HomeMy WebLinkAboutPermit M15-0099 - MUSEUM OF FLIGHT - 787 - HEAT PUMP, FAN, DUCTWORK, CONTROL ETCMUSEUM OF FLIGHT 787 9229 E MARGINAL WAY S M16-0099 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 5729800020 9229 E MARGINAL WAY S MECHANICAL PERMIT Project Name: MUSEUM OF FLIGHT- 787 Permit Number: Issue Date: Permit Expires On: M15-0099 8/31/2015 2/27/2016 Owner: Name: Address: Contact Person: Name: MUSEUM OF FLIGHT FOUNDATION 9404 E MARGINAL WAY S , SEATTLE, WA, 98108 FENTON KRAFT Address: 9404 E MARGINAL WAY S , TUKWILA, WA, 98108 Contractor: Name: AFFIDAVIT- FENTON KRAFT Address: License No: Lender: Name: Address: 111 Phone: (206) 795-5831 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL NEW SPLIT SYSTEM HEAT PUMP, PRESSURE BOOSTER FAN, DUCT WORK, SENSORS AND AUTOMATION EQUIPMENT TO CONTROL TEMP AND HUMIDITY LEVELS INSIDE THE MUSEUMS 787. Valuation of Work: $39,471.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $716.24 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: c{� Date: 60 3/20/t Print Name: 14413 t6✓a+F This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshal's Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 15: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: ***MECHANICAL PERMIT CONDITIONS*** 21: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 22: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0609 0705 0701 0702 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL SMOKE DETECTOR TEST a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. NI1g-CD161 Date Application Accepted: Date Application Ex ir/A Expires: (For office use only ) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 9404 East Marginal Way South Tenant Names Museum of Flight King Co Assessor's Tax No.: 33-2404-901.9 Suite Number: New Tenant: PROPERTY OWNER Name: Museum of Flight Foundation Address: 9404 East Marginal Way South City: Tukwila State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Fenton Kraft Address: 9404 East Marginal Way South City: Tukwila State: WA Zip: 98108 Phone: (206) 795-5831 Fax: (206) 764-5707 Email: fkraft@museumofflight.org Floor: N/A ❑ Yes j..No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 39,471 Describe the scope of work in detail: Install a new split system heat pump (HP), pressure booster fan, duct -work, sensors and automation equipment to control temperature and humidity levels inside the Museum's recently donated Boeing 787. All equipment except the HP outdoor unit will be installed in the 787's forward cargo bay and will be secured utilizing the existing cargo retention system. HP rating IEER=22.7 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric m Gas ❑ Other: H:\ApplicationslForms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm I. Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 4..it,,,1L 3 Date: 07/30/2015 Print Name: Fenton Kraft Mailing Address: 9404 East Marginal Way South Day Telephone: (206) 795-5831 Tukwila WA 98108 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $1,059.29 EL15-0661 Address: 9229 E MARGINAL WAY S Apn: 5729800020 $343.05 ELECTRICAL $317.63 PLAN CHECK FEE R000.345.832.00.00 0.00 $63.53 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $254.10 TECHNOLOGY FEE $25.42 TECHNOLOGY FEE R000.322.900.04.00 0.00 $12.71 TECHNOLOGY FEE R000.322.900.04.00 0.00 $12.71 M15-0099 Address: 9229 E MARGINAL WAY S Apn: 5729800020 $716.24 MECHANICAL $688.69 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $518.45 PLAN CHECK FEE R000.322.102.00.00 0.00 $137.74 TECHNOLOGY FEE $27.55 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5844 R000.322.900.04.00 0.00 $27.55 $1,059.2.9 Date Paid: Friday, July 31, 2015 Paid By: MUSEUM OF FLIGHT FOUNDATION Pay Method: CREDIT CARD 06639J Printed: Friday, July 31, 2015 10:07 AM 1 of 1 CIF I SYSTEMS 174111 INSPECTION RECORD INSP N NoRetain a copy with permit PERMIT NO. 145",-o6gq CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 981 Permit Inspection Request Line (206) 438-9350 elAp �_�206)�31-SE Pro e'cPt:( eVaik 0 e'ril (Cr It 7 Type f Inspectio lit at.q., t 1dries�: "� '�Q IniG(, " `l Date Called: r Special Instructions /vl��N Date anted ` a.m. p.m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. COMMENTS: r---- C "--c3 kg ( Inspector: Erc Date n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188, ,-.. (206) 431-4670 Permit Inspection Request Line (206) 438-9350 15--d0cR Pro eqt: (p Q �' N K- 7 V 7 Tyyp of Inspection: J 1 + �O 1,..., " t Ad rg s %.,(4 ice( Date Called �. u �. Instructions: 4/4 Dafe �e lb a.m.Special p.m. Re 0 in Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: AIM UCA— ern e� A J ( A Ake —a% e-c( Inspector: Dater -2_2__/, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER fif/4--0.17.451 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 7zPM-7/./1./�4/ Type of Inspection: Address: ' Suite #: 9:,z'y 6 i7 i./5 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 Inspector: _,.,_,__,i 4ffc-3 Date: a_'�// 4 Hrs.: / • 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SYMBOL LIST SYMBOL ABBV. DESCRIPTION SYMBOL ABBV. DESCRIPTION ODUCT SECTION - SUPPLY 0 TSTAT THERMOSTAT ODUCT SECTION - RETURN © S SMOKE DETECTOR 20x12 RECTANGULAR DUCT (INSIDE DIMENSION) COP COEFFICIENT OF PERFORMANCE ROUND DUCT ELECT. ELECTRICAL �% 12"o d EC ELECTRICAL CONTRACTOR 20x 2 SL SOUND LINED DUCT (INSIDE DIMENSION) EER ENERGY EFFICIENCY RATING n rls I ADJUSTABLE AIR EXTRACTOR EFF EFFICIENCY/EFFICIENT . I..1_J TURNING VANE GC GENERAL CONTRACTOR VD VOLUME DAMPER HSPF HEATING SEASONAL PERFORMANCE FACTOR —QM MD MOTORIZED DAMPER I.E. INVERT ELEVATION —0 BDD BACKDRAFT DAMPER IPLV INTEGRATED PART LOAD VALUE SD DUCT SMOKE DETECTOR MC MECHANICAL CONTRACTOR i SEPAL; 1 = (WIT MECH. MECHANICAL REQUIE_ r V LV^• .:::‘,:cat -OR. a/}a�� OFCI POC TYP. OWNER FURNISHED, CONTRACTOR INSTALLED POINT OF CONNECTION TYPICAL r `"� U.O.N. UNLESS OTHERWISE NOTED '.. In� P,pr� Mir EQUIPMENT TAG FLAG NOTE la+y I cPJ UU % • a i I (;1 • ?=`.lf� Ale .. DRAWING INDEX SHEET DESCRIPTION M-.1 COVER SHEET M-.2 SCHEDULES & CALCULATIONS M-1 787 PORT SIDE ELEVATION M-2 AFT SECTION OF 787 FORWARD CARGO BAY PLAN VIEW M-3 AFT SECTION OF 787 FORWARD CARGO BAY PORT SIDE ELEVATION M-4 AFT SECTION OF 787 FORWARD CARGO BAY STARBOARD SIDE ELEVATION M-5 787 PLAN VIEW Mechanical Summary MECH-SUM2012 Washington State Energy Code Conplbnca Forms for Cbmmercbl Binding, hcUdhg R2 & R7 over 3 stales and all R1 Revised May 2015 GENERAL1 ES Project Info Project Address: MUSEUM OF FLIGHT 767 HEAT PUMP ACOITION Cute ,7r.11r 27, 2015 INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER I.B.C. REQUIREMENTS. PROVIDE ENGINEERED AND STAMPED DESIGN DRAWINGS IF REQUIRED BY IBC. CONTRACTOR TO CONTACT OR HIRE A STRUCTURAL ENGINEER TO DETERMINE BUILDING AND SYSTEM IMPORTANCE FACTORS. UTILIZE ISAT OR OTHER SEISMIC BRACING COMPANY. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. MAJOR APPLICABLE CODES: 9404 EAST MARGINAL WAY For Bottling Dept. Use TttIMALLA WA Applcant tame: CNRS vnaOHT- RICE GROUP, INC Applcant Address: 20201 CEDAR VALLEY ROAD, LYNfrv004 WA AppisantPhone: 206-649-2454 Project Description Briebydescribe mechenbMsyste.. in the text box provided ❑Total Bldg PerformanceECONOMIZERS Total Bldg Perlormencecompllanoe Includes all mandatory prorlsbooper C401.20Pt/on2Only MECH-SLM and MECH-CHxfomu requiredLS ❑ New Building ❑ IiWBhg Add3bn 0 System Upgrade ❑ No System Charges THEADDITION OF AN 8TON HEAT PUNS, AND BOOSTER FAN. THIS IS A REDUNDANT HEATING/COOLING SYSTEM THE EXISTING HEATING/COOLING OF THE AIRCRAFT TO REMNN. CAN NOT BE USED: THERE IS NO PATHWAY TO ALLOW OUTISDE AIR INTO THE AIRCRAFT WITHOUT DAMAGING THE PLANE ITSELF. FANSYS DOC IS NOT PROVIDED AS THE FAN ENERGY WILL NOT COMPLY SINCE WE ARE USING THE HIGH PRESSURE DUCT OF THE EXISTING AIRCRAFT AND REQUIRE A LARGE FAN TO OVERCOME THE STATIC PRESSURE REQUIRMENTS. PLEASE BE AWARE THAT THE PLANE IS A MUSEUM ARTIFACT AND THE PRESERVATION OF THE PLANE FAR MORE IMPORTANT THAN THE ENERGY USE. IEER AND COP FAR EXCEED CODE RFOUIRFNFNTS 2012 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS 2012 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS 2012 WASHINGTON STATE ENERGY CODE Mechanical Systems Summary Equip D Type of System (Note 1) Space(s) Served Compton* Path Healhg and Cookie Fan Row Controls Air Fsononazr (Note 2) Ventietbn (Note 3) Energy Recovery GENERAL MATERIAL NOTES HP-1 HEAT PUMP 787 PASSENGER COMP Simple s `gisstzonecool Sleeting cooling d Constant volume (CV) Natural ventilation en ilatioC 2 per Not Applicable ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL PER SMACNA STANDARDS, IMC 603-4. ALL FLEXIBLE DUCTWORK SHALL BE PER NFPA 90A, UL 181, CLASS 1, 2-PLY VINYL FILM SUPPORTED BY HELICALLY WOUND, SPRING -STEEL WIRE; FIBROUS -GLASS INSULATION; POLYETHYLENE VAPOR -BARRIER FILM WITH MAXIMUM 6 FEET LENGTH. SOUND LINED DUCT SHALL BE FIBERGLASS, 1-1/2# DENSITY, 1" THICK WITH A MINIMUM NOISE REDUCTION COEFFICIENT OF 0.8. CONDENSATE PIPING SHALL BE TYPE "L" COPPER WITH PROPRESS FITTINGS. REFRIGERANT PIPE SHALL BE COPPER ACR TUBING WITH BRAZED AND FLAIR FITTINGS. Note f- Provide basic Wa description r m Mpt ya type, for example, uniteryrooftop air handler bull -up centre/ air handler; ahg '-packaged, spl9systemorpackaged terminal air cond/tbnerrheetpump: un/theater. warm-eirfurnace, a/*cob rests rroeheater, 4-13 pe tan coil VRF system, energy recoveryeirhandler. make-up eir system, ground or water -source Met pump, etc. Note2- If taking an exception to air economizer, aelotexceptbn taken from drop down menu and complet.MECH-ECONQ form. Summarydern/rions Meech exception re listed In MECH-ECOND. Note S- If ventilation *Notapplicabie is selected, provide explemebn in ProfectDescripilon box above. HVAC Hydronic Systems ❑ Hydronk ch3ed w Mar ❑Water-loopheet pump Q No hy4ronk systems 0 Hydronk hooting ❑ Geothermal Service Water Heating Systems Equipment Type (s) ❑ Not w star heatingtank(s) ❑ nstantaneous Q No servicewatersyatans ❑ Dedicated bolet❑ Heat exchange from apaceheatbolerr central hot water/steam Dktrbutlon Type (s) ❑ Circulation System 0 On -demand 1a ��[",/ Y 7E Y tS!ONS II (L� (��,-�•;�— -- I No of wogs 9 c1�(r�ss —r7Q to the SCO, a "• r o A ^"1provaI r�,7 E"_ Ultt�,a ^ of '�ilCl %�'• �III�. ' 1,..777 P^Visions t 3 I r ��f. plan su' Mau Irinit11411 Are .1..s..:www Mechanical Schedules ❑� Mechanical Fens ❑ h£CH.1, Form Indicate location olaqu/pmenlcompllax. Inlonnatlm. I1provided onplane then MECH-EQ forms aro not required, nomnr, Include on piens all applicabNCompeance information/MMWIn MECH-EQtables. Desi Load Calculations Q Load calculation summary ❑MECH-LOAD-CALC Form 0 Equipment retrofltr repair Provid•design loadca/culrbns/ran mechNpisystems andequ/pment serving the bulltl/ngheating, cooling or wnb4//ngn'ads.BabadcelcuetlensummerybprovosdwAhihepermrdotumenbHurtIncludesalapplkebie comp6nce hfametfon Menthe M3]LLWD-CA LC formic not requretl. loads in spr•(s)served hewmtcMngetlhom original design cam/Mona are nrrequindfoprrlrmlwdcrcu4flo15. cam/ onaEquipmentare notanuiredtpenbr whendesign calculation. COCA E Tra a)o l S- 0o Ran ratzi mazcl io ca to crz cnd oiiiicc . Approve! of anlatttitu30 r r not autPtc izo hie v4115103 ercriAatza C 3c2t3 do/wolf-4 Fitz! % j .. 1'l,. ley: ...... �.� Dote: I City of Tukwila BUILDRG DIVISIC Me -1 u , •. 2 2012 Washington Slab Energy Cade Conplence Fans for Qrnasrcbl Buildrlgs Including R2 & R3 over 3 stones and rd R1 AIRCRAFT FOR THIS PROJECT MECH-SUM Revved May 2015 Fan Power Ar syetemexceedhg5lp Q No arsystemaxceeds 5rp ()Clear Pro44• a MECH-FANSYSIcrmloreachHVAC system having a total fan systemmotarsmeplate horsepower reeedi g5horspewer. Refer to Section C4052.10and A€CH-FANSYS-DOCforrequlremaraserdexcepdono Commissioning Exception Summary Describe meals of r/g16rty ter conmlasbnlrg excptbn (cp.cky eta) forr/ systems noted as taking exception in Mechanical Systems Summery table. Refer to Section C408.2emi C408.4 for exception. ❑ Connessonlg w EbeprovIded fa al pplcable syalene Cbmrbsbarg Fxceptbm. ❑ Mechanical system(*) ❑ Srvkew atr Mating systm(s) For systems requiring conenissionhg, F/gur0C408.1.2.1 CammIssbnhgCoopl*nce CneUQstsheer be submetedtothe code official uµnprgectrormation SITE PLAN PLAN NORTH aD Low Energy and Semi -Heated Spaces (tote 6 and 7) Space Type Location In Ran(s) Space(s) Served Anse Served, stare fest Hererg Oepecb. BUM (Mae 4) Cooling Capecey. Btu1 (Note S) Peek Specs Condlonhg Opacity. Bhm-ef Cbnplence Chock Notes Note 4-Provide total Insulted heating ocaµfcpaclyofsystems srHgLowEnergyrSemi— s ( ftu Note 5- Provide total lmhlledcoolgcepectyolsyst.oserving La1Enrgyapece(a) in& NaWt If�G��•�.e�� Note 6-Refer to Section C101.52LowEnegy&/lding. lrtrladpeakaprecondsbl/rgc heat* nq(y�vcl�ltlk`ja`0+,yc��[{jIr�j0r. fffV,(((a1 wr\fa��a(y� NaY7-NaKMcrabb M.nngend�mrb Ting *lip!• the sransuNim.uePr tYn t�M9{.'li 4 TAN�lL CORRECTION! AUG 282015 City of Tukwila LISUILDING DIVISION Parcel 332404-9019 Number Name MUSEUM OF FLIGHT FOUNDATION H Site Address 111 9404 EAST MARGINAL WAY S 98108 rTHAT POR OF THE SE OTR OF SEC 33 TWP 24 N RNG 4 E WM IN KING COUNTY WA DESCRIBED AS FOLLOWS COMMENCING AT THE SE COR OF SD SUBD TH N 88-04 53 W A DIST OF 1314 13 FT ALG S LN THOF TO NELY MGN OF E MARGINAL WY S AND POB TH ALG SD MGN N 88-04-53 W A DIST OF 37.35 FT TH CONT ALG SD MGN N 22- 31-55 W A DIST OF 997 62 FT TH DEPARTING SD Legal MGN S 87-49-39 E A DIST OF 77-07 FT TH N 22-49-02 W A DIST OF 23.50 FT TH S 87-49-39 E A DIST OF 89.83 FT TH S 02-11- 39 W A DIST OF 42 19 FT TH S 88- 43-46 E A DIST OF 290.49 FT TH S-28- 43-46 E A DIST OF 89.25 FT TH S 88-18-47 E A DIST OF 164.78 Fi TO A LN THAT IS 500 FT FR AND PLW C/L RUNWAY 13R-31L TH ALG SD LN S 28-43-34 E A DIST OF 658.80 FT TH S 67-28-05 VV DIST OF 596 64 FT TO POB PER CITY OF TUK BLA NO L 02-058 REC #20030115900002 RECEIVED CITY OF TUKWILA AIJG 2 4 an'; MUSEUM OF FLIGHT 787 HE,stallFt§10thM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07/28/2015 REVISED: #2 - ADDED WET STAMP 08 /20 / 2015 COVER SHEET LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET M—.1 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total ==> Internal Loads Lights People Misc Sub Total ==> Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov/Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Zone Checksums By RICE Group Cabin Area COOLING COIL PEAK Peaked at Time: Mo/Hr: 7 / 18 Outside Air: OADB/WB/HR: 76 / 60 / 53 Space Sens. + Lat. Btu/h 0 0 1,766 12,121 181 51,703 0 0 0 81 65,851 2,852 10,800 0 13,652 0 0 0 0 Grand Total =_> 79,502 Plenum Sens. + Lat Btu/ Net Percent Total Of Total Btu/h (%) O 0 O 0 1,766 2 12,121 15 181 0 51,703 64 O 0 O 0 0 0 0 81 0 0 65,851 82 0 2,852 0 10,800 0 0 0 13,652 17 0 0 0 0 0 0 0 686 0 0 0 0 0 0 0 0 0 0 80,188 4 13 0 0 0 0 0 0 0 0 0 0 100.00 CLG SPACE PEAK Mo/Hr: 7 / 18 I OADB: 76 Space Percent I Sensible Of Total Btu/h (%) O 0 O 0 1,766 12,121 181 51,703 0 0 0 113 65,883 2,852 6,000 0 8,852 2 16 0 69 0 0 0 0 88 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total ==> Internal Loads 4 Lights 8 People 0 Misc 12 Sub Total =_> HEATING COIL PEAK Mo/Hr: Heating Design OADB: 26 O 0 Ceiling Load O 0 Ventilation Load 0 0 Adj Air Trans Heat Ov/Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 74,734 100.00 Grand Total =_> Space Peak Space Sens Btu/h 0 0 -1,520 0 -1,581 -34,628 0 0 0 -1,212 -38,940 0 0 0 0 0 0 0 -27,002 -65,942 Coil Peak Percent Tot Sens Of Total Btu/h (%) 0 0 -1,520 0 -1,581 -34,628 0 0 0 -1,212 -38,940 0.00 0.00 3.08 0.00 3.21 70.30 0.00 0.00 0.00 2.46 79.05 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 -10,318 20.95 O 0 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 -49,259 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F gr/Ib 6.7 80.2 75.7 0.0 0.0 0.0 0.0 0.0 0.0 6.7 80.2 4,001 72.2 59.1 55.0 O 0.0 0.0 0.0 O 0.0 0.0 0.0 Leave DB/WB/HR °F °F gr/Ib 55.0 51.8 53.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: Boeing 787.trc AREAS Gross Total Glass ft2 (%) Floor Part Int Door ExFIr Roof Wall Ext Door 557 0 0 0 557 0 0 2,388 117 5 0 0 % OA cfmlft' cfm/ton ft'/ton Btu/hr•ft' No. People Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups TEMPERATURES SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict Cooling 55.0 72.0 72.0 72.2 0.0 0.0 0.0 Heating 85.0 70.0 70.0 67.7 0.0 0.0 0.0 AIRFLOWS Cooling 4,001 4,001 4,001 0 213 213 25 0 4,026 238 0 0 0 0 Heating 4,001 4,001 4,001 0 213 213 25 0 4,026 238 0 0 0 0 ENGINEERING CKS Cooling Heating 5.3 5.3 7.18 7.18 598.71 83.35 143.96 -88.44 24 HEATING COIL SELECTION CapacityColl Airflow Ent Lvg MBh cfm °F °F Main Htg -49.3 4,001 67.7 78.9 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -49.3 TRACE® 700 v6.3.1 calculated at 01:42 PM on 07/27/2015 Alternative - 1 System Checksums Report Page 1 of 1 FAN SCHEDULE EQUIP. TAG AREA SERVED MFG' / MODEL NUMBER CFM RPM E.S.P. INCHES W.G. FAN MOTOR NOISE Dba DRIVE DISCONNECT CONFIGURATION WEIGHT LBS. REMARKS HP VOLTS PH. BF-1 BOOSTER FAN TWIN CITY MPLQS-165 4200 3400 11 15 460 3 86 DIRECT BY ELECTRICAL INLINE 501 1, 2, 3, 4, 5, 6 NOTES: 1. PROVIDE WITH VFD. 2. INTERLOCK WITH HP-1. 3. DUCT CONNECTS TO FAN WITH APPROVED FLEXIBLE CONNECTORS. 4. MOUNT FANS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND CLEARANCES. 5. CLASS 3 CONSTRUCTION. 6. COORDINATE EXACT SPEED OF FAN WITH DUCTLESS SPLIT TO PREVENT MOISTURE CARRY OVER. VENTILATION CALCULATION NATURAL VENTILATION IS PROVIDED PER 1203.4 OF THE IBC. OPERABLE AREA OF THE DOORS IS 42.68 SF. THE OCCUPIABLE AREA OF THE AIRCARFT IS 557 SF. 42.88 SF/557SF= 7.6% OPERABLE AREA. THIS EXCEEDS CODE REQUIREMENT OF 4% STRUCTURAL CALCULATIONS EQUIPMENT LOCATED IN CARGO BAY WHICH 15 DESIGNED TO CARRY LOADS IN EXESS OF 1000 LBS. THE CONDENSING UNIT IS LOCATED ON THE TARMAC AND IS 620 LBS. ENERGY CODE NOTE THE WASHINGTON STATE ENERGY CODE IS INTEND TO REGULATE THE DESIGN AND CONSTRUCTION OF BUILDINGS (WSEC 101.3). THIS PROJECT INVOLVES PROVIDING TEMPORARY, REDUNDANT AND REMOVABLE AIR CONDITIONING TO AN EXISTING AIRCRAFT. AS SUCH, MANY PROVISONS OF THE ENERGY CODE ARE DIFFICULT OR IMPOSSIBLE TO APPLY. WE HAVE DESIGNED THE SYSTEM WITHOUT AN ECONOMIZER PER SECTION 403.3.1 AS THE AIRCRAFT IS MUSEUM ARTIFACT AND ADDING A LOUVER TO THE EXTERIOR SKIN OF THE AIRCRAFT WILL DESTROY A PORTION OF THE PLANE. WE FEEL THIS IS JUSTIFIED SINCE THE IEER AND COP OF THE SELECTED COOLING/HEATING EQUIPMENT IS FAR IN EXCESS OF THE WSEC EFFICIENCY REQUIREMENTS (22.7 AND 4.0 RESPECTIVELY) WE ARE REQUESTING THE CITY WANE THE ECONOMIZER REQUIREMENT FOR THE FOLLOWING REASONS: 1) ENERGY EFFICIENCY OF THE EQUIPMENT IS FAR IN EXCESS OF CODE REQUIREMENTS FOR BOTH HEATING AND COOLING. 