Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0094 - GATEWAY 7 - ROOFTOP UNIT
GATEWAY 7 12720 GATEWAY DR EXPIRED 04/19/16 M13-0094 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2716000070 12720 GATEWAY DR Project Name: GATEWAY 7 MECHANICAL PERMIT Permit Number: M15-0094 Issue Date: 8/12/2015 Permit Expires On: 2/8/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT #207 PO BOX 4900 , SCOTTSDALE, WA, 85261 BLAKE BJORNSON 7717 DETROIT AVE SW , SEATTLE, WA, 98106 MACDONALD MILLER FACIL SOLUTIO PO BOX 47983 , SEATTLE, WA, 98146- 7983 MACDOFS980RU Phone: (206) 905-3780 Phone: (206) 768-4180 Expiration Date: DESCRIPTION OF WORK: REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT ON EXISTING CURB. RECONNECT NATURAL GAS LINE PIPING AND ELECTRICAL PER PLANS. Valuation of Work: $19,142.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $454.94 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: ^ C —( S I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: -�" /lovf Date: W2/6--- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshal's Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. fr);Soon Project No. Date Application Accepted: Date Application Expires: o7p7/d (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 2716000070 12720 Gateway Drive S Tukwila, WA 98168 GATEWAY 7 PROPERTY OWNER Name: BOEING EMPLOYEE'S CREDIT UNION Address: 12720 GATEWAY DRIVE S City: TUKWILA State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: BLAKE BJORNSON Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 905-3780 Fax: (253) 905-3781 Email: blake.bjornson@macmiller.com Suite Number: ROOF Floor: ROOF New Tenant: El Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: MACDOFS980RU Exp Date: 01/03/2017 Tukwila Business License No.: BUS-0100868 Valuation of project (contractor's bid price): $ 19,142 Describe the scope of work in detail: REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT ON EXISTING CURB. RECONNECT NATURAL GAS LINE PIPING AND ELECTICAL PER PLANS. Use: Residential: New ❑ Replacement 0 Commercial: New ❑ Replacement Fuel Type: Electric WI Gas Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin 1 Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator - domestic Incinerator - comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER rAUTHO D AGE Signature: � � V - ^ Date: 07/27/2015 Print Name: DARLA DOLL Day Telephone: (206) 768-4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip H:\Applications\Fomu-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $454.94 M15-0094 Address: 12720 GATEWAY DR Apn: 2716000070 $454.94 MECHANICAL $437.44 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $317.45 PLAN CHECK FEE R000.322.102.00.00 0.00 $87.49 TECHNOLOGY FEE $17.50 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5807 R000.322.900.04.00 0.00 $17.50 $454.94 Date Paid: Monday, July 27, 2015 Paid By: MACDONALD-MILLER FACILITY SOLU Pay Method: CHECK 4276 Printed: Monday, July 27, 2015 1:33 PM 1 of 1 CTRYFf SYSTEMS INSPECTION RECORD Retain a copy with permit PERMIT NO. AA is.40q1-4 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 9818$,a _ S (2 ) 43163�0 Permit Inspection Request Line (206) 438-9350 ��U''tgl� 6CA Type gf,lmio , 1 rekct Address -,,Date (, 7.1 Dr , Called: Special Instructions: • e ) IN 4~ VIA( V' c (0WM Date Wanted: (0 --'22---. ‘,- a.m. p.m. Regtss ter: `/tJI Phone No: 206 - 3q ( 6 c ( a 0 Approved per applicable codes. •1 Corrections required prior to approval. COMMENTS: c- re. 4f— dZCKZIle CIL D qe-q-Vrec—ct ( (U $ lifri — 0 ,76 fgEF41; jtt.t.SIe dr, c 1 - a 1.