Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0092 - MOCTEZUMAS - ROOFTOP DISHWASHER EXHAUST FAN
M 0 CTFZUMAS 1150 SOUTHCENTER MALL CANCELLED 12/28/15 M1S-0092 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 Permit Number: 1150 SOUTHCENTER MALL Project Name: MOCTEZUMAS Issue Date: Permit Expires On: M15-0092 8/6/2015 2/2/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 AMANDA CRAMER 5108 D ST NW , AUBURN, WA, 98001 EMERALD AIRE INC 5108 D ST NW , AUBURN, WA, 98001- 2418 EMERAAI055BL ,,, Phone: (253) 872-5665 Phone: (253) 872-5665 Expiration Date: DESCRIPTION OF WORK: INSTALL ROOFTOP DISHWASHER EXHAUST FAN PER PLANS Valuation of Work: $5,000.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $258.96 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit nddaagree to the conditions attached to this permit. Signature: Jifi{ Print Name: 611(v2vtdOt vullY Date: V /LQt'LI5 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKfr _ A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: C (For office use only). MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Q'D.0-a101t) Site Address: I, -Y3 Stak-V C OfA ( ma.QQ Suite Number: Tenant Name: P(\bCAQ PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: , yvviy. 6PJA Cram( Address: .-0 a ‘k-\\)\ City:,esubAsNA State:\ Zip11Ceok PhonearJ�.�_a,aci J Faxa53. ��a .O.�� ' Email: es emo (Wei 42• eon Floor: New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION_' Company Name: Address: I "(Nu.)City: P, OR State: j y Zip `„ ,,. ` l a� Phone�'Sq (.9 Fax: , J gv- — --A-q` - Contr Reg No.:001 016,6 `u y3Exp Date: L /t (0t1. 1 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 131cto Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement [l Fuel Type: Electric ❑ Gas ❑ Other: v f P H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I l.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Q: Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit,,T,ype •', Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — comm/industrial • nit -Type Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boilee/Compressor.- 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEIR OR AUTHORIZED AGENT: Signature: Print Name: ik {\AaV\a CP',t Q (- Mailing Address: !l(".),5 Y" )j Date:Cao(,� Day Telephone:acj?j--{a.- 6( .0 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $258.96 M15-0092 Address: 1150 SOUTHCENTER MALL Apn: 9202470010 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5768 R000.322.900.04.00 0.00 $9.96 $258.96 Date Paid: Tuesday, July 21, 2015 Paid By: EMERALD AIR Pay Method: CHECK 2224 Printed: Tuesday, July 21, 2015 10:50 AM 1 of 1 i?SYSTEMS City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director February 3, 2016 Emerald Aire Inc Attn: Amanda Moore 5108 D St NW Auburn, WA 98001 RE: Partial Refund for Permit Number M15-0092 Dear Ms. Moore, Enclosed is a check for a partial refund in the amount of $159.36 (one hundred fifty nine dollars and thirty six cents). This refund is based on your request to cancel the permit. Sincerely, ral, fi Rachelle Ripley Permit Technician File: Permit No. M15-0092 Encl: Check No. 371436 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov TO: FROM: DATE: SUBJECT: MEMORANDUM Laurie Anderson January 11, 2016 Brenda Holt Refund for Mechanical Permit M15-0092 Please draw a check in the amount of $159.36 (one hundred fifty-nine dollars and thirty- six cents) payable to Emerald Aire Inc., Attn: Amanda Moore at 5108 D St NW, Auburn WA 98001. No work was performed and the