2) THE ADDITION OF AN OUTSIDE AIR INTAKE TO THE AIRCRAFT WOULD RUIN THE VALUE OF THE PLANE AS A MUSEUM ARTIFACT 3) THE WSEC IS INTENDED FOR BUILDINGS AND DOES NOT DIRECTLY REGULATE THE ENERGY USE OF AIRCRAFT. DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE ' EQUIP. TAG AREA SERVED OUTDOOR CONDENSING UNfT INDOOR AIR HANDLER MFG' / MODEL NUMBER NOMINAL TON COOL CAP. MBH HEAT CAP. WEIGHT LBS NOISE DBA IEER ELEC. REQ. EQUIP. TAG MFG' / MODEL NUMBER AIRFLOW CFM ELEC. REQ. WEIGHT LBS REMARKS TOTAL SENS. TOTAL MBH COP MCA VOLTS PH. MCA VOLTS PH. CU-1 OFFICE 109 DAIKIN RXYQ96TYDN 8.0 96.0 73.92 108.0 4.0 620 50 22.7 20.6 460 3 AHU-1 DAIKIN FXMQ96MVJU 3000 10.7 208/230 1 150 1,2,4,5 NOTES: 1. PROVIDE WIRELESS REMOTE CONTROLLER 2. INSTALL UNIT INDOOR UNIT IN CARGO BAY 3. NOT USED. 4. NO ECONOMIZER PROVIDED. THIS PLANE IS A MUSEUM ARTIFACT AND THERE IS NO POSSIBLITY FOR LOCATING THE OUTSIDE AIR DUCT OR RELIEF DUCT. 5. PROVIDE CONDENSATE PUMP WfTH UNIT AND PUMP CONDENSATE TO APPORVED DRAIN. I REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 8 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 4 2C5 MUSEUM OF FLIGHT 787 HEAT PUMP SYSTEM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07 /28 / 2015 REVISED: #2 - ADDED WET STAMP 08 /20 / 2015 • SCHEDULES & CALCULATIONS LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET M-,2 000000i AIR FILTER SECTION DOORS TO STAY OPEN DURING VIEWING TO PROVIDE NATURAL VENTILATION 00 00000000000000000 8 TON HEAT PUMP AHU PRESSURE BOOSTER FAN O• HEAT PUMP OUTDOOR UNIT CONNECTIONS TO AIRCRAFT SUPPLY AIR SYSTEM PORT SIDE ELEVATION Scale: 1 = 140 DOORS TO STAY OPEN DURING VIEWING TO PROVIDE NATURAL VENTILATION 000000 0000 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 282015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 4 2C s5 PERMIT CENTER MUSEUM OF FLIGHT 787 HEAT PUMP SYSTEM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07 /28 / 2015 REVISED: 82 - ADDED WET STAMP 08 /20 / 2015 787 PORT SIDE ELEVATION LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET " p —1 ELECTRICAL ENCLOSURE 42" CLEAR CONNECT TO CONDENSATE PUMP SPACING OF COPPER 42" CLEAR MIN. REFRIGERANT LINE SUPPORTS SHALL NOT EXCEED 5'-0" EXISTING CARGO SUPPORT RAILS MIN. WITH INTEGRATED ROLLERS AND HOLOoowNs (TYP) a CONNECT TO EXISTING AIRCRAF-SUPPLY DUCT TYPE ACR COPPER REFRIGERANT LINES DAIKIN DACA-MQ96M-13-1K DMERV13AIKIN i •` DOUBLE BRAIDED TYPE T316L ROUTE STAINLESS FLEX LINES AIR FILTER &CABINET STAINLESS STEEL REFRIGERANT THROUGH EXISTING AIRCRAFT DUC' `� TWIN CITY MPLQS-165 MODULAR PLENUM FAN LINES WITH T316L FITTINGS AND GROUND AIR CONNECTION TO 3[ ■_ (�1 OUTDOOR HEAT PUMP UNIT REFRIGERANT LI CONNECTION POINTS r (ff o AIRFLOW 2542 CFM Q m1 0 XI 1 1 DUCT MOUNTED SMOKE/DETECTOR 1 1 1 \ WITH AUDIBLE AND VISUAL ALAR 1 • PROCO SERIES 500 STYLE 530 20" 0 o . RUBBER DUCT EXPANSION JOINT NEOPRENE SHOCK AND VIBRATION ABSORBING SUPPORT (TYPICAL) MDO SUPPORT SKID UTILIZE CARGO BAY FLOOR LATCHES FOR RESTRAINT DAIKIN FXMQ96MVJU HEAT PUMP INDOOR UNIT MDO SUPPORT SKID UTILIZE CARGO BAY FLOOR LATCHES FOR RESTRAINT a CONNECT TO EXISTING AIRCRAFT SUPPLY DUCT VHEF wA, RECEIVED A.�G' CITY nr TI IIICWI! A e� �oF FORWARD CARGO BAY PLAN VIEW Scale: 1 = 20 PLAN NORTH r- REVIEWED FOR ODE COMPLIANCE APPROVED AUG 28 2015 City of Tukwila BUILDING DIVISION MIS 009'f AUG 2 4 2015 PERMIT CENTER AIRFLOW AIRFLOW MUSEUM OF FLIGHT 787 HEAT PUMP SYSTEM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07 /28/ 2015 REVISED: #2 - ADDED WET STAMP 08 /20 / 2015 AFT SECTION OF 787 FORWARD CARGO BAY - PLAN VIEW LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET M-2 AIRFLOW -- DUCT MOUNTED SMOKE/DETECTOR WITH AUDIBLE AND VISUAL ALAR EXISTING CARGO SUPPORT RAILS WITH INTEGRATED ROLLERS AND HOLD-DOWNS (TYP) jjjDAIKIN DACA-MQ96M-13-1K / MERV13 AIR FILTER & CABINET !// KIT CARGO BAY CEILING DAIKIN FXMQ96MVJU HEAT PUMP INDOOR UNIT COOLING CAPACITY 96000 BTU/H HEATING CAPACITY 108000 BTU/H 208V 10 8.6 FLA (10.7 MCA) 2542 CFM @ 0.95" H2O GQ. I� TWIN CITY MPLQS-165 MODULAR PLENUM FAN 15 HP, 3600 RPM, 460V 30, 4200 CFM @ 11.0" H2O MODULATE SPEED TO MAINTAIN 0.0" H2O PRESSURE (+/- 0.1") AT MODULAR PLENUM FAN INLET. FAN OUTLET PRESSURE LIMITED TO 12" H2O. SPEED REGULATION GOVERNED BY SIEMENS PXC CONTROLLER AND ABB VFD 24 GAUGE GALVANIZED STEEL DUCT SETRA 264 STATIC PRESSURE SENSOR +/- 2.5" H2O IIL EXISTING RETRACTABLE CARGO HOLD-DOWN v I (TYP) MDO SUPPORT SKID UTILIZE CARGO BAY FLOOR LATCHES FOR RESTRAINT PORT SIDE ELEVATION Scale: 1 = 20 v 1 11 ROUND BOLTED FLANGE CONNECTOR 18 GAUGE GALVANIZED STEEL DUCT SETRA 264 STATIC PRESSURE SENSOR 0-15" H2O NEOPRENE SHOCK AND VIBRATION ABSORBING SUPPORT (TYPICAL) MDO SUPPORT SKID UTILIZE CARGO BAY FLOOR LATCHES FOR RESTRAINT REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 8 2015 City of Tukwila BUILDING DIVISION N(5 oo9� 9 CONNECT TO EXISTING AIRCRAFT SUPPLY DUCT PROCO SERIES 500 STYLE 530 20" 0 RUBBER DUCT EXPANSION JOINT 20" 0 20" 0 SQUARE TO ROUND ADAPTOR 20" 0 RECEIVED CITY OF TUKWILA AUG 2 4 2C5 PERMIT CENTER 20" 0 MUSEUM OF FLIGHT 787 HEAT PUMP SYSTEM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07128/2015 REVISED: #2 - ADDED WET STAMP 08 /20 / 2015 AFT SECTION OF 787 FORWARD CARGO BAY PORT SIDE ELEVATION LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET M-3 20" 0 METRAFLEX DOUBLE BRAIDED TYPE T316L STAINLESS STEEL REFRIGERANT LINES OR EQUIVALENT 850 PSI MINIMUM RATED WORKING PRESSURE @ 70° F ROUTE STAINLESS STEEL REFRIGERANT CONNECT • EXISTING AIRCRAFT SUPPLY DUCT 20" 0 20" 0 RUBBER DUCT EXPANSION JOINT ROUND BOLTED FLANGE CONNECTOR FLEX LINES, LIQUID -TIGHT ELECTRICAL CONDUITS, AND DRAIN TUBING THROUGH / `\ EXISTING AIRCRAFT FIBERGLASS DUCT / `1/2" OD TYPE L COPPER AND GROUND AIR CONNECTION PORT 3/8" ID FLEXIBLE VINYL TUBING 20" 0 1-1/4" ID-� ISULATE VAPOR LINE /ITH ELASTOMERIC LOSED CELL PIPE ISULATION. MINIMUM /ALL THICKNESS = 3/4" EXTEND CONDENSATE )RAIN TUBING TO EXISTING TRENCH DRAIN - SMOKE DETECTOR PROVIDES SIGNAL TO LOCAL AUTOMATION PANEL TO PROVIDE SYSTEM SHUTDOWN -MAXIMUM AIRFLOW 2542 CFM TUBING SUPPORTS (TYP) _71 SQUARE TO ROUND ADAPTOR 1 1 TWIN CITY MPLQS-165 MODULAR JMFAN s�us uui ABB ACH550 VFD 49� STRUT SUPPORT ASSEMBLY BRACE AS REQURIED CARGO BAY CEILING REMOVE A MINIMUM OF 32 SQUARE FEET OF CEILING PANELS TO PROVIDE SUFFICIENT RETURN AIR VOLUME FROM PASSENGER DECK TO FORWARD CARGO BAY INSULATE ALL SHEET METAL DUCTWORK AND FAN ENLOSURES DOWNSTREAM OF DAIKIN INDOOR AHU WITH OWENS CORNING SOFTR TYPE 100 DUCT WRAP OR EQUIVALENT. INSULATION SHALL PROVIDE AN INSTALLED RATING OF R6.0 AT AN INSTALLED THICKNESS OF 1-1/2". ALL INSULATION SEAMS SHALL BE SEALED WITH UL 181 MYLAR TAPE. INSULATION FACING SHALL HAVE A FLAME SPREAD INDEX OF 25 OR LESS AND A SMOKE DEVELOPED INDEX OF 50 OR LESS 7 1-1/8" OD TYPE ACR COPPER VAPOR LINE. INSULAT WITH ELASTOMERIC CLOSED CELL PIPE INSULATION WITH 3/4" WALL THICKNESS R 4.3 MEETING REQUIREMENTS OF NFPA 4.3.3.1 1/2" OD TYPE ACR COPPER LIQUID LINE 1/2" OD TYPE L COPPER CONDENSATE DRAIN LINE EXISTING RETRACTABLE CARGO HOLD-DOWN (TYP) /-DAIKIN FXMQ96MVJU HEAT PUMP INDOOR UNIT DAIKINDAC M-13-1K MERV13 AIR FILTER & CABINET -1/2"OD TYPE COPPER `iI -- MAXIMUM AIRFLOW 2542 CFM DIVERSITECH CP-22 CONDENSATE PUMP 120 V 1.9A 10 60Hz 1.6 GPM 22 FEET HEAD CONNECT HIGH LEVEL ALARM CONTACTS TO SIEMENS PXC CONTROLLER TO PROVIDE AUTOMATIC SYSTEM SHUTDOWN FORWARD CARGO BAY FLOOR SMOKE DETECTOR PROVIDES SIGNAL TO LOCAL AUTOMATION PANEL TO PROVIDE SYSTEM SHUTDOWN GROUND AIR CONNECTION PORT INSTALL 1/4" MESH OR FINER SCREEN ID DAIKIN RXYQ96TYDN 8 TON VRV-IV HEAT PUMP UNIT IEER = 28.0 NON DUCTED / 22.7 DUCTED HEATING COP 4.6 NON DUCTED / 4.0 DUCTED 480V 60Hz 30 RATED LOAD AMPS (RLA) = 10.2 MINIMUM CIRCUIT AMPACITY (MCA) = 20.6 MAXIMUM OVERCURRENT PROTECTION (MOP) = 25.0 EXTEND STAINLESS STEEL FLEXIBLE REFRIGERANT LINES TO HEAT PUMP OUTDOOR UNIT SEE DETAIL M-4-1 FUSELAGE BELLY LINE 0 0 0 0 O o 0 0 1 J EXISTING AIRPORT RAMP ASPHALT PAVING BOLTHOLD SP10-38 ASPHALT ANCHOR (TYP) LOCATE OUTDOOR UNIT 11 -0 TO THE PORT SIDE OF AIRCRAFT CENTER LINE STRUT MOUNTED PIPE SUPPORT CLAMPS METRAFLEX DOUBLE BRAIDED TYPE T316L STAINLESS STEEL REFRIGERANT LINES OR EQUIVALENT 850 PSI MINIMUM RATED WORKING PRESSURE @ 70° F 1-1/4" ID BOLTHOLD SP10-38 ASPHALT ANCHOR (TYP) 0 /7/8" OD TYPE L ACR COPPER VAPOR LINE INSULATE WITH ELASTOMERIC CLOSED CELL PIPE INSULATION MINIMUM WALL THICKNESS = 3/" 3/8" OD TYPE L ACR COPPER LIQUID LINE SIGHT GLASS m STRUT SUPPORT RAIL t �. OUTDOOR UNIT REFRIGERANT PIPING CONNECTIONS & SUPPORT DETAIL M-4-1 STARBOARD SIDE ELEVATION Scale: 1 = 20 M(S-OO91 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 8 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 4 2015 PERMIT CENTER MUSEUM OF FLIGHT 787 HEAT PUMP SYSTEM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07 /28/2015 REVISED: #2 - ADDED WET STAMP 08 /20 / 2015 AFT SECTION OF 787 FORWARD CARGO BAY STARBOARD SIDE ELEVATION LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET M-4 ACCESSIBLE AREA DOOR FOR VENTILATION ( OCCUPIABLE AREA = 557 SQ. FT. ENTRY POINT W W REMOTE WALL MOUNTED WIRELESS CONTROLLER PLAN VIEW Scale: 1 = 140 PLAN NORTH tr4 DOOR EXIT POINT REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 8 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 4 2015 PERMIT CENTER MUSEUM OF FLIGHT 787 HEAT PUMP SYSTEM SYSTEM LOCATION: AIR PARK DRAWN BY: FENTON KRAFT REVISED: 07128/2015 REVISED: #2 - ADDED WET STAMP 08/20 / 2015 787 PLAN VIEW LOCATION OF PROJECT: 9404 EAST MARGINAL WAY SOUTH TUKWILA WASHINGTON 98108-4097 SHEET M-5 E787 Equipment and Control Com sTfinen Equipment RECEIVED CITY OF TUKWILA JUL 31 2015 PERMIT CENTER Quan Description Brand Model Rating 1 VRV-IV Heat Pump Unit (Outdoor unit) - 460V (variable refrigerant temp) Daikin RXYQ96TYDN 8 Ton 1 Split system heat pump indoor unit (AHU) - 208V (Air handler / coil) Daikin FXMQ96MVJU 8 Ton 1 Navigation Remote Controller II (72) (In cabin sensor and controller) Daikin BRC1E72 N/A 1 BRC1 E72 Face Decal (Mode, Fan and Dual Setpoints) Daikin BRC1 E72RMF2 N/A 1 MERV 13 Filter Kit (Air filter housing an filter assembly for AHU) Daikin DACA-MQ96M131 K N/A 1 Interface for use in BACnet® (provides Zink with Siemens controls etc.) Daikin DMS502B71 N/A 1 Group Control Adaptor PCB Daikin KRP4A71 N/A 1 I -Touch Manager (controller, programmer, web interface for