Permit M15-0103 - CENTURYLINK - AIR HANDLER AND EXHAUST FANS
CENTURYLINK 6101 S 180T ST 101 M15-0103 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3523049120 Permit Number: M15-0103 6101 S 180TH ST 101 Project Name: CENTURYLINK Issue Date: 9/4/2015 Permit Expires On: 3/2/2016 Owner: Name: Address: SEGALE PROPERTIES LLC PO BOX 88028 , TUKWILA, WA, 98138 Contact Person: Name: MELODY DERRICK Address: 980 S HARNEY, SEATTLE, WA, 98109 Contractor: Name: Address: License No: Lender: Name: Address: EMERALD AIRE INC 5108 D ST NW , AUBURN, WA, 98001- 2418 EMERAAI055BL Phone: (206) 382-1900 Phone: (253) 872-5665 Expiration Date: 4/1/2017 DESCRIPTION OF WORK: INSTALL (1) 50 TON AIR HANDLER AND (3) EXHAUST FANS ADDITION TO SPACE. ASSOCIATED DUCTING FOR BATTERY ROOM EXPANSION Valuation of Work: $350,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $4,019.22 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Oiti& ti/ film Date: ' 6 15 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: d9z Print Name: 1\-'(0 ( fit Q E Date: b-!' 011-15' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Special inspection for sprayed fire-resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire -resistance design as designated in the approved construction documents. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***MECHANICAL PERMIT CONDITIONS*** 13: Ali mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit/Center (206/431-3670). o y y 4 14: Manufacturers installation instructions shall be available on the job sits at the time of inspection. 15: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 26: Battery room expansion to maintain compliance with International Fire Code section 608 Stationary Storage Battery Systems. 28: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0704 SMOKE CONTROL TEST CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: 4t1S—o[u3 1)--49 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 6/6 / Tenant Name: ,&) sq-. I t 07 E0.er Comte r . PROPERTY OWNER Name: cl .,A..e ]i er e?� Address: , n e ip /` City: t) . I.t64 ' Stater Zip /S CONTACT PERSON — person receiving all project communication Name: 't n I Address �>0 Jae /n , e LL�r /� City: c f j %} State . ZiP92 09 lCs�'#-1 Phon0! 3 �2 '/900 Fax: (� Email // Of. 611D q... derrt rie r'Lt_ e'Cc . CC King Co Assessor's Tax No.: U 23 0 7 9/ 2. 6 Suite Number: Floor: New Tenant: ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: i Q l tell Gii r Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ ,5—e) d Describe the scope of work in detail: , f e r J • r . �� j `/cJ C Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type J Qty Furnace <l 00k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LA ' S OF THE STE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT Signature: Print Name: 1 Mailing Address: Cl ZED AGE T: Date: b (2 70/5- Day Tel phone: 26 -Wv6 7- e City tate Zip H:\Applications\Porms-Applications 0n Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt` City of Tukwila DESCRIPTIONS ACCOUNT - QUANTITY PAID PermitTRAK $65.00 M15-0103 Address: 6101 S 180TH ST 101 Apn: 3523049120 • $65:00 MECHANICAL $65.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R6487 R000.345.830.00.00 1.00 $65.00 $65.00 Date Paid: Friday, October 23, 2015 Paid By: EMERALD AIRE Pay Method: CHECK 2236 Printed: Friday, October 23, 2015 9:38 AM 1 of 1 C4J SYSTEMS rOLA 341Lz 90� Cash Register Receipt City of Tukwila Receipt Number R6091 DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $3,246.29 M15-0103 Address: 61015180TH ST 101 Apn: 3523049120 $3,246.29 MECHANICAL $3,091.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $3,059.20 TECHNOLOGY FEE $154.59 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6091 R000.322.900.04.00 0.00 $154.59 $3,246.29 Date Paid: Friday, September 04, 2015 Paid By: EMERALD AIRE Pay Method: ACCOUNT Printed: Friday, September 04, 2015 10:12 AM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ( ACCOUNT I QUANTITY I PAID $4,626.33 D15-0205 Address: 6101 S 180TH ST 101 Apn: 3523049120 $3,853.40 DEVELOPMENT $3,853.40 PLAN CHECK FEE R000.345.830.00.00 0.00 $3,853.40 M15-0103 Address: 6101 S 180TH ST 101 Apn: 3523049120 $772.93 MECHANICAL $772.93 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R5925 R000.322.102.00.00 0.00 $772.93 $4,626.33 Date Paid: Wednesday, August 12, 2015 Paid By: DOUGLAS DUNDAS Pay Method: CREDIT CARD 04581D Printed: Wednesday, August 12, 2015 12:02 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f �/ C (A k Type o,fa nspection: /vi k F.0 Gt Address: r 6/a /J f o7' St. # #o ( Date Called: Special Instructions: fr� Date Wanted. '6 1 -/ a.m. p.m. Requester: , IAC SkkkCt Phone No: 2906-39O 5-%37 Approved per applicable codes. ElCorrections required prior to approval. fr COMMENTS: Pei !fat��(T P�*3 '-o(n.t Inspector: Date — )� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /L((S- 0(0) Project:t C. r CA- f�.k Type f Inspgction: �b ���, Address./ (0SS. (gOft"f1`1(6( Date Cail@'d: Special Instructions: /1-/11 Date Wanted: /€ .-30-IT a.m. p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: rcw%u f4s//e/d� acrifi,67 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. (,7- o(c3 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188, 06) 431-3670 Permit Inspection Request Line (206) 438-9350 e ProW r �r %� We of I tior Type/fi- Address: ( 6 (0 (Se. (50''-Sil, f I Date Called: Special Instructions: 4,1 Date Wanted: _ /0 — — 0 I a.m. p.m. est r: k(Il_skuey Phone No: 2-06 -3TO-, 32 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Dater 6 — f (S REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Ice INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M (s 0(03 Project: • r Type of Inspection: Address: opCS.(50 fr-eea( Date Calle • Special instructions: /t� Date Wa ted: f'� 2i — V a.m. P.m. ReNtx:frL fi c f.y ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: r?( 144 (0‘.1 • Inspector: (E Dater 9 3 ff REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. M�5-olb3 MECHANICAL SERVICES Project: Architect: Design Engineer: No: Name Address Name Address HARDIN AND SONS, INC. 2120 MERIDIAN AVE E EDGEWOOD, WA 98371 (253) 952-0467 CERTIFIED TEST, ADJUST, AND BALANCE REPORT 4268 Date: 02/03/16 CenturyLink Tukwilla Cyber Center 61001 Soouth 180th Street Tukwilla, WA 98188 KDW Salas O'Brien, LLC 10202 — 5th Avenue NE, Suite 300 Seattle, WA 98125 Phone (206) 547-1940 FAX (206) 547-8212 Name Address KDW Salas O'Brien, LLC 10202 — 5th Avenue NE, Suite 300 Seattle, WA 98125 Phone (206) 547-1940 FAX (206) 547-8212 HVAC Contractor: Name Address NEBB TAB Firm: Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 Emerald Aire 5108 D Street Auburn, WA 98001 RECEIVED CITY OF TUKWILA Phone 253-872-5665 FAX 253-872-5797 Name Address Hardin and Sons, Inc. FEB 8-8 2016 PERMIT CENTER 2120 Meridian Avenue E Edgewood, WA 98371 Phone 253-952-0467 FAX 253-862-6029 TAB Certification Number: 2646 frU/.OIO? 1 of 22 Centu Link TukwiCyber Center.xlsx CenturyLink Y HARDIN&SCANS MECHANICAL SERVICES Project: Architect: Design Engineer: No: Name Address Name Address HARDIN AND SONS, INC. 2120 MERIDIAN AVE E EDGEWOOD, WA 98371 (253) 952-0467 CERTIFIED TEST, ADJUST, AND BALANCE REPORT 4268 Date: 02/03/16 CenturyLink Tukwilla Cyber Center 61001 Soouth 180th Street Tukwilla, WA 98188 KDW Salas O'Brien, LLC 10202 — 5th Avenue NE, Suite 300 Seattle, WA 98125 Phone (206) 547-1940 FAX (206) 547-8212 Name Address KDW Salas O'Brien, LLC 10202 — 5th Avenue NE, Suite 300 Seattle, WA 98125 Phone (206) 547-1940 FAX (206) 547-8212 HVAC Contractor: Name Address NEBB TAB Firm: Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 Emerald Aire 5108 D Street Auburn, WA 98001 Phone 253-872-5665 FAX 253-872-5797 Name Address Hardin and Sons, Inc. 2120 Meridian Avenue E Edgewood, WA 98371 Phone 253-952-0467 FAX 253-862-6029 TAB Certification Number: 2646 1 of 22 CenturyLink Tukwilla Cyber Center.xlsx Project Address STATEMENT OF CERTIFICATION aER' H .F I i4 CenturyLink Tukwilla Cyber Center 61001 Soouth 180th Street Tukwilla, WA 98188 The data presented in this report is an exact record of system performance and was obtained in accordance with NEBB Standard Procedures. Any variances from design quantities which exceed NEBB tolerances are noted throughout this report. The air distribution systems have been tested & balanced and final adjustments have been made in accordance with NEBB "Procedural Standards for Testing, Adjusting, Balancing of Environmental Systems" and the project specifications. NEBB TAB Firm Hardin and Sons, Inc. REG. NO. 2646 Certified by Mike Hardin Date 02/03/16 (Air TAB Supervisor) The hydronic distribution systems have been tested & balanced and final adjustments have been made in accordance with NEBB "Procedural Standards for Testing, Adjusting, Balancing of Environmental Systems" and the project specifications. NEBB TAB Firm Hardin and Sons, Inc. REG. NO. 2646 Certified by Submitted & Certified By: NEBB TAB Firm TAB Supervisor Mike Hardin Date 02/03/16 (Hydronic TAB Supervisor) Hardin and Sons, Inc. Mike Hardin REG. NO. 2646 Signature Certification Expiration Date 03/31/16 Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 2 of 22 CenturyLink Tukwilla Cyber Center.xlsx BALANCING PROCEDURES Generic Balancing Procedures: AIR HANDLING UNITS / EXHAUST FANS / SUPPLY FANS Each air handling unit is assigned a unique name and identified on a schematic flow diagram for cross reference with log sheets. At the time of balance the following procedure is followed: 1. Check all branch, main line, and terminal dampers to insure they are in the full open position. 2. Verify that all controls are programmed, operate, and are in the correct positions. 3. For units requiring filters, check to see if the filters are in place and clean. Block filters to simulate dirty condition. 4. Record all fan and motor nameplate data. 5. Check for proper fan rotation. 6. Test and record fan rpm with a tachometer. 7. Test and record motor running amps and volts with a clamp -on volt/amp meter. 8. Test and record static pressure for suction and discharge using a magnehelic gauge or a U-tube manometer. For units with filters, test and record the static pressure drop across the filters. 