Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0093 - RIVERTON MANAGEMENT OFFICE - OUTDOOR/INDOOR UNITS AND EXHAUST FANS
RWERTON MANAGEMENT OFFICE 14440 41sT AVE S M15-0093 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 0040000240 Permit Number: M15-0093 14440 41ST AVE S Project Name: RIVERTON MANAGEMENT OFFICE Issue Date: 8/20/2015 Permit Expires On: 2/16/2016 Owner: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 Contact Person: Name: STEVEN TRAN Address: Contractor: Name: Address: License No: Lender: Name: Address: 13620 1ST AVE S , BURIEN, WA, 98168 WASHINGTON HEATING & A/C INC 13620 FIRST AVE S , SEATTLE, WA, 98114 WASHIHA012LQ Phone: (206) 860-3832 Phone: (206) 860-3832 Expiration Date: 6/16/2016 DESCRIPTION OF WORK: PROVIDE AND INSTALL (1) 4 TON OUTDOOR UNIT CONNECTING TO (4) INDOOR UNITS AND (4) EXHAUST FANS PER PLANS Valuation of Work: $30,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $585.58 E►ectrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. c Signature: Print Name: Date: d -"p2.r7 iS This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWIL. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. K419 t1 X t Project No. IA/ Date Application Accepted: \'Date Application Expires: 1�(For ofice) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 0040000240 Site Address: 14440 41 Ave So. Suite Number: Floor: New Tenant: ❑ Yes O..No Tenant Name: Riverton Management Office Bldg G PROPERTY OWNER Name: King County Housing Authority Address: 600 Andover Park West City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Steven Tran Address: 13620 1st Ave So. City: Burien State: WA Zip: 98168 Phone: (206) 860-3832 Fax: (206) 860-3799 Email: stran@washingtonheating.com MECHANICAL CONTRACTOR INFORMATION Company Name: Washington Heating and A/C, Inc. Address: 13620 1st Ave So. City: Burien State: WA Zip: 98168 Phone: (206) 860-3832 Fax: (206) 860-3799 Contr Reg No.: WASHIHA012LQ Exp Date: 06/26/2016 Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Provide and install (1) 4 ton outdoor unit connecting to (4) indoor units, and (4) exhaust fans per plans 30,000 Use: Fuel Type: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement ❑ Electric 0 Gas ❑ Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 11-9-1 Ldocx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/ 1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER fl P1 HORIZED AGENT: Signature: Print Name: Steven Tran Mailing Address: 13620 1st Ave So. Date: 07/22/2015 Day Telephone: (206) 860-3832 Burien WA 98168 City State Zip H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ( ACCOUNT I QUANTITY PermitTRAK PAID $585.58 M15-0093 Address: 14440 41ST AVE S Apn: 0040000240 $585.58 MECHANICAL $563.06 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $417.95 PLAN CHECK FEE R000.322.102.00.00 0.00 $112.61 TECHNOLOGY FEE $22.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5780 R000.322.900.04.00 0.00 $22.52 $585.58 Date Paid: Wednesday, July 22, 2015 Paid By: STEVEN TRAN Pay Method: CREDIT CARD 00519G Printed: Wednesday, July 22, 2015 12:52 PM 1 of 1 OCI SYSTEMS INSPECTION RECORD Retain a copy with permit IN TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 (S'q3 Project: • (` J€ f w9ti1 a ce- Type of ��sp�ec ion: r (pl' ( Fe tR' Address: t-(d (14 1.