Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0111 - PURE WATER TECHNOLOGY - ROOFTOP PACKAGE HEAT PUMP
URE WATER TECHNOLOGY 12600 INTERURBAN AVE S M15-0111 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0004800003 Permit Number: M15-0111 12600 INTERURBAN AVE S PURE WATER TECHNOLOGY Issue Date: 9/21/2015 Permit Expires On: 3/19/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: GATEWAY OLYMPIA INC PO BOX 4900 #207 , SCOTTSDALE, WA, 85261 JESSE CHUTICH 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC 3202 C ST NE , AUBURN, WA, 98002 COMFOM1015LA Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2016 DESCRIPTION OF WORK: REPLACE ROOF MOUNTED PACKAGED HEAT PUMP LIKE FOR LIKE Valuation of Work: $5,908.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $272.02 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Date: q �J `-r I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: V /c— Print Name: Cfe55c- (1/. y/, l� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M C i� '- 0 1( I Project No. Date Application Accepted: 9)— C s -- Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION I Z `©0 a ve. S Site Address: I Z4OO .r r-I'e,rf.r14.r1 Tenant Name: King at/ P(4rt. Wafer TP nd1c,/ PROPERTY OWNER Name: G,t_i_Ct-/'Q 7/ ©I 0,64 tof I,vL rj,/DO Address: i T-el fer4r64n City: ,1 k ( < w(71 %4 State: v,4- Zip: a 8 f6 CONTACT PERSON — person receiving all project communication Name: Jesse Chutich Address: 3202 C ST NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: jesse@comfortmech.com Co Assessor's Tax No.: OoO qSO — 0003 Suite Number: 44 / 6 Q Floor: New Tenant: ❑ Yes ® .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Address: 3202 C ST NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOMI015LA Exp Date: 04/25/2016 Tukwila Business License No.: Qc,tS _p11.33 6s Valuation of project (contractor's bid price): $ r _` 09 Describe the scope of work in detail: Re p/c _ roof Pho.nf4.a1 pat. 41cJ 4.4e..1- P" p r late Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Pones-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/I,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Je 5 e~ (14 N 4I al Mailing Address: 3202- i cS-/- NI H:\Applications\Forms-Applications On Line\2011 Applications\Mcchanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 hh Day Telephone: Date: V24 1-12s-2T,-' 1Q A -41rr WA 11002 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $272.02 M15-0111 Address: 12600 INTERURBAN AVE S Apn: 0004800003 $272.02 MECHANICAL $261.56 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $176.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $52.31 TECHNOLOGY FEE $10.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6070 R000.322.900.04.00 0.00 $10.46 $272.02 Date Paid: Wednesday, September 02, 2015 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 512051 Printed: Wednesday, September 02, 2015 1:16 1 of 1 PM CRSYSTEMS 110INSPECTION RECORD Retain a copy with permit INSPECT! O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (06) 431 3670 Permit Inspection Request Line (206) 438-9350 (Q vj •.�.. Project: Pc(V€, War Ter,* Type of Inspection: V/ A-4 0 f`-t6 I Address: l 24oI) _Ttcht.r h ilite-id Date Called: - Special Instructions: MA R019b Hirk C3 Date Wante: C / T CJ_ ®— IT— a.m. p.m. Requester: Phone No: t 6OMMENTS: Approved per applicable codes. Corrections required prior to approval. NM- S.w de-t,e_ckoAi( 4 Ck.o,c4- t'frtft,t( 4410 tio,r Inspector: Date: `CY REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3T Pkg HP-Horiz Project: -Untitledl Prepared By: 07/31/2015 02:24PM 3T Pkg HP-Horiz Tag Cover Sheet Unit Report Certified Drawing Performance Report Ml5-'O(II REVIEWED FOR CODE COMPLIANCE APPROVED SEP 152015 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 0 2 2015 PERMIT CENTER Packaged Rooftop Builder 1.39r Page 1 of 6 Unit Report For 3T Pkg HP-Horiz Project:-Untitledl Prepared By: 07/31/2015 02:24PM Unit Parameters Unit Model* 50EZ-A36---5 Unit Size' 36 (3 Tons) Volts -Phase -Hertz* 208-3-60 Heating Type* Heat Pump Duct Cfg- Horizontal Supply / Horizontal Return Warranty Information 1 year warranty on parts 5 year warranty on compressor No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) *** Unit Length 4' 0.1875" Unit Width. 