Loading...
HomeMy WebLinkAboutPermit M15-0101 - PROLOGIS - UPLAND TI - ROOFTOP PACKAGE UNIT, EXHAUST FANS, VENT ETCPROLOGOS -UPLAND TI 1139 ANDOVER PARK W M15-01O1 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3523049102 1139 ANDOVER PARK W Project Name: PROLOGIS - UPLAND TI MECHANICAL PERMIT Permit Number: M15-0101 Issue Date: 8/19/2015 Permit Expires On: 2/15/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: AMB PROPERTY CORP 60 STATE ST STE 1200 C/O RE TA , BOSTON, WA, 02109 HEATH HAMBLEN 4102 B PLACE NW , AUBURN, WA, 98001 UNIVERSAL REFRIGERATION INC 4102 "B" PL NW , AUBURN, WA, 98001 UNIVERI159RF Phone: (253) 939-5501 Phone: (253) 939-5501 Expiration Date: DESCRIPTION OF WORK: INSTALL (1) ROOFTOP PACKAGE UNIT AND AIR DISTRIBUTION SYSTEM. INSTALL (2) CEILING EXHAUST FANS AND VENT THRU ROOF. NATURAL GAS PIPING FROM EXISTING MAIN LINE. Valuation of Work: $16,018.00 Type of Work: NEW Fuel type: GAS Fees Collected: $415.74 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. i�7 // Signature: r Print Name: 6V(4, J�(I Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. MIS • O` 01 Project No. Date Application Accepted: �0 14I /�( Date Application Expires: ' (/ ((% (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 113q A„IboiJrra. i'AiLL Wbb� Tenant Name: PKoiod;�S - [p(Anft,T T PROPERTY OWNER Name: �ac(osis ic, . t Address: 12. 120 (10.1-etaA \%-DaIv'te tSJik II() City►-Tvl. 1 iA tate: ta5K Zipt 1 CONTACT PERSON - person receiving all project communication Name: Shane (Heat Bryan Chuck Address: 4102 B P1 NW City: Aubum State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email: @universalrefrig.com King Co Assessor's Tax No.: Usso4- q 10`L Suite Number: 4 fA Floor: New Tenant: 2. Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B P1 NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNIVERI 159RF Exp Date: 04/01/2014 Tukwila Business License No.: $(JS - o j 31 ztf 00 Valuation of project (contractor's bid price): $ 1LP1 1 • 11 ` tt Describe the scope of work in detail: �Nst.4 ( 124 (.o� �A�ZtiG�Q Jr1iA ,,16 Ai R UiS�,2lOJ�ioa stisLvot �a5�a►1i (23 (.0;,sty syiett eJ- Wit, v6,41-460 czo4. 11, 1 cr v.A.k: fa 1: nit, Use: Residential: few ❑ Replacement ❑ Commercial: New Q' Replacement Fuel Type: Electric ❑ Gas E 1' Other: H: Applications\Fomts-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit I <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Z Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in'writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEBO; . ' . , IZED AGENT: Signature: l Date: 813f IS Print Name: Day Telephone: (253) 939-5501 Mailing Address: 4102 B P1 NW Auburn WA 98001 H:\Applications\Fonns-Applications On Line\201 I ApplicationsVvlechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $628.81 EL15-0671 Address: 1139 ANDOVER PARK W Apn: 3523049102 $86.31 ELECTRICAL $82.20 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $82.20 TECHNOLOGY FEE $4.11 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.11 M15-0101 Address: 1139 ANDOVER PARK W Apn: 3523049102 $415.74 MECHANICAL $399.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $287.30 PLAN CHECK FEE R000.322.102.00.00 0.00 $79.95 TECHNOLOGY FEE $15.99 TECHNOLOGY FEE R000.322.900.04.00 0.00 $15.99 PG15-0089 Address: 1139 ANDOVER PARK W Apn: 3523049102 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.88 TOTAL FEES PAID BY RECEIPT: R5872 $628.81 Date Paid: Tuesday, August 04, 2015 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 49787 Printed: Tuesday, August 04, 2015 3:57 PM 1 of 1 r' rIffSYSIEMS 1191 INSPECTION RECORD Retain a copy with permits ®(a/ INO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro' ct: Type of inspection: c Idea( Fr ram. -I. V Ad ress. l (35. ` .'G Lies- ?art_ck1 Date Called: Special Instructions: rIo—cr—or Date Wanted: a.m. p.m. Requester: Phone No: 7.q, Approved per applicable codes. LJ Corrections required prior to approval. LCOMMENTS: Inspector: Date:(--c(- r (--- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. icc rINSPECTION RECORD OA Retain a copy with permit INS