permit is not needed. The permit has been cancelled and the applicant has requested a refund which the Building Official has granted at 80%. Please provide the refund as follows: Account Amount 000.322.100.00.00 $159.36 Total $159.36 Please forward the check to me and I will forward it on to the applicant. Thank you! Bill Rambo From: Amanda Moore <AmandaM@emeraldaire.com> Sent: Wednesday, December 23, 2015 10:32 AM To: Bill Rambo Cc: Ryan Johnson Subject: Moctezuma's Good morning Bill, Please cancel and refund permit M15-0092. Let me know if you need any further information. Thank you! Merry Christmas!!! © * WE WILL BE CLOSED DEC 24m, 25TH AND JAN 1ST. amanda Movie Office Administrator/Permit Specialist Emerald Aire, Inc. 5108 D Street NW Auburn, WA 98001 (253) 872-5665 C./ Request for Refund — Approved for full refund Approved for g- o % refund of ❑ Denied (provide explanation) Signature/Initials v1- fee(s) T fie.0 rwt@., CITY OF TUKINCIA 1DEG 28 2015 PER 4 T C£ PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0092 DATE: 07/21/15 PROJECT NAME: MOCTEZUMAS SITE ADDRESS: 1150 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works El AtA ,A)/A- Fire Prevention nu Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 07/23/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 08/20/15 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping D PW ❑ Staff Initials: 12/18/2013 EMERALD AIRE INC Page 1 of 2 Home Inicio en Ispanol Contact Search L&I A-2 Index Help ivly Secure L&I Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries EMERALD AIRE INC Owner or tradesperson Principals HAPPE, DOUGLAS A, PRESIDENT RIDGE, JOHN PATRICK, VICE PRESIDENT RICHARDS, RON, SECRETARY (End: 06/01/2000) DUPUIS-FRICKE, LINDA, PRESIDENT (End: 12/31/1999) HAPPE, DOUGLAS A, PRESIDENT (End: 12/31/1999) TREMAINE, DAVIS WRIGHT, AGENT (End: 12/31/1999) Doing business as EMERALD AIRE INC WA UBI No. 600 591 552 5108 D STREET NW AUBURN, WA 98001 253-872-5665 KING County Business type Corporation Goveming persons DOUGLAS HAPPE JOHN RIDGE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EMERAAI055BL Effective — expiration 01/13/1995— 04/01/2017 Bond THE HANOVER INSURANCE COMPANY Bond account no. 1977929 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 01/06/2011 01/01/2011 Expiration date Until Canceled Bond history Insurance American Fire & Casualty Co $1,000,000.00 Policy no. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600591552&LIC=EMERAAI055BL&SAW= 8/6/2015 V OC VAS So� C R REVISIONS _.. No changes shall be made to than scope of work without prior approval of Tukwila Building. Division. NOTE: Revisions will require a new plan submittal anti may in;;lude additional plan re"i fees GENERAL INFORMATION PROPERTY TAX NO.: 9202470010 LEGAL DESCRIPTION: WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) PLat Block: Plat Lot: PARCEL A PROJECT LOCATION: 1150 S❑UTHCENTER MALL TUKWILA WA 98188 PROJECT DESCRIPTION: DEMO EXISTING INLINE DISHWASHER EXHAUST, INSTALL ROOFTOP DISHWASHER EXHAUST FAN GENERAL MECHANICAL: STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PR❑VISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, MFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY CODES: ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES, IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE MOST STRICT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY, THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS & REQUIREMENTS OF THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD. APPLICABLE CODES: 2012 IMC W/WASHINGTON STATE AMENDMENTS. 