( f= e—Id . Date Called: Special Instructions: A� #/vl Date Wanted: 1 0 —9.—(r a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: I Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1�7 INSPECTION RECORD _ . Retain a copy with permit NSP 10 �. �r 11 IT CITY OF TUKWILA BUILDIN �D1VI I 6300 Southcenter Blvd., #100, Tukwila. WA 98188 t (206) 431i-3670 Permit Inspection Request Line (206) 438-9350y q Ea'u f 10 (r-a6473 P ect: Type f Ins ctio ✓ A44 _4- i Addre s: Date C: Special ht Instructions: fi d L�. IP/�f Date W ntel: ci-/6 .a f�p.m. a.m. Requester: Phone No: Approved per applicable codes. L,1 Corrections required prior to approval. OMMENTS: f\ef-vil/ T 6 r--) r-flf-c—kf_p/t e-rcerf-vo✓ ' Cam, t('‘,(37) rritiva 1 11'vio Co Vefr- itva, Inspector: � "c ts— REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO 6300 Sou Permit Inspection Request Line (206) 438-9350 At (I- Oc7973 INSPECTION RECORD Retain a copy with permit ��''�� P€RMIT 0. C CITY OF TUKWILA BUILDIN©�`�Rig I `u thcenter Blvd., #100, Tukwila. WA 98188 06) 431-3670 Pro qct:✓er IA Akf. t. Ty q of Ins ection• f✓ 1'f rs: ® 7 6 Date Called: Special Instructions: 90-k-, i Q // Pm Date Wanted: -!_l-rJ a.m. p.m. Rester: Phone 5bZ VCR'7 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Moms % c?'<o( Inspector: Dateq REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. War ep YEN 7/LA178N/FAN Through -the -Wall Specification Submittal Data / Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise wall mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilating institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Four -pole totally enclosed condenser motor rated for continuous run. • Power Rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thermal -cutoff fuse. Mousing: • Rust proof paint, galvanized steel body. • Outside hood with built in backdraft damper and bird screen. • Expandable sleeve up to 10". Grille: • Attractive design using ABS material. • Attaches directly to housing. Warranty: • ALL Parts: For period of 3 years from the date of the original purchase. Architectural Specifications: Ventilating Fan shall be of the through - the -wall mount, ENERGY STAR rated type, with no less than 70 CFM and no more than 1.1 sone as certified by the Home Ventilating Institute (HVI). Power consumption shall be no greater than 18 watts and ENERGY STAR rated with efficiency rating of no less than 3.9 CFM/watt. The motor shall be totally enclosed, four pole condenser type engineered to run continuously. Power rating shall be 120v/60Hz. Duct diameter shalt be 8". Fan shall be UL and cUL listed for tub/shower enclosure when used with GFCI branch circuit wiring. Outside hood shall be painted steel with a spring damper and foam seal. Hood shall include a bird screen. Fan shall be ASHRAE 62.2, LEED, ENERGY STAR IAP, EarthCraft, California Title-24, and WA Ventilation Code compliant. Specifications: WhisperWall FV-08WQ1 Static Pressure in inches w.g. 0.03 Air Volume (CFM) 70 ..... Noise (sones) 1.1 Power Consumption (watts) 18 C Energy Efficiency (CFM/Watt) 3.9 Speed (RPM) 660 Energy Star Rated Yes Washington State VIAQ Code Yes REVtEWE ODE COM APPROVavvcl JUL 2 9 2015 FV 08WQ1 Grille -1/16 k 9-7/16 9-7/16 9-1/16 -� As of date 4/11 C of Tukwila For complete Installation Instructions visit www.panasonic I a. 10-1/4 