INO. itittr-0 is PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro t: uce Type_of Insspscction:fart In'_l�(i` ' Address: 1(3 « (otitr ('ur�l 'r , Date Called: Special Instructions: )�A Date Wanted: (0-0- (S a.m. p.m. Requester: Phone No: Approved per applicable codes. COMMENTS: tc fff/i � (ot r � t rb f felt. ,'ers4 (`c Corrections required prior to approval. A C Inspector: Datea4 --b ,- f r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ket INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350m Pr• "%o"��efc'�t: �� I Type of Ins ection: ,` I ''v\ Address: 1(3 1 /1�JoVQr rctr 4/, DaRCaJJte Special Instructions: /� Date W to a.m. '(7 — p.m. Requester: ,, i /j/ //,, 17popk. W ✓ t) kilt f if Phone No: 7-53 Z(-35.-/o Approved per applicable codes. Corrections required prior to approval. OMMENTS: -Fe(tAte by4 Inspector: Date - l'/ —r g REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 lK(s_Ot0 Project: V cctt/ck 5(& s__ Type of Inspection: PIAIe k _ A Address: 7 q 0 kir ? 4t (A • Date Special Instructions: /A A/`'1 Date ant d: 1� v J a.m. P.m Requester: Phone No: taApproved per applicable codes. 0Corrections required prior to approval. t Inspector: ti Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. re - INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro' ct: pp %%/�,,� ( �11L � j7 dcei / D �Q51.S� Type of Inspection F(�%j' s Address: fa� �`/� �I�`I ( Il3T 4.641c�V' ie — tut Date Called: Special Instructions: 4/1 Date Wanted: q- / G/ a.m. p.m. Requester: Phone No: EDApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: p//f Vc 9 ort 'ea' .P%&Cpt. or Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SHUTLER _ - CONSULTING ENGINEERS, Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425) 450-4075 FAX (425) 450-4076 JOB Prologis/Upland - HVAC Support SHEET NO. COVER OF CALCULATED BY MTN DATE 8/4/2015 CHECKED BY DATE SCALE JOB NUMBER 15-01.61 STRUCTURAL CALCULATIONS FOR: PROLOGIS/UPLAND - HVAC Support 1139 Andover Park West Tukwila, Washington MECHANICAL: Universal Refrigeration, Inc. PO Box 614 Auburn, Washington 98071 ph:(253) 939-5501 DESIGN CRITERIA: RECEV`D CITY OF TUKWILA AUG 0 4 2015 PERMIT CENTER ILE CODE INTERNATIONAL BUILDING CODE, 2012 Edition ROOF LIVE LOAD 25 PSF SNOW LOAD WIND LOAD 110 MPH ZONE, EXPOSURE "B" SEISMIC DESIGN INFORMATION Ss =144% SDs = 0.961 S1 = 54% SDI = 0.536 Ip=1.00 Rp=6.00 ap=2.5 SITE SOIL CLASS = "D" (Assum RISK CATEGORY = II REVIEWED FOR CODE COMPLIANC APPROVED AUG 14 2015 City of Tukwila BUILDING DIVISIO Vt1 SHUTLER CONSULTING ENGINEERS Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425)450-4075 FAX425)450-4078 50'-O" JOe PROLOGIS/Upland HVAC Support Tukwila, Washington SHEET NO SKS-1 CALCULATED BY MN SCALE ) "=19-0" OF DATE 8-4-15 Job No 15-01.61 (E) t 6Y4x31 BEAM RTU #1 WT=830# ,(E) 2x4 STIFFENERS ® 24"o.c. (TYP.) 6Yax31 BEAM 1 0 I N c 0 1 N PARTIAL ROOF FRAMING PLAN 1) VERIFY LOCATION OF UNIT WITH MECHANICAL DRAWINGS. 2) (E) DENOTES EXISTING. (N) DENOTES NEW. 0 co43 TT T r--1 AREA OF ..(1-BUILDING KEYS ENLARGED NO SCALE PLAN MMI .1111/11111110 SHUTLER CONSULTING ENGINEERS Inc. 12503 Bel —Red Road, Suite 100 Bellevue, Was n 98005 (425)450-4075 F425)450-4078 E) STIFFENER TYP.) —\ 80 (E) PURLIN (BEYOND) (E) BEAM PER PLAN NOTES: ALL EDGES OF ROOF TOP UNITS TO BE SUPPORTED BY 4x8, 4x14 OR 6Z" BM (E) SHEATHING (E) PURLIN PER PLAN Joe PROLOGIS / Upland HVAC Support Tukwila, Washington OF CALCULATED BY MN DATE 8-4-15 SCALE NOTED Job No 15-01.61 SECTION A/SKS-2 SCALE: W=1'-0" (N) 4x8 DF#2 BENEATH CURBS w/SIMPSON LUS46 HANGER EA. END MECHANICAL UNIT BY MECH. CONTRACTOR 2 #10 TEK SCREWS EACH SIDE OF UNIT (8 TOTAL) CURB PER MECH. CONTRACTOR (N) 2x LEVELING PLATE w/SIMPSON SDS25412 WOOD SCREWS CO 18"o.c. (MAX.) 2"(MIN.) PENETRATION (WOOD SCREW INTO STRUCTURAL MEMBER) (N) 4x8 DF#2 WITH LUS46 HANGER (E) BEAM PER PLAN SHUTLER CONSULTING ENGINEERS, INC. 12503 Bel -Red Road, Suite 100 Bellevue, WA 98005 (425) 450-4075 * FAX (425) 450-4076 JOB t r-!'