HomeMy WebLinkAboutPermit M15-0101 - PROLOGIS - UPLAND TI - ROOFTOP PACKAGE UNIT, EXHAUST FANS, VENT ETCPROLOGOS -UPLAND TI
1139 ANDOVER PARK W
M15-01O1
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
3523049102
1139 ANDOVER PARK W
Project Name: PROLOGIS - UPLAND TI
MECHANICAL PERMIT
Permit Number: M15-0101
Issue Date: 8/19/2015
Permit Expires On: 2/15/2016
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
AMB PROPERTY CORP
60 STATE ST STE 1200 C/O RE TA ,
BOSTON, WA, 02109
HEATH HAMBLEN
4102 B PLACE NW , AUBURN, WA,
98001
UNIVERSAL REFRIGERATION INC
4102 "B" PL NW , AUBURN, WA, 98001
UNIVERI159RF
Phone: (253) 939-5501
Phone: (253) 939-5501
Expiration Date:
DESCRIPTION OF WORK:
INSTALL (1) ROOFTOP PACKAGE UNIT AND AIR DISTRIBUTION SYSTEM. INSTALL (2) CEILING EXHAUST FANS AND
VENT THRU ROOF. NATURAL GAS PIPING FROM EXISTING MAIN LINE.
Valuation of Work: $16,018.00
Type of Work: NEW
Fuel type: GAS
Fees Collected: $415.74
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
Date:
2014
2014
2014
2012
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
i�7 //
Signature: r
Print Name: 6V(4, J�(I
Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: ***MECHANICAL PERMIT CONDITIONS***
9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. MIS • O` 01
Project No.
Date Application Accepted: �0 14I
/�(
Date Application Expires: ' (/ ((%
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address: 113q A„IboiJrra. i'AiLL Wbb�
Tenant Name: PKoiod;�S - [p(Anft,T T
PROPERTY OWNER
Name:
�ac(osis ic, .
t
Address: 12. 120 (10.1-etaA \%-DaIv'te tSJik II()
City►-Tvl. 1 iA tate: ta5K Zipt 1
CONTACT PERSON - person receiving all project
communication
Name: Shane (Heat Bryan Chuck
Address: 4102 B P1 NW
City: Aubum State: WA Zip: 98001
Phone: (253) 939-5501 Fax: (253) 735-3432
Email: @universalrefrig.com
King Co Assessor's Tax No.: Usso4- q 10`L
Suite Number: 4 fA Floor:
New Tenant: 2. Yes ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Universal Refrigeration
Address: 4102 B P1 NW
City: Auburn State: WA Zip: 98001
Phone: (253) 939-5501 Fax: (253) 735-3432
Contr Reg No.: UNIVERI 159RF Exp Date: 04/01/2014
Tukwila Business License No.: $(JS - o j 31 ztf
00
Valuation of project (contractor's bid price): $ 1LP1 1 • 11 ` tt
Describe the scope of work in detail: �Nst.4 ( 124 (.o� �A�ZtiG�Q Jr1iA ,,16 Ai
R UiS�,2lOJ�ioa stisLvot
�a5�a►1i (23 (.0;,sty syiett eJ- Wit, v6,41-460 czo4. 11, 1 cr
v.A.k: fa 1: nit,
Use: Residential: few ❑ Replacement ❑
Commercial: New Q'
Replacement
Fuel Type: Electric ❑ Gas E 1'
Other:
H: Applications\Fomts-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace > l 00k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
I
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Z
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in'writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNEBO; . ' . , IZED AGENT:
Signature: l
Date: 813f IS
Print Name: Day Telephone: (253) 939-5501
Mailing Address: 4102 B P1 NW Auburn WA 98001
H:\Applications\Fonns-Applications On Line\201 I ApplicationsVvlechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
City State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT QUANTITY PAID
PermitTRAK $628.81
EL15-0671 Address: 1139 ANDOVER PARK W Apn: 3523049102 $86.31
ELECTRICAL $82.20
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$82.20
TECHNOLOGY FEE $4.11
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$4.11
M15-0101 Address: 1139 ANDOVER PARK W Apn: 3523049102 $415.74
MECHANICAL $399.75
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$287.30
PLAN CHECK FEE
R000.322.102.00.00
0.00
$79.95
TECHNOLOGY FEE $15.99
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$15.99
PG15-0089 Address: 1139 ANDOVER PARK W Apn: 3523049102 $126.76
GAS $121.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.38
TECHNOLOGY FEE $4.88
TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.88
TOTAL FEES PAID BY RECEIPT: R5872 $628.81
Date Paid: Tuesday, August 04, 2015
Paid By: UNIVERSAL REFRIGERATION
Pay Method: CHECK 49787
Printed: Tuesday, August 04, 2015 3:57 PM 1 of 1
r' rIffSYSIEMS
1191
INSPECTION RECORD
Retain a copy with permits ®(a/
INO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-3670
Pro' ct:
Type of inspection: c
Idea( Fr ram.
-I. V
Ad ress.
l (35. ` .'G Lies- ?art_ck1
Date Called:
Special Instructions:
rIo—cr—or
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
7.q,
Approved per applicable codes. LJ Corrections required prior to approval.
LCOMMENTS:
Inspector:
Date:(--c(- r (---
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
icc
rINSPECTION RECORD
OA Retain a copy with permit
INS INO.
itittr-0 is
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila: WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-3670
Pro t:
uce
Type_of Insspscction:fart
In'_l�(i`
'
Address:
1(3 « (otitr ('ur�l
'r ,
Date Called:
Special Instructions:
)�A
Date Wanted:
(0-0- (S
a.m.
p.m.
Requester:
Phone No:
Approved per applicable codes.
COMMENTS:
tc
fff/i
�
(ot r � t
rb f felt. ,'ers4 (`c
Corrections required prior to approval.
A
C
Inspector:
Datea4 --b ,- f r
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
ket
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350m
Pr•
"%o"��efc'�t: ��
I
Type of Ins ection: ,` I
''v\
Address:
1(3 1 /1�JoVQr rctr
4/,
DaRCaJJte
Special Instructions:
/�
Date W to a.m.
'(7 — p.m.
Requester: ,, i /j/ //,,
17popk. W ✓ t) kilt f if
Phone No:
7-53 Z(-35.-/o
Approved per applicable codes. Corrections required prior to approval.
