmission 0 ft' - - 0 ft2 0 - Door Loads 24 ft' - - 24 ft2 735 - Floor Transmission 0 ft' - - 0 ft' 0 - Partitions 0 ft' - - 0 ft' 0 - Ceiling 0 ft' - - 0 ft' 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 5% / 0% - - 0% 0 0 » Total Zone Loads - - - - 1462 0 Zone Conditioning - - - - 45 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Plenum Lighting Load 0% - - 0 0 - Return Fan Load - - - 851 CFM 0 - Ventitation Load - - - 0 CFM 0 0 Supply Fan Load - - - 851 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - » Total System Loads - - - - 45 0 » Total Conditioning - - - - 0 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Signal House thru wall Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " Small Signal House " IN ZONE " Signal House Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F OCCUPIED T-STAT 80.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTUIhr) (BTUIhr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 156 ft2 384 - 156 ft2 590 - Roof Transmission 36 ft2 112 - 36 ft2 136 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 25 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 400 W 1364 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 5004 W 17072 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 948 0 0% 0 0 » Total Zone Loads - 19905 0 - 1462 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " Small Signal House " IN ZONE " Signal House Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2 °F)) Coeff. (BTU/hr) (BTUIhr) (BTU/hr) W EXPOSURE WALL 45 0.080 - 198 - 170 S EXPOSURE WALL 45 0.080 - 114 - 170 E EXPOSURE WALL 21 0.080 - 29 - 79 DOOR 24 0.652 - 25 - 735 N EXPOSURE WALL 45 0.080 - 44 - 170 H EXPOSURE ROOF 36 0.080 - 112 - 136 Hourly Analysis Program v4.60 Page 4 of 4 Sub -Station Package E-W Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM • 1. General Details: Air System Name Equipment Type Air System Type Number of zones 2. System. Components: Ventilation Air Data: Airflow Control . Ventilation Sizing Method Unocc. Damper Position Damper Leak Rate ... Outdoor Air CO2 Level Central Cooling Data: Supply Air Temperature .. Coil Bypass Factor Cooling Source ._. Schedule Capacity Control Central Heating Data: Supply Temperature Heating Source Schedule Capacity Control Supply Fan Data: Fan Type Configuration Fan Performance Overall Efficiency Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Retum Air Via 3. Zone Components: Space Assignments: ..._Sub -Station Package E-W ..... Undefined _.__. Single Zone CAV Constant Ventilation Airflow Sum of Space OA Airflows Closed 400 ppm 58.0 °F 0.100 Any JFMAMJJASOND Cycled or Staged Capacity - Fan On 95.0 °F .. Any JFMAMJJASOND Cycled or Staged Capacity - Fan On Forward Curved Draw-thru 0.00 in wg 0 0 Ducted Return Zone 1: Sub Station Zn TPSS e-w x1 Thermostats and Zone Data: Zone Cooling T-stat: Occ. Cooling T-stat: Unocc. Heating T-stat: Occ. Heating T-stat: Unocc. T-stat Throttling Range Diversity Factor Direct Exhaust Airflow Direct Exhaust Fan kW Thermostat Schedule Unoccupied Cooling is Supply Terminals Data: Zone Terminal Type Minimum Airflow Zone Heating Units: Zone Zone Heating Unit Type .... All 90.0 °F 90.0 °F 70.0 °F 65.0 °F 1.50 °F 100 % 0.0 CFM 0.0 kW Sample Schedule Available All Diffuser 0.00 CFM/person All None Zone Unit Heat Source .Any Hourly Analysis Program v4.60 Page 1 of 2 Sub -Station Package E-W Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Zone Heating Unit Schedule.. 4. Sizing Data (Computer -Generated): System Sizing Data: Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T Safety Factors: Cooling Sensible. Cooling Latent Heating Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method 5. Equipment Data No Equipment Data required for this system. JFMAMJJASOND 10.0 °F _20.0 °F 0 0 0 .. Sum of space airflow rates Individual peak space loads Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name . Sub -Station Package E-W Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM ... .-..... Sum of space airflow rates Space CFM Individual peak space loads Number of zones Floor Area Location ,_..... . Calculation Months ... . Sizing Data 1 790.0 ft2 Seattle IAP, Washington Jan to Dec Calculated Central Cooling Coil Sizing Data Total coil load __.... ... 9.8 Tons Load occurs at Jul 1500 Total coil load 117.3 MBH OA DB / WB .85.0 / 65.0 °F Sensible coil load 117.3 MBH Entering DB / WB .... .91.8 / 53.2 °F Coil CFM at Jul 1500 3470 CFM Leaving DB / WB ......60.0 / 38.1 °F Max block CFM ... 3470 CFM Coil ADP 56.5 °F Sum of peak zone CFM 3470 CFM Bypass Factor _ 0.100 Sensible heat ratio . 1.000 Resulting RH ..._. ft2/Ton . 80.8 Design supply temp. 58.0 °F BTU/(hr-ft2) 148.5 Zone T-stat Check . 0 of 1 OK Water flow @ 10.0 °F rise 23.47 gpm Max zone temperature deviation 0.3 °F Central Heating Coil Sizing Data Max coil load 12.0 MBH Load occurs at Des Htg Coil CFM at Des Htg 3470 CFM BTU/(hr-ft2) 15.1 Max coil CFM 3470 CFM Ent. DB / Lvg DB 69.8 / 73.1 °F Water flow @ 20.0 °F drop 1.20 gpm Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft2 3470 CFM 3414 CFM 4.39 CFM/ft2 Fan motor BHP Fan motor kW Fan static. 0.00 BHP 0.00 kW 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/person .. 0.00 CFM/person CFM/ft2 0.00 CFM/ft2 Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 08/29/2013 Prepared by: CDi Engineers 04:59PM Air System Information Air System Name Sub -Station Package E-W Equipment Class ... . UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Space CFM ... Zone Sizing Data Sum of space airflow rates Individual peak space loads Number of zones Floor Area Location _. 790.0 ft2 Seattle IAP, Washington Calculation Months Jan to Dec Sizing Data _ ... Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Sub Station Zn 118.0 3470 3470 Jul 1500 12.0 790.0 4.39 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Sub Station Zn TPSS e-w 1 118.0 Jul 1500 3470 12.0 790.0 4.39 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 1096 ft2 2535 - 1096 ft2 4844 - Roof Transmission 790 ft2 2097 - 790 ft2 3492 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 120 ft2 -655 - 120 ft2 3677 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1185 W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109959 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 117978 0 - 12013 0 Zone Conditioning - 117285 0 - 11954 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 3470 CFM 0 - 3470 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 3470 CFM 0 - 3470 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 117285 0 - 11954 0 Central Cooling Coil - 117285 0 - 0 0 Central Heating Coil - 0 - - 11954 - » Total Conditioning - 117285 0 - 11954 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg Toads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Sub -Station Package E-W Project Name: ST T019 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE "TPSS a-w " IN ZONE " Sub Station Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F OCCUPIED T-STAT 90.