9. Make a pitot traverse of main ducts, and record the unit's cfm. This is accomplished with a pitot tube and manometer gauge or a U-tube manometer. The number of points and positions depend on the size and configuration of the duct; NEBB procedures will be followed. A duct cannot be traversed because of inaccuracy if it has a velocity of less than 1000 fpm or if traverse points cannot be located at least 7.5 diameters from a turbulence causing device. The quantity of air in such a duct is determined from the unit's total terminal cfm or rotating vane anemometer readings. 10. After initial terminal readings have been made, adjust the unit to within 10% of design cfm. 11. For supply fans only, set outside and return air appropriately. 12. Repeat steps 6 through 9 after all terminals are balanced and set to within +/- 10% of design. 13. A minimum of one outlet per system will be full open from fan to outlet and will be designated as the wide open path in the balance report. 14. Prepare log sheets of readings for final report to illustrate the conditions of flow in the unit before and after balancing. 15. Record all associated controls settings in the remarks section of each Air Handling Unit Test Sheet or in the T.A.B. Summary. Examples of these settings would be Duct Static Setpoint for VAV systems, Minimum Outside Air Control Damper settings for fresh air requirements, etc. 16. Make-up Air Units and other similar fans will be tested as described above. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 3 of 22 CenturyLink Tukwilla Cyber Center.xlsx BALANCING PROCEDURES TERMINALS Each terminal is assigned a number that is unique to its air handling unit or box and is identified on a schematic flow diagram for cross reference with log sheets. At the time of balance the following procedure is followed: 1. Record the room and area served. 2. Record the size and type of terminal. 3. Record the effective area factor (K/F). This factor is obtained from manufacture literature or is calculated. If a flow hood is used to read the terminal then the K/F is set to 1.0. 4. Record the design CFM. 5. Calculate the design FPM; CFM divided by K/F. 6. Record initial terminal FPM and CFM readings. 7. Adjust each terminal to within 10% of design using volume dampers. If volume dampers are not provided then adjustments may have to be made at the terminal device. 8. For supply terminals only, adjust flow pattern to that shown on plans and schedules. 9. Record final FPM and CFM readings. 10. Prepare log sheets of readings for final report to illustrate the conditions of flow for each terminal before and after balancing. 7. Measure the total air volume by pitot tube traverse to confirm the total air delivery through the heating or cooling element. Use this new air volume in the equation to determine heating capacity in step #3. Compare the new air volume to the previous method of establishing air volume. If measurements differ greater than 10% investigate as to the reason for the inconsistency, look for possible duct leakage or system changes that where not made aware to our company. 8. If a reason for the heating capacity cannot be determined, measure the pressure drop through the heating or cooling element and verify that there is a laminar velocity across the coil. Document all findings and report the specific tests that were made in the T.A.B. Summary. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 4 of 22 CenturyLink Tukwilla Cyber Center.xlsx AP °F AK AMP BHP BTU CFM CL DB DDC DNA EAT ESP EWT FC FLA FPM FR FT HD GPM HOOD HP HZ LAT LWT MFG PH PSI PSID RPM SF SP TSP WB Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 ABBREVIATIONS PRESSURE DIFFERENTIAL DEGREES FARENHEIT CORRECTION FACTOR AMPERAGE BRAKE HORSEPOWER BRITISH TERMINAL UNIT CUBIC FEET PER MIN CENTER LINE DRY BULB TEMPERATURE DIRECT DIGITAL CONTROLS DID NOT APPLY ENTERING AIR TEMPERATURE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE FLOW COEFFECIENT FULL LOAD AMPERAGE FEET PER MINUTE FRAME DYNAMIC FEET OF HEAD GALLONS PER MINUTE MEASURED WITH FLOW HOOD HORSEPOWER HERTZ LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE MANUFACTURER PHASE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH DIFFERENTIAL ROTATION PER MINUTE SERVICE FACTOR STATIC PRESSURE TOTAL STATIC PRESSURE WET BULB TEMPERATURE 5 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARD1N&SONS MECHANICALURVI{ES Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 6 of 22 gc) 1 0 E-4 a g 4 0 o = w 0 NEBB CERTIFICATION (C) NEBB Cect. No. CenturyLink Tukwilla Cyber Center.xlsx HARDIN&SONS MECHARREAL SERVICES F-0 Hardin and Sons, Inc. WA 2120 Meridian AveeE Edgewood,98371 7 of 22 gg 44 0 0 NEBB CERTIFICATION 3-fardin & NEBB Cert. No. CenturyLink Tukwilla Cyber Center.xlsx EQUIPMENT CALIBRATION Instrument Ownership for Firm: HARDIN & SONS, INC. Date: 02/03/16 A,H Rotation Measurement 0to5000rpm ± 2% of reading OL- UTI( ± 5 rpm Mfr. / Model Number: Check Line / PLT-5000 Optical / Contact Tach Serial Number: B14C8535P 12 Months Date: 11/02/15 A Temperature Measurement Air Immersion Contact -40 to 240 deg. F (US) -40 to 115 deg. C (SI) ± 1% of reading 0.2 deg. F (US) 0.1 deg. C (SI) Mfr. / Model Number: Fluke / 50D Serial Number: 76120026 12 Months Date: 11/04/15 -40 to 240 deg. F (US) -40 to 115 deg. C (SI) ± 1% of reading 0.2 deg. F (US) 0.1 deg. C (SI) Mfr. / Model Number: Fluke / 50D Serial Number: 76120026 12 Months Date: 11/04/15 -40 to 240 deg. F (US) -40 to 115 deg. C (SI) ± 1% of reading 0.2 deg. F (US) 0.1 deg. C (SI) Mfr / Model Number: Fluke / 50D Serial Number: 76120026 12 Months Date: 11/04/15 A,H A,H Electrical Measurement Volts Amperes 0 to 600 VAC 0 to 100 Amps ± 2% of reading ± 2% of reading 1.0 Volt 0.1 Ampere Mfr / Model Number: Fluke/T5-600 Serial Number: 20410782 12 Months Date: 10/30/15 A Air Pressure Measurement 0 to 10.00 in.w.g. (US) 0 to 2500 Pascals (SI) ± 5% of reading 0.01 in.w.g. < 1 in w.g. (US) 2.5 Pa < 250 Pa (SI) 0.1 in. w.g. > 1 in. w.g (US) Mfr / Model Number: Shortridge ADM 860 Serial Number M96031 12 Months Date: 09/15/15 A Air Velocity Measurement 50 to 2500 fpm (US) 0.25 to 12.5 m/s (SI) *Not for Pitot Traverse ± 5% of reading 20 fpm (US) 0.1 m/s (SI) Mfr / Model Number: TSI Alnor/ RVA501 Serial Number RVA501524003 12 Months Date: 06/12/15 Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 8 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARDIN&SONS MECHASE9CAL SERVICES Instrument Ownership for Firm: HARDIN & SONS, INC. EQUIPMENT CALIBRATION Date: 02/03/16 A .N_ Ti ON • Humidity Measurement 10 to 90% RH 2% of reading 1% SOLUTION` LIME R�MATION Mfr. / Model Number: Extech Instruments / RH390 Serial Number: 130619936 12 Months Date: 11/04/15 A Air Volume Measurement 100 to 2000 cfm (US) 50 to 1001/s *Direct Reading Flowhood ± 5% of reading ± 5 cfm (US) Digital 1 cfm (US) Digital 0.5 l/s (SI) Mfr. / Model Number: Shortridge ADM 860 Serial Number: M00630 12 Months Date: 11/06/15 A Pitot Tubes 18" minimum, adequate length for intended use. N/A N/A Mfr. / Model Number: Several sets all sizes Serial Number: Not Required Hydronic Pressure Measurement -30" hg to 60 psi (US) -760 mm hg to 400 kPa (SI) ± 2% of reading 0.5 psi (US) 3.3 kPa (SI) Mfr / Model Number: Shortridge HDM-250 Hydrometer Serial Number: W00109 12 Months Date: 09/11/15 0 to 100 psi (US) 0 to 700 kPa (SI) ± 2% of reading 1.0 psi (US) 6.7 kPa (SI) Mfr / Model Number: Shortridge HDM-250 Hydrometer Serial Number: W00109 12 Months Date: 09/11/15 0 to 200 psi (US) 0 to 1400 kPa (SI) ± 2% of reading 2.5 psi (US) 16.7 kPa (SI Mfr / Model Number: Shortridge HDM-250 Hydrometer Serial Number W00109 12 Months Date: 09/11/15 H Hydronic Differential Pressure Measurement 0 to 100 in. w.g. 0 to 25 kPa (SI) ± 2% of reading 1.0 in. w.g. (US) 250 Pa (SI) Mfr / Model Number: Shortridge HDM-250 Hydrometer Serial Number W00109 12 Months Date: 09/11/15 0 to 100 ft. w.g. (US) 0 to 300 kPa (SI) ± 2% of reading 1.0 ft. w.g. (US) 3.0 kPa (SI) Mfr / Model Number: Shortridge HDM-250 Hydrometer Serial Number W00109 12 Months Date: 09/11/15 Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 9 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED Scope of Work: CenturyLink Tukwilla Cyber Center PCOR & Battery Room EXECUTIVE SUMMARY PROJ. # 4268 DATE: 2/3/2016 Provide Testing, Adjusting & Balancing of new and modified HVAC systems associated with this project. General Notes: There are three Air Handling Units (AHU-16, 16A, 17) that serve the same area. Design is to operate two Air Handlers at a time and have one Air Handler as backup. Each was tested for performance and results were very similar regardless of which combination of units were running at the same time. We used outlet #20 as a system representation diffuser. Airflow was stable in this duct location, not influenced by the battery room exhaust fan speed. Test #1 Units 16 & 16A in operation: Supply Diffuser #20 was measured at 519 FPM / 290 CFM, Battery Room pressure was (-)0.03" w.c. Supply Diffuser in Battery Room (#42) measured at 1180 FPM / 6,595 CFM. Test #2 Units 16A & 17 in operation: Supply Diffuser #20 was measured at 521 FPM / 290 CFM, Battery Room pressure was (-)0.04" w.c. Supply Diffuser in Battery Room (#42) measured at 1188 FPM / 6,640 CFM. Test #2 Units 16 & 17 in operation: Supply Diffuser #20 was measured at 561 FPM / 314 CFM, Battery Room pressure was (-)0.05" w.c. Supply Diffuser in Battery Room (#42) measured at 1119 FPM / 6,255 CFM. Supply Diffusers were proportioned to current capacity and load per engineer's directive with original design CFM being delivered to the Battery Room. We proportioned the system in the presence of the engineer to his directive. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 10 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center PCOR & Battery Room MOTOR NAMEPLATE Mfg. Browning HP 15.0 FR 254T RPM 1,765 Volt 460 Amp 17.7 Ph / SF 3 / 1.15 Efficiency 93.00 Power Fact. 86.00 MOTOR SHEAVE DATA Mfg. Direct Drive Model Direct Drive Pitch Direct Drive Bore Direct Drive Bushing Direct Drive FAN NAMPLATE DATA Mfg. AAON Model RN-050-3-0-EA09- 000 Size --- Serial # 201511BNCW10368 FAN SHEAVE DATA Mfg. Direct Drive Model Direct Drive Pitch Direct Drive Bore Direct Drive Belt # / C.L. DD / DD Bushing Direct Drive Motor (In/Out) DD / DD Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 AIR HANDLER TEST SHEET PROJ. # 4268 SYSTEM AHU - 16A (Air Handler) DATA ITEM PRELIMINARY FINAL PASS VOLTS 432 / 435 431 / 433 AMPS 16.9 / 17.9 16.4 / 17.4 BHP 6.18 5.98 OPERATING HZ. 1,560 1,560 FAN RPM 53 53 SP- (-) 3.54 (-) 3.41 SP+ (+) 0.68 (+) 0.76 TOTAL SP 4.22 4.17 TOTAL AIR CFM 20,177 20,177 FILTERS & COIL SP (In/Out) (-) 1.73 / (-) 3.54 (-) 0.59 / (-) 3.41 FAN SP (In/Out) (-) 3.54 / (+) 0.68 (-) 3.41 / (+) 0.76 MOTOR STARTER DATA Mfg. VFD Size --- Heaters --- Rating --- SCHEDULE DATA CFM 20,000 TSP/ESP 4.14 / 2.25 RPM 1,545 BHP 9.70 MIN OSA 6,000 REMARKS 1) Total Air CFM established by Velocity Grid Traverse of OSA Intake. 2) Fan Speed Setting - 53 Hz, Static Pressure Control. 3) Supply outlet requirement CFM - 20,000 4) Fan % of design CFM - 101 5) Unable to set Min OSA control contractor has no control of OSA damper 6) Supply fan has two motors. 11 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center PCOR & Battery Room CROSS SECTION TEST REPORT PROJ. # 4268 SYSTEM Supply AHU - 16A CROSS SECTION DATA DESIGN PRELIMINARY FINAL PASS TYPE SIZE SQ. FT. FPM CFM STATIC TEMP FPM CFM STATIC FPM CFM STATIC TEMP S.O. 33 x 95 21.77 919 20,000 --- --- 927 20,177 Atmosp. 927 20,177 Atmosp. --- PRELIMINARY VELOCITY MEASUREMENTS POSITION A B C D E F G H 1 J K L M 1 1,071 1,140 1,033 1,143 999 994 1,202 1,270 2 682 964 768 857 960 874 1,496 895 3 457 687 682 774 787 526 1,108 875 4 5 6 7 8 9 10 FINAL VELOCITY MEASUREMENTS POSITION A B C D E F G H 1 J K L M 1 1,071 1,140 1,033 1,143 999 994 1,202 1,270 2 682 964 768 857 960 874 1,496 895 3 457 687 682 774 787 526 1,108 875 4 5 6 7 8 9 10 Remarks: 1) Meaurement was taken with a Velocity Grid attached to a Shortridge Air Data Multimeter at the Outside Air Intake. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 12 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARDIN&SONS PR ECAAA'ICMLSER VICES PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center MOTOR NAMEPLATE Mfg. Baldor HP 20.0 FR 256T RPM 1,765 Volt 460 Amp 24.0 Ph/SF 3/ 1.15 Efficiency 88.00 Power Fact. DNL MOTOR SHEAVE DATA Mfg. Browning Model 2B54Q1 Pitch 5.4 Bore 1-5/8" Bushing Blackstar Q1 FAN NAMPLATE DATA Mfg. TRANE Model TCD600A40E0C8N B1A Size --- Serial # C00G21625 FAN SHEAVE DATA Mfg. Browning Model 2B5V136 Pitch 13.6 Bore 1-11 /16" Belt # / C.L. (2) BX97 / 34 1/2" Bushing B 1-11/16 Motor (In/Out) 2" / 3" Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 PCOR & Battery Room AIR HANDLER TEST SHEET PROJ. # 4268 SYSTEM AHU - 16 (Air Handler) DATA ITEM PRELIMINARY FINAL PASS VOLTS 475 476 480 475 476 478 AMPS 22.8 23.2 22.9 22.3 21.8 20.6 BHP 19.85 18.61 OPERATING HZ. 60 60 FAN RPM 706 706 SP- (-) 2.17 (-) 2.06 SP+ (+) 0.73 (+) 0.81 TOTAL SP 2.90 2.87 TOTAL AIR CFM 20,663 20,663 FILTERS & COIL SP (In/Out) (-) 1.06 / (-) 2.17 (-) 1.19 / (-) 2.06 FAN SP (In/Out) (-) 2.17 / (+) 0.73 (-) 2.06 / (+) 0.81 MOTOR STARTER DATA Mfg. Contactor Size --- Heaters --- Rating --- SCHEDULE DATA CFM 20,000 TSP/ESP Existing RPM Existing BHP Existing MIN OSA Existing REMARKS 1) Total Air CFM established by Velocity Grid Traverse of OSA Intake. 2) Fan Speed Setting - Constant Volume. 3) Supply outlet requirement CFM - 20,000 4) Fan % of design CFM - 103% 13 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center PCOR & Battery Room CROSS SECTION TEST REPORT PROJ. # 4268 SYSTEM AHU - 16 Supply CROSS SECTION DATA DESIGN PRELIMINARY FINAL PASS TYPE SIZE SQ. FT. FPM CFM STATIC TEMP FPM CFM STATIC FPM CFM STATIC TEMP S.O. 22 x 36 x 3 16.50 1212 20,000 --- --- 1252 20,663 Atmosp. 1,252 20,663 Atmosp. --- PRELIMINARY VELOCITY MEASUREMENTS POSITION A B C D E F G H I J K L M 1 1,221 1,169 1,275 1,252 1,232 1,435 2 1,278 1,179 1,304 1,240 1,360 1,303 3 1,237 1,152 1,235 1,220 1,231 1,218 4 5 6 7 8 9 10 FINAL VELOCITY MEASUREMENTS POSITION A B C D E F G H I J K L M 1 1,221 1,169 1,275 1,252 1,232 1,435 2 1,278 1,179 1,304 1,240 1,360 1,303 3 1,237 1,152 1,235 1,220 1,231 1,218 4 - 5 6 7 8 9 10 Remarks: 1) Meaurement was taken with a Velocity Grid attached to a Shortridge Air Data Multimeter at the Outside Air Intake. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 14 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARDIN&SONS MECHANICAL SERVICES PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center MOTOR NAMEPLATE Mfg. Baldor HP 20.0 FR 256T RPM 1,765 Volt 460 Amp 24.0 Ph / SF 3 / 1.15 Efficiency 93.00 Power Fact. DNL MOTOR SHEAVE DATA Mfg. Browning Model 2B54Q1 Pitch --- Bore 1-5/8" Bushing Blackstar Q1 FAN NAMPLATE DATA Mfg. TRANE Model TCD600A40E0C8N B1A Size --- Serial # C00G21626 FAN SHEAVE DATA Mfg. Browning Model 2B5V136 Pitch --- Bore 1-11/16" Belt # / C.L. (2) BX97 / 34 1/2" Bushing B 1-11/16 Motor (In/Out) 1" / 4" Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 PCOR & Battery Room AIR HANDLER TEST SHEET PROJ. # 4268 SYSTEM AHU - 17 (Air Handler) DATA ITEM PRELIMINARY FINAL PASS VOLTS 484 485 485 484 485 484 AMPS 21.6 21.4 21.2 21.5 21.4 21.6 BHP 18.79 18.86 OPERATING HZ. 60 60 FAN RPM 711 711 SP- (-) 2.06 (-) 2.06 SP+ (+) 0.42 (+) 0.42 TOTAL SP 2.48 2.48 TOTAL AIR CFM 21,357 21,357 FILTERS & COIL SP (In/Out) (-) 1.23 / (-) 2.06 (-) 1.23 / (-) 2.06 FAN SP (In/Out) (-) 2.06 / (+) 0.42 (-) 2.06 / (+) 0.42 MOTOR STARTER DATA Mfg. Contactor Size --- Heaters --- Rating --- SCHEDULE DATA CFM 20,000 TSP/ESP Existing RPM Existing BHP Existing MIN OSA Existing REMARKS 1) Total Air CFM established by Velocity Grid Traverse of OSA Intake. 2) Fan Speed Setting - Constant Volume. 3) Supply outlet requirement CFM - 20,000 4) Fan % of design CFM - 107% 15 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARDIN&SONS R4ECNAMI%ALSEAVI[ES PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center PCOR & Battery Room CROSS SECTION TEST REPORT PROJ. # 4268 SYSTEM AHU - 17 Supply CROSS SECTION DATA DESIGN PRELIMINARY FINAL PASS TYPE SIZE SQ. FT. FPM CFM STATIC TEMP FPM CFM STATIC FPM CFM STATIC TEMP S.O. 22 x 36 x 3 16.50 1212 20,000 --- --- 1294 21,357 Atmosp. 1,294 21,357 Atmosp. --- PRELIMINARY VELOCITY MEASUREMENTS POSITION A B C D E F G H I J K L M 1 1,296 1,301 1,219 1,308 1,467 1,241 1,374 2 1,216 1,422 1,372 1,222 1,260 1,271 1,146 3 1,230 1,362 1,214 1,300 1,317 1,226 1,417 4 5 6 7 8 9 10 FINAL VELOCITY MEASUREMENTS POSITION A B C D E F G H I J K L M 1 1,296 1,301 1,219 1,308 1,467 1,241 1,374 2 1,216 1,422 1,372 1,222 1,260 1,271 1,146 3 1,230 1,362 1,214 1,300 1,317 1,226 1,417 4 5 6 7 8 9 10 Remarks: 1) Meaurement was taken with a Velocity Grid attached to a Shortridge Air Data Multimeter at the Outside Air Intake. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 16 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center Collocate Room AIR OPENING TEST SHEET PROJECT 4268 SYSTEM AH U's AREA SERVED OUTLET DESIGN PRELIMINARY 2ND PASS FINAL PASS PERCENT OF DESIGN NO. TYPE SIZE AK FPM CFM FPM CFM FPM CFM FPM CFM Supply Collocate 1 SWG 14 x 14 0.56 636 375 514 288 561 314 672 376 100% Collocate 2 SWG 14 x 14 0.56 636 375 499 279 515 288 632 354 94% Collocate 3 SWG 14 x 14 0.56 636 375 758 424 605 339 651 365 97% Collocate 4 SWG 14 x 14 0.56 636 375 722 404 561 314 616 345 92% Collocate 5 SWG 14 x 14 0.56 636 375 399 223 766 429 736 412 110% Collocate 6 SWG 14 x 14 0.56 636 375 486 272 823 461 701 393 105% Collocate 7 SWG 14 x 14 0.56 636 375 485 272 885 496 654 366 98% Collocate 8 SWG 14 x 14 0.56 636 375 497 278 883 494 629 352 94% Collocate 9 SWG 14 x 14 0.56 636 375 814 456 700 392 726 407 108% Collocate 10 SWG 14 x 14 0.56 636 375 654 366 777 435 640 358 96% Collocate 11 SWG 14 x 14 0.56 636 375 607 340 690 386 732 410 109% Collocate 12 SWG 14 x 14 0.56 636 375 518 290 598 335 700 392 105% Collocate 13 SWG 14 x 14 0.56 636 375 385 216 781 437 640 358 96% Collocate 14 SWG 14 x 14 0.56 636 375 440 246 625 350 619 347 92% Collocate 15 SWG 14 x 14 0.56 636 375 554 310 559 313 617 346 92% Collocate 16 SWG 14 x 14 0.56 636 375 459 257 590 330 623 349 93% Collocate 17 SWG 14 x 14 0.56 636 375 224 125 420 235 667 374 100% Collocate 18 SWG 14 x 14 0.56 636 375 487 273 706 395 630 353 94% Collocate 19 SWG 14 x 14 0.56 636 375 228 128 319 179 562 315 84% Collocate 20 SWG 14 x 14 0.56 636 375 165 92 461 258 454 254 68% Collocate 21 SWG 14 x 14 0.56 636 375 510 286 649 363 690 386 103% Collocate 22 SWG 14 x 14 0.56 636 375 490 274 547 306 676 379 101% Collocate 23 SWG 14 x 14 0.56 636 375 367 206 442 248 744 417 111% Collocate 24 SWG 14 x 14 0.56 636 375 361 202 440 246 649 363 97% Collocate 25 Duct 24" 3.14 489 1,535 989 3,105 1086 3,410 500 1,570 102% DADU 26A SWG 7 x 19 0.63 659 415 392 247 530 334 647 408 98% DADU 26B SWG 7 x 19 0.63 659 415 380 239 375 236 636 401 97% DADU 26C SWG 7 x 19 0.63 659 415 422 266 508 320 611 385 93% DADU 27A SWG 7 x 19 0.63 659 415 527 332 571 360 655 413 99% REMARKS: 1) Terminal Velcoity was measured with a Rotating Vane Anemometer. Field established AK -Factors were calculated based on traverse measurements. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 17 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center Collocate Room AIR OPENING TEST SHEET PROJECT 4268 SYSTEM AH U's AREA SERVED OUTLET DESIGN PRELIMINARY 2ND PASS FINAL PASS PERCENT OF DESIGN NO. TYPE SIZE AK FPM CFM FPM CFM FPM CFM FPM CFM DADU 27B SWG 7 x 19 0.63 659 415 533 336 576 363 633 399 96% DADU 27C SWG 7 x 19 0.63 659 415 485 306 559 352 683 430 104% DADU 28A SWG 7 x 19 0.63 659 415 660 416 678 427 610 384 93% DADU 28B SWG 7 x 19 0.63 659 415 742 467 595 375 650 410 99% DADU 28C SWG 7 x 19 0.63 659 415 705 444 532 335 670 422 102% DADU 29A SWG 7 x 19 0.63 659 415 274 173 595 375 704 444 107% DADU 29B SWG 7 x 19 0.63 659 415 407 256 482 304 656 413 100% DADU 29C SWG 7 x 19 0.63 659 415 449 283 702 442 670 422 102% DADU 30A SWG 7 x 19 0.63 659 415 653 411 552 348 624 393 95% DADU 30B SWG 7 x 19 0.63 659 415 565 356 569 358 690 435 105% DADU 30C SWG 7 x 19 0.63 659 415 807 508 534 336 720 454 109% DADU 31A SWG 7 x 19 0.63 659 415 443 279 614 387 721 454 109% DADU 31B SWG 7 x 19 0.63 659 415 456 287 528 333 600 378 91% DADU 31C SWG 7 x 19 0.63 659 415 507 319 528 333 648 408 98% DADU 32A SWG 7 x 19 0.63 659 415 600 378 559 352 634 399 96% DADU 32B SWG 7 x 19 0.63 659 415 586 369 627 395 670 422 102% DADU 32C SWG 7 x 19 0.63 659 415 637 401 532 335 617 389 94% DADU 33A SWG 7 x 19 0.63 659 415 682 430 833 525 646 407 98% DADU 33B SWG 7 x 19 0.63 659 415 621 391 480 302 694 437 105% DADU 33C SWG 7 x 19 0.63 659 415 647 408 520 328 672 423 102% Collocate 34 Duct 24" 3.36 441 1,385 1069 3,592 608 2,043 387 1,300 94% Collocate 35 Duct 24" 3.36 441 1,385 339 1,139 691 2,322 422 1,418 102% Collocate 36 Duct 24" 3.36 441 1,385 597 2,006 812 2,728 373 1,253 90% Collocate 37 Duct 18" 1.77 508 900 672 1,189 821 1,453 501 887 99% Collocate 38 Duct 28" 4.28 647 2,770 489 2,093 633 2,709 588 2,517 91% Collocate 39 Duct 28" 4.28 647 2,770 524 2,243 646 2,765 583 2,495 90% Collocate 40 Duct 28" 4.28 647 2,770 1376 5,889 895 3,831 689 2,949 106% Cooridor 41 CD 8" Hood --- 100 --- 235 --- 198 --- 97 97% Battery 42 Duct 32" 5.59 1073 6,000 918 5,132 796 4,450 1083 6,054 101% Total 39,960 41,436 42,809 43,507 109% REMARKS: 1) Terminal Velcoity was measured with a Rotating Vane Anemometer. Field established AK -Factors were calculated based on traverse measurements. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 18 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center Battery Room MOTOR NAMEPLATE Mfg. WEG HP 2.0 FR 143/5T RPM 1,740 Volt 460 Amp 2.7 Ph/SF 3/ 1.15 Efficiency 86.50 Power Fact. 81.00 MOTOR SHEAVE DATA Mfg. Browning Model VP44 Pitch --- Bore 7/8" Bushing DNA FAN NAMPLATE DATA Mfg. Greenheck Model GB - 300 - 20 - X Size --- Serial # 14323493 FAN SHEAVE DATA Mfg. Browning Model AK104 Pitch --- Bore 1" Belt # / C.L. (1) AX42 / 10 1/2" Bushing DNA Motor (In/Out) 1" / 3" Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 AIR HANDLER TEST SHEET PROJ. # 4268 SYSTEM EF - 32 (Exhaust Fan) DATA ITEM PRELIMINARY FINAL PASS VOLTS --- 459 --- --- 459 --- AMPS--- BHP 1.85 1.93 OPERATING HZ. 60 60 FAN RPM 604 604 SP- (-) 0.39 (-) 0.42 SP+ (+) Atmosph. (+) Atmosph. TOTAL SP 0.39 0.42 TOTAL AIR CFM 6,729 6,598 MOTOR STARTER DATA Mfg. VFD Size --- Heaters --- Rating --- SCHEDULE DATA CFM 6,500 TSP/ESP 0.75 RPM 580 BHP 1.30 MIN OSA --- REMARKS 1) Total Air CFM established by SUM of air inlets. 2) Fan Speed Setting - 604 RPM and 60 Hz. 3) Exhaust inlet requirement CFM - 6,500 4) Fan % of design CFM - 102% 19 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARDIN&SONS MECHANICAL SERVICES PROJECT NAME AREA SERVED CenturyLink Tukwilla Cyber Center Battery Room AIR OPENING TEST SHEET PROJECT 4268 SYSTEM EF - 32 AREA SERVED OUTLET DESIGN PRELIMINARY 2ND PASS FINAL PASS PERCENT OF DESIGN NO. TYPE SIZE AK FPM CFM FPM CFM FPM CFM FPM CFM Exhaust Battery RM. 1 EG 13 x 13 0.85 1059 900 1012 860 1086 923 1086 923 103% Battery RM. 2 EG 13 x 13 0.85 1059 900 1047 890 1104 938 1104 938 104% Battery RM. 3 EG 15 x 15 1.14 1096 1,250 1141 1,301 1159 1,321 1159 1,321 106% Battery RM. 4 EG 15 x 15 1.14 1096 1,250 1032 1,176 1057 1,205 1057 1,205 96% Battery RM. 5 EG 13 x 23 1.52 362 550 317 482 370 562 370 562 102% Battery RM. 6 EG 13 x 23 1.52 362 550 669 1,017 347 527 347 527 96% Battery RM. 7 EG 13 x 23 1.52 362 550 362 550 392 596 392 596 108% Battery RM. 8 EG 13 x 23 1.52 362 550 298 453 346 526 346 526 96% Total 6,500 6,729 6,598 6,598 102% REMARKS: 1) Terminal Velcoity was measured with a Rotating Vane Anemometer. Field established AK -Factors were calculated based on traverse measurements. Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 20 of 22 CenturyLink Tukwilla Cyber Center.xlsx HARD IN&SONS MECHANICAL. SERVICES PROJECT NAME AREA SERVED MOTOR NAMEPLATE Mfg. Baldor HP 5.0 FR 184T RPM 1,750 Volt 460 Amp 6.7 Ph/SF 3 / 1.15 Efficiency 89.50 Power Fact. 78.00 MOTOR SHEAVE DATA Mfg. Browning Model 2VP50 Pitch 2.5 T.O. Bore 1 1 /8" Bushing DNA FAN NAMPLATE DATA Mfg. Greenheck Model LBP-54-50-X Size --- Serial # 14325013 15J FAN SHEAVE DATA Mfg. Browning Model 25.0 X 2B - SF Pitch Bore 1 3/4" Belt # / C.L. ;2)AP116 / 35" Bushing SF-1 3/4" XBP Motor (In/Out) 1" / 2" Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 CenturyLink Tukwilla Cyber Center PCOR & Battery Room AIR HANDLER TEST SHEET PROJ. # 4268 SYSTEM EF-38 (Exhaust Fan) DATA ITEM PRELIMINARY FINAL PASS VOLTS --- 335 --- --- 459 --- AMPS--- BHP 1.74 3.28 OPERATING HZ. 45 60 FAN RPM 204 273 SP- (-) 0.11 (-) 0.19 SP+ (+) Atmosph. (+) Atmosph. TOTAL SP 0.11 0.19 TOTAL AIR CFM 14,783 19,710 MOTOR STARTER DATA Mfg. VFD Size --- Heaters --- Rating --- SCHEDULE DATA CFM 20,000 TSP/ESP 0.38 RPM 277 BHP 2.72 MIN OSA --- REMARKS 1) Total Air CFM established by RPM (273/277)*20,000 = 19,710 CFM 2) Fan Speed Setting - 273 RPM and 60 Hz. 3) Exhaust inlet requirement CFM - 20,000. 4) Fan % of design CFM - 99% 21 of 22 CenturyLink Tukwilla Cyber Center.xlsx PROJECT NAME AREA SERVED MOTOR NAMEPLATE Mfg. Baldor HP 5.0 FR 184T RPM 1,750 Volt 460 Amp 6.7 Ph / SF 3 / 1.15 Efficiency 89.50 Power Fact. 78.00 MOTOR SHEAVE DATA Mfg. Browning Model 2VP50 Pitch 2.5 T.O. Bore 1 1/8" Bushing DNA FAN NAMPLATE DATA Mfg. Greenheck Model LBP - 54 - 50 - X Size --- Serial # 14325014 15J FAN SHEAVE DATA Mfg. Browning Model 25.0 X 2B - SF Pitch Bore 1 3/4" Belt # / C.L..2)AP116 / 35" Bushing SF-1 3/4" XBP Motor (In/Out) 1" / 2" Hardin and Sons, Inc. 2120 Meridian Ave E. Edgewood, WA 98371 CenturyLink Tukwilla Cyber Center PCOR & Battery Room AIR HANDLER TEST SHEET PROJ. # 4268 SYSTEM EF - 39 (Exhaust Fan) DATA ITEM PRELIMINARY FINAL PASS VOLTS --- 334 --- --- 429 --- AMPS--- BHP 1.68 2.99 OPERATING HZ. 45 60 FAN RPM 206 274 SP- (-) 0.08 (-) 0.14 SP+ (+) Atmosph. (+) Atmosph. TOTAL SP 0.08 0.14 TOTAL AIR CFM 14,837 19,783 MOTOR STARTER DATA Mfg. VFD Size --- Heaters --- Rating --- SCHEDULE DATA CFM 20,000 TSP/ESP 0.38 RPM 277 BHP 2.72 MIN OSA --- REMARKS 1) Total Air CFM established by RPM (274/277)*20,000 = 19,783 CFM 2) Fan Speed Setting - 274 RPM and 60 Hz. 3) Exhaust inlet requirement CFM - 20,000. 4) Fan % of design CFM - 100% 22 of 22 CenturyLink Tukwilla Cyber Center.xlsx UP TO 36/24 — UP TR RTU-41 36/24 111,1C; DOCK 12/12 ENDED TO WALL 18x16 1800 CFM 28/16 STORAGE ROOV 10 200 MEN [ AC11 r• ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU— 17 1-1 24/24 FOti1210.111 R;••!11' 66/28 (2" SL) UP TO RTU-17 72/40 CLEAR OPENING ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-16 24/24 66/28 (2" SL) UP TO RTU-16 E'REAK R0.71 - !r , i (-31_9 -1-1- W0MEN 11•00..voic+Lor 1 1.61, 1K147 ,t • 91 24x24_,.. T. trip 0+ 220 MD-19 • 440 - 22.'0 up 8 (YP) MD-18 • 240 600W DUCT LOOP BOD AT 16'—O' ABOVE, SLAB. (14'-6" AFF) . . 600 65x46 SA UP " POC TIRANSIN 60-0 60-0 TO 48*0 0 TRANSITION 48" 4811 TO 36"0 36*0 )(2 54x54 UP TO EXH FAN I MD-20I 1< IFSD— 191 (rYP) c CenturyLink air balance calculation, 1/19/2016, revl outlet location original load basis calc 40000 load fraction calc cfm rounded final 1 2 3 4 5 6 7 8 9 10 11 12 old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz old horz 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 680 existing load is unknown, assume 2,000 amps 1 each 2000 Amps 52.8 V 105,600 W 360,096 btuh 30 tons 0.22 8,973 9000 375 375 375 375 375 375 375 375 375 375 375 375 375 375 375 375 375 375 375 375 3/.5 375 375 375 13 14 15 16 17 18 19 20 21 22 23 24 25 pcor 1500 8 each DADU's, each 8 each 1250 26 pcor 1500 getting 1,500 cfm for a 18,000 W each :1250 27 pcor 1500 total of 12,000 cfm 144,000 W 1250 28 pcor 1500 491,040 btuh 1250 29 pcor 1500 41 tons 0.31 12,236 10000 1250 30 pcor 1500 293 cfm/ton 1250 31 pcor 1500 1.250 32 pcor 1500 1250 33 asr 3000 two ASR 9010 routers 2 each 1535 9,312 W each 18,624 W 63,508 btuh 5 tons 0.04 1,583 1500 34 ip west 2600 three rows, each with a 3 each 1.,385 35 ip west 2600 1,200 Amp BDFB limited to 960 Amps 1.,385 36 ip west 2600 80% capacity which is 960 52.8 V 1,385 37 ip east 5200 Amps. 152,064 W 2,770 38 ip east 5200 518,538 btuh 2,770 39 ip east 5200 43 tons 0.32 12,921 12465 2,770 40 inverters 1600 Benning model 4 each 900 BL12525361020 nominal 565 amps 2500 VA. 4 each at 33A, 120V ouput, 565 Amp 48 VDC 0.1 10% 48VDC input with 10% loss 10,848 W 36,992 btuh 3.1 tons 0.02 922 41 corridor 100 0 tons 100 :1.00 42 battery 6000 10% of 7,500 Amps 7500 Amps 6000 52.8 V 0.1 10% 39,600 W 135,036 btuh 11 tons 0.08 3,365 total 134 tons 40100 10000 CENTURYLINK TUKWILA BATTERY ROOM AND SWITCH AREA HVAC CONTROL SEQUENCE OF OPERATION revision date author comments 1 10/5/15 R. Jones, KDWS original Control Sequence The Switch and Battery Room contain the following equipment controlled by the BAS 1. Existing rooftop DX packaged AC units RTU-16 and RTU-17. 2. New rooftop DX packaged AC unit RTU-16A. 3. New exhaust fan EF-32 dedicated for the battery room. 4. New economizer relief fans EF-38 and EF-39 at the Switch. General 1. The switch and battery rooms have continuous cooling loads. The new RTU-16A shall operate simultaneously with either RTU-16 or RTU-17 to provide cooling to the switch area and cooling/make-up air to the battery/rectifier room. a. The combined air handling system is an "adjustable" constant volume two zone system. The supply air temperature is controlled to satisfy the Switch Area, air flow to the battery/rectifier room is manually balanced to satisfy the room load, total system volume is adjusted by changing RTU-16A static pressure set point. b. RTU's 16 and 17 have constant volume (no vfd's) supply fans. RTU's 16 and 17 shall be rotated as lead lag to even out operating hours. c. RTU-16A shall modulate supply fan speed (VFD) to maintain either a minimum discharge duct static pressure or minimum fan speed. Minimum fan speed for RTU-16A is intended to ensure adequate supply airflow through the DX coil. Do to the nonsymmetrical supply duct configuration it is necessary to use three different RTU-16A duct static pressure for the different combination of RTU's running: i. RTU-16A with RTU16. (determine set point during air balance) ii. RTU-16A with RTU17. (determine set point during air balance) iii. RTU-16A in solo operation (use the higher of the two set points above) d. RTU failure modes: i. RTU-16 and 17 are lead/lag. If either unit fails rotate to the other unit. ii. If RTU-16A fails, operate both 16 and 17. iii. If both 16 and 17 fail, RTU-16A continues to operate and reaches full fan speed in an attempt to maintain duct static pressure set point. 