MECHANICAL PERMIT
2623049110
17310 SOUTHCENTER PKWY
Project Name: THAI MALI CUISINE
Permit Number: M15-0105
Issue Date: 8/21/2015
Permit Expires On: 2/17/2016
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
KIR TUKWILA 050 LLC
3333 NEW HYDE PARK RD #100 PO
C/O KIMCO REALTY CORP, NEW HYDE
PK, WA, 11042
HANK CHAU
1605 S 93RD ST UNIT E5 , SEATTLE,
WA, 98108
MUTUAL INDUSTRIES, INC.
1605 5 93RD ST #ES, SEATTLE, WA,
98108
MUTUAII041D5
Phone: (206) 355-5990
Phone: (206) 767-6647
Expiration Date: 2/25/2017
DESCRIPTION OF WORK:
REPLACE (2) EACH MAKE-UP AIR UNITS FOR KITCHEN HOOD SYSTEM
Valuation of Work: $6,000.00
Type of Work: REPLACEMENT
Fuel type: ELECT
Fees Collected: $272.02
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: HIGHLINE,TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2012
Permit Center Authorized Signature:
Date: S ')— I
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: ('S tZ (1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: ***MECHANICAL PERMIT CONDITIONS***
10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
11: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
12: Manufacturers installation instructions shall be available on the job site at the time of inspection.
13: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are
acceptable with the following concerns:
14: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking
appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen
exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood
shall be protected with an approved automatic fire -extinguishing system installed in accordance with this
code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other
equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96,
10.2.3)
15: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever
cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the
cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1)
16: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing
systems shall have fire department review and approval of drawings prior to installation or modification.
17: Local U.L. central station supervision is required. (City Ordinance #2437)
18: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
20: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type
cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a
Class K rated portable extinguisher. (IFC 904.11.5)
21: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
24: These plans were reviewed by Fire Marshal 51, if you have any questions please call 206-575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400 FIRE FINAL
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKW.
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. NI l 1 — 61 V
Project No.
Date Application Accepted: //�0� l I9-
Date Application Expires: -l/( 1T 1
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
U1King Co Assessor's Tax No.:
Site Address: / 73 /0 $ou7keeik-�74/i/r2ll 7UKl77�./ / 1t .'924e,R Suite Number: Floor:
ay
;me, Name: 7fa./ R�' ;me, leati/./falt7 New Tenant: ❑ Yes
PROPERTY OWNER
Name: e'Q K lri/Resa f (Pabe Avre)
�+7�1
Address: '`,,
YJ _c� /116/ 0 �//. "
' 'l�
7g6 7 C-
City: State: 0
Zip: 03
CONTACT PERSON — person receiving all project
communication
Name: l mk. � 1:_ ie'(_A
l7
Address:me 5 - 43 /d 5t Lliti fL L 5
City: �..,//, State: CV/4 Zip: Q�,�a g
l/6((_35-J�-J�`�9(l
Phone: Fax: �6 _761- 6_Ga /
Email:
//Mile (1 3990 akissa. ()OM
0
MECHANICAL CONTRACTOR INFORMATION
Company Name: /'.4/ iu / .
u U. ..� .� f//'e Zae
//
Address: /Gi/% �t, '3 fri. f Lipti f E y
City: �P l(i State: t h . Zip: gf/08
Phone: ze6_767-6641 Fax: �d6--767-662
Contr Reg No.A/i l/miz 044 05 Exp Date: 45/20/7
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 1,771D
Z r ach /if G/>Il /e
Describe the scope of work in detail:
k't ti4Q4 y
elktre
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric
Gas ❑ Other:
H:\Applications\Porms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGE T: j
Signature: (� Date: I/ �//s
Print Name: /JAi& Gd'MA Day Telephone: ?lg.
i 33-5 _9.i9i%
Mailing Address: (�i05 . o. 0-4cl-P( l'/lvif E •zNe
City
State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT QUANTITY
PermitTRAK
PAID
$272.02
M15-0105 Address: 17310 SOUTHCENTER PKWY Apn: 2623049110
$272.02
MECHANICAL
$261.56
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$176.75
PLAN CHECK FEE
R000.322.102.00.00
0.00
$52.31
TECHNOLOGY FEE
$10.46
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R5943
R000.322.900.04.00
0.00
$10.46
$272.02
Date Paid: Friday, August 14, 2015
Paid By: HIEN CHAU
Pay Method: CHECK 1340
Printed: Friday, August 14, 2015 1:51 PM 1 of 1
CSYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
Type/Inspection:
`
A dtd.23 /40 scnAge e„�/,`�i
Date Called:
Special Instructions:
Date Wanted:
7—/ -/
a.m.
p.m.