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTUIhr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 1096 ft2 2535 - 1096 ft2 4844 - Roof Transmission 790 ft2 2097 - 790 ft2 3492 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 120 ft2 -655 - 120 ft2 3677 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ftz 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1185 W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109959 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 117978 0 - 12013 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " TPSS a-w " IN ZONE " Sub Station Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 470 0.094 - 2001 - 2077 S EXPOSURE WALL 114 0.094 - 224 - 504 DOOR 24 0.652 - -131 - 735 E EXPOSURE WALL 470 0.094 - 303 - 2077 N EXPOSURE WALL 42 0.094 - 8 - 186 DOOR 96 0.652 - -524 - 2942 H EXPOSURE ROOF 790 0.094 - 2097 - 3492 Hourly Analysis Program v4.60 Page 4 of 4 Sub -Station Package N-S Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones ,-..Substation Package N-S Undefined Single Zone CAV 1 2. System Components: Ventilation Air Data: Airflow Control ,, Constant Ventilation Airflow Ventilation Sizing Method .... Sum of Space OA Airflows Unocc, Damper Position , ,, _- Closed Damper Leak Rate ..,. 0 Outdoor Air CO2 Level 400 ppm Central Cooling Data: Supply Air Temperature ° Coil Bypass Factor 0.100 Cooling Source ._. Any Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source Any Schedule . _... -.. , ...-,..._.,._... JFMAMJJASOND Capacity Control . Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type _ Forward Curved Configuration Draw-thru Fan Performance 0.00 in wg Overall Efficiency 54 % Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Retum Air Via 3. Zone Components: Space Assignments: .0 % 0 Ducted Return Zone 1: Sub Station Zn TPSS n-s x1 Thermostats and Zone Data: Zone .-.. All Cooling T-stat: Occ. 90.0 °F Cooling T-stat: Unocc. 90.0 °F Heating T-stat: Occ, 70.0 °F Heating T-stat: Unocc, . .... 65.0 °F T-stat Throttling Range 1.50 °F Diversity Factor 100 % Direct Exhaust Airflow 0.0 CFM Direct Exhaust Fan kW . 0.0 kW Thermostat Schedule „-. Sample Schedule Unoccupied Cooling is .. Available Supply Terminals Data: Zone .., All Terminal Type Diffuser Minimum Airflow 0.00 CFM/person Zone Heating Units: Zone .. All Zone Heating Unit Type --. None Zone Unit Heat Source Any Hourly Analysis Program v4.60 Page 1 of 2 Sub -Station Package N-S Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow ........ Heating Supply Temperature Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T ... Safety Factors: Cooling Sensible Cooling Latent Heating .............. Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method JFMAMJJASOND 58.0 °F 3470.7 CFM . 0.0 CFM _ 95.0 °F 10.0 °F 20.0 °F 0 % 0 % 0 Sum of space airflow rates Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 3470.7 - - 5. Equipment Data No Equipment Data required for this system. Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 05:OOPM Air System Information Air System Name Sub -Station Package N-S Equipment Class UNDEF Air System Type ..__ ... SZCAV Sizing Calculation Information Zone and. Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM ....... .... .. Individual peak space Toads Central Cooling Coil Sizing Data Total coil load .. Total coil load Sensible coil load .. Coil CFM at Jul 1300 Max block CFM... Sum of peak zone CFM Sensible heat ratio ft2/Ton BTU/(hr-ft2) Water flow @ 10.0 °F rise Central Heating Coil Sizing Data Max coil load Coil CFM at Des Htg Max coil CFM Water flow @ 20.0 °F drop Supply Fan Sizing Data Actual max CFM Standard CFM ._..._ . Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2 ...... . ... 9.8 Tons 117.1 MBH 117.1 MBH 3471 CFM 3471 CFM 3471 CFM 1.000 80.9 148.3 23.44 gpm 10.9 MBH 3471 CFM 3471 CFM 1.09 gpm 3471 CFM 3415 CFM 4.39 CFM/ft2 0 CFM 0.00 CFM/ft2 Number of zones . Floor Area _..... Location Calculation Months Sizing Data Load occurs at OADB/WB Entering DB / WB Leaving DB / WB Coil ADP Bypass Factor ... Resulting RH Design supply temp. Zone T-stat Check Max zone temperature deviation. 1 790.0 ft2 Seattle IAP, Washington Load occurs at BTU/(hr-ft2) Ent. DB / Lvg DB Fan motor BHP Fan motor kW Fan static. CFM/person Jan to Dec Calculated Jul 1300 . 83.0 / 64.3 °F 91.8 / 53.1 °F 60.0/38.2 °F 56.5 °F 0.100 58.0 °F 0of1 OK 0.3 °F Des Htg 13.8 69.7/72.6 °F 0.00 BHP 0.00 kW .. 0.00 in wg 0.00 CFM/person Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 05:OOPM Air System Information Air System Name ...... SubStation Package N-S Equipment Class ... UNDEF Air System Type . SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Space CFM Zone Sizing Data Sum of space airflow rates _ Individual peak space loads Number of zones ... 1 Floor Area _ 790.0 ft2 Location _. Seattle IAP, Washington Calculation Months .. Sizing Data Jan to Dec Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft9) Zone CFM/ft2 Sub Station Zn 118.0 3471 3471 Jul 1300 11.2 790.0 4.39 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft') Space CFM/ft' Sub Station Zn TPSS n-s 1 118.0 Jul 1300 3471 11.2 790.0 4.39 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 05:OOPM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1300 COOLING OA DB / WB 83.0 °F / 64.3 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft' - - Wall Transmission 1240 ft' 1905 - 1240 ft' 5481 - Roof Transmission 790 ft' 2579 790 ft' 3492 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 72 ft' -468 - 72 ft' 2206 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 1185 W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109958 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 118015 0 - 11179 0 Zone Conditioning - 117149 0 - 10920 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 3471 CFM 0 - 3471 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 3471 CFM 0 - 3471 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 117149 0 - 10920 0 Central Cooling Coil - 117149 0 - 0 0 Central Heating Coil - 0 - - 10920 - » Total Conditioning - 117149 0 - 10920 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg Toads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 05:OOPM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " TPSS n-s " IN ZONE " Sub Station Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1300 COOLING OA DB / WB 83.0 °F / 64.3 °F OCCUPIED T-STAT 90.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft' - - Wall Transmission 1240 ft' 1905 - 1240 ft' 5481 - Roof Transmission 790 ft' 2579 - 790 ft' 3492 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 72 ft' -468 - 72 ft' 2206 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 1185W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109958 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 118015 0 - 11179 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " TPSS n-s " IN ZONE " Sub Station Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft') (BTU/(hr-ft'-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 114 0.094 - 218 - 504 DOOR 24 0.652 - -156 - 735 S EXPOSURE WALL 518 0.094 - 1551 - 2290 E EXPOSURE WALL 90 0.094 - 58 - 398 DOOR 48 0.652 - -312 - 1471 N EXPOSURE WALL 518 0.094 - 78 - 2290 H EXPOSURE ROOF 790 0.094 - 2579 - 3492 Hourly Analysis Program v4.60 Page 4 of 4 POST BASE ASSEMBLY FINISHED GRADE 1/8 CONCRETE FOOTING - COMMERCIAL CONCRETE PIPE DRAIN - 3/4" ID. T"LONG GRANULAR, FREE DRAINING MATERIAL COVER PLATE SEAL WELD SECTION OA DIRECTION OF PEDESTRIAN/ BICYCLE TRAFFIC 1'-2 IR' DIAM. ROUND FOOTING 1/8 1/8 1/8 1/0' • 1 7/8' SQUARE PLATE 4 3/4' 01AM. 1/8" PLATE -s 3 13/16' DIAM. TOP PLATE POST SLEEVE BASE PLATE POST SLEEVE CAP PLAN VIEW 1l4" CHAIN - GRADE 3. 