2. Air Side Economizer a. The BAS shall modulate the new economizer dampers (OA & RA) at RTU-16 & RTU-17 to maintain mixed air temperature set point via dry-bulb differential temperature economizer control logic. DX coils at the RTU's are controlled by their internal controllers. Fail positon of RTU-16 & 17 dampers shall be OA closed, RA open. b. RTU-16A shall operate on stand-alone economizer controls furnished with the RTU. c. Economizer relief fans EF-38 & EF-39 shall stage to relieve economizer air from the building. Anticipate interference between RTU-16A's integral economizer relief controls and those performed by the BAS — tune the BAS economizer relief control loop to react slowly to building pressure changes caused by RTU-16A. i. The first stage shall be to modulate EF-38 & 39 isolation dampers open. ii. The second stage shall be to operate one of the two fans (EF-38 & 39) at minimum vfd speed. iii. Third stage is to operate the second fan at minimum speed. iv. Fourth speed is to modulate EF-38 & 39 simultaneously. Considering the large amount of exhaust air from the battery room and the apparent negative pressurization of adjacent spaces, it seem likely that EF-38 & 39 will need to reach full speed. 3. Battery Exhaust fan EF-32 shall modulate from a fixed minimum speed to maintain a battery room negative static pressure of 0.05 inches WC. Supply air into the battery room will be manually balanced with future adjustments to increase supply air volume as the DC plant load growth occurs. a. BAS shall monitor the Battery/Rectifier room temperature and alarm high and low temps to the operator. 4. Alarms and set points: reuse from existing sequence for RTU-16 and 17. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0103 DATE: 10/12/15 PROJECT NAME: CENTURYLINK SITE ADDRESS: 6101 S 180 ST Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: Building Division Public Works n PO 10\16 Fire Prevention Structural ❑ Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 10/13/15 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 11/10/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only s, CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0103 DATE: 08/12/15 PROJECT NAME: CENTURYLINK SITE ADDRESS: 6101 S 180 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT Olt e.(9-1 Building Division Public Works ❑ 41,0C, 9—X0—IS-- Fire Prevention 11 Planning Division M Structural Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/18/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 09/15/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 c(10', PROJECT NAME: SITE ADDRESS: tp D( J. 04 (ft- PERMIT NO:MI j ` O�Db✓ ORIGINAL ISSUE DATE: t4 I REVISION LOG REVISION NO. DATE RECEIVED STAFF IN . LS ISSUED DATE STAFF INITIALS J Summary of Revision: tel #te to Aygill' Received by ! /jj,ly, —(p REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10/09/2015 Plan Check/Permit Number: M15-0103 Response to Incomplete Letter # Response to Correction Letter # ✓ Revision # I after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: CENTURYLINK TUKWILA Project Address: 6101 SOUTH 180TH STREET Contact Person: AMANDA MOORE Phone Number: (253) 872-5665 Summary of Revision: ADDITIONAL DUCT DEM, NEW DUCT, SUPPLY GRILLE AS SHOWN CLOUDED ON REVISED SHEET M2.1. INCREASED DEMOLITION IS SHOWN CLOUDED ON M1.1. THESE CHANGES WILL DELIVER COOLING TO THE PAIR OF NEW CISCO ASR 9010 ROUTERS. DELETE THE 32" FIRE SMOKE DAMPER SHOWN IN THE WALL AT GRIDLINE 3 NORTH OF GRIDLINE E. THIS WALL IS NOT FIRE RATED. i cEWED CITif OF TUK'M A OCT1t c'EflikiliT CENTER Sheet Number(s): M 1.1; M2.1 "Cloud" or highlight all areas of revision including date o revisio Received at the City of Tukwila Permit Center by: Entered in Permits Plus on H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Rcviscd: May 2011 EMERALD AIRE INC Page 1 of 2 Home Inicio en Espanol Contact Search L&I A-Z Index Help My Secure L&1 Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries EMERALD AIRE INC Owner or tradesperson Principals HAPPE, DOUGLAS A, PRESIDENT RIDGE, JOHN PATRICK, VICE PRESIDENT RICHARDS, RON, SECRETARY (End: 06/01/2000) DUPUIS-FRICKE, LINDA, PRESIDENT (End: 12/31/1999) HAPPE, DOUGLAS A, PRESIDENT (End: 12/31/1999) TREMAINE, DAVIS WRIGHT, AGENT (End: 12/31/1999) Doing business as EMERALD AIRE INC WA UBI No. 600 591 552 5108 D STREET NW AUBURN, WA 253-872-5665 KING County Business type Corporation Governing persons DOUGLAS HAPPE JOHN RIDGE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EMERAAI055BL Effective — expiration 01/13/1995— 04/01/2017 Bond ................. THE HANOVER INSURANCE COMPANY Bond account no. 1977929 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 01/06/2011 01/01/2011 Expiration date Until Canceled Bond history Insurance .............................. American Fire & Casualty Co Policy no. $1,000,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600591552&LIC=EMERAAI055BL&SAW= 9/4/2015 SHEET NOTES 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY ALL DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. ED XFMI OEN P4 500A r3US PUGT 67 07 66 06 65 05 64 04 P3 LI3 G3 03 62- 02 GI SI GG P2 PI Ts2 L OEN I I 6LI 4000A 1 US PUGT AT6 GI D XFMR rPI N CO I11 CO N) UP TO Jr 34/20 48/42 PLENUM J h a 7- N CO N) II I 36/24 IL_1 ILJ RTU-2 • 36/24 'I UP TO UP TO LOADING DOCK RTU-4 • II I IJ� II I 36/24 IL1 18x16 1800 CFM STORAGE ROOM M EN AC1 I1r '1 24/24 —72/40—CLEAR OPEN] • ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-17 160 14/14 680 CFM EACH (TYP OF 59) 220 24/24 LI EQUIPMENT ROOM 66/28 (2" SL) UP TO RTU-17 RTU —17 / 4 240 220 240 160 TYP 8 160 t 30/18 TYPICA 160 220 220 160 72/40 CLEAR OPENING ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-16 24/24 66/28 (2" SL) UP TO RTU-16 440 MD-181• 440 600W DUCT LOOP B0D AT 16'-0" ABOVE SLAB. (14'-6" AFF) 0 (D LOCKER BREAK ROOM WOMEN 0 1_, 0 0 J 1 1 160 /.17 RTU —16 / f 600 •IMD-20 240 • IFSD-19 \AAN'b r / 240 COL pg, CORRIDOR /7/4 B.O.D. 12' —0" A.F.F. (TYP.) 2/A))///// CATE ROOM 4. 4. 240 c C 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, ETC. NECESSARY TO COMPLETE THIS PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. 4. EXISTING INFORMATION SHOWN ON DRAWING HAS BEEN TAKEN FROM EXISTING DRAWINGS PROVIDED BY THE OWNER AND/OR CURSORY FIELD SKETCHES TAKEN FROM EXISTING FILED SKETCHES AND OBSERVATIONS. KDW SALAS O'BRIEN AND THEIR REPRESENTATIVES ARE NOT RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OR CONFORMANCE WITH CODES OF ANY WORK SHOWN AS EXISTING. 5. ALL TELECOMMUNICATIONS EQUIPMENT TO REMAIN ON—UNE AND FUNCTIONING AT ALL TIMES. CONTRACTOR TO PROTECT & MAINTAIN POWER TO ALL EQUIPMENT SCHEDULED TO REMAIN FOR THE DURATION OF CONSTRUCTION. 6. SCHEDULE ALL WORK OVER, NEAR OR AFFECTING NETWORK EQUIPMENT WITH CENTURY LINK ON —SITE WORK FORCE PERSONNEL. COMPLETE "METHODS OF PROCEDURE" FOR WORK AS DIRECTED BY AT&T IN ACCORDANCE WITH AT&T STANDARDS. 7. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 8. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 9. CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION, BRACING & SHORING OF EXISTING AND NEW EQUIPMENT OR MATERIALS UNTIL SUCH TIME IT IS PERMANENTLY SUPPORTED OR IS READY FOR REMOVAL DURING CONSTRUCTION, WHETHER SCHEDULED FOR DEMOLITION OR REUSE. 10. PROVIDE EQUIPMENT PROTECTION ABOVE ALL NETWORK EQUIPMENT (INCLUDING BUT NOT LIMITED TO CABUNG, BUS, CABLE TRAY, EQUIPMENT BAYS, RECTIFIERS, BATTERIES, INVERTERS, DISTRIBUTION PANELS, ETC.). WHEN WORKING ABOVE EQUIPMENT, ALL PROTECTION SHALL BE COORDINATED WITH CENTURY UNK PERSONNEL TO ENSURE THAT THE PROTECTION WILL NOT BLOCK ACCESS TO EQUIPMENT OR CAUSE OVERHEATING. PROVIDE TEMPORARY COOLING AS REQUIRED. CONTRACTOR TO SUBMIT DESIGN OF ALL TEMPORARY DUST BARRIERS TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. FLAG NOTES CONVERT SUPPLY PLENUM BELOW CEILING INTO EXHAUST. REMOVE FSD, REF ARCH FOR INFILL OF WALL AND DEMOLITION OF GWB ENCLOSURE. RECONNECT 24"O TO EXHAUST, SEE M2.1. REMOVE EF-7 AT ROOF DEMOLISH LOW WALL GRILL. REMOVE SHOWER, SEE M2.1 FOR NEW MOP SINK. ISSUES / REVISIONS NO. DESCRIPTION DATE BY 1 60% OWNER REVIEW 04/07/15 RJJ REVISIONS No changes shall bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisiart:, l:{tl requ r cn1 may in:,'ude additional 1=+: n i3C3 2 3 100% OWNER REVIEW BID SET 05/15/15 05/18/15 RJJ RJJ SERA1-3.4717 P P. IT ra; ^,. Rom:: iiED FOR: Q mechanical )2rEt etrical %Plumbing ,KJ C CS Piping FILE COP Permit No. M\ 03 4 5 PERMIT SET PR-1 08/11/15 08/12/15 RJJ RJJ 6 PR-2 09/23/15 RJJ 1600 7TH AVE.. SEATTLE, WASIINGTON OFFICE OF THE DIR. PROPERTY MGIIT. The Women addled her* shave .d a 6 dord to teadlatlad puma It U .aak for owe by ou9ndnd npwaaialhee d Cakattilt Plan review approval is subject to errors and om ssior. Approval rdf construction documents does not auhorim the violation of any adopted coda or ordinance. Rece st of approved Field Cody and conditions is acknowledged. 50241 By; Date (0103 ( )15 REV!' City of Tukwila BUILDING DIVISION KDWSA . O'BRIEN 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p. 206.547.1940 f. 206.547.8212 www.kdw.net kiWth CenturyLink DESCRIPTION BUILDING ID O NSULTANT FIRM REVLEWED FOR CODE COMPLIANCE APPROVED OCT 2 1 2015 • M 12P City of Tukwila t BUILDING DIVISION HtutiiVEO CITY OF TUKWILA OCT 1, 2 2015 PERMIT CENTER FLOOR BUILDING NAME TUKWILA CYBER CENTER STREET AfOREss 6101 SOUTH 180TH STREET CITY. STATE TUKWILA, WA 98188 MECHANICAL DEMOLITION PARTIAL FLOOR PLAN CONSULTANT NAME KDW SALAS O'BRIEN CONSULTANT NAME MECHANICAL DEMOLITION PARTIAL FLOOR PLAN SCALE: 1/8" = 1'-0" 0 4' e' 16' PLAN NORTH DRAWN BY JCL DATE 04/07/15 CHECKED BY RJJ CASE NUMBER JOB NO. 150241 REVISED BY AS NOTED DRAWING NO. SHEET NO. M1.1 Glair SHEET NOTES 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY ALL DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. 