2-1/16 3-15/3 rJ 9-27/32 L 31/32 8-1/32 10-1/4 14-5-29/32 N Exterior Hood CEIVED CITY OF TUKWILA JUL 2 2 2015 PERMIT CENTER Model Quantity LCOnnnents-�ma� Lt t: Riverton Terrace Apt Location: Tukwila, WA Architect: Engineer: Contractor: Washington Heating Submitted by: Steven Tran Date: Panasonic Nome and Environment Company Division of Panasonic Corporation of North America One Panasonic Way Secaucus, NJ 07094 www.panasonic.com/building r�" . et coat ��~i aysraow Mt9,ODCI?, VF11142SS 0 3 FILE u 0 -53 em \ O O roc, 0 0 E, 0 � A a4-3 cr CO 1 CO -0-0 A. Z -< c A REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 2 2015 PERMIT CENTER X1 0 m a m 3 s}uawpody uopa r I YMULTI Model: PUMP-P48NHMU*(-BS) MITSUBISH /\ ELECTRIC Job Name: Riverton Apartments Exterior Building Upgrades Schedule Reference:000-1 Date: OUTDOOR VRF SYSTEM FEATURES • Single-phase outdoor unit with variable refrigerant flow (VRF) zoning technology • Inverter -driven (variable speed) compressor • Total refrigerant piping length of 394' (120 m) • Uses CITY MULTI indoor units and Controls Network *UNIT OPTION e Standard Model PUMP P48NHMU ❑ Standard Model PUMP P48NHMUR4 ❑ Sea Coast (BS) Model PUMP P48NHMU-BS ❑ Sea Coast (BS) Model .PUMY-P48NHMUR4-BS OPTIONAL PARTS ❑ Joint Kit for details see Pipe Accesories Submittal III Header Kit for details see Pipe Accesories Submittal o Air Outlet Guide (One Piece)*'' PAC-SG59SG-E o Wind Baffle (One Piece)**.. WB-PA2 o Drain Pan PAC-SG64DP-E o Drain Socket PAC-SG61 DS-E o Drain Socket PAC-SH71DS-E *'PUMY requires one outlet guides or one wind baffles for installation. Specifications Model Name Unit Type PUMY-P48NHMU Nominal Cooling Capacity (208/230V) Btulh 48,000 Nominal Heating Capacity (208/230V) Btu/h 54,000 Operating Temperature Range Cooling (Outdoor) *1 23° F - 115° F (-5 ° - +46° C) DB* Heating (Outdoor) 0° F - +60° F (-18° - +15° C) WB External Dimensions (H x W x D) In. / mm 53-3/16 x 37-7/16 x 13 (+1-3/16) / 1,350 x 950 x 330 (+30) Net Weight Lbs. / kg 287 / 130 External finish Precoated Galvanized -steel Sheets Electrical Power Requirements Voltage, Phase, Hertz 208 / 230V, 1-phase, 60Hz Minimum Circuit Ampacity (MCA) A 26 Recommended Fuse/Breaker Size A 30 Maximum Fuse Size A 40 Piping Diameter (Flared) (In. / mm) Liquid (High Pressure) 3/8 / 9.52 Gas (Low Pressure) 5/8 / 15.88 Indoor Unit Total Capacity 50 to 130% of Outdoor Unit Capacity Model / Quantity P06 to P54 / 1 to 8 Sound Pressure Levels dB(A) 50/52 Fan Type x Quantity Propeller Fan x 2 Airflow Rate CFM 3,530 Direct -drive Inverter Motor Output kW 0.086 Compressor Operating Range 25% to 100% Compressor Type x Quantity Inverter -driven Scroll Hermetic x 1 Compressor Motor Output kW 2.4 Refrigerant R410A Lubricant FV5OS High-pressure Protection Device 601 psi / 4.15 MPa Compressor 1 Fan Protection Device Overheat Protection / Thermal Switch Inverter Protection Device Overheat / Overcurrent Protection AHRI Ratings (Ducted / Non -Ducted) EER 8.40 / 9.00 SEER 14.5 / 15.5 COP 3.56 / 3.14 Blue Fin Anticorrosion Protection: Cellulose- and polyurethane -resin coating treatment applied to condenser coil that protects it from air contaminants; 1 pm thick; Salt Spray Test Method - no unusual rust development to 240 hours. NOTES: *1. If PKFY-P06/08 indoor units are connected, then range is 50° F -115° F (10° C - 46° C). SEACOAST PROTECTION -External Panel Base, Extemal Front Panel, Pillar. Alloyed galvanized -steel sheets with thermoset polyester -resin coating on internal and extemal surfaces •Compressor Cover: Galvanized -aluminum sheets with thermoset polyester -resin coating on intemal and extemal surfaces -Electrical Parts Box: Galvanized -aluminum sheets with thermoset polyester -resin coating on extemal surface •Fan Motor Support: Galvanized -steel sheets with thermoset polyester -resin coating on internal and external surfaces -Printed Circuit Board: Epoxy resin with polyurethane -coating on external surface Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. Model: PUMY-P48NHMU*(-BS) - DIMENSIONS :Eeu$:eulS�l+p3 ee :e�: o= 2:iraa4iG o eo vs-_-«ooconae_e: coa_ee oema ea ruii9ni CERTIFIED,, Unitary Small HP 0,1,11 Standard 210R40 GUS Intertek Ref.: PUMY_NHMU_EXD_USDB_P36-48 Unit mm(inj ArtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# PUMY-P48NHMU'(-BS) - 201408 Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. ITYMULTr Model: PKFY-P08NHMU-E2 iw MITSUBISHI ELECTRIC Job Name: Riverton Apartments Exterior Building Upgrades Schedule Reference: ICU-3 Date: GENERAL FEATURES • Dual set point functionality • Compact, lightweight, shiny -white, flat -panel design • Quiet operation • Multiple fan -speed settings • Intake grille filter is easily removed for cleaning • Wireless receiver on board OPTIONS ❑ Condensate Pump SI3100-230 ❑ CN24 Relay Kit CN24RELAY KIT-CM3 SPECIFICATIONS Capacity* Cooling 8,000 Btu/h Heating 9,000 Btu/h Power Power Source 208 / 230V, 1-phase, 60Hz Power Consumption Cooling 0.03 kW Heating 0.03 kW Current Cooling 0.30 A Heating 0.30 A Minimum Circuit Ampacity (MCA) 0.38 A Maximum Overcurrent Protection (MOCP) Fuse 15 A ExternalFinish MunsellNo.1.0Y9.2/0.2 External Dimensions Inches 11-5/8 H x 35-3/8 W x 9-13/16 D mm 295Hx898Wx249D Net Weight Unit 29 lbs. / 13 kg Coil Type Cross Fin (Aluminum Plate Fin and Copper Tube) Fan Type x Quantity Line Flow Fan x 1 Airflow Rate (Low - Mid - High)... 320 - 370 - 413 CFM Motor Type Direct -drive DC Motor Air Filter.. Polypropylene Honeycomb Refrigerant Piping Dimensions Liquid (High Pressure) 1/4" / 6.35 mm (Flare) Gas (Low Pressure) 1/2" / 12.7 mm (Flare) Drainpipe Dimension I D. 5/8" / 16 mm Sound Pressure Levels Low -Mid -High 34 - 39 - 43 dB(A) * Cooling / Heating capacity indicated at the maximum value at operation under the following conditions: Cooling 1 Indoor: 80° F (27° C) DB / 67° F (19° C) WB, Outdoor 95° F (35° C) DB Heating 1 Indoor: 70° F (21° C) DB, Outdoor 47° F (8° C) DB / 43° F (6° C) WB Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Model: PKFY-P08NHMU-E2- DIMENSIONS 11v.gl52* (Res 4 ml 1005)0 NI rs N1e 6(12.5) to 0 n0 Teo* To side Front side 1 1 1 1 1 l 1 1 �r.'rl � 2-1)6 27.111616661 a6,116(155) (55) 355)15(890) font aide(Gdle open) Oi I:11 ■ ISM iii1111 111� -- ■lll■ 1T-IS116(253(54s Ppo I� 6-SR(1691 w1mmm wFEINEBIN 4- 05116(R9) Bolt hde 11-03016105.11 0 5/805)1 1-1I18(28.5) 1.906(41) 31/16(78.5) 39116 91 411161104.Sj 40/164116) 6-1/2(166) 7(178.5) 9-56(2328,9) 9-15I16)253 5) 1.01 1-11116(43 1 6)4 Bill 2.5116(50) na, Unit : in(mm) Fight vh g.31d(2491 16(51 Nnodlanlwle for right piping for Ten. Wok f. MenKKe rnn6ala (mo6ng4teati,g) 6M9 . Iquupp 00051..1 8.1v 10;10120 o+.. �. 