!I1Ats/l[ Uf tAvto `w\ . ` ' , Oi2T SHEET No. f ,, 11"l CALCULATED BY tN OF DATE i r SCALE Wind and Seismic Forces on Drvcooler Unit Unit data: Unit base weight Economize Curb Total weight Weight used in calculations 665 i lbs. 50 lbs. 115; Ibs. 830 lbs. Width = 830. Ibs., to include duct work, etc. Seismic: Fp = (0.4*ap*SDs*Wp)*(1+2*(z/h))/(Rp/Ip) Fp = 398.815 lbs. <== Controls Fp(max) = 1.6*SDS*Ip*Wp Fp(max) = 1276.208 lbs. Fp(min) = 0.3*SDs*Ip*Wp Fp(min) = 239.289 Ibs Fp = 279.17 Ibs. (ASD) 4-- Wp= SDS= a = Rp = Ip = z=h=>z/h= Wind: (Section 29-5.1 of ASCE 7-10) Fh = qh*(GCf)*Af (Horizontal Force) Fv = qh*(GCr)*Ar (Vertical Uplift Force) qh = 0.00256*KZ*KZt*Kd*V` = Fh = 35.02 *Af PSF Fv = 27.65 *Ar PSF Fh = Fh = F„ = MOT = MOT = MOT = 18.43 PSF 518.27 Ibs.(Transverse Horizontal Force) ASD 329.17 Ibs.(Longltudinal Horizontal Force) ASD 400.64 Ibs.(Vertical Uplift Force) ASD 10236.25 in.-lbs. (Seismic) 12438.52 in.-Ibs. (Wind - Transverse) 7900.14 in.-Ibs. (Wind - Longitudinal) Load combinations: Case 10.60 Dead + 0.6 Wind Case II 0.60 Dead + 0.7 Seismic Transverse Seismic Hold Down Force = Longitudinal Seismic Hold Down Force = 27.66 Ibs UPLIFT -96.22 Ibs Unit Dimensions Height = 34: in. Length = 74: in. 47! in. 830 lbs. 0.961 2.5 6.0 1.01 1.00 Curb Dimensions Height = 14 in. Length = 67in. Width = 371 in. Basic Wind Speed 110 iMPH Exposure t B Average roof height 28.00 ft. Kz = 0.700 Table 30.3-1 Kd = ` 0.85Table 26.6-1 Kxt = 1.0 Section 26.8.2 (GCr) = Horizontal Gust Factor = (GCr) = Vert Uplift Gust Factor = Ar = Vert Proj Area (Transvese) = A = Vert Proj Area (Longitudinal) = Ar = Horizontal Projected Area = Hold down NOT req'd Transverse Wind Hold Down Force = 287.50 Ibs UPLIFT Longitudinal Wind Hold Down Force = 69.23 Ibs UPLIFT File:HVAC wind seismic.xls, modified 2-21-14 1.9 1.5 24.67 ft` 15.67 ft` 24.15 ft M cuto8 Design Maps Summary Report http://ehp3-earthquake.wr.usgs.gov/designmaps/us/summary.php?temp... MUM Design Maps Summary Report User -Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.45°N, 122.25°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III mapquest USGS-Provided Output Ss = 1.442 g S1 = 0.536 g SMs = 1.442 g SM1 = 0.805 g Sos = 0.961 g Sol = 0.536 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions In the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.45 1.50 1.35 1.20 1.05 0.9 0.75 0.60 0.45 0.30 0.15 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Period, T (sec) 2.00 1.10 1.00 0.90 0.80 0.70 S 0.60 a 0.50 0.40 0.30 0.20 0.10 0.00 Design Response Spectrum 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 Period T (sec) 1.60 1.80 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or Implied, as to the accuracy of the data contained therein. This tool Is not a substitute for technical subject -matter knowledge. 1 of 1 7/31/2015 9:08 AM SHUTLER _ CONSULTING ENGINEERS, INC. 12503 Bel -Red Rd, Sulte 100 Bellevue, WA 98005 (425)450-4075 FAX: (425)450-4076 J08 Lix'LtJ/LIF4Ar4O ✓u po 1. SHEET NO 3 CALCULATED BY HAI) OF DATE [J "3 -6 SCALE lam/ (.1C CI C) i { 1 - - C —.. +) 43/4111$ ...._._ i' el _ __.-...._..-.J.._...... __.._......... _ . _ 1 r I i _ _ __.... _ � — ....._-3 I� 1 I , f 1 •i I 1 • [ 1 I J . - .421 -71 . .. - i .._....... _�.y�.��j i -I� i j. ,P ... _— _ _,._.._._._. ..0 sie ...... -- —. __. ....I.__ — _._... _ _...__...__ C 4e — -- -- ___......__...__ I - -- ____� T -- _... m....._......._.._.._..._...__...--'--_._..._ — — __ _ _...._.__._-_.-----._....._____.........-------....___. --T -- -- —__ ............ ............... ........_ .....__ _.._ __...J.__._..._._._ .-_---_ • _------_ ._..._..._._...._. 1 , LE: 7 ! • i Q?. t,----• r i -,--, i idest it ' — — I _ — ti _.Ni-c F."I -- SHUTLER CONSULTING ENGINEERS, INC. 12503 Bel -Red Rd, Suite 100 Bellevue, WA 98005 (425)450-4075 FAX: (425)450-4076 i �If l!= �21....�Ib JDB I et7C11 / UPI A 4O 1VAC 5u4 Per SHEET NO 4 CALCULATED BY Ml•-•1 DATE 8 t5 SCALE N�� rti. (uLp ' - l . CurLC> T � A103 � pi t--- J I3 - 2. 3 * 3 1_W -�k ur, 1 .5� bL OF N 1274 - U--OtA.T T Z ; i .. 1.._..