Requester:
Phone No:
Approved per applicable codes. Ll Corrections required prior to approval.
COMMENTS:
QA ft `?I..tJ
Inspector:
/1/4
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Operating Instructions & Parts Manual
4RNN6, 4RNN7, 4RNN8, 4RNP3, 4RNP4,
4RNP5, 4RNP1, 4RNP2, 4RNN9, 4RNR4,
4RNR2, 4RNP9, 4RNP7, 4RNR3, 4RNR1,
4RNP8, 4RNP6
Please read and save these instructions. Read carefullybefore attempting to assemble, instal4 operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in
personal injury andlorproperty damage! Retain instructions for future reference.
Dayton® FILE
Evaporative Coolers
Description
The Dayton® Evaporative Cooler is a natural way to condition the atmosphere. It cools by combining water
evaporation with air movement, through carefully designed and manufactured equipment, providing maximum
efficiency and safety. This air conditioning system, in addition to being economical, gives more benefits than
other air conditioning systems for homes and businesses. The system does not use refrigerants or compressors; it
cools by simply moving air through moist filters. Air temperature drops when a liquid, in this case water,
transforms into gas. Humidity is not perceived, since the air in the room is renewed approximately every two
minutes, providing a comfortable cooling effect. Continuous air circulation is a vital aspect of the cooling process
in this equipment, and gives it a distinct advantage over air conditioning by refrigeration.
Unpacking
Handle product carefully and check the packing Iist to account for all items. Visually inspect for shipping damage.
If damaged, immediately file a claim with the carrier.
Window Unit
4RNN8 / 4RNN7 / 4RNN6
REV/EWED FOR
ODE COMPLIANCE
APPROVED
AUG 21 2015
City of Tukwila
BUILDING DIVISb atad Unit -Side Discharge (CELDEK)
R4 / 4RNR2 / 4RNP9 / 4RNP7
Ducted Unit -Side Discharge
4RNP5 / 4RNP4 / 4RNP3
Ducted Unit -Down Discharge
4RNP2 / 4RNP1 / 4RNN9
RECEiVED
TY OF TUKWILA
AUG 1 4 2015
Ducted Unit -Down Discharge�'y" �- CENTER
4RNR3/4RNR1/4RNP8/4
Note: Filters not shown (wet media)
Form 556495
Printed in Mexico
09663
1109/223NCPVP
fNM100
Dayton
Operating Instructions & Parts Manual
4RNN6, 4RNN7, 4RNN8, 4RNP3, 4RNP4, 4RNP5,
4RNP1, 4RNP2, 4RNN9, 4RNR4, 4RNR2, 4RNP9,
4RNP7, 4RNR3, 4RNR1, 4RNP8, 4RNP6
Dayton®
Evaporative Coolers
Specifications:
4RNN8
Motor hp
(kw)
1/8 (0.093)
Volts (V)
120
Amperage
2.6
Frecuency
Hz
60
Phase
1
AWG Ga
16-18
Gross Weight
Pounds (Kg)
56.2 (25.5)
Tank Capacity
Gallons (liters)
6.3 (23.8)
4RNN7
1/3 (0.248)
120
6.5
60
1
16-18
81.6 (37)
10.4 (39.4)
4RNN6
1/2 (0.373)
120
8.5
60
1
16-18
126.1 (57.2)
15 (56.8)
4RNP5
1/3 (0.248)
120
6.5
60
1
16-18
79.4 (36)
10.4 (39.4)
4RNP2
1/3 (0.248)
120
6.5
60
1
16-18
88.6 (40.2)
7.7 (29.1)
4RNP4
1/2 (0:373)
120
8.5
60
1
16-18
15 (56.8)
123.5 (567"'"
4RNP7
1/2 (0.373)
120
8.5
60
1
16-18
134.9 (61.2)
11 (41.6)
4RNP3
3/4 (0.559)
120
10.5
60
1
16-18
170.2 (77.2)
17.8 (67.4)
4RNN9
3/4 (0.559)
120
10.5
60
1
16-18
181.2 (82.2)
12.7 (48.1)
4RNR4
3/4 (0.559)
120
10.5
60
1
16-18
143.3 (65)
9.3 (35.2)
4RNR3
3/4 (0.559)
120
10.5
60
1
16-18
143.3 (65)
9.3 (35.2)
4RNR2
1 (0.746)
120
12.3
60 -
1
16-18
169.8 (77)
9.3 (35.2)
4RNR1
1 (0.746)
120
12.3
60
1
16-18
169.8 (77)
9.3 (35.2)
4RNP9
3/4 (0.559)
120
10.5
60
1
16-18
143.3 (65)
9.3 (35.2)
4RNP8
3/4 (0.559)
120
10.5
60
1
16-18