05014010 Center measurement hde 03)32 02 Indoor unit outline 13,16(2,81 0 L4)20) 1-1w(32.T 2,06(535) 2-9116(66) 5(128.5) 6(153.5) 91)16(231.51 1930(223.2) us (6moo Intertek jwMITSUBISHI ELECTRIC FORM# PKFY-P08NBMU-E2 - 201306 COOLING & HEATING 1340 Satellite Boulevard Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Live Better ITYM U LTI`R) Model: PKFY-P12NHMU-E2 i MITSUBISHI ELECTRIC Job Name: Riverton Apartments Exterior Building Upgrades Schedule Reference: ICU-1 Date: MOW GENERAL FEATURES • Dual set point functionality • Compact, lightweight, shiny -white, flat -panel design • Quiet operation • Multiple fan -speed settings • Intake grille filter is easily removed for cleaning • Wireless receiver on board OPTIONS o Condensate Pump SI3100-230 o CN24 Relay Kit CN24RELAY-KIT-CM3 SPECIFICATIONS Capacity* Cooling 12,000 Btu/h Heating 13,500 Btu/h Power Power Source 208 / 230V, 1-phase, 60Hz Power Consumption Cooling 0.03 kW Heating 0.03 kW Current Cooling 0.30 A Heating 0.30 A Minimum Circuit Ampacity (MCA) 0.38 A Maximum Overcurrent Protection (MOCP) Fuse 15 A ExternalFinish MunsellNo.1.0Y9.2/0.2 External Dimensions Inches 11-5/8 H x 35-3/8 W x 9-13/16 D mm 295Hx898Wx249D Net Weight Unit 29 lbs. / 13 kg Coil Type Cross Fin (Aluminum Plate Fin and Copper Tube) Fan Type x Quantity Line Flow Fan x 1 Airflow Rate (Low -Mid -High) 320 - 370 - 413 CFM Motor Type Direct -drive DC Motor Air Filter.. Polypropylene Honeycomb , Refrigerant Piping Dimensions Liquid (High Pressure) 1/4" / 6.35 mm (Flare) Gas (Low Pressure) 1/2" / 12.7 mm (Flare) Drainpipe Dimension I D. 5/8" / 16 mm Sound Pressure Levels Low -Mid -High 34 - 38 - 42 dB(A) * Cooling / Heating capacity indicated at the maximum value at operation under the following conditions: Cooling I Indoor. 80° F (27° C) DB / 67° F (19° C) WB, Outdoor 95° F (35° C) DB Heating I Indoor: 70* F (21 ° C) DB, Outdoor 47° F (8° C) DB / 43° F (6° C) WB Notes: Specifications are subject to change without notice. © 2012 Mitsubishi Electric & Electronics USA, Inc. Model: PKFY-P12NHMU-E2 - DIMENSIONS tptiase41erake 11ewet; r 42.Ire file 14sc4 sot z4111 (ea5 4e41 Knock out hole for 60ng 7/15(12.51 1)11116(13) tomb wd me 1wmdPo 15-3116 3B7 7-112192 Top side a 23.9116(5991 Front side 11 a a i I • I . ,. 2-11` 11BI 27-1/16(686) �61/�)� (55) 356/16(090) t aide soma 1!fiiiii!!ii! 1.111111110111111111,111EMIl 1 IN ■. 17-15116(4571Gas4pe 'l 65R1169) Unit : in(mm) boa Right aide II A 6914(249) /16(5 Knob out hole /ern9M FON emmnal dock f for vansm.cd) Terminal dock for MArornote mnlrole, Emerges operation switch (000.1.03))B) were) alas 24.1116(612) eSon DEFROST/SUM] BY lamp ton. aart4sa9 a.,0, tnr14t/6 oe+mw. dse tOsno 2 7743116145.11 Tappv,9 awewhde 2-5116(60 Lauver 4-05/16(09) Bolt hole G -11/ 6(13) Knob outhole fa. lower N9 sin holoe lw i6 e. Recerve Center measurement hole 43132 42 Mount board Indoor unit outline 13/16(21.B) d(2o) 2.1)4(323) 2-911 66) 5(12B.5) 6(153.5) 61(1N23 70-3/4)273.21 GUS Lis rev Intertek FORM# PKFY-P12NHMU-E2 - 201301 Specifications are subject to change without notice. © 2012 Mitsubishi Electric & Electronics USA, Inc. ArtMITSUBISHI ELECTRIC COOLING & HEATING Live Better 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678-376-2900 . Fax: 800-889-9904 Toll Free: 800-433-4822 (#4) www.mitsubishipro.com