2' 8.625" Unit Height 3' 7.9375" *"" Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight 343 lb NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50EZ-A36---5 Rooftop Unit 1 Base Unit Accessories CPCRKHTROO8A00 240V Crankcase Heater 1 CPHEATER056A00 7.5/10.0 kW, 208/230-3-60 volt, Electric Heater 1 CPECOMZR010A00 Horizontal Economizer 1 CPRLYKIT001A00 Economizer relay kit for heat pumps 1 Packaged Rooftop Builder 1.39r Page 2 of 6 Certified Drawing for 3T Pkg HP-Horiz 0 .74 s. FRONT VIEW REAR VIEW 50E2500357 • 0 0 0 M U) m 0 Packaged Rooftop Builder 1.39r F Performance Summary For 3T Pkg HP-Horiz Project:-Untitledl Prepared By: 07/31/2015 02:24PM Part Number:50EZ-A36---5 ARI SEER' 13.50 Base Unit Dimensions Unit Length* 48.2 in Unit Width* 32.6 in Unit Height 43.9 in Total Operating Weight 343 lb Unit Unit Voltage -Phase -Hertz' 208-3-60 Air Discharge' Horizontal Fan Drive Type* Direct Actual Airflow* 1168 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB* 80.0 F Evaporator Entering Air WB 67.0 F Entering Air Enthalpy. 31.44 BTU/Ib Evaporator Leaving Air DB* 59.5 F Evaporator Leaving Air WB. 57.7 F Evaporator Leaving Air Enthalpy. 24.81 BTU/Ib Net Cooling Capacity' 34.86 MBH Net Sensible Capacity. 25.83 MBH Total Unit Power Input 3.03 kW Coil Bypass Factor 0.167 Heating Performance Outdoor Ambient Temperature' 47.0 F Entering Air Indoor Coil DB* 70.0 F Leaving Air Indoor Coil DB. 97.8 F Total Heating Capacity. 35.07 MBH Integrated Heating Capacity. 35.07 MBH Heating Power Input 3.02 kW High Temperature COP* 3.4 Low Temperature COP* 2.3 HSPF. 7.7 Electric Heating Capacity 7.50 kW Unit Leaving Air Temp. 118.1 F Supply Fan External Static Pressure:. 0.49 in wg Options / Accessories Static Pressure Electric Heaters 0.05 in wg Economiser. 0.23 in wg Wet Coil. 0.09 in wg Total Application Static (ESP + Unit Opts/Acc.) 0.86 in wg Fan Motor Size, hp. 3/4 NOTE Med-High Motor Speed, Horz Electrical Data Minimum Voltage- 197 Maximum Voltage. 253 Compressor RLA. 13 Compressor LRA. 73 Actual Electric Heater kW* 7.5 Electric Heater FLA* 20.8 Packaged Rooftop Builder 1.39r Page 4 of 6 Performance Summary For 3T Pkg HP-Horiz Project:-Untitled1 Prepared By: 07/31/2015 02:24PM Outdoor Fan FLA (ea)• 1.2 Indoor Fan Motor FLA' 6 Power Supply MCA' 49.5 Power Supply MOCP (Fuse or HACR)• 50 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating' 77.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 63.0 250 Hz NA NA 68.0 500 Hz NA NA 73.0 1000 Hz NA NA 71.0 2000 Hz NA NA 67.0 4000 Hz NA NA 62.0 8000 Hz NA NA 55.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground' 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground' 5.7 ft 4. Height of obstruction' 0.0 ft 5. Horizontal distance from obstruction to receiver' 0.0 ft 6. Horizontal distance from unit to obstruction' 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 0.0 63.0 68.0 73.0 71.0 67.0 62.0 55.0 76.8 Lw B - 26.2 46.9 59.4 69.8 71.0 68.2 63.0 53.9 75.0 LwA C 0.0 30.6 35.6 40.6 38.6 34.6 29.6 22.6 44.4 Lp D - 26.2 14.5 27.0 37.4 38.6 35.8 30.6 21.5 42.6 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA Packaged Rooftop Builder 1.39r Page 5 of 6 Performance Summary For 3T Pkg HP-Horiz Project:—Untitledl Prepared By: 07/31/2015 02:24PM C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.39r Page 6 of 6 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0111 DATE: 09/02/15 PROJECT NAME: PURE WATER TECHNOLOGY SITE ADDRESS: 12600 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: kl Building Division Public Works Nor AM cAll in Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/03/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/01/15 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) n n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Page 1 of 2 Hone Inicio en Espanol Contact Search L&I A-Z Index Help My Secure L,&I Safety Claims & Insurance Workplace Rights Trades & Licensing ashington State Department of Labor & Industries COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999— 04/25/2016 Bond Lexon Ins Co Bond account no. 9815017 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 06/04/2012 06101/2012 Expiration date Until Canceled Bond history Insurance .............................. Continental Western Ins Co $1,000,000.00 Policy no. CWP6015115 Received by L&I Effective date 05/27/2015 06/01/2015 Expiration date 06/01/2016 Insurance history Savin s https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 9/21/2015