2012 IBC W/WASHINGTON STATE AMENDMENTS. 2012 WASHINGTON STATE ENERGY CODE. 2012 IFGC GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS. VICINITY MAP: HVAC CONTRACTOR: EMERALD AIRE INC 5108 D STREET AUBURN, WA 98001 PROJECT MANAGER: CONTACT:RYAN JOHNSON V❑ICE: (253) 872-5665 FAX: (253) 872-5797 GENERAL CONTRACTOR: CONTRACTOR NAME ADDRESS CITY, STATE ZIP CONTACT VOICE: XXX. XXX, XXXX FAX: XXX. XXX. XXXX INDEX: EQUIPMENT SCHEDULES ST FAN INFORMATION — Job 2377015 WSEC & COMMISSIONING NOTES: THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER WSEC 403. 2, 4, 1. 1 ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO 100% ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING OUTDOOR AIR COOLING CAPACITY PER WSEC C403, 3, 1, 1 INSULATE REFRIGERANT PIPING PER WSEC TABLE C403,2,8 SEAL DUCTWORK PER WSEC C403, 2, 7, 3 INSULATE DUCTWORK PER WSEC C403, 2, 7, 1 AND C403, 2, 7, 2 COMMISSIONING PER WSEC C408 INCLUDING COMMISSIONING PLAN, SYSTEMS BALANCING, FUNCTIONAL TESTING, CONTROLS TESTING, OPERATION AND MAINTENANCE MANUALS, AND RECORD DRAWINGS, SHALL BE SUBMITTED TO OWNER ON PROJECT COMPLETION. FAN UNIT NO. TAG FAN UNIT MODEL # CFM ESP. RPM HP, B.H.P. 0 VOLT FLA WEIGHT (LBS.) SEINES 1 DU85HFA 1000 0.751 994 0.750 0.1920 1 115 8.8 69 9.1 FAN OPTIONS FAN UNIT NO. TAG OPTION (Qty. — Descr,) 1 1 — ECM Wiring Package for Exhaust Fans or Unternpered Supply Fans — Manual Speed Control, FAN #1 DU85HFA - EXHAUST FAN 31 7/8 30 1/2 n T7 El 14 7/8 21 23 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) - HIGH HEAT OPERATION 300°F (149°C) NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH❑UT ANY DETERI❑RATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, OPTIONS ECM WIRING PACKAGE FOR EXHAUST FANS OR UNTEMPERED SUPPLY FANS - MANUAL SPEED CONTROL, HVAC LEGEND & ABBREVIATIONS: ll't1� COMII FBI SD SFD r HP HP H TG H TR ID IN KW LAT LBS. LWT MA MAX MBH MIN MS NC N TS OA OBD OC OD PH PSI QTY R/A REF RET RH RLD RPM S/A SEER SH SOV SP TEMP UC v VAV VD VEL w w/ WB W/O WO1I Y d GRD IDENTIFIER SIDE WALL GRILL SUPPLY GRILLE THERMAFUSER RETURN AIR GRILLE EXHAUST GRILLE EXHAUST FAN EQUIPMENT TAG T-STAT CO SENSOR OCCUPANCY SENSOR L/V WIRE DUCT RUN ELBOW REDUCER SIDE TAPS 90 ELBOW W/ TURNING VANES FLEXIBLE DUCT MANUAL DAMPER FIRE DAMPER SD SMOKE DAMPER In SMOKE/FIRE DAMPER Y Td MOTORIZED DAMPER ar BACKDRAFT DAMPER PTa VARIABLE VOLUME/TEMPERATURE z DESCRIPTION CITY OF TUKWILA CORRECTION #1 RESPONSE 1 o w m 12014.10.22 PLOT DATE 7/16/2015 ❑ DESIGN DEVELOPMENT DRAWING DATE DATE DATE DATE DATE COORDINATION PERMIT 2014. 10, 22 CONSTRUCTION AS BUILT HEAT PUMP HORSEPOWER HEATING HEATER INSIDE DIAMETER INCHES KILOWATT LEAVING AIR TEMPERATURE POUNDS LEAVING WATER TEMPERATURE MIXED AIR MAXIMUM THOUSAND BTU'S PER HOUR MINIMUM MOTOR STARTER NOISE CRITERIA NOT TO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIAMETER PHASE FILE COPY POUNDS PER SQUARE CH (fin j {� G11). QUANTITY Permit No. IY `l "J OO. RETURN AIR REFRIGERANT Plan ref approval is subject to errors and omissions. RETURN Approval of construction documents does net author RELATIVE HUMIDift vlohigoo of anyadopted cede or ordinance. Recent RELIEF DAMPER�p� REVOLUTIONS PER earmiField Copy and conditions Is acknowledged: SUPPLY AIR �y;/ SEASONAL ENERGY EFFICIE=NE SENSIBLE HEAT Dom: SHUT OFF VALVE STATIC PRESSURE TEMPERATURE UNDERCUT DOOR VOLT VARIABLE AIR VOLUME VOLUME DAMPER (HAND VELOCITY WATT WITH WET BULB 1a4.Js+ . SEPARATE.' PERMIT REQUIRED FOR: ❑ Mochanical Electrical Plumbing ,'Gas Piping City of Tukwila BUILDING DIVISION t416P-OD 2' 8' 1 O 16' SCALE: 1 /8" = 1'-0" 1(0/?Ot5 City of Tukwila BUILDING DIVISION OPERATOR) REV1EwEo FOR 0O.DE COMPLIANCE APPROVED JUL 2 3 2015 I City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 1 2015 PERMIT CENTER SOUTHCENTE fV OCTEZU vIA w J JJ c Ld z w 0 5 0 0 J LU L w co co 03 rn w w rn z w J U DRAWN BY: HVAC COVERSHEET SCALE: AS -NOTED M1.0 PROJECT NORTH 7/16/2015 1t; t_S AN:) AF?hHLV AIIONS: 'r' = POINT 1. CC; N EC I 'CN 11; ..X S[INC I:) REMAIN r U A-t RE:.JRN A.:R. 1/41°' 1.0 (E.)RIL, 1 SUPPI )I ' FROM (' )'BEN 1 REBA0 CC TO P `;PVI E MAK 1A ,iV r0 ft W HOODS N r DJOI l C SPACES COL] HVAC PLAN 1/8" = 1'-0" v RELOCATED EXISTING 22 1 OOD ,1E.,,.; I.00D rr'2 - ;3): -CONS I 'FA oTi TC ;0Y _ \1 RiI"4 >.<` N`N(!.i'-='PA WI^C Ott r-�2 �1 UP -;-' (:E..)i -I *EFt.r?N A' :l :`:C'�!1 (1[)i;-:1 'S11PP',J AIR `( TO \} E3Y :5C DY _%A 4!1 N01111111111111111111)I ' ;i; 1 1 DEMO; EXIS ING, INLINE DISHWASHER.:''AN RECOIVNEG-I (EXISTING DISHWASHER HOOD AND 'RE L DUCTWORK 'DISHWASHER DUCT; UP TO, ROOF NO' NEW PENETRATIONS DEMO AND CAP ADJACENT; UNUSED,, EXHAUST ELBOW' SEE ATTACHED MARKUPED„ PICTURES' , , HV1- N.: J1 I-0 R 0 FOR FIR21'_ACES \ ; 95k EACH DEMO EXISTING UNUSED EXHAUST DUCT, AND CAP DEMO CAP, TRANSITION TO SQUARE TO ROUND, AND BUILD SUPPORTS EXISTING PENETRATION MAINTAINS 10' CLEAR FROM INTAKES -NO REROUTING REQUIRED ML5OO1 Z 2' 8' REVISIONS DESCRIPTION CITY OF TUKWILA CORRECTION #1 RESPONSE DATE N N O 4 0 N PLOT DATE 7/16/2015 ❑ DESIGN DEVELOPMENT DRAWING DATE DATE DATE DATE DATE COORDINATION PERMIT 2014. 10. 22 CONSTRUCTION AS BUILT REVIEWED FOR CODE COMPLIANC APPROVED JUL 2 3 2015 City of Tukwila i!,EtsIG DIVISIO CITY F TUR'WILA JUL 21 2015 PERMIT CENTER SOUTHCE\TE ivOCTEZUMA 633 WESTFIELD SOUTHCENTER MALL SEATTLE, WA 98188 di LLI 1— J 1— U m LL LLJ DRAWN BY: m 0.5 G U PROJECT MANAGER: RYAN JOHNSON L1 HVAC PLAN SCALE: AS —NOTED M1.1 0' 4' 16' SCALE: 1/8" = 11_O" PROJECT NORTH 7/16/2015 P:\Working Projects\Moctezumas DW Fan (215-0701)\Engineering\CAD Drawings\Moctezumas Southcenter\Sheets\M1.1 L1 HVAC PLAN.dwg Exhaust Fan Wiring JOB 2377015 - Moctezumas - Dish Fan DRAWING NUMBER EXH2377015-1 SHIP DATE 7/8/2015 MODEL DU85HFA 1 BK 2 o- I „ - 4 I RD 24v BK VTR-01 BK WH o24Vac o Neu Motor Control SC-01 BK Sw-01 3 oGR ---� 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 • WH MT-01 GR ri *REMOVE ORANGE JUMPER FOR 230/240V APPLICATI❑NS Installed Options Label MT-01 Component Identification Description Location Fan Motor C20 SC-01 EVO/ECM-VCU-36-MP C10 SW-01 Main disconnect switch [20 TR-01 24VAC 20VA TransformerClf MOTOR INF❑ EXHAUST 0.75HP-115V-1P-8.8FLA ELECTRICAL INF❑RMATI❑N M❑T❑R/CTRL MCA: 11,OA M❑T❑R/CTRL MOP: 15A NOTES - - - - DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE PR - PURPLE RD - RED PK - PINK WH - WHITE 2' 8' RECEIVED CITY OF TUKWILA JUL 2 1 2015 PERMIT CENTER cn z DESCRIPTION CITY OF TUKWILA CORRECTION #1 RESPONSE o rx w 1- 12014.10.22 PLOT DATE 7/16/2015 ® DESIGN DEVELOPMENT DRAWING DATE 0 DATE DATE 0 DATE 0 DATE COORDINATION PERMIT 2014. 10. 22 CONSTRUCTION AS BUILT SOUTHCENTER L.LJ U 0 2E J J Of LU I— Z UJ U E- O cn 0 J Lu E: (/7 ro Z uJ J U DRAWN BY: rn ir) Nm N LOO Lc) N Q N 0 cc'� r-• 00 W O ZcOLLI OfX .O W L.)��l�i Q Q Z Li 0 O APP OVED FIN, DE2TA3L 2015 City of Tukwila t ItDiNC DIVISION SCALE: AS -NOTED M1.2 0' SCALE: 1/8" = 1'-0" 16' PROJECT NORTH 7/16/2015 P:\Working Projects\Moctezumas DW Fan (215-0701)\Engineering\CAD Drawings\Moctezumas Southcenter\Sheets\M1.2 FAN DETAILS.dwa