OMMENTS:
-Fe(tAte by4
Inspector:
Date - l'/ —r g
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
IN ECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
lK(s_Ot0
Project: V
cctt/ck 5(& s__
Type of Inspection:
PIAIe k _
A
Address:
7 q 0 kir ? 4t (A •
Date
Special Instructions: /A
A/`'1
Date ant d: 1�
v J
a.m.
P.m
Requester:
Phone No:
taApproved per applicable codes. 0Corrections required prior to approval.
t
Inspector: ti
Date
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
re -
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro' ct: pp %%/�,,� (
�11L � j7 dcei / D �Q51.S�
Type of Inspection
F(�%j' s
Address: fa� �`/� �I�`I (
Il3T 4.641c�V' ie — tut
Date Called:
Special Instructions:
4/1
Date Wanted:
q- / G/
a.m.
p.m.
Requester:
Phone No:
EDApproved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
p//f Vc 9 ort 'ea' .P%&Cpt.
or
Inspector:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
SHUTLER
_ - CONSULTING
ENGINEERS, Inc.
12503 Bel -Red Road, Suite 100
Bellevue, Washington 98005
(425) 450-4075 FAX (425) 450-4076
JOB Prologis/Upland - HVAC Support
SHEET NO. COVER OF
CALCULATED BY MTN DATE 8/4/2015
CHECKED BY DATE
SCALE
JOB NUMBER 15-01.61
STRUCTURAL CALCULATIONS FOR:
PROLOGIS/UPLAND - HVAC Support
1139 Andover Park West
Tukwila, Washington
MECHANICAL:
Universal Refrigeration, Inc.
PO Box 614
Auburn, Washington 98071
ph:(253) 939-5501
DESIGN CRITERIA:
RECEV`D
CITY OF TUKWILA
AUG 0 4 2015
PERMIT CENTER
ILE
CODE INTERNATIONAL BUILDING CODE, 2012 Edition
ROOF LIVE LOAD 25 PSF SNOW LOAD
WIND LOAD 110 MPH ZONE, EXPOSURE "B"
SEISMIC DESIGN INFORMATION Ss =144% SDs = 0.961
S1 = 54% SDI = 0.536
Ip=1.00
Rp=6.00 ap=2.5
SITE SOIL CLASS = "D" (Assum
RISK CATEGORY = II
REVIEWED FOR
CODE COMPLIANC
APPROVED
AUG 14 2015
City of Tukwila
BUILDING DIVISIO
Vt1
SHUTLER
CONSULTING
ENGINEERS Inc.
12503 Bel -Red Road, Suite 100
Bellevue, Washington 98005
(425)450-4075 FAX425)450-4078
50'-O"
JOe PROLOGIS/Upland HVAC Support
Tukwila, Washington
SHEET NO SKS-1
CALCULATED BY MN
SCALE ) "=19-0"
OF
DATE 8-4-15
Job No 15-01.61
(E)
t
6Y4x31 BEAM
RTU #1
WT=830#
,(E) 2x4
STIFFENERS
® 24"o.c.
(TYP.)
6Yax31 BEAM
1
0
I
N
c
0
1
N
PARTIAL ROOF
FRAMING PLAN
1) VERIFY LOCATION OF UNIT
WITH MECHANICAL DRAWINGS.
2) (E) DENOTES EXISTING.
(N) DENOTES NEW.
0
co43
TT T
r--1
AREA OF
..(1-BUILDING KEYS ENLARGED
NO SCALE PLAN
MMI
.1111/11111110
SHUTLER
CONSULTING
ENGINEERS Inc.
12503 Bel —Red Road, Suite 100
Bellevue, Was n 98005
(425)450-4075 F425)450-4078
E) STIFFENER
TYP.) —\
80
(E) PURLIN
(BEYOND)
(E) BEAM
PER PLAN
NOTES:
ALL EDGES OF ROOF TOP
UNITS TO BE SUPPORTED
BY 4x8, 4x14 OR 6Z" BM
(E) SHEATHING
(E) PURLIN
PER PLAN
Joe PROLOGIS / Upland HVAC Support
Tukwila, Washington
OF
CALCULATED BY MN DATE 8-4-15
SCALE NOTED Job No 15-01.61
SECTION A/SKS-2
SCALE: W=1'-0"
(N) 4x8 DF#2
BENEATH CURBS
w/SIMPSON LUS46
HANGER EA. END
MECHANICAL UNIT BY
MECH. CONTRACTOR
2 #10 TEK
SCREWS EACH
SIDE OF UNIT
(8 TOTAL)
CURB PER MECH.
CONTRACTOR
(N) 2x LEVELING
PLATE w/SIMPSON
SDS25412 WOOD
SCREWS CO 18"o.c.
(MAX.)
2"(MIN.) PENETRATION
(WOOD SCREW INTO
STRUCTURAL MEMBER)
(N) 4x8 DF#2 WITH
LUS46 HANGER
(E) BEAM PER PLAN
SHUTLER
CONSULTING
ENGINEERS, INC.
12503 Bel -Red Road, Suite 100
Bellevue, WA 98005
(425) 450-4075 * FAX (425) 450-4076
JOB t r-!'!I1Ats/l[ Uf tAvto `w\ . ` ' , Oi2T
SHEET No. f ,, 11"l
CALCULATED BY tN
OF
DATE i r
SCALE
Wind and Seismic Forces on Drvcooler Unit
Unit data:
Unit base weight
Economize
Curb
Total weight
Weight used in calculations
665 i lbs.
50 lbs.
115; Ibs.
830 lbs. Width =
830. Ibs., to include duct work, etc.
Seismic:
Fp = (0.4*ap*SDs*Wp)*(1+2*(z/h))/(Rp/Ip)
Fp = 398.815 lbs. <== Controls
Fp(max) = 1.6*SDS*Ip*Wp
Fp(max) = 1276.208 lbs.