8" LONG Q BASE ASSEMBLY STEEL PIPE -ASTM A 53, NPS 4 (4' NOM.). SCHEDULE 413 - WELD TO TOP PLATE 5/6" PLATE I/O" CHAMFER (rm.) DIRECTION OF PEDESTRIAN/ BICYCLE TRAFFIC SQUARE FOOTING PAINT ASSEMBLY WITH A "HIGHLY VISIBLE- COLOR. (SAFETY YELLOW IS ACCEPTABLE) 3/4" DIAM. DRAIN HOLE BASE PLATE 1/8" • 1 7/8' SQUARE PLATE 1 1/4" • T, FULL SURFACE, HEAVY DUTY, WELO-0N HINGE Ir • 4 12' OIAM. STEEL PLATE I/O CAP AND HINGE STEEL CAP PLATE 1/8 VT REFLECTIVE TAPE (TYP.) STEEL PIPE - ASTM A 53, NPS 3 (3" NOM.), SCHEDULE 80 /2" REFLECTIVE TAPE (TYPJ /6 1/4" . 1 1/2" • 2" STEEL PLATE WITH ROUNDED CORNERS AND 314 CENTERED HOLE POST NOTE This belled does not have an effective breakaway design feature and cannot be installed within the Design Clear Zone. EXPIRES JUNE 19, 2010 1 BOLLARD TYPE 1 STANDARD PLAN H-60.10-0' SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Paseo Bakotich III 07-03-08 Wedbiyron Rats D.Pwmnm A Tnneporlalienn DRAWN BY: BILL BERENS FINISHED GRADE CONCRETE FOOTING - COMMERCIAL CONCRETE 6" + 1/4" OIAM. STEEL BAR POST SECTION AO ROUND FOOTING PLAN VIEW STEEL CAP PLATE re 12" REFLECTIVE TAPE (TYP.) STEEL PIPE - ASTM A 53, NPS 3 (3" NOM.). SCHEDULE BO 12' REFLECTIVE TAPE (TYP.) FRONT VIEW 610E VIEW PAINT ASSEMBLY WITH A "HIGHLY VISIBLE" COLOR, (SAFETY YELLOW IS ACCEPTABLE) POST 1. - 2112 SQUARE FOOTING J NOTE This bollard does not have an effective breakaway design feature and cannot be Installed within the Design Clear Zone. 5/16' DRILLED HOLE 1 EXPIRES JUNE 19, 2010 BOLLARD TYPE 2 STANDARD PLAN H-60.20.01 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Paseo Bakotich 111 0743-08 EWE 061401 MINE. omr Washington WI Ilagannorni of Trewrgalion City of Tukwila Department of Community Development 10/3/2016 NICOLE SIEBEL 401 S JACKSON ST SEATTLE, WA 98104 RE: Permit No. M15-0080 SOUND TRANSIT 4524 134TH PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/25/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/25/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0080 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director May 17, 2016 Nicole Siebel Sound Transit 401 S Jackson St Seattle, WA 98104 RE: Request for Extension #1 Permit Number M15-0080 Dear Ms. Siebel, This letter is in response to your written request for an extension to Permit M15-0080. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 25, 2016. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, -)e‘4 Bill Rambo Permit Technician File: Permit No. M15-0080 W:\Permit Center\Extension Letters\Perntits\2015\M15-0080 Permit Extension #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 MEMO 1111 $OUNDTRANSIT May 12, 2016 TO: Bill Rambo FROM: Nicole Siebel SUBJECT: Request for Extension Electrical Permit No. M 15-0080 Dear Mr. Rambo Sound Transit respectfully requests an extension of the existing Mechanical Permit # M 15-0080 for installation of air conditioning in our Traction Powered Substation. This work has been put on hold while we await award of this project to a contractor. This extension will reduce project start up times to allow the contractor to begin work as soon as they are granted Notice to Proceed. Should you have any questions, please do not hesitate to contact me. My office number is 206 370-5693 and my email is nicole.siebel@soundtransit.org. Best Regards, S, Q/Le) Nicole Siebel Project Coordinator - Permits Request for Extensionr�# / Current Expiration Date: l0- 2-1/45-, f 1� Extension Request: [P Approved for it- d days Denied (provide explanation) I Signature/Initials RECEIVED CITY OF TUKWILA MAY 13 201b PERMIT CENTER City of Tukwila Department of Community Development 5/3/2016 NICOLE SIEBEL 401 S JACKSON ST SEATTLE, WA 98104 RE: Permit No. M15-0080 SOUND TRANSIT 4524 134TH PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/25/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/25/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0080 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development November 4, 2015 NICOLE SIEBEL 401 S JACKSON ST SEATTLE, WA 98104 RE: Application No. M15-0080 SOUND TRANSIT 4524 S 134TH PL Dear NICOLE SIEBEL: Jim Haggerton, Mayor Jack Pace, Director Permit application M15-0080 for the work proposed at SOUND TRANSIT (4524 S 134TH PL) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 12/29/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0080 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0080 PROJECT NAME: SOUND TRANSIT DATE: 06/29/15 SITE ADDRESS: 4524134TH PL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: DWG kJ Building Division Public Works ❑ Alit km 40 Fire Prevention Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/30/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 07/28/15 El REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION M/S—00,5-I STATE OF WASHINGTON) COUNTY OF KING ) ss. COU ADO [please print name] , states as follows: PERMIT NO: /G(9 e63 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number \ I , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform constructiorcIxorlc. 11 Owrier/Owner's Agent* 1 • LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 ww Signed and sworn to before me this day of f%re/1166 , 20 7.52, ,.:Niqi,/,-(_-((,e_/.6-(_,/,- *(7iTirkY PUBLIC in and for the State of Washington Residing at `} (!!�l' , County Name as commissioned: �-�%,Ga4 7`'_A1-a'/ IC My commission expires: 0 J (?-/'/ S 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: t. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; to. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; >>. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. * Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. 0 N 0 0 0 co 0 0 0 0 z 0 0 Q 0 J Q W U z 0 z 0 0 cd n.o rncb rP N 0 d' N_ — C lf) � CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY POJECT LOCATION LOCATIO\ V AP NOT TO SCALE 0• foo,/aIa®IRH,IIII `..�. 4.�aA ,a._rmwrNi_anv♦.•■.l�rm mina `110,„ t1,\............a.t u.e...0 1.1,4 . ■..Ili w...S.' j IIII/l■ �..l--71rimr. �>tI1 m ,211 ie ,�.,N � . ��� � ' l:.1' s:'-\��>.IOII t 11 ! Tama l . .; _.r.r.. . w.� I��SI®ii� ltx rRl/ll� 111lii11l►1�� IllH 11 imii MIMI �11sa:c.1 �n�nr iliPutilib 111161101k: i I NPnur rn I itiit til CNEa N HAM EYE 10G LACE., V NGSaC W. H .Q., PROJECT Mums�a � LOCATIONS iii Vvi 1 1 MIN i ph irii I Iiii „ . „ ,, t t , ell il IV i g di nil I r! 1 t1/4 lipiii... mix las re• iherworplailakgi% man Ilea lilitil5411�11 IIil1 ■ re gym.. l .f.- ®+N.M=�. min ■l. Ii===nt,.,_,�._t�.RaI71= „�\,�� � r�rr�.awrwrR�.rr.r� 11��1���ur�ar���. 1011111 III.►� 111111 �ii!Mir L1lllIL! !1�11I1r 111111�111601 11 IpIXIIIitM1i%%i!'