-- & it, 0 P (rye, �lcc"- - 1 r Fri d t- 1 2t5 qfipt v? .4' f 4/171--ram" c `] CSC t v- le-eft/IVY C o f Inspector: Date. ©-z—/S-- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 3/1/2016 BLAKE BJORNSON 7717 DETROIT AVE SW SEATTLE, WA 98106 RE: Permit No. M15-0094 GATEWAY 7 12720 GATEWAY DR Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/19/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/19/2016, your permit will become null,and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, )-vit Bill Rambo Permit Technician File No: M15-0094 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0094 PROJECT NAME: GATEWAY 7 SITE ADDRESS: 12720 GATEWAY DR S X Original Plan Submittal Response to Correction Letter # DATE: 07/27/15 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: kivU Aci Building Division Public Works ❑ Prw G PM VIA Fire Prevention Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/28/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/25/15 Approved Approved with Conditions Corrections Required ❑ Denied (ie: Zoning Issues) (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/ 18/2013 MACDONALD/MILLER FAC SOT TC Page 1 of 3 Home Inicio en Espanol Contact Search L&I A-Z.Index Help My Secure Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries MACDONALD/MILLER FAC SOL INC Owner or tradesperson Principals SIMONDS, DERRICK R, PRESIDENT WEBSTER, MARK E, VICE PRESIDENT GEBHARDT, STEPHANIE WETTACH, TREASURER HOEL, STEPHANIE W, MEMBER SIGMUND, FREDRIC, PRESIDENT (End: 01/04/2011) LOVELY, STEVE C, VICE PRESIDENT (End: 01/04/2011) HACK, RICHARD, SECRETARY (End: 01/04/2011) KOPET, TYLER, TREASURER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF EXECUTIVE OFFICER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF OPERATING OFFICER (End: 01/04/2011) GOUGH, DAVID ANTHONY, DIRECTOR (End: 08/29/2014) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No. 602 254 260 PO BOX 47983 SEATTLE, WA 98106 206-768-4180 KING County Business type Corporation Governing persons FREDRIC J SIGMUND STEVE C LOVELY; TYLER C KOPET; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MACDOFS980RU Effective — expiration 12/31/2002— 01/03/2017 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 8/12/2015 o � W �' �s"'I o co D NI. ct CD 103 Replacement — OPTION 2 Carrier J:\7315\6577 Gateway 7 — Monday, July 27, 2015 9:47:25 UNIT NO. RTU-101 MFG & MODEL NO. CARRIER 48AKT050DSQ611 HM NOM TONS 50.0 INPUT GAS HEAT MBH OUTPUT 656.00 800 CFM 20,000 ESP 1.2 FAN HP 30.0 OSA CFM 3,680 EER/ SEER 9.3 IPLV /IEER 9.5 ELECTRICAL VOLT/PH 460/3 MCA 150 INT LBS 6,658 NOTES EXISTING RTU-102 CARRIER 48A3T060DSV611 HM 60.0 1164 954.00 24,000 1.2 30.0 7,200 10.1 9.5 460/3 174 8,521 EXISTING RTU-103 CARRIER 48TCDD14A3A6-0A0G0 12.5 180 148.00 5,000 0.5 4.0 10.8 11.8 460/3 31 1,277 REPLACE, 1-6 NOTES: 1. ELECTRICAL DISCONNECT SWITCH AND POWER WIRING BY E.C. 2. VFD MOTORS 3. FEATURES AND OPTIONS INCLUDE: HIGH STATIC OPTION (BELT DRIVE) AUCU COND AND EVAP BASE ELECTROMECHANICAL CONTROLS STANDARD PACKAGING 2-SPEED INDOOR FAN MOTOR CONTROLLEC BY VFD ECONOMIZER AND BAROMETRIC RELIEF 4. MAXIMUM SOUND POWER LEVEL OF 87 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 5. NEW UNIT WEIGHT (1,277 LBS) IS LESS THAN UNIT REPLACED (1,287 LBS). NO STRUCTURAL REVIEW REQUIRED PER CITY OF TUKWILA. 6. LIKE -FOR -LIKE REPLACEMENT 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRyD. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. "p 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2012 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2012 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL-11OT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2012 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2012 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2012 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. )� era: 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 11. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL ,':IR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER TITLE PROJECT ENGINEER ACCOUNT MANAGER SHEET METAL FOREMAN SHEET METAL FOREMAN AIR BALANCE FOREMAN REFRIGERATION FOREMAN FACILITIES DIRECTOR NAME BLAKE BJORNSON STEVE FLINK CHRIS HOLLINGSWORTH TIM FELTON RON LANDBERG DEAN GRASSER PETER KELLY COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER CBRE PHONE NUMBER 206-905-3780 253-680-3172 206-407-2620 206-407-2692 206-571-2661 206-768-4270 253-398-9034 EMAIL BLAKE. BJORNSON @MACM ILLER.COM STEVE.FLI N K@MACM ILLER.COM CH RIS.HOLLI NGSWORTH@MACM ILLER.COM TI M. FELTON@MACMILLER.COM RON. LAN DBERG@MACM ILLER.COM DEAN.GRASSER@MACM I LLER.COM PETER.KELLY@CBRE.COM NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01S SITE PLAN TM2.03 ROOF PLAN AND ELEVATION REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT ON EXISTING CURB. RECONNECT EXISTING NATURAL GAS LINE TO NEW ROOFTOP UNIT. ELECTRICAL DISCONNECT/CONNECT FOR NEW ROOFTOP UNIT. AIR BALANCE (1) RTU. APN# 2716000070 LEGAL DESCRIPTION: GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89-1-SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER. REV1S1S Ma changes shall � to the scope 01 work without prior approval of Tukwila Building Division. NOTE Revisions requiro a new Om subnottat and may int'ude additional Wan ra% .71:z3 S133RD ST \DUWAMISH RIB 48TH AVE S INTERURBAN AVE S VICINITY MAP NO SCALE APR 1.9. 2 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical 413'EIectricai ►rsmbing Gas Piping City of Tukwila BUILDING DIVISION FILE COPY it No. MI5 Imo! ra approval is subject to errors end Appnwal of construction docwnents does .; of any adopt code cr ordnance. of approved Reki Copy and c• Meg ll2 /i. CI y of Tukwila BUILD NC DIVISION REVISIONS: -. Lu I < r o N I N 0 I I I I I I l< z w w 0 0_ w RECEIVED CITY OF TUKWILA JUL 2 7 2015 F- PERMIT CENTER ENGINEER: B BJORNSON CHECKED BY: GEZON REVISIONS: z 0 0 z 0 0 0 LL 0 w ( ) 0 LAST REVISED: 07-27-15 DATE PLOTTED: 07-27-15 ISSUE DATE LAMBERT 07-27-15 NG NUMBER: E-0182-731 5. 6577-00 SHEET NUMBER: TMO,„,,. 1 CODE COMPLIANCE APPROVED ,/ AUG 052015 Citjr of Tukwila BUILDING DIVISION / co 6; Csi 0 0 L.,. c.o no or-- a) coo) r..1.co ce ▪ 7, < cc c. • 2 . N.- co _ a:. a) o 0) F— 1 row ,,35 8 u_ -0 ___• 1 2 a 0 c o g. 1 0 ci) < — 0 1 1-- (Sc.' co > o 0 1 < (N.., z 0 _._... ('a0 . 8 _1 r) C \ CO 1 ' S a '6 < r- 2 . CO r-- .c I-- o_ I I I I I IuJ I I 0 I I I I I I I I REVISIONS: II tiJ 0 z 0 01= z 0 I I I I I I l< z LU 3- 0) REVISIONS: RECEIVED CITY OF TUKWILA JUL 2 7 2015 PERMIT CENTER z 0 0 H (/) z 0 0 u_ 0 0 z ENGINEER: LAST REVISED: B BJORNSON 07-24-15 CHECKED BY: B GEZON CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: E-0182-7315-6577-00 SHEET NUMBER: DATE PLOTTED: 07-24-15 WEDFOR ODE COMPLIANCE. APPROVED AUG 0 5 2015 • City of Tukwila UILDING DIVISION. M csi Cfl Ci n Ci 0' rn cc 0 w O 0 L_ cn OPTION 2 Carrier / II SCREEN WALL RTU-102 REPLACE RTU-103 RECONNECT NEW UNIT TO EXISTING NATURAL GAS LINE AND ELECTRICAL SERVICE LIKE -FOR -LIKE REPLACEMENT. SAME SIZE, SAME CAPACITY, SAME CURB. A -A REFER PIPING ROUTED TO THE INDOOR UNIT ELECTRICAL CONDUIT TO THE INDOOR UNIT BY E.C. CONDENSING UNIT INSTALLED ON SLEEPER WITH NEOPRENE ISOLATION. SLEEPERS PROVIDED AND INSTALLED BY G.C. ALL CUTTING AND PATCHING OF THE ROOF BY G.C. OU-1 / G -RAL \OT J: 6� 1 1. NOT ALL ROOF -MOUNTED EQUIPMENT IS SHOWN. -LAG \OT —Se 50 TON MODEL CARRIER 48AKTO5DSQ61 1 HM. [EXISTING] CARRIER WEATHER MAKER SINGLE -PACKAGED 60-TON ROOFTOP UNIT. MODEL# 48A3T060DSV61 1 HM. CARRIER WEATHER MAKER SINGLE -PACKAGED ROOFTOP UNIT. MODEL# 48TJD014. SERIES# 601 QE. SERIAL# 4194G30497. [EXISTING] REPLACE WITH CARRIER MODEL #48TC D D 14A3A6 -OA0 G0 l PARAPET WALL SCREEN WALL RTU-101 36'-0" RTU-103 0 7.1 SLAB N RTU-103 WEST ELEVATION NO SCALE 16' - 8" RTU-103 , —PARAPET WALL 0 RTU-103 SOUTH ELEVATION NO SCALE 1 1 1 1 1 1 1 1 1 1 1 1 REPLACEMENT O Ct nL 1 0 0 0 0 CI) („) o� coco rn� < aio N N co u. O a)c) • 'e co L Q 0 N 0 ;6 o a 1 1 1 1;21 N N I A 0 E U 0 E U E O co 0 U) 0 2 z U RECEIVED CITY OF TUKWILA JUL 27 2015 PERMIT CENTER w 0Q REVISIONS: 0 REVISIONS: z 0 U U) z 0 0 0 LL 0 LU v ) 0 z ENGINEER: LAST REVISED: B BJORNSON 07-27-15 CHECKED BY: DATE PLOTTED: B GEZON 07-27-15 CAD: ISSUE DATE D LAMBERT 07-27-15 DRAWING NUMBER: E-0182-7315-6577-00 SHEET NUMBER: TM2.03 Monday, July 27, 2015 9:47:08 TM2.0 1 1 /8" = 1'-O" REVfEWED FOR EOPE COMPLIANCE APPROVED AUG -D0-5.2015 I DING �a C t fTukwi1a t DIVISION`