Fp(min) = 0.3*SDs*Ip*Wp
Fp(min) = 239.289 Ibs
Fp = 279.17 Ibs. (ASD) 4--
Wp=
SDS=
a =
Rp =
Ip =
z=h=>z/h=
Wind: (Section 29-5.1 of ASCE 7-10)
Fh = qh*(GCf)*Af (Horizontal Force) Fv = qh*(GCr)*Ar (Vertical Uplift Force)
qh = 0.00256*KZ*KZt*Kd*V` =
Fh = 35.02 *Af PSF
Fv = 27.65 *Ar PSF
Fh =
Fh =
F„ =
MOT =
MOT =
MOT =
18.43 PSF
518.27 Ibs.(Transverse Horizontal Force) ASD
329.17 Ibs.(Longltudinal Horizontal Force) ASD
400.64 Ibs.(Vertical Uplift Force) ASD
10236.25 in.-lbs. (Seismic)
12438.52 in.-Ibs. (Wind - Transverse)
7900.14 in.-Ibs. (Wind - Longitudinal)
Load combinations:
Case 10.60 Dead + 0.6 Wind
Case II 0.60 Dead + 0.7 Seismic
Transverse Seismic Hold Down Force =
Longitudinal Seismic Hold Down Force =
27.66 Ibs UPLIFT
-96.22 Ibs
Unit Dimensions
Height = 34: in.
Length = 74: in.
47! in.
830 lbs.
0.961
2.5
6.0
1.01
1.00
Curb Dimensions
Height = 14 in.
Length = 67in.
Width = 371 in.
Basic Wind Speed 110 iMPH
Exposure t B
Average roof height 28.00 ft.
Kz = 0.700 Table 30.3-1
Kd = ` 0.85Table 26.6-1
Kxt = 1.0 Section 26.8.2
(GCr) = Horizontal Gust Factor =
(GCr) = Vert Uplift Gust Factor =
Ar = Vert Proj Area (Transvese) =
A = Vert Proj Area (Longitudinal) =
Ar = Horizontal Projected Area =
Hold down NOT req'd
Transverse Wind Hold Down Force = 287.50 Ibs UPLIFT
Longitudinal Wind Hold Down Force = 69.23 Ibs UPLIFT
File:HVAC wind seismic.xls, modified 2-21-14
1.9
1.5
24.67 ft`
15.67 ft`
24.15 ft
M
cuto8
Design Maps Summary Report
http://ehp3-earthquake.wr.usgs.gov/designmaps/us/summary.php?temp...
MUM Design Maps Summary Report
User -Specified Input
Building Code Reference Document 2012 International Building Code
(which utilizes USGS hazard data available in 2008)
Site Coordinates 47.45°N, 122.25°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category I/II/III
mapquest
USGS-Provided Output
Ss = 1.442 g
S1 = 0.536 g
SMs = 1.442 g
SM1 = 0.805 g
Sos = 0.961 g
Sol = 0.536 g
For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions In the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
1.45
1.50
1.35
1.20
1.05
0.9
0.75
0.60
0.45
0.30
0.15
0.00
0.00
MCER Response Spectrum
0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80
Period, T (sec)
2.00
1.10
1.00
0.90
0.80
0.70
S 0.60
a 0.50
0.40
0.30
0.20
0.10
0.00
Design Response Spectrum
0.00
0.20 0.40
0.60 0.80 1.00 1.20 1.40
Period T (sec)
1.60
1.80
2.00
Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or Implied, as to the accuracy of
the data contained therein. This tool Is not a substitute for technical subject -matter knowledge.
1 of 1 7/31/2015 9:08 AM
SHUTLER
_ CONSULTING
ENGINEERS, INC.
12503 Bel -Red Rd, Sulte 100
Bellevue, WA 98005
(425)450-4075 FAX: (425)450-4076
J08 Lix'LtJ/LIF4Ar4O ✓u po 1.
SHEET NO 3
CALCULATED BY HAI)
OF
DATE [J "3 -6
SCALE lam/ (.1C CI C)
i
{
1
-
-
C
—..
+) 43/4111$
...._._
i'
el
_
__.-...._..-.J.._......
__.._.........
_
. _
1
r
I
i
_ _
__....
_
�
— ....._-3
I�
1
I
,
f
1
•i
I
1
•
[
1
I
J
. -
.421
-71
. ..
-
i .._.......
_�.y�.��j
i
-I�
i
j.
,P
... _—
_ _,._.._._._.
..0
sie
......
--
—. __.
....I.__
—
_._...
_
_...__...__
C
4e
—
--
--
___......__...__
I
-
--
____�
T
--
_...
m....._......._.._.._..._...__...--'--_._..._
— —
__
_
_...._.__._-_.-----._....._____.........-------....___.
--T
--
--
—__
............
...............
........_
.....__
_.._
__...J.__._..._._._
.-_---_
•
_------_
._..._..._._...._.
1
,
LE:
7
!
•
i
Q?.
t,----•
r
i
-,--,
i
idest it
'
—
—
I
_
—
ti
_.Ni-c
F."I
--
SHUTLER
CONSULTING
ENGINEERS, INC.
12503 Bel -Red Rd, Suite 100
Bellevue, WA 98005
(425)450-4075 FAX: (425)450-4076
i
�If l!= �21....�Ib
JDB I et7C11 / UPI A 4O 1VAC 5u4 Per
SHEET NO 4
CALCULATED BY Ml•-•1
DATE 8 t5
SCALE N��
rti. (uLp
' - l . CurLC>
T � A103 � pi
t---
J
I3 - 2. 3 * 3 1_W -�k ur,
1
.5�
bL
OF
N 1274 - U--OtA.T T Z
; i
.. 1.._..- 1�'I----
5t5 t l' �IFD •
;•
}S
1
.. L- I.
1 ;
•
f
SHUTLER
CONSULTING
ENGINEERS, INC.
12503 Bel -Red Rd, SLAW 100
Bellevue, WA 98005
(425)450-4075 FAX: (425)450-4076
jos N01.0616/ LtriAlAD N/CC- .t.?t2e)et
SHEET NO 5 OF
CALCULATED BY
DATE S —3 —LS
SCALE
1
i
1
I
1
i , .
--1
I i I —1— 1
!
r•
i
I I 7!
[
1
'
IL
1
•
I I1i
--T---
Alto
/able Screw Connection
Capacity
(Ibs)
'
_
____.
• •
.-G7,...:.•.1
- ,: ..• con-ua..- .• .. I
.- .. -,5F•filmzi
--_L
.,- • ..