heat pump) Daikin DCM601A71 N/A 1 Pressure booster blower (boosts supply air pressure to aircraft ) (15hp) Twin City Blower MPLQS 4400 cfm 1 Variable frequency drive (provides power & controls blower speed) ABB ACH550-UH-023A-4 15 hp 1 Condensate Pump Becket BEC CB251UL 25 ft hd 1 Duct smoke detector (with digital output to signal automated shutdown) System Sensor SYS-D4120 N/A 1 Three foot sampling tube (duct sensor for smoke detector) System Sensor SYS_DST3 N/A 1 Stainless steel corrugated liquid refrigerant line with fitting ends Metraflex price & size pending 1 Stainless steel corrugated vapor refrigerant line with fitting ends Metraflex price & size pending 2 Unions for refrigerant lines 1 Sight Glass / Moisture Indicator Emerson HMI-1TT4 1 Bi-Directional Filter Dryer (1/2" sweat) Emerson BFK164S 2 Isolation Valves for refrigerant lines (vapor) Mueller BV 11/8 ODS 2 Isolation Valves for refrigerant lines (liquid) Mueller BV 1/2 ODS 1 25 lb cylinder R-410a refrigerant Various 1 Ductwork (connecting AHU to pressure booster blower) in design 1 Ductwork (pressure booster blower to aircraft ductwork) in design 1 Flexible hose (for vibration isolation of pressure fan to A/C) price & size pending 1 Condensate discharge tubing and flex line (3/8" ID)100' Mars 79132 1 3 pole disconnect fused disconnect for outdoor heat pump unit Square D 1 Vibration aborbers Design Complete 1 Unistrut and strut fittings (for anti vibration support frame) awaiting design 1 Equipment skids awaiting design Controls REVIEWED FOR CODE COMPLIANCE APPROVED Quan I Description AUG 9 Fl 7015 Brand Model ( Rating 1 ALN Level Controller with TCP/IP, FLN,RS485,P2, ' Siemens PXC36-PEF.A 36 point 1 Controller Enclosure with hinged cover city of Tukwila Siemens PXA-ENC19 19" 1 Siemens Power Supply / 120V Outlet Assy � �` DIVISION �;O4LQ!.. I..� Siemens PXA-SB115V192VA 192VA 1 8 Switch HOA (accessory) iemens PXA8-M 1 FLN Licence (needed for FLN control of freq drive) Siemens LSM-FLN36.A 2 Duct Temperature Sensor (Platinum RTD) Siemens 544-339-8 1 Temp, RH room sensor (price needs revision downward) Siemens 1 Static pressure sensor +/- 2.5" H2O (between AHU and booster fan) Setra C-264 1 Static pressure sensor 0-15" H2O (booster fan discharge) Setra C-264 1 Current Sensor (for Outdoor Unit monitoring and trending) TBD TBD AC absolute comfort Job Name: Location: Purchaser: Engineer: Submitted To: Submitted By: For: ❑ Reference ❑ Approval ❑ Construction Date: Unit Designation: Schedule #: Model No.: FEATURES/BENEFITS • Integrate Daikin VRV, SkyAir and Duct -Free Split Systems with third party building automation systems supporting the BACnet protocol. • BACnet Application Specific Controller (B-ASC) device profile compatible with BACnet (ANSI / ASHRAE-135) • BACnet IP Data Link Layer (Annex J) • Supports COV — Change of Value, Property Array Index and Segmented Requests • IPV6 and Foreign Device Registration capability • BTL Certification (Operating System Version 6.2 and Later) Power: Power supply (externally supplied) Power consumption Operating conditions: Surrounding temperature Storage temperature Humidity (% Relative) Dimensions (H x Wx D) 24VAC, 50/60Hz 20 Watts maximum (40 VA Transformer Recommended) 14° F to 122° F 5°Fto140°F 0% to 98% (non -condensing) 10-13/16"x 10-11/32" x 2-11/16" Maximum number of outdoor units Maximum number of indoor units Temperature Unit 20 (40 with DAM411851) 256 (512 with DAM411851) Degrees Fahrenheit or Celsius Connectivity: DIII-Net x 2 10BASE-T Di (Digital I Do (Digital Output) x4PPROVEQ A/C r 10( E I tQh)E COMPLtA communication line to BACnet network Forced Off Function alfunction indication Options: DAM411 B5' Certificatio AUG ;) 8 2015 Alids (2) DIII-Net lines F C ftyy of Tukwl a Part WiltbrikZvmsteN 5 Subpart B Class A RECE.NED CITY OF TUKWILA JUL 3 1 2015 PERMIT CENTER SPECIFICATIONS OF COMMUNICATIONS CABLING (DIII-NET) TYPE 2-conductor, stranded, non -shielded copper cable / PVC or vinyl jacket SIZE AWG18-2 TOTAL LENGTH Maximum wiring distance between units: 3,280 ft Maximum wiring length: 6,550 ft Daikin AC (Americas), Inc. ♦ 1645 Wallace Drive — Suite 110 • Carrollton, TX 75006 SDS DMS502B71 5-11 www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incumng any obligations) VDAIKIr�J AC absolute comfort Submittal Data: DMS502B71 BACnet® Interface Daikin indoor unit monitoring and control points accessible through the DMS502B71 Check the appropriate box indicating the required integrated points for this project. Monitoring points Function On / Off status Description Monitors the On / Off status of the indoor unit. Alarm Monitors whether or not the indoor unit is operating normally, and issues an alarm if the indoor unit has a malfunction. Malfunction code Displays a malfunction code specified by Daikin if an indoor unit in the system has a malfunction. Operation mode Monitors if the indoor unit is in Cool, Heat, Fan, or Dry mode. Room temperature (Note 1) Monitors and displays the room temperature. Filter sign Monitors filter run time and provides service alert. Thermo on Monitors whether or not the indoor unit is actively cooling or heating. Compressor status Monitors if the compressor of the outdoor unit connected to the indoor unit is properly operating. Indoor fan status Monitors if the indoor unit's fan is properly operating. Heater operation status Monitors if the indoor unit's heater is properly operating. Communication status Monitors the indoor unit's DIII-net communications status. Operation, configuration, and monitoring points On / Off stop operation (Note 2) Starts / stops the indoor unit and monitors the latest status. Operation mode setting (Note 2) Sets the Cool / Heat / Fan / Dry / Auto mode for the indoor unit and monitors the latest mode. Setpoint setting (Note 2) Sets the setpoint of the indoor unit and monitors the latest setpoint. Filter sign and reset Monitors the filter run time, provides service alert, and allows a manual reset of the status as required. Remote permit / prohibit (Note 2) Permits or prohibits the remote controller so that it can or cannot be used to control the indoor unit's On/Off / Operation mode / Setpoint. Lower Centralized Controller operation enable / disable Enables or disables operation of a Centralized Controller connected to the DIII network. Fan speed setting (Note 2) Sets the fan speed and monitors the latest setting. Vane direction setting (Note 2)' Sets the vane direction and monitors the the latest setting. The forced system stop command will force the indoor unit to stop running Forced system stop based upons a received emergency alarm input. Remote controllers will be locked out from restarting indoor units during the forced system stop event. Forced Thermo off In response to the forced thermo-off command, the indoor unit stops actively cooling or heating. Fnarnv cavinn Offsets the intemal setpoint +3.6°F (2°C)in cooling, and -3.6°F (-2°C) in heating in an indoor unit. The actual setpoint is not changed. Application Notes 1. Room temperature data (BACnet object name RoomTemp XX() by default is reported from the Daikin indoor units return air thermistor. This applies to all VRV indoor units styles and capacities. During periods when the indoor unit is turned off or during certain operating modes that cycle the fan off including defrost operation, hot -start and system pressure equalization, the reported temperature may not accurately reflect the actual space temperature. For applications where this temperature value will be primary to system control including mode and temperature setpoint management, it is recommended that the Daikin remote temperature sensor (Part No. KRCS01-1 B or 4B depending on model) is specified for each indoor unit and installed within the occupied space or unit be configured to be controlled from temperature sensor in BRC1 E71 Navigation Controller if the unit is capable. 2. The Daikin indoor unit maintains the settings for temperature, on / off status, operating mode, vane direction and fan speed in non-volatile memory each time they are changed. These settings will not be lost upon a power loss event. 3. BACnet® is a registered trademark of ASHRAE. Daikin AC (Americas), Inc. • 1645 Wallace Drive — Suite 110 • Carrollton, TX 75006 SDS DMS502871 5-11 www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) r DA/K/N AC ° absolute comfort Job Name: Purchaser: Engineer: Adapter: D KRP4A71 ❑ KRP4A72 ❑ KRP4A73 ❑ KRP4A74 Installation Kit: ❑ KRP4A93 ❑ KRPIB98 ❑ KRP1C93 ❑ KRP1B101 Submitted To: For: ❑ Reference ❑ Approval ❑ Construction Submitted By: Date: Unit Designation: Schedule #: Model No.: Location: FEATURES / BENEFITS • Applied to individual VRV indoor units to facilitate remote start / stop control and temperature setpoint for remote control groups and contact closure outputs for operation and malfunction status. • Low cost altemative to traditional energy management integration for small projects with simple control requirements. • Provides a simple contact closure input (configurable as momentary or constant contact) to remotely start and stop individual VRV indoor units or all indoor units in a remote controller group. • Provides normally open dry contact outputs for indication of indoor unit operation (on/off) status and malfunction status (normally open contact will close when the host indoor unit is in an alarm condition.) • Analog input provided for remote temperature setpoint adjustment (Centigrade values only) with a 0-135 Ohm signal. See note 2 below. IKRPIB Model Application FXSQ, FXMQ, FXAQ, FXNQ, FXLQ FXHQ, SkyAir FHQ FXFQ, FXZQ, SkyAir FCQ FXDQ :installationKit Requirements FXAQ FXFQ, SkyAir FCQ FXHQ, SkyAir FHQ FXDQ, FXZQ KRP4A71 KRP4A72 KRP4A73 KRP4A74 KRP4A93 Installation Box KRP1 B98 Installation Box KRP1C93 Installation Box KRP1B101 Installation Box Power Requirements PCB Power Supply Control Circuit Power Supply Contact Specifications B1-BC, B2-BC W1-W2 Allowable Current W3-W4 Allowable Current (A+) (A-) PCB Connections B1-B2-BC Non -voltage input only (A+) (A-) ; Analog 0-135 ohm input. Provided by host indoor unit Provided by others if required Input Only 10mA to 3A at 24VAC 10mA to 3A at 24VAC 0-135 Ohm W1-W2 t Operation status output / Dry contact W3-W4 ) Malfunction status output / Dry contact X18A Harness connection to VRV indoor unit PCB P1-P2 To indoor unit PCB P1-P2 terminals Wiring Schematic To Power Supply connector (X18A) on indoor unit PCB. To P1/P2 on indoor unit PCB. O 1I O operation output —roxy,-.97`7 W2 Error Output 24VAC W3 W4 LOo 0-135 ohm o— I Remote Set Point Remote Control Inputs Application Notes 1. Control mode selector switch (RS1) allows the installer to configure the start / stop priority between the adapter and operation button on the remote controller. 