- 1�'I---- 5t5 t l' �IFD • ;• }S 1 .. L- I. 1 ; • f SHUTLER CONSULTING ENGINEERS, INC. 12503 Bel -Red Rd, SLAW 100 Bellevue, WA 98005 (425)450-4075 FAX: (425)450-4076 jos N01.0616/ LtriAlAD N/CC- .t.?t2e)et SHEET NO 5 OF CALCULATED BY DATE S —3 —LS SCALE 1 i 1 I 1 i , . --1 I i I —1— 1 ! r• i I I 7! [ 1 ' IL 1 • I I1i --T--- Alto /able Screw Connection Capacity (Ibs) ' _ ____. • • .-G7,...:.•.1 - ,: ..• con-ua..- .• .. I .- .. -,5F•filmzi --_L .,- • .. , f.',01L-7, - ' .• • . .tm.-217,77 • ' --- ---1 -- - in ii,,,D;...,,i,.%.,11:3,,,r, Iii*q. .1-0-fritili. 1 ,r,,;..Wrcc. i'laprL3 (#'7,41:i1L.L....it.gral_llh 011aSykir4;-1,0,1j. ,-11•:17.,1:7,51p — ..--- ---- ' 1'''11r1) F4.1•'•11'.' 7-4C-irq114(4. 1_164' -;-14-14alkill ; ;;EAC -2--.6.1.,,-14a-i-,-c- - - -- -,:-.- ; - - .. - '.... - ..• ,.,,.: I , 4.00 top?* FAg,p! ,,igh-iiir,d ot4v51 00:•!ii...it :1-_...,.4f: R4f. igi?ii- '...644 pit 1 - --- ' — 2.-2r118 30 0.0168 Rig.1Z-faL741:53f7 ' 0.03 2 33 93 13 93 44 1!-A2!64 85 24 !f;17In;,‘1 40 84 1!;TI27;f:- 140 8 ti2()1.g • 103 29 Z41.1*..1 48- 84 7Ift-tli 40 52 33 !-1.1)WiCi tfE3;i7i . 105 4.,WA§Ji 175 iiiii ::t. 65 .4" 1 35 ,.fil105 60 .127 - :'f" .,f21-$9:45 '.••f:;tf0.V.! 63 176 127 ?all:7, 211 - - I r I 1.4:;•4111349513_131332:ittittl ''''n•ea0.071933 1`:-'6'045507-1'"s1,7'4•4.1$:' '''nrtial1.1 'fit.4:19 n''214 ''n '.i,'Il%S'‘q' .:Mtio '•11,14F'': 11 'zifir' !.:L1444 ...i ;.:-t4:0 1M-;14?f. tedf.G i::14111,z, ;'11$TA ;•.••.17437_,N :_,-,ilt19:x7.-FMA ''IN': j.t,'45r.F: ,•*:184).74t Z1:8)I; $4l';.7;f' kief1254,-,5 tlri'0 !.23:52f'i 410 lirel '...' ,'.glsift=', P.4i.if! i'lf,14', 2f:, On ,402r;:li - • 1 i 1 _._.. ...... _.. ..'4 el:-S.,i'0710171-4"if_ii:r1.4:57.%4 118 n • • 45 -' 39 45 :,<,'EtitiN 214 125 L.140-:•"11 140 n'' • 140 n '.;'Atr:j. 140 426 .i..-.42fi.ii 426 149-195 90.6k. 195 ' WO) 195 n 523 173. 2.,00:,!i 1:1:.g)-R 648 301 n • 388 ,a08:: 988 '-557 ;e777'fir; 777 '' • :-1913:- .545 660 227 nn. 156 - ;igeo:i:_f f',ItC6! '',1,0.1.47 '',32iffLi ii.Pfli 942 775 16 396 ; - -1----1" ! - - I I • 61'""I'-221."'-'11'''712." ,': 97 113 .. .0.1242 .. ;.::-.0017;!•• 0.1242 . r:;-; 50 ;. :!'.85 J.': 50 65 6111'" •::'214 '.• 214 "It' ',".140 140 . '''11:*" ;:i %:,140 14 '":1:''' r..-'425 E 428 '"1-7ik''' :',105.', 1 .1:555c ':105.. 195 -114,- '711::;" 048 ;. ;. 358 .. 548 , '"'13E8.r -;,•388 ,,. 388 :nv' :W.:- . . ,1 . ;1067 '..,tir,..'' .,.'1,g,, ,,1136i'' .'"IF ' ' 21 !!."405 4 -:. 775 ;.. 1816 ., 468 . ::'1,857.,/ 494 775 1016 572 1067 • .- I ---- - " - ' --1- - L. I '--- 1 i! 1 ! i , , 1 I , t 1 --i-- I 1 i , 1 SIMpSOD 1 Strong-Tiee 1 1 Strong-Drive°SDS 1 f HEAVY-DUTY 1 CONNECTOR 1 Screw , i and Water 1 I -Head Screw , __, , , f 1 — ! -3 i , I 1. ii l• _ ...,,...::• :, ,.:,•,...• ....,,: •ii. '..•••,:• • --;-,.. .•••.•.; •••:,:::::-.f.•,::::::::::::::::AjFicp•mawahhitaidai.:::,•::::::::::::;•,:•,, • .-. •:•,.::: ;"•.,:gptiloAddwahiquadas,...- • ....;:- y!; ...:. .!.:- - ._. _ _ -- ! • .... - " ' 3178 • . Mattel- Thread Fasteners .-:,:••.:::::••::::•.,:::::lheirkteep::::;•:;::::::-.:i::::::::. ivithdraWay - ..-• • .- ;,.....•.•stwar(ion) ,. ,. • ,...;: •... withdraw? .ii-de, • L. 1 .01.16;•:•.i.•!,i !?9,19,Illi, •',11.!1,1• Wocceice 1100 ..;:8 01.010110e;,(,::..:•,::..P99.:;i:x: woo; ONO h1,4;13C8Iejdo.100....;;;1(199).:ii:i:ii . , . . .1 .. ... . . );-"IIIIIIY; 1'a -iiI:tglit:'7,-A e44. •,40,,P,:.5.:.,n, StY4OII•1 •••• t;Oobei&' 1-e0.0iiii• W,IiliidfddilsifffSiltDrell. P:..1a..i.4ti: a#Ca1,Ve lV, l0o4t-aiifjkq wifitomio 40100•Kiitim tali Mi, • ,• sc: x ut S083(1.251 - - - - 60 60 60 - - . - 45 45 45 - 170 : ! 16x114 SDS25112 1 1500 - - 250 250 250 170 - - 180 180 180 120 ID •1/4Yi'2'4 SDS25208 iilive iz)1806N 'f•,.4":, '::.',.:-7,i 25-6 •,t-g.V: ::::.200'i '...;.-.::-21.5j. i':': '444 5100 ii210tA' .,E;I:10-4: {K-T115tiLFR, _ NI Y. g% 99925212 1;114 :-.; 91100 1,; ,1611..- :;;;;4:;;; :250. :390:. 1:;*429.: 5::;.: ii135f, .:1....;.::.; law :::280.,. Joo;', !..1180.:6;-::. ----1-------- i...- -- 1. 15)(3 SDS25300 2 950 280 - 250 420 420 345 200 - 180 300 900 240 15, 1 1 __ .. . Il 1/4 x 31/4 SDS25312 21/4 900 340 940 250 420 420 985 245 245 180 300 300 270 L1, 4,._ ', 1.1 05x454 S0S25412. :25.i.„ •:;-.5904:., ;.:350 340 ... :258 :420.. -:: ... -:. :::::,1175.:..... : ;150 ,,,•245,, 180.. ....