� 1161wElgolurirs 1'11 iiif, ��T �I� :Mil 'Jilt g mum IIIII!Aiir1111111 VICI\ TY MA SCALE: 1 " = 4000' JR vAv S -CTICAL INST VAC INSTALL CONTRACT CN 0056-15 36 100% IFB DRAWINGS MAY 8, 2015 REVISIONS No changes shall be made to the SOW Of work without prior approval of Tukwila Building Division. NOTE: Revisions will ro quire a new plan submittal and may irc'ude additional plan review f2Cs. cc Permit No. M - Wt60 PREPARED BY: KPFF CONSULTING ENGINEERS SUBMITTED BY: City of Tukwila BUILDING DIVISION DATE: SARA L. ROBERTS, S..E PRINCIPAL DESIGNER KPFF CONSULTING ENGINEERS REVIEWED BY: BRYON AGAN, P.E. CIVIL ENGINEERING SUPERVISOR tw! REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 •10 City of Tukwila UILDING DIVISION RECEi.VED CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER DRAWING No. SM0036-GZO1 LOCATION ID: SHEET No. 1 REV: 0 SHT NO. DWG NO. REV TITLE INDEX OF DRAWINGS PROJECT INFORMATION GENERAL 1 SM0036-GZO1 0 COVER SHEET 2 SM0036-GZO2 0 DRAWING INDEX, PROJECT INFORMATION, PROJECT TEAM 3 SM0036-GZO3 0 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS, GENERAL DETAILS CIVIL 4 SM0036-CP01 0 HVAC EQUIPMENT LAYOUT - ROYAL BROUGHAM 5 SM0036-CP02 0 HVAC EQUIPMENT LAYOUT - STADIUM 6 SM0036-CP03 0 HVAC EQUIPMENT LAYOUT - SOUTH HOLGATE 7 SM0036-CP04 0 HVAC EQUIPMENT LAYOUT - SOUTH LANDER 0 0 0 M 0 0 �o M O O z 0 g 0 0 2 Q U O U 0) CO 0 J cci w 2 a.• 0 o N `- e- o 8 9 SM0036-CP05 SM0036-CP06 0 0 HVAC EQUIPMENT LAYOUT - YARD NORTH HVAC EQUIPMENT LAYOUT - YARD SOUTH 10 SM0036-CP07 0 HVAC EQUIPMENT LAYOUT - BOEING 11 SM0036-CP08 0 HVAC EQUIPMENT LAYOUT - SOUTH 133RD 12 SM0036-CP09 0 HVAC EQUIPMENT LAYOUT - TUKWILA 13 SM0036-CP10 0 HVAC EQUIPMENT LAYOUT - AIRPORT 14 SM0036-TTO1 0 TRAFFIC CONTROL PLAN ROYAL BROUGHAM 15 SM0036-TTO2 0 TRAFFIC CONTROL PLAN STADIUM 16 SM0036-TTO3 0 TRAFFIC CONTROL PLAN SOUTH HOLGATE 17 SM0036-TTO3 0 TRAFFIC CONTROL PLAN SOUTH LANDER ARCHITECTURAL 18 SM0036-ADO1 0 ARCHITECTURAL DETAILS MECHANICAL 19 SM0036-MZ01 0 MECHANICAL LEGEND AND ABBREVIATIONS 20 SM0036-MZ02 0 GENERAL NOTES AND ENERGY CODE 21 SM0036-MZ03 0 EQUIPMENT SCHEDULES, CONTROL SEQUENCE AND DIAGRAM 22 SM0036-MH01 0 SIGNAL HOUSE EQUIPMENT PLAN - ROYAL BROUGHAM 23 SM0036-MH02 0 SIGNAL HOUSE EQUIPMENT PLAN - STADIUM 24 SM0036-MH03 0 SIGNAL HOUSE EQUIPMENT PLAN - SOUTH HOLGATE 25 SM0036-MH04 0 SIGNAL HOUSE EQUIPMENT PLAN - SOUTH LANDER 26 SM0036-MH05 0 SIGNAL HOUSE EQUIPMENT PLAN - YARD NORTH 27 SM0036-MH06 0 SIGNAL HOUSE EQUIPMENT PLAN - YARD SOUTH 28 SM0036-MH07 0 SIGNAL HOUSE EQUIPMENT PLAN - BOEING. 29 SM0036-MH08 0 SIGNAL HOUSE EQUIPMENT PLAN - SOUTH 133RD 30 SM0036-MH09 0 SIGNAL HOUSE EQUIPMENT PLAN - TUKWILA 31 SM0036-MH 10 0 SIGNAL HOUSE EQUIPMENT PLAN - AIRPORT ELECTRICAL 32 SM0036-EZ01 0 LEGEND AND ABBREVIATIONS 33 SM0036-EPO1 0 ELECTRICAL PLAN - ROYAL BROUGHAM 34 SM0036-EPO2 0 ELECTRICAL PLAN - STADIUM 35 SM0036-EPO3 0 ELECTRICAL PLAN - SOUTH HOLGATE 36 SM0036-EPO4 0 ELECTRICAL PLAN - SOUTH LANDER 37 SM0036-EPO5 0 ELECTRICAL PLAN - YARD NORTH 38 SM0036-EPO6 0 ELECTRICAL PLAN - YARD SOUTH 39 SM0036-EPO7 0 ELECTRICAL PLAN - BOEING 40 SM0036-EPO8 0 ELECTRICAL PLAN - SOUTH 133RD 41 SM0036-EPO9 0 ELECTRICAL PLAN - TUKWILA 42 SM0036-EP10 0 ELECTRICAL PLAN - AIRPORT 43 SM0036-ED01 0 ELECTRICAL PANEL SCHEDULE - ROYAL BROUGHAM 44 SM0036-ED02 0 ELECTRICAL PANEL SCHEDULE - STADIUM 45 SM0036-ED03 0 ELECTRICAL PANEL SCHEDULE - SOUTH HOLGATE 46 SM0036-ED04 0 ELECTRICAL PANEL SCHEDULE - SOUTH LANDER 47 SM0036-ED05 0 ELECTRICAL PANEL SCHEDULE - YARD NORTH 48 SM0036-ED06 0 ELECTRICAL PANEL SCHEDULE - YARD SOUTH 49 SM0036-ED07 0 ELECTRICAL PANEL SCHEDULE - BOEING 50 SM0036-ED08 0 ELECTRICAL PANEL SCHEDULE - SOUTH 133RD 51 SM0036-ED09 0 ELECTRICAL PANEL SCHEDULE - TUKWILA 52 SM0036-ED10 0 ELECTRICAL PANEL SCHEDULE - AIRPORT DESCRIPTION OF WORK: THIS PROJECT INCLUDES INSTALLATION OF AIR CONDITIONING EQUIPMENT AT SOUND TRANSIT SIGNAL INSTRUMENT HOUSE FACILITIES ASSOCIATED WITH CENTRAL AND SOUTH CORRIDOR LINK LIGHT RAIL. ASSOCIATED WORK INCLUDES BUT IS NOT LIMITED TO SPLIT SYSTEM AIR CONDITIONING UNITS, CONCRETE EQUIPMENT PADS, WIRING, CONDUIT, REFRIGERANT PIPING, ELECTRICAL AND MECHANICAL ACCESSORIES, AND COMMISSIONING. PROJECT LOCATIONS: (ADDRESSES ARE APPROXIMATE) ROYAL BROUGHAM: ROYAL BROUGHAM & SODO BUSWAY SEATTLE WA 98134 STADIUM: ROYAL BROUGHAM LIGHT RAIL STATION SEATTLE WA 98134 SOUTH HOLGATE: S. HOLGATE & SODO BUSWAY SEATTLE WA 98134 SOUTH LANDER: S. LANDER & SODO BUSWAY SEATTLE WA 98134 YARD NORTH & SOUTH: ST OPERATIONS & MAINTENANCE FACILITY 3704 AIRPORT WAYS SEATTLE WA 98134 BOEING: 11037 E MARGINAL WAY S TUKWILA WA 98168 SOUTH 133RD STREET: 4562 S 133 RD TUKWILA WA 98168 TUKWILA: TUKWILA INT BOULEVARD STATION 15426 SOUTH CENTER BOULEVARD TUKWILA WA 98188 C37 AIRPORT: 17151 PACIFIC HIGHWAY S. SEATTLE WA 98158 PROJECT TEAM CLIENT: SOUND TRANSIT UNION STATION 401 JACKSON STREET SEATTLE, WA 98104 CONTACT: BARRY ALAVI 206.398.5433 STRUCTURAL ENGINEER: KPFF CONSULTING ENGINEEERS 1601 5TH AVE, SUITE 1600 SEATTLE, WA 98101 CONTACT: SARA ROBERTS 206.622.5822 206.622.8130 (FAX) PRIME CONSULTANT: KPFF CONSULTING ENGINEERS 1601 5TH AVE, SUITE 1600 SEATTLE, WA 98101 CONTACT: SARA ROBERTS 206.622.5822 206.622.8130 (FAX) ARCHITECT: TISCARENO ASSOCIATES 500 UNION ST SUITE 926 SEATTLE, WA 98101 CONTACT: CHARLES WRIGHT 206.325.3356 206.701.9769 (FAX) (5" MECHANICAL ENGINEER: CDI ENGINEERS 19203 36TH AVE W. BLDG.4 SUITE 200 ' LYNNWOOD WA 98.36 CONTACT: JON DELLA 425.672.1071 425.778.8769 (FAX) ELECTRICAL ENGINEER:• ELCON ASSOCIATES 16300 CHRISTENSEN ROAD SUITE 3.30. SEATTLE,WA 98188 CONTACT: HAROLD SMYTH 206.243.5022 206.243.5205 (FAX) REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila . BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER DESIGNED BY: D. TIMPSON DRAWN BY: W. MAIPID CHECKED BY: T. BRUCE No. DATE DSN CHK APP REVISION APPROVED BY: S.ROBERTS Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED BY: D. TIMPSON DATE: 5/8/15 REVIEWED BY: B. ALAVI LINE IS 1" AT FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036_GZ02.dwg CONTRACT No.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES DRAWING No.: NON -CRITICAL HOUSES SM0036-GZO2 DRAWING INDEX PROJECT INFORMATION PROJECT TEAM LOCATION ID: SHEET No.: REV: 02 0 GENERAL NOTES DESCRIPTION LINETYPES ABBREVIATIONS 1. LOCATIONS SHOWN FOR EXISTING UTILITIES ARE APPROXIMATE. FIELD -LOCATE EXISTING UTILITIES TO DETERMINE EXTENT OF PROTECTION NEEDED AND/OR CHANGES THAT MAY BE REQUIRED. USE CARE WHEN EXCAVATING NEAR EXISTING UTILITIES. 2. UTILITY LOCATES: CALL MINIMUM 2 AND MAXIMUM 10 BUSINESS DAYS BEFORE YOU DIG. 1 (800) 424-5555. 3. MAINTAIN SEWER MAINTENANCE HOLES, WATER VALVES AND METERS, FIRE HYDRANTS, AND UTILITY VAULTS ACCESSIBLE AND CLEAR OF BLOCKAGE BY CONTRACTOR EQUIPMENT, MATERIALS, OR DEBRIS. 4. ALL DRAWINGS ARE SCHEMATIC AND ARE NOT TO SCALE. GC SHALL FIELD VERIFY ALL DIMENSIONS AND AS -BUILT CONDITIONS. 5. DASHED LINES AT NEW HVAC UNITS INDICATE MANUFACTURER'S RECOMMENDED CLEARANCES FOR AIR INTAKE/EXHAUST, INSTALLATION, MAINTENANCE/SERVICE ACCESS, AND ECONOMIZER AND HOOD PER SPECIFICATIONS. 