Specifications are subject to change without notice. ITYMULTI® Model: PKFY-P15NHMU-E2 mw MITSUBISHI ELECTRIC Job Name: Riverton Apartments Exterior Building Upgrades Schedule Reference: ICU-2 Date: GENERAL FEATURES • Dual set point functionality • Compact, lightweight, shiny -white, flat -panel design • Quiet operation • Multiple fan -speed settings • Intake grille filter is easily removed for cleaning • Wireless receiver on board OPTIONS ❑ Condensate Pump SI3100-230 ❑ CN24 Relay Kit CN24RELAY KIT-CM3 SPECIFICATIONS Capacity* Cooling 15,000 Btu/h Heating 17,000 Btu/h Power Power Source 208 / 230V, 1-phase, 60Hz Power Consumption Cooling 0.03 kW Heating 0.03 kW Current Cooling... 0.30 A Heating 0.30 A Minimum Circuit Ampacity (MCA) 0.38 A Maximum Overcurrent Protection (MOCP) Fuse 15 A ExternalFinish MunsellNo.1.0Y9.2/0.2 External Dimensions Inches 11-5/8 H x 35-3/8 W x 9-13/16 D mm 295Hx898Wx249D Net Weight Unit 29 lbs. / 13 kg Coil Type Cross Fin (Aluminum Plate Fin and Copper Tube) Fan Type x Quantity Line Flow Fan x 1 Airflow Rate (Low -Mid -High) 320 - 370 - 413 CFM Motor Type Direct -drive DC Motor Air Filter Polypropylene Honeycomb Refrigerant Piping Dimensions Liquid (High Pressure) 1/4" / 6.35 mm (Flare) Gas (Low Pressure) 1/2" / 12.7 mm (Flare) Drainpipe Dimension I D. 5/8" / 16 mm Sound Pressure Levels Low -Mid -High 34 - 39 - 43 dB(A) * Cooling / Heating capacity indicated at the maximum value at operation under the following conditions: Cooling l Indoor: 80° F (27° C) DB / 67° F (19° C) WB, Outdoor 95° F (35° C) DB Heating 1 Indoor: 70° F (21 ° C) DB, Outdoor 47° F (8° C) DB / 43° F (6° C) WB Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Model: PKFY-P15NHMU-E2 - DIMENSIONS ea,lr4s,e owl). as,742.14 IAa4m1 7/16(12.5 Knock Mhole for piping A 1-11/16(43) Knock oul nae Iw lower piping Top sole [\1 Tyr 1 1 1 1 • . 1 2-1lel 27-1116)684) 461116(155) (55) 35-5/16(898) 1 17-15/161457(G Pe 69) 21 3I16(53911qud pipe 24(610)3ramxose Unit : in(mm) mnt board fight silo 4314(249) 3116(5) Know for 9 ilia Te d dice Temnal dakle dAee,olemueeer 63f1611581 foxansne.:,glaumswiW, /161194) el under 24.1/16(612) Ee Op e,c4m I DEFROST/STAND9 v .amial ENI=rI1111111rallill nmk anlMe Reoer tor rower p0n9 n-03ne(05.1) Tappxg screw xdo 4-05/16(09) Boll hol Center measurement hole Maunl board r►P��e�C_Ii;IrC��:peeGa� it em gmmimoio le44; ,1o10aa7 .11011 Ins 102n D•^58n 5454(060n Indoor unit outline 111601.9) •11) 6(49) I �11➢� azoli 14)40) 1-114(32.7t 2-1/16(52.a) 2A/16(96) 5(128.5) 6)153.5) 41116(231.5) 10314(273,2) us &18TEO Intertek FORM# PKFY-P15NHMU-E2 - 201301 Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. AikMITSUBISHI ELECTRIC COOLING & HEATING Live Better 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Toll Free: 800-433-4822 (#4) www.mitsubishipro.com Specifications are subject to change without notice. ITYMULTI°' Model: PAR-U01MEDU-J MITSUBISHI ELECTRIC Job Name: Riverton Apartments Exterior Building Upgrades Schedule Reference: Quantity 04 Date: • ...rotIMJEttSre ELECTRIC. ■ System example Smart ME remote controller Smart ME remote controller SMART ME REMOTE CONTROLLER (PAR-UOIMEDU-J) SPECIFICATIONS • Backlit touch screen wall -mounted remote controller • Controls group operation: - Up to 16 indoor units in a single group - One Advanced HVAC Controller (DC-A2I0) • Displays: - Temperature (° F and ° C) - Relative Humidity - Occupancy (customizable) - Operation status - Four -digit error code and error unit address (customizable) • User defined indoor unit functions: - On/Off - Monitoring and Operation - Operation mode: o Auto* (Dual or Single set point) o Cool o Heat o Fan o Drying o Setback* Note: *R2 Series only (connected equipment dependent) - Set temperature - Fan speed setting - Airflow direction - Louver setting - Set temperature range: 40° F - 95° F (operation mode and connected indoor unit dependent) • HOLD feature enables/disables the timers and auto return function • Permits or prohibits remote controller functions: - On/Off - Temperature Setting - Mode - Fan Speed - Vane Direction - Filter Sign Reset • Room temperature can be sensed either at the indoor unit (default) or at the remote controller • Set temperature range limit: allowable set temperature range can be reduced for each operation mode • Adjustable setback override timer (2-hour default) • Interlocked systems can set high/low/stop on LOSSNAY® units • Grouping: - A maximum of two PAR-U01 MEDU Smart ME Remote Controllers can control a single group of indoor units - Other types of remote controllers cannot be paired • Addressing: M-Net Address using rotary dials • Wiring: - Two -wire - Stranded - Non -polar control wire • Dimensions: 5-9/16 x 4-3/4 x 1 in. (140 x 120 x 25 mm) Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Model: PAR-U01 MEDU-J - Dimensions Notes: FORM# PAR-U01MEDU-J - 201306 Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. ArtMITSUBISHI ELECTRIC COOLING & HEATING Live Better 1340 Satellite Boulevard Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Toll Free: 800-433-4822 www.mehvac.com HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0093 DATE: 07/24/15 PROJECT NAME: RIVERTON MANAGEMENT OFFICE SITE ADDRESS: 14440 41ST AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: POO /► l\�1 Building Division IN Public Works ❑ M'\ M\ n\V6 Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/28/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 08/25/15 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WASHINGTON HEATING & A/C 'TC Page 1 of 2 Home Inicio en Fspanol Contact Search L&I A-Z, Index Help My Secure 1,&I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries WASHINGTON HEATING & A/C INC Owner or tradesperson Principals TRAN, STEVEN c, PRESIDENT LONG, MONTHEA R, VICE PRESIDENT PECH, MAKARA, SECRETARY (End: 05/30/2008) LONG, MAKARA, PRESIDENT (End: 06/17/2008) Doing business as WASHINGTON HEATING & A/C INC WA UBI No. 601 962 099 13620 FIRST AVE S SEATTLE, WA 206-860-3832 KING County Business type Corporation Governing persons MONTHEA R LONG STEVEN TRAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................................................................... Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. WASHIHA012LQ Effective — expiration 06/18/1999— 06/16/2016 Bond .............._. Developers Surety & Indem Co Bond account no. 252216C Received by L&I 05/25/2011 Bond history Insurance ... _....................... Ohio Security Ins Co Policy no. BKS53513733 $6,000.00 Effective date 06/16/2011 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601962099&LIC=WASHIHA012LQ&SAW= 8/20/2015