$00 ,, -308., ,:.1..,•330.r,- F20 ; i le '..:suig,I. s0525500 ..2y.i,i :.4,509:;,;i ....:150 .:: _NO ,. .24.0 :::420:: ...420 •i• :.•:•••1:47$,. •:: :250i )7245.:: 180., :.300 .i .;.,300. '. :1330 ,!:,;•:. [ . Nilti. S0S2500 ,It'A 4:§(19:34 :::350i a340:fi! 2O,,:1420: :;:,420;:i 'i-fi::V560;..,:i* ,12601-.1 42402 ...i1801 .`300.1 asolin 4,4.g995dIAFil 1111 14x8 50825800 31/4 400 •f•.450-? P400.4 -'Ipq, il,.420) •i!420:•, ?S..860.:r. 1,:jM9:2 .144.0.3,7 41h4i Ofiti...it if3010..g 1!-M39.5..1.47.4 1 1 - : -1 . r ..___ T 1- _i_. , 1- I --I- i. i i i ..... I 1 I i 1 . 1 1 I 1 i 4 ; . i _I_ I i I i I -1 ---` i I -4-- i 4 I 1 1 1 T I 1 I I I .----r- 1 ----+- i ! 1 , Jr--- _L. i-- r i . I •-i 1 T- i 1 . + I - 1 I --1- i I i I I I i• I I l r i I _111111 SHUTLER �- CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB ?OW/ LIt% YD tt\��.�I parr SHEET NO. OF tl CALCULATED BY DATE 6 -3-6 SCALE C3 t. A SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 ?40 (4 4 .fit ,e r � )ct) Pr d k t$D.9 r ONL • Did ►'� 3b.(06'4I Gt G 5 -15 (I /2 3cs - 31'26 • t< list Tlf fL4r 1. rn rut jojiblIANbi U?1 t t-W4C SLuepoeT SHEET NO. 01.1 1 ,, I CALCULATED 8Y MI.1 OF DATE 6-3-6 SCALE 1.1-1-5 (Mc- tev .b+ G sp* S 1 o1,tW 4A-1- ' Lws2lo .0 n =10� w (.1. = 1-50F Lea 2bb(�`�= b{ lobo( 4= lQ V eel -5 I 40 LtzV3o p L• l5kZ//3bb���`�i�,� 4x IIt V62- o 6 1*Z 3.c4*'rr sd Vrr et. oil- e llZb psi ok 6 REF-1 and 2 NuTone Architectural & Engineering Specifications December 2007 DESCRIPTION BLOWER: • Plug-in, permanently lubricated motor - engineered for continuous operation • Dynamically balanced centrifugal blower wheel for quiet, efficient performance • Low RPM for quiet operation • Resilient anti -vibration motor mounts HOUSING: • Rugged, 26 gauge, galvanized steel construction • Polymeric, 4" round duct connector with tapered sleeve and no metallic clatter • 7-5/8" height allows for 2" x 8" (nominal) joist installations • Sturdy, easy, four -point mounting directly to joist • Includes unique spacer (patent pending) for mounting to engineered "I" joists • Can be mounted in ceilings up to 12/12 pitch GRILLE: • Polymeric construction • Innovative design - the result of extensive research with designers and consumers BUILDER PACKS: • Model QTRNO5OF includes blower and grille only (packed 1 per carton) • Rough -in housing required - order NuTone Model QTXRN000HF (4 housings per carton) - Includes hanger bars to position housing anywhere between 16" to 24"-on-center joists (4 sets of hangers per carton) - Two sets of mounting holes for hanger bars allow flush installation with bottom or top of drywall CONTROLS (Purchase separately): • Refer to NuTone's catalog for a complete line of accessories to effectively adapt these fans to your construction requirements. U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit (ceiling mount only). 3-Year Warranty INSTALLATION 2100 HVCERTI ILE QTRN Series Fans MODELS QTRN050F, QTRN080, QTRN110 ARCHITECT'S SPECIFICATION • Ceiling Ventilator shall be NuTone Model QTRNO5OF (QTRN080) (QTRN110). • Ceiling Ventilator shall have corrosion resistant galvanized steel housing with four -point mounting capability. It shall be ducted to a roof or wall cap using 4" round ductwork. • Blower assembly shall be removable, have a centrifugal -type blower wheel and a permanently lubricated motor designed for continuous operation and mounted with resilient anti -vibration mounts. • Non-metallic damper/duct connector shall be included. REVr o g h CODE C@MPIA* 1 APPROVIZOthator s all be U.L. List o e 96trrliathtubs and showers when con ected to a Ittt:Jd'6r&ch circuit. CITY OF TUKWILA Complete installation instructions are included with each n. Broan-NuTone LLC Hartfor AUG 14 2015 no less than 50 (80) (110) CFM and sound n 0.4 (1.0) (1.5) Sones. All air and sound fied by HVI. AUG 0 4 2015 ,E4116.0INGANIMON 888-336-PERMIT CENTER City of Tukwila REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date ¥AV.olDm 99044088A ) PERFORMANCE RATINGS QTRN SERIES FANS HVI PERFORMANCE Model Sones @0.1"Ps CFM @0.1"Ps QTRNO5OF 0.4 50 QTRN080 1.0 80 9TRN110; 1.5 110 