, f.',01L-7, - '
.• • . .tm.-217,77 •
' ---
---1 --
-
in ii,,,D;...,,i,.%.,11:3,,,r,
Iii*q.
.1-0-fritili.
1 ,r,,;..Wrcc. i'laprL3
(#'7,41:i1L.L....it.gral_llh
011aSykir4;-1,0,1j.
,-11•:17.,1:7,51p
—
..---
----
' 1'''11r1)
F4.1•'•11'.'
7-4C-irq114(4. 1_164'
-;-14-14alkill
;
;;EAC
-2--.6.1.,,-14a-i-,-c-
-
- --
-,:-.-
; - - .. - '....
- ..• ,.,,.:
I , 4.00
top?*
FAg,p!
,,igh-iiir,d
ot4v51
00:•!ii...it
:1-_...,.4f:
R4f. igi?ii-
'...644 pit
1
-
---
'
—
2.-2r118
30
0.0168
Rig.1Z-faL741:53f7
' 0.03 2
33 93
13 93
44
1!-A2!64
85
24
!f;17In;,‘1
40
84
1!;TI27;f:-
140
8
ti2()1.g
• 103
29
Z41.1*..1
48-
84
7Ift-tli
40
52 33
!-1.1)WiCi tfE3;i7i
. 105
4.,WA§Ji
175
iiiii
::t.
65
.4"
1
35 ,.fil105 60 .127 -
:'f" .,f21-$9:45 '.••f:;tf0.V.!
63 176 127 ?all:7,
211
- - I
r I
1.4:;•4111349513_131332:ittittl
''''n•ea0.071933
1`:-'6'045507-1'"s1,7'4•4.1$:'
'''nrtial1.1
'fit.4:19
n''214 ''n
'.i,'Il%S'‘q'
.:Mtio
'•11,14F'':
11 'zifir'
!.:L1444 ...i
;.:-t4:0
1M-;14?f.
tedf.G
i::14111,z,
;'11$TA
;•.••.17437_,N :_,-,ilt19:x7.-FMA
''IN': j.t,'45r.F:
,•*:184).74t
Z1:8)I;
$4l';.7;f'
kief1254,-,5 tlri'0 !.23:52f'i 410 lirel '...'
,'.glsift=', P.4i.if! i'lf,14', 2f:, On ,402r;:li
- • 1
i
1 _._..
...... _..
..'4
el:-S.,i'0710171-4"if_ii:r1.4:57.%4
118
n • • 45 -'
39 45
:,<,'EtitiN
214
125
L.140-:•"11
140
n'' • 140 n
'.;'Atr:j.
140
426
.i..-.42fi.ii
426
149-195
90.6k.
195
'
WO)
195
n 523 173.
2.,00:,!i 1:1:.g)-R
648 301
n • 388
,a08::
988
'-557
;e777'fir;
777
'' • :-1913:- .545 660 227 nn. 156 -
;igeo:i:_f f',ItC6! '',1,0.1.47 '',32iffLi ii.Pfli
942 775 16 396 ;
- -1----1"
!
- -
I
I
•
61'""I'-221."'-'11'''712."
,': 97
113
.. .0.1242
.. ;.::-.0017;!••
0.1242
.
r:;-; 50 ;. :!'.85 J.':
50 65
6111'"
•::'214 '.•
214
"It'
',".140
140
.
'''11:*"
;:i %:,140
14
'":1:'''
r..-'425 E
428
'"1-7ik'''
:',105.',
1
.1:555c
':105..
195
-114,- '711::;"
048 ;. ;. 358 ..
548
,
'"'13E8.r
-;,•388 ,,.
388
:nv'
:W.:-
. . ,1 . ;1067
'..,tir,..'' .,.'1,g,, ,,1136i'' .'"IF ' ' 21
!!."405 4 -:. 775 ;.. 1816 ., 468 . ::'1,857.,/
494 775 1016 572 1067 • .-
I
----
- " - '
--1-
-
L.
I
'---
1
i!
1
!
i
, ,
1
I
,
t
1
--i--
I
1
i
,
1
SIMpSOD
1
Strong-Tiee
1
1
Strong-Drive°SDS
1
f
HEAVY-DUTY
1
CONNECTOR
1
Screw
,
i
and Water
1
I
-Head Screw
,
__, ,
, f 1
— !
-3 i
,
I
1.
ii
l•
_
...,,...::• :,
,.:,•,...• ....,,:
•ii. '..•••,:• •
--;-,.. .•••.•.;
•••:,:::::-.f.•,::::::::::::::::AjFicp•mawahhitaidai.:::,•::::::::::::;•,:•,,
• .-. •:•,.::: ;"•.,:gptiloAddwahiquadas,...-
•
....;:- y!; ...:.
.!.:-
-
._. _ _
-- ! •
....
- "
'
3178 •
. Mattel-
Thread
Fasteners
.-:,:••.:::::••::::•.,:::::lheirkteep::::;•:;::::::-.:i::::::::.
ivithdraWay
- ..-• • .- ;,.....•.•stwar(ion)
,. ,. • ,...;: •...
withdraw?
.ii-de,
• L.
1
.01.16;•:•.i.•!,i
!?9,19,Illi,
•',11.!1,1•
Wocceice 1100
..;:8 01.010110e;,(,::..:•,::..P99.:;i:x:
woo;
ONO
h1,4;13C8Iejdo.100....;;;1(199).:ii:i:ii
. ,
. . .1 .. ... . .
);-"IIIIIIY;
1'a
-iiI:tglit:'7,-A
e44.
•,40,,P,:.5.:.,n,
StY4OII•1
••••
t;Oobei&'
1-e0.0iiii•
W,IiliidfddilsifffSiltDrell.
P:..1a..i.4ti:
a#Ca1,Ve
lV,
l0o4t-aiifjkq
wifitomio
40100•Kiitim
tali
Mi,
• ,•
sc: x ut
S083(1.251
-
-
-
-
60
60
60
-
-
. -
45
45
45
-
170
: !
16x114
SDS25112
1
1500
-
-
250
250
250
170
-
-
180
180
180
120
ID
•1/4Yi'2'4
SDS25208
iilive
iz)1806N
'f•,.4":,
'::.',.:-7,i
25-6
•,t-g.V:
::::.200'i
'...;.-.::-21.5j.
i':':
'444
5100
ii210tA'
.,E;I:10-4:
{K-T115tiLFR,
_
NI
Y. g%
99925212
1;114 :-.;
91100 1,;
,1611..-
:;;;;4:;;;
:250.