6. PROPOSED UNIT LOCATIONS, UTILITY CONDUIT ROUTING AND ALL ASSOCIATED CLEARANCES SHALL BE REVIEWED AND VERIFIED IN THE FIELD BY GC AT EACH LOCATION IN COORDINATION WITH ST RE. 7. DUCTWORK, CONDUIT & PIPING SUPPORT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL MEET APPLICABLE CODES AND STANDARDS FOR SUPPORT AND RESTRAINT OF ALL NEW AND RELOCATED DUCTWORK, CONDUIT AND PIPING. 8. ALL SERVICE INTERRUPTIONS AND DISCONNECTIONS SHALL BE SCHEDULED IN ADVANCE WITH ST RE. WHERE REQUIRED, DISCONNECTION AND RELOCATION/RECONNECTION OF NET WORK CONTROLLER BOX TO BE COORDINATED WITH ST RE. DISCONNECTION AND RELOCATION/RECONNECTION OF ANY SIGNAL EQUIPMENT SHALL BE COORDINATED BY THE CONTRACTOR WITH KCM OPERATIONS FOR REVIEW, APPROVAL AND ADVANCE SCHEDULING. 9. MOUNTING DETAILS FOR NEW EQUIPMENT TO WALLS OR EQUIPMENT PADS ARE CONTRACTORS RESPONSIBILITY OR PER MANUFACTURER'S INSTRUCTIONS UNO. 10. NEW CONDUIT AND WIRE ROUTING, AND RELOCATION OF EXISTING CONDUIT, WIRING AND EQUIPMENT TO ACCOMMODATE NEW INSTALLATION WILL BE BY CONTRACTOR WITH FIELD VERIFICATION OF EXISTING SPACE LIMITATIONS. EXISTING RIGHT-OF-WAY LINE EXISTING PROPERTY/LOT LINE SECTION LINE CENTERLINE CHAIN LINK FENCE EQUIPMENT CLEARANCES CONTRACTOR WORKING LIMITS MATCH LINE < > DESCRIPTION HATCH PATTERNS ALL HATCH PATTERN ORIENTATION IS BASED OFF NORTH CONCRETE AGGREGATE BASE COURSE EXISTING STRUCTURE TO BE REMOVED 0 0 cd N 0 r,o cn O O ro M O O z 0 a w O 2 cn J U U cn Q " cn o J O wCO - 2 I - a. 'o N Lc) - 70 0 o GENERAL SYMBOLS TYPICAL EQUIPMENT PAD NTS NORTH ARROW NOTES: 1. ALL NOTES SHALL USE THIS FORMAT AND SHOULD BE LOCATED AT TOP RIGHT OF SHEET. DETAIL, ELEVATION OR SECTION SCALE: DRAWING NUMBER OF SHEET WHERE THIS IS SHOWN 1 XX DETAIL, ELEVATION OR SECTION X SCALE: DASH FOR REFERENCE ON THE SAME SHEET ONLY DESIGNATION (LETTER) DRAWING NUMBER OF SHEET WHERE THIS IS SHOWN (DASH IF ON SAME SHEET ONLY) DESIGNATION (NUMBER FOR DETAIL) (LETTER FOR ELEVATION OR SECTION) DRAWING NUMBER OF SHEET INDICATING WHERE THIS IS REFERENCED DESIGNATION (NUMBER FOR DETAIL) (LETTER FOR ELEVATION OR SECTION) DRAWING NUMBER OF SHEET WHERE THIS IS SHOWN (DASH IF ON SAME SHEET ONLY) DESIGNATION (NUMBER) COORD. TOP ELEVATION IN FIELD W/ ST RE FOR DRAINAGE REQUIREMENTS. #4 @ 12 EACH WAY, MID DEPTH MIN 5" AT SH CONDENSER OR PER HVAC MANUFACTURER'S RECOMMENDATIONS. NOTES: 1. CONCRETE WORK SHALL CONFORM TO CHAPTER 19 OF IBC CONCRETE MIX SHALL BE 3,000 psi fc AT 28 DAY TEST. WATER/CEMENT RATIO SHALL BE 0.45 MEASURED BY WEIGHT AIR ENTRAINMENT SHALL BE BETWEEN 4.5 AND 7.5% REQUIREMENTS. REINFORCING STEEL SHALL BE ASTM A 615 GRADE 60 DEFORMED BARS. DIMENSIONS OF EQUIPMENT PADS SHALL BE: 2. - 30 X 46 INCHES AT SPLIT SYSTEM EXTERIOR UNIT - DIMENSION OF EQUIPMENT PLUS SIX INCHES ALL SIDES AT PACKAGE UNITS - OR PER MANUFACTURES INSTALLATION REQUIREMENTS, WHICHEVER IS GREATER. PAD SHALL BE POURED MONOLITHICALLY AND SHALL BE 3. FLUSH WHERE ADJACENT TO AN EXISTING CONCRETE PAD. PREPARE SUB GRADE BY REMOVING ALL DEBRIS AND ANY 4. SOFT OR ORGANIC MATERIAL. GRADE SHALL BE EVEN & LEVEL PRIOR TO CONCRETE PLACEMENT. DESIGNED BY: D. TIMPSON DRAWN BY: W. MAIPID CHECKED BY: T. BRUCE No. DATE DSN CHK APP REVISION APPROVED BY: S.ROBERTS Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED BY: D. TIMPSON DATE: 05/8/15 REVIEWED BY: B. ALAVI w Z 7.1 FULL SCALE SOUNDTRANSIT DATE: 05/8/15 ABD ABV ADDL AHD ALT APPROX ARCH ASPH AVE AVG BK BEG B/H BLD,BLDG BLVD BLW BMS BOT BTWN CB CCTV CDF CIP CTR CONC CONST COORD CONT COS CP DEPT DF DIA,0 DIM DIST DTL DWG E EA EG EL ELEC ELEV EOP EQN EQ EQUIP EXIST FA FF FH FG FO FRWY FS FT FUT G GPS GV GVL HORIZ HT HWY IBC IE INV IRG JOC KC(M) LF LG LLRT LT SCALE: NO SCALE AT ABANDON, ABANDONED ABOVE ADDITIONAL AHEAD ALTERNATE AND APPROXIMATELY ARCHITECT, ARCHITECTURE ASPHALT AVENUE AVERAGE BACK BEGIN BULKHEAD BUILDING BOULEVARD BELOW BUILDING MANAGEMENT SYSTEM BOTTOM BETWEEN CATCH BASIN CLOSED CIRCUIT TELEVISION CONTROLLED DENSITY FILL CAST -IN -PLACE CENTERLINE CENTER CONCRETE CONSTRUCTION COORDINATE CONTINUED CITY OF SEATTLE CROSS PASSAGE DEPARTMENT DIRECT FIXATION DIAMETER DIMENSION DISTANCE DETAIL DRAWING EAST EACH EXISTING GRADE ELEVATION ELECTRIC, ELECTRICAL ELEVATOR EDGE OF PAVEMENT EQUATION EQUAL EQUIPMENT EXISTING FIRE ALARM FINISH FLOOR FIRE HYDRANT FINISH GRADE FIBER OPTIC FREEWAY FLOATING SLAB FOOT, FEET FUTURE GAS GLOBAL POSITIONING SYSTEM GAS VALVE GRAVEL HORIZONTAL HEIGHT HIGHWAY INTERNATIONAL BUILDING CODE INVERT ELEVATION INVERT IRRIGATION JOB ORDER CONTRACTOR KING COUNTY (METRO) LINEAR FEET LENGTH LINK LIGHT RAIL TRANSIT LEFT glow MAX MAXIMUM MECH MECHANICAL MH MAINTENANCE HOLE MIC(S) MONUMENT IN CASE(S) MIN MINIMUM MISC MISCELLANEOUS MON(S) MONUMENT(S) N NORTH NB NORTH BOUND NE NORTHEAST NIC NOT IN CONTRACT No, # NUMBER NTP NOTICE TO PROCEED NTS NOT TO SCALE NW NORTHWEST OFCI OWNER FURNISHED CONTRACTOR INSTALLED PERP PC PCC PROP R PVMT RCD REQD REV RIM RO ROW,R/W RT S SB SCL SCH SE SEM SF SHT SPEC SPU ST ST RE STA STD STL STRUCT SW TBD TBM TEMP THK THRU T/LR TPSS TRK TYP UG UNO US UTIL VERT VIF W W/ W/O WP WSDOT WY PERPENDICULAR PRECAST POINT OF COMPOUND CURVATURE PROPOSED PROPERTY LINE PAVEMENT RECORD REQUIRED REVERSIBLE RIM ELEVATION ROUGH OPENING RIGHT-OF-WAY RIGHT SOUTH SOUTH BOUND SEATTLE CITY LIGHT SCHEDULE SOUTHEAST SEQUENTIAL EXCAVATION METHOD SQUARE FEET SHEET SPECIFICATION SEATTLE PUBLIC UTILITIES STREET SOUND TRANSIT RESIDENT ENGINEER STATION STANDARD STEEL STRUCTURE SOUTHWEST TO BE DETERMINED TUNNEL BORING MACHINE TEMPORARY THICK THROUGH TOP LOW RAIL TRACTION POWER SUB STATION TRACK TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE UNITED STATES UTILITY VERTICAL VERIFY IN FIELD WEST, WATER WITH WITHOUT WORKPOINT WASHINGTON Sty OF TRANSPOR TIO WAY VREVIEWED FOR VED JUL 01 2015 X-ING CROSSING X-OVER CROSSOVER City of Tukwila X-SECT CROSS SECTIO BUILDING DIVISION RECE:!ED CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER FILENAME: SM0036_GZ03.dwg CONTRACT No.: CN 0056-15 DATE: 05/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES GENERAL NOTES, ABBREVIATIONS AND SYMBOLS, GENERAL DETAILS DRAWING No.: SM0036-GZO3 LOCATION ID: SHEET No.: REV: 03 0 0 0) O a 0 co Cr) O O V1 O co Z O co O w U O U � u) 0 co cd a • co 0 o �mmuw�va�.+D:ncvun�s.,..4xcaw��n�.^.mr'9.a�uxc�:rt. NEW EVAPORATOR C36-ACU-01 HVAC EQUIPMENT LAYOUT: TUKWILA SCALE: 3/4"=1'-0" NOTES: 1. SEE GENERAL NOTES SHEET SM-0037-GZ03. 2. CONTRACTOR TO FIELD VERIFY LOCATION TO ALLOW FULL DOOR SWING. 3. LOCATE EXTERIOR UNIT & PAD TO MAINTAIN CLEARANCE & ACCESS AT SIDE OF INSTRUMENT HOUSE. 4. CONTRACTOR TO COORDINATE UNIT LOCATION WITH EXISTING DOWNSPOUT. CONTRACTOR SHALL PROPOSE METHOD OF SPLASH PROTECTION. 5. DASHED LINE INDICATES MANUFACTURER'S RECOMMENDED CLEARANCES FOR INTAKE EXHAUST OR INSTALLATION/MAINTENANCE ACCESS. NEW CONDENSER NOTE 5 NEW EQUIPMENT MOUNTING PAD PER GZ03, TYP EXISTING CONCRETE CURB AND METAL SCREEN WALL 1. City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 RECEI-VED CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER i DESIGNED BY: D. TIMPSON DRAWN BY: W. MAIPID CHECKED BY: T. BRUCE No. DATE DSN CHK APP REVISION APPROVED BY: S.ROBERTS Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED BY: D. TIMPSON DATE: 5/8/15 REVIEWED BY: B. ALAVI w z FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036_CP09.dwg CONTRACT No.