2100 HVI CERTIFIED AMPS HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off -the -shelf products, as they are available to consumers. Product performance is rated at0.1 in. static pressure, based on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure of humanly -perceived loudness, based on laboratory measurements. Model Amps QTRNO5OF 0.3 QTRN080 0.7 (QTRN110; 0.9 WEIGHT Model Shipping Weight QTRNO5OF 5.9 Ibs. QTRN080 10.6 lbs. ;QTRN110 10.6 Ibs. NuTone AIR FLOW PERFORMANCE 0.6 0.5 di 0.4 • 0.3 a 0.2 0.1 0.0 0.9 0.8 0.7 oi 0.6 0.5 O 4 0.3 0.2 0.1 0.0 0 MODEL QTRNO5OF 10 20 30 40 Airflow (cfm) MODEL QTRN080 50 60 70 0.9 0.8 0.7 0.6 0.5 C 0.4 a 0.3 0.2 0.1 0.0 0 10 20 30 40 50 60 Airflow (cfm) 'MODEL QTRN110 70 80 90 100 10 20 30 40 50 60 70 Airflow (cfm) 80 90 100 110 120 Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948 Co United Technologies SUBMITTAL Project -Untitled 10 Date Monday, July 27, 2015 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 4 2015 City of Tukwila BUILDING DIVISION FILE RECEIVED CITY OF TUKWILA AUG 0 4 2015 PERMIT CENTER WA19.0101 Table Of Contents Project: -Untitledl0 Prepared By: 07/27/2015 04:04PM 3tongaspk 3 Unit Report 4 Certified Drawing 5 Performance Summary 9 Unit Feature Sheet 12 Spec Sheet 13 (-E1 1 t L Packaged Rooftop Builder 1.39r Page 2 of 13 3 ton gas pk Project:-Untitledl0 Prepared By: 07/27/2015 04:04PM 3 ton gas pk Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.39r Page 3 of 13 Unit Report For 3 ton gas pk Project:—Untitledl0 Prepared By: 07/27/2015 04:04PM Unit Parameters Unit Model. 48KCDA04A2A5-0A0A0 Unit Size. 04 (3 Tons) Volts -Phase -Hertz. 208-3-60 Heating Type. Gas Duct Cfg• Vertical Supply / Vertical Return Low Heat Single Stage Compressor Models Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity. 2 Return Air Filter Size• 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) ""' Unit Length. 6' 2.375" Unit Width. 3' 10.75" Unit Height. 2' 9.375" **• Total Operating Weight. 665 Ib "' Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA04A2A5-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive None Accessories CRECOMZR020A02 Standard Leak Vertical EconoMi$er IV with solid-state controller 1 CRRFCURB001A01 14-inch Tall Roof Curb 1 Packaged Rooftop Builder 1.39r Page 4 of 13 Certified Drawing for 3 ton gas pk FIELD POWER SUPPLT ROLE ER SUPPLY KNOCKOUT GAUGE ACCESS PLUG 3/4'-14 NPT CONDENSATE DRAI 1/2'-14 NPT GAS CONNECTION 2 1/2 ' I641 DIA POWER SUPPLY KNOCK -OUT gitE RAI coW 0 712 s 0 sW 111111111111111111111111111111111 IIIIIIIIIIIIII IIII 111111111111111111111111 111111111111111111 MIIII' 1111111111111111 11111 !IIIIIIIIIIIIIII o 0 1 II IIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIII IIIIII IIII IIII o cc La- 48KC000281 acC LC W� W� Packaged Rooftop Builder 1.39r Certified Drawing for 3 ton gas pk 0 1-2 CC 0 V V CC O V 0 a •:oo I' •i 'fi': : oo 111111111111111111111111111111111 111111111111111111 111111111111111111111111 111111111111111111111111 111111111111111111111111111111111 1111111111111111111111111 48KC000281 v CC 0r w Page 6 of 13 Packaged Rooftop Builder 1.39r Certified Drawing for 3 ton gas pk oa N 0 •• 0 0 G) c >, D m v G) U G) G) a. O G) as A Service Clearance 11111 4IP...1X i,. I 4., ,. ,,,,,, 038337 z 0 • Unit disconnect is mounted on panel • No disconnect, convenience outlet option • Recommended service clearance • Minimum clearance •Surface behind serviceris grounded (e.g., metal, masonrywall) •Surface behind servlceris electrically non-conductive (e.g., wood, fiberglass) •Check for sources afflue products within 10- ft. of unit fresh air intake hood • Side condensate drain is used • Minimum clearance • No flue discharge accessoryinstalled, surface Is combustible material • Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) • Surface behind servlcer is electrically non-conducthre (e.g., woodfiberglass) • Check for adjacent units or building fresh air Intakes within 10- ft. of this unit's flue outlet NO7E: Unit not designed to have overhead obstruction. Contact Application Engineering for guidance on any application planning overhead obstruction or vertical dearances. F 0 u V E E- 48-In (1219 mm) 42-In (1067 rim) g E�E�E E l' N a P.,2 it' a" A 0 e c c e e .. e z 0 Q Q m u 0 Packaged Rooftop Builder 1.39r Certified Drawing for 3 ton gas pk 11 R$ W LLI kr a 1 N4, i I i $15 a I i Packaged Rooftop Builder 1.39r Performance Summary For 3 ton gas pk Project:—Untitledl0 Prepared By: 07/27/2015 04:04PM Part Number:48KCDA04A2A5-0A0A0 ARI SEER• 14.