:390:.
1:;*429.:
5::;.:
ii135f,
.:1....;.::.;
law
:::280.,.
Joo;',
!..1180.:6;-::.
----1--------
i...- --
1.
15)(3
SDS25300
2
950
280
-
250
420
420
345
200
-
180
300
900
240
15,
1 1
__
.. . Il
1/4 x 31/4
SDS25312
21/4
900
340
940
250
420
420
985
245
245
180
300
300
270
L1,
4,._
', 1.1
05x454
S0S25412.
:25.i.„
•:;-.5904:.,
;.:350
340 ...
:258
:420..
-:: ... -:.
:::::,1175.:..... :
;150
,,,•245,,
180..
....$00 ,,
-308.,
,:.1..,•330.r,-
F20
; i
le
'..:suig,I.
s0525500
..2y.i,i
:.4,509:;,;i
....:150 .::
_NO ,.
.24.0
:::420::
...420 •i•
:.•:•••1:47$,. •::
:250i
)7245.::
180.,
:.300 .i
.;.,300.
'. :1330 ,!:,;•:.
[
.
Nilti.
S0S2500
,It'A
4:§(19:34
:::350i
a340:fi!
2O,,:1420:
:;:,420;:i
'i-fi::V560;..,:i*
,12601-.1
42402
...i1801
.`300.1
asolin
4,4.g995dIAFil
1111
14x8
50825800
31/4
400
•f•.450-?
P400.4
-'Ipq,
il,.420)
•i!420:•,
?S..860.:r.
1,:jM9:2
.144.0.3,7
41h4i
Ofiti...it
if3010..g
1!-M39.5..1.47.4
1
1
-
:
-1
.
r
..___
T
1-
_i_.
,
1-
I
--I-
i.
i
i
i
.....
I
1
I
i
1
. 1
1
I
1
i
4
;
.
i
_I_
I
i
I
i
I
-1
---`
i
I
-4--
i
4
I 1
1
1
T
I
1
I
I
I
.----r-
1
----+-
i
!
1
,
Jr---
_L.
i--
r
i
. I
•-i
1
T-
i
1 .
+
I
-
1
I
--1-
i
I
i
I
I
I
i•
I
I
l
r
i
I
_111111 SHUTLER
�- CONSULTING
ENGINEERS, INC
12503 Bel -Red Rd., Suite 100
Bellevue, WA 98005
(425) 450-4075
FAX (425) 450-4076
JOB ?OW/
LIt% YD tt\��.�I parr
SHEET NO. OF tl
CALCULATED BY
DATE 6 -3-6
SCALE
C3
t.
A
SHUTLER
CONSULTING
ENGINEERS, INC
12503 Bel -Red Rd., Suite 100
Bellevue, WA 98005
(425) 450-4075
FAX (425) 450-4076
?40 (4 4 .fit ,e
r �
)ct) Pr d k t$D.9 r ONL
• Did ►'� 3b.(06'4I Gt G
5
-15 (I /2 3cs - 31'26 • t< list
Tlf
fL4r 1.
rn
rut
jojiblIANbi U?1 t t-W4C SLuepoeT
SHEET NO. 01.1
1 ,, I
CALCULATED 8Y MI.1
OF
DATE 6-3-6
SCALE 1.1-1-5
(Mc-
tev
.b+
G
sp*
S 1 o1,tW 4A-1- ' Lws2lo .0 n =10�
w (.1. = 1-50F Lea
2bb(�`�=
b{ lobo( 4= lQ
V eel -5
I 40 LtzV3o p
L• l5kZ//3bb���`�i�,�
4x
IIt V62- o
6
1*Z
3.c4*'rr
sd
Vrr
et. oil-
e llZb psi
ok
6
REF-1 and 2
NuTone
Architectural & Engineering Specifications
December 2007
DESCRIPTION
BLOWER:
• Plug-in, permanently lubricated motor - engineered for
continuous operation
• Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
• Low RPM for quiet operation
• Resilient anti -vibration motor mounts
HOUSING:
• Rugged, 26 gauge, galvanized steel construction
• Polymeric, 4" round duct connector with tapered sleeve and no
metallic clatter
• 7-5/8" height allows for 2" x 8" (nominal) joist installations
• Sturdy, easy, four -point mounting directly to joist
• Includes unique spacer (patent pending) for mounting to
engineered "I" joists
• Can be mounted in ceilings up to 12/12 pitch
GRILLE:
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
BUILDER PACKS:
• Model QTRNO5OF includes blower and grille only (packed 1
per carton)
• Rough -in housing required - order NuTone Model
QTXRN000HF (4 housings per carton)
- Includes hanger bars to position housing anywhere
between 16" to 24"-on-center joists (4 sets of hangers per
carton)
- Two sets of mounting holes for hanger bars allow flush
installation with bottom or top of drywall
CONTROLS (Purchase separately):
• Refer to NuTone's catalog for a complete line of accessories
to effectively adapt these fans to your construction
requirements.
U.L. Listed for use over bathtubs and showers when connected
to a GFCI protected branch circuit (ceiling mount only).
3-Year Warranty
INSTALLATION
2100
HVCERTI
ILE QTRN Series
Fans
MODELS QTRN050F, QTRN080, QTRN110
ARCHITECT'S SPECIFICATION
• Ceiling Ventilator shall be NuTone Model QTRNO5OF (QTRN080)
(QTRN110).
• Ceiling Ventilator shall have corrosion resistant galvanized steel
housing with four -point mounting capability. It shall be ducted to
a roof or wall cap using 4" round ductwork.
• Blower assembly shall be removable, have a centrifugal -type
blower wheel and a permanently lubricated motor designed for
continuous operation and mounted with resilient anti -vibration
mounts.
• Non-metallic damper/duct connector shall be included.
REVr o g h
CODE C@MPIA* 1
APPROVIZOthator s all be U.L. List o e 96trrliathtubs and
showers when con ected to a Ittt:Jd'6r&ch circuit.
CITY OF TUKWILA
Complete installation instructions are included with each n.