143.3 (65)
9.3 (35.2)
4RNP7
1 (0.746)
120
12.3
60
1
16-18
169.8 (77)
9.3 (35.2)
Dimensions Table in:
Model
4RNN8
Discharge
Window
Transmission
Direct
Height (in)
27
Width (in)
22
Depth (in)
31
Cool Pad Type
Aspen
4RNN7
Window
Belt drive
28 1/4
28 1/4
38 3/16
Aspen
4RNN6
Window
Belt drive
35 1/4
34
43 1/2
Aspen
4RNP5
Side
Belt drive
28 1/4
28
28
Dry
4RNP2
Down
Belt drive
28 1/4
28
28
Dry
4RNP4''
Side
Belt drive
35 1/4
34
34
Dry
4RNP7
Down
Belt drive
35 1/4
34
34
Dry
4RNP3
Side
Belt drive
42 1/4
37
37
Dry
4RNN9
Down
Belt drive
42 1/4
37
37
Dry
4RNR4
Side
Belt drive
27 1/4
42
43
Celdek
4RNR3
Down
Belt drive
27 1/4
42
43
Celdek
4RNR2
Side
Belt drive
32 1/4
42
43
Celdek
4RNR1
Down
Belt drive
32 1/4
42
43
Celdek
4RNP9
Side
Belt drive
27 1/4
42
47
Celdek
4RNP8
Down
Belt drive
27 1/4
42
47
Celdek
4RNP7
Side
Belt drive
32 1/4
42
47
Celdek
4RNP6
Down
Belt drive
32 1/4
42
47
Celdek
2
Dayton
Technical Specs
• ItemDucted Evaporative Cooler
• DriveWith
• Air Flow4800 cfm
• Cooling Capacity1000 to 1400 sq. ft.
• Blade Dia.16"
• Drive TypeBelt
• Speed2
• Motor HPl/2
• Voltagell5
• Amps9.2
• DischargeSide
• Width34"
• Depth34"
• Height35-1/4"
• Duct Opening Length17-3/4"
• Duct Opening Width17-3/4"
• MediaSynthetic Fiber
• . Pad Thickness2"
• Pump Voltagel l5
• Water Connection3/4"
• Water Capacity15 gal.
• Fill TypeHose
• Operating Weight262.4 lb.
• MaterialWelded
• FinishPainted
• ColorCream
• IncludesPrinted Manual, Float, Hose Thread Overflow
PERMIT CORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M15-0105 DATE: 08/18/15
PROJECT NAME: THAI MALI CUISINE
SITE ADDRESS: 17310 SOUTHCENTER PKWY
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
c &te)crt. '6 C 0- S
Building ivision E�u�
Public Works
Fire Prevention
Structural
El
Planning Division
Permit Coordinator
❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 08/20/15
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required ❑ Denied
(ie: Zoning Issues)
(corrections entered in Reviews)
Notation:
Approved with Conditions
DUE DATE: 09/17/15
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
MUTUAL INDUSTRIES INC
Horne Inicio en Espanol Contact.
Page 1 of 2
Search L&I
A-Z Index .Help Mc Secure I.,&I.
Safety Claims & Insurance Workplace Rights Trades & Licensing
0 Washington State Department of
Labor & Industries
MUTUAL INDUSTRIES INC
Owner or tradesperson
Principals
CHAU, HIEN K, PRESIDENT
LUU, MAGGIE, SECRETARY
CHAU, ERIC
(End: 02/14/2011)
Doing business as
MUTUAL INDUSTRIES INC
WA UBI No.
601 526 728
1605 SOUTH 93RD ST #ES
SEATTLE, WA
206-767-6647
KING County
Business type
Corporation
Governing persons
ERIC
CHAU
HIEN KIEN CHAU;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
.........._..........................._.................................
Meets current requirements.
License specialties
GENERAL
License no,
MUTUAII041 D5
Effective — expiration
03/25/1996— 02/25/2017
Bond
................
CBIC
Bond account no.
SA1370
$12,000.00
Received by L&I Effective date
02/19/2002 02/20/2002
Expiration date
Until Canceled
Insurance
...................... _.......
Western National Assur Co $1,000,000.00
Policy no.
CPP1047435 04
Received by L&I Effective date
02/17/2015 02/22/2015
Expiration date
02/22/2016
Insurance history
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601526728&LIC=MUTUAII041D5&SAW= 8/21/2015