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width. 46.8 in Unit Height. 33.4 in Operating Weight Base Unit Weight 490 Ib Medium Static Option Belt Drive- 10 Ib Accessories Standard Leak Vertical EconoMi$er IV with solid-state controller 50 Ib 14-inch Tall Roof Curb• 115 Ib Total Operating Weight- 665 Ib Unit Unit Voltage -Phase -Hertz 208-3-60 Air Discharge. Vertical Fan Drive Type• Belt Actual Airflow- 1200 CFM Site Altitude. 449 ft Cooling Performance Condenser Entering Air DB• 85.0 F Evaporator Entering Air DB• 79.2 F Evaporator Entering Air WB• 64.4 F Entering Air Enthalpy• 29.63 BTU/Ib Evaporator Leaving Air DB• 56.2 F Evaporator Leaving Air WB• 54.1 F Evaporator Leaving Air Enthalpy. 22.75 BTU/Ib Gross Cooling Capacity. 36.60 MBH Gross Sensible Capacity. 29.26 MBH Compressor Power Input 2.59 kW Coil Bypass Factor 0.119 Mixed Air Outdoor Air Airflow. 420 CFM Outdoor Air DB• 85.0 F Outdoor Air WB• 65.0 F Outdoor Air Htg. Temp • 23.0 F Return Air DB• 76.0 F Return Air WB• 64.0 F Return Air Htg. Temp • 70.0 F Heating Performance Heating Airflow: 1200 CFM Entering Air Temp• 53.6 F Leaving Air Temp• 97.5 F Gas Heating Input Capacity 72.0 MBH Gas Heating Output Capacity. 0.0 / 56.0 MBH Temperature Rise- 43.9 F Supply Fan External Static Pressure. 0.50 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$er2• 0.04 in wg Total Application Static (ESP + Unit Opts/Acc.)• 0.54 in wg Fan RPM• 850 Packaged Rooftop Builder 1.39r Page 9 of 13 Performance Summary For 3 ton gas pk Project:-Untitledl0 Prepared By: 07/27/2015 04:04PM Fan Power 0.44 BHP NOTE Selected IFM RPM Range: 770 -1175 Electrical Data Voltage Range- 187 - 253 Compressor #1 RLA• 10.4 Compressor #1 LRA• 73 Outdoor Fan Motor Qty 1 Outdoor Fan FLA (ea)• 1 Indoor Fan Motor Type• MED Indoor Fan Motor FLA• 5.2 Combustion Fan Motor FLA (ea)• 0.48 Power Supply MCA• 20 Power Supply MOCP (Fuse or HACR)• 25 Disconnect Size FLA- 19 Disconnect Size LRA• 111 Electrical Convenience Outlet None Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 83.6 85.5 78.2 125 Hz 76.3 73.6 78.0 250 Hz 66.0 59.1 74.2 500 Hz 62.6 58.8 73.3 1000 Hz 59.3 58.5 70.6 2000 Hz 53.7 52.5 66.0 4000 Hz 54.8 47.3 62.4 8000 Hz 49.0 38.9 56.9 A -Weighted 66.7 64.6 76.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground• 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.39r Page 10 of 13 Performance Summary For 3 ton gas pk Project:-Untitledl0 Prepared By: 07/27/2015 04:04PM Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 78.2 78.0 74.2 73.3 70.6 66.0 62.4 56.9 82.9 Lw B 52.0 61.9 65.6 70.1 70.6 67.2 63.4 55.8 75.4 LwA C 45.8 45.6 41.8 40.9 38.2 33.6 30.0 24.5 50.5 Lp D 19.6 29.5 33.2 37.7 38.2 34.8 31.0 23.4 43.0 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 23 18 16 04 02 CO 00 03 06 Q3 12 15 AiAbw(CFM-thousands) RPM=850 BHP=0.44 MaxunumRPM=1175 MaximumBHP=2.90 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC- System Curve RP-RatedPoint 18 FanCurve 100RPAA \ ` , \ 13ooRPM \ \ 15XRPM \ \ 3.o0BHP _ 900RPM ` \ - i `\\ - 700RPM AillL\ \ - .14111iiiii._o.7�BHP \ -I BHP\ 1.00BHP \ ,o SoaHP 21 24 Packaged Rooftop Builder 1.39r Page 11 of 13 Unit Feature Sheet for 3 ton gas pk Project:-Untitledl0 Prepared By: 07/27/2015 04:04PM ASNRAE{ COMPLIANT Carrier WeatherMaker' — 48KC PACKAGED ROOFTOP GAS HEATINGIELECTRIC COOLING UNITS -14 SEER 0 Puron. 