Broan-NuTone LLC Hartfor
AUG 14 2015
no less than 50 (80) (110) CFM and sound
n 0.4 (1.0) (1.5) Sones. All air and sound
fied by HVI.
AUG 0 4 2015
,E4116.0INGANIMON 888-336-PERMIT CENTER
City of Tukwila
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
¥AV.olDm
99044088A
)
PERFORMANCE RATINGS
QTRN SERIES FANS
HVI PERFORMANCE
Model
Sones
@0.1"Ps
CFM
@0.1"Ps
QTRNO5OF
0.4
50
QTRN080
1.0
80
9TRN110;
1.5
110
2100
HVI
CERTIFIED
AMPS
HVI-2100 CERTIFIED RATINGS comply with
new testing technologies and procedures
prescribed by the Home Ventilating Institute, for
off -the -shelf products, as they are available to
consumers. Product performance is rated at0.1
in. static pressure, based on tests conducted in
AMCA's state-of-the-art test laboratory. Sones
are a measure of humanly -perceived loudness,
based on laboratory measurements.
Model
Amps
QTRNO5OF
0.3
QTRN080
0.7
(QTRN110;
0.9
WEIGHT
Model
Shipping
Weight
QTRNO5OF
5.9 Ibs.
QTRN080
10.6 lbs.
;QTRN110
10.6 Ibs.
NuTone
AIR FLOW PERFORMANCE
0.6
0.5
di 0.4
• 0.3
a 0.2
0.1
0.0
0.9
0.8
0.7
oi 0.6
0.5
O 4
0.3
0.2
0.1
0.0
0
MODEL QTRNO5OF
10
20
30 40
Airflow (cfm)
MODEL QTRN080
50
60
70
0.9
0.8
0.7
0.6
0.5
C 0.4
a 0.3
0.2
0.1
0.0
0
10 20 30 40 50 60
Airflow (cfm)
'MODEL QTRN110
70
80
90 100
10
20
30
40
50
60 70
Airflow (cfm)
80 90 100 110 120
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
Co United Technologies
SUBMITTAL
Project
-Untitled 10
Date
Monday, July 27, 2015
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 1 4 2015
City of Tukwila
BUILDING DIVISION
FILE
RECEIVED
CITY OF TUKWILA
AUG 0 4 2015
PERMIT CENTER
WA19.0101
Table Of Contents
Project: -Untitledl0
Prepared By:
07/27/2015
04:04PM
3tongaspk 3
Unit Report 4
Certified Drawing 5
Performance Summary 9
Unit Feature Sheet 12
Spec Sheet 13
(-E1
1 t L
Packaged Rooftop Builder 1.39r Page 2 of 13
3 ton gas pk
Project:-Untitledl0
Prepared By:
07/27/2015
04:04PM
3 ton gas pk
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Unit Feature Sheet
Spec Sheet
Packaged Rooftop Builder 1.39r Page 3 of 13
Unit Report For 3 ton gas pk
Project:—Untitledl0
Prepared By:
07/27/2015
04:04PM
Unit Parameters
Unit Model. 48KCDA04A2A5-0A0A0
Unit Size. 04 (3 Tons)
Volts -Phase -Hertz. 208-3-60
Heating Type. Gas
Duct Cfg• Vertical Supply / Vertical Return
Low Heat
Single Stage Compressor Models
Lines and Filters
Return Air Filter Type. Throwaway
Return Air Filter Quantity. 2
Return Air Filter Size• 16 x 25 x 2
Unit Configuration
Medium Static Option Belt Drive
AI/Cu - AI/Cu
Base Electromechanical Controls
Standard Packaging
Warranty Information
1-Year parts(std.)
5-Year compressor parts(std.)
10-Year heat exchanger - Aluminized(std.)
No optional warranties were selected.
Dimensions (ft. in.) & Weight (Ib.) ""'
Unit Length. 6' 2.375"
Unit Width. 3' 10.75"
Unit Height. 2' 9.375"
**• Total Operating Weight. 665 Ib
"' Weights and Dimensions are approximate. Weight does
not include unit packaging. Approximate dimensions are
provided primarily for shipping purposes. For exact
dimensions and weights, refer to appropriate product
data catalog.
NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods.
Ordering Information
Part Number
Description
Quantity
48KCDA04A2A5-0A0A0
Rooftop Unit
1
Base Unit
Medium Static Option Belt Drive
None
Accessories
CRECOMZR020A02
Standard Leak Vertical EconoMi$er IV with solid-state controller
1
CRRFCURB001A01
14-inch Tall Roof Curb
1
Packaged Rooftop Builder 1.39r
Page 4 of 13
Certified Drawing for 3 ton gas pk
FIELD POWER SUPPLT ROLE
ER SUPPLY KNOCKOUT
GAUGE ACCESS PLUG
3/4'-14 NPT CONDENSATE DRAI
1/2'-14 NPT GAS CONNECTION
2 1/2 ' I641 DIA POWER SUPPLY KNOCK -OUT
gitE
RAI
coW
0
712
s
0
sW
111111111111111111111111111111111
IIIIIIIIIIIIII IIII
111111111111111111111111
111111111111111111
MIIII' 1111111111111111
11111 !IIIIIIIIIIIIIII
o
0
1
II IIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIII IIIIII IIII IIII
o
cc
La-
48KC000281
acC
LC
W�
W�
Packaged Rooftop Builder 1.39r
Certified Drawing for 3 ton gas pk
0
1-2
CC
0
V
V
CC
O
V
0
a
•:oo I' •i 'fi': : oo
111111111111111111111111111111111
111111111111111111
111111111111111111111111
111111111111111111111111
111111111111111111111111111111111
1111111111111111111111111
48KC000281
v
CC
0r
w
Page 6 of 13
Packaged Rooftop Builder 1.39r
Certified Drawing for 3 ton gas pk
oa
N 0
••
0
0
G)
c >,
D m
v
G)
U G)
G) a.
O G)
as
A
Service Clearance
11111
4IP...1X
i,.
I
4.,
,.