0 XFMf OEN P4 500A f5US PUGT 67 07 G6 e6 65 65 64 e4 P3 LI' G3 03 62 02 GI 01 GG P2 PI T02 L OEN 1,1 I 6LI 4000A I3U5 PUGT AT5 GI n n 44 XI=MR TPI 34/20 1I 36/24 48/42 PLENUM TTTTT N 0 UP TO r_ J RTU-2 • } 36/24 1 1- 24/24 x UP TO UP TO TT RTU-4 • AC1 • 72/40 CLEAT U1"t1VI ON TOP OF DUCT 36" CLR MIN ABOVE 160 680 CFM EACH (TYP OF 59) 220 *11 72/27 (2" SL) UP TO RTU-17 24/24 36/24 111 I I rr—C r II i tTfT LOADING DOCK 12/12 EXTENDED TO WALL 18x16 1800 CFM STORAGE ROOM MEN 14x14 SQUARE TO ROUND TRANSITION J EQUIPMENT ROOM 66/28 (2" SL) UP TO RTU-17 RTU —17 160 220 54x54 UP TO 14/14 EXH FAN \ 240 220 160 N r) t t t 240 220 160 I 180W\ TYf fCAL 72/40 CLEAR OPENING ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-16 24/24 6 66/28 (2" SL) UP TO RTU-16 x BREAK ROOM Cr >MOPLJI 7\ ,�24x 30x30 UP TO NEW EF-32 (WAS EF-7) WOMEN 0 II H MD-19 440 t • ttt CNI 600W DUCT LOOP BOD AT 16'-0" ABOVE SLAB. ® (14'-6" AFF) 22"0 (TYP) POC (TYP) MD-18 440 • 0 CD CO 600 60x30 SO 60x30 18"0� (TYP) 65x46 SA UP POC • MD-20 17,1 ,,,i U'\— TRANSITION _�,V_ 60"0 60"0 TO 48"0 C 24"0 0 28"0 I - TRANSITION 0 48 0 48"0 TO 36"0 �I '.....,__ 36"0 COLLOCAT R M 24"0 O 18"0 CORRIDOR 54x54 UP TO EXH FAN f • IFSD-19 44"0 c c 6 3. IT IS THE CONTRACTOR'S RESPONSIBIUTY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, ETC. NECESSARY TO COMPLETE THIS PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. 4. EXISTING INFORMATION SHOWN ON DRAWING HAS BEEN TAKEN FROM EXISTING DRAWINGS PROVIDED BY THE OWNER AND/OR CURSORY FIELD SKETCHES TAKEN FROM EXISTING FILED SKETCHES AND OBSERVATIONS. KDW SALAS O'BRIEN AND THEIR REPRESENTATIVES ARE NOT RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OR CONFORMANCE WITH CODES OF ANY WORK SHOWN AS EXISTING. 5. ALL TELECOMMUNICATIONS EQUIPMENT TO REMAIN ON—LINE AND FUNCTIONING AT ALL TIMES. CONTRACTOR TO PROTECT & MAINTAIN POWER TO ALL EQUIPMENT SCHEDULED TO REMAIN FOR THE DURATION OF CONSTRUCTION. 6. SCHEDULE ALL WORK OVER, NEAR OR AFFECTING NETWORK EQUIPMENT WITH CENTURY UNK ON —SITE WORK FORCE PERSONNEL. COMPLETE "METHODS OF PROCEDURE" FOR WORK AS DIRECTED BY AT&T IN ACCORDANCE WITH AT&T STANDARDS. 7. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 8. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 9. CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION, BRACING & SHORING OF EXISTING AND NEW EQUIPMENT OR MATERIALS UNTIL SUCH TIME IT IS PERMANENTLY SUPPORTED OR IS READY FOR REMOVAL DURING CONSTRUCTION, WHETHER SCHEDULED FOR DEMOLITION OR REUSE. 10. PROVIDE EQUIPMENT PROTECTION ABOVE ALL NETWORK EQUIPMENT (INCLUDING BUT NOT LIMITED TO CABLING, BUS, CABLE TRAY, EQUIPMENT BAYS, RECTIFIERS, BATTERIES, INVERTERS, DISTRIBUTION PANELS, ETC.). WHEN WORKING ABOVE EQUIPMENT, ALL PROTECTION SHALL BE COORDINATED WITH CENTURY UNK PERSONNEL TO ENSURE THAT THE PROTECTION WILL NOT BLOCK ACCESS TO EQUIPMENT OR CAUSE OVERHEATING. PROVIDE TEMPORARY COOUNG AS REQUIRED. CONTRACTOR TO SUBMIT DESIGN OF ALL TEMPORARY DUST BARRIERS TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. D FLAG NOTES > 32"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90. > CONICAL TAP 18"0, ACCUDUCT CT. D 36"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90. > 24"0 ELBOW DOWN TO SQ/RD TRANSITION AND 24x24 TITUS 350RL SUPPLY GRILLE, 2600 CFM. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. > 32"0 TRANSITION TO 32x32 WITH FSD AND ELBOW TO BATTERY RM HIGH WALL SUPPLY. SEE DETAIL M5.1. > REPLACE SUPPLY GRILLES WITH SCREENED OPENINGS, TYPICAL 4. > 18"0 5 CORE 90 DEGREE ELBOW, ROUND TO SQUARE TRANSITION, 20x14 CONNECTION AT DADU CABINET. PROVIDE RUSKIN MD-35 VOLUME DAMPER. > 44"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90. > 65x46 UP THRU ROOF. PROVIDE 90 DEGREE RECT ELBOW WITH AIR FOIL TURNING VANES. I> RECTANGULAR TO ROUND TRANSITION, ACCUDUCT SQ RD. PROVIDE MOP SINK, FIAT MODEL TSBC1612, 36x36x12 INCH SIZE WITH MODEL 830AA SERVICE SINK FAUCET. EXTEND HOT AND COLD WATER FROM LOCATION OF EXISTING SHOWER. 1> 22"0x18"0x18"0 TEE, DOWN TO, ROUND TO SQUARE TRANSITION, 20x14 CONNECTION AT DADU CABINET. 1> 28"0 ELBOW DOWN TO SQ/RD TRANSITION AND 24x48 TITUS 350RL SUPPLY GRILLE, 5200 CFM. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. 28"0 DOWN TO SQ/RD TRANSITION AND 24x48 TITUS 350RL SUPPLY GRILLE. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. 18"0 DOWN TO SQ/RD TRANSITION AND PROVIDE 20x20 TITUS 350RL SUPPLY GRILLE, 1600 CFM. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. 24"0 DOWN TO SQ/RD TRANSITION AND 24x48 TITUS 350 RL SUPPLY GRILLE, 3,000 CFM. PROVIDE MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. GRILLE HEIGHT APPROX 8' AFF. 1> COORDINATE WITH ELEC TO RELOCATE THREE SMALL CONDUITS ONTO ADJACENT WALL TO MAKE ROOM FOR THE SUPPLY GRILLE. • ISSUES / REVISIONS NO. DESCRIPTION 1 60% OWNER REVIEW 2 100% OWNER REVIEW DATE 04/07/15 05/15/15 BY RJJ RJJ 3 4 5 6 BID SET PERMIT SET PR-1 PR-2 05/18/15 08/11/15 08/12/15 09/23/15 RJJ RJJ RJJ RJJ 1600 7I11 AVE., SEATRE, WASIINGTON OFFICE OF TlE fit. PROPERTY MGMT. iM idemnlbe ant** bee should id be &dosed b unabewaed onme. Its mead for en by aelhotMN ninerbibse d Cortina* KDWS LAS0'BRIEN 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p. 206.547.1940 f. 206.547.8212 www.kdw.net CONSULTANT FIRM REVIEWED FOR CODE COMPLIANCE APPROVED OCT 21 2015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 1.2 2015 PERMIT CENTER 150241 ke ro 'e ►` CenturyLink BUILDING ID FLOOR BUILDING NAME litttl ADDRESS CITY, STATE TUKWILA CYBER CENTER 6101 SOUTH 180TH STREET TUKWILA, WA 98188 DESCRIPTION MECHANICAL PARTIAL FLOOR PLAN CONSULTANT NAME CONSULTANT NAME 1 MECHANICAL PARTIAL FLOOR PLAN SCALE: 1/8" = 1'-0" 0 4' 8' 16' PLAN NORTH JOB NO. KDW SALAS O'BRIEN DRAWN BY JCL CASE NUMBER DATE 150241 M2.1 MECHANICAL SCHEDULES VFD SCHEDULE SYMBOL LOCATION EQUIPMENT SERVED MANUFACTURER MODEL NO. ELECTRICAL MOTOR HP DISCONNECT BYPASS SERVICE SWITCH AC LINE REACTORS ENCLOSURE REMARKS VFD-EF-32 ROOF EF-32 SQUARE 0 E-FLEX EFDEH4VYA07B08A09 460/60/3 2 YES YES YES 5% NEMA-3R SEE NOTES VFD-EF-37. ROOF. EF-37 SQUARE D. E-FLEX EFDFH4VYAO7B08A09 460/60/3 5 YES . YES . YES 3% NEMA-3R SEE NOTES VFD-EF-38 ROOF EF-38 SQUARE D E-FLEX EFDFH4VYA07B08A09 460/60/3 5 YES YES YES 3% NEMA-3R SEE NOTES NOTES: (1) FURNISH TO ELECTRICAL FOR MOUNTING AT ROOF VFD 05/19/15 DAMPER SCHEDULE LOCATION EQUIPMENT SERVED FUNCTION DAMPER TYPE BLADE ARRANGEMENT SIZE W X H DESIGN AIRFLOW CFM MANUFACTURER AND MODEL LEAKAGE CLASS REMARKS RTU 16A SUPPLY DUCT RTU-16A ISOLATION AIRFOIL PARALLEL 46 X 65 20,000 RUSKIN CD-60 AMCA 1A BATTERY ROOM SUPPLY AIR DUCT BATTERY RM BALANCING AIRFOIL OPPOSED 32 X 32 6,000 RUSKIN CD-60 AMCA 1A FIT WITH QUADRANT HANDLE FOR MANUAL BALANCING RTU 16 RETURN AIR RTU-16 ECONOMIZER AIRFOIL PARALLEL 72 X 27 20,000 RUSKIN CD-60 AMCA 1A RTU 16 OUTDOOR AIR RTU-16 ECONOMIZER AIRFOIL PARALLEL 60 X 28 20,000 RUSKIN CD-60 AMCA 1A RTU 17 RETURN AIR RTU-17 ECONOMIZER AIRFOIL PARALLEL 72 X 27 20,000 RUSKIN CD-60 AMCA 1A RTU 17 OUTDOOR AIR RTU-17 ECONOMIZER AIRFOIL PARALLEL 60 X 28 20,000 RUSKIN CD-60 AMCA 1A EF-37 DUCT BELOW ROOF EF-37 ISOLATION AIRFOIL OPPOSED 54 X 54 20,000 RUSKIN CD-60 AMCA 1A EF-38 DUCT BELOW ROOF EF-38 ISOLATION AIRFOIL OPPOSED 54 X 54 20,000 RUSKIN CD-60 AMCA 1A EXHAUST FAN SCHEDULE SYMBOL BMS NUMBER SYSTEM SERVED CONSTRUCTION TYPE DRIVE TYPE OPPERATING CONDITIONS MOTOR OPER. WEIGHT LBS _ DESIGN BASIS REMARKS EFF % HP INSULATION TYPE NOMINAL RPM VOLTS/ PHASE FLOW CFM STATIC IN WC SPEED RPM BHP EF-32 reuse existing BATTERY ROOM ROOF DOWNBLAST BELT 6500 0.75 580 1.3 2 F 1750 460/3 320 GREENHECK GB-300 SEE NOTES 1, 2, 3 EF-37 EF-04026-RT37 ECONOMIZER RELIEF ROOF LOUVERD PH BELT 20000 0.375 277 2.72 5 F 1750 460/3 600 GREENHECK LBP 54 SEE NOTES 2 & 3 EF-38 EF-04026-RT38 ECONOMIZER RELIEF ROOF LOUVERD PH BELT 20000 0.375 277 2.72 5 F 1750 460/3 600 GREENHECK LBP 54 SEE NOTES 2 & 3 NOTES: (1) EF32 REPLACES A SMALLER EF-7, PROVIDE NEW CURB AND DUCT WORK. COORDINATE LARGER ROOF PENETRATION, ELECTRICAL, AND CONTROLS. FAN RUNS CONTINUOUSLY AND DOES NOT REQURIE A BACKDRAFT OR ISOLATION DAMPER. (2) FURNISH FANS WITH ROOF CURBS (3) PROVIDE VFD COMPATIBLE MOTORS AIR BALANCE SCHEDULE SYMBOL EXISTING OR NEW UNIT LOCATION UNIT SERVICE AREA TOTAL SA CFM TOTAL RA CFM MIN OA CFM NON- RECIRC EXH CFM ZONE PRESSURIZATION CFM REMARKS RTU-16 EXISTING ROOF PCOR & BATTERY 20,000 20,000 500 500 500 RTU-17 EXISTING ROOF PCOR & BATTERY 20,000 20,000 500 500 500 RTU-16A NEW ROOF PCOR & BATTERY 20,000 14,000 5,000 6,000 - 6000 LOST TO CONTINUOUS BATTERY ROOM EXHAUST EF-32 NEW ROOF BATTERY - - - 6,500 BATTERY ROOM EXHAUST, VFD MODULATES SPEED EF-37 NEW ROOF PCOR - - - 20,000 ECONOMZIER EXHAUST, VFD MODULATES. SPEED. EF-38 NEW ROOF PCOR - - - 20,000 ECONOMZIER EXHAUST, VFD MODULATES SPEED NOTES: (1) RTU 16A, 16 ,& 17 UNITS ARE TIED TOGETHER IN A COMMON SUPPLY DUCT TO PROVIDE N+1 COOUNG OF 40,000 CFM. 16A OPERATES CONTINUOUSLY ALONG WITH EITHER 16 OR 17. 6,000 CFM OF SUPPLY AIR GOES INTO THE BATTERY ROOM WHERE IT IS EXHAUSTED BY EF-32. ECONOMIZER EXHAUST FANS EF-37 & 38 REMOVE THE OA SUPPLIED BY RTU'S 16 & 17 DURING ECONOMIZER MODE BY MODULATING TO MAINTAIN SPACE PRESSURE. REVIS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revision3 will require a new plan submittal and may in:,ude additional plan review fees. 