2. Non -linear Fahrenheit temperature setpoint equivalents to the standard Centigrade (1°C increments) control basis will result in various setpoint values being unavailable through the analog input. Daikin AC (Americas), Inc. • 1645 Wallace Drive — Suite 110 • Carrollton, TX 75006 SDS KRP4A71,72,73,74 05-09 www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incuning any obligations) 'DA/KIN AC absolute comfort Project Name: Submittal Data Sheet BRC1E72 - New Navigation Controller Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #: For use with the following VRV indoor unit models: FXAQ, FXDQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXSQ, FXTQ, FXZQ For use with the following Daikin SkyAir indoor unit models: FAQ, FBQ, FCQ, FHQ, FTQ Model BRC1E72 Description New Navigation Remote Controller Maximum Indoor Units 16 Communication Wire 18AWG 2, No polarity Stranded, Non -shielded Total Wiring Length 1,640 ft (500 m) Communication Protocol Daikin Proprietary P1P2 protocol Power 16VDC supplied by Indoor unit (1.58VA maximum) Comfort Setpoint Range 60 to 90°F (16 to 32 °C) Setback Setpoint Range 40 to 95 °F (5 to 35°C) Operating Temp Range 14 to 122°F (-10 to 50°C) Operating Humidity Range 75% or less (w/o condensation) Dimensions (WxHxD) 4.72x4.72x0.75 inch (120x120x19 mm) Weight (Mass) 0.42 lb (0.19 kg) Features / Benefits: • Up to 16 indoor units are controllable in one group • Can be combined with a secondary controller for dual operation 4-3/4"-� E- -{ 3/4" • Backlit LCD display in English, French, or Spanish • Temperature sensor with configurable offset • Display of Temperature and Setpoint in 1°F / °C increments • Three display modes Detailed, Standard and Simple • Dual setpoints (individual cooling and heating setpoints) with minimum setpoint differential or Single setpoint (occupied period) • Setpoint range limits for Cooling and Heating • Independent cool/heat setback setpoints (unoccupied period) • Auto changeover mode can automatically change to cool/heat mode at setpoint +/-1° F (can be configured from 1 to 4° F using field settings) with a guard timer for 15, 30, 60 or 90 min. Surely change at another+/-1° F (can be configured from 1 to 4° F using field settings) ignoring the guard timer. • Built in 7, 5+2, 5+1+1, and 1 (Everyday) schedule with up to 5 actions per day with independent cool/heat or setback setpoints • Automatic adjustment for Daylight Savings Time (DST) • 48 hour clock/calendar backup (in case of power failure) • Constantly monitors the system for malfunctions with immediate display of fault location and condition • Prohibit buttons on remote controller • Limit selectable operation modes • Display can be configured not to show setpoint when unit is Off. Display Off, instead of mode when unit is off. Fan speed display removable. • Backwards compatible 04 SYSTEM 1:7� r hr Sioci I:tl nntMOI ler hilt WNMtlOfn$o Mind IMAN Cool ra, g:ll Rom Sri to :A ° 74 '1st Ycrr d—rh, t.h• iIt ( un Daikin AC (Americas), Inc., 1645 Wallace Drive, Suite 110, Carrollton, TX 75006 Daikin AC Controls Engineering Department Generated Submittal Data www.daikinac.com (Daikin's products are subject to continuous improvements. Dalkin reserves the tight to modify product design, specifications and Information in this data sheet without notice and without incurring any obligations) if5),CillEgBIU AC absolute comfort Project Name: Submittal Data Sheet BRC1 E72 - New Navigation Controller Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit #: Reference: Drawing #: Face Decal Options: • Face decal options to hide unnecessary buttons o Hidden buttons can be used/accessed by service personnel without removing the face decal due to its flexibility Fluor n 71. Used with Single Setpoint mode Dual Setpoint mode Model BRC1E72RM BRC1E72RF BRC1E72RMF ! BRC1E72RM2 BRC1E72RF2 BRC1E72RMF2 •' •°• : . ., • On/Off X X X X X X Mode X X X X Fan X X X X Up, Down X X X X X X Left, Right X X x Menu/OK Cancel Daikin AC (Americas), Inc., 1645 Wallace Drive, Suite 110, Carrollton, TX 75006 Daikin AC Controls Engineering Department Generated Submittal Data www.daikinac.com (Dalkin's products are subject to continuous Improvements. Daikin reserves the right to modify product design, specifications and Information in this data sheet without notice end without Incurring any obligations) VDAIKIN /1C' absolute comfort Project Name: Intelligent Touch Manager Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #: For use with the following VRV Models: FXAQ, FXDQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXOQ, FXSQ, FXTQ, FXZQ For use with the following Daikin SkyAir Models: FAQ, FCQ, FHQ, FTQ Capacity: Model No. intelligent Touch Manager DCM601A71 iTM Plus Adapter (option) DCM601A72 Maximum Indoor Unit Groups: 64 64 Max Indoor Units: 128 128 Max Outdoor Units: 10 10 *Systems Total: 512 Indoor Unit Groups (1024 Indoor Units) Operating Details: Power Supply (Externally supplied): 24 VAC, 60 Hz 24 VAC, 60 Hz Power Consumption: 23 Watts 23 Watts Operating Temp Range: 32-104°F 14 - 122°F Operating Humidity Range: 85% or less (w/o condensation) 85% or less (w/o condensation) Dimensions (WxHxD): 11.42 x 9.57 x 1.97 in. 6.30 x 5.87 x 2.41 in. Weight (Mass): 5.3 lbs. (2.4 kg) 1.1 lbs. (0.5 kg) Certifications: FCC Part 15 Class B Communication: DIII-NET Systems: 1 1 RJ-45 (Ethernet) 100Base-TX or 10Base-T 2 N/A USB Port USB2.0 (2GB to 32GB) 1 RS485 (19 - 22 AWG) 1 N/A 1 Input Terminals: Digital Input forced shutdown of all indoor unit systems 1 N/A Digital Input and/or Pulse Input Terminals: 3 x 10 mA @ 16 VDC/ 3 x 1 pulse at 1 or 10 kWh at 100 ms interval 4 x 10 mA @ 16 VDC/ 4 x 1 pulse at 1 or 10 kWh at 100 ms interval Configuration and engineering for each project is necessary Ifntellige anager a b.Mr at a iiririr !► cacics33ii •:,..":i L3 C3 . C'! C3 __ ta�rtirai---- - - Standard Features: • Web/Email Software • One year warranty Software Options: • Power Proportional Distribution (PPD) Software (DCM002A71) • Energy Navigator Software (DCM008A71) Hardware Options: • iTM DIII-NET Plus Adapter(DCM601A72) for expanding indoor unit groups up to 512 groups (1024 indoor units) • WAGO I/O unit for controlling/ monitoring of external equipment via Di, Do, or Ai • Digital Input (DEC101A51-US2) for monitoring external equipment • Digital Input/Output (DEC102A51-US2) for controlling / monitoring of external equipment • iTM Integrator (DCM601A73) for controlling/monitoring up to 5 iTMs The Power Proportional Distribution (PPD) feature supplies the user with a reasonably calculated apportionment of the total power consumption by the Daikin air-conditioning system to individual units on the system. Because input to the PPD includes measured pulses in the refrigerant system and because the air-conditioning system includes a number of variables, to include operating temperatures and pressures, piping lengths, heat exchange rates and others, no meter -type apportionment of individual user's consumption can be made. However, the PPD feature provides an apportionment methodology that uses highly advanced technology as applied to the many variables in the air-conditioning system. *Note: See Management Size on page two for System Total explanation Daikin AC (Americas), Inc., 1645 Wallace Drive, Suite 110, Carrollton, TX 75006 Daikin AC Controls Engineering Department Generated Submittal Data www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and Information in this data sheet without notice and without incurring any obligations) VDAIKIN AC absolute comfort Project Name: Intelligent Touch Manager Location: Approval: Engineer: Submitted to: Submitted by: Date: Construction: Unit #: Reference: Drawing #: Features / Benefits: • Management size - up to 512 indoor unit groups (1024 indoor units) • The iTM can manage one (1) DIII-Net system which can have up to 64 indoor unit groups (128 indoor units). • The iTM can manage up to eight (8) DIII-Net systems with the addition of the iTM Plus Adapter which can manage one (1) DIII-Net system each. This means up to seven (7) iTM adapters can be daisy chained to the iTM. • Web Accessibility • Web and Alert Email function standard with iTM • Web browser shows the same screen as iTM touch screen • All iTM configuration/setup can be done through Web Option or touch screen • Visual Navigation Screen • Floor plan layout view is available • Easy installation • Wall mount and flush mount installation • Automatic indoor unit registration and indoor unit model detection • 24 VAC 60 Hz • Easy Engineering • iTM can be