,,,,,,
038337
z
0
• Unit disconnect is mounted on panel
• No disconnect, convenience outlet option
• Recommended service clearance
• Minimum clearance
•Surface behind serviceris grounded (e.g., metal, masonrywall)
•Surface behind servlceris electrically non-conductive (e.g., wood, fiberglass)
•Check for sources afflue products within 10- ft. of unit fresh air intake hood
• Side condensate drain is used
• Minimum clearance
• No flue discharge accessoryinstalled, surface Is combustible material
• Surface behind servicer is grounded (e.g., metal, masonry wall, another unit)
• Surface behind servlcer is electrically non-conducthre (e.g., woodfiberglass)
• Check for adjacent units or building fresh air Intakes within 10- ft. of this unit's
flue outlet
NO7E: Unit not designed to have overhead obstruction. Contact Application Engineering for guidance on any
application planning overhead obstruction or vertical dearances.
F
0
u
V
E
E-
48-In (1219 mm)
42-In (1067 rim)
g
E�E�E
E
l'
N a
P.,2
it'
a"
A
0
e c
c e
e
..
e
z
0
Q
Q
m
u
0
Packaged Rooftop Builder 1.39r
Certified Drawing for 3 ton gas pk
11
R$
W
LLI
kr
a
1
N4,
i
I
i
$15
a
I
i
Packaged Rooftop Builder 1.39r
Performance Summary For 3 ton gas pk
Project:—Untitledl0
Prepared By:
07/27/2015
04:04PM
Part Number:48KCDA04A2A5-0A0A0
ARI SEER• 14.00
Base Unit Dimensions
Unit Length. 74.4 in
Unit Width. 46.8 in
Unit Height. 33.4 in
Operating Weight
Base Unit Weight 490 Ib
Medium Static Option Belt Drive- 10 Ib
Accessories
Standard Leak Vertical EconoMi$er IV with solid-state controller 50 Ib
14-inch Tall Roof Curb• 115 Ib
Total Operating Weight- 665 Ib
Unit
Unit Voltage -Phase -Hertz 208-3-60
Air Discharge. Vertical
Fan Drive Type• Belt
Actual Airflow- 1200 CFM
Site Altitude. 449 ft
Cooling Performance
Condenser Entering Air DB• 85.0 F
Evaporator Entering Air DB• 79.2 F
Evaporator Entering Air WB• 64.4 F
Entering Air Enthalpy• 29.63 BTU/Ib
Evaporator Leaving Air DB• 56.2 F
Evaporator Leaving Air WB• 54.1 F
Evaporator Leaving Air Enthalpy. 22.75 BTU/Ib
Gross Cooling Capacity. 36.60 MBH
Gross Sensible Capacity. 29.26 MBH
Compressor Power Input 2.59 kW
Coil Bypass Factor 0.119
Mixed Air
Outdoor Air Airflow. 420 CFM
Outdoor Air DB• 85.0 F
Outdoor Air WB• 65.0 F
Outdoor Air Htg. Temp • 23.0 F
Return Air DB• 76.0 F
Return Air WB• 64.0 F
Return Air Htg. Temp • 70.0 F
Heating Performance
Heating Airflow: 1200 CFM
Entering Air Temp• 53.6 F
Leaving Air Temp• 97.5 F
Gas Heating Input Capacity 72.0 MBH
Gas Heating Output Capacity. 0.0 / 56.0 MBH
Temperature Rise- 43.9 F
Supply Fan
External Static Pressure. 0.50 in wg
Options / Accessories Static Pressure
EconoMi$erlV / EconoMi$er2• 0.04 in wg
Total Application Static (ESP + Unit Opts/Acc.)• 0.54 in wg
Fan RPM• 850
Packaged Rooftop Builder 1.39r Page 9 of 13
Performance Summary For 3 ton gas pk
Project:-Untitledl0
Prepared By:
07/27/2015
04:04PM
Fan Power 0.44 BHP
NOTE Selected IFM RPM Range: 770 -1175
Electrical Data
Voltage Range- 187 - 253
Compressor #1 RLA• 10.4
Compressor #1 LRA• 73
Outdoor Fan Motor Qty 1
Outdoor Fan FLA (ea)• 1
Indoor Fan Motor Type• MED
Indoor Fan Motor FLA• 5.2
Combustion Fan Motor FLA (ea)• 0.48
Power Supply MCA• 20
Power Supply MOCP (Fuse or HACR)• 25
Disconnect Size FLA- 19
Disconnect Size LRA• 111
Electrical Convenience Outlet None
Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage
Acoustics
Sound Power Levels, db re 10E-12 Watts
Discharge Inlet Outdoor
63 Hz 83.6 85.5 78.2
125 Hz 76.3 73.6 78.0
250 Hz 66.0 59.1 74.2
500 Hz 62.6 58.8 73.3
1000 Hz 59.3 58.5 70.6
2000 Hz 53.7 52.5 66.0
4000 Hz 54.8 47.3 62.4
8000 Hz 49.0 38.9 56.9
A -Weighted 66.7 64.6 76.0
Advanced Acoustics
Advanced Accoustics Parameters
1. Unit height above ground. 30.0 ft
2. Horizontal distance from unit to receiver 50.0 ft
3. Receiver height above ground• 5.7 ft
4. Height of obstruction. 0.0 ft
5. Horizontal distance from obstruction to receiver 0.0 ft
6. Horizontal distance from unit to obstruction. 0.0 ft
Detailed Acoustics Information
Packaged Rooftop Builder 1.39r Page 10 of 13
Performance Summary For 3 ton gas pk
Project:-Untitledl0
Prepared By:
07/27/2015
04:04PM
Octave Band Center Freq. Hz
63
125
250
500
1k
2k
4k
8k
Overall
A
78.2
78.0
74.2
73.3
70.6
66.0
62.4
56.9
82.9 Lw
B
52.0
61.9
65.6
70.1
70.6
67.2
63.4
55.8
75.4 LwA
C
45.8
45.6
41.8
40.9
38.2
33.6
30.0
24.5
50.5 Lp
D
19.6
29.5
33.2
37.7
38.2
34.8
31.0
23.4
43.0 LpA
Legend
A Sound Power Levels at Units Acoustic Center, Lw
B A -Weighted Sound Power Levels at Units Acoustic Center, LwA
C Sound Pressure Levels at Specific Distance from Unit, Lp
D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA
Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI
Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed
that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical
estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be
appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate
an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an
Acoustical Engineer or a person with sound prediction expertise should be consulted.