'SEPARATE PERMIT REQUIRED FOR: Cl Mechanical ill ectricat Q�P1umbing Was Piping • City of Tukwila BUILDING DIVISION .5 - 0103 Plan review approval is eubizzt to errors and omissions. Approval of construction documents does not auk the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: 09-Oj-!5 City of Tukwila - BUILDING DIVISION AIR HANDLING UNIT SCHEDULE SYMBOL AREA SERVED EXISTING OR NEW MANUFACTURER AND MODEL SUPPLY AIRFLOW CFM MINIMUM OA CFM UNIT ELECTRICAL SUPPLY FAN EXHAUST FAN COOUNG COIL E ENERGY CODE SEE NOTE 4 FILTERS TYPE OPERATING BSME # REMARKS VOLTAGE/ PHASE FLA MCA MOCP , FAN FAN DRIVE FAN MAX FAN FAN FAN PRESSURE SUPPLY FAN MOTOR FAN QUANTITY DRIVE TYPE SPEED RPM BLADE PITCH DEGREES MOTOR BHP MOTOR NOMINAL MOTOR EFF VOLTAGE/ PHASE TOTAL SENS AIRSDE CAPACITY MBH CAPACITY MBH VELOCITY FPM ENTERING F DB/WB LEAVING F DB/WB ROWS FINS FPI PD IN WC EER IEER PRE -FILTER TOTAL FILTER WEIGHT LBS TYPE QUANTITY TYPE SPEED RPM SPEED RPM EFF % DISCHARGE TSP ESP QTY EACH BHP HP FLA EFF % VOLTAGE/ PHASE RTU-16 PCOR & BATTERY RM EXISTING TRANE 20,000 0 460/3 1 1 20 EXISTING DX COOUNG COIL 8.6 8.9 6,300 RTU-17 PCOR & BATTERY RM EXISTING TRANE 20,000 0 460/3 1 1 20 EXISTING DX COOLING COIL 8.6 8.9 6,300 RTU-16A PCOR & BATTERY RM NEW BASIS ANON RN050 20,000 6,000 460/3 130 135 150 BACKWARD CURVED 2 DIRECT 1545 1800 66 PLENUM 4.14 2.25 2 9.70 15 21.0 0.9 460/3 2 DIRECT 1136 20 1.33 2 87.5 460/3 603 458 457 75/64 53.7/53.5 4 14 0.52 11.1 12.7 2" MERV 8 4" MERV 15 6,840 16A 01026-RT40 SEE NOTES NOTES: 1. BASIS OF DESIGN SELECT RTU-16A 2. PROVIDE RTU-16A WITH 100% 3. PROVIDE RTU-16A WITH FAN SHAFT 4. EXCEEDS MINIMUM PERFORMANCE IS 0.49 INCH WC CLEAN FILTER LOSS WITH AN ADDITIONAL 0.35" DIRTY FILTER ALLOWANCE OUTDOOR AIR CAPABILITY, WITH RELIEF TO OCCUR AT ROOF HOOD. GROUNDING AND INTERGRAL VFD'S FOR SUPPLY AND EXHAUST FANS. REQURIED BY WASHINGTON STATE ENERGY CODE TABLE C403.2.3(1) OF 10.0 EER AND 10.1 IEER MECHANICAL ABBREVIATIONS MECHANICAL LEGEND GENERAL MECHANICAL NOTES AFF APPROX BOP CBBD CFM CLG CONC COND CONN CONST CONTR CHWS CHWR db DIA DIM DN DWG EA ELECT ENGR EQUIP ESP EXH FD FLR FPI FVM GA GAL GPM HP KW LB MAX MBH MECH ABOVE FINISHED FLOOR APPROXIMATE BOTTOM OF PIPE COUNTER BALANCED BACKDRAFT DAMPER CUBIC FEET/MINUTE CEILING CONCRETE CONDENSATE CONNECTION CONSTRUCTION CONTRACTOR CHILLED WATER SUPPLY CHILLED WATER RETURN DRY BULB DIAMETER DIMENSION DOWN DRAWING EXHAUST AIR ELECTRICAL ENGINEER EQUIPMENT EXTERNAL STATIC PRESSURE EXHAUST DEGREES FAHRENHEIT FLOOR DRAIN FLOOR FINS PER INCH FEET PER MINUTE FACE VELOCITY GAUGE GALLON GALLONS/MINUTE HORSEPOWER KILOWATT POUND MAXIMUM BTUH IN THOUSANDS MECHANICAL MFGR MIN NC NO 0/C OSWF OA PO PF PG PSIG PRESS RA RECIRC REG REQD RPM RM SA SP SPEC SQ SS STD STRUCT SW TD TEMP THRU TMTR TSP TSTAT TYP V VEL VD wb MANUFACTURER MINIMUM NORMALLY CLOSED NORMALLY OPEN ON CENTER ON -SITE WORK FORCE OUTSIDE AIR PRESSURE DIFFERENCE PLUG FAN PRESSURE GAUGE POUNDS/SQUARE INCH, GAUGE PRESSURE RETURN AIR RECIRCULATION REGISTER REQUIRED REVOLUTIONS/MINUTE ROOM SUPPLY AIR STATIC PRESSURE SPECIFICATIONS SQUARE STAINLESS S I LI.L STANDARD STRUCTURE, STRUCTURAL SWITCH TEMPERATURE DIFFERENCE TEMPERATURE THROUGH THERMOMETER TOTAL STATIC PRESSURE THERMOSTAT TYPICAL VENT VELOCITY MANUAL VOLUME DAMPER WASTE WET BULB (THROW) AP EF-4 O COND NEW DUCTWORK EXISTING DUCTWORK DEMOUTION DUCTWORK RA/EA RETURN AIR, REUEF AIR OR EXHAUST AIR DUCT / RISER SA SUPPLY AIR DUCT / RISER DUCT TURNIING DOWN NEW EQUIPMENT EXISTING EQUIPMENT CEILING MOUNTED RETURN OR EXHAUST GRILLE / REGISTER CEILING MOUNTED SUPPLY DIFFUSER SIDEWALL RETURN GRILLE ACCESS PANEL WALL MOUNTED THERMOSTAT WALL MOUNTED SPACE PRESSURE SENSOR MAJOR EQUIPMENT CALLOUT MINOR EQUIPMENT CALLOUT NOTE REFERENCE CONDENSATE CONTROL VALVE, MOTORIZED FLOOR DRAIN BUTTERFLY VALVE n n L � r =t= DN UP N DN UP Y-STRAINER BALL VALVE BALANCING VALVE EXISTING FIRE/SMOKE DAMPER MOTORIZED DAMPER VOLUME DAMPER COMBINATION FIRE/SMOKE DAMPER RADIUS OFFSET 90' HEEL TAP TAKEOFF (RECTANGULAR DUCT) TEE ECCENTRIC TRANSITION (A = 15' MAXIMUM) RECTANGULAR -TO -ROUND TRANSITION • (A = 15' MAXIMUM) DUCT OFFSET, DOWN DUCT OFFSET, UP MITERED ELBOW (WITH TURNING VANES) RADIUS ELBOW 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS, ELBOWS, ETC., WHICH MAY BE REQUIRED FOR PROPER INSTALLATION OF WORK. PROVIDE ADDITIONAL BENDS AND/OR OFFSETS AS REQUIRED TO COMPLETE WORK AT NO ADDITIONAL COST. 3. COORDINATION OF WORK WITH OTHER TRADES EMPLOYED IN THE PROJECT IS MANDATORY. CAREFULLY EXAMINE THE SPACE AVAILABLE TO DETERMINE FINAL ROUTING AND ELEVATIONS OF SERVICES. SHOULD REARRANGEMENT OR RE-ROUTING OF LINES OR PIPING BE NECESSARY, PROVIDE FOR APPROVAL THE SIMPLEST LAYOUT POSSIBLE FOR THAT PARTICULAR PORTION OF THE WORK. 4. THE EXISTENCE OF ANY PIPING, DUCTS OR OTHER SERVICE FACILITIES ARE SHOWN IN A GENERAL WAY ONLY. THE CONTRACTOR SHALL VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE OF ANY SUCH FACILITIES PRIOR TO THE SUBMISSION OF HIS BID. 5. CONTRACTOR TO REMOVE MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 6. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 7. ALL WORK TO BE INSTALLED PER CURRENT CENTURYLINK STANDARDS. REVIEWED FOR CODE _ E COMPLIANCE APPROVED AUG 2 8 2015 titit City of Tukwila BUILDING DIVISION ISSUES j REVISIONS NO. DESCRIPTION DATE 1 2 60% OWNER REVIEW 100% OWNER REVIEW 04/07/15 05/15/15 BY RJJ RJJ 3 BID SET 05/18/15 RJJ 4 PERMIT SET 08/11/15 RJJ 1600 7TH AVE., SEATRF, WASHINGTON OFRKCE OF THE O. PROPERTY MGM. 1 Wmrtla..ntrw r..r .a a &dosed b uoNwfmd pour. It is not Sr uu bycf Pritypit CONSULTANT FIRM KDWSAL SO'BRIEN 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p. 206547.1940 f. 206.547.8212 www.kdwnet 150241 e /t CenturyLink BUILDING ID RECEIVED CITY OF TUKWILA AUG 1 2 2015 PERMIT CENTER FLOOR BUILDING NAME TUKWILA CYBER CENTER STREET ADDRESS 6101 SOUTH 180TH STREET CITY, STATE TUKWILA, WA 98188 DRAWING INDEX DESCRIPTION MECHANICAL LEGEND AND NOTES MO.1 MECHANICAL LEGEND AND SCHEDULES M1.1 MECHANICAL DEMOLITION PARTIAL FLOOR PLAN M2.1 MECHANICAL PARTIAL FLOOR PLAN M2.2 MECHANICAL PARTIAL ROOF PLAN M5.1 MECHANICAL DETAILS AND DIAGRAMS CONSULTANT NAME KDW SALAS O'BRIEN CONSULTANT NAME DRAWN BY JCL DATE 04/07/15 CASE NUMBER JOB NO. 150241 R=1.5 x 0 CHECKED BY RJJ REVISED BY SCLE AS NOTED DRAWING NO. SHEET NO. MO.1 XFMR 6EN P4 500A I'kU5 PUGT 67 07 64 06 65 05 64 04 P3 L13 63 03 62. Si GI 61 GG Pi PI r62 L 6EN I I rED 6LI 4000A kJG PUGT AT5 GI 44 XFMR rPl 9=F 36/24 TT I UP TO 34/20 48/42 PLENUM ri-�--t- rat LF RTU-2 UP TO • RTU-4 • 36/24 36/24 24/24 LTF UP TO AC1 I • { rat f 72/40 CLEAR UVLNI 14/14 680 CFM EACH (TYP OF 59) I 160 220 ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-17 RTU —17 � \ I 24/24 rat r]_—C t EQUIPMENT ROOM } 66/28 (2" SL) UP TO RTU-17 160 220 240 220 1160 TYP 8� I 160 r7 240 220 t 30/18 TYPICL 160 L 180W\ TYPICAL l� 72/40 CLEAR OPENING ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-16 24/24 f t t f t t trt LOADING DOCK 12/12 18x16 1800 CFM STORAGE ROOM MEN t 66/28 (2" SL) UP TO RTU-16 MD-19 440 N 160 220 MD-18 440 600W DUCT LOOP BOD AT 16'-0" ABOVE SLAB. (14'-6" AFF) 0 t0 LOCKER BREAK ROOM WOMEN 0 n 4 + 16°"JY/r RTU —16 / { 600 f A.F.F. (TYP.) / / / 240 °/7"/"77, / COL°GATE ROOM t CORRIDOR 240 C c MECHANICAL DEMOLITION PARTIAL FLOOR PLAN SCALE: 1/8" = 1'-0" 0 4' 8' 16' PLAN NORTH REVIEWED FOR CODE COMPLIANCE APPROVED AUG 28 2015 City of Tukwila BUILDING DIVISION SHEET NOTES 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY ALL DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACIUTIES, ETC. NECESSARY TO COMPLETE THIS PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. 4. EXISTING INFORMATION SHOWN ON DRAWING HAS BEEN TAKEN FROM EXISTING DRAWINGS PROVIDED BY THE OWNER AND/OR CURSORY FIELD SKETCHES TAKEN FROM EXISTING FILED SKETCHES AND OBSERVATIONS. KDW SALAS O'BRIEN AND THEIR REPRESENTATIVES ARE NOT RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OR CONFORMANCE WITH CODES OF ANY WORK SHOWN AS EXISTING. 5. ALL TELECOMMUNICATIONS EQUIPMENT TO REMAIN ON—LINE AND FUNCTIONING AT ALL TIMES. CONTRACTOR TO PROTECT & MAINTAIN POWER TO ALL EQUIPMENT SCHEDULED TO REMAIN FOR THE DURATION OF CONSTRUCTION. 6. SCHEDULE ALL WORK OVER, NEAR OR AFFECTING NETWORK EQUIPMENT "METHODS WITH CENTURY LINK ON —SITE WORK FORCE PERSONNEL. COMPLETE OF PROCEDURE" FOR WORK AS DIRECTED BY AT&T IN ACCORDANCE WITH AT&T STANDARDS. 7. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 8. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 9. CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION, BRACING & SHORING OF EXISTING AND NEW EQUIPMENT OR MATERIALS UNTIL SUCH TIME IT IS PERMANENTLY SUPPORTED OR IS READY FOR REMOVAL DURING CONSTRUCTION, WHETHER SCHEDULED FOR DEMOLITION OR REUSE. 10. PROVIDE EQUIPMENT PROTECTION ABOVE ALL NETWORK EQUIPMENT (INCLUDING BUT NOT LIMITED TO CABLING, BUS, CABLE TRAY, EQUIPMENT BAYS, RECTIFIERS, BATTERIES, INVERTERS, DISTRIBUTION PANELS, ETC.). WHEN WORKING ABOVE EQUIPMENT, ALL PROTECTION SHALL BE COORDINATED WITH CENTURY UNK PERSONNEL TO ENSURE THAT THE PROTECTION WILL NOT BLOCK ACCESS TO EQUIPMENT OR CAUSE OVERHEATING. PROVIDE TEMPORARY COOUNG AS REQUIRED. CONTRACTOR TO SUBMIT DESIGN OF ALL TEMPORARY DUST BARRIERS TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. . © FLAG NOTES CONVERT SUPPLY PLENUM BELOW CEIUNG INTO EXHAUST. © REMOVE FSD, REF ARCH FOR INFILL OF WALL AND DEMOLITION OF GWB ENCLOSURE. 3 RECONNECT 24"0 TO EXHAUST, SEE M2.1. 10110- REMOVE EF-7 AT ROOF L DEMOUSH LOW WALL GRILL. 1010- REMOVE SHOWER, SEE M2.1 FOR NEW MOP SINK. ISSUES / REVISIONS NO. DESCRIPTION DATE BY 1 60% OWNER REVIEW 04/07/15 RJJ 2 100% OWNER REVIEW 05/15/15 RJJ 3 BID SET 05/18/15 RJJ 4 PERMIT SET 08/11/15 RJJ 1600 7TH AVE.. SEATII.E. WASHNGfON The llamas OFFICE OF THE DR PROPERTY MGMby m T. lhatid aastairl loin act to dry ems .L,.— CONSULTANT FIRM KDWSALASO'BRIEN ` ' 10202 Fifth Avenue NE, Suite 300 ( _ Seattle, Washington 98125 ::w. _ . v -- p. 206.547.1940 f. 206.547.8212 www.kdw.net 1�L J. .•'of,.ASi JO c`z� .' RECEIVED e4. CITY OF TUKWILA .0 3403' ' 11EGISTBR 10, w AUG 1 2 2015 SSIONAL '� �{ PERMIT: CENTER 150241 S �� `, ®fr BUILDING ID FLOOR �� `, BUILDING NAME TUKWILA CYBER CENTER 6101 SOUTH 180TH STREET s l'Itl ADDRESS Centu ry L i n k CRY, STATE TUKWILA, WA 98188 DESCRIPTION MECHANICAL DEMOLITION PARTIAL FLOOR PLAN CONSULTANT NAME CONSULTANT NAME KDW SALAS O'BRIEN DRAWN BY JCL CASE NUMBER JOB NO. DATE 04/07/15 150241 CHEC.• B'' J NG NO. SH EET NOTES 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY ALL DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. 0 XI=MR eEN L 0EN P4 500A 6UE, PU6T G7 07 GG 06 65 05 GA4 04 P3 LI3 63 03 62 02 GI el GG P2 PI T02 SLI 4000A PUGT AT5 GI XrMP. 15 Jr 34/20 J 48/42 PLENUM rat N) UP TO { 36/24 t RTU-2 UP TO LOADING DOCK • raL- 11=F 36/24 r� rim- rat RTU-4 12/12 EXTENDED TO WALL • 36/24 I I 18x16 1800 CFM UP TO AC1 { 24/24 72/40 CLEAR OPENI • ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-17 24/24 14/14 680 CFM EACH (TYP OF 59) { 160 220 ■ii�� TriT STORAGE ROOM MEN } } EQUIPMENT ROOM 66/28 (2" SL) UP TO RTU-17 RTU — 1 7 11. MEM 160 220 54x54 UP TO EXH FAN — 240 220 160 N r7 "mum .MIlii O 72/40 CLEAR OPENING ON TOP OF DUCT 36" CLR MIN ABOVE 72/27 (2" SL) UP TO RTU-16 24/24 66/28 (2" SL) UP TO RTU-16 MD-19I• 440 240 220 160 180W TY-ICAU 600W DUCT LOOP BOD AT 16'-0" ABOVE SLAB. A (14'-6" AFF) pm. IIIIIIii���l\ 160 BREAK ROOM MOPL JINKR-,`/\ TRANSITION 48"0 TO 36"0 22"0 (TYP) 220 0 4 1 Poc )- (TYP) 18"0 (e) 600 60x30 SO 60x30 RA UP 2400 c ... • MD-18 440 65x46 SA UP MD-20 C c • IFSD-1 POC 241'0 O I. -.I U 440� TRANSITION ��— 60 0 60"0 TO 48"0 �r D I 24"0 O 28"0 I ,� 48 0 36"0 COLLOCAT R M 24"0 O 28"0 WOMEN 0 14x14 14x14 SQUARE TO ROUND TRANSITION BA EYE IJ �24x 30x30 UP TO NEW EF-32 (WAS EF-7) r L, RTU — 1 6 -�-18"0 • CORRIDOR 54x54 UP TO EXH FAN PLAN NORTH REVIEVVED FOR CODE COMPLIANCE APPROVED 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOUTION, TEMPORARY CONSTRUCTION, TEMPORARY FACIUTIES, ETC. NECESSARY TO COMPLETE THIS PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. 