configured off site via Pre-setting Tool • All data can be uploaded and downloaded by USB flash drive • History • All operations, automatic controls and status changes are stored in history (up to 1,000,000 items) • D-Net compatible • Energy management (Optional) • Visualization of energy consumption data • Pinpoint areas where energy is wasted • Power Proportional Distribution (PPD) (Optional) • Tenant billing • Building facilities management • Building facilities are connected by using WAGO I/O system (optional) • I/O configuration for Digital Input, Digital Output, and Analog Input • The iTM is equipped with 3 digital/pulse inputs and the iTM Plus Adapter comes equipped with 4 digital/pulse inputs Intelligent Touch Manager (iTM) DCM601A71 iTM Dill -NET Plus Adapter DCM601A72 Specifications of Communication Cabling (DIII-NET) Type 2-conductor, stranded, non -shielded copper cable / PVC of vinyl jacket Size AWG 18-2 Total Length Maximum wiring distance between units 3,280 ft. Total wire length 6,550 ft. Daikin AC (Americas), Inc., 1645 Wallace Drive, Suite 110, Carrollton, TX 75006 Daikin AC Controls Engineering Department Generated Submittal Data www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and Information in this data sheet without notice and without incurring any obligations) r7iD,(2.ECZOR5 Submittal Data Sheet 8.0-Ton Concealed Ceiling Unit FXMQ96MVJU FEATURES • Greater design flexibility with a capacity range extended to 96 MBH • Improved ductwork and filtration flexibility with high CFM and ESP capabilities of up to 1.1" W.G. • Standard Limited Warranty: 10-year warranty on compressor and all parts VAS, REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 8 2015 City of Tukwila BUILDING DIVISION • eta C. railED 111111 R-41 OA [INVERTER] RECEIVED CITY OF TUKWILA JUL 31 2015 PERMIT CENTER Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 1 of 3 Submittal Data Sheet 8.0-Ton Concealed Ceiling Unit FXMQ96MVJU PERFORMANCE Indoor Unit Model No. Type: FXMQ96MVJU Ducted Rated Cooling Capacity (Btu/hr): 96,000 Sensible Capacity (Btu/hr): 70,970 Cooling Input Power (kW): 1.680 Rated Heating Capacity (Btu/hr): 108,000 Heating Input Power (kW): 1.68 Indoor Unit Name: 8.0-Ton Concealed Ceiling Unit Rated Cooling Conditions: Rated Heating Conditions: Rated Piping Length(ft): Indoor (°F DBMB): 80 / 67 Ambient (°F DBM/B): 95 / 75 Indoor (°F DBMS): 70 / 70 Ambient (°F DBMS): 47 / 43 Rated Height Separation (ft): INDOOR UNIT DETAILS Power Supply (V/Hz/Ph): Power Supply Connections: Min. Circuit Amps MCA (A): 208-230 / 60 / 1 L1, L2, Ground 10.70 Max Overcurrent Protection (MOP) (A): Dimensions (HxWxD) (in): Panel (HxWxD) (in): Net Weight (Ib): Airflow Rate (H/L) (CFM): Moisture Removal (Gal/hr): Gas Pipe Connection (inch): 2,541/2,188 7/8 Liquid Pipe Connection (inch): 3/8 18-1/8 x 54-3/8 x 43-5/16 302 Condensate Connection (inch): 1 Sound Pressure (H/L) (dBA): 49/46 Sound Power Level (dBA): Panel Weight (Ib): Ext. Static Pressure (Rated/Max) (inWg): 0.95 / 0.95 Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 2 of 3 r/7Ri)1:\ ocaocf Submittal Data Sheet 8.0-Ton Concealed Ceiling Unit FXMQ96MVJU DIMENSIONAL DRAWING 32-03/1 6 lele (All amid) E 0 to r. N Discharge side C • • \ U ♦• N ♦ I ♦ i • Cs I \ v — \ • \\\\\\\\\\♦ , . :'..., IIi]ectitt 11Ie°23-5/8 it title y 45-3/16 32—#3/16 Ills (All erutd) co c rn 32—{ 1/4 Itl (All amid) 43— 6 or more ( errvca Irue Section side (Note,2) FXMQ M72_96 Unit (in.) 9-5/8 it U it .J I=11111111111111111111 lir-.— A View Ductwork Opening: Model No. Supply Opening Height FXM072,96MVJU 114.3116' Width 48.7r16' Return Opening Height 14-3/16' Width 4&7/16' (Note: 0pering dinensnn base on Faring Hole Center) CO N. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 3 of 3 r7DaIKIN Submittal Data Sheet 8-Ton VRV-IV Heat Pump Unit - 460V RXYQ96TYDN FEATURES • Variable Refrigerant Temperature (VRT) control allows the VRV IV to deliver up to 28% of improvement in seasonal cooling efficiency compared to previous Daikin VRV heat pump systems • Same product structure for 230V and 460V simplifies ordering • The rated seasonal cooling efficiency has been improved by an average of 11% compared to VRV III • Improved efficiency with IEER values now up to 28 • Larger capacity single modules ranging up to 14 tons and systems up to 34 tons allow for a more flexible system design • New configurator software designed to simplify the commissioning and maintenance of the system • Larger capacity single modules allow for opportunity to reduce electrical connections, piping connections and outdoor unit mounting fixtures • System wide auto -climate adjustment technology to increase the energy efficiency • MI inverter compressors to increase the efficiency and avoid starting current inrush • Assembled in the US to increase flexibility and reduce lead times • Standard Limited Warranty: 10-year warranty on compressor and all parts BENEFITS • 3 row 7mm heat exchanger coil improves efficiency • Inverter control board cooled by refrigerant to avoid influence from abient temperatures • Heat exchanger coil wraps around on all 4 sides of the unit to increase the surface area / efficiency • Designed with reduced MOP to optimize installation cost • Digital display on the unit for improved and faster configuration, commissioning, and trouble shooting. difAlf IV .t..i CERTIFIED- ..... Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 1 of 3 Submittal Data Sheet 8-Ton VRV-IV Heat Pump Unit - 460V RXYQ96TYDN PERFORMANCE Outdoor Unit Model No. Type: Rated Cooling Capacity (Btu/hr): Nom Cooling Capacity (Btu/hr): RXYQ96TYDN Heat Pump 92,000 Outdoor Unit Name: Unit Combination: Rated Cooling Conditions: 8-Ton VRV-IV Heat Pump Unit - 460V Rated Heating Conditions: Indoor (°F DB/WB): 80 / 67 Ambient (°F DBMS): 95 / 75 Indoor (°F DBMB): 70 / 70 Ambient (°F DBMS): 47 / 43 Cooling Input Power (kW): 6.34 Rated Heating Capacity (Btu/hr): 103,000 Rated Piping Length(ft): Rated Height Difference (ft): Nom Heating Capacity (Btu/hr): Heating Input Power (kW): 6.62 IEER (Non-Ducted/Ducted): Heating COP (Non-Ducted/Ducted): 0.00 Heating COP 17F (Non-Ducted/Ducted): 2.9 / 2.6 OUTDOOR UNIT DETAILS Power Supply (VMz/Ph): Power Supply Connections: Min. Circuit Amps MCA (A): 460/60/3 L1, L2, L3 Ground 20.6 Max Overcurrent Protection (MOP) (A): 25.00 Max Starting Current MSC(A): Rated Load Amps RIA(A): 10.2 Compressor Type Inverter Capacity Control Range (%): 20 - 100 Capacity Index Limit: 48.0 - 125.0 Airflow Rate (H) (CFM): 5,827 Gas Pipe Connection (inch): 7/8 Liquid Pipe Connection (inch): Dimensions (Height) (in): 66-11/16 H/L Pressure Connection (inch) H/L Equalizing Connection (inch) 30-3/16 Sound Pressure (H) (dBA): 553 Sound Power Level (dBA): Max. No. of Indoor Units: Dimensions (Width) (in): 48-7/8 Dimensions (Depth) (in): Net Weight (lb): 3/8 61 16 Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incuning any obligations) Page 2 of 3 ITC\ i Submittal Data Sheet 8-Ton VRV-IV Heat Pump Unit - 460V RXYQ96TYDN SYSTEM DETAILS Refrigerant Type: R-410A Cooling Operation Range (°F DB): Holding Refrigerant Charge (Ibs): 22.7 Additional Charge (lb/ft): Pre -charge Piping (Length) (ft): Heating Operation Range (°F WB): Max. Pipe Length (Vertical) (ft): Cooling Range wBaftie (°F DB): Max. Pipe Length (Total) (ft): 540 Max Height Separation (Ind to Ind ft): 0 23 - 122 0-77 295 Heating Range wBatge (°F WB): DIMENSIONAL DRAWING 4-9/16(15) x 7/8(22.5) Oblong holes (rourc.,alion bolf Me) 4-60 42-3/8(1076 ) ( Rd o1 (ambler' bag Wes) 14 �11 3-1/8(98j. 4-3/16'107 ) 10-11/16(272 ) 19-3/4(502 ) 48-7/8(1242 ) Terl II 77, 0 Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Page 3 of 3 rP202171=7 AC0 absolute comfort Proiect Name: Location: Engineer: Submitted to: Submitted by: Reference: Performance MERV 13 Kit Model No.: DACA-MQ96M-13-1K Initial Pressure Drop (IPD in H20): See Table 1.0 Final Pressure Drop (FPD in H20): .390 Details Air Filter Dimensions (HxWxD nominal): 18.00" x 24.00" x 4.00" Air Filter Dimensions (HxWxD exact): 17.38" x 23.38" x 3.75" Cabinet Dimensions (HxWxD): 17.94" x 49.43" x 25.00" Net Weight (Ibs): Air Filter, Cabinet and Packaging: 72.45 Air Filters (2 required): 7.40 Cabinet: 56.78 Replacement Filter(s): Part No. (each): Part No. (box of 6): DACA-MQM-13-1 DACA-MQM-13-1 B Description: Air Filter, AmAir 1300 Nominal Size MERV 13 Appearance — MERV 13 Air Filter and Cabinet Kit Submittal Data Sheet Approval: Date: Construction: Unit #: Drawing #: Table 1.0 Performance Data Model No. Airflow CFM Daikin FXMQ72MVJU 2047 FXMQ96MVJU 2542 Filter IPD Filter FPD .120 .390 .180 .390 1 /2 Daikin AC (Americas), Inc., 1645 Wallace Drive, Suite 110, Carrollton, TX 75006 Daikin AC TRL Generated Submittal Data www.daikinac.com (DaIldn's products are subject to continuous Improvements. Daikin reserves the right to motify product design, specifications and information In this data sheet without notice and without incurring any obligations) VDAIKIN Ac° absolute comfort Proiect Name: i a -aaTee Illt Location: Approval: Engineer: Submitted to: Submitted bv: Date: Construction: Unit #: Reference: Drawing #: Dimensional Drawing — DACA-MQ96M•13.1 K 49.430 17.850 24965 a TIL 1 a .965 49.430 a IT 1.503 L � 1.503 65A'0 .965 24A00 .965 —.'• • •Q • • • 15.835 17.�. • • • .965 2/2 Daikin AC (Americas), Inc., 1645 Wallace Drive, Suite 110, Carrollton, TX 75006 Daikin AC TRL Generated Submittal Data www.daikinac.com (Dali in's products are subject to continuous improvements. Daildn reserves the right to madly product design, specifications and information in this data sheet without notice and without incurring any obligations) _►} ME STACK Q p '' M MOTOR FRAME 122 4 28.25 28.25 29.62 184T 150 4 30.31 30.31 33.50 215T 165 4 34.00 34.00 41.94 256T 182C 3 34.00 34.00 41.94 286TS 182 3 37.88 37.88 44.50 286TS 200C 3 37.88 37.88 44.50 286T 200 3 41.00 41.00 49.37 286T 222C 3 41.00 41.00 49.37 326T 222 3 45.25 45.25 51.37 326T 245C 3 .. 