3, 4, 5 TONS WEATHERMAKER SERIES WeatherMaker 48KC (14-SEER) units are one-piece gas heating, electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factory tested in both heating and cooling modes, and rated in accordancewith AHRI Standards 210240. WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certified by: A• CERTIFIED- US Certified to ISO 8001 STANDARD FEATURES INCLUDE: • !Puron (R-410A) HFC refrigerant • Meets and exceeds ASHRAE 90.1 energy efficiency levet • Scroll compressors with internal fine break and overload protection • Single -stage cooing capacity control • SEER'supto14.0.EER'supto12.0 • Acutrol" refrigerant metering system • Exclusive non-conosne composite condensate pen in socordance with AS.HRAE Standard 62. sloping desgn, side oreenterdrain • Standard cooing operation up to 1157(46`C)and down to 40°F (4°C) - down to 25' F (-4• C) with winter start kiL • 'Pre -panted exteriorpanetsend primer-coeted nteriorpanettested to 500 hours salt spray protection • Fully insulated cabinet • Exclusive IGC sold -state control for on -board diagnostic' will LED error code designation bumercontrollogic end energy saving indoor fan motor delay • Low tiOx models that meet Ceifomie Air Quaky Management • Induced draft gas heat combustion desgn • Redundant gesvalves withuptotwvostagesofheating • Low pressure end high pressure sitcti protected. MAINTENANCE FEATURES: • Access panels with easy grip handles • Innovative easystarting, no -strip screws on unitsocesspanels • Two-inch disposable return skaters and Tool4ess fitter amass door • Direct Drive -ECM ndoormotor. standard with optional bek drive systems • Terminal board facilitating sample safety circuit troubleshooting and simplified control box arrangement • Exclusive IGC soid-state control for on -board diagnosticswab LED error code designation, burner control logic and energy saving indoor fan motor delay. INSTALLATION FEATURES: • Thnu-the-bottom power entry cepabity • Single point gas and el ectricconnections • Full perimeter base ref withbuit-n rigging adapters and fork slots • Field convenble from vertical to horizontal airflow STANDARD WARRANTY: • 10-yearheatexchanger— 15-yearstaintesssteel option • 5-year compressor • 1-yearpads • Many optional upgrades also available OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Premaert.nk and RTU Open Multi Protocol DDC Controls • Supply and Return Air Smoke' Detectors. high static motors • Louvered condensercoiguards • Disconnect switch and convenience outlet options • Stainless Steel heat exchanger option • Corrosion resistant col coating. • ligh steticmotor options • Patented Humidi- iZee adaptive dehunidtfication system. This option also ncludesMotormester I controls • hinged access panels • Integrated econonezersystern. Standard and Ultra Low Leak versions For a complete fist of options and accessories referto the Product Data Catalog for this unit. Packaged Rooftop Builder 1.39r Page 12 of 13 Spec Sheet for 3 ton gas pk Project:-Untitledl0 Prepared By: 07/27/2015 04:04PM Packaged Rooftop Builder 1.39r Page 13 of 13 1/1,ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0101 DATE: 08/05/15 PROJECT NAME: PROLOGIS - UPLAND TI SITE ADDRESS: 1139 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division '" Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/06/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/06/15 Approved Corrections Required Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 UNIVERSAL REFRIGERATION III Page 1 of 2 Horne Irricio en Espanol Contact. Search L&I A-Z Index Help My Secure I: &I Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries UNIVERSAL REFRIGERATION INC Owner or tradesperson Principals GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. 600 599 723 PO BOX 614 AUBURN, WA98071-0614 253-939-5501 KING County Business type Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..................._................................_.................... Meets current requirements. License specialties COMMERCIAL/INDUSTRIALIREFRIG License no. UNIVERI159RF Effective — expiration 12/06/1985— 04/01/2016 Bond ................. AMERICAN STATES INS CO Bond account no. EX903622 $6,000.00 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance ........._..._........... American Economy Insurance Co $1,000,000.00 Policy no. 01 C179965210 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 8/19/2015