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES HVAC EQUIPMENT LAYOUT TUKWILA DRAWING No.: SM0036-CP09 LOCATION ID: SHEET No.: REV: 12 0 0 0 al a 0 w 1— w co 5 0 O U LI O 2 U n O o0 a o I:: INTERIOR FIRE BARRIER SEAL 1 EX. GALVANIZED STEEL EXTERIOR STRUCTURE EX. RIGID INSULATION NEW CONDUIT FOR ELECTRICAL - SEE ELECTRICAL DRAWINGS EXTERIOR T. SEALANT EX. PLYWOOD WITH FIRE -RATED LAMINATE TYPICAL WALL PENETRATION - ELECTRICAL CONDUIT SCALE: 3" = 1'-0" INTERIOR FIRE BARRIER SEAL NOTES: 1. SEE NOTES ON DETAIL 1 FOR NOTES IN COMMON 2. DX LINES MUST NOT CONTACT WALL INSULATED DX LINE PER MECHANICAL DRAWINGS EXTERIOR SEALANT 1/4" FIBERGLASS INSULATION TYPICAL WALL PENETRATION - DX LINE (2 SCALE: 3" = 1'-0" NOTES: 1. CONTRACTOR TO TOUCH-UP PAINT AT AREAS OF NEW WELDING WORK. 2. PAINT TO MATCH EXISTING. Vies REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER DESIGNED BY: K.KARCKHECK DRAWN BY: R.TRAN CHECKED BY: D. NELSON No. DATE DSN CHK APP REVISION APPROVED BY: B. TISCARENO Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 1 1SCARENO ASSOCIATES ARCHITECTURE+URBAN DESIGN co w z J FULL SCALE SOUNDTRANSIT SCALE: 3"= 1'-0" FILENAME: SM0036_ADO1 CONTRACT No.: CN 0056-15 SUBMITTED BY: D. TIMPSON DATE: 5/8/15 REVIEWED BY: B.ALAVI DATE: 5/8/15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES ARCHITECTURAL DETAILS DRAWING No.: SM0036-AD01 LOCATION ID: SHEET No.: 18 REV: 0 A • B • • • • • • H MECHANICAL LEGEND CAD User: cschifferl. GENERAL SYMBOL 0 • EF-1 O SECTION SCALE: DETAIL DESCRIPTION HEAVY LINE INDICATES NEW WORK LIGHT LINE INDICATES EXISTING WORK OR BACKGROUND CENTERLINE KEY NOTE CALLOUT REVISION CALLOUT POINT OF CONNECTION EQUIPMENT CALLOUT, SEE SCHEDULE INDICATES DIAMETER OR ROUND SECTION DESIGNATION (LETTER) X XX THE SECTION IS SHOWN XX� X SCALE: DETAIL SCALE: � 1 DRAWING NUMBER OF SHEET WHERE DRAWING NUMBER OF SHEET WHERE THE SECTION IS CUT SECTION DESIGNATION (LETTER) SECTION CUT ON THE SAME SHEET ONLY SECTION DESIGNATION (LETTER) DRAWING NUMBER OF SHEET WHERE THE SECTION IS SHOWN (DASH IF ON THE SAME SHEET ONLY) DETAIL DESIGNATION (NUMBER) XX THE DETAIL IS SHOWN XX� DUCTWORK TRANSITIONS DUCT BRANCH TAKE -OFFS: d 45° No DATE DSN CHK DRAWING NUMBER OF SHEET WHERE DRAWING NUMBER OF SHEET INDICATING WHERE THE DETAIL IS REFERENCED DETAIL DESIGNATION (NUMBER) DETAIL REFERENCED ON THE SAME SHEET ONLY DETAIL DESIGNATION (NUMBER) XX ��— DRAWING NUMBER OF SHEET WHERE THE DETAIL IS SHOWN (DASH IF ON SAME SHEET ONLY) h= 1 /4"w OR h= 6"MINIMUM h= 1 /4"d OR h= 6"MINIMUM APP REVISION OR 45° DUCT SIZE TRANSITIONS: 15° (TYP) ALL DUCT TRANSITIONS ANGLES SHALL NOT EXCEED 15° h= 1 /4"d OR h= 6"MINIMUM DESIGNED BY: J. DELLA APPROVED BY: M. STAVIG VENTILATION DOUBLE SINGLE 24x12+ t----t &/ i 2 = +f+ z r EQUIPMENT SYMBOL ----- O DESCRIPTION DUCT: 1ST SIZE (IN) INDICATES SIDE SHOWN, 2ND SIZE (IN) INDICATES SIDE NOT SHOWN, INSIDE FREE AREA SUPPLY AIR DUCT - TURNING UP OR TOWARD SUPPLY AIR DUCT - TURNING DOWN OR AWAY RETURN OR EXHAUST AIR DUCT - TURNING UP OR TOWARD RETURN OR EXHAUST AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING DOWN OR AWAY TRANSITION TRANSITION ROUND TO RECTANGULAR TURNING VANES IN RECTANGULAR DUCT TURN 90° ELBOW (RADIUS = 1.5 x ELBOW DIAMETER) RECTANGULAR BRANCH CONNECTION WITH 45° TAPER CONICAL BRANCH CONNECTION 45° LATERAL FITTING 45° LATERAL FITTING WITH 45° ELBOW 90° CONICAL TEE FITTING BAROMETRIC RELIEF DAMPER VOLUME DAMPER BACKDRAFT DAMPER COMBINATION FIRE/SMOKE DAMPER (PROVIDE DUCT ACCESS PANEL) INDICATES RISE OR DROP FLEXIBLE DUCTWORK FLEXIBLE CONNECTOR CEILING DIFFUSER (FOUR-WAY AIRFLOW) RETURN/EXHAUST GRILLE DESCRIPTION THERMOSTAT OR TEMPERATURE SENSOR (120V, 1 PHASE) CONTROL WIRING/TUBING (BY ELECTRICAL) MOTORIZED DAMPER AND ACTUATOR (120V, 1 PHASE) PLUMBING AND PIPING SYMBOL CD DESCRIPTION CONDENSATE DRAIN Consulting Engineers 1601 Flfth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 ABBREVIATIONS ACU AFF ARCH BDD BHP CARTRG CD CENT CFM CH CLG CONC COND CONN CONT DB DDC DIA DISCH DN EA EAT EG EF EFF ELEV ENT ESP EXIST (E) EXT F FCO FD FHR FPM FT FV GAL HP IN KW LAT LBS LF LVG MANUF MAX MBH MCA MIN MOD NC NO OFCI OSA PD POC PRESS PSI PSIG RG RH RM RPM CDs MAZZETTI 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www. MAZZETTI . com APPROVED: B. ALAVI AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ARCHITECTURAL BACKDRAFT DAMPER BRAKE HORSEPOWER CARTRIDGE CEILING DIFFUSER CENTRIFUGAL CUBIC FEET PER MINUTE CABINET HEATER CEILING CONCRETE CONDENSATE (INSULATED) CONNECTION CONTINUATION DRAIN DRY BULB DIRECT DIGITAL CONTROL DIAMETER DISCHARGE DOWN EXHAUST AIR ENTERING AIR TEMPERATURE EXHAUST GRILLE EXHAUST FAN EFFICIENCY ELEVATOR ENTERING EXTERNAL STATIC PRESSURE EXISTING EXTERNAL FAHRENHEIT FLOOR CLEANOUT FLOOR DRAIN/FIRE DAMPER FIRE HOSE REEL FEET PER MINUTE FEET FACE VELOCITY GALLONS HORSEPOWER INCHES KILOWATT LEAVING AIR TEMPERATURE POUNDS (WEIGHT) LINEAR FOOT LEAVING MANUFACTURER MAXIMUM BRITISH THERMAL UNIT PER HOUR (THOUSAND) MINIMUM CURRENT AMPACITY MINIMUM MOTOR OPERATED DAMPER OR MODEL NOISE CRITERIA NORMALLY OPEN OR NUMBER OWNER FURNISHED CONTRACTOR INSTALLED OUTSIDE AIR PRESSURE DROP POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE RETURN GRILLE RELATIVE HUMIDITY OR RELIEF HOOD ROOM REVOLUTIONS PER MINUTE SOUNDTRANSIT SCALE: NO SCALE FILENAME: SM0036 MZ01 CONTRACT NO.: CN 0056-15 DATE: DATE: 5/8/15 5/8/15 ABBREVIATIONS (CONT) SCL SP SEC SFD SG SH SO STE TEMP TG TSP TPSS TYP V VIB VEL VERT VOL VOLT W WB WSEC SEATTLE CITY LIGHT STATIC PRESSURE SEATTLE ENERGY CODE SMOKE/FIRE DAMPER SUPPLY GRILLE SIGNAL HOUSE SCREENED OPENING SOUND TRANSIT ENGINEER TEMPERATURE TRANSFER GRILLE TOTAL STATIC PRESSURE TOTAL STATIC PRESSURE TYPICAL VENT VIBRATION VELOCITY VERTICAL VOLUME VOLTAGE WASTE/WATT WET BULB WASHINGTON STATE ENERGY CODE Is DRAWING INDEX SM0036-MZ01 SM0036-MZ02 SM0036-MZ03 SM0036-MH01 SM0036-MH02 SM0036-MH03 SM0036-MH04 SM0036-MH05 SM0036-MH06 SM0036-MH07 SM0036-MH08 SM0036-MH09 SM0036-MH10 MECHANICAL LEGEND AND ABBREVIATIONS GENERAL NOTES AND ENERGY CODE MECHANICAL EQUIPMENT SCHEDULES, CONTROL SEQUENCE ANI SIGNAL HOUSE EQUIPMENT PLAN - ROYAL BROUGH SIGNAL HOUSE EQUIPMENT PLAN - STADIUM SIGNAL HOUSE EQUIPMENT PLAN - SOUTH HOLGATI SIGNAL HOUSE EQUIPMENT PLAN - SOUTH LANDER SIGNAL HOUSE EQUIPMENT PLAN - YARD NORTH SIGNAL HOUSE EQUIPMENT PLAN - YARD SOUTH SIGNAL HOUSE EQUIPMENT PLAN - BOEING REViEWED FOR DIZOBVOMPLIANCE M APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY Of T-U,KWILA SIGNAL HOUSE EQUIPMENT PLAN - SOUTH 133RD STREE JUG 2 9 2015 SIGNAL HOUSE EQUIPMENT PLAN - TUKWILA SIGNAL HOUSE EQUIPMENT PLAN - AIRPORT PERMIT CENTER HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES MECHANICAL LEGEND AND ABBREVIATIONS DRAWING NO.: SM0036-MZ01 LOCATION ID: SHEET NO.: 19 REV: 0 GENERAL NOTES 2012 WASHINGTON STATE ENERGY CODE 2012 SEATTLE ENERGY CODE 2012 SEATTLE ENERGY CODE (CONY) CAD User: cschifferl. Path: H: \2015\156-027 — ST TO 45 Non Critical ,Signal Houses\Dwg\SM0036_MZ02.dwg Plot date: May 07, 2015-03: 00: 27pm Xref Filename: I GZ_TB_SM0036 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON DRAWINGS, DIAGRAMS, AND AS DESCRIBED IN SPECIFICATIONS. 