41.00 41.00 49.37 326T 245 3 ' 49.38 49.38 56.68 326T 270C 2 • 45.25 45.25 51.37 365T 270 2 54.00 54.00 61.13 365T 300C 2 49.38 49.38 56.68 365T 300 2 60.00 60.00 64.38 365T 330C 2 54.00 54.00 61.13 405T 330 2 65.00 65.00 62.88 405T 365C 2 60.00 60.00 64.38 444T 365 2 71.50 71.50 65.63 444T REVIEWED FOR CODE COMPLIANCE Ii APPROVED AUG 2 8 2015 . Model City of Tukwila BUILDING DIVISION MPLQN - 122C PLFN, MPLFS PLQN, MPLQS heel Type = 9-Bladed Airfoil = 12-Bladed Airfoil using N = Insulated S = Structure Only, Non -Insulated W Housing Size C = Compact No letter at the end of the fan size = Standard Housing Wheel Diameter RECEIVED 12.25" to 36.5" CITY OF TUKWILA JUL 31 2015 PERMIT CENTER 5959 TRENTON LftZav NORTH MINNEAPOLIS, 1M 'Mc\ 55442-3237 � imhiesr rkjR = IED-P.249 Y t) PHONE: 763-551-7600 a(ty33 WWW.TCF.COM 763-551-7601 Customer: AIR REPS LLC Job ID: 69 Date: April 10, 2015 LL 5 0 0 i O LL 0 m O O 5 cc d O) O co Tr 0 LL N O co L a 5 a a 0 0 CO a x 0 a x m 0 0 a. a a m a c n 0 0 a y v 0 0 0 5 U 0 0 N 4 J U cn CD 0 0 2 0 J a O) F Q Z Ver 0.0 October 2013 - Created 03-11-2015 CO LI: C ~I U Q G0 o • U TP m E 0 N O } O ▪ N N -� O C O N 0 C 0 • 0 U a c E 4) H All quotations per Twin City Fan April 10, 2015 Fan Accessories Accessories Included - MPLQS, 165, 4 3600 RPM, 460V, 3Ph, 60Hz , TEFC - Premium , 254T Mount TCF Motor Optional accessories CD CO 1- No Accessories r SUBMITTAL Job Name: Museum of Flight Fans & Blowers Twin C.• Tag: N/A Customer: AIR REPS LLC Job ID: 69 Date: April 10, 2015 MPLQS - Modular Plenum Fan, Airfoil 12-Blades, Arr.4, Non - Insulated Construction Features • Type MPLQS wheels are constructed of aluminum using airfoil -shaped blades. All hollow blade wheels shall be continuously welded around all edges. • Fan frame and panels are corrosion resistant, galvanized steel construction. The inlet panel incorporates a removable spun inlet cone designed for smooth airflow into the fan wheel. Approximate weight each, includes fan, motor and accessories. Temperature: 70 °F Altitude: 100 ft Motor Data HP 15 RPM T Volt/Ph/Hz 3 600 460V/3/60 Enclosure TEFC Efficiency: Premium Octave Bands Sound Data Level at Inlet 1 Level at Outlet 1 2 3 4 5 6 7 8 LwA dBA Sones 95 86 84 96 91 87 86 86 97 82 47 97 97 96 98 95 93 92 87 101 86 63 LwA: The overall (single value) fan sound power level in dB re. 10.12 Watts, 'A' weighted. dBA: Estimated sound pressure level (re:0.0002 microbar) based on a single ducted installation at 5 ft., using a directivity factor of 1. Accessories Included Ext. Lube Line, Impeller Side Motor Bearing for Regreasable Bearings Mount TCF Motor 12.0- 10.5- 9.0- 3.0- 0.0- Standard Plot 0 10 20 30 40 50 60 Volumetric Flow (CFM x 100) 70 80 12.0 10.5 9.0 7.5 nt 5 .0 W S 4.5` 3.0 1.5 0.0 Ver 0.0 October 2013 - Created 03-11-2015 Updated 04-10-2015 Owner Jim Boles Air Reps Page 2 of 3 Fans & Blowers Twin Ci AMCA Statements Tag: Customer: AIR REPS LLC Job ID: 69 Date: April 10, 2015 1. TCF certifies that the model MPLQS is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. 2. Performance certified is for Installation Type A: Free inlet, Free outlet. 3. Power rating (BHP) does not include transmission losses. 4. Performance ratings do not include the effects of appurtenances (accessories). 5. The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. 6. Ratings do not include the effects of duct end correction. 7. The A -weighted sound ratings shown have been calculated per AMCA Standard 301. 8. The AMCA Certified Ratings Seal applies to LwA, LwiA and LwoA ratings only. 9. dBA levels are not licensed by AMCA International. almca �1, OERTIi1ED RR HIGS / /SQUAD, AIR riroimIMa iEt Ver 0.0 October 2013 - Created 03-11-2015 Updated 04-10-2015 Owner Jim Boles Air Reps Page 3 of 3 Peace of Mind - Built-in Built-in timers External timer circuits are no longer needed. Built-in timers - utilizing the real-time clock - allow starting and stopping the drive or changing the speed according to a set time and date. Relay outputs can be operated by the timers to control any auxiliary equipment on site. BACnet, N2, FLN and Modbus embedded Commonly used HVAC fieldbuses are embedded into the memory of the drive, ensuring that they are always there if you need them. ABB has a long history in build- ing automation, with more than 200,000 installed drives utilizing serial communications. LonWorks and Profibus LonWorks, Profibus and other plug-in modules fit under the cover of the drive. A single twisted pair avoids great lengths of conventional cabling, reducing cost and in- creasing system reliability. Swinging choke - up to 64% less harmonics ABB's patented swinging choke means the ACH Series Drive reduces harmonics by up to 64% at partial Toads when compared to a PWM AFD with no chokes. There is no need to oversize the supply cables. Pre -configured HVAC application macros 15 different HVAC application macros are pre-pro- grammed into the HVAC drive. Application macros for supply and return fans, cooling tower fans, booster pumps and condensers are available, just to name a few. The user can create two additional application mac- ros, selectable manually or through a customer contact. To illustrate this, the user can create „summer" and „winter" application macros and select between these according to the time of the year. The motor can deliver full output at 40 °C - shouldn't the VFD do the same? ABB's HVAC drive is rated for continuous operation to 40°C with full current, without being compromised by temperature variations within any 24-hour period. Full circulation is available, precisely when needed - usu- ally, when it is hot outside. Similarly, Type 12 units can be operated without the need for de -rating up to 40°C. And, at 50°C, only 10% de -rating is required for both UL Type 1 and UL Type 12. Built-in EMI/RFI filters The ACH Series Drive is designed to meet the EMC product standard EN61000-3-12. These standard filters eliminate the need for any external filtering hardware. 2 ABB ACH550-UH Catalog Interactive maintenance assistant Maintenance scheduling no longer requires guesswork. The HVAC drive alerts you when maintenance is required based on your individual requirements. Fault logger The fault logger of the HVAC drive is especially use- ful in tracking down drive trips through its use of the real-time clock. In addition to recording both time and date, the fault logger also takes a snapshot of 7 diagnostic values - like motor speed and output current. You know what happened and when. Two PID controllers as standard The HVAC drive has two independent PID control- lers built in. As an example: one PID controller works with the AFD to maintain the duct static pressure; simultaneously, the other PID controller can be used to control a separate external device, e.g. a chilled water valve. All of this can, of course, be monitored and controlled through serial commu- nications. Wide power range Drives are available to cover the vast majority of HVAC applications reducing cost and increasing system reliability. 1 to 100 Hp @ 208/240 V 1 to 550 Hp @ 380/480 V 2 to 150 Hp @ 500/600 V Interactive diagnostic assistant Should a fault occur, the diagnostic assistant displays, in plain language, possible causes and potential solutions. Flux optimization This standard feature means the drive supplies only the voltage and current necessary to drive the load. This results in reduced energy consumption and much lower motor noise levels. Silent operation mode further reduces motor audible noise for sensi- tive applications. Versatile software tools DriveWindow Light 2 further facilitates commis- sioning and maintenance. Pump & Fan Save helps calculate energy savings and pay -back times. ABB's Harmonics Calculator allows the engineer to run harmonics contribution estimates. ABB ACH550-UH Catalog 3 Drive features Keypad and firmware features The new ABB ACH Series Drive Keypad takes the typical operator interface to a new level. It uses full language, not codes, and emulates the human interface of a cell phone. Using the intuitive interface, you control the panel's functions in one of 14 selectable languages. The keypad also features two soft keys; their functions change according to the operat- ing state of the panel. Hand -Off -Auto buttons provide local control for local- speed and start/stop control. Diagnotic Assistant Includes several new -to -the -market features such as diagnostic Assistants. For example, if there's a trip off line, pressing the Help Key brings the user to the Diagnostic Assistant; it suggests possible causes of the trip and probable corrective actions. Programming Assistants Configures the drive for an application. For example, the PID Assistant prompts the user through a series of 12 questions; and uses the answers to these questions to set 26 param- eters inside of the drive's program. No need to navigate the drive menus! The Maintenance Assistant Alerts the user when equipment maintenance is required, based on selected inputs. Utilize the Revolution Counter and Maintenance Assistant to signal personnel when it's time to replace the pump packing. The Help Button Brings up a description of what the effect of parameter changes would be — in full sentences. Fault Monitoring Faults can be time and date stamped via the real-time clock. A fault logger stores status information such as amps, volts and