23
18
16
04
02
CO
00 03 06 Q3 12 15
AiAbw(CFM-thousands)
RPM=850 BHP=0.44 MaxunumRPM=1175 MaximumBHP=2.90
Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion.
SC- System Curve RP-RatedPoint
18
FanCurve
100RPAA
\ `
, \
13ooRPM \
\
15XRPM
\
\
3.o0BHP
_
900RPM
`
\
-
i
`\\
- 700RPM
AillL\
\
-
.14111iiiii._o.7�BHP
\
-I BHP\
1.00BHP
\
,o SoaHP
21
24
Packaged Rooftop Builder 1.39r Page 11 of 13
Unit Feature Sheet for 3 ton gas pk
Project:-Untitledl0
Prepared By:
07/27/2015
04:04PM
ASNRAE{
COMPLIANT
Carrier
WeatherMaker' — 48KC
PACKAGED ROOFTOP GAS HEATINGIELECTRIC COOLING UNITS -14 SEER
0
Puron.
3, 4, 5 TONS
WEATHERMAKER SERIES
WeatherMaker 48KC (14-SEER) units are one-piece gas
heating, electric cooling units that are pre -wired and charged
with Puron (R-410) refrigerant. They are factory tested in both
heating and cooling modes, and rated in accordancewith AHRI
Standards 210240. WeatherMaker units are designed in
accordance with UL Standard 1995, and listed by the
Underwriters' Laboratories.
Approved and certified by:
A• CERTIFIED-
US
Certified to ISO 8001
STANDARD FEATURES INCLUDE:
• !Puron (R-410A) HFC refrigerant
• Meets and exceeds ASHRAE 90.1 energy efficiency levet
• Scroll compressors with internal fine break and overload protection
• Single -stage cooing capacity control
• SEER'supto14.0.EER'supto12.0
• Acutrol" refrigerant metering system
• Exclusive non-conosne composite condensate pen in socordance with
AS.HRAE Standard 62. sloping desgn, side oreenterdrain
• Standard cooing operation up to 1157(46`C)and down to 40°F (4°C)
- down to 25' F (-4• C) with winter start kiL
• 'Pre -panted exteriorpanetsend primer-coeted nteriorpanettested to
500 hours salt spray protection
• Fully insulated cabinet
• Exclusive IGC sold -state control for on -board diagnostic' will LED
error code designation bumercontrollogic end energy saving indoor
fan motor delay
• Low tiOx models that meet Ceifomie Air Quaky Management
• Induced draft gas heat combustion desgn
• Redundant gesvalves withuptotwvostagesofheating
• Low pressure end high pressure sitcti protected.
MAINTENANCE FEATURES:
• Access panels with easy grip handles
• Innovative easystarting, no -strip screws on unitsocesspanels
• Two-inch disposable return skaters and Tool4ess fitter amass door
• Direct Drive -ECM ndoormotor. standard with optional bek drive
systems
• Terminal board facilitating sample safety circuit troubleshooting and
simplified control box arrangement
• Exclusive IGC soid-state control for on -board diagnosticswab LED
error code designation, burner control logic and energy saving indoor
fan motor delay.
INSTALLATION FEATURES:
• Thnu-the-bottom power entry cepabity
• Single point gas and el ectricconnections
• Full perimeter base ref withbuit-n rigging adapters and fork slots
• Field convenble from vertical to horizontal airflow
STANDARD WARRANTY:
• 10-yearheatexchanger— 15-yearstaintesssteel option
• 5-year compressor
• 1-yearpads
• Many optional upgrades also available
OPTIONS INCLUDE BUT ARE NOT LIMITED TO:
• Premaert.nk and RTU Open Multi Protocol DDC Controls
• Supply and Return Air Smoke' Detectors. high static motors
• Louvered condensercoiguards
• Disconnect switch and convenience outlet options
• Stainless Steel heat exchanger option
• Corrosion resistant col coating.
• ligh steticmotor options
• Patented Humidi- iZee adaptive dehunidtfication system. This option
also ncludesMotormester I controls
• hinged access panels
• Integrated econonezersystern. Standard and Ultra Low Leak versions
For a complete fist of options and accessories referto the Product Data
Catalog for this unit.
Packaged Rooftop Builder 1.39r Page 12 of 13
Spec Sheet for 3 ton gas pk
Project:-Untitledl0
Prepared By:
07/27/2015
04:04PM
Packaged Rooftop Builder 1.39r Page 13 of 13
1/1,ERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M15-0101 DATE: 08/05/15
PROJECT NAME: PROLOGIS - UPLAND TI
SITE ADDRESS: 1139 ANDOVER PARK W
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division '"
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 08/06/15
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 09/06/15
Approved
Corrections Required
Approved with Conditions ❑
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
UNIVERSAL REFRIGERATION III
Page 1 of 2
Horne Irricio en Espanol Contact.
Search L&I
A-Z Index Help My Secure I: &I
Safety Claims & Insurance Workplace Rights Trades & Licensing
0 Washington State Department of
Labor & Industries
UNIVERSAL REFRIGERATION INC
Owner or tradesperson
Principals
GATES, CHRISTOPHER A, PRESIDENT
GALVIN, BRYAN S, VICE PRESIDENT
VERNON, GUY E
(End: 01/01/1980)
JACKSON, SHELDON G
(End: 01/01/1980)
OSENBAUGH, CHARLES R
(End: 01/01/1980)
RAEDER, STEVEN C, PRESIDENT
(End: 03/29/2012)
Doing business as
UNIVERSAL REFRIGERATION INC
WA UBI No.
600 599 723
PO BOX 614
AUBURN, WA98071-0614
253-939-5501
KING County
Business type
Corporation
Governing persons
BRYAN
GALVIN
CHRIS GATES;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
..................._................................_....................
Meets current requirements.
License specialties
COMMERCIAL/INDUSTRIALIREFRIG
License no.
UNIVERI159RF
Effective — expiration
12/06/1985— 04/01/2016
Bond
.................
AMERICAN STATES INS CO
Bond account no.
EX903622
$6,000.00
Received by L&I Effective date
03/18/2002 12/06/2001
Expiration date
Until Canceled
Insurance
........._..._...........
American Economy Insurance Co $1,000,000.00
Policy no.
01 C179965210
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 8/19/2015