4. EXISTING INFORMATION SHOWN ON DRAWING HAS BEEN TAKEN FROM EXISTING DRAWINGS PROVIDED BY THE OWNER AND/OR CURSORY FIELD SKETCHES TAKEN FROM EXISTING FILED SKETCHES AND OBSERVATIONS. KDW SALAS O'BRIEN AND THEIR REPRESENTATIVES ARE NOT RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OR CONFORMANCE WITH CODES OF ANY WORK SHOWN AS EXISTING. 5. ALL TELECOMMUNICATIONS EQUIPMENT TO REMAIN ON—LINE AND FUNCTIONING AT ALL TIMES. CONTRACTOR TO PROTECT & MAINTAIN POWER TO ALL EQUIPMENT SCHEDULED TO REMAIN FOR THE DURATION OF CONSTRUCTION. 6. SCHEDULE ALL WORK OVER, NEAR OR AFFECTING NETWORK EQUIPMENT WITH CENTURY LINK ON —SITE WORK FORCE PERSONNEL. COMPLETE "METHODS OF PROCEDURE" FOR WORK AS DIRECTED BY AT&T IN ACCORDANCE WITH AT&T STANDARDS. 7. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 8. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 9. CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION, BRACING & SHORING OF EXISTING AND NEW EQUIPMENT OR MATERIALS UNTIL SUCH TIME IT IS PERMANENTLY SUPPORTED OR IS READY FOR REMOVAL DURING CONSTRUCTION, WHETHER SCHEDULED FOR DEMOLITION OR REUSE. 10. PROVIDE EQUIPMENT PROTECTION ABOVE ALL NETWORK EQUIPMENT (INCLUDING BUT NOT LIMITED TO CABUNG, BUS, CABLE TRAY, EQUIPMENT BAYS, RECTIFIERS, BATTERIES, INVERTERS, DISTRIBUTION PANELS, ETC.). WHEN WORKING ABOVE EQUIPMENT, ALL PROTECTION SHALL BE COORDINATED WITH CENTURY UNK PERSONNEL TO ENSURE THAT THE PROTECTION WILL NOT BLOCK ACCESS TO EQUIPMENT OR CAUSE OVERHEATING. PROVIDE TEMPORARY COOUNG AS REQUIRED. CONTRACTOR TO SUBMIT DESIGN OF ALL TEMPORARY DUST BARRIERS TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. FLAG NOTES 32"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90.: CONICAL TAP 18"0, ACCUDUCT CT. 36"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90. 24"0 ELBOW DOWN TO SQ/RD TRANSITION AND 24x24 TITUS 350RL SUPPLY GRILLE, 2600 CFM. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. 32"0 TRANSITION TO 32x32 WITH FSD AND ELBOW TO BATTERY RM HIGH WALL SUPPLY. SEE DETAIL M5.1. REPLACE SUPPLY GRILLES WITH SCREENED OPENINGS, TYPICAL 4. 18"0 5 CORE 90 DEGREE ELBOW, ROUND TO SQUARE TRANSITION, 20x14 CONNECTION AT DADU CABINET. PROVIDE RUSKIN MD-35 VOLUME DAMPER. 44"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90. 65x46 UP THRU ROOF. PROVIDE 90 DEGREE RECT ELBOW WITH AIR FOIL TURNING VANES. RECTANGULAR TO ROUND TRANSITION, ACCUDUCT SQ RD. PROVIDE MOP SINK, FIAT MODEL TSBC1612, 36x36x12 INCH SIZE WITH MODEL 830AA SERVICE SINK FAUCET. EXTEND HOT AND COLD WATER FROM LOCATION OF EXISTING SHOWER. 22"0x18"0x18"0 TEE, DOWN TO, ROUND TO SQUARE TRANSITION, 20x14 CONNECTION AT DADU CABINET. 28"0 ELBOW DOWN TO SQ/RD TRANSITION AND 24x48 TITUS 350RL SUPPLY GRILLE, 5200 CFM. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. 28"0 DOWN TO SQ/RD TRANSITION AND 24x48 TITUS 350RL SUPPLY GRILLE. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. 18"0 DOWN TO SQ/RD TRANSITION AND PROVIDE 20x20 TITUS 350RL SUPPLY GRILLE, 1600 CFM. PROVIDE RUSKIN MD-35 VOLUME DAMPER IN RECTANGULAR DUCT ABOVE GRILLE. ISSUES / REVISIONS NO. DESCRIPTION DATE BY 1 2 3 60% OWNER REVIEW 100% OWNER REVIEW BID SET 04/07/15 05/15/15 05/18/15 RJJ RJJ RJJ 4 PERMIT SET 08/11/15 RJJ 1600 7TH NIL SFATRE, WAS I GTON OFFICE OF THE DR PROPERTY MGM The Mermen exteivel dettil sot be Adad if twaseetterd prom It Y inure for w by artlmfd ropfereikelfee d CrnbiyUsk CONSULTANT FIRM KDWSALASO'BRIEN 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p. 206.547.1940 f. 206.547.8212 www.kdw.net 150241 to % sr �` CenturyLink DESCRIPTION BUILDING ID .; • RECEIVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER FLOOR BUILDING NAME TUKWILA CYBER CENTER STREET ADDRESS 6101 SOUTH 180TH STREET CRY. STATE TUKWILA, WA 98188 MECHANICAL PARTIAL FLOOR PLAN CONSULTANT NAME KDW SALAS O'BRIEN CONSULTANT NAME MECHANICAL PARTIAL FLOOR PLAN SCALE: 1 /8" = 11-0" 0 4' 8' 16' AUG 28 2015 City of Tukwila BUILDING DIVISION DRAWN BY JCL CASE NUMBER JOB NO. SHEET NOTES 1. DO NOT SCALE THESE DRAWINGS. 2. VERIFY ALL DIMENSIONS & CONDITIONS IN THE FIELD. NOTIFY ENGINEER OF ANY DISCREPANCIES. (29'—O") (3I'-6") O 70A( r 7 T L J RAC \ / / \ RTU-1 /\ 70A< r 1 I N • L RA C 0 RTU- 5 30x30 DN 54x54 DN/ 0 Oo REVIEWED FOR CODE COMPLIANCE n APPROVED 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, ETC. NECESSARY TO COMPLETE THIS PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS. 4. EXISTING INFORMATION SHOWN ON DRAWING HAS BEEN TAKEN FROM EXISTING DRAWINGS PROVIDED BY THE OWNER AND/OR CURSORY FIELD SKETCHES TAKEN FROM EXISTING FILED SKETCHES AND OBSERVATIONS. KOW SALAS O'BRIEN AND THEIR REPRESENTATIVES ARE NOT RESPONSIBLE FOR THE ACCURACY OR ADEQUACY OR CONFORMANCE WITH CODES OF ANY WORK SHOWN AS EXISTING. 5. ALL TELECOMMUNICATIONS EQUIPMENT TO REMAIN ON-LINE AND FUNCTIONING AT ALL TIMES. CONTRACTOR TO PROTECT & MAINTAIN POWER TO ALL EQUIPMENT SCHEDULED TO REMAIN FOR THE DURATION OF CONSTRUCTION. 6. SCHEDULE ALL WORK OVER, NEAR OR AFFECTING NETWORK EQUIPMENT WITH CENTURY LINK ON -SITE WORK FORCE PERSONNEL. COMPLETE "METHODS OF PROCEDURE" FOR WORK AS DIRECTED BY AT&T IN ACCORDANCE WITH AT&T STANDARDS. 7. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE. 8. MAINTAIN AREAS FREE OF DEBRIS ACCUMULATION. KEEP WORK AREAS NEAT AND ORDERLY IN AS MUCH AS REASONABLY POSSIBLE. 9. CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION, BRACING & SHORING OF EXISTING AND NEW EQUIPMENT OR MATERIALS UNTIL SUCH TIME IT IS PERMANENTLY SUPPORTED OR IS READY FOR REMOVAL DURING CONSTRUCTION, WHETHER SCHEDULED FOR DEMOLITION OR REUSE. 10. PROVIDE EQUIPMENT PROTECTION ABOVE ALL NETWORK EQUIPMENT (INCLUDING BUT NOT LIMITED TO CABLING, BUS, CABLE TRAY, EQUIPMENT BAYS, RECTIFIERS, BATTERIES, INVERTERS, DISTRIBUTION PANELS, ETC.). WHEN WORKING ABOVE EQUIPMENT, ALL PROTECTION SHALL BE COORDINATED WITH CENTURY LINK PERSONNEL TO ENSURE THAT THE PROTECTION WILL NOT BLOCK ACCESS TO EQUIPMENT OR CAUSE OVERHEATING. PROVIDE TEMPORARY COOLING AS REQUIRED. CONTRACTOR TO SUBMIT DESIGN OF ALL TEMPORARY DUST BARRIERS TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. FLAG NOTES INSTALL RTU-16A ON STRUCTURAL STEEL APPROX 4 FEET ABOVE ROOF DECK. TRANSITION FROM 25x90 RA CONNECTION AT BOTTOM OF RTU TO 60x30 AT ROOF PENETRATION. PROVIDE R-12 RIGID EXTERIOR INSULATION ON OUTDOOR PORTION OF THE DUCT. PROVIDE R-12 RIGID EXTERIOR INSULATION AT OUTDOOR PORTION OF SA DUCT. PROVIDE 72x27 RA DAMPER (RUSKIN CD-60 PARALLEL BLADE) IN TA DUCT. MOUNT DIRECT COUPLED ACTUATOR IN EXTERIOR ENCLOSURE. ENLARGE THE EXISTING OA OPENING AND PROVIDE A 60x28 RUSKIN CD-60 PARALLEL BLADE OA DAMPER ON RTU EXTERIOR CONCEALED BY THE OA INTAKE HOOD. ISSUES / REVISIONS NO. DESCRIPTION DATE BY 1 60% OWNER REVIEW 04/07/15 RJJ 2 3 100% OWNER REVIEW BID SET 05/15/15 05/18/15 RJJ RJJ 4 PERMIT SET 08/11/15 RJJ 1600 7R1 AVE, SEATRE, WA HINGT0N OFFICE OF THE DR PROPERTY MGMT. Tie Womwla. a.dlwl Mel sheuel . t M ddawd b wodwrt d poem It w net far ow by adfwdsd npw..Mlb.e d t7oihryUdi CONSULTANT FIRM KDWSA ASO'BRIEN 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p. 206.547.1940 f. 206.547.8212 www.kdw.net RECEIVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER 150241 'I 1e CenturyLink BUILDING ID FLOOR BUILDING NAME TUKWILA CYBER CENTER tcttI ADDRESS 6101 SOUTH 180TH STREET CRY, STATE TUKWILA, WA 98188 DESCRIPTION MECHANICAL PARTIAL ROOF PLAN CONSULTANT NAME KDW SALAS O'BRIEN CONSULTANT NAME MECHANICAL PARTIAL ROOF PLAN SCALE: 1/8" = 1'-0" 0 4' 8' 16' PLAN NORTH AUG 282015 City of Tukwila BUILDING DIVISION JOB NO. EF-32 32"0 32x32 AIRFOIL DAMPER WITH MANUAL QUADRANT ACCESSIBLE FROM UD OF BATTERY ROOM 32x32 FSD ELBOW WITH AIRFOIL TURNING VANES D MOP SINK 32"0 5 GORE 90 DEGREE ELBOW, ACCUDUCT L90 32"0 SQUARE TO ROUND TRANSITION 32x32 LID ABOVE B(\TTERY RM L BATTERY RM SCREENED SUPPLY C AIR OPENING FIRE RATED ENCLOSURE, REF ARCH FLAG NOTES: INTENTION IS TO DUMP UP TO 6,000 CFM OF SUPPLY AIR INTO THE AISLE IN FRONT OF THE RECTIFIERS. ADJUST SCREENED OPENING SIZE AFTER WALL DEMOUTION DETERMINES AVAILABLE SPACE. SEE M2.1. MECHANICAL SECTION SCALE: 1/4" = 1'-0" 0 2' 4' 8' MECHANICAL DETAIL SCALE: NONE CUT BACK EXISTING ROOF MEMBRANE AND INSULATION 6" AROUND FINISHED CURB LOCATION. BUILDING TO REMAIN WEATHERTIGHT AT ALL TIMES. C CUT OPENING IN EXISTING METAL DECK. SEE STRUCTURAL. EXISTING ROOF TRUSS C 84" 1 JL EXHAUST FAN GREENHECK LBP54 EXHAUST FAN BASE EXHAUST FAN DETAIL SCALE: 1/2" = 1'-O" 1 JIL 0 T• 2' PREMANUFACTURED INSULATED CURB, SECURED PER STRUCT ROOF MEMBRANE PATCH UP AND OVER CURB RIGID INSUL TO MATCH EXISTING (AVERAGE R-23) STEEL ANGLES PER STRUCT TEMPERATURE SENSOR IN AIR STREAM ACCESS FROM ABOVE 4• 6,500 CFM 4. VFD EF-32 CT BATTERIES ,vex` 1 RECTIFIERS EF-38 VFD RTU-16A VFD RTU-16 VFD —❑MD-18 RTU-17 VFD --ciMD-19 td3 6,000 CFM 0 CO —LOCATE AREA 0 PCOR AREA FROM EAST SA MD-20 AIR FLOW DIAGRAM EF-39 T J 22 AC-1 RTU-4 RTU-2 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 28 2015 ISSUES /REVISIONS NO. DESCRIPTION DATE BY 1 60% OWNER REVIEW 04/07/15 RJJ 2 100% OWNER REVIEW 05/15/15 RJJ 3 BID SET 05/18/15 RJJ 4 PERMIT SET 08/11/15 RJJ 1600 7111 AL SEATMIE. WASHI NGTON OFFICE OF THE OR. PROPERTY MGMT. me ila.am. addled Min toil .d to Mord M uontarlad rows. It is mart far no I, aultiodzad "pmmdotm d adrift CONSULTANT FIRM IOW Sb a ASO'BRIEN 10202 Fifth Avenue NE, Suite 300 Seattle, Washington 98125 p. 206.547.1940 f. 206.547.8212 www.kdw.net 150241 . RECEIVED CITY OF TUKWILA AUG 12 2015 PERMIT CENTER S,rA 'I ®e CenturyLink DESCRIPTION BUILDING ID FLOOR BUILDING NAME TUKWILA CYBER CENTER STRIA ADDRESS 6101 SOUTH 180TH STREET CITY, STATE TUKWILA, WA 98188 MECHANICAL DETAILS AND DIAGRAMS CONSULTANT NAME KDW SALAS O'BRIEN CONSULTANT NAME DRAWN BY JCL CASE NUMBER SCALE: NONE City of Tukwila BUILDING DIVISION DATE