2. INSTALL ALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE OR ADJACENT WALLS. 3. THE -MECHANICAL- PLANS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO GENERAL, ARCH- ITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 4. ITEMS NOTED "TYPICAL" OR "TYP" ON ANY SHEET APPLY TO THAT PARTICULAR SHEET. 5. COORDINATE WITH SPECIFICATIONS. IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND DRAWINGS THE MORE STRINGENT SHALL APPLY. 6. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 7. COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF THIS CONTRACTOR. PROVIDE COORDINATED SHOP DRAWINGS PRIOR TO FABRICATION AND INSTALLATION. 8. VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY WORK ON AN EXISTING MECHANICAL SYSTEM. 9. COORDINATE EXACT LOCATIONS -OF -ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH OWNER PRIOR TO INSTALLATION. 10. PROVIDE ADEQUATE CLEARANCES FOR DOWNSPOUTS AND DRAINAGE OF RAINWATER WHEN LOCATING AC UNITS. COORDINATE CONCRETE PAD LOCATIONS FOR AC MOUNTING WITH STE IN FIELD. 11. ROUTE ALL DX PIPING ON WALLS OR ROOFS TO AVOID IMPACT DAMAGE FROM VEHICLES AND TO AVOID ELECTRICAL, EQUIPMENT CLEARANCES AND ACCESS REQUIREMENTS. 12. ALL SPACE THERMOSTAT WIRING AND CONDUIT BY ELECTRICAL CONTRACTOR. 13. AC UNITS AND SPLIT SYSTEM UNITS TO BE STAND ALONE CONTROLS. 14. ROUTE ALL CONDENSATE DRAINS AWAY FROM STRUCTURE AND UNIT, CONCRETE PADS APPROXIMATELY 12" MINIMUM. ALL DRAINS TO BE INSULATED, REFER TO DRAWINGS. 15. REPLACE ALL EXISTING MAKE-UP AIR AND VENT FAN, FILTERS WITH NEW FILTERS. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE C403.2.3(1)A THROUGH C403.2.3(1)D, C403.2.3(2), C403.2.3(3), C403.2.3(4), C403.2.3(5), C403.2.3.(7), C403.2.3(8), C403.2.3(9) AND C403.2.3 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK AND ALSO ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH MOTORIZED DAMPERS AS REQUIRED BY SECTION C403.2.4.4 OF THE WSEC AND SHALL COMPLY WITH THE DAMPER LEAKAGE REQUIREMENTS. COOLING SYSTEMS SHALL BE EQUIPPED WITH OPTIMUM START CONTROLS PER SECTION C403.2.4.3.3 OF THE WSEC. PROVIDE BALANCING DAMPERS, TEMPERATURE AND PRESSURE TEST CONNECTIONS AND BALANCING VALVES IN ALL AIR SUPPLY OUTLETS, BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.7 OF THE WSEC. DUCT TAPE NOT ALLOWED. DUCTWORK STATIC PRESSURE AND SEAL CLASS: SEAL CLASS SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS SEAL TRANSVERSE, JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS 7 DUCTWORK SHALL BE TESTED AS REQUIRED BY SECTION C403.2.7.3.3 OF THE WSEC. PROVIDE TEST REPORTS TO THE OWNER. 6. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 AND TABLE C403.2.8 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL. 10. INDIVIDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF THE BUILDING HAVING LESS THAN 24-HOUR OPERATION OR DIFFERENT USES SHALL BE SHUT OFF OR SET BACK DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 11. SUPPLY AIR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS REQUIRED IN SECTION C403.4.3.4 AND C403.4.5.4 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 12. ALL AIR SYSTEMS SHALL BE PROVIDED WITH A 100% CAPABLE AIR ECONOMIZER CAPABILITY AS REQUIRED BY THE SECTION C403.3.1 AND C403.4.1 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 13. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD AS REQUIRED IN SECTION C403.3.1.1.2 OF THE WSEC. 14. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER C403.2.10.3 AND SECTION C403.2.13 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 15. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C408.1.3.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. 16. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C408.1.3.2 OF THE WSEC AND AS SPECIFIED. 17. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2.1 AND C408.2.2.2 OF THE WSEC AND AS SPECIFIED. 18. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING BE SUB- MITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE WSEC. COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, TRAINING, REPORTS, ACCEPTANCE AND COMMISSIONING COMPLIANCE CHECKLIST. 19. COOLING SYSTEMS HAVE BEEN SIZED IN ACCORDANCE WITH SECTION C403.2.2 OF THE WSEC. WATER COLUMN 1/2 TO 3 INCHES ABOVE 3 INCHES 1 HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE C403.2.3(1)A THROUGH C403.2.3(1)D, C403.2.3(2), C403.2.3(3), C403.2.3(4), C403.2.3(5), C403.2.3.(7), C403.2.3(8), C403.2.3(9) AND C403.2.3 OF THE SEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 2. PROVIDE DEADBAND BETWEEN HEATING/COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION C403.2.4.2 OF THE SEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 3. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK AND ALSO ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3 OF THE SEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 4. OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH MOTORIZED DAMPERS AS REQUIRED BY SECTION C403.2.4.4 OF THE SEC AND SHALL COMPLY WITH THE DAMPER LEAKAGE REQUIREMENTS PER SECTION C402.4.5 OF THE SEC. 5. HEATING AND COOLING SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC START CONTROLS PER SECTION C403.2.4.3.3 OF THE SEC. 6. PROVIDE BALANCING DAMPERS, TEMPERATURE AND PRESSURE TEST CONNECTIONS AND BALANCING VALVES IN ALL AIR SUPPLY OUTLETS, BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2 OF THE SEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 7. ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED PER IMC, C402 LEAKAGE REQUIREMENTS AND IBC VAPOR RETARDER REQUIREMENTS AS REQUIRED BY SECTION C403.2.7.1 AND C403.2.7.3 OF THE SEC. DUCTWORK STATIC PRESSURE AND SEAL CLASS: WATER COLUMN SEAL CLASS 1/2 TO 2 INCHES SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS ABOVE 2 INCHES SEAL TRANSVERSE, JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS 8. DUCTWORK SHALL BE TESTED AS REQUIRED BY SECTION C403.2.7.3.3 OF THE SEC. PROVIDE TEST REPORTS TO THE OWNER. 9. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF THE SEC AND AS DESCRIBED IN THE PROJECT MANUAL. DUCT TYPE LOCATION R-VALUE/U-FACTOR DUCTS/SHAFTS/ PLENUMS FROM EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM (CONVEYING OUTSIDE AIR) U-0.055 (MEET AIR LEAKAGE AND BUILDING ENVELOPE VAPOR CONTROL REQUIREMENTS OF IBC) SUPPLY/RETURN/ PLENUMS UNCONDITIONED SPACES R-6 SUPPLY/RETURN/ PLENUMS OUTSIDE OF THE BUILDING R-8 SUPPLY WITH SUPPLY TEMP < 55°F OR > 105°F WITHIN CONDITIONED SPACE R-3.3 10. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 AND TABLE C403.2.8 OF THE SEC AND AS DESCRIBED IN THE PROJECT MANUAL: TEMP (°F) INSULA- TION CON- DUCTIVITY MEAN RATING TEMP (°F) PIPE DIAMETER: <1" 1"TO<1-1/2" 1-1/2"TO<4" 4"TO<8" >8" INSULATION THICKNESS: ABOVE 350 .32-.34 250 4.5 Ocp. "Iuncp. 0L0 LO d' N r 0 e- 5.0 5.0 5.0 251-350 .29-.32 200 3.0 4.5 4.5 4.5 201-250 .27-.30 150 2.5 2.5 3.0 3.0 141-200 .25-.29 125 1.5 2.0 2.0 2.0 105-140 .21-.28 100 1.0 1.5 1.5 1.5 61-104 .21-.28 75 1.0 1.5 1.5 1.5 40-60 .21-.27 75 0.5 1.0 1.0 1.0 BELOW 40 .20-.26 75 0.5 1.0 1.0 1.5 NOTE: PIPING INSULATION MEETS OR EXCEEDS SEC. 10a. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE AS REQUIRED BY SECTION C403.2.8.1 OF THE SEC AND AS DESCRIBED IN THE PROJECT MANUAL. 11. INDIVIDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF THE BUILDING HAVING LESS THAN 24-HOUR OPERATION OR DIFFERENT USES SHALL BE SHUT OFF OR SET BACK DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4 OF THE SEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 12. SUPPLY AIR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS REQUIRED IN SECTION C403.4.3.4 AND C403.4.5.4 OF THE SEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 13. ALL AIR SYSTEMS SHALL BE PROVIDED WITH A 100% CAPABLE AIR ECONOMIZER CAPABILITY AS REQUIRED BY THE SECTION C403.3.1 AND C403.4.1 OF THE SEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 14. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD AS REQUIRED IN SECTION C403.3.1.1.2 OF THE SEC. 15. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER C403.2.10.3 AND SECTION C403.2.13 OF THE SEC FOR FULL LOAD EFFICIENCIES. 16. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C408.1.3.1 OF THE SEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. 17. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C408.1.3.2 OF THE SEC AND AS SPECIFIED. 18. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2.1 AND C408.2.2.2 OF THE SEC AND AS SPECIFIED. 19. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING BE SUB- MITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE SEC. COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, TRAINING, REPORTS, ACCEPTANCE AND COMMISSIONING COMPLIANCE CHECKLIST. MI5OO9C REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila f3"...JILDING DIVISION RECEiVED CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER DESIGNED BY: J. DELLA DRAWN BY: S. WOOD CHECKED BY: M. STAVIG No. DATE DSN CHK APP REVISION APPROVED BY: M. STAVIG Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 CD' MAZZETTI 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www. MAZZ ETT I _cam APPROVED: B. ALAVI LINE IS 1" AT FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036 MZ02 CONTRACT NO.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES GENERAL NOTES AND ENERGY CODE MECHANICAL DRAWING NO.: SM0036-MZ02 LOCATION ID: SHEET NO.: 20 REV: 0 A • CAD User: cschifferl. Xref Filename: I GZ_TB_SM0036 SEQUENCE OF OPERATIONS SPLIT AIR CONDITIONING UNIT UNITS SHALL BE PROVIDED WITH REMOTE PROGRAMMABLE CONTROLS TO TURN UNIT ON AT SPACE TEMPERATURE SETPOINT OF 80°F (ADJUSTABLE). EXISTING UNIT VENTILATORS TO TURN OFF AT 75°F AND DAMPERS TO CLOSE VENT. UNITS TO TURN ON AGAIN AT 72°F (ADJUSTABLE). VENTILATION FAN AND AIR CONDITIONING UNITS TO BE INTERLOCKED TO PREVENT SIMULTANEOUS OPERATION. DX PIPING OUTDOOR CONDENSER INDOOR EVAPORATOR CONTROL WIRING BY CONTROLS CONTRACTOR SPACE TEMPERATURE SENSOR/CONTROLLER SPLIT SYSTEM UNIT CONTROL - CONTROL DIAGRAM SCALE: N.T.S. EXTERIOR VENTILATION FAN INTERLOCK WIRING BY CONTROLS CONTRACTOR SPACE TEMPERATURE SENSOR/CONTROLLER AIR CONDITIONING UNITS - SPLIT SYSTEM MARK LOCATION ACU ACU SEE PLANS SEE PLANS CAPACITY TYPE SPLIT SPLIT NOM CLG: TONS 2.0 3.0 NET CLG: MBH 24.0 34.2 SEER 17.0 14.0 REFRIGERANT R-410 R-410 CONNECTIONS SUCTION LINE: IN 5/8 5/8 LIQUID LINE: IN 3/8 3/8 DRAIN: IN 3/4 3/4 INDOOR SECTION LOCATION SEE PLANS SEE PLANS AIRFLOW: CFM (HIGH) 775 920 ESP: IN WG 0.2 0.2 MOTOR HP - - ELEC HEAT: KW - - FILTER TYPE DISPOSABLE DISPOSABLE WEIGHT: LBS 46 46 VOLT/PHASE 208/1 208/1 FLA 0.36 0.57 MCA 1.0 1.0 OUTDOOR SECTION (ACC3 AND ACC4) LOCATION SEE PLANS SEE PLANS WEIGHT: LBS 163 163 VOLT/PHASE 208/1 208/1 MCA 18.0 25.0 ELECTRICAL SCCR: AMPS 10,000 10,000 BASIS OF DESIGN MANUFACTURER MITSUBISHI MITSUBISHI MODEL (INDOOR) PKA-A24KA PKA-A36KA MODEL (OUTDOOR) PUY-A24NHA3 PUY-A36NHA3 NOTES [1, 2, 3, 4, 5, 6] [1, 2, 3, 4, 5] NOTES: 1. 2. 3. REFER TO ELECTRICAL DRAWINGS FOR DISCONNECT SWITCHES. OUTDOOR UNITS MOUNTED ON CONCRETE PADS WITH VIBRATION ISOLATION PADS. ROUTE 3/4" CONDENSATE DRAIN TO OUTDOORS, SEE PLANS. AVOID DISCHARGE NEAR OUTDOOR UNIT. CONDENSATE DRAINS TO BE INSULATED. 4. PROVIDE WITH WIRED MICROPROCESSOR 24/7 PROGRAMMABLE THERMOSTATIC CONTROLLER. LOW VOLTAGE WIRING AND CONDUIT BY ELECTRICAL CONTRACTOR. 5. MAXIMUM DX PIPING LENGTH = 165 FT. MAXIMUM DX PIPING HEIGHT = 100 FT. 6. UNITS INSTALLED IN C12, C14 AND C16 SIGNAL HOUSES ONLY. M(5OO 0 REViEWEU FOR_... CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION DESIGNED BY: J. DELLA DRAWN BY: S. WOOD CHECKED BY: M. STAVIG APPROVED BY: No DATE DSN CHK APP REVISION M. STAVIG Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 CD! MAZZETTI 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www. MAZZETTI .com APPROVED: B. ALAVI LINE IS 1" AT FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036 MZ03 CONTRACT NO.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES EQUIPMENT SCHEDULES, CONTROL SEQUENCE AND DIAGRAM RECEIVED VE0 CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER DRAWING NO.: SM0036-MZ03 LOCATION ID: SHEET NO.: 21 REV: 0 A • B • C • • CAD User: cschifferl. E co 0 N 0 CL cri co iv 0 M cri 0 i 0 ^�L 0 NEW REMOTE SENSOR THRM2 77.7,17-71 ram SIGNAL HOUSE EQUIPMENT PLAN: TUKWILA 1 SCALE: 3/4"=1'-0" SM0036-MH09 C\-D NEW EVAPORATOR C36-ACU-01 CONCRETE PAD, SEE GZO3 NOTES: INDOOR EVAPORATOR MOUNTED ON WALL. ELECTRICAL ITEMS TO BE REMOVED AND RELOCATED BY ELECTRICAL CONTRACTOR. COORDINATE EXACT LOCATION OF UNIT IN FIELD. OUTDOOR UNIT MOUNTED ON CONCRETE PAD WITH VIBRATION ISOLATION PADS. COORDINATE EXACT LOCATION IN FIELD. ROUTE CONDENSATE DRAIN THROUGH WALL TO 6" ABOVE GRADE. EXTEND AWAY FROM BUILDING 12" AND ELBOW DOWN. VENT FAN TO SHUT-OFF AT 75°F AND 0.10" WEIGHTED DOOR VENT BACKDRAFT DAMPE TO CLOSE. ACC AND ACU TO START AT 80°F AND RUN 30 MINUTES MINIMUM PRIOR TO SHUTTING DOWN. VENT FAN AND DOOR VENT TO START AND OPEN AT 72°F. REFER TO TO CONTROLS SEQUENCE AND DIAGRAM FOR FURTHER DETAIL. 4. o® 0 NEW CONDENSER C36-ACC-01 fSOO 80 ® DX SUCTION AND LIQUID LINES FROM ACC UP WALL AND INTO BUILDING. CONNECT TO ACU. SUPPORT DX LINES ON WALL PER SPECIFICATION. SUPPORT LINES ON GRADE WITH ENRICO PYRA- MID PIPE SUPPORTS AND PER MANUFACTURER'S RECOMMENDATIONS. SUPPORT PIPE WITH ENRICO PYRAMID PIPE SUPPORTS FASTENED TO ROOF AND PER MANUFACTURER'S RECOMMENDATIONS. 18"Wx30" 0.10" WEIGHTED BACKDRAFT DAMPER. MOUNT OVER EXISTING DOOR VENT. REMOVE EXISTING DOOR COVER. ENSURE FILTER REMAINS. ® DO 'I ? OPEN WITH VENTUFAN OP y` CITY OF TUKWILA PROVED JUL 01 2015 City of Tukwila BUILDING DIVISION JUN 2 9 2015 PERMIT CENTER No. DATE DSN CHK APP REVISION DESIGNED BY: J. DELLA DRAWN BY: S. WOOD CHECKED BY: M. STAVIG APPROVED BY: M. STAVIG Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 CDtv MAZZETTI 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www. MAZZ ETT I . co m APPROVED: B. ALAVI LINE IS 1" AT FULL SCALE ITN SOUNDTRANSIT DATE: 5/8/15 SCALE: 3/4"=1'-0" FILENAME: SM0036 MH09 CONTRACT NO.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES SIGNAL HOUSE EQUIPMENT PLAN TUKWILA DRAWING NO.: SM0036-MH09 LOCATION ID: SHEET NO.: 30 REV: 0