presence of a run command at the time of the fault. smingeni Patented Swinging Choke (Reactor) Reduces Harmonics ABB ACH Series Drives include a 5% swinging choke. Filter chokes fall into two categories: the Linear Choke and the Swinging Choke. A Linear Choke has an inductance that is relatively constant up to the rated value of current. These chokes are designed so that they will not saturate when carry- ing all of the load current. The Swinging Choke is used in applications where the change in inductance is inversely proportional to the change in load current (such as variable torque applications). A well designed swinging choke provides the proper inductance to ensure adequate filtering and the continuous flow of current through the rectifier for all levels of load current. From the graph (at right), it can be seen that the built-in swinging choke in all ABB HVAC Drives allows the drive to deliv- er over 25% less harmonics at partial loads than a conventional 3% reactor; more than 60% less harmonics than a drive with no reactor. The reduced harmonics means the drive input current is the same as the output current. No need to oversize branch circuit wiring to comply with NEC 430 (X. Adjustable Speed Drive Systems) Variable Torque Load vs. % speed 90 80 70 i5 60 To use 20 50 40 10 0 40% 60% % Speed 80% 100% PWM drive w/o choke PWM drive w/3% choke ACH550 4 ABB ACH550-UH Catalog 55% less harmonics at full load, better than 64 % less harmonics at partial loads. (HVAC drives spend most of their operating hours at partial load. Unity Controller Building Management System Fireman's Override Safeties and '', (smoke purge) Fireman's Override Fire / Freezestat Overpressure Damper Open Proof Damper Actuator and End Switch Open Damper * NOTE: If serial communications is compromised (cut wire), the VFD remembers the last good setpoint command and both PID loops continue functioning. 1. The BMS commands start/stop; internal/external PID setpoints; command digital (relay) outputs, and analog (4-20mA) outputs and reset faults. The BMS reads drive outputs; controlled variable feedback; Hand/Auto selected indication; kWhrs (R); Operating hrs (R); drive amps (broken belt indication); drive temperature; all warnings, faults, and much more. 2. Receive and monitor hard -wired devices -- firestat/ free- zestat safety contacts, smoke purge commands -- over the serial link. 3. Open an isolation damper, override a VAV box or any de- vice that requires a maintained contact closure for control. Receive damper end -switch proof contact. A Valve Position Command (4 - 20 mA) Temp Feedback (4 - 20 mA) External PID Loop Valve Position * Command Pressure Feedback (4 - 20 mA) Process PID Loop Hot H, O Valve Chilled H, O Valve Fan Speed (pressure) Control 4. The Keypad Display indicates feedback and setpoint in inches of water column - or programmable units intuitive to the user. 5. BMS commands a drive analog output to control hot water valves or any device requiring a 4-20mA analog input. 6. The drive's external PID Loop Controller controls a chilled water valve or any device requiring a 0-20mA input. Feed- back signal is hard -wired to AFD and set -point is sent via serial comms. 7. Use the drive's process PID Loop Controller to maintain supply fan pressure via adjusting fan speed. Pressure feed- back is hard -wired to AFD and setpoint is sent via serial comms. ABB ACH550-UH Catalog 5 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director March 2, 2016 Fenton Kraft 9404 E Marginal Way S Tukwila, WA 98108 RE: Request for Extension #1 Permit Number M15-0099 Dear Mr. Kraft, This letter is in response to your written request for an extension to Permit M15-0099. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through August 27, 2016. If you should have any questions, please contact our office at (206) 431-7165. Sincerely, Wi4t1&. ft Rachelle Ripley Permit Technician File: Permit No. M15-0099 WAPer,nit Center\Extenslon Letters\Permits\201511415-0041 Permit Extension #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Rachelle Ripley From: Fenton Kraft <FKraft@museumofflight.org> Sent: Tuesday, February 16, 2016 5:49 PM To: Rachelle Ripley Subject: Museum of Flight Mechanical and Electrical Permit Extension Request Hello Rachelle, I would like to request an extension of permit numbers-A/115-0099 and EL15-0661 in order to allow us time to complete the final stages of our Boeing 787 heat pump project. Due to the size of the aircraft and the construction sequencing of the Aviation Pavilion project (the future home of the 787), the aircraft was moved to a temporary location in the new Aviation Pavilion building while adequate clearances in the exterior walls remained. The move of the aircraft to its permanent location is planned for March 1st of this year. At present, the majority of the mechanical equipment and electrical cabinets have been installed in the aircraft cargo bay, but the placement of the heat pump outdoor unit and the installation of the interconnecting refrigerant lines, electrical disconnects, conduit, power and control wiring await the final placement of the aircraft. Once this move is completed, we will prioritize the installation of the above listed equipment, followed by the remaining sheet metal, insulation, sensors, and automation equipment. While we expect to have the 787 heat pump system operational by our June 24th opening of the Aviation Pavilion, a six month permit extension would be extremely helpful to address any final commissioning items that might arise. Please let me know if any additional information would be helpful. Thank you very much for considering my request. Sincerely, Fenton Fenton Kraft Engineering Services Manager Museum of Flight 206 795-5831 c THE. MUSEUM OF FLIGHT Fenton Kraft I Engineering Services Manager The Museum of Flight 9404 East Marginal Way S Seattle, WA 98108 Work: +1 (206) 768-7125 www.museumofflight.org Request for Extension # 1 Current Expiration Date: 4 21 Extension Request: L4 Approved for lg-d days Denied (provide explanation) Signature/Initials t Z 1 City of Tukwila Department of Community Development 1/4/2016 FENTON KRAFT 9404 E MARGINAL WAY S TUKWILA, WA 98108 RE: Permit No. M15-0099 MUSEUM OF FLIGHT - 787 9404 E MARGINAL WAY S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/27/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/27/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File No: M15-0099 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development August 18, 2015 FENTON KRAFT 9404 E MARGINAL WAY S TUKWILA, WA 98108 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0099 MUSEUM OF FLIGHT - 787 - 9404 E MARGINAL WAY S Dear FENTON KRAFT, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) All Structural Drawings and structural calculations sheets to be stamped (original signed wet stamp, not copied) by Washington State licensed architect, structural engineer or civil engineer. (BUILDING REVIEW NOTES) 1. Please submit documents and plans produced by a registered design professional (architect and/or engineer) with wet stamp and wet signatures on each plan sheet and any calculation packets (front sheet only), to include the equipment and control component sheet. Electronic copies shall not be accepted. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, Rachelle Ripley Permit Technician File No. M15-0099 63nn,Qnuthrontor Rnulavnrd .Cuito ',inn • Tukwila Wnchinatnn 9R1RR • Phnno 7n6-4?1_4 7n • Fnr 71)6-d?1_?665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0099 DATE: 08/24/15 PROJECT NAME: MUSEUM OF FLIGHT - 787 SITE ADDRESS: 9229 E MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: e Building Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/25/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/22/15 Approved Corrections Required Approved with Conditions Pc Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0099 DATE: 08/03/15 PROJECT NAME: MUSEUM OF FLIGHT - 787 SITE ADDRESS: 9404 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: tit Pi Building ivision YU Public Works A'WO Mv1`��i Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 08/04/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/01/15 Approved Corrections Required Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: o0q/2©1S- O Response to Incomplete Letter # LI Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: H /Jr r 00 9J Project Name: Mus.tuvii Vj,'�� flea+ t i System Project Address:.9404 Fclst Mal {wu ( ' hr SnuZt) J Contact Person: Fe 4r i IA/ Kva' i Phone Number: 206 79.E - 233 Summary of Revision: AUG 2.4' 2015 PCflM Ti'CENTER Sheet Number(s): t4—,1 l M I j M 2,. MS . r i 44, I E "Cloud" or highlight all areas of revision including date of revision c- Received at the City of Tukwila Permit Center by: {1--Entered in TRAKiT on STATE OF WASHINGTON) COUNTY OF KING ) ✓l Y`Cli�"�' CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: F 1 _ OC EL-S n( f ss. [please print name] , states as follows: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 13 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 Owner/Owner's ;,ent* Signed and sworn to before me this 031sfi day of'(9-S , 20 NM.. zu.w a Y PUBLIC in and for the State of Washington Residing at /06a Name as commissioned:( My commission expires: , County D(act(i s� 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds, a valid electrical contractor's', license under chapter 19;28 RCW that 'employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately.,; j appropriate o of`a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. * Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.